364834-YTG-C-0708
DESCRIPTION
The 13 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG’s complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-on coils are available for use
with upflow, downflow, or horizontal furnaces and air han-
dlers.
WARRANTY
Single Phase Units:
TECHNICAL GUIDE
5-year limited parts warranty.
SPLIT-SYSTEM
AIR CONDITIONERS
10-year limited compressor warranty.
FEATURES
13 SEER – R-410A
• QUALITY CONDENSER COILS - The coil is constructed
of aluminum microchannel tubing and enhanced aluminum
fins for increased efficiency and corrosion protection.
MODELS:
• PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure, temperature, and
externally by a factory installed high pressure switch. This
is accomplished by the simultaneous operation of high
pressure relief valve and a temperature sensor which pro-
tects the compressor if undesirable operating conditions
occur. A liquid line filter-drier further protects the compres-
sor.
YCJD18 THRU 60
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, and a single panel covering the electrical con-
trols make for easy servicing of the unit.
ISO 9001
Certified Quality
Management System
LISTED
• SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
Due to continuous product improvement, specifications
are subject to change without notice.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
Additional rating information can be found at
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
364834-YTG-C-0708
Additional R-410A Charge / Orifice Size for Various Matched Systems
YCJD18
S41S1(H)
YCJD24
S41S1(H)
YCJD30
S41S1(H)
YCJD36
S41S1(H)
YCJD42
S41S1(H)
YCJD48
YCJD60
S41S1
Outdoor Unit
S41S1(H)
0.073 / 904
4 - 9
Required Orifice or TXV 1,2
Factory Charge, lbs-oz
0.048 / 902
3 - 3
0.055 / 902
3 - 13
0.061 / 907
3 - 14
0.065 / 903
4 - 9
0.075 / 903
4 - 5
0.087 / 905
5 - 6
Indoor Coil3,4
Additional Charge, Oz
48 + 0
–
–
–
–
–
–
–
FC/MC/PC/UC18A3X
902 + 0
–
–
–
–
–
48 + 0
–
–
–
–
–
–
FC/MC/PC/UC18B3X
FC/MC/PC32A3X
FC/MC/PC35B3X
FC/MC/PC35C3X
FC/MC/PC/UC36A3X
FC/MC/PC/UC36B3X
FC/MC/PC/UC36C3X
FC/MC/PC37A3X
FC/MC/PC43B3X
FC/MC/PC43C3X
FC/MC/PC/UC48C3X
FC/MC/PC/UC48D3X
FC/MC/PC/UC60D3X
FC/MC62D3X
902 + 0
–
–
–
–
–
–
–
55 + 4
902 + 4
55 + 4
902 + 4
55 + 4
902 + 4
55 + 0
902 + 0
55 + 0
902 + 0
55 + 0
902 + 0
55 + 4
902 + 4
55 + 4
902 + 4
55 + 4
902 + 4
–
61 + 0
–
–
–
–
–
907 + 0
–
–
–
–
–
61 + 0
–
–
–
–
–
907 + 0
–
–
–
–
–
61 + 0
–
–
–
–
–
907 + 0
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
61 + 2
65 + 0
–
–
–
–
907 + 2
903 + 0
–
–
–
–
61 + 2
65 + 0
75 + 0
–
–
–
907 + 2
903 + 0
903 + 0
–
–
–
61 + 2
65 + 0
75 + 0
–
–
–
907 + 2
903 + 0
903 + 0
–
–
–
–
65 + 8
75 + 2
73 + 4
–
–
–
–
903 + 8
903 + 2
904 + 4
–
–
–
–
65 + 8
75 + 2
73 + 4
–
–
–
–
903 + 8
903 + 2
904 + 4
–
–
–
–
–
–
73 + 0
87 + 0
–
–
–
–
–
904 + 0
905 + 0
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
87 + 4
–
–
–
–
–
905 + 4
48 + 0
–
–
–
–
–
HC18A3X
902 + 0
–
–
–
–
–
–
55 + 0
902 + 0
55 + 4
902 + 4
55 + 4
902 + 4
–
–
–
–
–
–
HC30A3X
–
–
–
–
–
61 + 0
907 + 0
61 + 2
907 + 2
–
–
–
–
HC36B3X
–
–
–
–
–
65 + 0
75 + 0
–
HC42C3X
–
903 + 0
903 + 0
–
–
–
–
87 + 0
HC60D3X
–
–
–
–
–
905 + 0
48 + 0
–
–
–
–
–
–
–
–
–
–
–
–
–
AHP18B3X
902 + 0
–
–
–
–
–
–
–
–
–
55 + 4
902 + 4
–
61 + 0
907 + 0
61 + 2
907 + 2
–
–
–
AHP30B3X
–
–
–
65 + 0
903 + 0
65 + 0
903 + 0
AHP36C3X
–
–
–
75 + 0
903 + 0
AHP42C3X
–
–
Johnson Controls Unitary Products
3
364834-YTG-C-0708
Additional R-410A Charge / Orifice Size for Various Matched Systems (Continued)
YCJD18
S41S1(H)
YCJD24
S41S1(H)
YCJD30
S41S1(H)
YCJD36
S41S1(H)
YCJD42
S41S1(H)
YCJD48
S41S1(H)
YCJD60
S41S1
Outdoor Unit
Required Orifice or TXV 1,2
Factory Charge, lbs-oz
0.048 / 902
3 - 3
0.055 / 902
3 - 13
0.061 / 907
3 - 14
0.065 / 903
4 - 9
0.075 / 903
4 - 5
0.073 / 904
4 - 9
0.087 / 905
5 - 6
Indoor Coil3,4
Additional Charge, Oz
–
–
–
–
–
73 + 0
87 + 0
AHP/SHP60D3X
–
–
–
–
–
904 + 0
905 + 0
–
55 + 4
61 + 2
65 + 0
–
–
–
AV36C3X
–
902 + 4
907 + 2
903 + 0
–
–
–
–
–
–
–
–
73 + 0
–
AV/SV48D3X
AV60D3X
–
–
–
–
–
904 + 0
–
–
–
–
–
–
–
87 + 0
–
–
–
–
–
–
905 + 0
48 + 0
–
–
–
–
–
–
–
See Cautionbelow
F4FP024
902 + 0
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
55 + 0
–
–
–
–
–
See Cautionbelow
F4FP036
902 + 0
–
–
–
–
–
–
–
–
–
–
–
–
–
61 + 0
–
–
–
–
–
See Cautionbelow
F4FP040
907 + 0
–
–
–
–
–
–
–
–
–
65 + 8
75 + 2
73 + 4
904 + 4
73 + 0
904 + 0
73 + 0
904 + 0
–
See Cautionbelow
F5FP048
903 + 8
903 + 2
–
–
–
–
–
–
–
–
–
87 + 0
905 + 0
87 + 0
905 + 0
See Cautionbelow
F5FP060
See Cautionbelow
F4FV060
FOOTNOTES:
1. For applications requiring a TXV use 1TVM900 series kit.
2. Approved orifice shipped with outdoor unit.
3. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit
2FD06700224.
4. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of inter-
connecting line tubing.
2. Verify the TXV or orifice and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical
Data Table.
4. For TXV match charge weight needs to be weighed in for specififc coil match and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for
evaporator + adder for line set.
Models 12-48 require start kits for TXV matches. Models with “H” on the end of the model number have factory installed start kits.
For models without an “H” refer to tech guide for kit number reference.
F*FP Air Handlers come with a factory installed R-22 TXV which MUST BE CHANGED OUT to R-410A TXV or an orifice for proper opera-
tion. If the TXV is not changed out system damage will occur.
4
Johnson Controls Unitary Products
364834-YTG-C-0708
COOLING CAPACITY - With Air Handler Coils
AIR HANDLER
COOLING
NET MBH
COIL
MODEL1
UNIT
MODEL
RATED
CFM
MODEL
W
SEER
EER
TOTAL
SENS.
13 SEER AC WITH MA
YCJD18S41S1(H)
YCJD24S41S1(H)
MA08B
MA08B
MA08B
MA08B
MA12B
MA12B
MA12B
MA14D
MA16C
MA14D
MA16C
MA16C
MA20D
MA16C
MA20D
MA20D
MA20D
17
17
17
17
17
17
17
24
21
24
21
21
24
21
24
24
24
FC/MC18B
FC/MC36B
FC/MC35B
FC/MC43B
FC/MC35B
FC/MC43B
FC/MC43B
FC/MC48D
FC/MC43C
FC/MC48D
FC/MC48C
FC/MC48C
FC/MC48D
FC60C
600
17.5
24.0
24.0
24.0
29.0
29.0
35.0
35.0
42.0
42.0
42.0
48.0
48.0
48.0
48.0
57.0
57.0
12.9
16.7
16.7
16.7
21.0
21.0
24.8
24.8
29.2
29.2
29.2
34.4
34.4
34.4
34.4
38.5
38.5
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
800
800
800
1000
1000
1200
1200
1400
1400
1400
1600
1600
1600
1600
1800
1800
YCJD30S41S1(H)
YCJD36S41S1(H)
YCJD42S41S1(H)
YCJD48S41S1(H)
YCJD60S41S1
FC/MC60D
FC/MC60D
FC/MC62D
13 SEER AC WITH MV - VARIABLE SPEED
YCJD18S41S1(H)
YCJD24S41S1(H)
MV12B
MV12B
MV12B
MV12B
MV12B
MV16C
MV12B
MV16C
MV16C
MV16C
MV20D
MV12D
MV16C
MV16C
MV20D
MV16C
MV20D
MV20D
MV20D
MV20D
17
17
17
17
17
21
17
21
21
21
24
24
21
21
24
21
24
24
24
24
FC/MC18B
FC/MC36B
FC/MC35B
FC/MC43B
FC/MC35B
FC/MC35C
FC/MC43B
FC/MC43C
FC/MC43C
FC/MC48C
FC/MC48D
FC/MC48D
FC/MC43C
FC/MC48C
FC/MC48D
FC/MC48C
FC/MC48D
FC/MC60D
FC/MC60D
FC/MC62D
600
800
17.5
24.0
24.0
24.0
29.0
30.0
29.0
30.0
36.0
36.0
36.0
35.0
42.0
42.0
42.0
48.0
48.0
48.0
57.0
57.0
13.3
17.4
17.4
17.3
21.6
21.6
21.6
21.6
25.4
25.4
25.6
25.4
30.0
30.0
30.0
35.0
35.0
35.0
38.5
38.5
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
13.50
13.50
14.00
13.50
13.50
13.50
13.00
13.00
12.50
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
11.00
11.00
800
800
1000
1000
1000
1000
1200
1200
1200
1135
1400
1400
1400
1600
1600
1600
1800
1800
YCJD30S41S1(H)
YCJD36S41S1(H)
YCJD42S41S1(H)
YCJD48S41S1(H)
YCJD60S41S1
13 SEER AC WITH AV / SV / F*FV - VARIABLE SPEED
YCJD24S41S1(H)
YCJD30S41S1(H)
YCJD36S41S1(H)
AV36
AV36
21
21
21
24
24
24
24
24
–
–
–
–
–
–
–
–
765
24.0
30.0
35.0
48.0
48.0
48.0
58.0
57.0
17.4
21.8
25.2
35.0
35.0
34.4
39.0
38.5
14.00
14.00
14.00
13.50
13.50
14.00
13.50
13.50
12.00
12.00
12.00
12.00
12.00
11.50
11.00
11.00
1015
1270
1610
1655
1600
1765
1780
AV36
AV/SV48
AV/SV60
F4FV060
AV/SV60
F4FV060
YCJD48S41S1(H)
YCJD60S41S1
For Notes See Page 6.
Johnson Controls Unitary Products
5
364834-YTG-C-0708
COOLING CAPACITY - With Air Handler Coils (Continued)
AIR HANDLER
COOLING
NET MBH
COIL
MODEL1
UNIT
MODEL
RATED
CFM
MODEL
W
SEER
EER
TOTAL
SENS.
13 SEER AC WITH AHP / SHP / F*FP
AHP18
F4FP024
AHP30
17
18
17
21.5
17
21
18
21
21
24
21
24
24
24
24
24
24
24
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
650
600
17.5
17.5
24.0
24.0
29.0
29.0
29.0
35.0
35.0
35.0
41.0
41.0
48.0
48.0
48.0
48.0
57.0
57.0
12.9
12.9
16.8
16.7
21.0
21.0
21.0
24.8
24.8
24.8
29.2
29.2
34.4
35.0
34.4
34.4
38.5
38.5
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.50
13.00
13.00
13.00
13.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
YCJD18S41S1(H)
YCJD24S41S1(H)
795
F4FP036
AHP30
800
1015
1040
1050
1235
1255
1235
1485
1455
1675
1600
1600
1600
1850
1900
YCJD30S41S1(H)
AHP36
F4FP040
AHP36
YCJD36S41S1(H)
YCJD42S41S1(H)
AHP42
F5FP048
AHP42
F5FP048
AHP/SHP48
AHP/SHP60
F5FP048
F5FP060
AHP/SHP60
F5FP060
YCJD48S41S1(H)
YCJD60S41S1
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
6
Johnson Controls Unitary Products
364834-YTG-C-0708
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
FURNACE**
COOLING
COIL
MODEL
NET MBH
UNIT MODEL
CFM RANGE
(Min.-max.)
RATED
CFM
W
SEER1
EER
TOTAL
17.5
17.5
17.5
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
29.0
29.0
29.0
29.0
29.0
29.0
35.0
35.0
35.0
35.0
35.0
42.0
42.0
42.0
42.0
48.0
48.0
48.0
48.0
48.0
57.0
57.0
57.0
57.0
SENS.
12.9
12.9
12.9
16.7
16.7
16.7
16.7
16.7
16.7
16.7
16.7
16.7
21.0
21.0
21.0
21.0
21.0
21.0
24.8
24.8
24.8
24.8
24.8
29.2
29.2
29.2
29.2
34.4
34.4
34.4
34.4
34.4
38.5
38.5
38.5
38.5
450 - 750
450 - 750
14,17
14
FC/MC/PC18
HC18
600
600
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
11.00
YCJD18S41S1(H)
450 - 750
14,17
14
UC18
600
600 - 1000
600 - 1000
600 - 1000
600 - 1000
600 - 1000
600 - 1000
600 - 1000
600 - 1000
600 - 1000
800 - 1200
800 - 1200
800 - 1200
800 - 1200
800 - 1200
800 - 1200
1000 - 1400
1000 - 1400
1000 - 1400
1000 - 1400
1000 - 1400
1200 - 1600
1200 - 1600
1200 - 1600
1200 - 1600
1400 - 1800
1400 - 1800
1400 - 1800
1400 - 1800
1400 - 1800
1600 - 2000
1600 - 2000
1600 - 2000
1600 - 2000
FC/MC/PC32
FC/MC/PC35
FC/MC/PC36
FC/MC/PC37
FC/MC/PC43
HC30
800
17,21
14,17,21
14
800
800
800
YCJD24S41S1(H)
17,21
14
800
800
17
HC36
800
21
HC42
800
14,17,21
14
UC36
800
FC/MC/PC32
FC/MC/PC35
FC/MC/PC37
FC/MC/PC43
HC36
1000
1000
1000
1000
1000
1000
1200
1200
1200
1200
1200
1400
1400
1400
1400
1600
1600
1600
1600
1600
1800
1800
1800
1800
17,21
14
YCJD30S41S1(H)
17,21
17
21
HC42
14
FC/MC/PC37
FC/MC/PC43
FC/MC/PC48
HC42
17,21
21,24
21
YCJD36S41S1(H)
YCJD42S41S1(H)
YCJD48S41S1(H)
YCJD60S41S1
21,24
17,21
21,24
21
UC48
FC/MC/PC43
FC/MC/PC48
HC42
21,24
21,24
21,24
24
UC48
FC/MC/PC48
FC/MC/PC60
HC60
21,24
21,24
21,24
24
UC48
UC60
FC/MC/PC60
FC/MC62
HC60
24
21,24
UC60
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
** Refer to Quick Selection Chart for specific furnace match-up.
Johnson Controls Unitary Products
7
364834-YTG-C-0708
COOLING CAPACITY - With Variable Speed Furnaces
COOLING
Net MBH
VARIABLE SPEED
FURNACE MODEL
COIL
UNIT MODEL
W
RATED
CFM
MODEL1
SEER
EER
TOTAL
SENS.
13 SEER AC WITH VARIABLE SPEED FURNACES2
PV8*A12
PV9*A12
FC/MC/PC18A
FC/MC/PC18A
FC/MC/PC18B
HC18
14
14
17
14
14
14
14
17
14
14
17
14
14
17
14
14
17
14
14
17
17
21
21
21
21
14
14
17
17
21
21
21
21
17
17
21
21
21
21
14
14
17
17
21
21
21
21
21
600
625
17.5
17.5
17.5
17.5
17.5
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
29.0
29.0
29.0
29.0
30.0
29.0
29.0
29.0
29.0
30.0
29.0
29.0
30.0
29.0
29.0
29.0
29.0
29.0
30.0
29.0
29.0
29.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
35.0
36.0
13.4
13.3
13.3
13.4
13.3
17.3
17.1
17.2
17.3
17.2
17.2
17.2
17.2
17.2
17.3
17.1
17.2
21.6
21.4
21.6
21.6
21.8
21.4
21.6
21.6
21.6
21.4
21.6
21.6
21.8
21.4
21.6
21.6
21.6
21.6
21.8
21.4
21.6
21.6
25.0
25.0
25.2
25.2
25.4
25.2
25.2
25.2
25.4
14.00
14.00
14.00
14.00
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
13.50
14.00
14.00
13.50
14.00
14.00
14.00
13.50
14.00
14.00
14.00
13.50
14.00
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
13.50
14.00
14.00
13.00
13.00
13.50
13.50
14.00
13.50
13.50
13.50
14.00
12.50
12.50
12.50
12.50
12.50
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
11.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
11.00
12.00
12.00
12.00
12.00
12.00
11.00
12.00
12.00
12.00
11.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
YCJD18S41S1(H)
P(C,V)9*B12
PV8*A12
620
600
PV9*A12
HC18
625
PV8*A12
FC/MC/PC32A
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC36A
FC/MC/PC36A
FC/MC/PC36B
FC/MC/PC37A
FC/MC/PC37A
FC/MC/PC43B
HC30
750
PV9*A12
800
P(C,V)9*B12
PV8*A12
820
750
PV9*A12
800
P(C,V)9*B12
PV8*A12
820
YCJD24S41S1(H)
750
PV9*A12
800
P(C,V)9*B12
PV8*A12
820
750
PV9*A12
HC30
800
P(C,V)9*B12
PV8*A12
HC36
820
FC/MC/PC32A
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC37A
FC/MC/PC37A
FC/MC/PC43B
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
HC36
975
PV9*A12
1000
1050
975
PV8*B16
P(C,V)9*B12
PV8*C16
1000
1120
1010
1045
975
PV8*C20
P(C,V)9*C16
P(C,V)9*C20
PV8*A12
PV9*A12
1000
1050
975
PV8*B16
YCJD30S41S1(H)
P(C,V)9*B12
PV8*C16
1000
1120
1010
1045
1050
975
PV8*C20
P(C,V)9*C16
P(C,V)9*C20
PV8*B16
P(C,V)9*B12
PV8*C16
HC36
HC42
1000
1120
1010
1045
1185
1200
1200
1185
1200
1200
1175
1195
1200
PV8*C20
HC42
P(C,V)9*C16
P(C,V)9*C20
PV8*A12
HC42
HC42
FC/MC/PC37A
FC/MC/PC37A
FC/MC/PC43B
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
PV9*A12
PV8*B16
P(C,V)9*B12
PV8*C16
YCJD36S41S1(H)
PV8*C20
P(C,V)9*C16
P(C,V)9*C20
PV8*C16
For Notes See Page 9.
8
Johnson Controls Unitary Products
364834-YTG-C-0708
COOLING CAPACITY - With Variable Speed Furnaces (Continued)
COOLING
Net MBH
VARIABLE SPEED
FURNACE MODEL
COIL
UNIT MODEL
W
RATED
CFM
MODEL1
SEER
EER
TOTAL
SENS.
13 SEER AC WITH VARIABLE SPEED FURNACES2
PV8*C20
P(C,V)9*C16
P(C,V)9*C20
P(C,V)9*D20
PV8*C16
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48D
HC42
21
21
21
24
21
21
21
21
17
21
21
21
21
21
21
21
24
21
21
21
21
21
21
21
21
24
21
21
21
21
24
21
21
24
21
21
24
1200
1175
1195
1220
1200
1200
1175
1195
1400
1400
1415
1370
1400
1400
1415
1370
1360
1400
1400
1415
1370
1500
1610
1600
1580
1560
1500
1610
1600
1580
1560
1730
1650
1620
1730
1650
1620
35.0
35.0
35.0
35.0
36.0
35.0
35.0
35.0
42.0
42.0
42.0
42.0
42.0
42.0
42.0
42.0
42.0
42.0
42.0
42.0
42.0
47.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
57.0
56.0
56.0
57.0
56.0
56.0
25.2
25.4
25.2
25.4
25.4
25.2
25.2
25.2
29.6
29.8
29.6
29.8
29.6
29.8
29.6
29.8
30.0
29.6
29.8
29.6
29.8
34.6
34.6
34.4
34.6
35.0
34.6
34.6
34.4
34.6
35.0
38.0
39.0
39.0
38.0
39.0
39.0
13.50
14.00
14.00
14.00
14.00
13.50
14.00
13.50
13.00
13.50
13.00
13.50
13.50
13.50
13.00
13.50
13.50
13.00
13.50
13.00
13.50
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
11.00
12.00
12.00
12.00
11.00
12.00
12.00
12.00
12.00
11.00
12.00
11.00
11.00
11.00
11.00
12.00
11.00
11.00
11.00
11.00
12.00
11.00
11.00
11.00
11.00
11.00
11.00
YCJD36S41S1(H)
PV8*C20
HC42
P(C,V)9*C16
P(C,V)9*C20
PV8*B16
HC42
HC42
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48D
HC42
PV8*C20
P(C,V)9*C16
P(C,V)9*C20
PV8*C16
PV8*C20
YCJD42S41S1(H)
P(C,V)9*C16
P(C,V)9*C20
P(C,V)9*D20
PV8*C16
PV8*C20
HC42
P(C,V)9*C16
P(C,V)9*C20
PV8*C16
HC42
HC42
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48D
FC/PC60C
PV8*C20
P(C,V)9*C16
P(C,V)9*C20
P(C,V)9*D20
PV8*C16
YCJD48S41S1(H)
PV8*C20
FC/PC60C
P(C,V)9*C16
P(C,V)9*C20
P(C,V)9*D20
PV8*C20
FC/PC60C
FC/PC60C
FC/MC/PC60D
FC/PC60C
P(C,V)9*C20
P(C,V)9*D20
PV8*C20
FC/PC60C
FC/MC/PC60D
FC/MC62D
FC/MC62D
FC/MC62D
YCJD60S41S1
P(C,V)9*C20
P(C,V)9*D20
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.
Johnson Controls Unitary Products
9
364834-YTG-C-0708
ROOM THERMOSTATS - A wide selection of compatible
thermosets are available to provide optimum performance
and features for any installation.
ACCESSORIES
Refer to Price Manual for specific model numbers.
HARD START KIT - Required when using TXV indoor coil.
Also, provides increased starting torque for areas with low
voltage.
1H/1C, manual changeover electronic non-programmable
thermostat.
1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.
Model
18
Source 1 Kit numbers
S1-2SA06708606
S1-2SA06721706
S1-2SA06705906
S1-2SA06708906
S1-2SA06708806
S1-2SA06708806
S1-2SA06707906
1H/1C, auto/manual changeover, electronic programmable.
24
* For the most current accessory information, refer to the
price book or consult factory.
30
36
SOUND POWER RATINGS*
42
48
UNIT MODEL
(dBA)
75
60
18
24
30
36
42
48
60
76
OFF CYCLE TIMER DELAY - Provides a 5-minute off cycle
to prevent rapid recycling of the compressor.
76
76
76
77
TBD
* Rated in accordance with ARI 270-95 Standards.
TYPICAL INSTALLATION
MINIMUM 18” SERVICE
ACCESS CLEARANCE
ON ONE SIDE
THERMOSTAT
60” OVERHEAD
CLEARANCE
WEATHERPROOF
DISCONNECT
SWITCH
NEC CLASS 1 WIRING
6” CLEARANCE
AROUND PERIMETER
TO FURNACE OR
AIR HANDLER
TERMINAL BLOCK
NEC CLASS 2 WIRING
TO INDOOR COIL
NOTE:
ALL OUTDOOR WIRING
MUST BE WEATHERPROOF.
CONTROL
ACCESS
PANEL
SEAL OPENING(S) WITH
PERMAGUM OR EQUIVALENT
TYPICAL FIELD WIRING
ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES
POWER WIRING
CONTROL WIRING
FACTORY WIRING
POWER WIRING
208/230-1-60
24 VOLT CONTROL WIRING
MINIMUM 18 GA. WIRE
(NEC CLASS 2)
FURNACE OR AIR HANDLER TERMINAL BLOCK
Y R G W
C
*
TERMINAL W IS ONLY
REQUIRED ON SYSTEMS
WITH HEAT.
CONTACTOR
TERMINALS
GND.
LUG
*
COIL
R
Y
G
W
ROOM THERMOSTAT
CONDENSING UNIT
ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.
10
Johnson Controls Unitary Products
364834-YTG-C-0708
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
YCJD18S41S1(H)
INDOOR COIL MODEL NO.
FC/MC/PC18
IDCFM
ID DB (°F) 80
ID WB (°F) 57
450
75
600
75
750
CONDENSING
ENTERING AIR
TEMPERATURE
80
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
75
62
80
67
80
72
62
62
T.C.
S.C.
KW
15.7 17.8 17.7 19.3 19.9 16.9 18.4 18.0 19.5 20.2 18.0 18.9 18.4 19.6 20.4
16.0 13.8 12.1 12.0 9.3 17.3 15.9 13.5 13.0 9.8 18.5 17.9 14.9 13.9 10.4
65
75
1.0
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
T.C.
S.C.
KW
15.0 16.8 16.6 18.4 19.2 16.2 17.5 17.1 18.6 19.4 17.4 18.2 17.5 18.8 19.6
15.3 13.6 11.7 11.6 8.9 16.6 15.6 13.2 12.8 9.6 17.9 17.6 14.7 13.9 10.3
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
T.C.
S.C.
KW
14.2 15.8 15.6 17.4 18.5 15.5 16.6 16.1 17.7 18.6 16.8 17.4 16.7 18.1 18.8
14.5 13.4 11.2 11.2 8.6 15.9 15.3 12.8 12.6 9.4 17.2 17.2 14.4 13.9 10.1
85
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
T.C.
S.C.
KW
13.5 14.8 14.6 16.4 17.7 14.8 15.7 15.2 17.5 17.9 16.1 16.6 15.8 17.3 18.0
13.8 13.1 10.8 10.7 8.2 15.2 15.0 12.5 12.4 9.1 16.6 16.9 14.2 14.0 10.0
95
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
T.C.
S.C.
KW
12.6 13.7 13.2 15.1 16.5 13.8 14.6 13.8 15.5 16.7 15.0 15.5 14.4 16.0 16.8
12.8 12.5 10.2 10.3 7.9 14.1 14.1 11.8 11.9 8.8 15.4 15.7 13.4 13.6 9.8
105
115
125
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
T.C.
S.C.
KW
11.6 12.6 11.8 13.8 15.4 12.7 13.5 12.5 14.2 15.5 13.8 14.5 13.1 14.6 15.6
11.9 11.9 9.6
1.6 1.6 1.6
9.8
1.6
7.6 13.1 13.2 11.2 11.6 8.6 14.3 14.6 12.7 13.3 9.6
1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6
T.C.
S.C.
KW
10.7 11.4 10.5 12.5 14.2 11.7 12.4 11.2 12.9 14.3 12.7 13.4 11.8 13.3 14.4
11.0 11.2 9.0
1.8 1.8 1.8
9.4
1.8
7.3 12.1 12.3 10.5 11.2 8.3 13.1 13.5 12.0 12.9 9.4
1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler
–
Coil
T.C.
1.00
1.00
1.00
1.02
1.00
1.00
S.C.
1.00
1.00
1.00
1.03
1.00
1.00
KW
1.00
1.00
1.00
0.89
1.00
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
HC18
PV8*A12
PV9*A12
P(C,V)9*B12
PV8*A12
PV9*A12
FC/MC/PC18A
FC/MC/PC18A
FC/MC/PC18B
HC18
1.02
1.01
1.02
1.02
1.01
1.03
1.03
1.03
1.03
1.03
0.89
0.88
0.89
0.89
0.88
–
UC18
AHP18
MV12B
MA08B
F4FP024
–
FC/MC18B
FC/MC18B
–
HC18
Johnson Controls Unitary Products
11
364834-YTG-C-0708
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
YCJD24S41S1(H)
INDOOR COIL MODEL NO.
FC/MC/PC36
IDCFM
ID DB (°F) 80
ID WB (°F) 57
600
75
800
75
1000
75
CONDENSING
ENTERING AIR
TEMPERATURE
80
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
80
67
80
72
62
62
62
T.C.
S.C.
KW
22.0 27.4 27.3 29.1 30.3 24.3 28.8 28.6 30.4 31.7 26.6 30.1 29.8 31.8 33.2
22.0 19.9 17.3 17.0 13.8 24.2 22.9 19.6 18.8 14.8 26.4 26.0 22.0 20.6 15.7
65
75
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
T.C.
S.C.
KW
20.5 25.3 25.1 27.4 29.3 23.0 26.9 26.6 28.9 30.7 25.5 28.4 28.0 30.4 32.2
20.5 19.3 16.4 16.5 13.4 22.8 22.1 18.8 18.4 14.4 25.1 24.9 21.3 20.3 15.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
T.C.
S.C.
KW
19.0 23.2 23.0 25.8 28.3 21.7 25.0 24.6 27.4 29.7 24.4 26.7 26.1 28.9 31.2
19.0 18.6 15.6 15.9 12.9 21.4 21.2 18.1 18.0 14.1 23.9 23.7 20.5 20.0 15.3
85
1.7
1.7
1.7
1.7
1.8
1.7
1.7
1.7
1.8
1.8
1.7
1.7
1.7
1.8
1.8
T.C.
S.C.
KW
17.5 21.1 20.8 23.8 27.2 20.4 23.1 22.5 24.0 28.7 23.3 25.0 24.3 27.5 30.1
17.5 18.0 14.7 15.4 12.4 20.0 20.3 17.3 16.8 13.7 22.6 22.6 19.8 19.7 15.1
95
1.8
1.8
1.8
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
2.0
T.C.
S.C.
KW
16.2 19.0 18.4 21.7 24.8 18.7 21.0 20.2 23.3 26.3 21.3 22.9 22.0 24.9 27.7
16.1 16.6 13.7 14.4 11.6 18.4 18.6 15.9 16.6 13.0 20.6 20.6 18.2 18.8 14.5
105
115
125
2.0
2.0
2.0
2.0
2.1
2.0
2.0
2.0
2.0
2.1
2.0
2.0
2.0
2.1
2.1
T.C.
S.C.
KW
14.8 17.0 16.1 19.3 22.5 17.1 18.9 17.9 20.8 23.9 19.4 20.9 19.7 22.3 25.4
14.8 15.3 12.7 13.5 10.8 16.8 17.0 14.6 15.7 12.4 18.7 18.7 16.5 17.8 13.9
2.1
2.1
2.1
2.1
2.2
2.1
2.1
2.1
2.2
2.2
2.2
2.2
2.1
2.2
2.3
T.C.
S.C.
KW
13.5 14.9 13.8 16.8 20.1 15.5 16.9 15.6 18.3 21.6 17.5 18.9 17.4 19.8 23.1
13.5 13.9 11.7 12.5 10.1 15.1 15.4 13.3 14.7 11.7 16.8 16.8 14.9 16.9 13.3
2.2
2.2
2.2
2.3
2.4
2.3
2.3
2.2
2.3
2.4
2.3
2.3
2.3
2.3
2.4
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler
Coil
T.C.
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
S.C.
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.04
1.04
1.00
1.04
1.00
1.03
1.00
1.00
KW
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.91
0.91
1.00
0.91
1.00
0.91
1.00
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
–
FC/MC/PC32
FC/MC/PC35
FC/MC/PC37
FC/MC/PC43
HC30
PV8*A12
FC/MC/PC32A
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC36A
FC/MC/PC36A
FC/MC/PC36B
FC/MC/PC37A
FC/MC/PC37A
FC/MC/PC43B
HC30
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.03
1.02
1.02
1.03
1.02
1.02
1.03
1.02
1.02
1.03
1.02
1.02
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
–
PV9*A12
–
P(C,V)9*B12
PV8*A12
–
–
PV9*A12
–
HC36
P(C,V)9*B12
PV8*A12
–
HC42
–
UC36
PV9*A12
AHP30
AV36
MV12B
MA08B
MV12B
MA08B
MV12B
MA08B
F4FP36
–
P(C,V)9*B12
PV8*A12
–
FC/MC36B
FC/MC36B
FC/MC35B
FC/MC35B
FC/MC43B
FC/MC43B
–
PV9*A12
HC30
P(C,V)9*B12
HC36
12
Johnson Controls Unitary Products
364834-YTG-C-0708
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
YCJD30S41S1(H)
INDOOR COIL MODEL NO.
FC/MC/PC35
IDCFM
ID DB (°F) 80
ID WB (°F) 57
800
75
1000
75
1200
CONDENSING
ENTERING AIR
TEMPERATURE
80
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
75
62
80
67
80
72
62
62
T.C.
S.C.
KW
28.4 31.4 30.8 33.1 34.4 29.8 31.8 31.4 33.4 34.5 31.2 32.3 32.1 33.7 34.7
28.8 25.8 21.7 21.2 16.0 30.4 28.2 23.6 22.6 17.1 31.9 30.7 25.4 24.0 18.1
65
75
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
T.C.
S.C.
KW
26.4 28.8 28.2 30.9 32.6 27.9 29.7 28.9 31.4 32.8 29.5 30.5 29.6 31.8 32.9
26.9 24.7 20.5 20.3 15.4 28.5 27.1 22.6 22.0 16.4 30.2 29.5 24.6 23.7 17.5
1.8
1.8
1.8
1.9
1.9
1.8
1.8
1.8
1.9
1.9
1.9
1.9
1.9
1.9
1.9
T.C.
S.C.
KW
24.4 26.3 25.6 28.8 30.9 26.0 27.5 26.4 29.3 31.0 27.7 28.7 27.1 29.8 31.2
24.9 23.6 19.4 19.4 14.7 26.6 26.0 21.6 21.4 15.8 28.4 28.4 23.9 23.4 16.8
85
2.0
2.0
2.0
2.0
2.1
2.0
2.0
2.0
2.0
2.1
2.0
2.0
2.0
2.1
2.1
T.C.
S.C.
KW
22.4 23.8 23.0 26.7 29.1 24.2 25.3 23.8 29.0 29.3 26.0 26.9 24.7 27.9 29.4
22.9 22.5 18.2 18.5 14.1 24.8 24.9 20.7 21.2 15.1 26.7 27.3 23.1 23.1 16.2
95
2.1
2.1
2.1
2.2
2.3
2.2
2.2
2.2
2.2
2.3
2.2
2.2
2.2
2.2
2.3
T.C.
S.C.
KW
20.5 21.8 20.4 23.7 26.3 22.0 23.1 21.3 24.3 26.4 23.6 24.5 22.1 24.8 26.4
21.0 20.7 17.1 17.4 13.2 22.6 22.7 19.1 19.7 14.3 24.3 24.7 21.0 22.0 15.4
105
115
125
2.3
2.3
2.3
2.4
2.4
2.4
2.4
2.3
2.4
2.5
2.4
2.4
2.3
2.4
2.5
T.C.
S.C.
KW
18.6 19.8 17.9 20.9 23.5 19.9 21.0 18.8 21.4 23.5 21.2 22.2 19.6 21.8 23.6
19.1 18.9 15.9 16.4 12.3 20.5 20.5 17.5 18.6 13.5 22.0 22.2 19.1 20.9 14.7
2.5
2.5
2.4
2.5
2.6
2.5
2.5
2.5
2.5
2.6
2.6
2.6
2.5
2.6
2.6
T.C.
S.C.
KW
16.8 17.9 15.4 18.1 20.7 17.8 18.9 16.2 18.5 20.7 18.9 19.9 17.1 18.8 20.7
17.3 17.2 14.8 15.3 11.4 18.4 18.4 16.0 17.6 12.6 19.6 19.6 17.1 19.8 13.9
2.7
2.7
2.6
2.7
2.8
2.7
2.7
2.6
2.7
2.8
2.7
2.7
2.7
2.7
2.8
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler
–
Coil
T.C.
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.02
1.01
1.02
1.00
1.01
1.02
1.00
1.00
S.C.
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.03
1.02
1.02
1.00
1.02
1.02
1.00
1.00
KW
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.93
0.92
0.93
1.00
0.92
0.93
1.00
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
FC/MC/PC35
FC/MC/PC37
FC/MC/PC43
HC36
PV8*A12
FC/MC/PC32A
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC37A
FC/MC/PC37A
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
HC36
1.01
1.00
1.01
1.00
1.01
1.01
1.01
1.00
1.01
1.00
1.01
1.02
1.00
1.01
1.01
1.01
1.01
1.01
1.02
1.00
1.01
1.01
1.02
1.01
1.02
1.01
1.02
1.02
1.02
1.01
1.02
1.01
1.02
1.03
1.01
1.02
1.02
1.02
1.02
1.02
1.03
1.01
1.02
1.02
0.92
0.91
0.92
0.91
0.92
0.92
0.92
0.91
0.92
0.91
0.92
0.93
1.00
0.92
0.92
0.92
0.92
0.92
0.93
1.00
0.92
0.92
–
PV9*A12
–
PV8*B16
–
P(C,V)9*B12
PV8*C16
–
HC42
AHP30
AHP36
AV36
MV12B
MV16C
MA12B
MV12B
MV16C
MA12B
F4FP040
–
PV8*C20
–
P(C,V)9*C16
P(C,V)9*C20
PV8*A12
–
FC/MC35B
FC/MC35C
FC/MC35B
FC/MC43B
FC/MC43C
FC/MC43B
–
PV9*A12
PV8*B16
PV8*C16
PV8*C20
P(C,V)9*B12
P(C,V)9*C16
P(C,V)9*C20
PV8*B16
P(C,V)9*B12
PV8*C16
HC36
HC42
PV8*C20
HC42
P(C,V)9*C16
P(C,V)9*C20
HC42
HC42
Johnson Controls Unitary Products
13
364834-YTG-C-0708
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
YCJD36S41S1(H)
INDOOR COIL MODEL NO.
FC/MC/PC43
IDCFM
ID DB (°F) 80
ID WB (°F) 57
1000
75
1200
75
1400
75
CONDENSING
ENTERING AIR
TEMPERATURE
80
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
80
67
80
72
62
62
62
T.C.
S.C.
KW
34.7 36.1 35.2 37.4 37.3 33.8 35.5 34.8 37.0 37.5 32.9 34.9 34.4 36.6 37.6
34.3 33.0 27.6 25.5 18.4 33.3 31.0 26.2 24.6 18.0 32.3 29.1 24.7 23.6 17.7
65
75
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
1.9
2.0
1.9
2.0
2.0
T.C.
S.C.
KW
33.6 34.7 33.6 35.9 36.6 32.6 33.9 33.2 35.5 36.6 31.5 33.2 32.7 35.1 36.6
33.3 32.5 27.5 25.6 18.6 32.1 30.6 25.8 24.5 18.0 31.0 28.7 24.2 23.3 17.5
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.1
2.2
2.2
2.2
2.2
T.C.
S.C.
KW
32.4 33.2 32.0 34.4 35.8 31.3 32.3 31.5 34.1 35.7 30.2 31.5 31.0 33.7 35.5
32.2 32.0 27.3 25.8 18.8 30.9 30.2 25.5 24.3 18.0 29.6 28.3 23.7 22.9 17.3
85
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.3
2.4
2.4
2.4
2.4
T.C.
S.C.
KW
31.3 31.7 30.4 33.0 35.0 30.1 30.7 29.9 35.0 34.8 28.9 29.8 29.4 32.2 34.5
31.1 31.5 27.2 26.0 19.0 29.7 29.7 25.2 24.9 18.0 28.3 27.9 23.2 22.5 17.1
95
2.6
2.6
2.6
2.6
2.7
2.6
2.6
2.6
2.6
2.7
2.5
2.6
2.6
2.6
2.6
T.C.
S.C.
KW
27.9 28.8 27.2 29.8 32.5 27.0 27.8 26.6 29.4 32.2 26.0 26.9 25.9 29.0 31.9
28.7 28.9 25.0 25.0 18.4 27.3 27.2 23.2 23.2 17.3 25.8 25.6 21.5 21.4 16.2
105
115
125
2.8
2.8
2.8
2.8
2.9
2.8
2.8
2.8
2.8
2.9
2.7
2.8
2.7
2.8
2.9
T.C.
S.C.
KW
24.6 26.0 24.2 26.8 30.1 23.9 25.1 23.4 26.3 29.8 23.3 24.1 22.6 25.9 29.5
26.3 26.3 22.8 24.1 17.8 24.9 24.8 21.3 22.2 16.6 23.5 23.3 19.8 20.3 15.4
3.0
3.0
3.0
3.0
3.1
3.0
3.0
2.9
3.0
3.1
2.9
2.9
2.9
3.0
3.1
T.C.
S.C.
KW
21.3 23.2 21.1 23.7 27.6 20.9 22.3 20.2 23.2 27.3 20.5 21.3 19.3 22.7 27.0
23.9 23.8 20.6 23.2 17.2 22.5 22.4 19.4 21.2 15.9 21.1 21.0 18.2 19.2 14.6
3.2
3.2
3.2
3.2
3.4
3.2
3.2
3.1
3.2
3.3
3.1
3.1
3.1
3.2
3.3
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler
–
Coil
T.C.
1.00
1.00
1.00
1.00
1.00
1.00
1.01
1.01
1.00
1.01
1.01
1.00
1.01
1.00
S.C.
1.00
1.00
1.00
1.00
1.00
1.00
1.01
1.02
1.00
1.02
1.03
1.00
1.02
1.00
KW
1.00
1.00
1.00
1.00
1.00
1.00
0.92
0.92
1.00
0.92
0.92
1.00
0.92
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
FC/MC/PC43
FC/MC/PC48
HC42
PV8*A12
FC/MC/PC37A
FC/MC/PC37A
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48D
HC42
1.00
1.00
1.01
1.01
1.01
1.00
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.00
1.00
1.01
1.02
1.01
1.01
1.01
1.01
1.02
1.01
1.02
1.01
1.02
1.02
1.01
1.01
1.01
0.91
1.00
0.92
0.92
0.92
0.91
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
–
PV9*A12
–
PV8*B16
–
UC48
PV8*C16
AHP36
AHP42
AV36
–
PV8*C20
–
P(C,V)9*B12
P(C,V)9*C16
P(C,V)9*C20
PV8*C16
–
MV16C
MA12B
MV16C
MV20D
MA14D
MV12D
F5FP048
FC/MC43C
FC/MC43B
FC/MC48C
FC/MC48D
FC/MC48D
FC/MC48D
–
PV8*C20
P(C,V)9*C16
P(C,V)9*C20
P(C,V)9*D20
PV8*C16
PV8*C20
HC42
P(C,V)9*C16
P(C,V)9*C20
HC42
HC42
14
Johnson Controls Unitary Products
364834-YTG-C-0708
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
YCJD42S41S1(H)
INDOOR COIL MODEL NO.
FC/MC/PC43
IDCFM
ID DB (°F) 80
ID WB (°F) 57
1200
75
1400
75
1600
CONDENSING
ENTERING AIR
TEMPERATURE
80
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
75
62
80
67
80
72
62
62
T.C.
S.C.
KW
44.4 45.5 43.6 47.0 48.5 45.9 46.5 45.0 48.5 49.8 47.5 47.5 46.5 50.1 51.1
41.5 35.6 29.7 28.7 21.5 42.9 37.5 31.4 30.2 22.9 44.4 39.4 33.2 31.7 24.3
65
75
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.5
2.5
2.5
2.5
2.6
T.C.
S.C.
KW
42.3 42.9 41.2 45.1 46.6 44.2 44.3 42.7 46.6 47.9 46.0 45.7 44.2 48.1 49.1
39.4 35.2 29.2 28.5 21.3 41.1 37.4 31.1 30.1 22.4 42.9 39.7 33.0 31.8 23.6
2.7
2.7
2.7
2.8
2.8
2.7
2.7
2.7
2.8
2.8
2.8
2.8
2.8
2.8
2.9
T.C.
S.C.
KW
40.2 40.3 38.9 43.3 44.6 42.4 42.1 40.4 44.7 45.9 44.6 43.9 41.9 46.0 47.2
37.2 34.7 28.7 28.2 21.2 39.3 37.3 30.8 30.0 22.0 41.5 40.0 32.9 31.8 22.9
85
3.0
3.0
3.0
3.0
3.1
3.0
3.0
3.0
3.1
3.1
3.0
3.0
3.0
3.1
3.1
T.C.
S.C.
KW
38.2 37.7 36.5 41.5 42.7 40.7 39.9 38.0 42.0 44.0 43.2 42.1 39.6 43.9 45.3
35.0 34.3 28.1 28.0 21.0 37.5 37.3 30.5 29.4 21.6 40.0 40.3 32.8 31.9 22.2
95
3.2
3.2
3.2
3.3
3.4
3.3
3.3
3.3
3.3
3.4
3.3
3.3
3.3
3.4
3.4
T.C.
S.C.
KW
35.3 34.7 32.8 37.4 38.7 37.5 36.7 34.2 38.6 39.8 39.8 38.8 35.6 39.8 40.9
32.3 32.1 26.5 26.4 19.6 34.5 34.5 28.8 28.4 20.4 36.7 37.0 31.1 30.5 21.2
105
115
125
3.5
3.5
3.5
3.6
3.7
3.5
3.5
3.5
3.6
3.7
3.6
3.6
3.5
3.6
3.7
T.C.
S.C.
KW
32.4 31.7 29.2 33.4 34.8 34.5 33.6 30.5 34.6 35.7 36.5 35.5 31.8 35.7 36.7
29.7 30.0 25.0 24.9 18.2 31.6 31.9 27.2 27.0 19.3 33.5 33.8 29.4 29.1 20.3
3.7
3.7
3.7
3.8
4.0
3.8
3.8
3.7
3.8
4.0
3.8
3.8
3.7
3.9
4.0
T.C.
S.C.
KW
29.6 28.8 25.6 29.4 30.9 31.4 30.5 26.8 30.5 31.7 33.2 32.2 28.0 31.7 32.5
27.1 27.9 23.5 23.4 16.8 28.7 29.3 25.6 25.6 18.1 30.2 30.6 27.6 27.8 19.4
4.0
4.0
3.9
4.0
4.2
4.0
4.0
4.0
4.1
4.3
4.1
4.1
4.0
4.1
4.3
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler
–
Coil
T.C.
1.00
1.00
1.00
0.97
1.00
1.00
1.00
1.00
1.00
1.00
1.00
S.C.
1.00
1.00
1.00
1.00
1.02
1.00
1.02
1.02
1.00
1.00
1.00
KW
1.00
1.00
1.00
0.97
0.91
1.00
0.91
0.91
1.00
1.00
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
FC/MC/PC48
HC42
PV8*B16
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48D
HC42
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.01
1.02
1.01
1.02
1.01
1.02
1.01
1.02
1.02
1.01
1.02
1.01
1.02
0.91
0.91
1.00
0.91
0.91
0.91
1.00
0.91
0.91
0.91
0.91
1.00
0.91
–
PV8*C20
–
UC48
P(C,V)9*C16
P(C,V)9*C20
PV8*C16
AHP42
MV16C
MA16C
MV16C
MV20D
MA14D
MA16C
F5FP048
–
FC/MC43C
FC/MC43C
FC/MC48C
FC/MC48D
FC/MC48D
FC/MC48C
–
PV8*C20
P(C,V)9*C16
P(C,V)9*C20
P(C,V)9*D20
PV8*C16
PV8*C20
HC42
P(C,V)9*C16
P(C,V)9*C20
HC42
HC42
Johnson Controls Unitary Products
15
364834-YTG-C-0708
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
YCJD48S41S1(H)
INDOOR COIL MODEL NO.
FC/MC/PC48
IDCFM
ID DB (°F) 80
ID WB (°F) 57
1400
75
1600
75
1800
75
CONDENSING
ENTERING AIR
TEMPERATURE
80
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
80
67
80
72
62
62
62
T.C.
S.C.
KW
49.7 51.4 50.6 55.8 54.6 52.0 53.1 51.9 56.4 55.4 54.4 54.7 53.2 56.9 56.3
47.2 43.1 35.9 36.0 26.1 49.2 45.9 38.2 37.4 27.6 51.2 48.7 40.4 38.8 29.0
65
75
2.7
2.8
2.8
2.8
2.8
2.7
2.8
2.8
2.8
2.8
2.7
2.8
2.8
2.8
2.9
T.C.
S.C.
KW
47.5 48.6 47.7 52.9 52.4 49.8 50.3 48.9 53.6 53.1 52.0 52.1 50.2 54.3 53.8
44.9 42.0 35.0 34.9 25.4 47.0 44.8 37.1 36.5 26.8 49.0 47.6 39.3 38.2 28.1
3.0
3.0
3.0
3.1
3.1
3.0
3.0
3.0
3.1
3.2
3.0
3.0
3.0
3.1
3.2
T.C.
S.C.
KW
45.4 45.8 44.8 49.9 50.2 47.5 47.6 46.0 50.8 50.8 49.7 49.4 47.1 51.7 51.4
42.7 41.0 34.0 33.8 24.8 44.7 43.7 36.1 35.7 26.0 46.8 46.5 38.2 37.6 27.2
85
3.2
3.3
3.3
3.4
3.4
3.3
3.3
3.3
3.4
3.5
3.3
3.3
3.3
3.4
3.5
T.C.
S.C.
KW
43.2 42.9 42.0 47.0 47.9 45.3 44.9 43.1 48.0 48.4 47.4 46.8 44.1 49.1 48.9
40.4 39.9 33.0 32.7 24.1 42.4 42.6 35.1 34.6 25.2 44.5 45.4 37.1 37.0 26.3
95
3.5
3.5
3.5
3.6
3.7
3.6
3.6
3.5
3.7
3.8
3.6
3.6
3.6
3.7
3.8
T.C.
S.C.
KW
39.8 39.4 37.3 42.4 43.6 41.6 41.1 38.4 43.4 44.0 43.5 42.9 39.5 44.4 44.5
37.1 37.0 30.9 30.9 22.9 38.9 39.3 32.9 33.0 23.9 40.8 41.5 34.9 35.1 25.0
105
115
125
3.8
3.8
3.8
3.9
4.0
3.9
3.9
3.8
3.9
4.1
3.9
3.9
3.8
4.0
4.1
T.C.
S.C.
KW
36.5 35.9 32.7 38.0 39.3 38.1 37.5 33.9 38.9 39.8 39.7 39.1 35.1 39.8 40.2
33.9 34.2 28.9 29.2 21.6 35.5 36.0 30.9 31.3 22.7 37.2 37.7 32.8 33.3 23.8
4.1
4.1
4.0
4.2
4.3
4.1
4.1
4.1
4.2
4.4
4.2
4.2
4.1
4.2
4.4
T.C.
S.C.
KW
33.1 32.4 28.1 33.5 35.1 34.5 33.8 29.4 34.4 35.5 35.9 35.3 30.6 35.2 36.0
30.7 31.4 26.9 27.5 20.4 32.1 32.7 28.8 29.6 21.5 33.5 34.0 30.7 31.6 22.5
4.4
4.4
4.3
4.4
4.6
4.4
4.4
4.3
4.5
4.7
4.5
4.5
4.4
4.5
4.7
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler
–
Coil
T.C.
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
S.C.
1.00
1.00
1.00
1.00
1.00
1.01
1.01
1.01
1.01
1.01
1.00
1.00
1.01
1.00
1.00
1.00
1.00
1.01
KW
1.00
1.00
1.00
1.00
1.00
1.00
0.91
0.91
0.91
0.91
1.00
1.00
0.91
1.00
1.00
1.00
1.00
0.95
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
FC/MC/PC60
PV8*C16
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48D
FC/PC60C
0.97
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.01
1.00
1.00
1.00
1.00
1.01
0.97
1.00
1.00
1.00
0.91
1.00
1.00
1.00
1.00
0.91
–
HC60
PV8*C20
–
UC48
P(C,V)9*C16
P(C,V)9*C20
P(C,V)9*D20
PV8*C16
–
UC60
AHP/SHP48
AHP/SHP60
AV/SV48
AV/SV60
MV16C
MV20D
MA16C
MA20D
MV20D
MA16C
MA20D
F5FP048
F5FP060
F4FV060
–
–
–
PV8*C20
FC/PC60C
–
P(C,V)9*C16
P(C,V)9*C20
P(C,V)9*D20
FC/PC60C
FC/MC48C
FC/MC48D
FC/MC48C
FC/MC48D
FC/MC60D
FC60C
FC/MC60D
–
FC/PC60C
FC/MC/PC60D
–
–
16
Johnson Controls Unitary Products
364834-YTG-C-0708
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
YCJD60S41S1(H)
INDOOR COIL MODEL NO.
FC/MC/PC60
IDCFM
ID DB (°F) 80
ID WB (°F) 57
1400
75
1600
75
1800
CONDENSING
ENTERING AIR
TEMPERATURE
80
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
75
62
80
67
80
72
62
62
T.C.
S.C.
KW
55.8 63.8 62.1 65.2 71.9 60.3 65.7 62.8 66.7 69.8 64.8 67.5 63.5 68.2 67.8
54.7 51.6 41.4 41.1 34.1 58.4 54.2 43.9 42.6 31.9 62.1 56.8 46.5 44.2 29.6
65
75
3.0
3.0
3.0
3.1
3.1
3.0
3.0
3.0
3.1
3.1
3.0
3.1
3.0
3.1
3.1
T.C.
S.C.
KW
56.9 61.1 58.9 62.7 69.7 59.2 63.0 59.9 64.3 67.9 61.4 64.9 61.0 65.9 66.0
53.9 50.4 40.5 40.0 33.5 55.8 53.1 43.1 41.8 31.5 57.7 55.7 45.6 43.6 29.5
3.4
3.5
3.5
3.5
3.6
3.4
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
T.C.
S.C.
KW
58.0 58.4 55.7 60.3 67.6 58.0 60.4 57.1 61.9 65.9 58.1 62.4 58.5 63.6 64.1
53.2 49.3 39.7 39.0 32.9 53.3 52.0 42.2 41.0 31.2 53.4 54.7 44.8 42.9 29.4
85
3.9
3.9
3.9
3.9
4.0
3.9
3.9
3.9
3.9
4.0
3.9
3.9
3.9
3.9
4.0
T.C.
S.C.
KW
59.1 55.7 52.5 56.9 65.5 56.9 57.8 54.3 57.0 63.9 54.7 59.8 56.0 61.2 62.2
52.4 48.1 38.8 37.9 32.3 50.7 50.9 41.4 38.8 30.8 49.0 53.6 43.9 42.3 29.4
95
4.3
4.3
4.3
4.4
4.5
4.3
4.3
4.3
4.4
4.4
4.3
4.3
4.3
4.4
4.4
T.C.
S.C.
KW
56.4 52.2 48.8 54.0 60.1 54.0 54.3 50.5 55.7 59.7 51.6 56.3 52.2 57.4 59.4
49.7 45.9 37.5 36.5 29.7 47.9 48.3 40.0 38.7 29.4 46.2 50.6 42.5 40.9 29.0
105
115
125
4.9
4.9
4.9
4.9
5.0
4.9
4.9
4.9
5.0
5.0
4.9
4.9
4.9
5.0
5.0
T.C.
S.C.
KW
53.8 48.8 45.2 50.2 54.8 51.2 50.9 46.8 51.9 55.7 48.7 53.0 48.5 53.6 56.6
47.1 43.8 36.2 35.0 27.3 45.3 45.7 38.6 37.3 27.9 43.5 47.7 41.1 39.6 28.6
5.5
5.4
5.4
5.5
5.6
5.5
5.5
5.4
5.5
5.6
5.4
5.5
5.4
5.5
5.6
T.C.
S.C.
KW
51.2 45.4 41.6 46.5 49.4 48.5 47.5 43.2 48.2 51.6 45.7 49.7 44.8 49.8 53.8
44.5 41.7 34.9 33.6 24.9 42.6 43.2 37.3 35.9 26.5 40.7 44.7 39.7 38.3 28.2
6.1
6.0
5.9
6.1
6.2
6.0
6.0
6.0
6.1
6.2
6.0
6.0
6.0
6.1
6.2
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Air Handler
–
Coil
T.C.
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
S.C.
1.00
1.00
1.00
1.00
1.01
1.01
1.00
1.01
1.00
1.00
1.01
KW
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
FC/MC62
PV8*C20
FC/PC/UC60C
FC/PC/UC60C
FC/MC/PC/UC60D
FC/MC62D
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
–
HC60
P(C,V)9*C20
P(C,V)9*D20
PV8*C20
–
UC60
AHP/SHP60
AV/SV60
MV20D
MA20D
MV20D
MA20D
F5FP060
F4FV060
–
–
P(C,V)9*C20
P(C,V)9*D20
FC/MC62D
FC/MC60D
FC/MC60D
FC/MC62D
FC/MC62D
–
FC/MC62D
–
Johnson Controls Unitary Products
17
NOTES
Subject to change without notice. Printed in U.S.A.
Copyright © 2008 by Johnson Controls, Inc. All rights reserved.
364834-YTG-C-0708
Supersedes: 364834-YTG-B-0408
Johnson Controls Unitary Products