444555-YTG-A-0209
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and venr piping.
TECHNICAL GUIDE
96% TWO STAGE VARIABLE SPEED
GAS-FIRED RESIDENTIAL
FEATURES
MULTI-POSITION GAS FURNACES
•
Two stage heating operation includes two stage gas valve,
two stage inducer operation and variable speed ECM blower
operation. Adjustable delay timer allows two stage operation
with a single stage thermostat.
MODELS: TM9V
NATURAL GAS
60 - 120 MBH INPUT
•
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
•
•
Compact, easy to install, ideal height 33" tall cabinet.
ECM variable speed drive for cooling SEER enhancement,
improved comfort with optional airflow delay profiles, and
continuous fan options for IAQ performance.
•
•
•
•
•
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit amp requirement for easy replacement application.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
•
•
100% shut off main gas valve for extra safety.
24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
•
Hi-tech tubular aluminized steel primary heat exchanger with
stainless steel tube/aluminum fin secondary heat exchanger
for outstanding efficiency.
•
•
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow for
ductblaster conditions.
EFFICIENCY
RATING
CERTIFIED
•
•
•
•
•
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation, burner, and blower operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
ISO 9001
Certified Quality
Management System
•
•
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Due to continuous product improvement,
specifications are subject to change without notice.
Insulated blower compartment for thermal and acoustic
performance.
up-to-date technical information.
•
•
1/4 turn knobs provided for easy independent door removal.
Internal condensate trap design (patent pending) provides
condensate management options, easy visual operation
check, and is self priming to prevent nuisance problems.
Additional efficiency rating information can
•
•
Protection included from air intake, exhaust vent or
condensate blockage.
WARRANTY
Lifetime limited warranty on both heat exchangers to the origi-
nal purchaser; a 20-year limited warranty from original installa-
tion date to subsequent purchaser.
Venting applications maybe installed as either 2 pipe sealed
combustion or single pipe vent using indoor combustion air.
10-year warranty on the heat exchanger in commercial applica-
tions.
5-year limited parts warranty.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
444555-YTG-A-0209
SIDEWALL VENT TERMINATION KIT -
S1-1HT0901 (3")
S1-1HT0902 (2")
For use on sidewall, two-pipe installations only. Provide a more
attractive termination for locations where the terminal is visable
on the side of the home.
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Perfor-
mance” table listed above represents blower performance
WITHOUT filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabi-
net. DO NOT attempt to install any filters inside the furnace.
CONDENSATE NEUTRALIZER KIT - 1NK0301
Neutralizer cartridge has a 1/2" plastic tube fittings for installa-
tion in the drain line. Calcium carbonate refill media is also
available from the Source 1 Parts (p/n 026-30228-000).
NOTE: Single side return above 1800 CFM is approved as long
as the filter velocity does not exceed filter manufacturer’s rec-
ommendation and a transition is used to allow use on a 20x25
filter.
SIDE RETURN FILTER RACKS -
S1-1SR0200 - All Models
S1-1SR0402 - All Models
Recommended Filter Sizes (High velocity 600 FPM)
BOTTOM RETURN FILTER RACKS -
Cabinet
Size
Side
(in)
Bottom
(in)
S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets
S1-1BR0521 or 1BR0621 - For 21” cabinets
S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets
CFM
1200
1600
2000
2000
B
C
C
D
16 x 25
16 x 25
16 x 25
20 x 25
20 x 25
22 x 25
1BR05xx series are galvanized steel filter racks. 1BR06xx are
pre-painted steel filter racks to match the appearance of the fur-
nace cabinet.
(2) 16 x 25
(2) 16 x 25
NOTES:
COMBUSTIBLE FLOOR BASE KIT -
1. Air velocity through throwaway type filters may not exceed 300 feet
per minute (91.4 m/min). All velocities over this require the use of
high velocity filters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 fil-
ter. For CFM greater than 1800, you may use two side returns or one
side and the bottom or one return with a transition to allow use of a
20x25 filter.
For installation of these furnaces in downflow applications
directly onto combustible flooring material, These kits are
required to prevent potential overheating situations.tible floor
base kit provides access for combustible airflow.
S1-1CB0517 - For 17-1/2” cabinets
S1-1CB0521 - For 21” cabinets
Unit Clearances to Combustibles
S1-1CB0524 - For 24-1/2” cabinets
Application
Top
Upflow
Downflow
Horizontal
EAC TRANSITION KITS -
1"
0"
0"
0"
0"
0"
0"
For installation of EAC accessories with these furnaces to pro-
vide easy transition of return airflow through the EAC to get the
proper sealing and reduced airflow leakage.
Vent
0"
0"
Rear
0"
0"
Side
0"
1"
0"
S1-1TK1001 - For all models using side return
Front*
Floor
0"
Combustible
Yes
S1-1TK1017 - For 17-1/2” cabinets using bottom return
S1-1TK1021 - For 21” cabinets using bottom return
S1-1TK1024 - For 24-1/2” cabinets using bottom return
Combustible1
Combustible
Yes
Closet
Line Contact
Yes
No
No
Yes
HIGH ALTITUDE PRESSURE SWITCHES -
1. For combustible floors only when used with special sub-base.
* - 24" clearance in front and 18" on side recommended for service access.
All furnaces approved for alcove and attic installation.
For installation where the altitude is less than 5,000 feet it is not
required that the pressure switch be changed. For altitudes
above 5,000 feet, see kits below.
ACCESSORIES
PROPANE (LP) CONVERSION KIT -
S1-1PS3306 - 080
S1-1PS3307 - 060
S1-1NP0347 - All Models
This accessory conversion kit may be used to convert natural
gas (N) units for propane (LP) operation.
S1-1PS3302 - 100, 120
ROOM THERMOSTATS - A wide selection of compatible ther-
mosets are available to provide optimum performance and fea-
tures for any installation.
CONCENTRIC VENT TERMINATION -
S1-1CT0302 (2") & S1-1CT0302-636 (2")
S1-1CT0303 (3") & S1-1CT0303-636 (3")
1H/1C, manual change-over electronic non-programmable ther-
mostat.
For use through rooftop, sidewall. Allows combustion air to
enter and exhaust to exit through single common hole. Elimi-
nates unslightly elbows for a cleaner installation.
1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.
1H/1C, auto/manual changeover, electronic programmable.
* For the most current accessory information, refer to the price
book or consult factory.
Johnson Controls Unitary Products
3
AIR FLOW DATA
HIGH / LOW SPEED COOLING AND HEAT PUMP CFM
080B12
060B12
080C16
100C20
Jumper Settings
High
1343
1116
1235
1026
1079
889
900
787
814
712
Low
865
727
791
661
709
590
599
531
542
490
499
456
High
1320
1093
1203
1001
1080
880
910
803
836
738
Low
882
755
810
693
730
641
642
585
597
557
561
529
COOL Tap
ADJ Tap*
A
B
A
B
A
C
B
D
C
D
C
D
B
B
A
A
C
B
C
B
A
A
C
C
725
641
749
682
100C16
Jumper Settings
High
1787
1503
1620
1405
1462
1217
1245
940
Low
1171
987
1053
914
964
785
818
608
702
551
626
544
High
1818
1545
1661
1427
1497
1234
1265
977
1116
884
1019
791
Low
1192
1030
1083
936
991
819
832
648
728
572
666
519
COOL Tap
ADJ Tap*
A
B
A
B
A
C
B
D
C
D
C
D
B
B
A
A
C
B
C
B
A
A
C
C
1091
852
983
764
120D20
Jumper Settings
High
2019
1790
1818
1630
1649
1269
1432
1078
1169
986
Low
1290
1174
1195
1068
1082
848
956
704
770
638
High
2006
1687
1845
1552
1694
1502
1400
1365
1364
1232
1225
1117
Low
1397
1131
1282
1050
1157
1011
944
922
931
808
808
COOL Tap
ADJ Tap*
A
B
A
B
A
C
B
D
C
D
C
D
B
B
A
A
C
B
C
B
A
A
C
C
1062
866
685
576
718
HIGH / LOW HEAT CFM
80B12
060B12
80C16
Jumper Settings
High
1364
1253
1102
1014
Low
843
745
660
607
High
Low
945
887
840
768
HEAT Tap
ADJ Tap*
Any
1433
1320
1223
1134
A
B
C
D
Any
Any
Any
100C16
120D20
Jumper Settings
High
1684
1542
1426
1289
Low
1095
1011
927
High
1795
1585
1420
1201
Low
1171
1047
929
HEAT Tap
ADJ Tap*
Any
A
B
C
D
Any
Any
Any
832
785
100C20
Jumper Settings
High
2194
1999
1799
1614
Low
1417
1290
1182
1062
High
1937
1757
1594
1429
Low
1323
1199
1062
957
HEAT Tap
ADJ Tap*
Any
Any
Any
Any
A
B
C
D
All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w.c.
static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w.c. external static
pressure is not recommended.
NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower that what is required to operate an airflow switch on certain models of electronic air clean-
ers. Consult the instructions for the electronic air cleaner for further details.
* The ADJ “D” tap should not be used.
Subject to change without notice. Printed in U.S.A.
Copyright © 2008 by Johnson Controls, Inc. All rights reserved.
444555-YTG-A-0209
Supersedes: Nothing
Johnson Controls Unitary Products
5005 York Drive
Norman, OK 73069
|