Preparation before use
Before using the air conditioner, be sure to check and preset the following.
Remote Controller presetting
The remote controller is NOT presetting as Cooling Only Air Conditioner or Heat Pump by manufacturer.
Each time after the remote controller replaces batteries or is energized, the Cooling indicator
Heating indicator will flashes alternately on LCD of the remote controller.
and
User can preset the remote controller type depending on the air conditioner type you have purchased
as follows:
Press any button when
Press any button when
flashes, Heat Pump is set.
flashes, Cooling Only is set.
If you don't press any button within 12 seconds, the remote controller is preset as Heat Pump automatically.
Note:
If the air conditioner you purchased is a Cooling Only one, but you preset the remote controller as Heat Pump, it doesn't
bring any matter. But if the air conditioner you purchased is a Heat Pump one, and you preset the remote controller as
Cooling Only, then you CAN NOT preset the Heating operation with the remote controller.
Back-light function (optional)
Hold down any button of remote controller for about 2 seconds, back-light turns on. Release the button,
it lights off automatically 10 seconds later.
Note: Back-light is an optional function.
Auto Restart Presetting
If you want auto restart function,let the appliance is energized, hold down the Emergency
button (ON/OFF) on the indoor unit for over 5 seconds, auto restart function is set with buzz sound,
air conditioner is on standby.
If auto restart has been set, hold down the Emergency button (ON/OFF) on the indoor unit for over 5
seconds, auto restart function is canceled with buzz sound, air conditioner is on standby.
1
Safety precautions
Symbols in this Use and Care Manual are interpreted as shown below.
Be sure not to do.
Be sure to follow this instruction.
Grounding is essential.
The feature of the appliance,
instead of a fault.
Warning: Incorrect handling could
cause a serious hazard, such as death,
serious injury, etc.
Pay attention to such a situation.
ON
ON
Use correct power supply in
OFF
OFF
accordance with the rating plate
requirement. Otherwise, serious
faults or hazard may occur or a
Keep the power supply circuit breaker
or plug from dirt. Connect the power
supply cord to it firmly and correctly,
lest an electric shock or a fire break out
due to insufficient contact.
fire maybe break out.
Do not use the power supply circuit
breaker or pull off the plug to turn it off
during operation. This may cause a fire
due to spark, etc.
Do not knit, pull or press the power supply
cord, lest the power supply cord be broken.
An electric shock or fire is probably caused
by a broken power supply cord.
It is harmful to your health if the cool air
reaches you for a long time. It is advisable
to let the air flow be deflected to all the room.
Never insert a stick or similar obstacle
to the unit. Since the fan rotates at high
speed, this may cause an injury.
ON
OFF
FAN
MODE
Do not repair the appliance by yourself.
If this is done incorrectly, it may cause an
electric shock, etc.
Turn off the appliance by remote control
firstly before cutting off power supply if
malfunction occurs.
Prevent the air flow from reaching the gas
burners and stove.
It is the user's responsibility to make the
appliance be grounded according to
Do not touch the operation buttons
when your hands are wet.
Do not put any objects on the outdoor local codes or ordinances by a licenced
unit.
technician.
2
Identification of parts
Indoor unit
Air Intake
Front Panel
Emergency Panel
Display Panel
Air Outlet
Vertical Adjustment
Louver
Horizontal Adjustment
Louver
O
N
O
J
F
E
F
T
T
I
M
E
R
O
N
F
A
N
T
I
M
E
R
O
M
O
F
D
F
E
T
R
A
M
S
C
L
O
C
K
G
IN
W
S
P
E
LE
S
LO
C
K
Air Filter
Remote Controller
Air Intake
Outdoor unit
Pipes and Power
Connection Cord
Drain Hose
Note: Condensate water drains
at COOLING or DRY operation.
Air Outlet
The figures in this manual are based on the external view of a standard model.
Consequently, the shape may differ from that of the air conditioner you have selected.
3
Identification of parts
UH series operating and display
Timer Indicator
Run Indicator
It is on during operation.
It lights up during the
set time.
It flashes during
defrosting.
Sleep Indicator
Compressor indicator
Temperature display
Display actual room
temperarure.
It lights up when
unit is in sleep mode.
It lights up when
.
compressor is running.
Display set temperature.
The shape and position of the switches and indicators may vary from different models, but their function are similar.
4
Remote controller
Remote controller
The remote controller transmits signals to the system.
ON/OFF BUTTON
1
The appliance will be started when it is
energized or will be stopped when it is
in operation, if you press this button.
MODE BUTTON
Press this button to select the operation mode.
2
3
1
ON
4
3
FAN BUTTON
Used to select fan speed in sequence
auto, high, medium or low.
OFF
2
6
7
ROOM TEMPERATURE
SETTING BUTTONS
Used to adjust the room temperature and
5
4
th
sense
the timer, also real time.
FAN
MODE
th
13
12
BUTTON
Used to enter fuzzy logic operation directly,
regardless of the unit is on or off.
6
7
sense
5
SWING BUTTON
Used to stop or start vertical adjustment
louver swinging and set the desired up/down
airflow direction.
11
10
8
9
SLEEP BUTTON
Used to set or cancel Sleep Mode operation.
8
9
LOCK BUTTON
When you press this button, all the buttons
are locked and not available. Press again to
cancel it.
CLOCK BUTTON
Used to set the current time.
10
13
BUTTON
Used to start or stop the fast cooling.
(Fast cooling operates at high fan speed with
18 C set temp automatically )
11 12
TIMER ON/OFF BUTTON
Used to set or cancel the timer operation.
Indication symbols on LCD:
Signal transmit.
Auto fan speed
6th sense indicator
Sleep indicator
Lock indicator
Jet indicator
Cooling indicator
Dry indicator
High fan speed
ON
Display set timer
OFF
Display current time
Fan only indicator
Medium fan speed
Heating indicator
Display set temperature
Low fan speed
Note: Each mode and relevant function will be further specified in following pages.
5
Remote controller
Remote controller
How to Insert the Batteries
Remove the battery cover according to the arrow direction.
Insert new batteries making sure that the (+) and (-) of
battery are matched correctly.
Reattach the cover by sliding it back into position.
Note:
Use 2 LR03 AA(1.5volt) batteries. Do not use rechargeable batteries.
Replace batteries with new ones of the same type when the display
becomes dim.
If the replacement is done within 1 minute, the remote controller
will keep original presetting. However, if you want to change the
presetting from Heat Pump to Cool Only or Cool Only to Heat Pump,
you should reload batteries 3 minutes after removing the old ones.
(Please refer to page 1 for details.)
Storage and Tips for Using the Remote Controller
The remote controller may be stored mounted on a wall with a holder.
Note: The remote controller holder is an optional part.
ON
OF
F
ON
OF
F
F
A
N
M
O
D
E
FA
N
MO
DE
How to Use
To operate the room air conditioner, aim
the remote controller to the signal receptor.
The remote controller will operate the air
conditioner at a distance of up to 7m when
pointing at signal receptor of indoor unit.
Signal receptor
Choose Cooling Only Remote controller or Heat Pump
Please refer to page 1 " Preparation before use" for details.
6
Operation instructions
Operation modes
Selecting mode
Each time MODE button is pressed, the operation mode
is changed in sequence:
COOLING
DRY
FAN ONLY
HEATING
Heating mode is NOT available for cooling only air conditioner.
FAN mode
Each time the "FAN" button is pressed, the fan speed is
changed in sequence:
ON
OFF
High
Medium
Auto
Low
th
At "FAN ONLY" mode, only "High","Medium" and "Low" are available.
At "DRY" mode, Fan speed is set at "Low" automatically, "FAN" button
is ineffective in this case.
sense
FAN
MODE
2
1
Setting temperature
Press once to raise temperature setting by 1
Press once to lower temperature setting by 1
Range of available set temperature
*HEATING, COOLING
DRY
18 ~32
unable to set
unable to set
ONLY
FAN
*Note: Heating mode is NOT available for cooling only models.
Turning on
Press button, when the appliance receives the
signal, the RUN indicator of the indoor unit lights up.
SWING, 6th sense, TIMER ON, TIMER OFF, CLOCK, SLEEP and Jet operation modes will be
specified in the following pages.
Changing modes during operation, sometimes the unit does not response at once. Wait 3 minutes.
During heating operation, air flow is not discharged at the beginning. After 2 5 minutes, the air flow will be discharged
until temperature of indoor heat exchanger rises.
Wait 3 minutes before restarting the appliance.
7
Operation instructions
Airflow direction control
Airflow direction control
ON
Vertical airflow is automatically adjusted to a certain angle
in accordance with the operation mode after turning on the unit.
OFF
The direction of airflow can be
th
Operation mode Direction of airflow
also adjusted to your own
requirement by pressing the
"SWING" button of the
remote controller.
sense
FAN
MODE
5
horizontal
downward
COOLING, DRY
*HEATING,
FAN ONLY
*Heating mode is only available for heat pump models.
Vertical airflow control (with the remote controller)
Using remote controller to set various angles of flow or specific angle
as you like.
Swinging airflow
Pressing "SWING" button once, the vertical adjustment
louver will swing up and down automatically.
Desired direction airflow
Pressing the "SWING" button again when the louvers swing
to a suitable angle as desired.
Horizontal airflow control (with hands)
Turning the control rods of the
horizontal adjustment louvers to
change horizontal air flow as shown.
Note: The shape of the unit may look different
from that of the air conditioner you have selected.
control rods of horizontal
adjustment louvers
Do not turn the vertical adjustment louvers manually, otherwise malfunction may occur. If that happens, turn off the unit
first and cut off the power supply, then restore power supply again.
It is better not to let the vertical adjustment louver tilt downward for a long time at COOLING or DRY mode to prevent
condensed water from dripping.
8
Operation instructions
6th sense mode
th
Press the
button, the unit enters 6th sense mode(fuzzy logic operation) directly regardless of
sense
the unit is on or off. In this mode, temperature and fan speed are automatically set based on the
actual room temperature.
Operation mode and temperature are determined by indoor temperature
Heat pump models
Indoor temperature
Operation mode
Target temperature
HEATING
21 or below
22
ON
OFF
FAN ONLY
21 -23
23 -26
Room temperature
decrease 1.5 after
operate for 3 minutes
DRY
th
sense
COOLING
26
Over 26
FAN
MODE
Cooling only models
Target temperature
Indoor temperature
Operation mode
Room temperature
decrease 1.5 after
operate for 3 minutes
DRY
26 or below
Over 26
COOLING
26
th
Button is ineffective in Jet mode.
sense
Note: Temperature, airflow and direction are controlled automatically in 6th mode.
can be set with the remote controller if you still
However, a decrease or rise of up to 2
feel uncomfortable.
What you can do in 6th sense mode
Your feeling
button
adjustment procedure
Uncomfortable
because of
unsuitable air
flow volume.
Indoor fan speed alternates among
High, Medium and Low each time this
button is pressed.
FAN
Press it once, the vertical adjustment
louver swings to change vertical airflow
direction. Press it again, swings stops.
For horizontal airflow direction, please
refer to the previous page for details.
Uncomfortable
because of
unsuitable flow
direction.
CLOCK button
You can adjust the real time by pressing CLOCK button, then
using and buttons to get the correct time, press
CLOCK button again the real time is set.
9
Operation instructions
Timer mode
It is convenient to set the timer on with TIMER ON/OFF buttons when you go out in the
morning to achieve a comfortable room temperature at the time you get home. You can
also set timer off at night to enjoy a good sleep.
How to set TIMER ON
TIMER ON button can be used to set the timer programming as wished in order to
switch on the appliance at your desired time.
i)
Press TIMER ON button, "ON 12:00" flashes on the LCD, then you
can press the
appliance on.
or
buttons to select your desired time for
Increase
Decrease
ON
Press the
Press the
or
or
button once to increase or decrease the time setting by 1 minute.
button one and a half seconds to increase or decrease the time
setting by 10 minute.
or
Press the
button for a longer time to increase or decrease the time by 1 hour.
Note: If you don't set the time in 10 seconds after you press TIMER ON button, the remote controller
will exit the TIMER ON mode automatically.
When your desired time displayed on LCD, press the TIMER ON button and confirm it.
ii)
A "beep" can be heard.
"ON" stops flashing.
The TIMER indicator on the indoor unit lights up.
iiI)
After the set timer displayed for 5 seconds the clock will be displayed on the LCD
of the remote controller instead of set timer.
How to cancle TIMER ON
Press the TIMER ON button again, a "beep" can be heard and the indicator disappears,
the TIMER ON mode has been canceled.
Note: It is similar to set TIMER OFF, you can make the appliance switch off automatically at your
desired time.
10
Operation instructions
SLEEP mode
SLEEP mode
SLEEP mode can be set in COOLING or HEATING operation mode.
This function gives you a more comfortable environment for sleep.
ON
In SLEEP mode,
The appliance will stop operation automatically after operating for 8 hours.
Fan speed is automatically set at low speed.
th
sense
*Set temperature will rise by 1 at most if the appliance operates in cooling
mode for 2 hours constantly, then keeps steady.
FAN
MODE
Set temperature will decrease by 3 at most if the appliance operates in
heating mode for 3 hours constantly, then keeps steady.
*Note: In cooling mode, if room temperature is 26 or above, set temperature
will not change.
Note: Heating is NOT available for cooling only air conditioner.
Jet mode
Jet mode
Jet mode is used to start or stop fast cooling.
Fast cooling operates at high fan speed, changing the set temperature
automatically to 18 .
Jet mode can be set when the appliance is in operation or energized.
In Jet mode, you can set airflow direction or timer. If you want to
escape from Jet mode, press any - , MODE, FAN, ON/OFF
or TEMPERATURE SETTING button, the display will return to the original
th
sense
FAN
MODE
1
mode.
Note:
SLEEP and th buttons are not available in Jet mode.
sense
Button is ineffective in HEATING mode.
The Appliance will continue working in Jet mode with set temperature of 18 , if
.you don't escape from it by pressing any of the buttons mentioned above.
1
11
Maintenance
Front panel maintenance
Air filter maintenance
Cut off the power supply
It is necessary to clean the air filter
after using it for about 100 hours.
Turn off the appliance
first before disconnecting
from power supply.
Clean it as follows:
a
Stop the appliance and remove
the air filter.
Grasp position "a" and
pull outward to remove the
front panel.
a
Wipe with a soft
and dry cloth.
1.Open the front panel.
2.Press the handle of the filter gently
from the front.
3. Grasp the handle and slide out the filter.
Use a dry and
Use lukewarm water
(below 40 ) to clean
if the appliance
soft cloth to
clean it.
is very dirty.
Never use volatile substance
such as gasoline or polishing
powder to clean the appliance.
Clean and reinstall the air filter.
If the dirt is conspicuous,
wash it with a solution of
detergent in lukewarm water.
After cleaning, dry well in
shade.
Never sprinkle water onto the
indoor unit
Dangerous!
Electric
shock!
Close the front panel again.
Reinstall and shut the front panel.
Clean the air filter every two weeks
if the air conditioner operates in an
extremely dusty environment.
Reinstall and shut the front panel by
pressing position "b" downward.
b
b
12
Protection
Noise pollution
Operating condition
The protective device maybe trip and stop
the appliance in the cases listed below.
Install the air conditioner at a place that
can bear its weight in order to operate
more quietly.
Outdoor air temperature is over *43oC
COOLING
Room temperature is below 21oC
Install the outdoor unit at a place where
the air discharged and the operation noise
would not annoy your neighbors.
Room temperature is below 18oC
DRY
Do not place any obstacles in front of the
air outlet of the outdoor unit lest it increases
the noise level.
If the air conditioner runs in COOLING or DRY mode with
door or window opened for a long time when relative
humidity is above 80%,dew may drip down from the outlet.
Features of protector
The protective device will work at following cases.
Restarting the unit at once after operation stops or changing mode during operation, you need to
wait 3 minutes.
Connect to power supply and turn on the unit at once, it may start 20 seconds later.
If all operation has stopped, press ON/OFFbutton again to restart, Timer should be set again
if it has been canceled.
13
Troubleshooting
The following cases may not always be a malfunction, please check it before asking for service.
Trouble
Analysis
If the protector trip or fuse is blown.
Please wait for 3 minutes and start again,
protector device may be preventing unit to work.
Does not run
.
If batteries in the remote controller exhausted.
If the plug is not properly plugged.
Is the air filter dirty?
No cooling or
heating air
Are the intakes and outlets of the air
conditioner blocked
Is the temperature set properly
If strong interference(from excessive static
electricity discharge, power supply voltage
abnormality)presents, operation will be
Ineffective control
abnormal. At this time, disconnect from the
power supply and connect back 2-3 seconds later.
Does not operate
immediately
Changing mode during operation, 3 minutes
will delay.
don't run
This odor may come from another source
such as furniture, cigarette etc, which is
sucked in the unit and blows out with the air.
Peculiar odor
Caused by the flow of refrigerant in the
air conditioner, not a trouble.
Defrosting sound in heating mode.
A sound of
flowing water
The sound may be generated by the expansion
or contraction of the front panel due to change
of temperature.
Cracking sound is
heard
Mist appears when the room air becomes
very cold because of cool air discharged
from indoor unit during COOLING or DRY
operation mode.
Spray mist from
the outlet
The unit is shifting from heating mode to defrost.
The indicator will lights off within ten minutes and
returns to heating mode.
The compressor indicator(red) lights on constantly,
and indoor fan stops.
14
Installation instructions
Installation diagram
Distance from ceiling
should be over 50 mm
Distance from wall
should be over 50mm
Distance from the wall
should be over 50mm
Distance from floor
should be over 2000mm
Air intake distance from the wall
should be over 250mm
Air intake distance from
the wall should be
over 250mm
over 250mm
Above figure is only a simple presentation
of the unit, it may not match the external
appearance of the unit you purchased.
Installation must be performed in accordance with
the national wiring standards by authorized personnel only.
15
Installation instructions
Select the best loca
tion
Location for Installing Indoor Unit
Where there is no obstacle near the air outlet and air can be
easily blown to every corner.
Indoor unit
Where piping and wall hole can be easily arranged.
Keep the required space from the unit to the ceiling and wall
according to the installation diagram on previous page.
Where the air filter can be easily removed.
Keep the unit and remote controller 1m or more apart from
television, radio etc.
Pipe length is
15 meters Max.
To prevent the effects of a fluorescent lamps, keep as far as
possible.
Outdoor unit
Do not put anything near the air inlet to obstruct it from air
absorption.
Where there is strong enough to bear the weight
and is not tend to increase operation noise and vibration.
Location for Installing Outdoor Unit
Outdoor unit
Where it is convenient to install and well ventilated.
Avoid installing it where flammable gas could leak.
Keep the required distance apart from the wall.
Pipe length is
15 meters Max.
The distance between Indoor and outdoor unit should
be 5 meters and can go up to maximum 15 meters
with additional refrigerant charge.
Keep the outdoor unit away from a place of greasy dirt,
vulcanization gas exit.
Avoid installing it at the roadside where there is a risk of
muddy water.
A fixed base where is not subject to increasing operation
noise.
Where there is not any blockage for air outlet.
Indoor unit
Max. Allowable Tubing
Length at Shipment (m)
Limit of Tubing
Length (m)
Limit of Elevation Required amount of
Difference H (m) additional refrigerant (g/m)
Model
9K~18K
5
15
5
20
16
Installation instructions
Indoor unit installation
1. Installing the Mounting Plate
Decide an installing location for the mounting plate according to the indoor unit location and piping direction.
Keep the mounting. plate horizontally with a horizontal ruler or dropping line.
Drill holes of 32mm in depth on the wall for fixing the plate.
Insert the plastic plugs to the hole, fix the mounting plate with tapping screws.
Inspect if the mounting plate is well fixed. Then drill a hole for piping.
Line drops from here
Hook the line here
Mounting plate
Dropping line
holes for fixing
Note: The shape of your mounting plate may be different from the one above, but installation method is similar.
2. Drill a Hole for Piping
r
o
Wall hole sleeve
( hard polythene tube
prepared by user)
o
Decide the position of hole for piping according to the
location of mounting plate.
d
t
u
O
Drill a hole on the wall. The hole should tilt a little
downward toward outside.
5mm
(tilt downward)
Install a sleeve through the wall hole to keep the wall
tidy and clean.
3. Indoor Unit Piping Installation
Put the piping (liquid and gas pipe) and cables through the wall hole from outside or put them through
from inside after indoor piping and cables connection complete so as to connect to outdoor unit.
Decide whether saw the unloading piece off in accordance with the piping direction.(as shown below)
Piping direction
trough
Unloading
piece
4
1
3
Note: When installing the pipe at the directions
1,2 or 4, saw the corresponding unloading piece
off the indoor unit base.
Saw the unloading piece
off along the trough
2
After connecting piping as required, install the drain hose. Then connect the power cords.After connecting,
wrap the piping, cords and drain hose together with thermal insulation materials.
17
Installation instructions
Piping Joints Thermal Insulation:
Wrap the piping joints with thermal
insulation materials and then wrap
with a vinyl tape.
wrapped with vinyl type
Thermal insulation
Piping Thermal Insulation:
Large pipe
Power cord
Thermal insulation
tube
a. Place the drain hose under the piping.
b. Insulation material uses polythene foam over 6mm in thickness.
Note: Drain hose is prepared by user.
Small
pipe
Drain pipe should point downward for easy drain flow.
Do not arrange the drain pipe twisted, sticking out or wave
around, do not immerse the end of it in water.
Power cord 1
(for heat-pump)
If an extension drain hose is connected to the drain pipe, make
sure to thermal insulated when passing along the indoor unit.
Drain hose
(prepared by user)
Defrost cable(for heat-pump)
When the piping is directed to the right, piping, power
Cord and drain pipe should be thermal insulated and
fixed onto the back of the unit with a piping fixer.
Insert here
large
pipe
large
pipe
drain
hose
drain
small
hose
pipe
small
pipe
Hook here
Base
Piping fixer
Base
Piping fixer
Base
A. Insert the pipe fixer to the slot.
B. Press to hook the pipe fixer onto the base.
Piping Connection:
a. Connect indoor unit pipes with two wrenches. Pay special attention
to the allowed torque as shown below to prevent the pipes, connectors
and flare nuts from being deformed and damaged.
b. Pre-tighten them with fingers at first, then use the wrenches.
Min.thickness
Pipe size
Liquid Side (1/4 inch)
Liquid Side (3/8 inch)
Gas Side (3/8 inch)
Gas Side (1/2 inch)
Gas Side (5/8 inch)
Nut width
Model
9,12K
Torque
1.8kg.m
3.5kg.m
3.5kg.m
5.5kg.m
7.5kg.m
17mm
0.6mm
0.6mm
0.6mm
0.6mm
0.6mm
18K
9K
22mm
22mm
24mm
27mm
12K
18K
18
Installation instructions
4. Connecting of the Cable
Front panel
Terminal (inside)
Indoor Unit
Connect the power connecting cord to the indoor unit
by connecting the wires to the terminals on the control
board individually in accordance with the outdoor unit
connection.
Cabinet
Chassis
Indoor unit
Note: For some models, it is necessary to remove the cabinet to
connect to indoor unit terminal.
Outdoor Unit
1). Remove the access door from the unit by loosening
the screw. Connect the wires to the terminals on the
control board individually as the following.
2). Secure the power connecting cord onto the control
board with cable clamp.
Access door
Terminal(inside)
3). Reinstall the access door to the original position
with the screw.
Outdoor unit
The figures in this manual are based on the external
view of a standard model. Consequently, the shape
may differ from that of the air conditioner you have
selected.
Caution:
1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of
wiring, refer to the circuit diagram posted on the inside of the access door .
2.Comfirm that the cable thickness is as specified in the power source specification.
(See the cable specification table below)
3.Check the wires and make sure that they are all tightly fastened after cable connection.
4. Be sure to install an earth leakage circuit breaker in wet or moist area.
Cable Specifications
Power cord
Power connecting cord
Main
power
supply
Capacity
(Btu/h)
Normal cross
Normal cross
Type
Type
- sectional area
1.0~1.5mm2X3
1.5~2.0mm2X3
- sectional area
1.5mm2X3
1.5mm2X3
H07RN-F
9K,12K
18K
To indoor
To indoor
H05VV-F
H05VV-F
RVV
H07RN-F
Attention:
Accessibility to the plug must be guaranteed even after the installation of the appliance to disconnect
it in case of need. If not possible, connect appliance to a double-pole switching device with contact
separation of at least 3 mm placed in an accessible position even after installation.
19
Installation instructions
Wiring Diagram
Make sure that the color of wires of the outdoor unit and the terminal No. are the same as those
of the indoor unit.
9K,12K,18K Model
COOLING ONLY
Indoor unit
Outdoor unit
Terminal
Terminal
Brown
Brown
1L
N
1L
N
Blue
Blue
Power connecting cord
Yellow/Green
Yellow/Green
For above models, the power supply are connected from indoor unit.
20
Installation instructions
Outdoor unit installation
1.Install Drain Port and Drain Hose (for heat-pump model only)
The condensate drains from the outdoor unit when the unit operates
in heating mode. In order not to disturb your neighbor and protect
the environment, install a drain port and a drain hose to direct the
condensate water. Just install the drain port and rubber washer to
the chassis of the outdoor unit, then connect a drain hose to the
port as the right figure shown.
Washer
Drain port
Drain hose
(prepare by user)
2. Install and Fix Outdoor Unit
Fix with bolts and nuts tightly on a flat and strong floor.
If installed on the wall or roof, make sure to fix the supporter well to prevent it
from shaking due to serious vibration or strong wind.
3. Outdoor Unit Piping Connection
Remove the valve caps from the 2-way and 3-way valve.
Connect the pipes to the 2-way and 3-way valves separately according to the required torque.
4. Outdoor Unit Cable Connection (see previous page)
Air purging
The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the
compressor. After connecting the indoor and outdoor units, evacuate air and moisture from refrigerant
cycle using a vacuum pump, as shown below.
Note: To protect the environment, be sure not to discharge the refrigerant to the air directly.
See next page for air purging steps.
Vacuum pump
indoor unit
Refrigerant flow direction
2-way valve
3-way valve diagram
3-way valve
connect to indoor unit
(6) Open 1/4 turn
(7) Turn to fully open the valve
valve cap
open position
spindle
(7) Turn to fully open the
valve
Service
port
(1) Turn
(8) Tighten
(1) Turn
(8) Tighten
(2) Turn
(8) Tighten
needle
Valve cap
Connect to outdoor unit
Valve core
service port cap
21
Installation instructions
How to Purge Air Tubes:
(1). Unscrew and remove caps from 2 and 3-way valves.
(2). Unscrew and remove cap from service valve.
(3). Connect vacuum pump flexible hose to the service valve.
(4). Start vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm Hg absolutes.
(5). With vacuum pump still running close the low pressure knob on vacuum pump manifold. Then stop
vacuum pump.
(6). Open 2-way valve 1/4 turn then close it after 10 seconds. Check tightness of all joints using liquid
soap or an electronic leak detector.
(7). Turn 2 and 3-way valves stem to fully the valves. Disconnect vacuum pump flexible hose.
(8). Replace and tighten all valve caps.
Notes
Please read this manual before installing and using it.
Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner.
Testing run the air conditioner after finishing installation, and record details of operation.
Type of fuse used on indoor unit controller is 50T, with rating 2.5A,AC250V.
The fuse for the whole unit is to be provided by the user according to the current at maximum power
Input or use other over-current protective device instead.
Only the air conditioner can be connected to the power line.
The power connection for the air conditioner has to be done at the main power distribution which has
to be of a low impedance.
In order to ensure the suitability of the equipment for connection, the user should consult with the
supply authority, if necessary, that the service current capacity at the interface point is sufficient
for the equipment.
Refer to the rating plate of the equipment for power consumption details.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or
similarly qualified person in order to avoid a hazard.
22
|