Vista 20se User Manual

Features Q.E.D. programming for quick  
enrollment of devices.  
Previous Menu  
VISTA-20SE  
2-PARTITIONED  
SECURITY SYSTEM  
PROGRAMMING  
FORM  
®
Principal changes between the VISTA-20SE and  
the former VISTA-20 are indicated by margin lines.  
VISTA-20PRV4 8/97 (See Instructions N7526V4)  
*
36  
ENTRY DELAY 2 (zone type 02)  
|
[6|0] [60]  
Part. 1  
Part. 2  
00-99 = entry delay 2 time for each  
partition; 50 seconds max. for UL installations  
*
*
37  
38  
AUDIBLE EXIT WARNING  
[1] [1]  
Part. 1  
Part. 1  
Part. 2  
0 = no; 1 = yes  
CONFIRMATION OF ARMING DING  
[0] [0]  
Part. 2  
0 = no; 1 = yes (wired keypads and RF); 2 = yes, RF only  
† [1]  
*
39  
POWER UP IN PREVIOUS STATE  
0 = no; 1 = yes; “1” for UL installations  
DIALER PROGRAMMING (*40–*53)  
*
*
*
In fields 40, 41, 42, enter up to the number of digits shown. Do not fill unused spaces. Enter 0–9; #+11 for '*';  
#+12 for '#'; #+13 for a pause.  
*
40  
PABX ACCESS CODE  
|
|
|
|
|
Enter 6 digits. If fewer than 6 digits are entered, exit by  
*
pressing (and press 41, if entering next field). To clear entries  
*
*
from field, press 40 .  
*
41  
PRIMARY PHONE No.  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Enter up to 16 digits; Do not fill unused spaces. If fewer than 16  
*
digits entered, exit by pressing (and press 42, if entering next  
*
*
field). To clear entries from field, press 41 .  
*
42  
SECONDARY PHONE No.  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Enter up to 16 digits; Do not fill unused spaces. If fewer than 16  
*
digits entered, exit by pressing (and press 43, if entering next  
*
*
field). To clear entries from field, press 42 .  
For fields *43 - *46:  
Enter 0–9; #+11 for B; #+12 for C; #+13  
for D; #+14 for E; [#+15 for F]. Enter as  
4th digit, if 3+1 dialer reporting is to be  
used. If only 3 digits used, exit by pressing  
*
*
43  
44  
PRIMARY SUBS ACCT # (Part. 1)  
|
|
|
|
|
|
|
|
|
*
SECONDARY SUBS ACCT # (Part. 1)  
*
*
45  
46  
PRIMARY SUBS ACCT # (Part. 2)  
*
(and press next field).  
To clear entries from field, press 43  
* *  
*
*
SECONDARY SUBS ACCT # (Part. 2)  
|
|
|
*
*
*
*
, 44 , 45 , or 46 .Examples:  
For Acct. 1234, enter:  
1 | 2 | 3 | 4  
NOTE: If using the paging feature, do not enter a  
leading 0 in the subscriber account number, and do  
not use digits A-F anywhere in the number. Some  
paging systems provide voice mail capability, which  
is activated by a leading 0 in the message.  
For Acct. B234, enter: #+11| 2 | 3 | 4  
For Acct. 123, enter:  
1 | 2 | 3 | *  
*
*
47  
48  
PHONE SYSTEM SELECT  
[1]  
If Cent. Sta. IS NOT on a WATS line: 0 = Pulse Dial; 1 = Tone  
Dial; if Cent. Sta. IS on a WATS line: 2 = Pulse Dial ; 3 = Tone  
Dial.  
REPORT FORMAT  
[7] [0]  
Primary Secondary  
0 = 3+1, 4+1 ADEMCO L/S STANDARD  
1 = 3+1, 4+1 RADIONICS STANDARD  
2 = 4+2 ADEMCO L/S STANDARD  
6 or undefined = 4+2 ADEMCO EXPRESS  
7 = ADEMCO CONTACT ID REPORTING  
8 = 3+1, 4+1 ADEMCO L/S EXPANDED  
9 = 3+1, 4+1 RADIONICS EXPANDED  
3 = 4+2 RADIONICS STANDARD  
Entry of a number other than one specified will give unpredictable results.  
– 3 –  
*
49  
SPLIT/DUAL REPORTING  
[0]  
0 = Disable (Backup report only)  
TO PRIMARY PHONE No.  
1 = Alarms, Restore, Cancel  
2 = All except Open/Close, Test  
3 = Alarms, Restore, Cancel  
4 = All except Open/Close, Test  
5 = All  
TO PRIMARY PHONE No.  
6 = All except Open/Close  
7 = All reports  
TO SECONDARY PHONE No.  
Others  
Open/Close, Test  
All  
All  
All  
TO PAGING No. * (Secondary)  
** Alarms, Open/Close, Troubles  
** Alarms, Troubles  
* * Alarms, Open/Close, Troubles  
* * Alarms , Open/Clos e for  
us ers 5-25 (us ers 5-16 or  
wireles s button z ones 10-  
25), Troubles  
** A 10-digit code is sent to the pager consisting  
of a 4-digit subscriber number, a 3-digit event code,  
and a 3-digit user or zone number.  
See Installation Instructions for an explanation  
of the 10-digit code.  
8 = All reports  
9 = All except Open/Close  
* Can only be us ed if primary reporting format is Ademc o Contac t ID.  
*
50  
15 SEC DIALER DELAY (BURG)  
[0]  
0 = no; 1 = yes; “0” for UL installations  
*
51  
PERIODIC TEST REPORT  
[0]  
0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days (Enter Test  
*
Code in field 64. Reports with Partition 1 subscriber No.)  
† [2]  
*
*
52  
53  
TEST REPORT OFFSET  
0 = 24 hour; 1 = 6 hours; 2 = 12 hours; 3 = 18 hours (Time to 1st  
report from programming or downloading).  
SESCOA/RADIONICS SELECT  
[0]  
0 = Radionics (0–9, B–F reporting); 1 = SESCOA (0–9 only  
reporting). Select 0 for all other formats.  
Entry of a number other than one specified will give unpredictable results.  
*
56 ZONE ASSIGNMENT/ALARM REPORT CODES —This field is an interactive mode. Fill in the required  
data on the worksheet below (and on next page) and follow the programming procedure in the installation  
manual.  
See explanation of headings on next page  
·
ZONES ON CONTROL:  
ZONE  
ZONE  
ZONE  
PART'N ALARM RPT CODE INPUT  
RESPONSE  
DESCRIPTION  
No.  
(Zn)  
TYPE  
(ZT)  
No.  
(P)  
(Hex)  
(RC)  
TYPE  
(In)  
TIME  
(RT)  
Wired Zone 1*  
Wired Zone 2  
Wired Zone 3  
Wired Zone 4  
Wired Zone 5  
Wired Zone 6  
Wired Zone 7  
Wired Zone 8**  
0
0
0
0
0
0
0
0
0
1
2
3
4
5
6
7
8
9
HW  
HW  
HW  
HW  
HW  
HW  
HW  
HW  
Ñ
Both  
Expansion Module  
Supervision  
0
5
Ñ
Both  
Both  
Both  
Both  
Duress  
Console Panic (1 & *, or A)  
9
9
9
9
2
5
6
9
Ñ
Ñ
Ñ
Ñ
Ñ
Ñ
Ñ
Ñ
Console Panic (3 & #, or C)  
Console Panic (* & #, or B)  
*Zone 1 can be used as a 2-wire Fire zone.  
**Zone 8 can be used as a Glassbreak zone.  
– 4 –  
EXPANSION ZONES: Assign zone numbers (Zn) 10–17 to 4219/4229 Auxiliary Wired Loops A–H, if used.  
ENTER FOR  
RF ONLY  
RF zones can use zone numbers (Zn) 10–31  
[
PART'N ALARM RPT CODE INPUT LEARNED  
[
ZONE  
DESCRIPTION  
ZONE  
No.  
(Zn)  
ZONE  
TYPE  
(ZT)  
No.  
(P)  
(Hex)  
(RC)  
TYPE RF INPUT  
(In) (L)  
4219/4229 Loop A 1st Exp'n Zone  
1
1
1
1
1
1
1
1
0
1
2
3
4
5
6
7
or RF Zones  
B
C
D
E
F
G
H
RF Zones  
1
1
2
2
2
2
2
2
8
9
0
1
2
3
4
5
RF Zones  
2
2
2
2
3
3
3
3
6
7
8
9
0
1
2
3
EXPLANATION OF ZONE ASSIGNMENT TABLE HEADINGS  
Zn = ZONE No. Zone Nos. are from 01 to 31, 92, 95, 96, 99. Some are pre-assigned.  
*
With Field 25 set for auxiliary wired loops (4219, or 4229), use Zone Nos. 10–17 for loops A–H.  
*
With Field 22 set for RF (5800), use Zone Nos. 10-31.  
ZT = ZONE TYPE 00 = Not Used  
05 = Trouble Day/Alarm Night  
06 = 24 Hr Silent  
07 = 24 Hr Audible  
08 = 24 Hr Aux  
20 = Arm–Stay  
DEFAULT VALUES  
01 = Entry/Exit #1  
02 = Entry/Exit #2  
03 = Perimeter  
21 = Arm–Away  
Zn: 01 02 03 04  
ZT: [09] [01] [03] (03)  
Zn: 05 06 07 08 99  
ZT: [03] [03] [03] [03] [06]  
22 = Disarm  
23 = No Alarm Response  
24 = Silent Burglary  
04 = Interior Follower  
09 = Fire  
10 = Interior w/Delay  
P = PARTITION No.  
RC = ALARM REPORT CODE Two Hex Digits.  
1 or 2  
Default Values for zones 01 – 08 = [1].  
For each Hex Digit, enter: 00–09 for 0–9, 10 for A, 11 for B,12 for C, 13 for  
D, 14 for E, 15 for F. If "00" is entered as the first digit, there will be no report for that zone.  
For contact ID reporting, this is enabling code only. Enter any hex digit (other than 00) in  
the first pair of boxes. The second pair of boxes is ignored.  
In = LOOP INPUT TYPE HW: Hard Wire  
AW: Aux Wire (4219 or 4229)  
Enter 2 for AW: Auxiliary wired  
Hard wire zone input  
types are automatically  
assigned.  
Enter 3 for RF: Supervised RF  
Enter 4 for UR: Unsupervised RF  
Enter 5 for BR: Button Type RF  
RT = RESPONSE TIME 0 = 10msec; 1 = 350 msec; 2 = 700 msec. Default Values for zones 01 – 08 = 1 (350 msec)  
L = LEARNED RF INPUT Used with 5800 RF Loop Input Devices. Record transmitter input number.  
– 5 –  
*
*
TO PROGRAM SYSTEM STATUS, & RESTORE  
75  
RF XMTR LO BAT RST RPT CODE  
TEST RESTORE RPT CODE  
|
*
REPORT CODES ( 59Ð 76, & 89):  
*
*
76  
|
With a 3+1 or 4+1 Standard Format: Enter a code in the first  
box: 1–9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for B,  
"#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F.  
A "0" (not "#+10") in the first box will disable a report.  
A "0" (not "#+10") in the second box will result in automatic  
advance to the next field when programming.  
With an Expanded or 4+2 Format: Enter codes in both boxes  
(1st and 2nd digits) for 1–9, 0, or B–F, as described above.  
A "0" (not "#+10") in the second box will eliminate the ex-  
panded message for that report.  
A "0" (not "#+10") in both boxes will disable the report.  
With Ademco Contact ID Reporting: Enter any digit (other  
than "0") in the first box, to enable zone to report (entries in the  
second boxes will be ignored).  
A "0" (not "#+10") in the first box will disable the report.  
Examples:  
*
*
OUTPUT AND SYSTEM SETUP ( 80– 93)  
*
80 OUTPUT RELAYS AND  
POWERLINE CARRIER  
DEVICES  
Program only if  
Relays and/or  
Powerline Carrier  
devices are to be  
*
81 ZONE LISTS FOR OUTPUT  
used. See next page.  
DEVICES  
*
82  
83  
CUSTOM ALPHA EDITING: (Also entered from field  
*
56): See procedure in instructions.  
*
SEQUENTIAL LEARN MODE (Also entered from  
*
field 56): See procedure in instructions.  
*
89  
90  
EVENT LOG 80% FULL RPT CODE  
|
For Code 3 (single digit), enter:  
3
|
0
*
EVENT LOGGING  
0 = None; 1 = Alarm/Alarm Restore;  
2 = Trouble/Trouble Restore; 4 = Bypass/Bypass  
Restore; 8 = Open/Close.  
[3]  
For Code 3 2 (two digits), enter:  
3
|
2
For Code B 2 (Hexadecimal), enter: #+11 | 2  
Example: To select “Alarm/Alarm Restore”, and  
*
*
SYSTEM STATUS REPORT CODES ( 59– 68)  
“Open/Close”, enter 9 (1 + 8); To select all, enter #15.  
Note: System messages are logged when any non-  
zero selection is made.  
Default for all report codes = [00]  
*
59  
60  
61  
62  
63  
64  
65  
EXIT ERROR REPORT CODE  
TROUBLE REPORT CODE  
BYPASS REPORT CODE  
AC LOSS REPORT CODE  
LOW BAT REPORT CODE  
TEST REPORT CODE  
*
*
91  
OPTION SELECTION (AAV)  
0 = None; 4 = AAV;“0” for UL installations.  
[0]  
[0]  
*
*
*
*
*
*
|
|
|
|
|
92  
PHONE LINE MONITOR ENABLE  
0 = Not used  
1 = Keypad display when line is faulted  
2 = Keypad display plus keypad trouble sound  
t
t
3 = Same as “2”, plus Device #2 STARTS. If either  
partition is armed, external sounder activates also.  
Note: Device #2 must either be programmed to be  
*
STOPPED in field 80 or STOPPED by Code + # + 8 + 2.  
††  
††  
OPEN REPORT CODE  
Part. 1  
Part. 2  
*
*
93  
No. OF REPORTS IN ARMED PERIOD [0]  
0 = 10 Alarm/Alarm Restore Reports; 1 = Unlimited.  
“1” for UL installations.  
††  
*
66  
ARM AWAY/STAY RPT CODE Part. 1  
Part. 2  
*
*
DOWNLOAD INFORMATION ( 94, 95)  
AWAY STAY  
††  
94  
DOWNLOAD PHONE No.  
AWAY STAY  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2nd digit is automatically sent as the 2nd digit of the  
Enter up to 16 digits, 0–9; #+11 for '*'; #+12 for '#'; #+13 for  
a pause. Do not fill unused spaces. If fewer than 16 digits  
*
zone alarm report code programmed in 56, if  
expanded or 4+2 reporting is selected.  
*
entered, exit field by pressing (and press 95, if entering  
††  
2nd digit is automatically sent as the user number if  
expanded or 4+2 reporting is selected.  
*
*
next field). To clear entries from field, press 94 .  
Note: In UL installations, down loading may only be  
performed if a technician is at the site.  
*
*
67  
RF XMTR LOW BAT REPORT CODE  
CANCEL REPORT CODE  
|
|
*
95  
RING DET COUNT FOR DOWNLOADING[0]  
68  
0 = Disable Station Initiated Download; 1–14 = number  
of rings (1–9, # +10 =10, # +11 =11, # +12 =12,  
# +13 =13, # +14 =14); 15 = answering machine defeat  
(# +15 =15)  
*
*
RESTORE REPORT CODES ( 70– 76)  
Default for all restore report codes = [00]  
Note: Do not enter “0” if using 4285 Voice Module.  
*
70  
ALARM RESTORE RPT CODE  
2nd digit is automatically sent as the 2nd digit of  
*
96 INITIALIZES DOWNLOAD ID, SUBSCRIBER  
*
the zone alarm report code programmed in 56, if  
expanded or 4+2 reporting is selected.  
TROUBLE RESTORE RPT CODE  
BYPASS RESTORE RPT CODE  
ACCOUNT No. FOR INITIAL DOWNLOAD:  
No data entry required.  
*
*
71  
72  
73  
|
|
|
*
97 SETS ALL PROGRAM FIELDS TO DEFAULT  
VALUES: No data entry required.  
*
98  
Exits programming mode and prevents re-entry  
*
AC RESTORE RPT CODE  
t
*
by: Installer Code + 8+ 0 + 0. If 98 is used to  
exit programming mode, system must be  
powered down, and method 1 above used to  
enter the programming mode.  
*
74  
LOW BAT RESTORE RPT CODE  
t
|
*
99  
Exits programming mode and allows re-entry  
by: Installer Code + 8 + 0 + 0 or: Power-up, then  
press "*" and "#" within 50 seconds of power up.  
t Reports with Partition 1 Subscriber No.  
– 6 –  
*
*
OUTPUT RELAYS/POWERLINE CARRIER DEVICES WORKSHEET FOR 80, and 81.  
Applicable only if Relays and/or Powerline Carrier Devicess are to be used.  
*
80 OUTPUT DEVICES This is an interactive menu mode. Fill in the required data on the worksheet on below and follow  
the programming procedure in the installation manual as you enter the data during the displays and prompts that appear  
in sequence.  
*
Notes: 1. For Relays, field 25 must be programmed for a 4229 (Relays 01 and 02), OR for a 4204 (Relays 01 to 04).  
*
2. For Powerline Carrier devices, field 27 must be programmed with a House Code.  
3. Tampers of expansion units cannot be used to operate devices.  
S T A R T  
either or both  
S T O P  
either or both  
=
-
=
-
ZONE  
LIST  
(ZL)  
ZONE TYPE PART'N  
SYST OP'N No.  
RESTORE of ZONE TYPE PART'N  
ZONE LIST /SYST OP'N No.  
(ZL) (ZT) (P)  
DEVICE  
NUMBER  
ACTION  
(A)  
EVENT  
(EV)  
X-10  
SELECT  
(ZT)  
(P)  
OUTPUT RELAY  
OR P.L.C.D.* 01  
OUTPUT RELAY  
OR P.L.C.D.* 02  
OUTPUT RELAY  
OR P.L.C.D.* 03  
OUTPUT RELAY  
OR P.L.C.D.* 04  
P.L.C.D.*  
P.L.C.D.*  
P.L.C.D.*  
P.L.C.D.*  
05  
06  
07  
08  
+* P.L.C.D. = Powerline Carrier Device (X-10).  
Where:  
X-10 SELECT  
A = DEVICE ACTION 0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.  
=
Powerline Carrier Device Enter “1” if Powerline Carrier Device is being used, enter “0” if relay is being used.  
EV = EVENT  
0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.  
*
Z L = ZONE LIST 1, 2, or 3 (from Field 81) or 0 = Not Used.  
"START" ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, device action will START.  
"STOP" RESTORE of ZONE LIST: Upon restore of ALL zones on this list, device action will STOP. It  
need not be same list as used for START.  
NOTE: Do not use input type "BR" transmitters in a zone list to STOP a relay action, since these  
transmitters do not send restores.  
ZT = ZONE TYPE/SYSTEM OPERATION  
Choices for Zone Types are:  
00 = Not Used  
06 = 24 Hr Silent  
07 = 24 Hr Audible  
08 = 24 Hr Aux  
09 = Fire Trouble  
10 = Interior w/Delay  
24= Silent Burglary  
Note: Any zone in "ZT" going into alarm,  
01 = Entry/Exit#1  
fault, or trouble will actuate relay.  
02 = Entry/Exit#2  
03 = Perimeter  
04 = Interior Follower  
05 = Trouble Day/Alarm Night  
Any zone of that type that restores  
will stop relay action.  
Choices for System Operation are:  
20 = Arming–Stay  
38 = Chime  
52 = Kissoff  
58 = Duress  
21 = Arming–Away  
39 = Any Fire Alarm  
40 = Bypassing  
22 = Disarming (Code + OFF)  
31 = End of Exit Time  
32 = Start of Entry Time  
33 = Any Burglary Alarm  
36 = **At Bell Timeout***  
41 = **AC Power Failure  
42 = **System Battery Low  
43 = Communication Failure  
Note: In normal operation mode:  
** Use 0 (Any) for Partition No. (P) entry.  
*** Or at Disarming, whichever occurs earlier.  
Code + # + 7 + N Key Entry starts Device N.  
Code + # + 8 + N Key Entry stops Device N.  
P = PARTITION No. 1, 2, or 0 for Any  
– 7 –  
*
81  
ZONE LISTS FOR OUTPUT DEVICES This is an interactive mode. Fill in the required data on the worksheet  
below and follow the procedure in the installation manual as you enter the data during the displays and prompts that  
appear in sequence.  
Note:  
Record desired zone numbers below. More or fewer boxes than shown may be needed, since any list may  
include any or all of system's zone numbers.  
Zone List 1: Started or stopped by zone numbers (enter 00 to end entries).  
,
,
,
,
,
,
,
,
,
,
,
...etc.  
...etc.  
Zone List 2: Started or stopped by zone numbers (enter 00 to end entries).  
,
,
,
,
,
,
,
Zone List 3: Started or stopped by zone numbers AND/OR assignment of Chime zones (enter 00 to end entries)  
,
,
,
,
,
,
,
,
,
,
,
,
...etc.  
...etc.  
Zone List 4: Assignment of common lobby zones (enter 00 to end entries).  
,
,
,
,
,
,
SPECIAL MESSAGES  
OC = OPEN CIRCUIT (no communication between Console and Control).  
EE or ENTRY ERROR = ERROR (invalid field number entered; re-enter valid field number).  
After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds. This  
will revert to READY in appx. 1 minute, which allows PIRS, etc. to stabilize. To bypass this delay, press: [#] + [0].  
If E4 or E8 appears, more zones than the expansion units can handle have been programmed. Correct the programming and  
then completely de-power and re-power the control to clear this indication and remove the disable indication.  
TO ENTER PROGRAMMING MODE:  
1. POWER UP, then depress [*] and [#] both at once, within 50 seconds of powering up.  
OR  
2. Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0.  
OR  
3. If different Installer Code is programmed, key: New Installer Code + 8 + 0 + 0.  
*
(if 98 was used to exit previously, method 1 above must be used to enter the program mode again)  
TO EXIT PROGRAMMING MODE:  
*
*
98 Exits programming mode and prevents re-entry by: Installer Code + 8+ 0 + 0. If 98 is used to exit programming  
mode, system must be powered down, and method 1 above used to enter the programming mode.  
*
99 Exits programming mode and allows re-entry by: Installer Code + 8 + 0 + 0 or: Power-up, then press "*" and "#"  
within 50 seconds of power up.  
®
ALARM DEVICE MANUFACTURING CO.  
A DIVISION OF PITTWAY CORPORATION  
165 Eileen Way, Syosset, New York 11791  
Copyright © 1997 PITTWAY CORPORATION  

Sharp Ar M280n User Manual
Samsung Am C610 User Manual
Quasar Hq2050ph User Manual
Panasonic Kx Tg5672 User Manual
MAKITA UH008G User Manual
D LINK DAP X1870 User Manual
Dirt Devil Power Max Pet User Manual
CRAFTSMAN 917.386620 User Manual
BLACK DECKER HSV420J42 User Manual
ASUS UX305L User Manual