Print Form  
Split System Submittal Data  
System: 42TW72R  
Indoor/Outdoor: THW4272R/C4272R  
Ceiling Suspended Air Conditioner  
Job Name:  
Location:  
Approval:  
Date:  
Engineer:  
Construction:  
Unit #:  
Drawing #:  
Submitted to:  
Submitted by:  
Reference:  
General Data (at 230V)  
Power  
Circuit Ampacity  
Fuse Size, Max.  
V/PH/Hz  
(A)  
(A)  
230/208/1/60  
15-40 Indoor-Outdoor  
15-40 Indoor-Outdoor  
Refrigerant  
Lbs. - R410a (outdoor unit)  
Control  
R410A  
7.94  
Electric Expansion Valve  
Compressor  
No. used  
R.L. Amps - L.R.  
Crankcase Heater  
DC Rotary Inverter  
1
18.1-31.0  
-
Flare  
165  
Connection  
(A)  
(W)  
Line Length, Max  
Lift Difference, Max  
Line Size  
50 (Outdoor lower), 100 (Outdoor higher)  
Outdoor Unit  
Fan type  
Dia. (in.) - No. Speeds  
Type Drive - No. Speeds  
No. Poles  
(in. O.D. Discharge)  
(in. O.D. Suction)  
3/8”  
5/8”  
Line Size  
Propeller  
18-7/64-2  
Direct Inverter  
8 - 830  
Dimensions  
(in.)  
H x W x D  
Indoor Unit  
(RPM)  
(W)  
(Uncrated)  
(Crated)  
9-7/16 x 62-1/32 x 26-3/8  
12-15/32 x 66-1/16 x 31-1/6  
48-7/16 x 37 x 13-3/8  
No. Motors  
2-90  
(High)  
3531  
CFM  
Outdoor Unit  
(Uncrated)  
(A)  
19.7  
F.L. Amps  
(Crated)  
52-3/8 x 39-31/32 x 16-3/32  
Aluminum Fin & Copper Pipe  
Coil Type  
Weight  
Net  
Shipping  
Indoor  
84  
Outdoor  
220  
Slit Plate - Inner Rifed  
Fin Type - Pipe Type  
Rows - F.P.I.  
Face Area  
(lbs.)  
(lbs.)  
2-12.7  
11.62  
3/8”  
97  
240  
(sq.ft.)  
(in.)  
Tube Size  
Indoor  
14.8  
Outdoor  
19.5  
Shipping Volume  
(cu.ft.)  
Indoor Unit  
Fan type  
Dia. & Length (in.) - No. Speeds  
No. Speeds  
No. Poles  
No. Motors  
Performance Data @ ARI Standard Conditions (230V)  
Cooling  
Centrifugal  
5-29/32 - 4  
3 & Auto  
Total Capacity  
Sensible Capacity  
Latent Capacity  
SEER  
(BTU/H)  
(BTU/H)  
(BTU/H)  
39,000 (9,500-39,000)  
(RPM, High)  
(W)  
(HI/Med/Lo)  
4-1099  
1-100  
1130/950/775  
23,560  
15,440  
15.6  
CFM  
Indoor Sound Rating  
F.L. Amps  
Dehumidification  
Amps  
(Pints/H)  
(A)  
12.6  
21.1/23.3  
(Hi) (dB-A)  
(A)  
44  
0.8  
Power Inputs  
Outdoor Sound Rating  
(W)  
4,140/4,140  
53  
Coil Type  
Aluminum Fin & Copper Tube  
(dB-A)  
Fin Type - Pipe Type  
Rows - F.P.I.  
Face Area  
Slit Plate - Inner Rifed  
3-14.9  
3.51  
(sq.ft.)  
Tube Size  
Drain Connection Size  
(in.)  
(in.)  
9/32”  
(1-1/4)  

Whirlpool Ar0700xa User Manual
Toshiba Air Conditioner Rav Sm804bt Tr User Manual
Rocketfish Rf Gwii1126 User Manual
Nec Rih 3267 User Manual
John Deere L107 User Manual
HP A7173A User Manual
Hampton Bay Sinclair 44 User Manual
CREATIVE OUTLIER AIR V2 EF0900 C User Manual
CRAFTSMAN 316.796140 User Manual
BLACK DECKER PHV1800 User Manual