PACKAGE AIR CONDITIONERS
FORM NO. S11-933 REV. 2
Supersedes Form No. S11-933 Rev. 1
RSNA-B SUPER HIGH EFFICIENCY 13-SEER SERIES
NOMINAL SIZES 2-5 TONS [7.0-17.6 kW]
UNIT FEATURES & BENEFITS—RSNA-B
These quality features are included in the Rheem
Package Air Conditioner
5
3
UNIT FEATURES & BENEFITS—RSNA-B SERIES
[
] Designates Metric Conversions
Features Below Correspond to Photos on Page 3
1. All models feature Copeland® Scroll® compressors for maxi-
mum efficiency and quiet operation.
8. Refrigerant connections are conveniently located for easy
service diagnostics.
2. Louvered condenser compartment for protecting the coil
against yard hazards and/or weather extremes.
9. Condenser and evaporator coils feature enhanced fins
for better heat transfer and rifled copper tubing for
greater efficiency.
3. One-piece top with a drip lip to help keep water off of the unit
sides.
10. Supplemental electric heat strips up to 15 kW are available
(field or factory installed) for periods of extreme cold temper-
atures. Single point wiring makes installation even easier.
4. Supply and return air openings feature a one-inch tall flange
to prevent water migration into the ductwork.
11. All units feature an internal trap on the condensate line elimi-
nating the need for installing an on-site external trap.
5. Access panels have “weep holes” and channels to further
help manage water run-off.
12. Easily accessible control box.
6. Side and down discharge options available on all models.
7. Easily accessible blower section complete with slide-out
blower.
4
MODEL IDENTIFICATION—RSNA-B SERIES
R S N A — B 036 J K 010 X X
Factory Installed Options
(See Next Page)
Heating Capacity (Factory Installed)
000 = No Resistance Heat
005 = 05 KW Resistance Heat (018-030)
010 = 10 KW Resistance Heat (024-048)
015 = 15 KW Resistance Heat (036-048)
Drive Package
K = Direct Drive
Electrical Designation
J = 208-230V—1PH—60 Hz
C= 208-230V—3PH—60 Hz
Cooling Capacity (BTUH) [kW]
024 = 24,000 [7.03]
030 = 30,000 [8.79]
036 = 36,000 [10.55]
042 = 42,000 [12.31]
048 = 48,000 [14.07]
060 = 60,000 [17.59]
Future Technical Variations
Design Series
B = 2nd Design
Efficiency Designation
N = 13 SEER Super High Efficiency
Product Classification
S = Package Air Conditioner
Tradebrand
R = Rheem
[
] Designates Metric Conversions
5
OPTIONS—RSNA-B SERIES
Instructions for Factory Installed Option(s) Selection
Note: Two characters following the model number will be utilized to designate a factory-installed option or com-
bination of options. If no factory option(s) is required, nothing follows the model number.
Step 1. After a basic rooftop model is selected, choose a two-character option code from the FACTORY
INSTALLED OPTION SELECTION TABLE.
FACTORY INSTALLED OPTION CODES
Option
Side Flow
Code
AA
AK
No Option
x
Example: RSNA-B036JK000XX (where XX is factory installed option)
Example: No Options
RSNA-B036JK000
Example: Options with Sideflow
RSNA-B036JK000AK
Note: Factory installed economizer is not available on these models.
6
GENERAL DATA—RSNA-B SERIES
NOMINAL SIZES 2-5TONS [7.0-17.6 kW]
Model RSNA-B Series
Cooling Performance1
Gross Cooling Capacity Btu [kW]
EER/SEER2
B024JK
B030JK
B036CK
B036JK
CONTINUED
37,400 [10.96]
11.7/13
24,800 [7.27]
11.8/13
31,200 [9.14]
11.1/13
37,400 [10.96]
11.7/13
Nominal CFM/ARI Rated CFM [L/s]
ARI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Compressor
800/800 [378/378]
24,000 [7.03]
17,171 [5.03]
6,829 [2]
1000/1000 [472/472]
30,000 [8.79]
20,984 [6.15]
9,016 [2.64]
2.7
1200/1200 [566/566]
36,000 [10.55]
25,736 [7.54]
10,264 [3.01]
3.07
1200/1200 [566/566]
36,000 [10.55]
25,736 [7.54]
10,264 [3.01]
3.07
2.04
No./Type
1/Copeland Scroll
76
1/Copeland Scroll
76
1/Copeland Scroll
76
1/Copeland Scroll
76
Outdoor Sound Rating (dB)3
Outdoor Coil—Fin Type
Tube Type
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Indoor Coil—Fin Type
Tube Type
0.375 [9.5]
10.56 [0.98]
1 / 18 [7]
Louvered
Rifled
0.375 [9.5]
10.56 [0.98]
1 / 18 [7]
Louvered
Rifled
0.375 [9.5]
14.8 [1.37]
1 / 22 [9]
Louvered
Rifled
0.375 [9.5]
14.8 [1.37]
1 / 22 [9]
Louvered
Rifled
Tube Size in. [mm]
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan—Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
0.375 [9.5]
5.54 [0.51]
2 / 15 [6]
TX Valves
1/0.75 [19.05]
Propeller
1/22 [558.8]
Direct/1
0.375 [9.5]
5.54 [0.51]
2 / 15 [6]
TX Valves
1/0.75 [19.05]
Propeller
1/22 [558.8]
Direct/1
0.375 [9.5]
5.54 [0.51]
2 / 15 [6]
TX Valves
1/0.75 [19.05]
Propeller
1/22 [558.8]
Direct/1
0.375 [9.5]
5.54 [0.51]
2 / 15 [6]
TX Valves
1/0.75 [19.05]
Propeller
1/22 [558.8]
Direct/1
2500 [1180]
1 at 1/5 HP
1075
2500 [1180]
1 at 1/5 HP
1075
2700 [1274]
1 at 1/5 HP
1075
2700 [1274]
1 at 1/5 HP
1075
No. Motors/HP
Motor RPM
Indoor Fan—Type
FC Centrifugal
1/9x7 [228.6x177.8]
Direct/2
FC Centrifugal
1/10x9 [254x228.6]
Direct/3
FC Centrifugal
1/10x9 [254x228.6]
Direct/3
FC Centrifugal
1/10x9 [254x228.6]
Direct/3
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
1
1
1
1
Motor HP
1/4
1/2
1/2
1/2
Motor RPM
1075
1075
1075
1075
Motor Frame Size
48
48
48
48
Filter—Type
Field Supplied
No
Field Supplied
No
Field Supplied
No
Field Supplied
No
Furnished
(No.) Size Recommended in. [mm]
Refrigerant Charge Oz. [g]
Weights
(1)1x20x20 [25x508x508] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
69.6 [1973]
72 [2041]
83.2 [2359]
83.2 [2359]
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
See Page 10 for Notes.
370 [168]
379 [172]
379 [178]
388 [176]
392 [178]
401 [182]
[
392 [178]
401 [182]
] Designates Metric Conversions
7
GENERAL DATA—RSNA-B SERIES
NOMINAL SIZES 2-5TONS [7.0-17.6 kW]
Model RSNA-B Series
Cooling Performance1
Gross Cooling Capacity Btu [kW]
EER/SEER2
B042CK
B042JK
B048CK
B048JK
CONTINUED
42,500 [12.45]
11.5/13
42,500 [12.45]
11.5/13
50,500 [14.8]
11.6/13
50,500 [14.8]
11.6/13
Nominal CFM/ARI Rated CFM [L/s]
ARI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Compressor
1400/1350 [661/637]
41,000 [12.01]
28,511 [8.35]
12,489 [3.66]
3.57
1400/1350 [661/637]
41,000 [12.01]
28,511 [8.35]
12,489 [3.66]
3.57
1600/1600 [755/755]
48,500 [14.21]
34,516 [10.11]
13,984 [4.1]
4.18
1600/1600 [755/755]
48,500 [14.21]
34,516 [10.11]
13,984 [4.1]
4.18
No./Type
1/Copeland Scroll
76
1/Copeland Scroll
76
1/Copeland Scroll
78
1/Copeland Scroll
78
Outdoor Sound Rating (dB)3
Outdoor Coil—Fin Type
Tube Type
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Louvered
Rifled
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Indoor Coil—Fin Type
Tube Type
0.375 [9.5]
16.65 [1.55]
1 / 22 [9]
Louvered
Rifled
0.375 [9.5]
16.65 [1.55]
1 / 22 [9]
Louvered
Rifled
0.375 [9.5]
16.23 [1.51]
2 / 22 [9]
Louvered
Rifled
0.375 [9.5]
16.23 [1.51]
2 / 22 [9]
Louvered
Rifled
Tube Size in. [mm]
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan—Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
0.375 [9.5]
7.39 [0.69]
2 / 15 [6]
TX Valves
1/0.75 [19.05]
Propeller
1/22 [558.8]
Direct/1
0.375 [9.5]
7.39 [0.69]
2 / 15 [6]
TX Valves
1/0.75 [19.05]
Propeller
1/22 [558.8]
Direct/1
0.375 [9.5]
7.39 [0.69]
2 / 15 [6]
TX Valves
1/0.75 [19.05]
Propeller
1/22 [558.8]
Direct/1
0.375 [9.5]
7.39 [0.69]
2 / 15 [6]
TX Valves
1/0.75 [19.05]
Propeller
1/22 [558.8]
Direct/1
3500 [1652]
1 at 1/3 HP
1075
3500 [1652]
1 at 1/3 HP
1075
3300 [1557]
1 at 1/3 HP
1075
3300 [1557]
1 at 1/3 HP
1075
No. Motors/HP
Motor RPM
Indoor Fan—Type
FC Centrifugal
1/10x9 [254x228.6]
Direct/3
FC Centrifugal
1/10x9 [254x228.6]
Direct/3
FC Centrifugal
1/10x9 [254x228.6]
Direct/3
FC Centrifugal
1/10x9 [254x228.6]
Direct/3
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
1
1
1
1
Motor HP
1/2
1/2
3/4
3/4
Motor RPM
1075
1075
1075
1075
Motor Frame Size
48
48
48
48
Filter—Type
Field Supplied
No
Field Supplied
No
Field Supplied
No
Field Supplied
No
Furnished
(No.) Size Recommended in. [mm]
Refrigerant Charge Oz. [g]
Weights
(1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
104 [2948]
104 [2948]
153.6 [4355]
153.6 [4355]
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
See Page 10 for Notes.
447 [203]
456 [207]
447 [203]
456 [207]
499 [226]
508 [230]
[
499 [226]
508 [230]
] Designates Metric Conversions
8
GENERAL DATA—RSNA-B SERIES
NOMINAL SIZES 2-5TONS [7.0-17.6 kW]
Model RSNA-B Series
Cooling Performance1
Gross Cooling Capacity Btu [kW]
EER/SEER2
B060CK
B060JK
60,000 [17.58]
11.1/13
60,000 [17.58]
11.1/13
Nominal CFM/ARI Rated CFM [L/s]
ARI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Compressor
2000/1850 [897/873]
58,000 [16.99]
40,561 [11.88]
17,439 [5.11]
5.2
2000/1850 [897/873]
58,000 [16.99]
40,561 [11.88]
17,439 [5.11]
5.2
No./Type
1/Copeland Scroll
78
1/Copeland Scroll
78
Outdoor Sound Rating (dB)3
Outdoor Coil—Fin Type
Tube Type
Louvered
Rifled
Louvered
Rifled
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Indoor Coil—Fin Type
Tube Type
0.375 [9.5]
16.23 [1.51]
2 / 22 [9]
Louvered
Rifled
0.375 [9.5]
16.23 [1.51]
2 / 22 [9]
Louvered
Rifled
Tube Size in. [mm]
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan—Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
0.375 [9.5]
7.39 [0.69]
2 / 15 [6]
TX Valves
1/0.75 [19.05]
Propeller
1/22 [558.8]
Direct/1
0.375 [9.5]
7.39 [0.69]
2 / 15 [6]
TX Valves
1/0.75 [19.05]
Propeller
1/22 [558.8]
Direct/1
3300 [1557]
1 at 1/3 HP
1075
3300 [1557]
1 at 1/3 HP
1075
No. Motors/HP
Motor RPM
Indoor Fan—Type
FC Centrifugal
1/10x9 [254x228.6]
Direct/2
FC Centrifugal
1/10x9 [254x228.6]
Direct/2
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
1
1
Motor HP
1
1
Motor RPM
1075
1075
Motor Frame Size
48
48
Filter—Type
Field Supplied
No
Field Supplied
No
Furnished
(No.) Size Recommended in. [mm]
Refrigerant Charge Oz. [g]
Weights
(1)1x24x30 [25x610x762] (1)1x24x30 [25x610x762]
145.6 [4128]
145.6 [4128]
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
See Page 10 for Notes.
521 [236]
530 [240]
521 [236]
530 [240]
[
] Designates Metric Conversions
9
GENERAL DATA—RSNA-B SERIES
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does
not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable
for operation to Ϯ20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment
certification program, which is based on ARI Standard 210/240 or 360.
2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270.
[
] Designates Metric Conversions
10
SYSTEMS PERFORMANCE—RSNA-B SERIES
GROSS SYSTEMS PERFORMANCE DATA—RSNA-B024
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE
CFM [L/s]
DR ➀
71°F [21.7°C]
800 [378]
.20
67°F [19.4°C]
800 [378]
.20
63°F [17.2°C]
800 [378]
.20
880 [415]
.21
680 [321]
.18
880 [415]
.21
680 [321]
.18
880 [415]
.21
680 [321]
.18
Total BTUH [kW] 28.9 [8.47]
28.4 [8.32]
15.4 [4.51]
1.3
27.6 [8.09]
14.4 [4.22]
1.3
27.3 [8.00]
19.5 [5.71]
1.3
26.8 [7.85]
18.6 [5.45]
1.3
26.1 [7.65]
17.3 [5.07]
1.3
25.0 [7.33]
22.0 [6.45]
1.3
24.6 [7.21]
21.1 [6.18]
1.3
23.9 [7.00]
19.6 [5.74]
1.3
75
[23.9]
Sens BTUH [kW] 16.2 [4.75]
Power
1.4
O
U
T
D
O
O
R
Total BTUH [kW] 28.9 [8.47]
28.4 [8.32]
15.4 [4.51]
1.5
27.6 [8.09]
14.3 [4.19]
1.4
27.2 [7.97]
19.5 [5.71]
1.5
26.8 [7.85]
18.6 [5.45]
1.4
26.0 [7.62]
17.3 [5.07]
1.4
25.0 [7.33]
22.0 [6.45]
1.4
24.5 [7.18]
21.0 [6.15]
1.4
23.9 [7.00]
19.6 [5.74]
1.4
80
Sens BTUH [kW] 16.1 [4.72]
[26.7]
Power
1.5
Total BTUH [kW] 28.5 [8.35]
28.0 [8.21]
15.3 [4.48]
1.6
27.2 [7.97]
14.2 [4.16]
1.5
26.9 [7.88]
19.3 [5.66]
1.6
26.4 [7.74]
18.5 [5.42]
1.6
25.7 [7.53]
17.2 [5.04]
1.5
24.6 [7.21]
21.9 [6.42]
1.5
24.1 [7.06]
20.9 [6.13]
1.5
23.5 [6.89]
19.5 [5.71]
1.5
85
[29.4]
Sens BTUH [kW] 16.0 [4.69]
Power
1.6
D
R
Y
Total BTUH [kW] 27.8 [8.15]
27.3 [8.00]
15.1 [4.43]
1.7
26.6 [7.80]
14.0 [4.10]
1.7
26.2 [7.68]
19.1 [5.60]
1.7
25.7 [7.53]
18.3 [5.36]
1.7
25.0 [7.33]
17.0 [4.98]
1.7
23.9 [7.00]
21.7 [6.36]
1.6
23.5 [6.89]
20.7 [6.07]
1.6
22.8 [6.68]
19.3 [5.66]
1.6
90
[32.2]
Sens BTUH [kW] 15.8 [4.63]
B
U
L
Power
1.7
Total BTUH [kW] 27.0 [7.91]
26.5 [7.77]
14.8 [4.34]
1.8
25.8 [7.56]
13.8 [4.04]
1.8
25.3 [7.41]
18.9 [5.54]
1.8
24.8 [7.27]
18.0 [5.28]
1.8
24.2 [7.09]
16.8 [4.92]
1.8
23.0 [6.74]
21.4 [6.27]
1.8
22.6 [6.62]
20.5 [6.01]
1.7
22.0 [6.45]
19.0 [5.57]
1.7
95
[35]
B
Sens BTUH [kW] 15.5 [4.54]
Power
1.8
T
E
M
P
E
R
A
T
Total BTUH [kW] 26.0 [7.62]
25.5 [7.47]
14.5 [4.25]
1.9
24.8 [7.27]
13.5 [3.96]
1.9
24.3 [7.12]
18.5 [5.42]
1.9
23.9 [7.00]
17.7 [5.19]
1.9
23.2 [6.80]
16.4 [4.81]
1.9
22.1 [6.48]
21.1 [6.18]
1.9
21.7 [6.36]
20.1 [5.89]
1.9
21.1 [6.18]
18.7 [5.48]
1.8
100
[37.8]
Sens BTUH [kW] 15.2 [4.45]
Power
1.9
Total BTUH [kW] 25.0 [7.33]
24.5 [7.18]
14.1 [4.13]
2.0
23.9 [7.00]
13.1 [3.84]
2.0
23.3 [6.83]
18.1 [5.30]
2.0
22.9 [6.71]
17.3 [5.07]
2.0
22.3 [6.54]
16.1 [4.72]
2.0
21.1 [6.18]
20.6 [6.04]
2.0
20.7 [6.07]
19.7 [5.77]
2.0
20.1 [5.89]
18.3 [5.36]
1.9
105
[40.6]
Sens BTUH [kW] 14.7 [4.31]
Power
2.0
U
R
E
Total BTUH [kW] 24.1 [7.06]
23.7 [6.95]
13.6 [3.99]
2.1
23.0 [6.74]
12.7 [3.72]
2.1
22.4 [6.56]
17.6 [5.16]
2.1
22.0 [6.45]
16.8 [4.92]
2.1
21.4 [6.27]
15.6 [4.57]
2.1
20.2 [5.92]
20.1 [5.89]
2.1
19.8 [5.80]
19.2 [5.63]
2.1
19.3 [5.66]
17.9 [5.25]
2.1
110
[43.3]
Sens BTUH [kW] 14.3 [4.19]
°F
[°C]
Power
2.1
Total BTUH [kW] 23.3 [6.83]
22.9 [6.71]
13.1 [3.84]
2.2
22.3 [6.54]
12.2 [3.58]
2.2
21.7 [6.36]
17.0 [4.98]
2.3
21.3 [6.24]
16.3 [4.78]
2.2
20.7 [6.07]
15.1 [4.43]
2.2
19.4 [5.69]
19.4 [5.69]
2.2
19.1 [5.60]
18.7 [5.48]
2.2
18.5 [5.42]
17.4 [5.10]
2.2
115
[46.1]
Sens BTUH [kW] 13.7 [4.02]
Power
2.3
GROSS SYSTEMS PERFORMANCE DATA—RSNA-B030
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE
CFM [L/s]
DR ➀
71°F [21.7°C]
1000 [472]
.23
67°F [19.4°C]
1000 [472]
.23
63°F [17.2°C]
1000 [472]
.23
1100 [519]
.24
850 [401]
.21
1100 [519]
.24
850 [401]
.21
1100 [519]
.24
850 [401]
.21
Total BTUH [kW] 37.6 [11.02] 36.9 [10.81] 35.9 [10.52] 35.0 [10.26] 34.4 [10.08] 33.4 [9.79]
33.6 [9.85]
27.2 [7.97]
1.9
33.0 [9.67]
26.0 [7.62]
1.9
32.1 [9.41]
24.2 [7.09]
1.9
75
[23.9]
Sens BTUH [kW] 21.3 [6.24] 20.3 [5.95] 18.9 [5.54] 25.2 [7.39] 24.1 [7.06] 22.4 [6.56]
Power
1.9
1.9
1.9
1.9
1.9
1.9
O
U
T
D
O
O
R
Total BTUH [kW] 37.1 [10.87] 36.4 [10.67] 35.4 [10.37] 34.5 [10.11] 33.9 [9.94] 32.9 [9.64]
33.1 [9.70]
26.7 [7.83]
2.0
32.5 [9.52]
25.5 [7.47]
2.0
31.6 [9.26]
23.8 [6.98]
2.0
80
Sens BTUH [kW] 20.8 [6.10] 19.9 [5.83] 18.5 [5.42] 24.7 [7.24] 23.6 [6.92] 22.0 [6.45]
[26.7]
Power
2.1
2.0
2.0
2.0
2.0
2.0
Total BTUH [kW] 36.3 [10.64] 35.6 [10.43] 34.7 [10.17] 33.7 [9.88] 33.1 [9.70] 32.2 [9.44]
32.3 [9.47]
26.2 [7.68]
2.1
31.7 [9.29]
25.1 [7.36]
2.1
30.9 [9.06]
23.3 [6.83]
2.1
85
[29.4]
Sens BTUH [kW] 20.3 [5.95] 19.4 [5.69] 18.0 [5.28] 24.2 [7.09] 23.1 [6.77] 21.5 [6.30]
Power
2.2
2.2
2.1
2.2
2.1
2.1
D
R
Y
Total BTUH [kW] 35.3 [10.35] 34.7 [10.17] 33.8 [9.91] 32.8 [9.61] 32.2 [9.44] 31.3 [9.17]
31.4 [9.20]
25.7 [7.53]
2.3
30.8 [9.03]
24.6 [7.21]
2.2
30.0 [8.79]
22.9 [6.71]
2.2
90
[32.2]
Sens BTUH [kW] 19.8 [5.80] 18.9 [5.54] 17.6 [5.16] 23.7 [6.95] 22.6 [6.62] 21.1 [6.18]
B
U
L
Power
2.3
2.3
2.2
2.3
2.2
2.2
Total BTUH [kW] 34.3 [10.05] 33.7 [9.88] 32.8 [9.61] 31.7 [9.29] 31.2 [9.14] 30.3 [8.88]
30.3 [8.88]
25.2 [7.39]
2.4
29.8 [8.73]
24.1 [7.06]
2.4
29.0 [8.50]
22.4 [6.56]
2.3
95
[35]
B
Sens BTUH [kW] 19.3 [5.66] 18.4 [5.39] 17.1 [5.01] 23.2 [6.80] 22.1 [6.48] 20.6 [6.04]
Power
2.4
2.4
2.4
2.4
2.4
2.3
T
E
M
P
E
R
A
T
Total BTUH [kW] 33.2 [9.73] 32.6 [9.55] 31.7 [9.29] 30.6 [8.97] 30.1 [8.82] 29.3 [8.59]
29.2 [8.56]
24.7 [7.24]
2.5
28.7 [8.41]
23.6 [6.92]
2.5
27.9 [8.18]
21.9 [6.42]
2.4
100
[37.8]
Sens BTUH [kW] 18.7 [5.48] 17.9 [5.25] 16.6 [4.86] 22.7 [6.65] 21.6 [6.33] 20.1 [5.89]
Power
2.5
2.5
2.5
2.5
2.5
2.4
Total BTUH [kW] 32.1 [9.41] 31.6 [9.26] 30.7 [9.00] 29.6 [8.67] 29.0 [8.50] 28.3 [8.29]
28.2 [8.26]
24.2 [7.09]
2.6
27.7 [8.12]
23.1 [6.77]
2.6
26.9 [7.88]
21.5 [6.30]
2.5
105
[40.6]
Sens BTUH [kW] 18.2 [5.33] 17.4 [5.10] 16.2 [4.75] 22.1 [6.48] 21.2 [6.21] 19.7 [5.77]
Power
2.6
2.6
2.6
2.6
2.6
2.6
U
R
E
Total BTUH [kW] 31.2 [9.14] 30.6 [8.97] 29.8 [8.73] 28.6 [8.38] 28.1 [8.24] 27.3 [8.00]
27.2 [7.97]
23.7 [6.95]
2.7
26.7 [7.83]
22.6 [6.62]
2.7
26.0 [7.62]
21.0 [6.15]
2.7
110
[43.3]
Sens BTUH [kW] 17.7 [5.19] 16.9 [4.95] 15.7 [4.60] 21.6 [6.33] 20.7 [6.07] 19.2 [5.63]
°F
[°C]
Power
2.7
2.7
2.7
2.7
2.7
2.7
Total BTUH [kW] 30.4 [8.91] 29.8 [8.73] 29.0 [8.50] 27.8 [8.15] 27.3 [8.00] 26.6 [7.80]
26.4 [7.74]
23.2 [6.80]
2.8
25.9 [7.59]
22.1 [6.48]
2.8
25.2 [7.39]
20.6 [6.04]
2.8
115
[46.1]
Sens BTUH [kW] 17.2 [5.04] 16.5 [4.84] 15.3 [4.48] 21.1 [6.18] 20.2 [5.92] 18.8 [5.51]
Power
2.9
2.8
2.8
2.8
2.8
2.8
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
[
] Designates Metric Conversions
11
SYSTEMS PERFORMANCE—RSNA-B SERIES
GROSS SYSTEMS PERFORMANCE DATA—RSNA-B036
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE
CFM [L/s]
DR ➀
71°F [21.7°C]
1200 [566]
.20
67°F [19.4°C]
1200 [566]
.20
63°F [17.2°C]
1200 [566]
.20
1320 [623]
.21
1020 [481]
.17
1320 [623]
.21
1020 [481]
.17
1320 [623]
.21
1020 [481]
.17
Total BTUH [kW] 44.4 [13.01] 43.6 [12.78] 42.4 [12.43] 41.3 [12.10] 40.6 [11.90] 39.5 [11.58] 39.6 [11.61] 38.9 [11.40] 37.8 [11.08]
75
[23.9]
Sens BTUH [kW] 25.5 [7.47] 24.4 [7.15] 22.7 [6.65] 30.4 [8.91] 29.1 [8.53] 27.0 [7.91] 31.4 [9.20] 30.0 [8.79] 27.9 [8.18]
Power
2.2
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
O
U
T
D
O
O
R
Total BTUH [kW] 43.6 [12.78] 42.8 [12.54] 41.7 [12.22] 40.5 [11.87] 39.8 [11.66] 38.7 [11.34] 38.7 [11.34] 38.0 [11.14] 37.0 [10.84]
80
Sens BTUH [kW] 25.0 [7.33] 23.9 [7.00] 22.2 [6.51] 29.9 [8.76] 28.6 [8.38] 26.6 [7.80] 30.8 [9.03] 29.5 [8.65] 27.4 [8.03]
[26.7]
Power
2.3
2.3
2.2
2.3
2.3
2.2
2.3
2.3
2.2
Total BTUH [kW] 42.8 [12.54] 42.1 [12.34] 40.9 [11.99] 39.7 [11.63] 39.0 [11.43] 38.0 [11.14] 38.0 [11.14] 37.3 [10.93] 36.3 [10.64]
85
[29.4]
Sens BTUH [kW] 24.5 [7.18] 23.4 [6.86] 21.8 [6.39] 29.4 [8.62] 28.1 [8.24] 26.1 [7.65] 30.3 [8.88] 29.0 [8.50] 27.0 [7.91]
Power
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
D
R
Y
Total BTUH [kW] 42.0 [12.31] 41.3 [12.10] 40.2 [11.78] 38.9 [11.40] 38.3 [11.22] 37.2 [10.90] 37.2 [10.90] 36.5 [10.70] 35.5 [10.40]
90
[32.2]
Sens BTUH [kW] 24.0 [7.03] 22.9 [6.71] 21.3 [6.24] 28.9 [8.47] 27.6 [8.09] 25.7 [7.53] 29.9 [8.76] 28.5 [8.35] 26.5 [7.77]
B
U
L
Power
2.6
2.5
2.5
2.6
2.5
2.5
2.5
2.5
2.5
Total BTUH [kW] 41.1 [12.05] 40.4 [11.84] 39.3 [11.52] 38.0 [11.14] 37.4 [10.96] 36.3 [10.64] 36.3 [10.64] 35.6 [10.43] 34.7 [10.17]
95
[35]
B
Sens BTUH [kW] 23.5 [6.89] 22.4 [6.56] 20.9 [6.13] 28.4 [8.32] 27.1 [7.94] 25.2 [7.39] 29.3 [8.59] 28.0 [8.21] 26.0 [7.62]
Power
2.7
2.7
2.6
2.7
2.7
2.6
2.7
2.7
2.6
T
E
M
P
E
R
A
T
Total BTUH [kW] 40.0 [11.72] 39.3 [11.52] 38.2 [11.20] 36.9 [10.81] 36.3 [10.64] 35.3 [10.35] 35.2 [10.32] 34.5 [10.11] 33.6 [9.85]
100
[37.8]
Sens BTUH [kW] 22.8 [6.68] 21.8 [6.39] 20.3 [5.95] 27.7 [8.12] 26.5 [7.77] 24.6 [7.21] 28.7 [8.41] 27.4 [8.03] 25.5 [7.47]
Power
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
Total BTUH [kW] 38.6 [11.31] 37.9 [11.11] 36.9 [10.81] 35.5 [10.40] 34.9 [10.23] 33.9 [9.94] 33.8 [9.91] 33.2 [9.73] 32.3 [9.47]
105
[40.6]
Sens BTUH [kW] 22.1 [6.48] 21.1 [6.18] 19.6 [5.74] 26.9 [7.88] 25.7 [7.53] 23.9 [7.00] 27.9 [8.18] 26.6 [7.80] 24.8 [7.27]
Power
3.0
3.0
2.9
3.0
2.9
2.9
3.0
2.9
2.9
U
R
E
Total BTUH [kW] 36.9 [10.81] 36.2 [10.61] 35.2 [10.32] 33.8 [9.91] 33.1 [9.70] 32.2 [9.44] 32.0 [9.38] 31.4 [9.20] 30.6 [8.97]
110
[43.3]
Sens BTUH [kW] 21.1 [6.18] 20.1 [5.89] 18.7 [5.48] 26.0 [7.62] 24.8 [7.27] 23.1 [6.77] 26.9 [7.88] 25.7 [7.53] 23.9 [7.00]
°F
[°C]
Power
3.1
3.1
3.1
3.1
3.1
3.0
3.1
3.1
3.0
Total BTUH [kW] 34.6 [10.14] 34.0 [9.96] 33.1 [9.70] 31.5 [9.23] 30.9 [9.06] 30.1 [8.82] 29.7 [8.70] 29.2 [8.56] 28.4 [8.32]
115
[46.1]
Sens BTUH [kW] 19.9 [5.83] 19.0 [5.57] 17.7 [5.19] 24.8 [7.27] 23.7 [6.95] 22.0 [6.45] 25.7 [7.53] 24.6 [7.21] 22.9 [6.71]
Power
3.3
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
GROSS SYSTEMS PERFORMANCE DATA—RSNA-B042
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE
CFM [L/s]
DR ➀
71°F [21.7°C]
1350 [637]
.23
67°F [19.4°C]
1350 [637]
.23
63°F [17.2°C]
1350 [637]
.23
1490 [703]
.24
1150 [543]
.21
1490 [703]
.24
1150 [543]
.21
1490 [703]
.24
1150 [543]
.21
Total BTUH [kW] 51.1 [14.98] 50.2 [14.71] 48.8 [14.30] 47.7 [13.98] 46.9 [13.75] 45.6 [13.36] 45.2 [13.25] 44.3 [12.98] 43.1 [12.63]
75
[23.9]
Sens BTUH [kW] 28.1 [8.24] 26.9 [7.88] 25.0 [7.33] 33.4 [9.79] 31.9 [9.35] 29.7 [8.70] 37.9 [11.11] 36.2 [10.61] 33.6 [9.85]
Power
2.6
2.6
2.5
2.5
2.5
2.5
2.5
2.5
2.5
O
U
T
D
O
O
R
Total BTUH [kW] 50.1 [14.68] 49.2 [14.42] 47.8 [14.01] 46.7 [13.69] 45.9 [13.45] 44.6 [13.07] 44.1 [12.92] 43.3 [12.69] 42.2 [12.37]
80
Sens BTUH [kW] 27.9 [8.18] 26.7 [7.83] 24.8 [7.27] 33.2 [9.73] 31.7 [9.29] 29.5 [8.65] 37.6 [11.02] 36.0 [10.55] 33.5 [9.82]
[26.7]
Power
2.7
2.7
2.7
2.7
2.7
2.6
2.7
2.7
2.6
Total BTUH [kW] 49.0 [14.36] 48.1 [14.10] 46.8 [13.72] 45.6 [13.36] 44.8 [13.13] 43.6 [12.78] 43.1 [12.63] 42.3 [12.40] 41.1 [12.05]
85
[29.4]
Sens BTUH [kW] 27.5 [8.06] 26.3 [7.71] 24.5 [7.18] 32.8 [9.61] 31.3 [9.17] 29.1 [8.53] 37.2 [10.90] 35.6 [10.43] 33.1 [9.70]
Power
2.9
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
D
R
Y
Total BTUH [kW] 47.9 [14.04] 47.0 [13.77] 45.8 [13.42] 44.5 [13.04] 43.7 [12.81] 42.5 [12.46] 42.0 [12.31] 41.2 [12.07] 40.1 [11.75]
90
[32.2]
Sens BTUH [kW] 27.0 [7.91] 25.8 [7.56] 24.0 [7.03] 32.2 [9.44] 30.8 [9.03] 28.6 [8.38] 36.7 [10.76] 35.0 [10.26] 32.6 [9.55]
B
U
L
Power
3.0
3.0
2.9
3.0
3.0
2.9
3.0
2.9
2.9
Total BTUH [kW] 46.8 [13.72] 45.9 [13.45] 44.7 [13.10] 43.4 [12.72] 42.6 [12.48] 41.4 [12.13] 40.8 [11.96] 40.1 [11.75] 39.0 [11.43]
95
[35]
B
Sens BTUH [kW] 26.3 [7.71] 25.1 [7.36] 23.4 [6.86] 31.5 [9.23] 30.1 [8.82] 28.0 [8.21] 36.0 [10.55] 34.4 [10.08] 32.0 [9.38]
Power
3.2
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.0
T
E
M
P
E
R
A
T
Total BTUH [kW] 45.6 [13.36] 44.8 [13.13] 43.6 [12.78] 42.2 [12.37] 41.5 [12.16] 40.4 [11.84] 39.7 [11.63] 39.0 [11.43] 37.9 [11.11]
100
[37.8]
Sens BTUH [kW] 25.6 [7.50] 24.4 [7.15] 22.7 [6.65] 30.8 [9.03] 29.4 [8.62] 27.4 [8.03] 35.3 [10.35] 33.7 [9.88] 31.3 [9.17]
Power
3.3
3.3
3.2
3.3
3.2
3.2
3.3
3.2
3.2
Total BTUH [kW] 44.5 [13.04] 43.7 [12.81] 42.5 [12.46] 41.1 [12.05] 40.4 [11.84] 39.3 [11.52] 38.6 [11.31] 37.9 [11.11] 36.8 [10.79]
105
[40.6]
Sens BTUH [kW] 24.8 [7.27] 23.7 [6.95] 22.1 [6.48] 30.1 [8.82] 28.7 [8.41] 26.7 [7.83] 34.5 [10.11] 33.0 [9.67] 30.7 [9.00]
Power
3.4
3.4
3.4
3.4
3.4
3.3
3.4
3.4
3.3
U
R
E
Total BTUH [kW] 43.4 [12.72] 42.6 [12.48] 41.5 [12.16] 40.0 [11.72] 39.3 [11.52] 38.2 [11.20] 37.5 [10.99] 36.8 [10.79] 35.8 [10.49]
110
[43.3]
Sens BTUH [kW] 24.2 [7.09] 23.1 [6.77] 21.5 [6.30] 29.4 [8.62] 28.1 [8.24] 26.1 [7.65] 33.9 [9.94] 32.4 [9.50] 30.1 [8.82]
°F
[°C]
Power
3.6
3.6
3.5
3.6
3.5
3.5
3.5
3.5
3.5
Total BTUH [kW] 42.3 [12.40] 41.6 [12.19] 40.4 [11.84] 39.0 [11.43] 38.3 [11.22] 37.2 [10.90] 36.4 [10.67] 35.7 [10.46] 34.8 [10.20]
115
[46.1]
Sens BTUH [kW] 23.6 [6.92] 22.5 [6.59] 21.0 [6.15] 28.8 [8.44] 27.5 [8.06] 25.6 [7.50] 33.3 [9.76] 31.8 [9.32] 29.6 [8.67]
Power
3.7
3.7
3.7
3.7
3.7
3.6
3.7
3.7
3.6
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
[
] Designates Metric Conversions
12
SYSTEMS PERFORMANCE—RSNA-B SERIES
GROSS SYSTEMS PERFORMANCE DATA—RSNA-B048
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE
CFM [L/s]
DR ➀
71°F [21.7°C]
1600 [755]
.19
67°F [19.4°C]
1600 [755]
.19
63°F [17.2°C]
1600 [755]
.19
1760 [831]
.20
1360 [642]
.17
1760 [831]
.20
1360 [642]
.17
1760 [831]
.20
1360 [642]
.17
Total BTUH [kW] 60.8 [17.82] 59.7 [17.50] 58.1 [17.03] 56.4 [16.53] 55.4 [16.24] 53.9 [15.80] 53.1 [15.56] 52.2 [15.30] 50.8 [14.89]
75
[23.9]
Sens BTUH [kW] 36.3 [10.64] 34.7 [10.17] 32.3 [9.47] 41.5 [12.16] 39.7 [11.63] 36.9 [10.81] 48.2 [14.13] 46.0 [13.48] 42.8 [12.54]
Power
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.8
2.8
O
U
T
D
O
O
R
Total BTUH [kW] 59.9 [17.55] 58.8 [17.23] 57.2 [16.76] 55.5 [16.27] 54.5 [15.97] 53.0 [15.53] 52.3 [15.33] 51.3 [15.03] 49.9 [14.62]
80
Sens BTUH [kW] 35.2 [10.32] 33.7 [9.88] 31.3 [9.17] 40.4 [11.84] 38.6 [11.31] 35.9 [10.52] 47.1 [13.80] 45.0 [13.19] 41.8 [12.25]
[26.7]
Power
3.1
3.1
3.0
3.1
3.1
3.0
3.0
3.0
3.0
Total BTUH [kW] 58.8 [17.23] 57.7 [16.91] 56.1 [16.44] 54.4 [15.94] 53.4 [15.65] 51.9 [15.21] 51.1 [14.98] 50.2 [14.71] 48.8 [14.30]
85
[29.4]
Sens BTUH [kW] 34.3 [10.05] 32.8 [9.61] 30.5 [8.94] 39.5 [11.58] 37.7 [11.05] 35.1 [10.29] 46.1 [13.51] 44.1 [12.92] 41.0 [12.02]
Power
3.3
3.2
3.2
3.3
3.2
3.2
3.2
3.2
3.1
D
R
Y
Total BTUH [kW] 57.4 [16.82] 56.4 [16.53] 54.8 [16.06] 53.0 [15.53] 52.0 [15.24] 50.6 [14.83] 49.7 [14.57] 48.8 [14.30] 47.5 [13.92]
90
[32.2]
Sens BTUH [kW] 33.5 [9.82] 32.0 [9.38] 29.8 [8.73] 38.7 [11.34] 37.0 [10.84] 34.4 [10.08] 45.3 [13.28] 43.4 [12.72] 40.3 [11.81]
B
U
L
Power
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.3
3.3
Total BTUH [kW] 55.9 [16.38] 54.9 [16.09] 53.4 [15.65] 51.5 [15.09] 50.6 [14.83] 49.2 [14.42] 48.2 [14.13] 47.4 [13.89] 46.1 [13.51]
95
[35]
B
Sens BTUH [kW] 33.1 [9.70] 31.6 [9.26] 29.4 [8.62] 38.3 [11.22] 36.6 [10.73] 34.0 [9.96] 45.0 [13.19] 42.9 [12.57] 39.9 [11.69]
Power
3.6
3.6
3.5
3.6
3.6
3.5
3.5
3.5
3.5
T
E
M
P
E
R
A
T
Total BTUH [kW] 54.3 [15.91] 53.3 [15.62] 51.9 [15.21] 49.9 [14.62] 49.0 [14.36] 47.7 [13.98] 46.7 [13.69] 45.8 [13.42] 44.6 [13.07]
100
[37.8]
Sens BTUH [kW] 33.0 [9.67] 31.5 [9.23] 29.3 [8.59] 38.2 [11.20] 36.5 [10.70] 34.0 [9.96] 45.0 [13.19] 42.9 [12.57] 39.9 [11.69]
Power
3.8
3.7
3.7
3.8
3.7
3.7
3.7
3.7
3.6
Total BTUH [kW] 52.8 [15.47] 51.8 [15.18] 50.4 [14.77] 48.4 [14.18] 47.5 [13.92] 46.2 [13.54] 45.1 [13.22] 44.3 [12.98] 43.1 [12.63]
105
[40.6]
Sens BTUH [kW] 33.4 [9.79] 31.9 [9.35] 29.7 [8.70] 38.6 [11.31] 36.9 [10.81] 34.3 [10.05] 45.1 [13.22] 43.2 [12.66] 40.2 [11.78]
Power
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.8
U
R
E
Total BTUH [kW] 51.3 [15.03] 50.4 [14.77] 49.0 [14.36] 46.9 [13.75] 46.1 [13.51] 44.8 [13.13] 43.6 [12.78] 42.9 [12.57] 41.7 [12.22]
110
[43.3]
Sens BTUH [kW] 34.4 [10.08] 32.9 [9.64] 30.6 [8.97] 39.6 [11.61] 37.8 [11.08] 35.2 [10.32] 43.6 [12.78] 42.9 [12.57] 41.1 [12.05]
°F
[°C]
Power
4.1
4.1
4.0
4.1
4.1
4.0
4.1
4.0
4.0
Total BTUH [kW] 50.0 [14.65] 49.1 [14.39] 47.8 [14.01] 45.6 [13.36] 44.8 [13.13] 43.6 [12.78] 42.3 [12.40] 41.6 [12.19] 40.4 [11.84]
115
[46.1]
Sens BTUH [kW] 36.0 [10.55] 34.4 [10.08] 32.0 [9.38] 41.2 [12.07] 39.4 [11.55] 36.6 [10.73] 42.3 [12.40] 41.6 [12.19] 40.4 [11.84]
Power
4.3
4.2
4.2
4.3
4.3
4.2
4.2
4.2
4.1
GROSS SYSTEMS PERFORMANCE DATA—RSNA-B060
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀
wbE
CFM [L/s]
DR ➀
71°F [21.7°C]
1850 [873]
.20
67°F [19.4°C]
1850 [873]
.20
63°F [17.2°C]
1850 [873]
.20
2040 [963]
.21
1570 [741]
.18
2040 [963]
.21
1570 [741]
.18
2040 [963]
.21
1570 [741]
.18
Total BTUH [kW] 69.9 [20.49] 68.7 [20.13] 66.8 [19.58] 66.3 [19.43] 65.1 [19.08] 63.3 [18.55] 63.8 [18.70] 62.6 [18.35] 60.9 [17.85]
75
[23.9]
Sens BTUH [kW] 41.5 [12.16] 39.7 [11.63] 36.9 [10.81] 48.8 [14.30] 46.7 [13.69] 43.4 [12.72] 53.0 [15.53] 50.6 [14.83] 47.1 [13.80]
Power
3.9
3.8
3.8
3.8
3.7
3.7
3.7
3.7
3.7
O
U
T
D
O
O
R
Total BTUH [kW] 69.6 [20.40] 68.4 [20.05] 66.5 [19.49] 65.9 [19.31] 64.8 [18.99] 63.0 [18.46] 63.4 [18.58] 62.3 [18.26] 60.6 [17.76]
80
Sens BTUH [kW] 40.4 [11.84] 38.6 [11.31] 35.9 [10.52] 47.8 [14.01] 45.6 [13.36] 42.4 [12.43] 51.9 [15.21] 49.6 [14.54] 46.1 [13.51]
[26.7]
Power
4.1
4.0
4.0
4.0
4.0
3.9
3.9
3.9
3.9
Total BTUH [kW] 68.5 [20.08] 67.3 [19.72] 65.4 [19.17] 64.8 [18.99] 63.7 [18.67] 61.9 [18.14] 62.3 [18.26] 61.2 [17.94] 59.5 [17.44]
85
[29.4]
Sens BTUH [kW] 39.4 [11.55] 37.6 [11.02] 35.0 [10.26] 46.7 [13.69] 44.6 [13.07] 41.5 [12.16] 50.9 [14.92] 48.6 [14.24] 45.2 [13.25]
Power
4.3
4.3
4.2
4.2
4.2
4.1
4.2
4.1
4.1
D
R
Y
Total BTUH [kW] 66.8 [19.58] 65.6 [19.23] 63.9 [18.73] 63.2 [18.52] 62.0 [18.17] 60.4 [17.70] 60.7 [17.79] 59.6 [17.47] 58.0 [17.00]
90
[32.2]
Sens BTUH [kW] 38.3 [11.22] 36.6 [10.73] 34.0 [9.96] 45.7 [13.39] 43.6 [12.78] 40.6 [11.90] 49.8 [14.59] 47.6 [13.95] 44.3 [12.98]
B
U
L
Power
4.5
4.5
4.4
4.4
4.4
4.3
4.4
4.3
4.3
Total BTUH [kW] 64.8 [18.99] 63.7 [18.67] 61.9 [18.14] 61.2 [17.94] 60.1 [17.61] 58.4 [17.12] 58.7 [17.20] 57.6 [16.88] 56.0 [16.41]
95
[35]
B
Sens BTUH [kW] 37.3 [10.93] 35.6 [10.43] 33.1 [9.70] 44.6 [13.07] 42.6 [12.48] 39.7 [11.63] 48.8 [14.30] 46.6 [13.66] 43.4 [12.72]
Power
4.7
4.7
4.6
4.6
4.6
4.5
4.6
4.5
4.5
T
E
M
P
E
R
A
T
Total BTUH [kW] 62.7 [18.38] 61.6 [18.05] 59.9 [17.55] 59.0 [17.29] 58.0 [17.00] 56.4 [16.53] 56.5 [16.56] 55.5 [16.27] 54.0 [15.83]
100
[37.8]
Sens BTUH [kW] 36.3 [10.64] 34.7 [10.17] 32.3 [9.47] 43.6 [12.78] 41.7 [12.22] 38.8 [11.37] 47.8 [14.01] 45.7 [13.39] 42.5 [12.46]
Power
4.9
4.9
4.8
4.8
4.8
4.7
4.8
4.8
4.7
Total BTUH [kW] 60.6 [17.76] 59.6 [17.47] 57.9 [16.97] 57.0 [16.71] 55.9 [16.38] 54.4 [15.94] 54.5 [15.97] 53.5 [15.68] 52.0 [15.24]
105
[40.6]
Sens BTUH [kW] 35.3 [10.35] 33.8 [9.91] 31.4 [9.20] 42.7 [12.51] 40.8 [11.96] 37.9 [11.11] 46.9 [13.75] 44.8 [13.13] 41.6 [12.19]
Power
5.1
5.1
5.0
5.1
5.0
4.9
5.0
5.0
4.9
U
R
E
Total BTUH [kW] 58.8 [17.23] 57.8 [16.94] 56.2 [16.47] 55.2 [16.18] 54.2 [15.88] 52.7 [15.44] 52.7 [15.44] 51.7 [15.15] 50.3 [14.74]
110
[43.3]
Sens BTUH [kW] 34.4 [10.08] 32.9 [9.64] 30.6 [8.97] 41.8 [12.25] 39.9 [11.69] 37.1 [10.87] 45.9 [13.45] 43.9 [12.87] 40.8 [11.96]
°F
[°C]
Power
5.3
5.3
5.2
5.3
5.2
5.2
5.2
5.2
5.1
Total BTUH [kW] 57.5 [16.85] 56.5 [16.56] 55.0 [16.12] 53.9 [15.80] 52.9 [15.50] 51.4 [15.06] 51.3 [15.03] 50.4 [14.77] 49.0 [14.36]
115
[46.1]
Sens BTUH [kW] 33.5 [9.82] 32.0 [9.38] 29.8 [8.73] 40.9 [11.99] 39.1 [11.46] 36.3 [10.64] 45.0 [13.19] 43.0 [12.60] 40.0 [11.72]
Power
5.6
5.5
5.4
5.5
5.4
5.4
5.4
5.4
5.3
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
[
] Designates Metric Conversions
13
AIRFLOW PERFORMANCE—RSNA-B SERIES
14
AIRFLOW PERFORMANCE—RSNA-B SERIES
15
ELECTRICAL DATA—RSNA-B SERIES
ELECTRICAL DATA – RSNA-B SERIES
-B024JK
-B030JK
-B036CK
-B036JK
-B042CK
-B042JK
-B048CK
-B048JK
-B060CK
-B060JK
Unit Operating
Voltage Range
187-253
187-253
187-253
187-253
187-253
187-253
187-253
187-253
187-253
187-253
Minimum Circuit Ampacity
16/16
20/20
25/25
22/22
25/25
35/35
16/16
20/20
25/25
22/22
30/30
35/35
18/18
20/20
25/25
26/26
30/30
40/40
22/22
25/25
30/30
32/32
40/40
50/50
33/33
40/40
50/50
43/43
50/50
60/60
Minimum Overcurrent
Protection Device Size
Maximum Overcurrent
Protection Device Size
No.
1
208/230
1
1
208/230
1
1
208/230
3
1
208/230
1
1
208/230
3
1
208/230
1
1
208/230
3
1
208/230
1
1
208/230
3
1
Volts
208/230
Phase
1
HP
2 1/6
3450
2 2/3
3450
3 1/3
3450
9.6/9.6
88/88
1
3 1/3
3450
3 1/2
3450
3 1/2
3450
4
4
5
5
RPM
3450
3450
3450
3450
Amps (RLA)
10.4/10.4 14.1/14.1
14.4/14.4 10.3/10.3 16.5/16.5 12.2/12.2 20.2/20.2 17.3/17.3
25/25
Amps (LRA)
54/54
68/68
77/77
77/77
95/95
80.8/80.8
137/137
123/123
148/148
No.
1
208/230
1
1
208/230
1
1
208/230
1
1
1
1
1
1
1
Volts
208/230
1
208/230
208/230
208/230
208/230
208/230
208/230
Phase
1
1/3
2
1
1/3
2
1
1/3
2
1
1/3
2
1
1
HP
1/5
1/5
1/5
1/5
1/3
1/3
Amps (FLA)
1.3
1.3
1.3
1.3
2
2
Amps (LRA)
2.3
2.3
2.3
2.3
3.9
1
3.9
1
3.9
1
3.9
1
3.9
3.9
No.
1
1
1
1
1
1
Volts
208/230
1
208/230
1
208/230
1
208/230
1
208/230
1
208/230
1
208/230
1
208/230
1
208/230
208/230
Phase
HP
1
1
1
1
1/4
1/2
1/2
1/2
1/2
2.4
5.1
1/2
2.4
5.1
3/4
4.4
9.5
3/4
4.4
9.5
Amps (FLA)
Amps (LRA)
1.3
2.3
2.4
5.1
2.4
5.1
2.4
5.1
9.1
0
9.1
0
1. Horsepower Per Compressor.
2. Amp Draw Per Motor. Multiply Value By Number of Motors to Determine Total Amps.
Copper Wire Size—AWG (1% Voltage Drop)
300
250
200
150
4
4
6
8
3
4
4
6
8
2
3
4
6
8
2
3
4
4
6
1
2
3
4
6
8
1/0 1/0 2/0 2/0 3/0 3/0 3/0 4/0 4/0 4/0
4/0
4/0
3/0
1/0
1
250 250 250 250 300 300 300
1
2
4
6
8
1
2
3
4
6
1/0 1/0 2/0 2/0 2/0 3/0 3/0 3/0
4/0
3/0
2/0
1
4/0
3/0
2/0
1
4/0
3/0
2/0
1
4/0
3/0
2/0
1/0
2
250 250 250
1
3
4
6
1
2
4
6
1/0 1/0 1/0 2/0 2/0 2/0
4/0
2/0
1/0
1
4/0
3/0
1/0
1
4/0
3/0
1/0
1
2
3
4
1
3
4
1
2
4
1/0 1/0 1/0
100 10
2
3
2
3
1
3
50 14 12 10 10
2
2
2
2
15 20 25 30 35
40
45
50
55
60
65
70
75
80
85
90
95
100 105 110 115 120 125
CIRCUIT AMPACITY
Notes: 1. Wire size based on 60°C. type copper conductors below 100 ampacity.
2. Wire size based on 75°C. type copper conductors for 100 ampacity and above.
[
] Designates Metric Conversions
16
ELECTRIC HEATER KITS—RSNA-B SERIES
17
UNIT DIMENSIONS—RSNA-B SERIES
UNIT DIMENSIONS
PACKAGE
AIR CONDITIONERS
OUTDOOR FAN GRILLE
AND COMPRESSOR ACCESS
CONTROL
FILTER ACCESS
ACCESS PANEL
PANEL (FOR
UNIT MOUNTED
FILTER ACCESSORY)
30% 2%
LIQUID PRESSURE
SERVICE PORT
OUTDOOR COIL
PROTECTIVE GRILLE
TOP COVER
21% 2%
SUCTION PRESSURE
SERVICE PORT
THREADED PVC CONDENSATE
DRAIN CONNECTION N.P.T.
THERMOSTAT WIRING
ENTRANCE
29% 2%
IMPORTANT: UNIT MUST BE LEVEL TO
PREVENT WATER MIGRATION
ELECTRICAL POWER
ENTRANCE
CORNER WEIGHTS
% OF TOTAL
UNIT WEIGHT
20% 2%
SIDE RETURN
DUCT OPENING
BLOWER/
EVAPORATOR
ACCESS PANEL
SIDE SUPPLY
DUCT OPENING
TOP VIEW
BOTTOM VIEW
451/16"
4719/32"
[1209 mm]
[1145 mm]
13/16"
[30 mm]
TYP.
INSIDE
11/2"
[38 mm]
TYP.
BOTTOM
RETURN
DUCT
OPENING
5013/16"
[1290 mm]
497/16"
[1256 mm]
INSIDE
BOTTOM
SUPPLY
DUCT
141/4"
[362 mm]
TYP.
OPENING
199/16"
[497 mm]
153/8"
[391 mm]
313/16"
[97 mm]
45/16"
[95 mm]
33/16"
[97 mm]
OUTDOOR FAN
GRILLE &
COMPRESSOR ACCESS
[
] Designates Metric Conversions
18
UNIT DIMENSIONS—RSNA-B SERIES
SIDE VIEW
SIDE VIEW
OUTDOOR
COIL PROTECTIVE
GRILLE
FILTER ACCESS PANEL (FOR UNIT
MOUNTED FILTER ACCESSORY
THERMOSTAT
WIRE ENTRANCE
11/8"
[28.6 mm]
255/16"
[643 mm]
103/16"
[259 mm]
51/16"
[129 mm]
ELECTRICAL
POWER ENTRANCE
527/16"
[1332 mm]
BLOWER/
EVAPORATOR
ACCESS PANEL
43/4"
[121 mm]
FRONT VIEW
REAR VIEW
CONTROL
ACCESS PANEL
47/8"
[124 mm]
SIDE SUPPLY
DUCT OPENING
133/4"
[349 mm]
LIQUID
PRESSURE
SERVICE PORT
75/16"
[186 mm]
57/16" [138 mm]
81/2"
[216 mm]
TYP.
143/16"
[360 mm]
TYP.
2211/16"
[576 mm]
47/16"
[113 mm]
471/2"
[1207 mm]
15"
[381 mm]
191/8"
[486 mm]
SIDE RETURN
DUCT OPENING
SHOWN WITH DUCT COVERS REMOVED.
THREADED PVC
CONDENSATED DRAIN
CONNECTION (3/4 N.P.T.)
SUCTION PRESSURE
SERVICE PORT
IMPORTANT:
IMPORTANT:
Unit must be level to
prevent water migration.
INSTALLATION MUST NOT
INTERFERE WITH DRAINAGE
OPENINGS IN BOTTOM OF UNIT
UNDER OUTDOOR COIL.
Model #
Height “A”
B024, B030,
B036
3515/16
B042, B048,
B060
41
19
TYPICAL INSTALLATIONS
20
ACCESSORIES
ACCESSORY EQUIPMENT
Accessory
Model
Application
Accessory
Model No.
Description
RXSG-AAA08 (8" [203 mm] Height)
RXSG-AAA14 (14" [356 mm] Height)
RXSG-AAA24 (24" [610 mm] Height)
Roofcurbs
RSNA-B
Supply & Return Diffusers
RSNA-B
RSNA-B
RXRN-BD15
RXRE-CAA30 (3 Position)
RXRD-CAM10 (Fully Modulating)
Economizers (Downflow ONLY)
RXRF-FAB1 (Motorized-35%)
RXRF-FAA1 (Fixed-35%)
Fresh Air Damper
RSNA-B
RSNA-B
RXMC-CA02 (16" [406 mm] Ducts)
RXMC-CA03 (18" [457 mm] Ducts)
Rectangular to Round Transition (Downflow)
Filter Kit
RSNA-B
RSNA-B
RSNA-B
RSNA-B
RSNA-B
RXRY-B01
RXRZ-A18
RXAB-A02
RXAC-A02
RXMC-BA01
Low Ambient Control
High Pressure Control
Low Pressure Control
Sideflow Rectangular to Round Transition
RXGJ-EP84W (White-Rodgers Gas Valve)
RXGJ-EP85H (Honeywell Gas Valve)
LP Conversion Kits
RSNA-B
RSNA-B
Canadian High Altitude Kit (for Natural Gas only*)
RXRX-AH01
*If a particular unit is to be converted to operate on LP (propane) for elevations above 2000 ft. [609.6 m] in Canada, the existing Natural Gas to LP Conversion Kits for the
subject models already contain the necessary orifices and instructions to de-rate the input for 2000-4500 ft. [609.6-1371.6 m] Canadian applications.
[
] Designates Metric Conversions
COMMON SUPPLY/RETURN
CONCENTRIC AIR DIFFUSER
SUPPLY/RETURN DIFFUSER
NOTE: The location of the combination supply and return diffuser should
not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM
[472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level
for units with CFM greater than 1000 [472 L/s]. If the diffuser is installed
with a greater distance than recommended above, the supply air may
become stratified above the required comfort area causing uncomforta-
ble conditions.
AIRFLOW/PRESSURE DROP
INFORMATION (INCHES W.C. [kPa])
Designed to convert a side by side or an over and under arrange-
ment into a concentric distribution of air. The diffuser is flush
mounted, completely insulated, assembled, and internally baffled
to provide four way supply air distribution with a center return. To
make the assembly complete and ready to fit into a 2' [0.61 m] x
4' [1.22 m] suspended ceiling grid, the diffuser includes
adjustable supply louvers, hanging rings, anti-sweat gasket, and
round flanges for use with flexible ducts.
Approximate CFM [L/s]-Supply Air
Accessory
1300 [614] 1575 [743] 1800 [850] 2200 [1038]
Plenum & Supply/Return Duct .07 [.017] .10 [.024] .12 [.030] .17 [.042]
Diffuser
Economizer
.09 [.022] .13 [.032] .16 [.040] .24 [.060]
.06 [.015] .09 [.022] .11 [.027] .17 [.042]
SUPPLY AIR/PERFORMANCE
Diffuser Airflow CFM [L/s]
800 [378]-1200 [566]
1600 [755]-2000 [944]
Range of Throw Ft. [m]
14 [4.27]-16 [4.88]
18 [5.49]-28 [8.53]
Model No.
RXRN-
Diameter
Inches [mm]
Shipping Wt.
Lbs. [kg]
Dimension A
Inches [mm]
BD15
16 [406]
90 [40.82]
201/2 [521]
21
ACCESSORIES
DUCT ADAPTERS
RECTANGULARTO ROUND
TRANSITIONS (DOWNFLOW)
RXMC-CA02
RXMC-CA03
[
] Designates Metric Conversions
22
ACCESSORIES
FRESH AIR DAMPER FOR USE ON
RSNA-B SERIES
RXRF-FAA1 (Fixed - 0-35%)
The 0-35% manual outside Air Damper is designed to replace the
unit return air duct cover. No drilling or damper assembly is
required. The amount of outside air (0-35%) is controlled by sim-
ply adjusting the side damper.
RXRF-FAB1 (Motorized - 0-35%)
The 0-35% motorized outside Air Damper is designed to replace
the unit return air duct cover. No drilling or damper assembly is
required. The control motor opens the adjustable slide damper
when the unit blower motor is energized.
ECONOMIZERS
RXRE-CAA30 (3 Position) and
RXRD-CAM10 (Fully Modulating) for
RSNA-B Series
RXRE-CAA30 (3 Position)
Provided with enthalpy control, and
mixed air sensor. Settings include
fully open, fully closed and adjustable
mid point.
RXRD-CAM10 (Fully Modulating)
Provided with enthalpy control, mixed
air sensor and minimum position poten-
tiometer for proportioning (modulating)
the amount of fresh air.
Note: See economizer installation instruc-
tions for correct filter access door.
[
] Designates Metric Conversions
23
ACCESSORIES
FILTER KIT INSTALLATION
RXRY-B01
For use in either
vertical or horizontal
discharge.
CFM [L/s]
Airflow Pressure Drop, Inches W.C. [kPa]
1" Filter
Minimum
Airflow
Nominal
Airflow
Maximum
Airflow
CFM [L/s]
500 [236]
600 [283]
700 [330]
800 [378]
900 [425]
1000 [472]
1100 [519]
1200 [566]
1300 [614]
1400 [661]
1500 [708]
1600 [755]
1700 [802]
1800 [850]
1900 [897]
2000 [944]
2" Filter
Model No.
.02 [.0050]
.03 [.0075]
.03 [.0075]
.04 [.0010]
.05 [.0124]
.06 [.0149]
.08 [.0199]
.09 [.0224]
.12 [.0299]
.15 [.0373]
.19 [.0473]
.21 [.0523]
.23 [.0572]
.24 [.0598]
.25 [.0623]
.27 [.0672]
.29 [.0722]
RSNA-B
RSNA-B
RSNA-B
RSNA-B
RSNA-B
RSNA-B
510 [241]
680 [321]
850 [401]
1020 [481]
1190 [562]
1275 [602]
600 [283]
800 [378]
660 [311]
880 [415]
.02 [.0050]
.03 [.0075]
1000 [472]
1200 [566]
1400 [661]
1500 [708]
1100 [519]
1320 [623]
1540 [727]
1650 [779]
.04 [.0010]
.05 [.0124]
.07 [.0174]
.08 [.0199]
.10 [.0249]
.13 [.0324]
[
] Designates Metric Conversions
.16 [.0398]
.19 [.0473]
.20 [.0498]
.21 [.0523]
.22 [.0548]
.24 [.0598]
.26 [.0647]
24
ACCESSORIES
DUCT ADAPTER SIDEFLOW
SQUARETO ROUNDTRANSITION
RXMC-BA01
Adapts the side rectangular supply and return openings to 14"
[356 mm] diameter round openings. Adapters provided with same
finish as unit and also provided with thermal insulation.
25
ACCESSORIES
ROOFCURB (Full Perimeter)
RXSG-AAA08, RXSG-AAA14
and RXSG-AAA24 for
RSNA-B Series
Hinged corners make for
fast, easy set-up.
RXSG-AAA08
(8" [203 mm] High)
NOT for use with
RQKA/RQLA/RQMA
Package Heat Pumps.
[
] Designates Metric Conversions
26
ACCESSORIES
ROOFCURB (Full Perimeter) (Cont.)
RXSG-AAA24
(24" [610 mm] High)
[
] Designates Metric Conversions
27
ACCESSORIES
PACKAGE AIR CONDITIONERS &
GAS/ELECTRIC PACKAGE UNITS
ROOFCURB INSTALLATION (Full Perimeter)
[
] Designates Metric Conversions
ROOFCURB ADAPTERS
Fabricated from galvanized steel to adapt the New cabinet to the old style curb. All are furnished with a New gasket.
OLD MODEL
OLD CURB MODEL
NEW MODEL TO OLD MODEL
ROOFCURB ADAPTER
NEW MODEL PACKAGE
SMALL CABINET
RXPA-CA20 (1)
RXRA-DB20 (2)
(11/2-2 TON) [5.28-7.03 kW]
RSNC-, RSND-, RSNE-
RRGE-, RRGF-, RRGG-, RSNY
20 SERIES
ONLY 1 CABINET SIZE—
MEDIUM CABINET
ALL MODELS
RXPA-CA21 (1)
RXRA-DB21 (2)
RXPX-BACCA20
RXRX-BACDB20
RXPX-BACCA21
RXRX-BACDB21
RXPX-BCCCA22
RXRX-BCCDB22
RXPX-BCCCA23
RXRX-BCCDB23
(21/2-3 TON) [8.79-10.55 kW]
RSNC-, RSND-, RSNE-
RRGE-, RRGF-, RRGG-, RSNY
21 SERIES
22 SERIES
RSNA-B
LARGE CABINET
(3-31/2 TON) [10.55-12.31 kW]
RRGE-, RRGF-, RRGG-, RSNY
RXPA-CA22 (1)
RXRA-DB22 (2)
EXTRA LARGE CABINET
(31/2-5 TON) [12.31-17.58 kW]
RSNC-, RSND-, RSNE-
RXPA-CA23 (1)
RXRA-DB23 (2)
23 SERIES
RRGE-, RRGF-, RRGG-, RSNY
(4-5 TON) [14.07-17.58 kW]
(1) SLOPE TYPE
(2) FULL PERIMETER TYPE
28
ACCESSORIES
LIFT KIT—MODEL NO. RXML-A01
The lift kit is intended for temporary installation while the unit is
being lifted into position. Kit includes 4 lift brackets.
29
ACCESSORIES
ELECTRIC HEATER KITS—RSNA-B
Unit Model Application
Electric Heater Kit Models
RXQJ-A05J (208-240 volt, 1-ph, 5kW)
RXQJ-A10J (208-240 volt, 1-ph, 10kW)
RXQJ-A05J (208-240 volt, 1-ph, 5kW)
RXQJ-A10J (208-240 volt, 1-ph, 10kW)
RXQJ-A10J (208-240 volt, 1-ph, 10kW)
RXQJ-A15J (208-240 volt, 1-ph, 15kW)
RXQJ-B10J (208-240 volt, 1-ph, 10kW)
RXQJ-B15J (208-240 volt, 1-ph, 15kW)
RXQJ-B10J (208-240 volt, 1-ph, 10kW)
RXQJ-B15J (208-240 volt, 1-ph, 15kW)
RXQJ-A10C (208-240 volt, 3-ph, 10kW)
RXQJ-A15C (208-240 volt, 3-ph, 15kW)
RXQJ-A16C (208-240 volt, 3-ph, 15kW-Canadian)
RXQJ-A10C (208-240 volt, 3-ph, 10kW)
RXQJ-A15C (208-240 volt, 3-ph, 15kW)
RXQJ-A10C (208-240 volt, 3-ph, 10kW)
RXQJ-A15C (208-240 volt, 3-ph, 15kW)
RSNA-B024JK
RSNA-B030JK
RSNA-B036JK
RSNA-B042JK
RSNA-B048JK
RSNA-B036CK
RSNA-B042CK
RSNA-B048CK, RSNA-B060CK
[
] Designates Metric Conversions
WARNING
ONLY ELECTRIC HEATER KITS SUPPLIED BY THIS MANUFACTURER AS DESCRIBED IN THIS PUBLICATION HAVE BEEN DESIGNED,
TESTED, AND EVALUATED BY A NATIONALLY RECOGNIZED SAFETYTESTING AGENCY FOR USEWITHTHIS UNIT. USE OF ANY OTHER
MANUFACTURED ELECTRIC HEATERS INSTALLED WITHIN THIS UNIT MAY CAUSE HAZARDOUS CONDITIONS RESULTING IN PROP-
ERTY DAMAGE, FIRE, BODILY INJURY OR DEATH.
30
WIRING SCHEMATICS—RSNA-B SERIES
31
WIRING SCHEMATICS—RSNA-B SERIES
32
WIRING SCHEMATICS—RSNA-B SERIES
33
WIRING SCHEMATICS—RSNA-B SERIES
34
WIRING SCHEMATICS—RSNA-B SERIES
35
WIRING SCHEMATICS—RSNA-B SERIES
36
NOTES
37
NOTES
38
NOTES
39
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM
YOUR RETAILER.
GENERALTERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
periods stated, in accordance with the terms of the limited
warranty.
For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, SeeYour Local Installer or Contact the Manufacturer for
a Copy.
Condenser Coil and Evaporator Coil leaks
caused by factory defects ..........................Five (5) Years
Compressor..................................................Five (5) Years
Any Other Part
1-Phase Models............................................Five (5) Years
3-Phase Models..............................................One (1) Year
RHEEM
AIR CONDITIONING
DIVISION
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
5600 Old Greenwood Road, Fort Smith, Arkansas 72908
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A.
11-05 DC
FORM NO. S11-933 REV. 2
Supersedes Form No. S11-933 Rev. 1
|
Samsung Tipo Ventana Aw0800a User Manual
Precisionaire Swissaire Bag Pb1104 User Manual
Panasonic Kx Fp105 User Manual
MAKITA VR251D User Manual
LG LG C320 User Manual
HITACHI 65X500 User Manual
CRAFTSMAN 320.30856 User Manual
BROTHER HL 5350DN 02 User Manual
BLACK DECKER BDH1850SM User Manual
ASUS RT AC3200 User Manual