Architectural & Engineering Specifications
March 2004
®
Heat-A-Vent
MODEL: 605RP
DESCRIPTION
• Two functions in one unit. Use them individually
or together.
1) 1500W heating element provides fast enveloping
heat. Efficient fan evenly distributes warm air
through room.
2) Exhausts stale air and moisture to refresh the bath
atmosphere.
• Streamline design with handsome white grille. Grille
is tough polymeric, impervious to bathroom climate.
• Includes adjustable hanger bars. 16"-24". Built-in
junction box with receptacles for simple plug-in of heater
and fan motors.
• Nickel-chrome heating element.
• Quiet polypropylene duct adapter with silent backdraft
damper snaps on. Longer tapering collar for easy
attachment of 4" duct.
• Connects to 120vAC.
• For your convenience, NuTone offers a complete line
of accessories to adapt this unit to your construction
requirements.
INSTALLATION
DESIGN FEATURES
• Adjustable hanger bars attach to 16" or 24" O.C. joists
in new construction.
Air Delivery:
Sound Level:
British Thermal
Units:
70 CFM.
4.0 Sones.
5118.
• Built-in junction box accepts plug-in heater motor,
and fan motor.
• Duct adapter has built-in damper and long, tapering collar
for duct attachment.
• Discharge is horizontal through 4" round duct.
• Each unit includes complete Installation Instructions
for both new and existing construction.
• Do not install unit over bath tub or in shower stall.
• Connect to 20 amp branch circuit.
Dimensions:
Housing: 145⁄8" x 77⁄8" x 55⁄8".
Grille: 97⁄8" x 161⁄4".
Material &
Housing: Galvanized steel,
Component Data: Grille: White polymeric.
Damper: polypropylene.
Centrifugal.
Sleeve bearings, thermally protected.
Open coil, nickel-chromium. 1500W.
4" diameter.
Impellers:
Motors:
Element:
Duct Size:
ARCHITECT'S SPECIFICATIONS
Heat-Vent Combination shall be Model 605RP as
manufactured by NuTone according to listed specifications.
Electrical Rating: 120V, 60Hz, 13.5A
NUTONE, INC. / 4820 RED BANK ROAD, CINCINNATI, OHIO 45227
Product specifications subject to change without notice.
REFERENCE
QTY.
REMARKS
Project
Location
Architect
Engineer
Contractor
Submitted by
Date
|