Manual Attic Fan User Manual

INSTALLATION INSTRUCTIONS  
FOR  
WHOLE HOUSE FANS  
Models: CX242DDWT, CX302DDWT, CX24BD2SPD, CX30BD2SPD, CX36BD2SPD  
Read all warnings and instructions before beginning to install this fan.  
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN INJURY OR DEATH  
1. Do not attempt to use this fan with any speed control device.  
2. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.  
3. Before servicing or cleaning this unit, switch power off at the service panel and lock out to prevent power from being  
switched on accidentally. When service disconnecting means cannot be locked, securely fasten a prominent warning tag to  
the service panel.  
4. Installation work and electrical wiring must be performed by a qualified person in accordance with all applicable codes and  
standards, including fire-rated construction.  
5. When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.  
6. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow  
the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire and  
Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air-conditioning Engineers  
(ASHRAE), and the local code authorities.  
CAUTION  
DOUBLE CHECK FAN BLADES ARE SECURE TO HUB PRIOR TO INSTALLATION.  
BLADES CAN BE DAMAGED DURING SHIPMENT AND CAN BECOME A HAZARD  
UPON ACTIVATION OF MOTOR!  
1. This unit has an unguarded propeller. Do not use in locations readily accessible to people or animals.  
2. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.  
3. Carbon monoxide is an odorless, colorless gas that can kill. It may be drawn into the house by operating  
this fan if your fuel-burning equipment is not properly maintained, or if you lack adequate attic space.  
Deciding on a Joist-In or Joist-Out Installation  
Joist-In Installation  
Joist-Out Installation  
The ceiling joists will be left intact for this  
method. You will need another attic access, as the  
fan will not fit through the shutter opening with  
the joist(s) in place.  
This method involves removing one or more  
ceiling joists. This is the preferred method, as the  
best location does not necessarily coincide with  
the position of the joists.  
Step 1: Prepare the Shutter Opening  
Find a spot in the center of the hallway, drill a hole  
and feed a wire through to mark it.  
Mark space around the wire equal to the area of the  
rough shutter opening in the chart below in the joist-  
in or joist-out option below.  
Remove all insulation above the installation site.  
Fan Size  
24-in.  
Shutter Rough Opening (L X W)  
28X 26”  
30-in.  
32 1/4” X 29 1/2”  
34X 37 1/2”  
36-in.  
Joist-In Installation  
Joist-Out Installation  
Align shutter vein with ceiling joist in the  
center of the shutter opening.  
Drill two ¼” holes (from attic floor  
through the ceiling) at the two corners that are  
aligned with one of the ceiling joists.  
On ceiling side, draw a straight line between  
the two drilled holes. Use this line as a guide  
to mark the other three sides of the shutter  
opening, using rough opening dimensions  
chart above.  
Draw a line on the ceiling marking the rough  
opening size of the shutter frame.  
Double-check the accuracy of the dimensions  
you have marked and that all the corners are  
square.  
TIP: Use the shutter as a template to outline the  
opening by drawing the cutout line around the  
inside edges.  
From ceiling side, drill two more ¼” holes at  
the remaining corners.  
Ventamatic, Ltd. | 100 Washington Ave, Mineral Wells, TX 76068 Phone: (800) 433-1626 www.bvc.com  
3
Step 2: Cut the Shutter Opening  
Cut through ceiling along lines using a  
circular saw. Measure depth of drywall  
and adjust the saw so you only cut the  
drywall and avoid the joists.  
Carefully remove the drywall from the  
opening  
*Note* Make sure the exposed joist is  
centered if doing the joist-in installation.  
Step 3: Cut the Ceiling Joist (For Joist-Out Installation Only)  
Stabilize the joists using 2 X 6 lumber to  
bridge the joist about six inches away from  
either side of the opening.  
Attach stabilizers to the joists with #12D nails  
or 2 1/2” deck screws.  
Mark two lines on the joists to be cut about  
1 1/2” away from either side of the opening.  
Cut along the lines using a saber saw. Make  
sure cuts are perpendicular and accurate.  
Step 4: Frame the Shutter Opening  
Use lumber of the same dimensions as your ceiling joists and fasten them to the edges of the frame  
opening using #12D nails.  
Fasten the sheetrock to the new frame using 1 1/2” ring shank drywall nails.  
Seal any gaps between headers and joists with caulk or foam insulation.  
_*Note* Remove the two bridges from the previous step if doing a joist-out installation.______________  
Joist-Out Installation  
Joist-In Installation  
Ventamatic, Ltd. | 100 Washington Ave, Mineral Wells, TX 76068 ▪ Phone: (800) 433-1626 ▪ www.bvc.com  
4
Step 5: Facing Installation  
Use 2 X 6 boards to create a square with the inside dimensions being the same distance as the shortest  
dimension of the shutter rough opening (i.e. 26” for a 24-in model, etc.).  
Nail or screw in the facing to the framed opening.  
Joist-In Installation  
Joist-Out Installation  
TIP: If doing a joist-out installation, use lumber from the support pieces as the long cuts and the removed joists as the  
short cuts.  
TIP: For a quieter fan, build a second box frame the same size as the fan frame and install it between the frame and  
facing. Ensure that there is still a minimum of 36” clearance between the fan blades and attic roof.  
Step 6: Prepare and Install Fan Assembly  
Belt Drive Models  
Direct Drive Models  
Remove hardware and remount the motor on  
the top side of the struts.  
Remove fan blade and wire the motor first.  
Replace and secure the blade so it is about  
half-in and half-out of the hub.  
Position fan belt on the pulleys and adjust it to  
fit snugly with about 1/2” deflection. DO NOT  
OVERTIGHTEN THE BELT!  
Tighten fan blade set screw and make sure the  
hub of the fan blade assembly is facing up  
towards the roof.  
Tighten fan blade set screw before operating  
and make sure the hub of the fan blade  
assembly is facing up towards the roof.  
Ventamatic, Ltd. | 100 Washington Ave, Mineral Wells, TX 76068 Phone: (800) 433-1626 www.bvc.com  
5
Step 6: Prepare and Install Fan Assembly (cont.)  
Push fan assembly through the shutter opening diagonally or through another attic access if doing  
a joist-in installation.  
Place frame on top of facing or additional frame and draw alignment marks around the base of the  
assembly then secure to the facing using screws.  
Step 7: Install the Shutter  
_*Note* Never operate the fan without the  
shutter installed  
Draw alignment marks on the ceiling 7/8”  
from the edges to indicate the outer edges of  
the shutter frame.  
Install the shutter using the white-headed  
wood screws provided with your fan.  
Caulk the seams for an airtight seal.  
Step 8: Wiring Instructions  
*Note* All wiring supplies and installations must meet or exceed the requirements of local electrical  
_and fire codes. Wire to 120 Volt, 60 Hz circuit only, using 14-3 two-conductor wiring with ground.  
Disconnect the power supply or switch off the appropriate circuit breaker.  
Install included switches in a double gang UL listed wiring box, in a wall close to the fan.  
Connect incoming power supply wire (BLK) to the top right terminal of the On/Off switch (1).  
Connect bottom right terminal of the On/Off switch (2) to the bottom right terminal of the High/Low  
switch (3) using a jumper wire.  
Ventamatic, Ltd. | 100 Washington Ave, Mineral Wells, TX 76068 ▪ Phone: (800) 433-1626 ▪ www.bvc.com  
6
Step 8: Wiring Instructions (cont.)  
Connect High speed motor lead (BLACK) to the top right terminal of High/Low switch (HIGH).  
Connect Low speed motor lead (RED) to the bottom left terminal of High/Low switch (LOW).  
Connect incoming common wire (WHT) to the common wire (WHITE) from the motor.  
Connect incoming ground wire (GND) to the grounding screw on each switch (4, 5) and to the ground  
screw (GROUND) in the motor box.  
Manually rotate fan blade to ensure no obstructions before turning on the power to the fan.  
Operating Instructions  
Whole House Fans cool your home by pulling in fresh, cooler air from outside through open windows and doors.  
For best results in a multi-story home, windows should be opened on alternate levels for most efficient cooling.  
NEVER operate fan without open windows or doors.  
CAUTION: If your home has a fireplace, be sure that the flue damper is closed to prevent chimney soot  
from being drawn into the house by the fan. DO NOT operate the fan when a fire is burning in the  
fireplace.  
Common Installation Issues  
Motor Stops after 10-20 Minutes  
A tight belt tension can cause the unit to overheat.  
Insufficient intake or exhaust Net Free Air. Open more doors and windows or increase the amount of ventilation in  
the attic.  
Check the bearing assembly for resistance on belt driven models to ensure there are no rough spots.  
Unit is Noisy  
If the unit is considered to be too noisy in general, install the additional frame between the fan and mounting frame.  
Large fans will make noise while operating. Moving the fan further into the attic will reduce the apparent noise.  
Make sure you still have 36” of clearance to the roof.  
Make sure all screws and bolts are tightened.  
Ensure enough clearance above the unit, minimum of 36” from fan blades to roof.  
Verify Exhaust NFA. Inadequate NFA will result in the unit working harder and making more noise.  
Not Enough Airflow  
Verify NFA intake and exhaust requirements are being met. Lack of airflow can be the result of lack of fresh air and  
lack of ventilation to expel the air. Try channeling the air by opening only doors and windows in a certain area to  
funnel the wind flow.  
Shutter is Hitting the Fan  
Check to make sure there is enough space between the louvers and the fan. There should be around 6”-7 ½” between  
the fan blade and the vent.  
Fan Does Not Start on Low Speed  
Verify that the fan will start on High Speed. Switch to Low Speed from the High setting. For additional  
troubleshooting, please contact our customer support team.  
Ventamatic, Ltd. | 100 Washington Ave, Mineral Wells, TX 76068 Phone: (800) 433-1626 www.bvc.com  
7
VENTAMATIC, LTD.  
LIMITED WARRANTY  
Ventamatic, Ltd. extends this warranty to the original occupying owner of the home where this product is installed, that this product  
will be free from defects of material or workmanship for the time period listed by model number below:  
CX242DDWT, CX302DDWT  
Limited 10-Year  
Limited 10-Year  
CX24B2SPD, CX30BD2SPD, CX36BD2SPD  
No subsequent purchaser of the home in which the product was installed will be entitled to the benefits of this warranty. Ventamatic,  
Ltd. will replace the defective part or component only and return the new part to you freight prepaid. Customer must bear all other  
expenses incurred, including labor required for field repair or replacement, and cost of return shipping of the defective part or  
component to Ventamatic.  
Customer must also bear the cost of replacement of any part or component and the shipping charges incurred for the replacement and  
return of any part or component not covered by this warranty, including parts or components damaged by customer.  
Ventamatic, Ltd. reserves the right to demand and receive written evidence of the date of purchase before undertaking to perform its  
obligations under this warranty. YOU SHOULD, THEREFORE, RETAIN YOUR SALES SLIP FOR THE DURATION OF  
THE WARRANTY, AND ATTACH IT TO ANY EVENTUAL CLAIM. In order to obtain the replacement of a part or  
component, you must select one of the following methods:  
A) Return to factory.  
Return postage prepaid the fan or part you believe to be defective to the address below:  
Ventamatic, Ltd.  
100 Washington Street  
Mineral Wells, TX 76067  
*Include your name & address and a copy of your proof of purchase or installation.  
B) Return to place of purchase.  
It is suggested that you first contact the dealer to ascertain if they will honor the warranty.  
There is no informal dispute settling mechanism available in the event of a controversy involving this warranty.  
Any and all implied warranties shall be limited to the duration of the express warranty set forth above. In some states, limitations of  
the duration of implied warranty do not apply. Ventamatic, Ltd. shall not be liable for incidental or consequential damages, whether  
direct or indirect based upon breach of warranty, breach of contract, negligence or tort.  
If any suit or other action is brought against Ventamatic by customer, Ventamatic and customer irrevocably waive the right to trial by  
jury. Purchase and installation of this product constitutes acceptance of the terms of this warranty by customer.  
Ventamatic, Ltd. | 100 Washington Ave, Mineral Wells, TX 76068 ▪ Phone: (800) 433-1626 ▪ www.bvc.com  
8

Toshiba E Studio 282 User Manual
Sunbeam 2576 User Manual
Samsung Aq09pbge User Manual
Niles Audio Personal Emergency Reporting System Pers 2400b User Manual
LG 27EP950 User Manual
DELL VOSTRO 3669 User Manual
DELL 1909WF User Manual
BLACK DECKER LEDUC9 1W User Manual
AT&T DLP70090 User Manual
ACER AT310 F1 User Manual