Installing the oven
For USA only
All electrical work should be performed
by a licensed electrician, in strict ac-
cordance with national and local safety
regulations and standards.
The appliance is provided with 3 termi-
nal leads, 1 black wire (L1), 1 red
wire (L 2) and 1 green wire (GND)
which have to be connected to a dedi-
cated junction box. Connect the black
wire to L1, the red wire to L2 and the
green wire to GND.
Note to installer:
Please leave these instructions with
the consumer.
Power supply:
Please check the dataplate for verifi-
cation of:
240 VAC; 60 Hz
15A, 240 V
ALSO SEE THE WIRING DIAGRAM
PROVIDED WITH THE APPLIANCE.
For CDN only
L1, L2, Ground
The appliance is provided with 3 termi-
nal leads: 1 black wire, 1 red wire and
1 green wire which have to be con-
nected to a separate overcurrent pro-
tection device (fusebox or circuit
breakers).
Caution:
Disconnect main power supply be-
fore servicing. To reduce the risk of
electrical shock, make sure that the
appliance is properly grounded
after installation.
All hot wires (black and red) have to be
fused individually before connecting
them to the main power supply leads.
WARNING : THIS APPLIANCE
MUST BE GROUNDED
Use 15 Amp fuses or circuit
breakers for appliances rated 240
VAC.
Connect black terminal wire to
L1 (black) and red terminal wire to
L2 (red). The green terminal wire
(ground) has to be connected directly
to the equivalent colored power supply
leads.
All connections must be done in a
proper way.
ALSO SEE THE WIRING DIAGRAM
PROVIDED WITH THE APPLIANCE.
8