MIELE DA 279 4 User Manual

Operating and Installation  
Instructions  
Ventilation System  
DA 279-4  
en - US, CA  
To prevent accidents  
and appliance damage,  
read these instructions  
before  
installation or use.  
M.-Nr. 07 259 281  
IMPORTANT SAFETY INSTRUCTIONS  
,WARNING  
READ AND SAVE THESE  
TO REDUCE THE RISK OF  
FIRE, ELECTRIC SHOCK, OR  
INJURY TO PERSONS,  
INSTRUCTIONS  
Keep these instructions in a safe  
place and pass them on to any future  
user.  
OBSERVE THE FOLLOWING:  
a) Use this appliance only in the  
~
manner intended by the manufacturer.  
Read these instructions carefully  
before installing or using the  
Ventilation System.  
If you have questions, contact Miele.  
b) Before servicing or cleaning the  
~
appliance, switch power off at the  
service panel and lock the service  
disconnecting means to prevent power  
from being switched on accidentally. If  
the service disconnecting means  
cannot be locked, securely fasten a  
prominent warning device, such as a  
tag, to the service panel.  
This appliance is intended for  
~
residential use only. Use the appliance  
only for its intended purpose.  
This appliance complies with current  
~
safety requirements. Improper use of  
the appliance can lead to personal  
injury and material damage.  
c) Be certain your appliance is  
~
properly installed and grounded by a  
,CAUTION  
qualified technician.  
For General Ventilating Use  
Only. Do Not Use To Exhaust  
Hazardous Or Explosive  
Materials And Vapors.  
To guarantee the electrical safety of this  
appliance, continuity must exist  
between the appliance and an effective  
grounding system. It is imperative that  
this basic safety requirement be met. If  
there is any doubt, have the electrical  
system of the house checked by a  
qualified electrician.  
This appliance is designed to vent  
~
cooking smoke and odors only.  
This appliance is suitable for  
~
installation above gas or electric  
cooking surfaces.  
This appliance is not designed for  
~
maritime use or for use in mobile  
installations such as recreational  
vehicles or aircraft. However, under  
certain conditions installation in these  
applications may be possible. Please  
contact your Miele dealer or the Miele  
Technical Service Department with  
specific requirements.  
3
IMPORTANT SAFETY INSTRUCTIONS  
d) Before connecting the appliance  
Use  
~
to the power supply make sure that the  
voltage and frequency listed on the  
data plate correspond with the  
household electrical supply.  
,WARNING  
TO REDUCE THE RISK OF A  
COOKTOP GREASE FIRE:  
This data must correspond to prevent  
appliance damage. If in doubt consult a  
qualified electrician.  
a) Never leave surface units  
~
unattended at high settings. Boilovers  
cause smoking and greasy spillovers  
may ignite. Heat oils slowly on low or  
medium settings.  
e) Installation work and repairs  
~
should only be performed by a qualified  
technician in accordance with all  
applicable codes and standards.  
Repairs and other work by unqualified  
persons could be dangerous.  
b) Always turn the hood on when  
~
cooking at a high heat.  
c) Clean the ventilation hood  
~
f) Only open the housing as  
frequently. Grease should not be  
allowed to accumulate on the fan or  
filter.  
~
described in the enclosed "Installation  
diagram" and in the "Cleaning and care"  
section of this manual. Under no  
circumstances should any other parts  
of the housing be opened. Tampering  
with electrical connections or  
d) Use the proper pan size. Always  
~
use cookware appropriate for the size  
of the cooking area.  
components and mechanical parts is  
highly dangerous to the user and can  
cause operation faults.  
e) Do not flambé or grill with an  
~
open flame beneath the hood.  
Flames could be drawn up into the  
hood by the suction and the grease  
filters may catch fire.  
g) Before discarding an old  
~
appliance, disconnect it from the power  
supply and remove the power cord to  
prevent hazards.  
4
IMPORTANT SAFETY INSTRUCTIONS  
,WARNING  
Do not allow children to play with or  
~
operate the appliance or its controls.  
Supervise its use by the elderly or  
infirm.  
TO REDUCE THE RISK OF  
INJURY TO PERSONS IN THE  
EVENT OF A COOKTOP  
GREASE FIRE, OBSERVE THE  
FOLLOWING*:  
Always turn on the hood when using  
~
the cooktop to prevent damage from  
condensation.  
a) SMOTHER FLAMES with a close  
~
fitting lid, cookie sheet, or metal tray  
then turn off the burner.  
Never operate gas burners without  
~
cookware. Turn the burner off when not  
in use. Adjust the burner so that the  
flames do not extend beneath the  
cookware. Do not overheat the  
cookware, e.g. when using a wok. The  
hood can be damaged due to  
excessive heat from the burners and  
the cookware.  
BE CAREFUL TO PREVENT BURNS.  
If the flames do not go out immediately,  
EVACUATE AND CALL THE FIRE  
DEPARTMENT.  
b) NEVER PICK UP A FLAMING  
~
PAN - You may be burned.  
c) DO NOT USE WATER, including  
Do not use the hood without the  
~
grease filters in place.  
~
wet dishcloths or towels - a violent  
steam explosion will result.  
Do not use a steam cleaner to clean  
~
d) Use a fire extinguisher ONLY if:  
the hood. Steam could penetrate  
electrical components and cause a  
short circuit.  
~
1) You have a class ABC  
extinguisher, and you know how to  
operate it.  
2) The fire is small and contained in  
the area where it started.  
3) The fire department is being  
called.  
4)You can fight the fire with your  
back to an exit.  
*
Based on "Kitchen Firesafety Tips"  
published by NAFTA  
5
IMPORTANT SAFETY INSTRUCTIONS  
Installation  
g) Do not install this hood over  
~
cooktops that burn solid fuel.  
,WARNING  
h) Provided a larger distance is not  
~
TO REDUCE THE RISK OF  
FIRE, ELECTRIC SHOCK, OR  
INJURY TO PERSONS,  
OBSERVE THE FOLLOWING:  
given by the manufacturer of the  
cooktop, follow the minimum safety  
distances between a cooktop and the  
bottom of the hood given in the  
"Appliance dimensions" section of this  
manual.  
a) Installation work and electrical  
~
wiring must be done by qualified  
person(s) in accordance with all  
applicable codes and standards,  
including fire-rated construction.  
If local building codes require a greater  
safety distance, follow their  
requirement.  
If there is more than one appliance  
beneath the hood and they have  
different minimum safety distances  
always select the greater distance.  
b) Sufficient air is needed for  
~
combustion and exhausting of gases  
through the flue (chimney of fuel  
burning equipment to prevent back  
drafting. Follow the heating equipment  
manufacturer’s guideline and safety  
standards such as those published by  
the National Fire Protection Association  
(NFPA) and the American Society for  
Heating, Refrigeration and Air  
i) Never connect an exhaust hood to  
~
an active chimney, dryer vent, vent flue,  
or room ventilating ductwork.  
j) Seek professional advice before  
~
connecting an exhaust hood vent to an  
existing, inactive chimney or vent flue.  
Conditioning Engineers (ASHRAE), and  
the local code authorities.  
k) Any fittings, sealant, or materials  
~
used to install the ductwork must be  
made of approved non-flammable  
materials.  
c) When cutting or drilling into the  
~
wall or ceiling, do not damage electrical  
wiring and other hidden utilities.  
d) Ducted hoods must always be  
~
vented to the outdoors.  
,WARNING  
TO REDUCE THE RISK OF  
FIRE USE ONLY METAL  
DUCTWORK.  
e) Do not use this hood with any  
~
solid-state speed control device.  
f) Do not use an extension cord to  
~
connect the appliance to electricity.  
Extension cords do not guarantee the  
required safety of the appliance,  
(e.g. danger of overheating).  
6
Functional description  
The hood offers two modes of  
operation:  
Air extraction  
Recirculation mode  
The air is drawn in and cleaned by the  
grease filters and directed outside.  
Air is drawn through the grease filters  
and an active charcoal filter. The  
filtered air is then recirculated back into  
the kitchen through a vent at the top of  
the hood’s chimney.  
The hood comes equipped with a  
non-return flap. This flap automatically  
closes when the hood is turned off so  
that no exchange of outside air and  
room air can occur. When the hood is  
turned on, the air pressure of the  
exhaust fan automatically opens the  
flap blowing the inside air and cooking  
odors outside.  
The recirculation mode requires an  
install kit and charcoal filter which are  
optional accessories.  
Before using the hood in  
recirculation mode, ensure that the  
active charcoal filter is in place, see  
"Cleaning and care".  
7
Guide to the Ventilation System  
8
Guide to the Ventilation System  
a Chimney extension  
b Chimney  
o Grease filter button  
The indicator next to the grease filter  
button lights when the grease filters  
need to be cleaned. This button is also  
used:  
c Canopy  
– to reset the grease filter timer after  
cleaning the grease filters (see  
"Cleaning and Care").  
d Control panel  
e Grease filter  
– to show how long the grease filters  
have been in use (see "Operation/  
Filter timers").  
f Recirculation vent  
g Indirect lighting  
h Overhead lighting  
– to change the number of hours  
counted by the grease filter timer  
(see "Operation/Reprogramming the  
timers").  
i Charcoal filter  
p Charcoal filter button  
optional accessory  
The indicator next to the charcoal filter  
button lights when the charcoal filter  
needs to be replaced.  
j Indirect light button  
This button is also used:  
k Overhead light button  
– to reset the charcoal filter timer after  
changing the filter (see "Cleaning  
and care").  
This button turns the light on and off  
and also dims the light.  
The lighting can be used independently  
from the fan.  
– to show how long the charcoal filter  
has been in use (see "Operation/  
Filter timers").  
l On/Off button  
– to change the number of hours  
counted by the charcoal filter timer  
(see "Operation/Reprogramming the  
timers").  
m Fan power selection  
Four fan speed selection  
n Delayed Shut Down  
This button activates the Delayed Shut  
Down feature. The fan can be set to  
turn off automatically after either 5 or 15  
minutes.  
9
Operation  
Turning on the fan  
Automatically switching back the  
Intensive power level  
The intensive level "4" can be  
programmed to automatically switch  
back to level "3" after 10 minutes.  
^ Press the On/Off button.  
^ Turn the fan and the lights off.  
Selecting the power level  
^ Press and hold the Delay Shut Down  
button for 10 secs. The first indicator  
of the fan power levels lights.  
^ Use the "/+" controls to select the  
desired power level.  
^ Press the following buttons one after  
+ = increases the fan speed  
another,  
= decreases the fan speed  
Level "1" to "3" (green indicators) are  
usually sufficient for normal cooking.  
Intensive setting  
– the right light button,  
Level "4" (yellow indicator) should only  
be used for short periods of time when  
frying or cooking food with a strong  
aroma.  
– the "" button, and  
– the right light button again.  
10  
Operation  
Fan performance  
The maximum air flow capacity is  
625 cfm. Factors such as narrow duct  
diameter and bends will affect this  
value.  
If the power level indicators "1" and "4"  
flash the automatic switch back is not  
activated.  
Level 1 operates at 40% capacity  
Level 2 operates at 60% capacity  
Level 3 operates at 80% capacity  
Level 4 operates at 100% capacity  
^ To activate the automatic switch back  
press the "+" button.  
The power level indicators "1" and "4"  
light.  
There will also be a slight decrease in  
airflow for hoods operated in  
recirculation mode due to the active  
charcoal filter.  
^ To deactivate the automatic switch  
back press the "" button.  
^ To save the setting press the Delay  
Shut Down button.  
If the procedure is not stored within  
4 minutes of programming, the hood  
will automatically default to the "old"  
data.  
11  
Operation  
Delayed Shut Down  
Turning off the fan  
If odors or smoke remain in the kitchen  
after cooking has been completed, the  
Delayed Shut Down feature can be  
selected to allow the hood to continue  
running for either 5 or 15 minutes.  
^ Press the On/Off button to turn the  
fan off.  
The indicator will go out.  
Automatic Safety Shut Off  
^ Press the Delayed Shut Down button  
The fan will turn off automatically  
10 hours after the last button was  
activated. The lighting however will  
remain on.  
while the fan is still running.  
Press once = 5 minute delay  
(left indicator lights)  
Press twice = 15 minute delay  
(right indicator lights)  
^ Press the On/Off button to turn the  
fan back on again.  
To cancel the Delayed Shut Down  
feature press the button again.  
12  
Operation  
Turning the lighting on/off  
Indirect lighting  
The overhead lighting can be turned on  
and off independently from the fan.  
^ Turn the indirect lighting on and off  
with the left light button.  
^ Press the right light button briefly to  
^ The indirect lighting can be operated  
turn on the lighting.  
independently from the fan.  
The light button indicator illuminates.  
^ Press the right light button briefly  
again to turn off the lighting.  
The light button indicator will go out.  
Dimming the lighting  
The brightness of the lighting can be  
adjusted.  
^ While the lighting is turned on, press  
the right light button.  
The lighting will dim until the button is  
released.  
^ If the button is pressed again, the  
lighting will brighten until the button is  
released.  
If the button is pressed continuously,  
the light will cycle between bright and  
dark.  
^ Press the light button again to turn off  
the lighting.  
13  
Operation  
Filter timers  
Checking the filter timers  
To check the percentage of time  
already used:  
Grease filters  
A timer monitors the hours of fan  
operation. The indicator for the grease  
filter will light after 30 hours of  
operation. The grease filters must then  
be cleaned.  
^ Press the On/Off button to turn the  
fan on.  
After the grease filters have been  
cleaned and put in place, the grease  
filter timer must be reset.  
^ To do this, press the grease filter  
button for about 3 seconds.  
^ Press and hold the grease or  
charcoal filter button.  
The indicator will go out.  
The number of flashing "/+" indicators  
show the percentage of programmed  
hours that have been used.  
Charcoal filter  
Recirculation mode only  
The timer for the charcoal filter is not  
preset. Please program this timer, see  
"Operation/Reprogramming the  
charcoal filter timer".  
1 indicator = less than 25 %  
2 indicators = less than 50 %  
3 indicators = less than 75 %  
4 indicators = less than 100 %  
The charcoal filter indicator will light  
once the selected time has elapsed.  
The charcoal filter must then be  
replaced and the charcoal filter timer  
reset.  
This information will remain stored in  
memory in the event of a power failure.  
^ To do this, press the charcoal filter  
button for about 3 seconds.  
The indicator will go out.  
14  
Operation  
Reprogramming the timers  
The grease filter timer is preset to 30  
hours. This time can be lengthened or  
shortened to 20, 30, 40, or 50 hours.  
The indicator for the grease filter and  
– A time of 20 hours should be  
programmed in kitchens with  
frequent pan or deep frying.  
one of the "/+" indicators will flash.  
The lit indicator shows the programmed  
time:  
– A time of 20 hours should also be  
programmed if the kitchen is only  
used occasionally to prevent grease  
which has accumulated over a long  
period of time from hardening on the  
filters, making cleaning more difficult.  
1st indicator from the left = 20 hours  
2nd indicator from the left = 30 hours  
3rd indicator from the left = 40 hours  
4th indicator from the left = 50 hours  
^ Use the "/+" button to select the  
desired time.  
Reprogramming the grease filter  
timer  
^ Store the selection by pressing the  
grease filter button.  
^ Press the On/Off button to turn off the  
If the procedure is not stored within  
4 minutes of programming, the hood  
will automatically default to the "old"  
data.  
fan.  
^ Press the Delayed Shut Down and  
grease filter buttons at the same time.  
15  
Operation  
Reprogramming the charcoal filter  
timer  
The active charcoal filter can only be  
used in recirculation mode and cannot  
be used to exhaust fumes.  
The indicator for the charcoal filter and  
one of the "/+" indicators will flash.  
The charcoal filter timer is not preset.  
The lit indicator shows the programmed  
time:  
Before using the hood in recirculation  
mode, the charcoal filter timer must be  
programmed.  
1st indicator from the left = 120 hours  
2nd indicator from the left = 180 hours  
3rd indicator from the left = 240 hours  
4th indicator from the left = deactivated  
^ Use the "/+" button to select the  
desired time.  
^ Turn off the fan using the On/Off  
button.  
^ Store the selection by pressing the  
^ Press the Delayed Shut Down and  
charcoal filter buttons at the same  
time.  
charcoal filter button.  
If the procedure is not stored within  
4 minutes of programming, the hood  
will automatically default to the "old"  
data.  
16  
Cleaning and Care  
,WARNING  
Avoid:  
TO REDUCE THE RISK OF  
FIRE, ELECTRIC SHOCK, OR  
INJURY TO PERSONS,  
OBSERVE THE FOLLOWING:  
– cleaning agents containing soda,  
acids or chlorides,  
– abrasive cleaning agents  
e.g. powder or cream cleansers,  
– abrasive sponges, e.g. pot scourers  
or sponges which have been  
previously used with abrasive  
cleaning agents,  
Before cleaning or servicing the  
hood, disconnect it from the power  
supply, see "Important Safety  
Instructions".  
– limescale removers.  
Cleaning the casing  
These will damage the surface.  
Never use abrasive cleaners,  
scouring pads, steel wool or caustic  
(oven) cleaners on the hood. They  
will damage the surface.  
The following instructions for cleaning  
"Stainless steel" surfaces and "Stainless  
steel colored controls" should be  
followed in addition to the general  
"Cleaning the casing" instructions.  
^ All external surfaces and controls can  
be cleaned with a mild solution of  
warm water and liquid dish soap  
applied with a soft sponge.  
Stainless steel  
Stainless steel surfaces can be cleaned  
using a non-abrasive stainless steel  
cleaner.  
^ Wipe dry using a soft cloth.  
To help prevent resoiling, a conditioner  
for stainless steel can be applied.  
Do not use too much water when  
cleaning the controls. Water could  
penetrate the electronics and cause  
damage.  
Stainless steel colored controls  
These controls may become dis-  
colored or damaged if not cleaned  
regularly.  
^ Glass surfaces can be cleaned using  
a glass cleaner.  
Do not use a stainless steel cleaner  
on these controls.  
17  
Cleaning and Care  
Grease filters  
^ In a dishwasher: place the filters  
vertically in the lower basket, making  
sure that the spray arm is not  
blocked.  
The reusable metal grease filters  
remove solid particles from the vented  
kitchen air (grease, dust, etc).  
Use a hot temperature program, e.g.  
"Heavy Soil" or "Pots and pans".  
Use the recommended amount of  
dishwasher detergent. Overuse could  
destroy the filter.  
The grease filters should be cleaned  
every 3 - 4 weeks, when the grease  
filter indicator lights, or when they are  
visibly dirty, whichever comes first.  
Depending on the detergent,  
cleaning the grease filters in a  
dishwasher may cause permanent  
discoloration of the filter surface.  
Performance of the filter will not be  
affected by this discoloration.  
,A dirty filter is a fire hazard.  
^ After cleaning, the filters can be  
placed on a towel to air dry.  
^ While the filters are removed, clean  
any dirt or grease from the filter  
casing to prevent the risk of fire.  
When putting the grease filters back  
make sure that the locking clips are  
visibly facing the cooking surface.  
If the filters are incorrectly installed,  
insert a small screwdriver into the slit  
along its edge to disengage it from the  
casing.  
^ To remove the grease filters pull the  
locking clips forward. Lower the filter  
45° unhook it at the rear and take it  
out. Support the grease filter so that it  
does not fall onto the cooktop.  
^ After returning the grease filters,  
press and hold the grease filter  
button for 3 seconds to reset the  
timer. The indicator light will go out.  
Cleaning the grease filters  
^ By hand: use a scrub brush with a  
solution of warm water and mild  
detergent.  
^ If the grease filters are cleaned  
before the grease filter timer has  
reached its maximum, press the  
grease filter button for 6 seconds to  
reset the counter to zero.  
Do not use the pure detergent,  
aggressive all purpose cleaners,  
oven sprays or limescale removers.  
They could destroy the filters.  
18  
Cleaning and Care  
Active charcoal filter  
In recirculation mode an active  
charcoal filter must be used in addition  
to the grease filters. It is designed to  
absorb cooking odors.  
The active charcoal filter will be  
replaced in the canopy above the  
grease filters.  
^ Insert the charcoal filter.  
Replacement active charcoal filters  
can be ordered from Miele.  
Before using:  
^ Program the charcoal filter timer, see  
"Operation / Reprogramming the  
charcoal filter timer".  
^ Remove the grease filters to access  
the charcoal filter. See "Cleaning and  
Care - Grease filters".  
Replace the active charcoal filter when  
the charcoal filter indicator lights, at  
least every 6 months or when they no  
longer absorb odors efficiently.  
^ After replacing the charcoal filter,  
press and hold the charcoal filter  
button for about 3 seconds to reset  
the charcoal filter timer.  
The indicator light will go out.  
^ If the charcoal filter is replaced  
before the timer has reached its  
maximum, the charcoal filter button  
should be pressed for 6 seconds to  
reset the counter to zero.  
19  
Cleaning and Care  
Changing the light bulbs  
,WARNING  
TO REDUCE THE RISK OF  
FIRE, ELECTRIC SHOCK, OR  
INJURY TO PERSONS,  
OBSERVE THE FOLLOWING:  
Before changing the light bulbs,  
disconnect the hood from the power  
supply, see "Important Safety  
Instructions".  
When in use halogen bulbs become  
extremely hot, and can burn your  
hands. Do not attempt to change the  
bulbs until they have had sufficient  
time to cool.  
^ To change the halogen bulb, first  
gently press the light cover. The  
cover will open and can now be  
flipped down.  
Do not touch the bulb surface.  
Fingerprints or body oils deposited  
on the bulb will decrease its life.  
Please follow the manufacturer’s  
instructions.  
^ Pull the halogen bulb from its socket,  
then insert a new bulb.  
^ Flip the light cover back up, making  
sure it clicks into place.  
20  
After Sales Service  
Repairs  
MieleCare  
In the event of a fault which you cannot  
easily fix yourself, please contact the  
Miele Technical Service Department.  
(USA only)  
MieleCare, our Extended Service  
Contract program, gives you the  
assurance of knowing that your  
^ When contacting the Technical  
Service Department, please quote  
the model and serial number of your  
appliance.  
appliance investment is covered by  
5 years of worry free ownership.  
MieleCare is the only Extended Service  
Contract in the industry that guarantees  
repairs by a Miele Authorized Service  
Provider using genuine Miele parts.  
Only genuine Miele parts installed by  
factory trained professionals can  
guarantee the safety, reliability, and  
longevity of your Miele appliance.  
These are shown on the data plate  
which is visible when the grease filters  
are removed.  
Please note that unless expressly  
approved in writing by Miele’s Service  
department, Extended Service  
Contracts offered by other providers for  
Miele products will not be recognized  
by Miele. Our goal is to prevent  
unauthorized (and untrained) service  
personnel from working on your Miele  
products, possibly doing further  
damage to them, you and/or your  
home.  
To learn more about MieleCare  
Extended Service Contracts, please  
contact your appliance dealer or visit  
us online at:  
21  
22  
Installation Instructions  
Read these instructions and the  
"Important Safety Instructions"  
before installing this hood.  
The installation steps are described in  
the enclosed "Installation Diagram".  
Leave these instructions with this  
appliance for the consumer/user.  
24  
Caring for the environment  
Disposal of packing material  
Disposal of an old appliance  
The cardboard box and packing  
materials protect the appliance during  
shipping. They have been designed to  
be biodegradable and recyclable.  
Please recycle.  
Old appliances may contain materials  
that can be recycled. Please contact  
your local recycling center about the  
possibility of recycling these materials.  
Before discarding an old appliance,  
disconnect it from the electrical  
,DANGER  
Ensure that any plastic wrappings,  
bags, etc., are disposed of safely  
and kept out of the reach of babies  
and young children. Danger of  
suffocation!  
supply and cut off the power cord to  
prevent it from becoming a hazard.  
25  
Appliance dimensions  
1) Air extraction mode  
4) and 5) Cut out area in wall or  
ceiling for entrance of 6"  
(150 mm) ductwork or 5"  
(125 mm) ductwork with a reducing  
collar.  
2) Recirculation mode  
3) Air extraction vent installed upwards  
For recirculation mode only 4)  
and outlet installation are needed.  
26  
Appliance dimensions  
Distance between cooktop and  
hood (S)  
Be sure to follow the minimum safety  
distances given by the gas cooktop  
manufacturer to easily flammable  
materials e.g. upper cabinets.  
Do not install this exhaust hood over  
cooktops burning solid fuel.  
If local building codes require a  
greater safety distance, follow their  
requirement.  
Provided a larger distance is not  
given by the manufacturer of the  
cooktop, follow the minimum safety  
distances between a cooktop and  
the bottom of the hood:  
If there is more than one appliance  
beneath the hood and they have  
different minimum safety distances  
always select the greater distance.  
Miele cooktops:  
- 24" (610 mm) above electric  
surfaces,  
- 26" (660 mm) above electric  
grill/boiler/fryers,  
The installation procedure differs  
depending on the model and venting  
method.  
- 24" (610 mm) above gas surfaces  
ß 25,000 BTU's (7.5 kW) and no  
burner greater than 10,250 BTU's  
(3 kW) ,  
Before beginning the installation:  
^ Read all instructions.  
- 30" (762 mm) above gas surfaces  
> 25,000 BTU's (7.5 kW),  
- 30" (762 mm) above burner heads  
> 10,250 BTU's (3 kW). For  
example, a Wok used separately  
or in combination with a cooktop.  
Non-Miele cooktops:  
^ Determine height (S), regarding the  
user’s body height, i.e. a comfortable  
height for the user.  
However, the greater the distance,  
the less effectively cooking odors are  
drawn in.  
- 24" (610 mm) above all electric  
surfaces,  
^ If the hood is fitted flush to the  
ceiling, regard the possible unit  
height when selecting the installation  
height.  
- 30" (762 mm) above all gas  
surfaces,  
- 26" (660 mm) above electric  
grill/boiler/fryers.  
If several gas surfaces are installed  
under the hood, the total output must  
be considered when determining the  
minimum safety distance.  
27  
Appliance dimensions  
Standard unit height H  
Air Extraction . . . . . . . . . . . . 27" - 39 3/4"  
. . . . . . . . . . . . . . . . . . (685 - 1010 mm)  
Recirculation . . . . . . . . 32 5/16 - 44 11/16"  
. . . . . . . . . . . . . . . . . . (820 - 1135 mm)  
To fit the lower chimney section, the  
distance between the top of the  
chimney and the ceiling must be at  
least 7/8" (20 mm).  
28  
Plywood backing  
^ Find the studs to the left and right of  
the mounting location by tapping the  
wall or using a stud finder.  
The majority of the weight of the  
installed ventilation system will be  
supported by the lower retaining  
plate. It must be firmly attached to  
the stud framing behind the drywall.  
If studs are not available in the  
required locations, a plywood  
backing (min. ½" (13 mm) thick)  
spanning at least two studs must be  
installed. Failure to adequately  
support the weight as stated may  
result in the ventilation system falling  
off the wall, causing personal injury  
and property damage.  
^ Mark a vertical cutting line along the  
center of each stud.  
,CAUTION  
When cutting or drilling into the wall  
or ceiling, do not damage electrical  
wiring and other hidden utilities.  
^ Remove the drywall between the  
cutting lines and replace it with  
plywood of a matching thickness  
(min. ½" (13 mm) thick). Tape the  
joints and refinish the wall.  
(If plywood backing is not needed,  
proceed to the included "Installation  
diagram".)  
^ Proceed to the enclosed "Installation  
diagram" to complete the installation.  
To install a plywood backing  
^ Determine and mark the location of  
the retaining plate for the canopy as  
outlined on the "Installation diagram".  
^ Make a cutting line 3" (76 mm) above  
and 3" (76 mm) below the outline of  
the retaining plate.  
29  
Installation  
30  
Installation  
a
3 protective shields  
to prevent scratches to the chimney  
during installation.  
8 large headed screws 5 x 40 mm  
b
ducting.  
2 hose clips for securing the  
for securing the retaining plates and the  
canopy.  
c
for use with 5" (125 mm) exhaust  
ducting.  
1 reducing collar  
(S8 wall anchors included in the  
packaging are not for use in USA / CDN.)  
d Telescopic retaining plate  
secures the chimney extension.  
2 M 6 locking nuts for securing the  
e
mode; contains diverter and hose  
(optional accessory)  
Installation kit for recirculation  
motor assembly.  
2 screws 3.9 x 7.5 mm for securing the  
,CAUTION  
chimney.  
To avoid risk of hand or other injury,  
avoid contact with sharp edges  
during the assembly and installation  
process.  
1 allen wrench  
for adjusting the unit height  
1 lever for dismantling the chimney  
Installation diagram  
31  
Installation  
Installation instructions  
Dismantling  
^ See the enclosed installation  
If the hood needs to be disassembled,  
follow the instructions on the  
"Installation diagram" in the reverse  
order.  
instruction diagram.  
^ Please read the "Important Safety  
Instructions" and Installation  
instructions before installing this  
hood.  
A lever is enclosed for easier removal  
of the chimney extension.  
Protective film  
The casing is covered with a protective  
film to prevent scratching during  
transport.  
^ Peel off the film before installing the  
casing parts.  
^ After removing the screws from the  
chimney, slide the lever between the  
chimney and the chimney extension  
and gently apply pressure to ease  
the chimney from its hooks.  
32  
Air extraction  
Exhaust ducting and connections  
,WARNING  
– The ducting should be as short and  
straight as possible, and the number  
of sharp bends should be minimized.  
Danger of toxic fumes.  
Gas cooking appliances release  
carbon monoxide that can be  
harmful or fatal if inhaled.  
To reduce the risk of fire and to  
properly exhaust air, the exhaust  
gases extracted by the hood  
should be vented outside of the  
building only.  
– For most efficient air extraction, the  
diameter of the ductwork should not  
be less than 6" (150 mm). Use of flat  
ducts also reduces the air extraction  
efficiency.  
– Noise levels of the hood will increase  
if flat ducts or round ducts of less  
than 6" (150 mm) in diameter are  
used.  
Do not vent exhaust air into  
– Use smooth or flexible pipes made  
from approved non-flammable  
materials for exhaust ducting.  
spaces within walls or ceilings or  
in attics, crawl spaces or garages.  
To reduce the risk of fire, only use  
metal ductwork.  
– Where the ductwork is horizontal, it  
must slope away from the hood at  
least 1/8" per foot (1 cm per meter) to  
prevent condensation dripping into  
the appliance.  
Please read and follow the  
"IMPORTANT SAFETY  
INSTRUCTIONS" to reduce the risk of  
personal injury. Follow all local building  
codes when installing the hood.  
– If the exhaust is ducted through an  
outside wall, a Telescopic Wall Vent  
can be used.  
33  
Air extraction  
Condensate trap  
optional accessory  
– If the exhaust is ducted into an  
inactive flue, the air must be expelled  
parallel to the flow direction of the  
flue.  
In some cases, a condensate trap may  
also be required to collect and  
evaporate any condensate which may  
occur. This optional accessory is  
available for ducts 5" (125 mm) and 6"  
(150 mm) in diameter.  
Never connect an exhaust hood to  
an active chimney, dryer vent, flue,  
or room venting ductwork. Seek  
professional advice before  
connecting an exhaust hood vent to  
an existing, inactive chimney or vent  
flue.  
^ When installing a condensate trap,  
ensure that it is positioned vertically  
and if possible directly above the  
exhaust outlet.  
Important  
If the ductwork runs through rooms,  
ceilings, garages, etc. where  
temperature variations exist, it may  
need to be insulated to reduce  
condensation.  
34  
Electrical connection  
,WARNING  
Grounding Instructions  
TO REDUCE THE RISK OF  
FIRE, ELECTRIC SHOCK, OR  
INJURY TO PERSONS,  
OBSERVE THE FOLLOWING:  
This appliance must be grounded. In  
the event of an electrical short circuit,  
grounding reduces the risk of electric  
shock by providing a path of least  
resistance. This appliance is equipped  
with a cord having a grounding wire  
with a grounding plug. The plug must  
be plugged into an outlet that is  
All electrical work should be  
performed by a qualified electrician  
in strict accordance with national  
regulations (for USA: ANSI-NFPA 70)  
and local safety regulations.  
Installation, repairs and other work  
by unqualified persons could be  
dangerous.  
properly installed and grounded.  
WARNING - Improper grounding can  
result in a risk of electric shock.  
If there is any doubt, have the electrical  
system of the house checked by a  
qualified electrician.  
Ensure that power to the appliance  
is off while installation or repair work  
is performed.  
Do not use an extension cord. If the  
power supply cord is too short, have a  
qualified electrician install an outlet  
near the appliance.  
^ Verify that the voltage, load and  
circuit rating information found on the  
data plate (located behind the  
grease filters), match the household  
electrical supply before installing the  
hood.  
Important  
The hood comes equipped with a 4 ft  
(1.2 m) power cord with a NEMA 5-15  
molded plug for connection to a  
^ Use only with ventilation hood  
cord-connection kits that have been  
investigated and found acceptable  
for use with this model hood.  
120 VAC, 60 Hz, 15 A power outlet.  
If there is any question concerning the  
electrical connection of this appliance  
to your power supply, please consult a  
licensed electrician or contact Miele’s  
Technical Service Department.  
U
V
1-800-999-1360  
1-800-565-6435  
WARNING:  
THIS APPLIANCE MUST BE  
GROUNDED  
35  
Technical data  
Maximum load . . . . . . . . . . . . . . 420 W  
Overhead lighting . . . . . . . . . . 3 x 20 W  
Indirect lighting . . . . . . . . . . . . . . . 10 W  
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V  
Frequency . . . . . . . . . . . . . . . . . . 60 Hz  
Circuit rating. . . . . . . . . . . . . . . . . . 15 A  
Weight . . . . . . . . . . . . . . 70.5 lb (32 kg)  
36  
37  
38  
39  
Alteration rights reserved / 1009  
M.-Nr. 07 259 281 / 00  
For most the updated manual see the Miele website.  

Vtech Telephone Ls6325 User Manual
Sanyo Kr 1700au User Manual
Sanyo Ch3682 User Manual
Samsung Uq24a1 2 Rcd User Manual
Samsung Aw0750 User Manual
Samsung As12w User Manual
Royal Sovereign Arp 9411 User Manual
JVC DLA RS3100K User Manual
Ge 33691 User Manual
DIMPLEX PF3033 User Manual