MAYTAG MMV4205FW 02 User Manual

Microwave Hood Combination  
PRODUCT MODEL NUMBERS  
PRODUCT DIMENSIONS  
MMV4205F  
MMV5219F  
ELECTRICAL REQUIREMENTS  
Observe all governing codes and ordinances.  
Required:  
16¹⁄₄"  
(41.3 cm)  
17¹⁄₈"  
A 120 volt, 60 Hz, AC only, 15- or 20-amp electrical supply with a fuse  
or circuit breaker.  
(43.5 cm)  
+/- ³⁄₁₆"  
(0.5 cm)  
Recommended:  
A time-delay fuse or time-delay circuit breaker.  
A separate circuit serving only this microwave oven.  
VENTING DESIGN SPECIFICATIONS  
This section is intended for architectural designer and builder/contractor  
reference only.  
NOTES:  
* Overall depth of product will vary slightly depending on door design.  
Vent materials needed for installation are not provided with microwave  
hood combination.  
INSTALLATION DIMENSIONS:  
NOTE: The grounded 3 prong outlet must be inside the upper cabinet.  
See “Electrical Requirements” section.  
We do not recommend using a flexible metal vent.  
To avoid possible product damage, be sure to vent air outside, unless  
using recirculation installation. Do not vent exhaust air into concealed  
spaces, such as spaces within walls or ceilings, attics, crawl spaces  
or garages.  
A
B
For optimal venting installation, we recommend:  
Using roof or wall caps that have back draft dampers.  
Using a rigid metal vent.  
12" (30.5 cm) min.  
14" (35.6 cm) max.  
upper cabinet and  
side cabinet depth  
30"  
(76.2 cm)  
min.  
Using the most direct route by minimizing the length of the vent and  
number of elbows to provide efficient performance.  
30"  
(76.2 cm)  
typical*  
Using uniformly sized vents.  
Using duct tape to seal all joints in the vent system.  
Using caulking compound to seal exterior wall or roof opening around  
cap.  
66" (167.6 cm) min.  
Not installing 2 elbows together for optimal hood performance.  
If venting through the wall, be sure that there is proper clearance within  
the wall for the damper to open fully.  
If venting through the roof, and rectangular to round transition is used,  
be sure there is at least 3" (7.6 cm) of clearance between the top of the  
microwave oven and the transition piece. See “Rectangular to Round  
Transition” illustration.  
A. 2" x 4" wall stud  
B. Grounded 3 prong outlet  
* 30" (76.2 cm) is typical for 66" (167.6 cm) installation height. Exact  
dimensions may vary depending on type of range/cooktop below.  
Roof venting  
Roof cap  
Wall venting  
Wall cap  
Page 1 of 2  
Because Whirlpool Corporation includes a continuous commitment to improve our  
products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10823835A  
06/30/2016  

York Sunline 2000 D7cg 036 User Manual
Whirlpool Acs802xv User Manual
Trion Cm Series User Manual
Sennheiser L151 10 User Manual
Panasonic Dp 8045 User Manual
MAKITA HR2630T User Manual
HANSGROHE AXOR PHOENIX 17385XX1 User Manual
HAMILTON BEACH C33567 User Manual
CANON SPEEDLITE 270EX User Manual
ASUS VZ249HE User Manual