LG LDE3015SB User Manual

INSTALLATION MANUAL  
ELECTRIC DOUBLE  
OVEN RANGE  
Please read these instructions thoroughly before  
installing and operating the range.  
LDE3019ST  
LDE3017ST  
LDE3017SB  
LDE3017SW  
LDE3015ST  
LDE3015SB  
LDE3015SW  
LDE3011ST  
LDE3037ST  
LDE3037SB  
LDE3037SW  
LDE3031ST  
LDE3035ST  
LDE3035SB  
LDE3035SW  
SAFETY  
3
BEFORE YOU BEGIN  
Remove all tape and packing materials before using the range.  
Dispose of all plastic bags after unpacking the range. Never allow children to play with packing materials.  
IMPORTANT SAFETY INSTRUCTIONS  
Read and follow all instructions before using your oven to prevent the risk of fire, electric shock, personal injury, or  
damage when using the range. This guide does not cover all possible conditions that may occur. For further assistance  
contact your service agent or manufacturer.  
This is the safety alert symbol. This symbol alerts you to potential hazards that can cause personal injury to  
you and others. All safety messages will follow the safety alert symbol with either the word “WARNING” or  
“CAUTION.  
WARNING  
This symbol will alert you to hazards or unsafe practices which could cause serious bodily harm or death.  
CAUTION  
This symbol will alert you to hazards or unsafe practices which could cause bodily injury or property damage.  
WARNING  
• The information in this manual should be followed exactly.  
- A fire or electrical shock may result causing property damage, personal injury or death.  
• Any person should not step or sit on the oven door. You should install the Anti-Tip Bracket supplied with  
the range.  
- The range could be tipped and injury might result from spilled hot liquid, food, or the range itself.  
- If the range is pulled away from the wall for cleaning, service, or any other reason, ensure that the Anti-Tip  
Device is properly reengaged when the range is pushed back against the wall.  
- Install the Anti-Tip Bracket. Screws must be fixed to at least two locations.  
- A child or adult can tip the range and be killed.  
- Failure to do so can result in death or serious burns to children or adults.  
- 1) According to the Anti-Tip Bracket Template, install Anti-Tip Bracket to the floor and wall.  
- Anti-Tip will fasten the range by holding the range’s leg from the rear side and the Anti-Tip Bracket Template  
lets you know the location of Anti-Tip Bracket easily.  
- 2) Engage the range to the Anti-Tip Bracket by putting the range’s legs into each Anti-Tip Bracket.  
- 3) Re-engage the Anti-Tip Bracket if you can move the range without oven’s front direction.  
- 4) See installation instructions for details (refer to the page 11).  
You should use two or more people to move and install range. (Excessive Weight Hazard)  
- Failure to do so can result in back or other injury.  
You never pull or push any handles of upper& lower door to move and install range.  
- Failure to do so can result in serious damage to the door of the range.  
• New branch-circuit installations (1996 NEC) for mobile homes, recreational vehicles, and installations  
where local codes do not allow grounding through the neutral wire require a 4-conductor UL listed range  
cord or 4 wire conduit connection.  
• Power supply cord and plug should not be modified. If it will not fit the outlet, have a proper outlet  
Installed by a qualified electrician.  
SAFETY  
4
WARNING  
• Using an extension cord to connect the power is prohibited.  
The way to connect the power cord and plug directly is strongly recommended.  
• Electrical ground is required on this appliance.  
You should make sure that the power cord is not pinched by the range or heavy objects.  
- Failure to do so can result in serious burns or electrical shock.  
You never remove the protection cover covering the rear of lower oven.  
- Failure to do so can result in serious damage to power cord. The damage causes serious burns and electric  
shock.  
• The middle (neutral or ground) wire of a 3 wire power cord or a 3 wire conduit has to be connected to the  
middle post of the main terminal block. The remaining two wires of the power cord or conduit have to be  
connected to the outside posts of the main terminal connection block.  
- Failure to do so can result in electrical shock, severe personal injury or death.  
• Only a 4-conductor power-supply cord kit rated 120/240 volts, 50 amperes and marked for use with  
ranges with closed-loop connectors or open-end spade lugs with upturned ends shall be used. The  
middle (neutral) wire of the power cord or 4-wire conduit has to be connected to the middle post of  
the main terminal block. The other two wires of the power cord or conduit have to be connected to the  
outside posts of the main terminal connection block. The 4th ground wire must be connected to the  
frame of the range with the ground screw.  
- Failure to do so can result in electrical shock, severe personal injury or death.  
CAUTION  
You should put on gloves during the installation procedure.  
- Failure to do so can result in bodily injury.  
You should make sure that the wall covering, countertop and cabinets around the range can withstand  
the heat (up to 194°F) generated by the range.  
- Discoloration, delamination or melting may occur.  
- This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194°F.  
• Cabinet storage space located above the surface units should be avoided.  
You should install a range hood that projects horizontally a minimum of 5 inches beyond the bottom of  
the cabinets. If cabinet Storage is to be provided.  
- The risk of burns or fire by reaching over the heated surface elements can be reduced.  
You should not install the range in the humid place. Splashing the range with water or any electrolyte can  
result in electrical shock.  
You should not let cooking grease or flammable material accumulate in or near the range.  
- Failure to do so can result in serious burns.  
SAFETY  
5
PREPARE TO INSTALL THE RANGE  
WARNING  
• The information in this manual should be  
followed exactly.  
TOOLS NEEDED  
- A fire or electrical shock may result causing  
property damage, personal injury or death.  
Phillips Screwdriver  
Level  
WARNING  
Tip - Over Hazard  
Flat-blade  
Screwdriver  
Adjustable Wrench  
A child or adult can tip the range and be  
killed. Verify the anti-tip bracket have been  
installed. Ensure the anti-tip bracket is  
enganged when the range is moved.  
Do not operate the range without the anti-  
tip bracket in place. Failure to follow these  
instructions can result in death or serious  
burns to children and adults.  
1/4Nut Driver  
Drill  
Pliers  
To check visually that leveling leg is inserted  
into bracket, grasp the top rear edge of the  
range and carefully attempt to tilt it forward.  
Safety Glasses  
Leveling  
leg  
bracket  
Tape Measure  
CAUTION  
You should put on gloves during the installation  
procedure.  
Pencil  
Gloves  
- Failure to do so can result in bodily injury.  
PARTS PROVIDED  
Template (1)  
NOTE  
• Read all instructions contained in these installation  
instructions before installing range.  
• Remove all packing materials from the oven  
compartments before connecting the electrical  
supply to the range.  
Anti-Tip Bracket Kit (1)  
• Observe all governing codes and ordinances.  
• Be sure to leave these instructions with the  
consumer.  
Anchor Sleeves (6)  
Lag Bolts (6)  
NOTE  
(For Anti-Tip Bracket Mounted  
on Concrete Floors and Walls)  
Keep these instructions with your owner’s manual  
for future reference.  
• As when using any appliance generating heat, there  
are certain safety precautions you should follow.  
• Be sure your range is installed and grounded  
properly by a qualified installer or service technician.  
• Make sure the wall coverings around the range can  
withstand the heat generated by the range.  
• To eliminate the need to reach over the surface  
elements, cabinet storage space above the elements  
should be avoided.  
PARTS NOT PROVIDED  
(UL Approved 40 or 50 AMP)  
Strain Relief  
(For Conduit  
Installations Only)  
4-Wire Cord OR 3-Wire Cord  
PREPARE TO INSTALL THE RANGE  
6
INSTALLATION DRAWINGS (LDE Series only)  
NOTE  
WARNING  
SAVE FOR THE USE OF THE LOCAL ELECTRICAL  
INSPECTOR.  
You should use two or more people to move and  
install range. (Excessive Weight Hazard)  
- Failure to do so can result in back or other injury.  
You never pull or push any handles of upper &  
lower door to move and install range.  
- Failure to do so can result in serious damage to  
the door of the range.  
CLEARANCES AND DIMENSIONS (Figure 1)  
To install range refer to the following Figure 1.  
For installation in CANADA, a Free-standing range is  
not to be installed closer than 15/32 (12mm) from any  
adjacent surface.  
CAUTION  
CAUTION  
You should make sure that the wall covering,  
countertop and cabinets around the range can  
withstand the heat (up to 194°F) generated by  
the range.  
• Cabinet storage space located above the  
surface units should be avoided.  
You should install a range hood that projects  
horizontally a minimum of 5 inches beyond  
the bottom of the cabinets.  
- Discoloration, delamination or melting may  
occur.  
If cabinet Storage is to be provided.  
- This range has been designed to comply  
with the maximum allowable wood cabinet  
temperatures of 194°F.  
- The risk of burns or fire by reaching over the  
heated surface elements can be reduced.  
Cabinet  
opening  
Wall  
Center  
15”(38cm)  
11”(28cm)  
Cabinet  
6”  
2.5”(6.3cm)  
(15.2cm)  
5”  
4”  
6”  
(13cm)  
9”  
(23cm)  
(10cm)  
(15.2cm)  
2.5”  
4”  
9”  
(23cm)  
(6.3cm)  
(10cm)  
A = 30”(76.2 cm) For U.S.A  
= 30”(76.2 cm) ~ 31”(78.7 cm) For CANADA  
FIGURE 2  
FIGURE 1  
MINIMUM DIMENSIONS (Figure 2)  
* 30”(76.2 cm) minimum clearance between the top of the cooking surface and the bottom of an unprotected wood  
or metal cabinet; or 24”(60.9 cm) minimum when bottom of wood or metal cabinet is protected by not less than  
1/4”(6.4 cm) flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015”(0.381 mm) stainless  
steel, 0.024”(0.610 mm) aluminum or 0.020”(0.508 mm) copper.  
** 15”(38.1 cm) minimum between countertop and adjacent cabinet bottom.  
ELECTRICAL CONNECTIONS  
7
ELECTRICAL CONNECTION  
REQUIREMENTS  
This appliance must be installed and grounded on a  
branch circuit by a qualified technician in accordance  
with the National Electrical code ANSI/NFPA NO. 70 -  
latest edition.  
CONNECT RANGE CORD  
WARNING  
You never remove the protection cover covering  
the rear of lower oven.  
-
Failure to do so can result in serious damage to power  
cord. The damage causes serious burns and electric shock.  
All wiring should conform to Local and NEC. This  
range requires a single-phase, 3 wire, A.C 120/208V or  
120/240V 60Hz electrical system. Use only a 3-conductor  
or a 4-conductor UL-listed range cord with closed-loop  
terminals, open-end spade lugs with upturned ends  
or similar termination. DO NOT install the power cord  
without a strain relief.  
The Rear Access cover must be removed. Loosen the  
three screws with a screwdriver. The terminal block will  
then be accessible.  
Terminal block  
Access cover  
A range cord rated at 40 amps with 120/240 minimum  
volt range is required. If a 50 amp range cord is used, it  
Protection cover  
Cord/Conduit  
Access  
3
/
connection  
should be marked for use with 1 8diameter connection  
Rear of lower oven  
plate  
cover  
openings.  
This appliance may be connected by means of conduit  
or power cord. If conduit is being used, go to page 8  
for 3 wire conduit connections or page 9 for 4 wire  
conduit connections.  
FIGURE 4  
The Cord/Conduit connection plate is used for the  
installation of power cord or conduit. For power cord,  
install it with the connection plate as INSTALLED. For  
conduit, remove the connection plate located below the  
rear of the drawer body and use the conduit hole (11/8”)  
instead of power cord hole (13/8”). (Refer to Figure 5 and 6.)  
WARNING  
• New branch-circuit installations (1996 NEC)  
for mobile homes, recreational vehicles, and  
installations where local codes do not allow  
grounding through the neutral wire require  
a 4-conductor UL listed range cord or 4 wire  
conduit connection.  
11/8"  
(2.8cm)  
13/8"  
(Cord)  
• Power supply cord and plug should not be  
modified. If it will not fit the outlet, have a  
proper outlet Installed by a qualified electrician.  
• Using an extension cord to connect the power is  
prohibited. The way to connect the power cord  
and plug directly is strongly recommended.  
• Electrical ground is required on this appliance.  
You should make sure that the power cord is  
not pinched by the range or heavy objects.  
- Failure to do so can result in serious burns or  
electrical shock.  
11/8"  
13/8"  
(Conduit)  
(3.5cm)  
Remove the Conduit connection plate  
FIGURE 5  
Cord/Conduit  
connection  
plate  
Strain relief  
Conduit  
Ring  
Specified power-supply-cord kit rating  
Conduit  
Range rating, watts  
Specified rating Diameter (inches) of Range  
Assemble the  
strain relief hole  
of power-  
supply- cord kit,  
amperes  
connection Opening  
Power cord Conduit  
Body  
120/240 volts 120/208 volts  
3-wire  
3-wire  
8,750 - 16,500 7,801 - 12,500  
16,501 - 22,500 12,501 - 18,500  
40 or 50A  
50  
1 3/8”  
1 3/4”  
1 1/8”  
1 3/8”  
3, 4 - Wire electrical wall Receptacle  
Cord Strain  
relief  
4 Wire receptacle (14-50R)  
Reinstall the Cord/Conduit connection plate  
3 Wire receptacle (10-50R)  
FIGURE 6  
FIGURE 3  
ELECTRICAL CONNECTIONS  
8
3-WIRE CONNECTION WITH  
A POWER SUPPLY CORD  
WARNING  
• The middle (neutral or ground) wire of a 3  
wire power cord or a 3 wire conduit has to  
be connected to the middle post of the main  
terminal block. The remaining two wires of the  
power cord or conduit have to be connected  
to the outside posts of the main terminal  
connection block.  
Cord strain relief  
Conduit  
connection  
plate  
- Failure to do so can result in electrical shock,  
severe personal injury or death.  
Separate Strain Relief  
before installation  
Install the power cord as follows:  
For power cord installations, Hook the strain relief over  
the power cord hole (13/8”) located below the rear of  
lower oven. Insert the power cord through the strain  
relief and tighten it. (Refer to Figure 7.)  
Assemble the strain relief  
to the 1 3/8” opening in  
Conduit connection plate  
Power cord  
FIGURE 7  
DO NOT install the power cord without a strain relief.  
3-wire connection  
1. Remove the lower 3 screws from the terminal block  
and retain them. (Refer to Figure 8.)  
Black White Red  
Terminal  
block  
2. Insert the 3 screws through each power cord terminal  
ring and into the lower terminals of the terminal block.  
Make sure that the center wire (white/neutral) is  
connected to the center lower position of the terminal  
block.  
3. Tighten 3 screws securely into the terminal block.  
Do not remove the ground strap connections.  
4. Go to page 11.  
Conduit  
connection plate  
FIGURE 8  
ELECTRICAL CONNECTIONS  
9
4-WIRE CONNECTION WITH  
A POWER SUPPLY CORD  
3-WIRE CONNECTION: CONDUIT  
Install the conduit as follows:  
Remove the Conduit connection plate from the rear of  
lower oven and rotate it as shown in Figure 5. The  
conduit hole (11/8”) must be used.  
WARNING  
• Only a 4-conductor power-supply cord kit rated  
120/240 volts, 50 amperes and marked for use  
with ranges with closedloop connectors or  
open-end spade lugs with upturned ends shall  
be used. The middle (neutral) wire of the power  
cord or 4-wire conduit has to be connected to  
the middle post of the main terminal block. The  
other two wires of the power cord or conduit  
have to be connected to the outside posts of  
the main terminal connection block. The 4th  
ground wire must be connected to the frame of  
the range with the ground screw.  
First, prepare the conduit wires as shown in Figure 10.  
3 wire  
4 wire  
Conduit  
connection  
plate  
Ground  
wire  
or  
FIGURE 10  
- Failure to do so can result in electrical shock,  
severe personal injury or death.  
Second, install conduit as shown in Figure 6.  
For conduit installations, after purchasing a strain relief,  
insert it in the conduit hole (11/8”). Then install the  
conduit through the body of strain relief and fasten the  
strain relief with its ring. Reinstall the bracket.  
Follow the instructions under “CONNECT RANGE CORD”  
on page 7 to correctly install the strain relief.  
1. Remove the lower 3 screws from the terminal block  
and retain them. (Refer to Figure 9.)  
Remove the ground screw and retain it.  
For conduit connections :  
If the wire in the conduit is copper it must be 8 or 10  
AWG wiring.  
2. Remove ground strap and discard as shown in  
Figure 9.  
Do not discard any screws.  
If the wire in the conduit is aluminum it must be 6 or 8  
AWG wiring.  
1. Loosen the lower 3 screws from the terminal block.  
(Refer to Figure 11.)  
2. Insert the bare wire (white/neutral) end through the  
center terminal block opening.  
Do not remove ground strap connections.  
3. Insert the two side bare wire ends into the lower left  
and the lower right terminal block opening.  
Tighten the 3 screws securely into the terminal block.  
(approximately 35 - 50 IN-LB)  
3. Insert the ground screw into the power cord ground  
wire terminal ring and secure it to the range frame.  
4. Insert the 3 screws through each power cord terminal  
ring and into the lower terminals of the terminal block.  
Make sure that the center wire (white/neutral) is  
connected to the center lower position of the terminal  
block.  
Tighten 3 screws securely into the terminal block.  
4. Go to page 11.  
5. Go to page 11.  
3-wire connection  
4-wire connection  
Black White Red  
Black White Red  
Terminal  
Terminal  
block  
block  
Ground  
strap  
Wire ends  
Remove ground  
strap and discard  
Conduit  
connection plate  
Conduit  
connection plate  
Ground screw  
FIGURE 11  
FIGURE 9  
ELECTRICAL CONNECTIONS  
10  
4-WIRE CONNECTION: CONDUIT  
1. Follow the instructions under “Install the conduit as  
followson page 9 to correctly install the strain relief.  
DO NOT install the conduit without a strain relief.  
2. Loosen the 2 lower left and right screws from the  
terminal block. (Refer to Figure 12.)  
4-wire connection  
Black White Red  
Terminal  
block  
Ground  
strap  
Remove the lower 2 center screws.  
3. Remove ground strap and discard as shown in  
Figure 12.  
Do not discard any screws.  
4. Attach the ground bare wire end to range frame and  
secure it in place with the ground screw (Refer to  
figure 12.)  
Wire  
ends  
Remove  
ground  
strap and  
discard  
Conduit  
connection plate  
5. Insert the bare wire (white/neutral) end through the  
center terminal block opening.  
6. Insert the two side bare wire ends into the left and the  
right terminal block opening.  
Tighten the 3 screws securely into the terminal block.  
(approximately 35 - 50 IN-LB)  
7. Go to page 11.  
Ground  
Wire  
Ground  
Screw  
FIGURE 12  
INSTALL THE RANGE  
11  
Replace the access cover on the back of the range. To  
replace the wire cover, insert the two tabs into the  
openings located below the opening and tighten the  
three screws.  
Lower  
range  
Access cover  
Leg  
leveler  
Raise  
range  
Use a level to check your adjustments. Place the level  
diagonally on the oven rack, and check each direction  
for level.  
ANTI-TIP DEVICE INSTALLATION  
First check direction .  
level  
After check direction .  
WARNING  
Tip - Over Hazard  
If the level doesn’t show  
level on the rack, adjust  
the leveling legs with a  
wrench.  
A child or adult can tip the range and be  
killed. Verify the anti-tip bracket have been  
installed. Ensure the anti-tip bracket is  
enganged when the range is moved.  
Do not operate the range without the anti-  
tip bracket in place. Failure to follow these  
instructions can result in death or serious  
burns to children and adults.  
FINAL INSTALLATION  
• Move range close enough to the opening to plug into  
the receptacle.  
To check visually that leveling leg is inserted  
into bracket, grasp the top rear edge of the  
range and carefully attempt to tilt it forward.  
• Slide range into position insuring that the left back leg  
slides under the anti-tip bracket. Range should sit flush  
against the back wall when properly installed.  
Leveling  
leg  
bracket  
Anti-tip  
bracket  
Screw must  
enter wood  
or concrete  
Wall plate  
• Carefully attempt to tip range forward to insure that  
the anti-tip bracket is engaged properly. If properly  
installed, the anti-bracket will prevent the range from  
being tipped. If the range can be tipped, reinstall the  
range until the bracket is properly installed and the  
range will not tip forward.  
1. Locate the bracket using the template  
An Anti-tip bracket is packaged with template. The  
instructions include necessary information to  
complete the installation.  
• Turn on electrical power. Check the range for proper  
operation as described in owner’s manual.  
Read and follow range installation instruction sheet  
(template).  
2. Level the range  
Level the range by adjusting the leveling legs with a  
wrench.  

Sony Rm X33 User Manual
Schumacher Se 2152ma User Manual
Philips Lr14eb4a User Manual
NEC NEAX 2400 User Manual
Minolta Bizhub C353 User Manual
LG LG K500N User Manual
KENWOOD KMR M312BT User Manual
EMERSON QUIET KOOL EARC22RE2 User Manual
Dewalt 20v Drill User Manual
ACER ASPIRE 3 A315 51 User Manual