USER MANUAL
Smart Ultrasonic Cool Mist Humidifier
Model: Classic 200S
Questions or Concerns?
Please contact us Mon–Fri, 9:00 am–5:00 pm PST/PDT
READ AND SAVE THESE
INSTRUCTIONS
SAFETY INFORMATION
To reduce the risk of fire, electric shock, or other injury, follow all instructions and
safety guidelines.
General Safety
•
•
Only use the humidifier as described in
•
•
Do not use other items as replacement
this manual.
parts for this product.
Place the humidifier and cord so that it
will not be knocked over. Do not place
near large pieces of furniture or in high-
traffic areas.
Do not cover the nozzles while the
humidifier is on. Doing so may damage
the humidifier.
•
•
•
Remove the water tank from the base
before moving the humidifier.
•
When not in use, turn the humidifier
off and disconnect from power by
removing the plug from the outlet.
Do not immerse the humidifier base,
power cord, or plug in water.
•
•
•
•
Do not use the humidifier in wet
If the humidifier is damaged or is not
functioning properly, stop using it and
contact Customer Support immediately
environments.
Keep the humidifier out of reach from
children.
Do not open the base or remove the
•
Not for commercial use.
water level sensor for self-servicing.
Household use only.
Always unplug your humidifier from
the power outlet before cleaning your
humidifier or detaching the water tank
from the humidifier base.
Caution: Risk of Leaks and
Electric Shock
•
•
•
•
Always make sure to place the
humidifier on a flat, level surface before
operation.
•
Do not add essential oils,
supplemental water treatment
liquids, or water filters into the
water tank or base chamber. This
will damage the humidifier and
cause leaks. Only add essential
oils to the aroma pad.
Only fill the water tank with clean water.
Never fill the water tank with any other
liquids.
Do not place the humidifier near
sources of heat, such as stovetops,
ovens, or radiators.
Do not place the humidifier directly on
floors, carpets, or rugs.
3
SAFETY INFORMATION (CONT.)
Plug & Cord
•
•
Ensure that the plug fits properly into
a polarized socket.
Do not handle the power cord or
plug with wet hands. Keep the plug
and power cord away from liquids.
•
Your humidifier has a polarized plug
(one prong is wider than the other),
which fits into a polarized outlet only
one way. This is a safety feature to
reduce the risk of electric shock. If
the plug does not fit, reverse the
plug. If it still does not fit, do not use
the plug in that outlet. Do not bypass
this safety feature.
4
GETTING TO KNOW YOUR SMART HUMIDIFIER
A. Nozzles
J. Control Button
K. Insulation Ring
L. Transducer
M. Float Housing
N. Float
S. Power Cord
B. Nozzle Cover
C. Water Tank Handle
D. Mist Outlet
T. Water Tank Cap
U. Silicone Sealing Ring
V. Water Valve
E. Water Tank
W. Noise Silencer
X. Humidity Sensor
Y. Aroma Pad
F. Cleaning Brush
G. Cleaning Brush Storage
H. Base
O. Mist Tube
P. Water Tank Windows
Q. Air Outlet
Z. Aroma Box
I. WiFi® Button
R. Base Chamber
AA. Air Inlet
T
A
U
B
C
V
M
N
W
D
O
P
E
Water tank, upside down
X
Q
R
G
H
Y
Z
I
AA
J
Back
S
F
K L
5
Filling & Refilling
GETTING STARTED
1. Remove the nozzle cover from the
water tank. Use the handle to lift the
water tank from the base. [Figure 1.3]
1. Remove all packaging.
2. Choose a hard, flat location for the
humidifier at least 12 in / 30 cm away
from any walls. The surface must be
water-resistant. [Figure 1.1]
12 in /
30 cm
12 in /
30 cm
Figure 1.1
Figure 1.3
3. Mist should be directed away
from walls, furniture, bedding, and
appliances. [Figure 1.2]
2. Flip over the water tank and remove
the water tank cap by twisting it
counterclockwise. [Figure 1.4]
Figure 1.2
Figure 1.4
6
Filling & Refilling (cont.)
CAUTION
3. Fill the tank with room-temperature
water. [Figure 1.5] Do not fill with hot
water.
•
Do not add water directly into the base
chamber. [Figure 1.6]
Note: We recommend using purified or distilled
water to fill the tank.
Figure 1.6
•
•
Do not add water through the mist tube.
Do not add essential oils into the
humidifier. [Figure 1.7] Only add
essential oils to the aroma pad.
[Figure 1.8]
Figure 1.5
4. Replace the water tank cap and align
the arrow with the lock. [Figure 1.9]
Figure 1.7
Figure 1.8
•
Do not use water treatment liquids, or
third-party water filters in this humidifier.
Figure 1.9
7
Filling & Refilling (cont.)
VESYNC APP SETUP
5. Place the tank back on the base and
replace the nozzle cover onto the water
tank. [Figure 1.10]
Note: Due to ongoing updates and improvements,
the VeSync app may be slightly different than
shown in the manual. In case of any differences,
follow the in-app instructions.
1. To download the VeSync app, scan
the QR code or search “VeSync” in the
Apple App Store® or Google Play Store.
[Figure 2.1]
Note: For Android™ users, choose “Allow” to use
VeSync.
2. Open the VeSync app. If you already
have an account, tap Log In. To create a
new account, tap Sign Up.
Note: You must create your own VeSync account
to use third-party services and products. These
will not work with a guest account. With a VeSync
account, you can also allow your family and
friends to control your smart humidifier.
3. Follow the in-app instructions to set up
your smart humidifier.
Note: You can use the VeSync app to connect
your smart humidifier to Amazon Alexa or Google
Assistant™. Follow the in-app instructions to
connect VeSync to your voice assistant.
Figure 1.10
GET IT ON
Available on the
Google Play
App Store
Figure 2.1
8
USING YOUR SMART HUMIDIFIER
Note: Using the VeSync app allows you to control
your smart humidifier remotely and access additional
1. Plug in the humidifier.
2. Tap
to turn your humidifier on.
Tap repeatedly to cycle through mist
settings: Auto Mode, Low, Medium,
High, and Off. [Figure 3.1]
Note: For more information on Auto Mode, see
3. Rotate the nozzles to adjust the
Figure 3.1
direction of the mist. [Figure 3.2]
4. When your room has reached your
preferred humidity level, turn the
humidifier to a lower setting or turn it off.
A healthy humidity level is between 40%
and 50%. [Figure 3.3]
5. Press and hold
for 2 seconds to turn
your humidifier off.
Note:
•
If there is no water in the tank or the tank is
removed, the humidifier will stop misting,
will turn red, and the fan will turn off after 5
seconds.
•
When the tank is empty or removed,
or
you can tap
humidifier off.
to turn the
Figure 3.2
•
•
Refill the tank and properly place it on
the base to use your humidifier.
To restart the humidifier, tap
as normal. You can also turn the
humidifier back on in the app, which
will remember your previous mist level
setting.
•
To reset the humidifier, press and hold
for
15 seconds. This will restore the humidifier’s
default settings and disconnect it from the
VeSync app.
Figure 3.3
9
Button Color
Button
Button Color
Green
Function
Low mist setting is selected
Medium mist setting is selected
High mist setting is selected
Auto Mode is selected
Cyan
Blue
White
Red
No water in tank or tank not on base
Humidifier is off
Off
Display lights have been turned off
Humidifier is in WiFi pairing mode
Humidifier has been paired with WiFi
Humidifier is off
White (Flashing)
White
Off
Display lights have been turned off
Humidifier is not connected to WiFi
Note:
•
Auto Mode
Tap
to turn off the indicator lights.
to configure your smart
•
Press and hold
Auto Mode uses the humidifier’s sensor to
automatically adjust the mist level (or turn it
off) to maintain a comfortable and healthy
level of humidity.
humidifier. See the VeSync in-app instructions
for more information.
•
Auto Mode will automatically adjust
the mist level to maintain 45% relative
humidity. You can change the target
humidity level in the VeSync app.
•
•
By default, Auto Mode will keep running
on Low mist level when the target
humidity level is reached.
In the VeSync app, you can change the
Auto Mode settings to include Automatic
Stop. This will cause the humidifier to
stop misting when the target humidity
level is reached. If the humidity drops
below the target humidity level, then the
humidifier will begin misting again.
10
VeSync App Functions
The VeSync app allows you to access
additional smart functions, including those
listed below.
Remote Control
•
•
•
Cycle through mist levels and turn on
Auto Mode from your phone.
Turn display lights on/off from your
phone.
Customize Auto Mode settings like target
humidity and auto-off.
Monitor Humidity Levels
•
Check current humidity levels in the
humidifier’s environment.
Set Timers and Schedules
•
Program individual timers or create a
schedule for your smart humidifier.
Third-Party Voice Control
•
Compatible with Amazon Alexa and
Google Assistant for voice commands.
Note: The VeSync app is continually updated and
app features will expand.
11
Important Tips
Your humidifier must have the correct level
of water in the base chamber to work
properly. If there is too much water in the
base chamber, the humidifier cannot create
mist.
•
Never pour water directly into the
base chamber. Only add water to the
water tank. [Figure 3.4] The humidifier
will automatically release the correct
amount of water into the base chamber.
Figure 3.4
•
Avoid moving or shaking the humidifier.
[Figure 3.5] This may cause the water
tank to release too much water into the
base chamber.
•
•
Before moving the humidifier, turn it off,
unplug it, and remove the water tank.
If your humidifier doesn’t produce mist
correctly, check the max water line to
see if there is too much water in the
base chamber. Pour out extra water if
water is over the max line. [Figure 3.6]
Note: The max water line is only for this purpose.
Do not pour water into the base chamber.
Figure 3.5
Figure 3.6
12
Using the Aroma Box
Preventing Leaks
Your humidifier can be used for
aromatherapy.
The water tank may leak if not placed
properly.
1. Push the aroma box at the back of the
•
Make sure the silicone sealing ring
around the water tank cap is secured at
all times.
base and pull it out. [Figure 3.7]
•
Twist and secure the cap tightly onto
the water tank. Make sure the arrow is
aligned with the lock. [Figure 3.9]
Figure 3.7
2. Put 2–3 drops of essential oil on the
aroma pad. [Figure 3.8]
Figure 3.9
Note: A small gap between the cap and the tank
is normal.
•
Wipe any excess water off the top and
bottom of the base.
Figure 3.8
•
•
Do not shake the humidifier.
3. Place the aroma box into the humidifier.
Make sure to place the humidifier on a flat,
level surface.
4. Turn on the humidifier. The humidifier
will automatically diffuse aroma when
used.
Note:
•
Do not add essential oils, water treatment
liquids, or third-party water filters into the
water tank or base chamber. Only add
essential oils to the aroma pad.
•
•
The aroma pads can be cleaned and reused
after diffusing essential oils (see Cleaning the
Aroma Pad, page 17).
The aroma is intended to be light. This
humidifier is not an aroma diffuser.
13
CARE & MAINTENANCE
Note:
3. Remove the water tank from the base.
Pour out any water from the tank and
base chamber. [Figure 4.2]
•
•
•
•
All maintenance should be done on a water-
resistant surface, such as a kitchen counter.
Change the water daily to avoid bacteria
growth.
Use a tissue or cloth to clean the nozzles
regularly.
If not using the humidifier for 1 week or longer,
do not leave water inside. Clean and dry the
humidifier instead.
Cleaning
You should clean your humidifier every
week, and when you’re ready to store it.
Figure 4.2
Note:
4. Rinse the tank and base chamber with
room temperature water. [Figure 4.3]
•
Never immerse the base in water or liquid.
Do not place any part of the humidifier in a
dishwasher.
•
Do not use detergents to clean the humidifier.
1. Unplug the humidifier.
2. Remove and rinse the nozzle cover.
[Figure 4.1]
Figure 4.3
Figure 4.1
14
Cleaning (cont.)
5. To descale the humidifier:
c. Place the tank on the base and
soak for 15–20 minutes. Vinegar
will drain into the base chamber
and loosen scale (mineral buildup)
in the tank and in the base
a. Fill the tank with 3 US cups / 710
mL of distilled white vinegar.
[Figure 4.4]
chamber (including the transducer
and float). [Figure 4.6]
Figure 4.4
Figure 4.6
b. Replace the tank cap and swish
the vinegar around the tank.
[Figure 4.5]
d. Remove the tank and pour out any
vinegar. [Figure 4.7]
Figure 4.7
Figure 4.5
15
Cleaning (cont.)
e. Flip the tank over and remove the
tank cap and noise silencer. To
remove the noise silencer, press
the release tab and gently pull
away from the humidifier.
g. Use a soft cloth and the included
cleaning brush to remove scale.
[Figure 4.10]
[Figure 4.8]
Figure 4.10
Figure 4.8
h. Rinse all parts until any vinegar
smell is completely gone.
[Figure 4.11]
f. Place the tank cap and noise
silencer in a small container and
fill with enough vinegar to cover
them. Soak for 15–20 minutes.
[Figure 4.9]
Figure 4.9
Figure 4.11
6. Dry all parts with a cloth. Make sure
all parts are completely dry before
reassembling or storing.
Note: Brush can be stored in the brush storage
slots in the base.
16
Cleaning the Aroma Pad
1. Press the aroma box to release it from
3. Dry with a clean cloth and place it back
the base, and pull it out. [Figure 4.12]
into the aroma box. [Figure 4.14]
Figure 4.12
Figure 4.14
2. Remove the aroma pad and rinse under
Note: Do not pour liquid cleaners or detergents
into the aroma pad or box.
warm, running water. [Figure 4.13]
Figure 4.13
17
Reassembling
1. Flip the water tank over and replace the
3. Store the brush in the brush storage
noise silencer on the tank. [Figure 4.15]
slots in the base. [Figure 4.17]
Figure 4.17
Figure 4.15
4. Place the tank properly on the base and
replace the nozzle cover onto the water
tank. [Figure 4.18]
2. Refill the tank, if necessary. Replace the
water tank cap by firmly twisting it back
in place, aligning the arrow with the
lock. [Figure 4.16]
Figure 4.18
Figure 4.16
Storing
Follow the cleaning instructions (see page
before storing. Store in a cool, dry location.
18
TROUBLESHOOTING
Problem
Possible Solution
Plug in the humidifier and turn it on.
Add purified or distilled water to the water tank.
Turn the mist level to a higher setting.
Fill the water tank.
Humidifier doesn’t turn on.
There may be too much water in the base chamber. Empty
the base chamber. Refill the water tank (not the base
chamber) and place the water tank properly onto the base.
Make sure the air inlet on the bottom of the base is not
blocked. The humidifier should not be set on carpet or other
surfaces that may block the air inlet.
Little or no mist comes out.
Make sure the nozzles are not blocked or clogged.
Make sure the humidifier is on a level surface.
The water temperature may be too low. Turn the mist level to
the highest setting and let the humidifier run for a while, then
adjust to the desired setting.
If the water tank or base was washed with detergent, rinse
thoroughly with clean water to remove any detergent.
The humidifier uses up water based on the environmental
temperature and humidity. If your environment is cold and/or
dry, the humidifier will run out of water faster.
Humidifier uses water too
quickly.
If the humidifier is new, remove and rinse the water tank cap,
and place the water tank in a cool, dry place for 12 hours.
Humidifier produces an
unusual smell.
If essential oils were placed on the aroma pad, rinse the pad
under clean water and allow it to dry.
Clean the water tank and base chamber (see Care &
Maintenance, page 14).
19
TROUBLESHOOTING (CONT.)
Problem
Possible Solution
Make sure the water tank is properly in place (see Getting
Started, page 6).
Set mist level to a lower setting.
Humidifier makes a loud or
unusual noise.
Empty the base chamber. Refill the water tank (not the base
chamber) and place the water tank properly onto the base.
The humidifier may be malfunctioning. Stop using the
We recommend using purified or distilled water to fill the
humidifier. Avoid using water with high mineral content.
White dust appears around
the humidifier.
Make sure the silicone sealing ring around the water tank
cap is secure and tighten the water tank cap.
Water leaks from the
humidifier.
Check the water tank for leaks. If there are leaks, contact
Condensation forms
around humidifier or
windows.
Humidity may be too high. Turn down the mist level, turn off
the humidifier, or open a door or window to the room.
Mold grows inside the
humidifier.
Clean the water tank and inner chamber regularly
Fill the water tank.
is red.
Place the water tank properly on the base.
Essential oil has little or no
smell.
Add more essential oil. For best results, use pure essential
oil.
20
VESYNC APP TROUBLESHOOTING
Why isn’t my humidifier connecting to the
VeSync app?
The VeSync app is displaying an incorrect
humidity percentage while the humidifier
is turned on.
•
Make sure your phone has Bluetooth®
turned on and is not currently connected
to another Bluetooth device.
•
The room may be larger than the
humidifier’s effective range. Move to a
room smaller than 376 ft² / 35 m².
Moisture may have built up inside the
humidity sensor. Turn off the humidifier
and allow the sensor to air dry. Make sure
the nozzles are facing away from the
sensor so that mist does not settle on the
sensor, which is located on the back of
•
During the setup process, you must be
on a secure 2.4 GHz WiFi® network.
Confirm that the network is working
correctly.
•
•
•
•
Make sure the WiFi password you
entered is correct.
Make sure your humidifier and phone are
within 30 ft / 10 m of each other.
Reset the humidifier by pressing and
holding for 15 seconds. Then try
connecting again.
My humidifier is offline.
•
Make sure the humidifier is plugged in.
The humidifier may appear to be offline
if it is unplugged, or if the outlet does not
have power.
•
•
Refresh the VeSync menu by swiping
down on the screen.
Make sure your router is connected to
the internet and your phone’s network
connection is working.
•
Reset the humidifier using one of these
options:
a. Delete the humidifier from the
VeSync app. Swipe left (iOS®) or
press and hold (Android), then tap
Delete. Then reconfigure your
humidifier with the VeSync app.
b. Press and hold
for 15 seconds.
Then reconfigure your humidifier
with the VeSync app.
Note: Power outages, internet outages, or
changing WiFi routers may cause your humidifier
to go offline.
21
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one of the following
measures:
•
•
Reorient or relocate the receiving antenna.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•
•
Increase the separation between the equipment and receiver.
Consult the dealer or an experienced radio/TV technician for help.
FCC RADIATION EXPOSURE STATEMENT
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. End users must follow the specific operating instructions for satisfying RF exposure
compliance. To maintain compliance with FCC RF exposure compliance requirements, please
follow operation instructions as documented in this manual. This transmitter must not be co-
located or operating in conjunction with any other antenna or transmitter. This equipment should
be installed and operated with a minimum distance of 20 cm between the radiator and your
body. The availability of some specific channels and/or operational frequency bands are country
dependent and are firmware programmed at the factory to match the intended destination. The
firmware setting is not accessible by the end user.
22
WARRANTY INFORMATION
Arovast will not be liable for indirect, incidental,
or consequential damages in connection with the
use of the product covered by this warranty.
Smart Ultrasonic Cool Mist
Humidifier
Product
Model Classic 200S
Date of Purchase
Order ID
This warranty extends only to the original
consumer purchaser of the product and is not
transferable to any subsequent owner of the
product regardless of whether the product is
transferred during the specified term of the
warranty.
This warranty does not extend to products
purchased from unauthorized sellers. Arovast’s
warranty extends only to products purchased from
authorized sellers that are subject to Arovast’s
quality controls and have agreed to follow its
quality controls.
Terms & Policy
Arovast Corporation (“Arovast”) warrants this
product to the original purchaser to be free from
defects in material and workmanship, under
normal use and conditions, for a period of one
year from the date of original purchase.
All implied warranties are limited to the period of
this limited warranty.
This warranty gives you specific legal rights
and you may also have other rights which
vary from state to state. Some states do not
allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or
exclusion may not apply to you.
Arovast agrees, at our option during the
warranty period, to repair any defect in material
or workmanship or furnish an equal product in
exchange without charge, subject to verification
of the defect or malfunction and proof of the date
of purchase.
If you discover that your product is defective
within the specified warranty period, please
contact Customer Support via
There is no other express warranty. This
warranty does not apply:
product before contacting us. Once our Customer
Support Team has approved your request, please
return the product with a copy of the invoice and
order ID.
•
•
If the product has been modified from its
original condition;
If the product has not been used in
accordance with directions and instructions
in the user manual;
•
•
To damages or defects caused by accident,
abuse, misuse or improper or inadequate
maintenance;
To damages or defects caused by service
or repair of the product performed by an
unauthorized service provider or by anyone
other than Arovast;
Extend Your Warranty by 1 Year
Register your product within 14 days of purchase
1-year warranty by an additional year.
This warranty is made by:
•
•
To damages or defects occurring during
commercial use, rental use, or any use for
which the product is not intended;
To damages or defects exceeding the cost
of the product.
Arovast Corporation
1202 N. Miller St. Suite A
Anaheim, CA 93806
23
CUSTOMER SUPPORT
If you have any questions or concerns
about your new product, please contact our
helpful Customer Support Team.
Arovast Corporation
1202 N. Miller St., Suite A
Anaheim, CA 92806
Email: [email protected]
Toll-Free: (888) 726-8520
Support Hours
Mon–Fri, 9:00 am–5:00 pm PST/PDT
*Please have your order invoice and order ID
ready before contacting Customer Support.
ATTRIBUTIONS
Apple App Store is a trademark of Apple Inc.
Google, Android, and Google Play are trademarks of Google LLC.
Wi-Fi® is a registered trademark of Wi-Fi Alliance®.
Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates.
iOS is a registered trademark of Cisco Systems, Inc. and/or its affiliates in the United States
and certain other countries.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc.
and any use of such marks by Arovast Corporation is under license.
24
NOTES
NOTES
Connect with us @LevoitLifestyle
levoit.com
JJ080620AL-M1_0620Classic200S
|