Troubleshooting  
Condition  
Probable Cause  
Pump does not run when water is added to  
the sink.  
-Check that pump is plugged in.  
-Check power to outlet or circuit.  
-Pump plugged into a switched outlet.  
-Fuse/breaker blown or tripped.  
-Foreign object lodged in pump chamber.  
-Sink drain screen clogged.  
Pump runs but does not empty sink.  
-Sink stopper inserted in drain.  
-Clogged check valve.  
-Clogged discharge line.  
-Shut-off (balancing) valve closed or not  
adjusted properly.  
-“System” lift too high or piping run too long.  
-Check valve or back flow preventer not  
installed in discharge line.  
-Dirt in check valve is allowing water to flow  
back into pump from drain line.  
-Balancing / shut-off valve not installed in drain  
line.  
MODEL LTA-1 (802210)  
AUTOMATIC SINK DRAIN PUMP  
INSTALLATION OPERATION MAINTENANCE  
READ ALL INSTRUCTIONS  
Pump turns on and off (“cycles”) when no  
water is in the sink.  
BEFORE STARTING INSTALLATION  
General Information  
Pump turns on and off (“cycles”) rapidly  
when sink is full or at maximum water flow.  
The HARTELL LTA-1 model pump is a completely self-contained unit  
designed to remove wastewater from sinks when a traditional gravity drain  
line is not available. Popular applications include; wet bar sinks, kitchenettes,  
utility sinks, and laundry tray sinks.  
-Balancing valve not adjusted properly.  
(Pump will cycle with faucets partially on. This is normal and will not harm pump.)  
Lightweight and compact, the LTA pump mounts directly to the drain  
tailpiece of your sink, eliminating all traps and inlet piping.  
Service and Maintenance  
The LTA design does not require any connection to the main stack vent1  
which is common with other types of drain pump systems.  
The LTA pump is designed to be virtually maintenance free when used in  
accordance with the installation guidelines specified in these instructions.  
Installation and preservation of an inlet screen will prevent excessive  
accumulation of material in the pump chamber and possible obstruction of the  
impeller by foreign objects such as stones, string, buttons, etc.  
Before returning the unit for replacement, the pump housing should be removed  
and the impeller chamber checked for obstructions.  
The LTA pump’s rugged construction, automatic operation, and ease of  
installation provides the best value in a drain pump that will provide many  
years of trouble free service.  
Proper installation practices will ensure virtually maintenance free operation,  
and extend the life of your pump.  
Installation Note: All pumping and piping systems will fail at some point due  
to a variety of reasons including power failures, foreign objects, neglect, or  
“old age”. Proper safeguards, and precautions such as alarms, safety  
switches, drain pans, etc. should be installed with any system when system  
failure will result in damages to finished living spaces. It is the responsibility  
of the installer to make appropriate provisions for system failure consistent  
with each specific installation.  
To check impeller, Unplug pump and remove from  
sink. Remove four (4) ¼” hex head screws from  
the “fins” of the housing as shown in figure 2.  
Separate housing from motor base plate and  
inspect for obstructions. After clearing any debris,  
replace housing on the base plate making sure  
that the rubber “o” ring is in place around the  
HEX HEAD  
HOUSING  
SCREWS  
FIGURE 2  
“step” in the base plate. Re-install pump following all instructions.  
! WARNING  
Risk of electrical shock. This pump is supplied with a  
Warranty  
grounding type cord and plug. Do not modify cord or plug. Plug pump  
into a properly grounded, grounding type, GFCI receptacle, following  
all local codes.  
HARTELL products are warranted to be free from manufacturing defects, for a period of twelve (12)  
months past the date of installation. Within the warranty period, HARTELL will replace or repair any  
products determined to be defective by the Factory or an authorized Representative. Purchaser  
must pay all labor and shipping charges necessary to replace product covered by this warranty.  
HARTELL shall not be held liable for resultant damages, caused by products that have failed.  
Installer must consider the safeguards necessary to protect the surrounding areas from possible  
water damage should the pump or piping system fail. Warranty will be voided if product has been  
subject to abuse, tampering, altering, negligence, improper installation, or mis-application.  
Requests for service under this warranty shall be made by returning the product to the original  
place of purchase along with dated sales receipt. Additional details of this warranty can be obtained  
by contacting HARTELL.  
! WARNING  
Risk of electrical shock. Do not handle pump, cord, or plug  
with wet hands, or when standing in water or on a damp surface, when pump  
is plugged in. Unplug pump before servicing or performing any maintenance.  
Do not work with energized electrical equipment in a wet area. Reasonable  
care and safe practices should be exercised during installation and  
maintenance.  
HARTELL PUMPS 201 Ivyland Rd Ivyland, PA 18974  
Phone: 215-322-0730 Fax: 800-322-5519 E-Mail: [email protected] Web Site: www.hartell.com  

Xerox Nuvera 100 Ea User Manual
Trion Air Boss Dc 24 User Manual
Soleus Air Air Conditioner Sg Ttw 12hc User Manual
Radio Shack Tad 1006 User Manual
Microboards Technology Cd Disc To Disc Office Copier Ii User Manual
LG LRG3193 User Manual
HITACHI 65T500 User Manual
HITACHI 50VX915 User Manual
BROTHER HL L2350DW User Manual
BLONDER TONGUE BIDA 75A 30 User Manual