HP 1810-48G Switch Quick Setup Guide
The switch drawings in this document are for illustration only and may not match your particular switch model.
For more detailed instructions and information to set up your switch, view or download the Installation and Getting Started
1. Unpack and check included parts.
■
■
■
■
Documentation kit
Switch
Accessory kit (installation hardware)
AC power cord
2. Prepare for installation. To avoid personal injury or product damage, review the “Safety Precautions” on
page 4.
3. Power on and verify that Self-Test completes normally. The switch does not contain a power switch. It is turned on
by connecting power through the AC power cord.
After Self-Test:
Power LED = On
Fault LED = Off
4. Install the Switch Hardware. Turn off the switch before installing the switch hardware.
Rack Mounting: Use a #1 Phillips (cross-head) screwdriver to attach the accessory kit brackets to the switch using the
eight 8-mm M4 screws. Then use the four number 12-24 screws to secure the brackets to the rack.
Table or Desktop: Attach the four self-adhesive pads
(included in the accessory kit) to the bottom corners of
the switch.
1
®
Example: Initial Switch Configuration using Windows XP
1. Reconfigure the PC’s IP address and Subnet Mask so that it can communicate with the switch.
a. Click Start > Connect to > Show all connections.
b. Select and right-click Local Area Connection, then click Properties.
c. Scroll and select Internet Protocol (TCP/IP), then click Properties.
Note: Be sure to record all your PC’s current IP settings to be able to restore them later.
d. On the General tab, click Use the following IP address.
e. For IP address, enter an IP address in the same range as the switch’s default IP address. For example, enter 192.168.2.12.
f. For Subnet mask, enter 255.255.255.0, then click OK.
g. Click Close (or OK) to close the Local Area Connection Properties screen.
2. Open your Web browser on the PC, and enter the factory-default address, http://192.168.2.10, to access the switch’s Web interface.
3. Click Log on to log onto the switch (by default, there is no password).
4. Click Network Setup > Get Connected and configure IP network settings on the switch for operation on your network.
Note: If you enable DHCP on the switch for automatic IP network configuration, the switch must be connected to the same network
as the DHCP server. After automatic IP configuration, you must determine the IP address assigned to the switch. To do this, you will
need to access your DHCP server files, or use LLDP (Link Layer Discovery Protocol) commands on a connected device (such as another
switch).
5. Click Maintenance > Save Configuration and save your settings to retain them when the switch is rebooted.
You are done with initial switch configuration. Disconnect the LAN cable.
Be sure to return your PC to its original network settings before connecting to your network.
Mini-GBIC/SFP Installation Notes
Note
Use only genuine HP mini-GBIC/SFP transceivers supported by your switch.
When selecting a fiber SFP device, make sure it can function at a temperature that is not less than the recommended
maximum operational temperature of the product. Use only an approved Laser Class 1 SFP transceiver.
Use only genuine HP Mini-GBICs/SFPs. Non-HP mini-GBIC/SFP transceivers are not supported. Use of genuine HP products ensures
that your network maintains optimal performance and reliability. Should you require additional transceivers, please contact an HP sales
representative or an authorized reseller.
Hot Swapping Mini-GBIC/SFP transceivers. Supported mini-GBIC/SFP transceivers that you can install in your HP switch can be “hot
swapped”—removed and installed after the module is installed in the switch and receiving power. You should disconnect the network cables
from the mini-GBIC/SFP transceivers before hot-swapping them.
When you replace a mini-GBIC/SFP transceiver with another of a different type, the switch may retain selected port-specific configuration
settings that were configured for the replaced unit. Be sure to validate or reconfigure port settings as required.
Mini-GBIC/SFP Connections to Devices with Fixed Speed/Duplex Configurations. When connecting a device to your switch port
that contains a mini-GBIC/SFP transceiver, the speed and duplex settings ofthe switch port and the connected device must match; otherwise,
the device may not link properly — you may not get a link. For some older network devices, including some older HP devices, the default
speed/duplex settings may be predefined (for example, to 1000 Mbps/Full Duplex), or otherwise set differently from the defaultconfiguration
of your switch port. Because of these default speed/duplex considerations, you should make sure that devices connected to your mini-GBIC/
SFP ports are properly configured. At a minimum, make sure the configurations match.
3
Safety Precautions
Toavoidpersonalinjuryorproductdamagewheninstallingyourswitch, readtheinstallationprecautionsandguidelinesbelow.
Installation Precautions
Warnings
■
The rack or cabinet should be adequately secured to prevent it from becoming unstable, tilting or falling.
Devices installed in a rack or cabinet should be mounted as low as possible, with the heaviest devices at the
bottom and progressively lighter devices above.
■
Do not wall-mount any switch without checking for restrictions in the Installation and Getting Started
Guide.
Wall-mount the switch with network ports facing up or down (away from or toward the floor). Do not wall-
mount the switch with the ventilation or fan ducts facing up or down.
Cautions
■
Ensure the power source circuits are properly grounded, then use the powercordsuppliedwith theswitch to connect
to the AC power source.
■
If your installation requires a different power cord than the one supplied with the switch and/or power supply, be
sure the cord is adequately sized for the switch’s current requirements. In addition, be sure to use a power cord
displaying the mark of the safety agency that defines the regulations for power cords in your country/region. The
mark is your assurance that the power cord can be used safely with the switch and power supply.
When installing the switch, the AC outlet should be near the switch and should be easily accessible in case the switch
must be powered off.
Ensure the switch does not overload the power circuits, wiring, and over-current protection. To determine the
possibility of overloading the supply circuits, add together the ampere ratings of all devices installed on the same
circuit as the switch and compare the total with the rating limit for the circuit. The maximum ampere ratings are
usually printed on the devices near the AC power connectors.
■
■
■
■
Do not install the switch in an environment where the operating ambient temperature exceeds its specification.
Ensure the air flow around the switch is not restricted. Leave at least 7.6 cm (3 inches) for cooling. For the air flow
direction, see the Installation and Getting Started Guide for your product, located on the HP ProCurve Web site
For additional Safety and Regulatory information, refer to the Safety and Regulatory documentation included with your switch.
Russia/Belarus/Kazakhstan/CEE Safety:
4
Printed in China
January 2011
© Copyright 2011 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
5998-1280