S.BUS compatible/FASST-2.4GHz (Multi-ch) system
8 channels/high-speed receiver
R6208SB
Thank you for purchasing a Futaba
compatible receiver.
R6208SB S.BUS
Usage condition on "High Speed mode"
CAUTION
The
has an
system output port and a
S.BUS
ꢀ
R6208SB
conventional system channel output. It can also be used with
conventional system servos, etc. in addition to
compatible servos and gyros, etc.
When using the high-speed mode, use a Futaba
ꢁ digital servo (including brushless servo) or S.BUS
servo at conventional system use channels 1 to 6.
Analog servos cannot be used.
system
S.BUS
In addition, the operating mode (high-speed mode/normal
mode) can be selected.
* However, channel outputs 7 and 8 for conventional system oper-
• The use of analog servos may cause servo trouble.
• When using analog servos, select the normal mode, and
ate in the normal mode even if set to the high-speed mode.
use channel outputs 7 and 8.
(on 8ch mode)
(on multi-ch mode)
(on 8ch mode)
(on
T8FG 2.4GHz
, TM14
, TM8
, T10CG 2.4GHz
Applicable systems:
10ch mode)
(on 10ch mode)
, TM10
Link/Mode switch
• Channel outputs for conventional
system (1 to 8)
DATA port
• Battery terminal (B)
• S.BUS Port (S.BUS)
LED
R6208SB
Compliance Information Statement
(for U.S.A.)
R6208SB Specifications
S.BUS compatible/FASST-2.4GHz (Multi-ch) system/8 channels/
high-speed receiver
This device, trade name Futaba Corporation of America, model
number R6208SB, complies with part15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesiredoperation.
• Dual antenna diversity
• Size: 0.98 x 1.86 x 0.56 in. (24.9 x 47.3 x 14.3 mm)
• Weight: 0.49 oz. (13.8g)
• Power requirement: 3.7V to 7.4V
(Voltage range: 3.5 to 8.4V)
The responsible party of this device compliance is:
Futaba Service Center
*Be sure that when using ESC's regulated output the capacity of the ESC
must meet your usage condition.
3002 N Apollo Drive Suite 1, Champaign, IL 61822 U.S.A.
TEL (217)398-8970 or E-mail: [email protected] (Support)
*The Battery F/S voltage is set for 4-cell NiCd/NiMH battery. Battery F/S
function doesn't work properly when other type battery is used.
What is S.BUS?
Different from conventional radio control systems the
30 degrees” to multiple devices. The
devices execute
S.BUS
S.BUS
system uses data communication to transmit control signals
from a receiver to a servo, gyro, or other compatible
only those commands for their own set channel. For this
reason, it can be used by connecting multiple servos to the
same signal line.
S.BUS
device. This data includes commands such as “move the
channel 3 servo to 15 degrees, move the channel 5 servo to
[Connection by S.BUS system]
3ch
5ch
Ch output/
Battery terminal
R6208SB
S.BUS hub
S.BUS hub
6ch
S.BUS
S.BUS output
2ch
4ch
Battery
S.BUS servo
Conventional
servo
* Can also be used together with conventional servos.
* When using servos with a remote battery pack, use S.BUS Hub with Cable (2-way/remote battery pack use).
Please refer to the instruction manual of S.BUS Hub with Cable (2-way/remote battery pack use) for the connection method.
|