Operation Guide CT50  
To turn your CT50 ON, press the MODE button on the right side. This  
cycles the CT50 through HEAT, COOL, AUTO and OFF modes.  
top cover  
The CT50 programmable communicating  
thermostat operates via a high-quality, easy-  
Reset  
button  
HVAC  
Wire  
to-use touch screen. To program or adjust your  
selection  
switches  
terminals  
CT50, simply touch your finger firmly to the  
screen. The screen will automatically light up and  
Save  
Energy  
button  
you will hear a “beep.” The screen will respond  
Mode  
button  
D
AY  
AU  
TO  
PM  
differently to different types of touches, so you  
RA  
D
IO  
Insulation  
indicator  
F
1
LI  
may want to experiment by touching it different  
ways, finger, fingernail, etc. Do not use a sharp or  
metallic device; it will scratch the screen.  
NK  
Fan  
button  
TA  
RGET  
TE  
M
P
COOL  
MENU  
button  
Statement of use: 100% Compatible with all popular  
residential HVAC systems; 24VAC single, two stage  
conventional heating systems (gas/oil/electric), heat  
pumps, single stage or with auxiliary heat (electric  
or fossil), zoned forced air and zoned hot water (2  
or 3 wire), millivolt systems (with a 18-24 AC or DC  
source), one or two stage cooling, and hybrid systems.  
1014-011-001  
PROG  
button  
bottom  
cover  
Touch screen  
ENGLISH  
MENU Screen  
The MENU screen is the gateway to many functions or settings of the  
CT50. It is displayed when you press the MENU button. [See page 10 for details]  
Set Time  
Touch this area to set  
the time of day.  
Left arrow goes back,  
right arrow goes forward.  
Chirp set  
Touch this to turn the  
audible chirp on or off.  
Filter Timer set  
Touch and hold  
5 sec to change.  
o
o
Set C - F  
FILTER  
SWING  
DIFF  
Touch this  
to set temp  
display units.  
Differential to set  
for 2nd Stage start.  
Temperature  
Swing set  
F
Lock Program  
Touch for 5 sec  
to lock or unlock.  
HVAC  
SETUP  
Set Day  
Touch this area to set  
the day of the week.  
CALIBRATE  
Return  
to HOME  
screen.  
Calibration control  
Use this to calibrate your  
LCD display match to  
another thermometer.  
HVAC SETUP  
Touch this in OFF mode to  
configure the unit to work with  
your HVAC system.  
PG 3  
PG 4  
PROGRAM Screen  
The PROGRAM screen sets the CT50 control for your home  
HVAC system. Press PROG for to access it. After that it is displayed when you press the PROG  
button. [See page 8 for details]  
Return HOME  
Set Time Slot  
Touch this area to set the  
Time Slot you want to program.  
When programming is complete  
touch this to run your program and  
return to the HOME screen.  
AM  
Set Program Time  
MORN  
Touch this area to set the  
time of day you want each  
time period to start.  
F
Left arrow goes back,  
right arrow goes forward.  
[Touch and hold for fast set.]  
COPY DAY  
Copy  
HEAT  
Touch this area to copy  
current day’s program  
to the next day.  
PROGRAM  
Temp Up / Temp Down  
Touch these to raise and  
lower each Target Temp.  
[Touch and hold for fast set.]  
Set Program Day  
Touch this area to set the day of the week  
you want to program.  
MANUAL Screen  
The Manual Screen control screen is where you can make  
temporary changes to your CT50’s operation. From the Full HOME screen, touch the main  
temperature display to use this screen. [See page 13 for details]  
Manual Override Indicator  
Target  
Shows TEMPORARY when  
Room  
Temperature  
Temperature  
you have modified the Target Temperature  
Temp Up / Temp Down arrows  
Touch these to raise and lower  
the manual override Target Temp.  
TEMPORARY  
F
Return HOME  
EMER  
HOLD  
HOLIDAY Touch this to invoke a  
single program that repeats day  
after day until you turn it off.  
HOLIDAY  
HEAT  
HOLD Touch this area to operate the thermostat as  
a manual thermostat. It will keep the temperature  
you set until you change it or cancel HOLD.  
EMER heat for  
HEAT PUMP systems.  
PG 5  
PG 6  
Simple HOME Screen  
Make this simple HOME screen the default  
for your CT50, switch the mode to OFF and hold the PROG button for 12 seconds. This Simple  
HOME screen gives you limited access to the CT50’s features, only the target temp can be changed.  
[To return to the regular HOME screen switch the mode to OFF and hold the PROG button for 12  
seconds.]  
Current Room  
Temperature  
F
TARGET TEMP  
COOL  
Thermostat  
Target  
Mode  
Temperature  
Initial Settings  
Press MENU to access the following commands (from HOME screen).  
Set day of the week  
Touch the Day of the week area to cycle through the days of the week to select the current day.  
Set time of day  
Touch the Time of Day arrows to move the time selection forward or backward until  
it displays the current time. Touch and hold for faster setting.  
Backward Forward  
o o  
Set F- C display  
Touch the F and it will toggle to C.  
o
o
Set audible chirp  
Touch the musical note icon to select the chirp or no chirp.  
Return HOME by touching the home icon.  
PG 7  
PG 8  
Run Program  
The CT50 comes pre-programmed with an EPA approved program. This program is recommended by  
the EPA for energy efficiency. We strongly recommend that you Auto-Run this program for one week  
and see if it works for you. If it does not fit your needs, you can always input a custom program.  
To run the EPA program, set the mode switch to HEAT or COOL.  
Press the MENU button and use the arrows by the time display to set the time.  
Touch the DAY area and advance it to select the present day.  
Touch HOME. The unit is now running the program.t  
EPA  
MORN  
6:00am  
70oF  
DAY  
8:00am  
62oF  
EVEN  
6:00pm  
NITE  
10:00pm  
2oF  
MORN  
DAY  
EVEN  
NITE  
HEAT  
COOL  
6:00am  
8:00am  
6:00pm  
10:00pm  
70o  
6
All Days  
78oF  
85oF  
78oF  
82oF  
All Days  
F
TO CHANGE THE PROGRAM:  
Make sure the CT50 mode is set to either HEAT or COOL, then press the PROGRAM button. This  
puts you at the PROGRAM screen [see page 4]. The programmed start time is displayed in the  
upper left. The TIME SLOT icon indicates the active TIME SLOT in the default program [MORN, DAY,  
EVEN, NITE]. The programmed Target Temperature is shown on main display.  
The HEAT program and the COOL program are separate.  
PROGRAM cont.  
Select the day you want to program.  
The day of the week starts at SU - Sunday and can be advanced to the day you want to program.  
Touch the day of the week area to cycle through the days of the week to the desired day.  
Select the time slot (period) you want to program (MORN, DAY, EVEN, NITE).  
Touch the time slot area to cycle through to the desired period.  
Select the desired start time of that time slot.  
Touch the time arrows to select the desired period’s starting time. Hold arrow down for fast time  
scrolling.  
Select the desired target temperature for that time slot.  
Touch the +/- arrows to select the desired period’s temperature.  
To COPY one day’s programming to the next day, touch COPY DAY once. The information for the  
current day will be copied to the next day which will appear on the screen. Holding down COPY for  
over 3 seconds will copy to all 7 days.  
Touch  
to return to the Home screen.  
PG 9  
PG 10  
MENU Screen Functions  
Press MENU to bring up MENU screen.  
TIME of DAY  
Touch the left (backward) or right (forward) arrows next to the time display to set  
the current time (1 minute per touch). Touch and hold the arrow for fast time set (15 minute jumps).  
DAY of Week Touch DAY area to select present day.  
SWING (HVAC cycling rate) This feature allows you to set the desired variance in temperature  
between the CT50 setting and the room temperature required before the heating or cooling system  
will turn on—from 0.5° to 2.0° F (.25° to 1° C). For example, if SWING is set to 2.0° F and the CT50  
is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to 68°F.  
Similarly, the cooling system will start when the room temperature increases to 72°F. The HVAC then  
runs and will shut off at the Target Temperature.  
To set SWING:  
Touch SWING.  
Touch the left/right arrows to set the SWING from 0.5° to 2.0°F.  
The HVAC will run more frequently at .5°F and less at 2°F. Default is 1°F.  
Touch  
to return to the MENU screen.  
Chirp set - Touch this to turn the audible chirp sound on or off.  
F
C
o
o
Set - Touch this to change the temperature display scale from F to C .  
FILTER - AIR FILTER ALERT - The CT50 can be programmed to remind you when the HVAC  
sytem’s air filter needs changing.  
Touch FILTER. The display will show the usage to date.  
Touch FILTER for over 3 seconds and the display will change to LIMIT.  
Touch arrows to set desired usage limit before filter alert comes on home screen.  
When this limit is reached, FILTER will be on home screen and the CHECK FILTER indicator lights.  
Limit may be set from 0 to 999 days/99 weeks; default is 90 days/12 weeks. Touch to reset.  
To reset the usage back to 0, touch usage number; touching it again restores the displayed usage.  
Touch  
to return to the MENU screen.  
LOCK (The CT50 has 2 lock modes)  
Touch icon for 5 seconds; the unit will go into the PARTIAL lock mode. The user can temporarily  
override the CT50 target with the +/- buttons only. (1 bar)  
For FULL lock : Touch the (1 bar) icon again for 5 seconds to go to full lock. No changes can be  
made in full lock (2 bars). Once locked, the CT50 will respond just to mode and menu.  
To UNLOCK , Press MENU.  
Touch and hold icon for 5 seconds for 2 bars (if not there already).  
Then touch and hold the icon for another 5 seconds. Each 5 second touch and hold must be separate.  
Touch  
to return to the Home screen.  
PG 11  
PG 12  
CALIBRATE  
Your thermostat was accurately calibrated at the factory to ±1° F of actual ambient  
temperature. You do have the option, however, to change the display temperature to match that of a  
previous thermostat, or to match another thermostat already in your home. The range of change is  
from -6°F to +6°F or -3°C to +3°C.  
To change your Thermostat Calibration, touch MENU and then touch CALIBRATE.  
Use the + / - to adjust the displayed temperature up or down, as desired.  
The DELTA FACTOR that appears on the screen will also automatically increase or decrease  
for each 0.5° (F or C) adjustment so you can see your change. The large display will show the  
modified temerature reading that will be displayed on the HOME screen and used as the new room  
temperature.  
Touch  
to return to the Home screen.  
DIFF (Used for 2 stage normal or heat pump with auxiliary only, not on screen for single stage)  
The differential is the number of degrees between the room temperature and the Target Temperature  
at which the 2nd stage will be used. Default is 2°F.  
Touch MENU and then DIFF. Use the arrows to set the DIFF.  
Recommend 2°F for very cold climates and the 4°F for warm climates.  
MANUAL Screen Functions  
The CT50 has 4 manual override commands. The manual screen is accessed by touching the large  
current temperature display in the middle of the HOME screen.  
IMPORTANT: The Mode must be in HEAT or COOL to access the manual screen.  
TEMPORARY override Touch the + / - arrows to select your desired temporary Target  
Temperature. Touch HOME to return to operation. The TEMPORARY icon will display indicating  
you have modified the Target Temperature for the current Time Slot only. It goes back to the  
program target at the next period. Also, when in TEMPORARY, if the target is set the same as the  
programmed target for that period, the word TEMPORARY will go out.  
HOLD This will hold the target temperature you set indefinitely, until you turn HOLD off. HOLD will allow  
you to operate your thermostat as a manual thermostat. It will keep whatever temperature you set until  
you change it or cancel hold. Take care using the HOLD function as the program is now bypassed. To set  
a hold target temperature, touch HOLD and use the +/- icons to select your hold temperature. The HOLD  
icon will display on the HOME screen indicating you have changed the Target Temperature. The system  
will HOLD this temperature until you return to the manual screen and de-select HOLD by touching it. Hold  
is also canceled when you set the mode to OFF.  
HOLIDAY This is a single program that repeats day after day until you turn it off. It supersedes the  
PG 13  
PG 14  
weekly program. To use it touch HOLIDAY on the temporary screen. The default holiday program is  
shown here [Default program: HEAT 70oF all day and 62oF at night. COOL 78oF all day and 82oF  
at night.] To modify this program, touch the PROGRAM button and then touch the DAY area until  
HOLIDAY appears (after SAT). The default HOLIDAY program is set as 2 time slots; all day (same  
target MORN, DAY and EVEN) and a different target for NITE.  
EMER (in HEAT PUMP type)  
If you set your CT50 for HEAT PUMP with auxiliary heat, EMER function is available on the MANUAL  
screen. If you touch EMER, it displays EMER|ON. Your HEAT PUMP is disabled and auxiliary heat  
is your sole source of heat. This manual override stays active until you toggle EMER off. Auxiliary  
heat is more expensive than the heat pump so use EMER only if the heat pump cannot keep up or is  
defective.  
Other Functions  
Save Energy Button  
The “Save Energy” feature on the CT50 provides a simple, easy-to-use way to help you manage your  
energy use. SAVE ENERGY automatically adjusts your Target Temperature up in COOL or down in  
HEAT by 4oF. To use Save Energy, press the Save Energy button in the upper left corner of the unit.  
The screen will now read “Save Energy”. To return to normal operation, press the “Save Energy”  
button again. This is useful to save energy if you are gone for a short time.  
MODE Button  
The mode button sets the CT50 to HEAT, COOL, AUTO, or OFF modes. Press it once to step to the  
next mode. If the CT50 is in OFF and you want to return to the mode you were previously in, touch  
the OFF indicator on screen.  
COOL - This will operate the cooling portion of your HVAC system until it is turned off.  
HEAT - This will operate the heating portion of your HVAC system until it is turned off.  
AUTO - The CT50 TRUE AUTO mode switches automatically between heat and cool throughout  
the year. Unlike other manufacturers, the CT50 TRUE AUTO has no temperature or time limitations  
(Patent pending), just program your desired HEAT and COOL temps and select the AUTO mode. The  
CT50 will switch from HEAT to COOL as needed.  
OFF- This takes your HVAC system “off-line” and it will not control HVAC  
functions.  
In this mode your house may experience extreme heat or cold.  
FAN Button  
The fan control is normally in AUTO mode, meaning that the fan operates automatically with the  
HVAC system and the thermostat. When the fan button is pressed the fan goes ON; the fan will run  
continuously in this manual override until switched back to AUTO by pressing the FAN button again.  
[NOTE: Fan ON function is available in the OFF mode to allow simple ventilating.]  
PG 15  
PG 16  
Simple Screen  
This display mode limits the amount of information on screen and limits the functions to just the +/- arrows  
and the MENU button. To set, with mode in OFF and ...  
Hold down the PROGRAM button for 12 seconds to access the limited display screen.  
Hold down the PROGRAM button for 12 seconds to leave the limited display screen.  
RESET button The RESET button re-boots the CT50 processor. It does not effect the user programs that  
have been stored in permanent memory.  
Compressor Protection The CT50 has a minimum cycle time of 4 minutes to protect your  
compressor in cool and in heat pump (if you have one). The Home screen will show a small clock and A/C  
during this time and the compressor will not come on until the 4 minute delay is over.  
USNAP  
radio  
Communicating Thermostat  
The CT50 has 2 USNAP radio ports. These allow your thermostat  
to communicate with other systems.  
Using USNAP Radios The USNAP ports allow you to  
connect your CT50 to your home WiFi network. This can give you  
access to your home’s HVAC system even when you are away  
[with additional web service]. It can also give you access to web  
based efficient energy management sites that can help you save  
money and protect the environment.You can connect your CT50  
to a Home Automation network for HA functionality with remote  
access to your HVAC system and home conditions.  
USNAP port  
To Insert a USNAP radio module:  
Power off the CT50. Insert the radio module in either slot on the back of the CT50.  
Power up CT50.  
To connect to a network follow the instructions  
that came with the USNAP module.  
Caution  
DO NOT INSERT or REMOVE USNAP radio  
modules if power is ON. This can damage the  
thermostat or radio modules.  
PG 17  

Sanyo Dc Inverter Split System Xhs1271 User Manual
Samsung Sc X220l User Manual
Panasonic Dp 6000 User Manual
NEC MULTISYNC X401S User Manual
Metrologic Instruments Voyagergs Ms9590 User Manual
MAKITA RP1101 User Manual
Lexmark All In One Printer X500n User Manual
JVC AV 20F704 User Manual
EPSON C82362 User Manual
ASUS VP247HAE User Manual