CREE CS18 User Manual

CS Series  
CS18 and CS14 LED LINEAR LUMINAIRE  
8’ and 4’ LUMINAIRE  
IMPORTANT SAFEGUARDS  
INSTALLATION INSTRUCTIONS  
READ AND FOLLOW ALL SAFETY INSTRUCTIONS  
1. Before installing this fixture or doing any maintenance, make sure to turn off the power  
supply at the circuit breaker or fuse box.  
2. Do not handle energized module with wet hands or when standing on wet or damp surfaces,  
or in water.  
3. Check to make sure that all the fixture connections have been properly made and  
the fixture is grounded to avoid potential electrical shocks.  
4. Product must be installed in accordance with NEC or your local electrical code. If you  
are not familiar with these codes and requirements, consult a qualified electrician.  
WARNING - Risk of Electric Shock. Suitable for damp locations. Maximum connected load with  
a single power supply shall not exceed maximum ampacity rating of #12 AWG THHN through-  
wire conductors. Use only lighting controls with relay or FET-based outputs, or lighting controls  
options. Avoid handling LEDs directly. Not intended for use in environments containing airborne  
corrosive agents such as chemical solvents, cleaners, or cutting fluids  
The CS Series LED linear luminaire is for suspended, with cable or threaded rod, or surface mount applications using appropriate tong  
hangers. Reference individual mounting accessory installation instructions for specific mounting types.  
Designed for use in 120–277V, 50-60 Hertz protected circuit (fuse box, circuit breaker) and supply wire shall be rated minimum 12AWG,  
600V, 90 C rated).  
TO INSTALL:  
NOTE: When removing luminaire from packaging,  
keeping protective plastic wrap on fixture during  
installation and construction.  
1
2
FOR PLASTIC TONG HANGERS (TM):  
NOTE: Center hole can accommodate 1/2” diameter  
rod maximum.  
STEP 1:  
Remove cross brace and securely insert it into the  
“+” shaped openings in the plastic tong hanger. See  
Figures 1 & 2. For single units or end row fixtures, place  
the plastic tong hanger assembly into center spine  
no more than 18” from each end of fixture and twist  
approximately 45 degrees until the plastic tong hanger  
assembly is securely in place and approximately 90  
degrees to the length of fixture. See Figure 3.  
Cross Brace  
Cross Brace  
3
STEP 2:  
For continuous row installation, continue with next fixture  
using a minimum of one tong hanger per unit. Each  
bracket should be properly snug and be difficult to slide  
along the back spine.  
18”  
18”  
FOR OPTIONAL METAL TONG HANGERS (TMM):  
NOTE: Center hole can accommodate 3/8” diameter rod  
maximum. Recommended for surface mount installations.  
4
5
STEP 1:  
For single units or end row fixtures, place metal tong  
hanger bracket over center spine no more than 18” from  
each end of fixture. See Figure 3. Insert supplied bolt  
through the metal tong hanger and secure with lock  
washer and nut, tightening to secure spine to the metal  
tong hanger. See Figure 4 & 5. Additional suspension  
points are optional depending on field conditions.  
STEP 2:  
For continuous row installation, continue with next  
fixture using a minimum of one tong hanger per unit.  
Each bracket should be properly snug and be difficult to  
slide along the back spine.  
1 of 2  
LPN000106_D  

York Air Conditioner R 410a User Manual
Trion Air Bear Series User Manual
Sterling Power Products 2425ce User Manual
Sharp Tinse4796fczz User Manual
Samsung Scx 4200 User Manual
Rena Da615 User Manual
Nec Rih 6867 User Manual
LG LSAA012 UX5 02 User Manual
D LINK DES 1005E User Manual
BLACK DECKER W006B User Manual