VEC1031CBD_ManualEN_032906 7/7/06 9:42 AM Page 8  
VEC1031CBD  
TRO UBLESHO O TIN G  
Un it Fa ils to Ju m p -Sta rt  
• Make sure unit’s power switch is in the ON position.  
• Check that Jump-Starter/ Inflator has a full charge.  
• Make sure a proper polarity cable connection has been established (see “Using  
the Unit as a Jump-Starter,” page 3).  
1 2 Vo lt O u tle t Fa ils to De live r Po w e r  
START-IT®  
• Make sure a proper 12 volt adapter connection has been established.  
• Check that the unit has a full charge.  
Ju m p -Sta rte r/ In fla to r/  
1 2 Vo lt O u tle t Sh u ts O ff  
Disconnect unit and allow to cool for 10 minutes.  
N o te : W h e n p u llin g m o re th a n 5 a m p s fro m th e 1 2 vo lt o u tle t, u n it w ill sh u t o ff.  
Re ch a rg e a b le Po w e r Su p p ly  
LED Are a Lig h t Do e s N o t Co m e O n  
• Check that the unit has a full charge.  
SPECIFICATIO N S  
Jump-Start Clamps:  
Jumper Cables:  
300 amps – heavy-duty copper  
#6 AWG welding cable  
Instant Amps:  
300  
5 Second Amp:  
225  
Battery High Density AGM:  
Worklight Bulb:  
12 volt, 9 Ah, sealed, lead-acid  
Long-life LED  
Accessory Outlet Protection: 5 amps, self-resetting breaker  
USER’S MAN UAL  
& WARRAN TY IN FO RMATIO N  
IMPO RTANT SAFETY INFO RMATIO N, SAVE THESE INSTRUCTIO NS  
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND  
THIS INSTRUCTIO NAL MANUAL. THIS MANUAL CO NTAINS IMPO RTANT  
INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS  
PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.  
4140 S.W. 30th Ave., Ft. Lauderdale, FL 33312 U.S.  
Toll Free: (800) 618-5178  
w w w .ve cto rm fg .co m  
8
VEC1031CBD_ManualEN_032906 7/7/06 9:42 AM Page iv  
TABLE O F CO N TEN TS  
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1
TW O YEAR LIMITED WARRAN TY PRO GRAM  
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
This limited warranty program is the only one that applies to this product, and it sets forth all the  
responsibilities of Vector Products, Inc., regarding this product. There is no other warranty, other than  
those described herein. Any implied warranty of merchantability or fitness for a particular purpose on  
this product is limited in duration to the duration of this warranty.  
Battery Charge Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
12 Volt DC Accessory Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
120 Volt AC Recharge Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Emergency LED Area Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Using the Emergency LED Area Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Using the Jump-Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Using the 12 Volt DC Portable Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Using the Alternator Check Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Using the Portable Inflator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Inflating Tires or Products With Valve Stems . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Inflating Other Inflatables Without Valve Stems . . . . . . . . . . . . . . . . . . . . . . . .  
2
2
2
2
2
3
3
4
4
4
5
5
This Vector Products, Inc. product is warranted, to the original purchaser only, to be free of defects in  
materials and workmanship for two years from the date of purchase without additional charge. The  
warranty does not extend to subsequent purchasers or users. Manufacturer will not be responsible for  
any amount of damage in excess of the retail purchase price of the product under any circumstances.  
Incidental and consequential damages are specifically excluded from coverage under this warranty.  
This product is not intended for commercial use. This warranty does not apply to damage to units from  
misuse or incorrect installation/ connection. Misuse includes wiring or connecting to improper polarity  
power sources.  
RETURN/ REPAIR POLICY: Defective products may be returned to manufacturer. Any defective product  
that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge.  
If such a product is returned more than 30 days but less than two years from the purchase date,  
manufacturer will repair the unit or, at its option, replace it, free of charge.  
If the unit is repaired, new or reconditioned replacement parts may be used, at manufacturers option.  
A unit may be replaced with a new or reconditioned unit of the same or comparable design. The  
repaired or replaced unit will then be warranted under the terms of the remainder of the warranty  
period. The customer is responsible for the shipping charges on all returned items. During the warranty  
period, manufacturer will be responsible for the return shipping charges to the customer in the United  
States.  
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
Charging/ Recharging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Fuse Replacement (12 Volt DC Charging Adapter) . . . . . . . . . . . . . . . . . . . . . .  
Battery Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
6
7
7
7
8
8
LIMITATIONS: This warranty does not cover accessories, such as charging adapters, bulbs, fuses and  
batteries, damage or defects resulting from normal wear and tear (including chips, scratches, abrasions,  
discoloration or fading due to usage or exposure to sunlight), accidents, damage during shipping to our  
service facility, alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow  
instructions for care and maintenance, fire, flood and Acts of God.  
If your problem is not covered by this warranty, call our Technical Support Department at (800) 618-  
5178 for general repair information and charges if applicable. You may also contact us through our  
website at www.vectormfg.com.  
IN TRO DUCTIO N  
Thank you for choosing the Bla ck  
&
De ck e r Ju m p -Sta rte r/ In fla to r/  
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations  
on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential  
damages, so the exclusions or limitations stated herein may not apply. This warranty gives the purchaser  
specific legal rights; other rights, which vary from state to state, may apply.  
Re ch a rg e a b le Po w e r Su p p ly. This compact jump-starter is unique in the  
amount of energy it can supply for its size. The internal battery is a high density  
sealed, lead-acid battery that stores and delivers energy comparable to full sized  
ordinary jump-starters. Please read this guide carefully before use to ensure  
optimum performance and avoid damage to the unit or items you are using it with.  
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Technical Support by telephone, fax  
or mail (see below). We suggest that you keep the original packaging in case you need to ship the unit.  
When returning a product, include your name, address, phone number, dated sales receipt (or copy)  
and a description of the reason for return and product serial number. After repairing or replacing the  
unit, we will make every effort to return it to you within four weeks.  
The VEC1 0 3 1 CBD is a compact, durable, portable jump-start system for vehicles  
that have a standard 12 volt battery system. This self-contained, rechargeable  
system will start most vehicles without the need for a host vehicle or 120 volt AC  
power supply. It can also be used as a safe, portable source of 12 volt DC electric  
power in remote locations and/ or emergency situations. It is ideal for use with 12  
volt DC cordless, rechargeable products and DC/ AC power inverters.  
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector Products, Inc..  
®
Enter “VEC1031CBD” as Model and “START-IT Jump-Starter/ Inflator” as Product Type. All Vector  
products must be registered within 30 days of purchase to activate this warranty. Mail the completed  
registration form, along with a copy of the original sales receipt, to:  
FEATURES  
ATTN.: CUSTOMER SERVICE  
4140 SW 30th Ave., Ft. Lauderdale, FL 33312  
TOLL FREE: (800) 618-5178 •  
Keyless ON/ OFF Power Switch  
• Cordless/ rechargeable, includes AC and DC charging adapters  
Built-in non-spillable, maintenance-free, heavy duty, 9 amp/ hour, sealed,  
lead-acid battery  
WARRANTY IS NON-TRANSFERABLE.  
Requires no maintenance (other than recharging) for optimum operation  
• Heavy duty, industrial grade copper clamps, and #6 AWG jumper cables with  
exclusive recessed cable holsters  
BD032906  
120 volt AC charger is listed by Underwriter Laboratories  
• Easy-to-read Battery Status LED Indicators  
© 2006 VECTOR PRODUCTS, INC.  
MADE IN CHINA  
1
VEC1031CBD_ManualEN_032906 7/7/06 9:42 AM Page 2  
• Alternator Check  
USIN G THE EMERGEN CY LED AREA LIGHT  
The area light is controlled by the Area Light Power Switch (see the diagram above).  
Make sure the lamp is turned OFF when the unit is being recharged or stored.  
Built-in portable inflator for vehicle tires, trailer tires and recreational inflatables  
Reverse polarity protection  
• ETL listed  
PRESSURE  
GAUGE  
KEYLESS O N/ O FF  
PO W ER SW ITCH  
INFLATO R PO W ER  
SW ITCH  
PUSHBUTTO N FO R  
BATTERY STATUS CHECK  
USIN G THE JUMP-STARTER  
BATTERY STATUS  
LED INDICATO RS  
This Jump-Starter is equipped with a keyless Power Switch that only allows energy  
to flow when proper connections are made to battery and frame. Once the  
connections are properly made, turn the switch ON to jump-start the vehicle.  
1 2 VO LT DC  
ACCESSO RY O UTLET  
1. Turn OFF vehicle ignition and all accessories (radio, A/ C, lights, connected cell  
phone chargers, etc.). Place vehicle in “park” and set the emergency brake.  
1 2 0 VO LT AC  
RECHARGING PO RT  
2. Make sure the Jump-Starter Power Switch is turned to OFF.  
3. Remove jumper clamps from clamp tabs. Co n n e ct th e re d cla m p first, th e n  
th e b la ck cla m p .  
ALTERNATO R CHECK  
INDICATO R  
4. Procedure for jump-starting  
battery terminal is connected to chassis) (MOST COMMON)  
a
NEGATIVE GROUNDED SYSTEM (negative  
REVERSE PO LARITY  
INDICATO R  
PO SITIVE (+)  
RED CLAMP  
4a. Connect POSITIVE (+) RED clamp to vehicle batterys POSITIVE terminal.  
NEGATIVE (–)  
BLACK CLAMP  
AIR HO SE  
CO NNECTO R  
(CHUCK)  
4b. Connect NEGATIVE () BLACK clamp to chassis or a solid, non-moving,  
metal vehicle component or body part. NEVER CLAMP DIRECTLY TO  
NEGATIVE BATTERY TERMINAL OR MOVING PART.  
EMERGENCY LED AREA  
LIGHT PO W ER SW ITCH  
EMERGENCY  
LED AREA LIGHT  
Ba tte ry Ch a rg e Sta tu s LED In d ica to rs  
5. Procedure for jump-starting POSITIVE GROUNDED SYSTEMS  
N o te : In th e ra re e ve n t th a t th e ve h icle to b e sta rte d h a s a PO SITIVE GRO UN D  
SYSTEM (p o sitive b a tte ry te rm in a l is co n n e cte d to ch a ssis), re p la ce ste p s 4 a  
a n d 4 b a b o ve w ith ste p s 5 a a n d 5 b , th e n p ro ce e d to ste p 6 .  
A series of four LED indicators (three red and one green) display the level of charge  
in the battery. The right red LED indicates minimum battery charge. Charge the  
battery when only a single red LED is lit. The center red LEDs indicate moderate  
battery charge level. When the green LED is lit, the battery is at full charge. The  
Charge Status LEDs will light when the Battery Status Check Pushbutton is pressed,  
or automatically during AC charging. During DC recharging, the Battery Status  
Check Pushbutton can be pressed periodically to monitor recharging progress.  
5a. Connect NEGATIVE () BLACK clamp to vehicle batterys NEGATIVE terminal.  
5b. Connect POSITIVE (+) RED CLAMP to vehicle chassis or a solid, non-  
moving, metal vehicle component or body part. NEVER CLAMP DIRECTLY  
TO POSITIVE BATTERY TERMINAL OR MOVING PART.  
6. When clamps are connected properly, turn the Jump-Starter Power Switch to ON.  
7. Turn ON the ignition and crank the engine in 5-6 second bursts until engine starts.  
8. Turn the Jump-Starter Power Switch back to the OFF position.  
1 2 Vo lt DC Acce sso ry O u tle t  
This accessory outlet, covered by a rubber cap, powers and recharges appliances  
that are 12 volt DC compatible. The 12 Volt DC Accessory Outlet is also used for DC  
recharging from a vehicle or other 12 volt source.  
9. Disconnect the NEGATIVE () engine or chassis clamp first, then disconnect the  
POSITIVE (+) battery clamp.  
1 2 0 Vo lt AC Re ch a rg in g Po rt  
The AC Recharging Port is also covered by a rubber cap. The 120 Volt AC Charging  
Adapters barrel connector plugs into this port during recharge.  
FO LLO W ALL DIRECTIO N S FO UN D IN THE IMPO RTAN T SAFETY  
INSTRUCTIO NS SECTIO N AT THE BEGINNING O F THIS USER’S MANUAL.  
Em e rg e n cy LED Are a Lig h t  
Located on the center of the control panel, the Emergency LED Area Light provides  
proper lighting while changing a tire or connecting the unit to a battery.  
WARN IN GS  
• Jum p -Sta rte r Po w e r Sw itch sh o uld b e O FF p rio r to jum p -sta rtin g .  
Th is p o w e r syste m is to b e use d O NLY o n ve h icle s o r b o a ts w ith  
1 2 vo lt DC b a tte ry syste m s.  
Ap p lica tio n s  
Ne ve r to uch RED a n d BLACK cla m p s to g e th e r — th is ca n ca use  
d a n g e ro us sp a rk s, p o w e r a rcin g , a n d / o r e x p lo sio n .  
• Jump-start most engines with standard 12 volt DC battery systems, such as small  
trucks, cars, RVs, tractors, etc.  
• Ve h icle s th a t h a ve o n -b o a rd co m p u te rize d sy ste m s m a y b e  
d a m a g e d if ve h icle b a tte ry is jum p -sta rte d . Be fo re jum p -sta rtin g th is  
typ e o f ve h icle , re a d th e ve h icle m a n ua l to co n firm th a t e x te rn a l-  
sta rtin g a ssista n ce is a d vise d .  
• Using the 12 volt accessory outlet, operate such appliances as 12 volt DC fans,  
fluorescent worklights, spotlights, TVs, portable radios or CD players; and quick-  
charge a cell phone using the phones 12 volt DC adapter cord.  
Illuminate areas under the hood, inside tents and work areas.  
Inflate tires, air mattresses, basketballs, volleyballs, and more.  
• Ex ce ssive e n g in e cra n k in g ca n d a m a g e th e ve h icle ‘s sta rte r m o to r. If  
th e e n g in e fa ils to sta rt a fte r th e re co m m e n d e d n um b e r o f a tte m p ts,  
2
3
VEC1031CBD_ManualEN_032906 7/7/06 9:42 AM Page 4  
d isco n tin ue jum p -sta rt p ro ce d ure a n d lo o k fo r o th e r p ro b le m s th a t  
n e e d to b e co rre cte d .  
required, fitting an appropriate nozzle to the air hose. An On/ Off Switch located  
on the back of the unit controls the power to the Inflator and the Pressure Gauge  
light. Refer to the diagram on page 2 for locations of inflator hose and nozzle  
storage hatch. Return hose to the storage compartment after use.  
• Afte r use , turn th e Jum p -Sta rte r Po w e r Sw itch O FF.  
• Re p la ce w o rn o r d e fe ctive p a rts im m e d ia te ly — co n ta ct th e Custo m e r  
Se rvice De p a rtm e n t to ll fre e (8 0 0 ) 6 1 8 -5 1 7 8 .  
WARN IN GS  
• Th e in fla to r is ca p a b le o f in fla tin g up to 1 2 0 p o un d s p e r sq ua re in ch  
(p si) p re ssure . To a vo id o ve r-in fla tio n , ca re fully fo llo w in structio n s  
o n a rticle s to b e in fla te d . Ne ve r e x ce e d re co m m e n d e d p re ssure s.  
Burstin g a rticle s ca n ca use se rio us in jury.  
CAUTIO N S  
If the audible Reverse Connection Polarity Alarm sounds after clamps are  
connected to vehicle battery, turn the unit OFF and reverse clamp connections  
before continuing.  
• Alw a ys ch e ck p re ssure w ith th e p re ssure g a ug e .  
Ne ve r le a ve th e in fla to r un a tte n d e d w h ile in use .  
If vehicle fails to start, turn OFF the ignition, turn OFF the Jump-Starter Power  
Switch, disconnect the jump-start systems leads and investigate why the engine  
did not start.  
CAUTIO N  
Recharge this unit fully after each use.  
Do not operate inflator continuously for extended periods of time (approximately 15  
minutes, depending on ambient temperatures), as it may overheat. In such event,  
inflator will automatically shut down and restart after a cooling down period of  
approximately 15 minutes.  
USIN G THE ALTERN ATO R CHECK FEATURE  
1. Make sure the Jump-Starter Power Switch is turned to OFF.  
In fla tin g Tire s o r Pro d u cts W ith Va lve Ste m s  
1. Place connector (chuck) on valve stem.  
2. Remove jumper clamps from clamp tabs and connect to vehicle (refer to the  
“Using the Jump-Starter” section for notes about polarity).  
2. Ensure connector is pushed on to valve stem as far as possible before closing  
thumb latch.  
3. Start the engine.  
4. Turn all vehicle accessories OFF.  
5. Turn the Jump-Starter Power Switch to ON.  
3. Make sure latch is secure.  
4. Turn ON the Inflator Power Switch.  
5. Check pressure with the pressure gauge.  
6. Observe the Alternator Check Indicator. A solid green LED indicates a good  
alternator. A solid red LED indicates a bad alternator.  
6. When desired pressure is reached, open thumb latch and remove connector  
from valve stem.  
USIN G THE 1 2 VO LT DC PO RTABLE PO W ER SUPPLY  
This portable power source is also for use with all 12 volt DC accessories equipped  
with a male accessory outlet plug that are rated up to 5 amps.  
7. Turn OFF Inflator Power Switch.  
8. Allow unit to cool before storing away.  
9. Store inflator hose and tire fitting in storage compartment.  
1. Lift up the cover of the unit‘s 12 Volt DC Accessory Outlet.  
2. Insert the 12 volt DC plug from the appliance into the 12 volt accessory outlet  
on the unit.  
3. Switch on the appliance and operate as usual.  
In fla tin g O th e r In fla ta b le s W ith o u t Va lve Ste m s  
Inflation of other items requires use of one of the adapters (nozzles).  
1. Select the appropriate nozzle, located in the storage compartment on the back  
of the unit.  
4. Periodically press the Battery Charge Level Pushbutton to check battery status.  
CAUTIO N  
2. Insert appropriate adapter (i.e. needle) into connector (chuck) and close thumb  
latch.  
Make sure the Jump-Starter Power Switch is ALWAYS in the OFF position when using  
the unit’s 12 Volt DC Accessory Outlet.  
3. Insert adapter (i.e., needle) into item to inflate to appropriate pressure.  
4. Turn ON the Inflator Power Switch — inflate to desired pressure or fullness.  
5. Switch the Inflator Power Switch OFF.  
DO NOT operate appliances that draw more than 5 amps.  
USIN G THE PO RTABLE IN FLATO R  
6. Remove adapter.  
The built-in 12 volt DC inflator is the ultimate inflator for all vehicle tires, trailer tires  
and recreational inflatables. Three different sized nozzles are supplied. Each nozzle  
will clip on the end of the standard tire valve connector located at the free end of  
the inflator hose. The inflator nozzles are stored inside the hose hatch. The inflator  
hose with tire fitting is stored in a retaining channel between the jumper cable  
channels on the rear of the unit. The inflator can operate long enough to fill up to  
3 average sized tires before the battery must be recharged.  
7. Recharge the unit before storing away.  
CARE AN D MAIN TEN AN CE  
This product has a sealed lead acid battery that should be kept fully charged.  
Recharge before first use, immediately after each use, and every 60 days if not  
used. Failure to do this may reduce battery life dramatically.  
5
The inflator may be used by removing the air hose from the storage hatch and if  
4
VEC1031CBD_ManualEN_032906 7/7/06 9:42 AM Page 6  
N o te : Th is u n it is d e live re d in  
a
p a rtia lly ch a rg e d sta te – y o u m u st fu lly ch a rg e it  
• DO NO T le a ve th e un it un a tte n d e d w h ile ch a rg in g usin g th is m e th o d .  
b e fo re u sin g it fo r th e first tim e . In itia l AC ch a rg e sh o u ld b e 4 0 h o u rs.  
1. Insert the gold-tipped 12 Volt DC Charging Adapter plug into the vehicles 12  
volt DC accessory outlet.  
Ch a rg in g / Re ch a rg in g  
2. Insert the silver-tipped end plug into the 12 volt DC accessory outlet on the front  
panel of the unit.  
Lead-acid batteries require routine maintenance to ensure a full charge and long  
battery life. All batteries lose energy from self-discharge over time and more rapidly  
when they are at higher temperatures. Therefore, batteries need periodic charging  
to replace energy lost through self-discharge. When the unit is not in frequent use,  
Black & Decker recommends the battery be recharged at least every 60 days.  
3. Charge the unit until the green FULL indicator lights when the battery status level  
pushbutton is pressed. DO NOT EXCEED 4 HOURS MAXIMUM.  
4. When charging is complete, remove the charging cord and store in a safe place.  
Check the battery charge level by pressing the battery status button. The LED charge  
status display will indicate the level of battery charge. When only one red LED  
lights, recharge the unit.  
N o te : Re ch a rg in g b a tte ry a fte r e a ch u se w ill p ro lo n g b a tte ry life ; fre q u e n t h e a vy  
d isch a rg e s b e tw e e n re ch a rg e s a n d / o r o ve rch a rg in g w ill re d u ce b a tte ry life .  
N o te s: Ma k e su re th e O N / O FF Sa fe ty Sw itch a n d Are a Lig h t a re tu rn e d O FF d u rin g  
re ch a rg e a s th is m a y slo w th e re ch a rg in g p ro ce ss.  
So m e ve h icle s re q u ire th a t th e ig n itio n b e sw itch e d to th e a cce sso ry o u tle t  
p o sitio n in o rd e r to p o w e r th e a cce sso ry o u tle t.  
Re p la ce m e n t Pa rts  
The battery can be recharged using either the AC or DC Charging Adapter (see below).  
For replacement parts (batteries, charging adapters, etc.), contact Black & Decker  
Technical Support: toll free (800) 618-5178. There are no user serviceable parts  
inside the unit. Periodically, the cables and connectors should be inspected for  
damage, corrosion, dust, and dirt. If surfaces are dirty, they can be wiped clean  
with a cloth moistened with water and a drop of detergent. Contacts can be wiped  
clean with a dry cloth.  
1 2 0 VO LT AC  
CHARGING  
ADAPTER  
1 2 VO LT DC  
CHARGING ADAPTER  
WARN IN G  
Do n o t o p e ra te un it if th e re is a n y e vid e n ce o f d a m a g e . Th e p ro d uct  
m ust b e re turn e d to Bla ck & De ck e r fo r te stin g a n d re p a ir. Re p la ce a n y  
d a m a g e d ch a rg in g a d a p te rs im m e d ia te ly b e fo re furth e r use .  
CAUTIO N  
Ma k e sure th e O N/ O FF Po w e r Sw itch a n d Em e rg e n cy Are a Lig h t a re  
turn e d O FF d urin g re ch a rg in g , a s th is m a y slo w th e re ch a rg e fun ctio n .  
Fu se Re p la ce m e n t (1 2 Vo lt DC Ch a rg in g Ad a p te r)  
1. Remove the plug from the accessory outlet. Remove the gold cap by turning  
counterclockwise and lifting off.  
1 2 0 Vo lt AC Ch a rg in g / Re ch a rg in g  
The 120 Volt AC Charging Adapter is a UL listed “wall” type unit that operates from  
any 120 volt, 60 Hz AC supply that has a standard North American outlet. The  
adapter has a barrel connector that plugs into the unit’s 120 Volt Recharging Port.  
2. Remove the center pin and spring. Remove the fuse.  
3. Replace the fuse with a same type and size fuse (8 amp).  
4. Replace the center pin and spring inside the plug.  
5. Replace the gold cap by turning clockwise onto the plug.  
Make sure the Jump-Starter Power Switch and Area Light Power Switch are turned  
OFF during AC charging/ recharging. When the 120 Volt AC Charging Adapter is  
plugged into the 120 Volt AC Recharging Port, the Battery Charge Status LED  
Indicators will automatically light. As recharge progresses, the red LEDs will light,  
one by one. Charge the unit until the green FULL LED indicator flashes. Continue to  
recharge for one to two hours, then disconnect the Charging Adapter. The AC  
recharge system is an automatic taper charge and can be left connected to the main  
unit for long periods (the unit cannot be “overcharged” using this method).  
Ba tte ry Disp o sa l  
Contains a maintenance-free, sealed, non-spillable, lead acid  
battery, which must be disposed of properly. Recycling is  
required — contact your local authority for information. Failure  
to comply with local, state and federal regulations can result in  
fines or imprisonment. For more information on recycling this  
battery, call toll-free (800) 822-8837.  
1 2 Vo lt DC Ch a rg in g / Re ch a rg in g  
Charging the Jump-Starter/ Inflator from an external 12 volt DC power source  
requires the use of the 12 Volt DC adapter. This adapter has a male DC connector  
at each end.  
WARN IN GS  
Unlike the AC recharge method, DC recharge does NOT automatically activate the  
Battery Status LED display. Battery status can still be monitored by pressing the  
battery status level pushbutton.  
Do n o t d isp o se o f th e b a tte ry in fire , a s th is m a y re sult in a n e x p lo sio n .  
Be fo re d isp o sin g o f th e b a tte ry, p ro te ct e x p o se d te rm in a ls w ith h e a vy-  
d uty e le ctrica l ta p e to p re ve n t sh o rtin g (sh o rtin g ca n re sult in in jury  
o r fire ).  
WARN IN GS  
• DO NO T ch a rg e usin g th e 1 2 vo lt DC m e th o d fo r m o re th a n 4 h o urs  
m a x im um .  
Do n o t e x p o se b a tte ry to fire o r in te n se h e a t, a s it m a y e x p lo d e .  
6