WH/WIH/WIHL
Service and Installation Manual
Please read this manual completely before attempting to install or operate this equipment!
Notify carrier of damage! Inspect all components immediately. See page 1.
Drop-in Hot Pans
Effective Date: 2020
IMPORTANT INFORMATION
READ BEFORE USE
Specifications subject to change without notice.
Project: ___________
Item No.:ꢀ ___________
Quantity:ꢀ ___________
DROP-IN SERVING EQUIPMENT
WH-2
HOT PAN
Electrically Heated
Single Control
WH-3
WH-4
WH-5
WH-6
WH-3
SPECIFICATIONS
STANDARD FEATURES
TOP: Constructed of 18 gauge, type 304 stainless steel, die
stamped flange with a raised perimeter bead. There shall be
a solid vinyl gasket under the beaded edge to form a seal to
the counter top, thus preventing seepage or marring of the
counter top. Embossed mounting lugs are provided along the
inner surface of the top to hold the removable separator
channels in place.
g
Fully insulated to retain heat - protects fixtures and
saves energy
g
g
g
Open Bain Marie construction
Thermostatically controlled
Factory applied gasket - makes installation a snap and
seals units to the counter top, thus eliminating seepage
Accommodates standard 12” X 20” pans with the use
of separator channel(s), or fractional size pans with
the use of optional adapter bars
Wet or Dry Operation
1-Year Parts & Labor Warranty
UL Listed, ETLꢀListed
g
LINER: The inner liner shall be 18 gauge, type 304 stainless
steel, one piece construction, all welded ground and polished
to a uniform finish. All corners are coved with a minimum 1/4"
radius. A 3/4" dia. drain, with strainer, brass nipple, and valve
is provided.
g
g
g
INSULATION: The pan is fully insulated with high density
fiberglass insulation, 1" thick on all sides, 2" thick on the bot-
tom and enclosed by a 22 gauge galvanized steel outer case.
ACCESSORIES
g
g
Stainless steel adapter bars (pgs. DI-51-52)
Stainless steel adapter plates (pgs. DI-51-52)
ELECTRICAL: The unit is provided with individual 850 watt
heating elements, pre-wired to a single thermostat control
with a pilot light. A 6’ long, 3-wire cord and plug is provided,
extending from the control box located under the unit, on
operator's left. Bottom of outer case can be removed for ac-
cess to electrical components. Available for single phase
power only.
g CP - Cover Plate with handles, S/S
g
RDVE - Rear Drain Valve Extension (1) required
RT-1 - Remote Thermostat for counter installation, 24”
g
long
g
RTL-1 - Remote Thermostat for counter installation,
50” long
MS - Master on/off switch
g AF - Automatic water fill
Specifications subject to change without notice.
g
*Please see Operation &ꢀInstallation Manual for ALL operation and maintenance details.
DI-1
A
12”
12”
24”
PLAN VIEW
REMOVABLE SEPARATOR
CHANNEL
19-7/8” ID
6” ID
9”
2-5/8”
3-3/4”
2-1/2”
ELEVATION
END VIEW
7-1/4”
4-1/8”
3-3/4”
Electrical Characteristics
NEMA
# PLUG
MODEL WATTAGE VOLTAGE/KW/AMPS
5-20P
6-15P
6-15P
120V - 1.7KW - 14.2
COUNTER
WH-2
850WATT
208V - 1.7KW - 8.2
240V - 1.7KW - 7.1
CUT-OUT
SHIP WT.
MODEL
“A”
PAN SIZE
(REQUIRED)
W X L
(LBS.)
5-30P
6-15P
6-15P
120V - 2.0KW 16.7
208V - 2.0KW - 9.6
240V - 2.0KW - 8.3
1000WATT
850WATT
WH-2
29-3/4”
19-7/8” X 25-1/2” X 6”
22-1/4” X 28”
116
(75.5cm) (50.4 X 64.7 X 15.2cm) (56.5 X 71.1cm) (52.6kg)
5-30P
L6-20P
6-15P
120V - 2.55KW - 21.3
208V - 2.55KW - 12.3
240V - 2.55KW - 10.6
WH-3
WH-4
WH-3
WH-4
WH-5
WH-6
43-1/2”
19-7/8” X 39-1/4” X 6” 22-1/4” X 41-3/4”
(110.4cm) (50.4 X 99.6 X 15.2cm) (56.5 X 106cm) (67.1kg)
148
57-1/4” 19-7/8” X 53” X 6” 22-1/4” X 55-1/2” 174
5-50P
L6-20P
L6-20P
L6-30P
L6-20P
120V - 3.0KW - 25.0
208V - 3.0KW - 14.4
240V - 3.0KW - 12.5
208V - 3.4KW - 16.4
240V - 3.4KW - 14.2
1000WATT
850WATT
(145.4cm) (50.4 Xꢀ134.6 Xꢀ15.2cm) (56.5 X 140cm) (78.9kg)
71” 19-7/8” X 66-3/4” X 6” 22-1/4” X 69-1/4” 210
(180.3cm) (50.4 X 169.5 X 15.2cm) (56.5 Xꢀ175.8cm) (95.3kg)
84-3/4” 19-7/8” X 80-1/2” X 6” 22-1/4” X 83” 227
(215.2cm) (50.4 Xꢀ204.4 Xꢀ15.2cm) (56.5 Xꢀ210.8cm) (102.9kg)
L6-30P
L6-30P
208V - 4.0KW - 19.2
240V - 4.0KW - 16.7
1000WATT
850WATT
1000WATT
850WATT
1000WATT
Note: Numeral following the model letters denotes the 12X20 pan capacity
L6-30P
L6-30P
208V - 4.25KW - 20.4
240V - 4.25KW - 17.7
WH-5
WH-6
L6-30P
L6-30P
208V - 5.0KW - 24.0
240V - 5.0KW - 20.8
6-50P
L6-30P
208V - 5.1KW - 24.5
240V - 5.1KW - 21.3
6-50P
6-50P
208V - 6.0KW - 28.8
240V - 6.0KW - 25.0
Atlas Metal Industries 1135 NWꢀ159th Dr. Miami, FL 33169 (800) 762-7565 Fax: (305) 623-0475 atlasfoodserv.com
2/20-sc
DI-2
Project: ___________
Item No.:ꢀ ___________
Quantity:ꢀ ___________
DROP-IN SERVING EQUIPMENT
WIH-1
WIH-2
HOT PAN
WIH-3
WIH-4
WIH-5
WIH-6
Electrically Heated
Individual Controls
WIH-3
SPECIFICATIONS
STANDARD FEATURES
g
g
g
Fully insulated to retain heat - protects fixtures and
saves energy
TOP: Constructed of 18 gauge, type 304 stainless steel, die
stamped with a raised perimeter bead. There shall be a solid
vinyl gasket under the beaded edge to form a seal to the
counter top, thus preventing seepage or marring of the
counter top.
Individual thermostat controls - the operator can
control the temperature of each well separately
Factory applied gasket - makes installation a snap
and seals units to the counter, thus eliminating
seepage
Accommodates standard 12”x20” pans, or fractional
size pans with the use of optional adapter bars
Wet or Dry Operation
HOT FOOD WELLS: Individual hot food wells shall be 18
gauge, type 304 stainless steel, one piece construction, all
welded, ground and polished to a uniform finish. All corners
are coved with a minimum 1/4" radius. Each well is provided
with an 850 watt heating element (1000 watt on the WIH-1).
g
g
g
g
1-Year Parts & Labor Warranty
UL Listed, ETLꢀListed
INSULATION: The pan is fully insulated with high density
fiberglass, 1" thick on all sides, 2" thick on the bottom and en-
closed with a 22 gauge galvanized steel outer case.
ACCESSORIES
g
g
g
Stainless steel adapter bars (pg DI-51-52)
Stainless steel adapter plates (pg DI-51-52)
CP - Cover Plate with handles, S/S
ELECTRICAL: The unit is provided with an individual
thermostat control with a pilot light for each well. All heating
elements and controls are pre-wired, and a 6' long, 3-wire
cord and plug is provided, extending from the control box
located under the unit, on operator's left. Bottom of outer
case can be removed for access to electrical components.
g D - Individual Drain and Valve for each well (3/4” dia.
drain)
g
DM - Individual Drain for each well with manifold to
single valve
g
DMV - Individual Drain with valve for each well with
Specifications subject to change without notice.
manifold to single valve
g
DME - Individual drain for each well with manifold to
single valve w/ rear extension
g
RDVE - Rear Extension for D, DM, & DMV (1)
required
g RT - Remote Thermostats for counter installation, 24”ꢀ
long
g RTL - Remote Thermostats for counter installation, 50”
long
g MS - Master on/off switch
g AFꢀ- Automatic water fill (NOTE: DM required for water
fill)
*Please see Operation &ꢀInstallation Manual for ALL operation and maintenance details.
DI-3
A
24”
SHOWN WITH OPTIONAL DME -
DRAIN AND MANIFOLD WITH
REAR EXTENSION
PLAN VIEW
19-7/8” ID
6” ID
9”
3-3/4”
5-1/4”
7-1/2”
ELEVATION
END VIEW
2-1/8”
Electrical Characteristics
NEMA #
PLUG
5-15P
6-15P
6-15P
MODEL WATTAGE VOLTAGE/KW/AMPS
120V - 1.0KW -8.3
WIH-1
1000WATT
208V - 1.0KW - 4.8
240V - 1.0KW - 4.2
COUNTER
CUT-OUT
(REQUIRED)
W X L
22-1/4” X 14-1/4”
(56.5 X 36.8cm)
CONTROL
PANEL
SHIP WT.
(LBS.)
120V - 1.7KW - 14.2
208V - 1.7KW - 8.2
240V - 1.7KW - 7.1
120V - 2.0KW - 16.7
208V - 2.0KW - 9.6
240V - 2.0KW - 8.3
120V - 2.55KW - 21.3 L5-30P
208V - 2.55KW - 12.3
240V - 2.55KW - 10.6
120V - 3.0KW - 25.0
208V - 3.0KW - 14.4
240V - 3.0KW -12-5
208V - 3.4KW - 16.4
240V - 3.4KW - 14.2
208V - 4.0KW - 19.2
240V - 4.0KW - 16.7
208V - 4.25KW - 20.4 L6-30P
240V - 4.25KW - 17.7
208V - 5.0KW - 24.0
240V - 5.0KW - 20.8
208V - 5.1KW - 24.5
240V - 5.1KW - 21.3
5-20P
6-15P
6-15P
L5-30P
6-15P
6-15P
MODEL
“A”
WIH-2
850WATT
1000WATT
850WATT
1000WATT
850WATT
CUT-OUT
(IF REQUIRED)
4-1/2” X 6-1/4”
(11.4 X 15.8cm)
4-1/2” X 12-1/4”
(11.4 x 31.1cm)
4-1/2” X 26”
(11.4 Xꢀ66cm)
WIH-1
16”
(40.6cm)
41
(18.5kg)
112
(50.8kg)
152
(68.9kg)
WIH-2 29-3/4”
22-1/4” X 28”
(56.5 Xꢀ71.1cm)
22-1/4” X 41-3/4”
(110.4cm) (56.5 X 111.1cm)
(75.5cm)
WIH-3
WIH-4
L6-20P
6-15P
5-50P
L6-20P
L6-20P
L6-30P
L6-20P
L6-30P
L6-30P
WIH-3 43-1/2”
WIH-4 57-1/4”
22-1/4” X 55-1/2”
(145.4cm) (56.5 X 140.9cm) (11.4 X 100.9cm)
4-1/2’ X 39-3/4”
188
(85.3kg)
225
(102kg)
268
(121.5kg)
WIH-5
71”
(180.3cm) (56.5 X 175.8cm) (11.4 X 135.8cm)
WIH-6 84-3/4” 22-1/4” X 83” 4-1/2” X 67-1/4”
(213.3cm) (56.5 X 210.8cm) (11.4 X 170.8cm)
22-1/4” X 69-1/4”
4-1/2” X 53-1/2”
1000WATT
850WATT
1000WATT
850WATT
1000WATT
Note: Numeral following the model letters denotes the 12X20 pan capacity
WIH-5
WIH-6
L6-30P
L6-30P
L6-30P
6-50P
L6-30P
6-50P
6-50P
208V - 6.0KW - 28.8
240V - 6.0KW - 25.0
Atlas Metal Industries 1135 NWꢀ159th Dr. Miami, FL 33169 (800) 762-7565 Fax: (305) 623-0475 atlasfoodserv.com
2/20-sc
DI-4
Project: ___________
Item No.:ꢀ ___________
Quantity:ꢀ ___________
SLIM-LINE DROP-IN SERVING EQUIPMENT
SLIM-LINE
WIHL-2
HOT PAN
WIHL-3
Electrically Heated
Individual Controls
WIHL-4
WIHL-2
SPECIFICATIONS
STANDARD FEATURES
g
g
g
g
TOP: Constructed of 18 gauge, type 304 stainless steel, die
stamped with a raised perimeter bead. There shall be a solid
vinyl gasket under the beaded edge to form a seal to the
counter top, thus preventing seepage or marring of the
counter top.
Slim line configuration - it can install in counters only
16” wide
Fully insulated to retain heat - protects fixtures
and saves energy
Individual thermostat controls - the operator can
control the temperature of each well separately
Factory applied gasket - makes installation a snap and
seals units to the counter top, thus eliminating
seepage
HOT FOOD WELLS: Individual hot food wells shall be 18
gauge, type 304 stainless steel, one piece construction, all
welded, ground and polished to a uniform finish. All corners
are coved with a minimum 1/4" radius. Each well is provided
with an 850 watt heating element.
g Accommodates standard 12”ꢀX 20” pans, or fractional
size pans with the use of optional adapter bars.
Wet or Dry Operation
1-Year Parts & Labor Warranty
INSULATION: The pan is fully insulated with high density
fiberglass insulation, 1" thick on all sides, 2" thick on the
bottom, and enclosed by a 22 gauge galvanized steel outer
case.
g
g
g
UL Listed, ETAL LCisCtedESSORIES
ELECTRICAL: The unit is provided with an individual
thermostat control and pilot light for each well. All heating
elements and controls are pre-wired, and a 6' long, 3-wire
cord and plug is provided, extending from the control box
located under the unit, on operator's left. Bottom of outer
case can be removed for access to electrical components.
g
Stainless steel adapter bars (pg DI-51-52)
g
Stainless steel adapter plates (pg DI-51-52)
g
CPL - Cover Plate with handles, S/S
g D - Individual Drain and Valve for each well (3/4” dia.
drain)
g
DM - Individual Drain for each well with manifold to
single valve
Specifications subject to change without notice.
g
DMV - Individual Drain with valve for each well with
manifold to single valve
g
DME - Individual drain for each well with manifold to
single valve w/ rear extension
g
RDVE - Rear Extension for D, DM, DMV & DME (1)
required
g RT - Remote Thermostats for counter installation, 24”ꢀ
long
g RTL - Remote Thermostats for counter installation, 50”
long
g MS - Master on/off switch
g AFꢀ- Automatic water fill (NOTE: DM required for water
fill)
*Please see Operation &ꢀInstallation Manual for ALL operation and maintenance details.
DI-5
A
11-7/8” ID
6”
9”
16”
3-3/4”
2-1/2”
3-3/4”
10-1/4”
PLAN VIEW
ELEVATION
END VIEW
Electrical Characteristics
NEMA
# PLUG
MODEL WATTAGE VOLTAGE/KW/AMPS
120V - 1.7KW - 14.2 5-20P
WIHL-2 850WATT
1000WATT
208V - 1.7KW - 8.2
6-15P
COUNTER
CUT-OUT
CONTROL
240V - 1.7 KW - 7.1 6-15P
120V - 2.0KW - 16.7 5-30P
SHIP
WT.
PANEL
CUT-OUT
MODEL
“A”
(REQUIRED)
W X L
208V - 2.0KW - 9.6
240V - 2.0KW - 8.3
6-15P
6-15P
(LBS.)
(IF REQUIRED)
120V - 2.55KW - 21.3 5-30P
208V - 2.55KW - 12.3 L6-20P
240V - 2.55KW - 10.6 6-15P
120V - 3.0KW - 25.0 5-50P
208V - 3.0KW - 14.4 L6-20P
240V - 3.0KW - 12.5 L6-20P
208V - 3.4KW - 16.4 L6-30P
240V - 3.4KW - 14.2 L6-20P
46”
14-1/4” X 44-1/4” 4-1/2” X 12-1/4”
(116.8cm) (36.8 X 113.6cm) (11.4 Xꢀ31.1cm) (53.5kg)
118
WIHL-2
WIHL-3
WIHL-4
WIHL-3 850WATT
1000WATT
67-3/4”
14-1/4” X 66”
4-1/2” X 26”
176
(172cm) (36.8 X 167.6cm) (11.4 Xꢀ66cm) (79.8kg)
89-1/2” 14-1/4” X 87-3/4” 4-1/2” 39-3/4” 210
(227.3cm) (36.8 Xꢀ222.8cm) (11.4 X 100.9cm) (95.2kg)
WIHL-4 850WATT
1000WATT
Note: Numeral following the model letters denotes the 12X20 pan capacity
208V - 4.0KW - 19.2 L6-30P
240V - 4.0KW - 16.7 L6-30P
Atlas Metal Industries 1135 NWꢀ159th Dr. Miami, FL 33169 (800) 762-7565 Fax: (305) 623-0475 atlasfoodserv.com
2/20-sc
DI-6
WH/WIH/WIHL
----------------------------------------------------------------------------------------------------------------------------------------------------------
INSTALLATION
Provide the correct counter cut-out opening and drop in. The vinyl gasket assures complete seating. A non-
toxic silicone seal may be used between the gasket and counter top (not required). The unit is supplied
with a power cord and NEMA plug. Refer to the data plate on the control panel for the amperage and
voltage information. Use a licensed electrician when installing power source.
* Control box on 14 1/4" side.
---------------------------------------------------------------------------------------------------------------------------------------------------------
OPERATION
During operation the unit must be used with water and the thermostat must be set at position
#10. The thermostat dial has an off position and is numbered 1 to 10 (Number 10 is the
highest and mandatory setting for operation).
--------------------------------------------------------------------------------------------------------------------------------
MAINTENANCE
NEVER CLEAN PANS WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER
CLEANING COULD SCAR, MARK AND/OR CORRODE PANS. DO NOT USE STEEL WOOL OR
ABRASIVE PRODUCTS.TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO
REMOVE ALL RESIDUES. FAILURE TO MEET THESE CONDITIONS WILL VOID
WARRANTY.
--------------------------------------------------------------------------------------------------------------------------------
Subsidiary of Mercury Aircraft, Inc.
1135 N.W. 159th DR., MIAMI, FL 33169
PHONE (305) 625-2451, (800) 762-7565, FAX (305) 623-0475, E-mail: [email protected]
WIH-REMOTE INSTALLATION
PANEL WITH CUT-OUT
WH/WIH STANDARD INSTALLATION
STUDS
1
3 "
8
GALVANIZED BOX
SCREW
1
1
3 "
4
4 "
3
5 "
4
4
DIAL
FRONT FACE
NUTS
3
1 "
INSTALLATION OF THE REMOTE CONTROL HOT UNIT8S
.
---------------------------------------------------------------------------------------------------------------------------------------
Provide the correct Cut-Out opening for the remote control panel (see chart below).
Remove control box from the bottom of the unit.
1) Remove black control dial from front of control panel by loosening screws.
2) Remove 6/32 fiber nuts from the back of the control box.
3) Mount the S/S front plate to the Cut-Out in apron.
4) Attach the galvanized box to the S/S front plate.
The unit is ready to be connected to the electrical receptacle. Refer to the data plate on the control panel for the
amperage and voltage information. Use a licensed electrician when installing power source.
MODEL
CUT-OUT SIZE
4 1/2 x 6 1/4
4 1/2 x 12 1/4
4 1/2 x 26
4 1/2 x 39 3/4
4 1/2 x 53 1/2
4 1/2 x 67 1/4
1
2
3
4
5
6
CAUTION: HANDLE CONTROL PANEL & CONDUIT CAREFULLY,THERMOSTAT CAPILLARY TUBE IS VERY FRAGILE, IF
BROKEN, HEATING SYSTEM WILL NOT OPERATE.
FAILURE TO MEET THESE CONDITIONS WILL VOID WARRANTY.
Subsidiary of Mercury Aircraft, Inc.
1135 N.W. 159th DR., MIAMI, FL 33169
PHONE (305) 625-2451, (800) 762-7565, FAX (305) 623-0475, E-mail: [email protected]
PARTS LIST ELECTRICAL HEATED UNITS
W/AUTOMATIC WATER FILL
WH/ WIHD&M/ WIHLD&M- /WIHD&M- 1-6 SERIES
2
1
32
44
46
31
33
3
45
38
36
35
34
40
43
4
42
41
37
24
39
ITEM
NUMBER
PART
ITEM
NUMBER NUMBER
PART
DESCRIPTION
Vinyl Bead Gasket
Perforated Snap in Drain
Dial
DESCRIPTION
NUMBER
7002-0+Model #
86-3202
1097-2
25
26
27
28
29
30
31
32
33
34
35
36
12-228
1022
Plug 20Amp 240V
Plug 30Amp 240V
Plug 30Amp 120V
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
12-256
1012-101
1014-101
1001-1
48-22
S84553
51-25
2050
#12 Green Wire (Ground)
#14 Green Wire (Ground)
50 Amp Cord & Plug
S/S 10 x 1/2 Screws
Reservoir Assembly
1/4" x 3/8" NPT Male Conn.
Brass Flare Nut
1/4" Copper Tubing
1/4" x 1/4" Brass Union
Dual check vacuum breaker
#98d NPTM 1/4”
1100
3007-3
3016-11
1088-5
1089-2
Pilot Light
3/4" Brass Nipple 7” long
Brass Gate Valve
P-136 Terminal (#22 & 18 wire)
P-151 Terminal (#10 & 12 wire)
P-144 Terminal (#14 & 16 wire)
S Screw Thermostat Mounting
Remote Thermostat with 48" Bulb
Remote Thermostat with 72" Bulb
12" Nickel Wire
1089-4
1098
2031
21-23
1096-60
1096-96
1012-100
1014-100
1096-36
S81113-2
SC0099-238
1053-HT
1054-HT
1055-HT
1056-HT
1057-HT
1058-HT
1002
37
600022-1
14" Nickel Wire
Thermostat
Element Holder
S/S Element Holder
120V-850W Element
208V-850W Element
240V-850W Element
120V-1000W Element
240V-1000W Element
208V-1000W Element
Power Cord 14/3
(BACK FLOW PREVENTION)
38
39
30-46
1800-3904
1800-3903
600002
1800-35
1800-39
90º Street Elbow
Solenoid Valve 120V
Solenoid Valve 240V
Brass In Line Strainer
Ball In Valve
Close Nipple
90º 1/2" to 1/4 Reducing
Elbow Brass
1/2 dia. Brass Pipe Threaded
Both Ends
1/8” Male to 1/4” female
reducer
40
41
42
43
44
87-69
87-70
24
1004
1004-4
Power Cord 12/3
Power Cord 10/3
45
46
87-68
1069-1
Switch
AUTOMATIC WATER FILLUNITS
WIH, WH AND WCMHP/RMHP SERIES
INSTALLATION
When installing water supply to the unit, the supply lines must be purged to remove particles from
damagingthesolenoidvalveoperation. Afactorysuppliedin‐linewaterstrainerisinstalled. However, it
is recommended the customer supply a primary water filtering system for protection.
*Note‐Atlas Metal Ind. Inc. is not responsible for routine maintenance of the strainer or customer
supplied water filter system.
*AtlasMetalIndustriesInc.recommendsthatallunitsinstalledtoawatersourceuseourAutofill
or any backflow protection of your choice. Please refer to your local code.
Any attempt to change or modify the Auto Fill system will void the warranty.
OPERATION
HEATING CYCLE
HEATING TO COOLING
1. Turn master switch to “OFF” position.
1. Turn master switch to “OFF” position
2. Close drain valve.
2. Remove serving pans.
3. Turn master switch to “ON” position.
3. Drain hot water completely.
4. Turn on Auto Fill.
4. Turn selector switch to “COLD”.
5. Fill unit, preferably with “HOT” water
5. Turn master switch to “ON”.
until heating element is completely
CAUTION: Unit is equipped with a safety
submerged (water must be level.)
device. The compressor will not turn until
WARNING: HEATING ELEMENT WILL
stainless liner temperature is at 120 degrees
BE DAMAGED IF NOT SUBMERGED AT
or below.
ALL TIMES DURING HEATING CYCLE!
6. For WCM‐HP Select desire cooling
6. Turn selector switch to “HOT”.
thermostat setting (1‐Cool, 7‐Coldest).
7. Select desired setting on heating
For RM‐HP, no setup necessary; Unit
thermostat dial (1‐Warm, 10‐Hot).
ships with factory temperature controls
8. Cover unit with serving pans. Unit will
complete.
be ready for serving in approximately
7. Cover unit with serving pans. Unit will
30 minutes.
cool down and be ready for serving in
OPERATOR MUST CHECK PERIODICALLY THAT
approximately 30 minutes
HEATING ELEMENT IS SUBMERGED.
*Unit is not intended to operate 24/7.
COOL TO HEAT
Follow same steps shown for heat cycle
AUTOMATIC WATER FILLUNITS
Factory water depth settings for A/F units are 3/8" from the bottom of the liner and f
*Note ‐ or WCM‐HP
and RM‐HP, water depth should be 4” from the bottom of the liner.
DO NOT manually add water to Auto‐fill units above water level mark, damage and leakage to the
Automatic sensor could result. As the water evaporates the pans will fill automatically.
If the orange warning light turns on, please turn off the unit and check that the autofill is
working properly.
It is recommended that the Auto Fill be in the off position when not in use.
Subsidiary of Mercury Aircraft, Inc.
1135 N.W. 159th DR., MIAMI, FL 33169
PHONE (305) 625-2451, (800) 762-7565, FAX (305) 623-0475, E-mail: [email protected]
Electric Hot Food Drop-In Trouble Shooting Guide
Symptom
Probable Cause
Unit not plugged in.
No power at receptacle.
Unit will not heat
Thermostat and or switch not in the on position.
Call factory for service at 1-800-762-7565
Thermostat’s not turned to the highest setting.
Food products not hot enough when placed in unit.
Food product not being stirred or rotated.
Food products not
hot enough.
Heat lamp or head strip over the food product is recommended.
Call factory for service at 1-800-762-7565.
NOTE:
Before starting any warranty repair work you must first call the factory for authorization.
Failure to do so can make you responsible for repair cost.
4
3
2
1
REVISION HISTORY
DESCRIPTION
CHANGE LABLES
REV
1
DATE
2/16/2012
B
B
1,000 OR
850 WATTS
ELEMENT
1,000 OR
850 WATTS
ELEMENT
G
G
T
K
W
W
L
H
A
A
B
W
2
2
1
1
WHT
12 AWG
RED
GROUND TO THE
CONTROL CASE
BLK
12 AWG
BLK
T
H
W
K
L
B
N
R
G
D
3
A
-
A
R
4
O
1
C
POWER
CORD
MATERIAL:
CATEGORY:
DRAWN BY:
DATE:
11/30/2010
L.AND
TOLERANCES
1135 NW 159TH DRIVE MIAMI, FLORIDA 33169
CHECKED BY: ----
BREAK ALL SHARP
DESCRIPTION:
THIS SHEET CONTAINS CONFIDENTIAL INFORMATION,
IMAGES AND TRADE SECRETS OF ATLAS
METALS, INC. ANY UNAUTHORIZED USE OR
DISCLOSURE OF ANY PORTION THEREOF IS STRICTLY
PROHIBITED. THIS WORK IS THE EXCLUSIVE PROPERTY
OF ATLAS METALS INDUSTRIES, INC.
ELECTRICAL SCHEMATIC
CORNERS.
PART TO BE FREE OF
BURRS.
XXX DECIMAL 0.015
SIZE:
PART NUMBER:
WH-2 120V
ANGULARITY
1
B
UNLESS SPECIFIED
ON DRAWING
UNLESS OTHERWISE SPECIFIED,
ALL DIMENSIONS ARE IN INCHES
ALL RIGHTS RESERVED.
SHEET No.
SCALE: ----
1 OF 1
1
4
3
2
4
3
2
1
REVISION HISTORY
DESCRIPTION
CHANGE LABLES
REV
1
DATE
2/16/2012
B
B
1,000 OR
850 WATTS
ELEMENT
1,000 OR
850 WATTS
ELEMENT
G
G
K
W
D
W
L
A
E
A
B
R
2
2
1
1
RED
12 AWG
RED
GROUND TO THE
CONTROL CASE
BLK
12 AWG
BLK
T
H
W
K
L
B
N
R
G
D
3
-
A
R
A
4
O
1
C
POWER
CORD
MATERIAL:
CATEGORY:
DRAWN BY:
DATE:
11/30/2010
L.AND
TOLERANCES
1135 NW 159TH DRIVE MIAMI, FLORIDA 33169
DESCRIPTION:
CHECKED BY: ----
BREAK ALL SHARP
THIS SHEET CONTAINS CONFIDENTIAL INFORMATION,
IMAGES AND TRADE SECRETS OF ATLAS
METALS, INC. ANY UNAUTHORIZED USE OR
DISCLOSURE OF ANY PORTION THEREOF IS STRICTLY
PROHIBITED. THIS WORK IS THE EXCLUSIVE PROPERTY
OF ATLAS METALS INDUSTRIES, INC.
ELECTRICAL SCHEMATIC
CORNERS.
PART TO BE FREE OF
BURRS.
XXX DECIMAL 0.015
SIZE:
PART NUMBER:
WH-2 208-240V
ANGULARITY
1
B
UNLESS SPECIFIED
ON DRAWING
UNLESS OTHERWISE SPECIFIED,
ALL DIMENSIONS ARE IN INCHES
ALL RIGHTS RESERVED.
SHEET No.
SCALE: ----
1 OF 1
1
4
3
2
4
3
2
1
REVISION HISTORY
DESCRIPTION
CHANGE LABLES
REV
1
DATE
2/16/2012
B
B
1,000 OR
850 WATTS
ELEMENT
1,000 OR
850 WATTS
ELEMENT
G
G
G
G
T
W
K
W
T
W
K
W
H
L
A
A
H
L
A
A
B
W
B
4
4
W
4
4
1
1
1
1
WHT
12 AWG
RED
RED
GROUND TO THE
CONTROL CASE
BLK
12 AWG
BLK
BLK
T
H
W
K
L
B
N
R
G
D
3
-
R
A
A
4
O
1
C
POWER
CORD
MATERIAL:
CATEGORY:
DRAWN BY:
DATE:
11/30/2010
L.AND
TOLERANCES
WIH
1135 NW 159TH DRIVE MIAMI, FLORIDA 33169
DESCRIPTION:
CHECKED BY: ----
BREAK ALL SHARP
THIS SHEET CONTAINS CONFIDENTIAL INFORMATION,
IMAGES AND TRADE SECRETS OF ATLAS
METALS, INC. ANY UNAUTHORIZED USE OR
DISCLOSURE OF ANY PORTION THEREOF IS STRICTLY
PROHIBITED. THIS WORK IS THE EXCLUSIVE PROPERTY
OF ATLAS METALS INDUSTRIES, INC.
ELECTRICAL SCHEMATIC
CORNERS.
PART TO BE FREE OF
BURRS.
XXX DECIMAL 0.015
SIZE:
PART NUMBER:
WIH-2 120V
ANGULARITY
1
B
UNLESS SPECIFIED
ON DRAWING
UNLESS OTHERWISE SPECIFIED,
ALL DIMENSIONS ARE IN INCHES
ALL RIGHTS RESERVED.
SHEET No.
SCALE: ----
1 OF 1
4
1
3
2
4
3
2
1
REVISION HISTORY
DESCRIPTION
CHANGE LABLES
REV
1
DATE
2/16/2012
B
B
1,000 OR
850 WATTS
ELEMENT
1,000 OR
850 WATTS
ELEMENT
G
G
G
G
K
W
D
W
K
W
D
W
L
A
E
A
L
A
E
A
B
R
B
4
R
4
4
4
1
1
1
1
RED
12 AWG
RED
RED
GROUND TO THE
CONTROL CASE
BLK
12 AWG
BLK
BLK
T
H
W
K
L
B
N
R
G
D
3
-
R
A
A
4
O
1
C
POWER
CORD
MATERIAL:
CATEGORY:
DRAWN BY:
DATE:
11/30/2010
L.AND
TOLERANCES
WIH
1135 NW 159TH DRIVE MIAMI, FLORIDA 33169
DESCRIPTION:
CHECKED BY: ----
BREAK ALL SHARP
THIS SHEET CONTAINS CONFIDENTIAL INFORMATION,
IMAGES AND TRADE SECRETS OF ATLAS
METALS, INC. ANY UNAUTHORIZED USE OR
DISCLOSURE OF ANY PORTION THEREOF IS STRICTLY
PROHIBITED. THIS WORK IS THE EXCLUSIVE PROPERTY
OF ATLAS METALS INDUSTRIES, INC.
ELECTRICAL SCHEMATIC
CORNERS.
PART TO BE FREE OF
BURRS.
XXX DECIMAL 0.015
SIZE:
PART NUMBER:
WIH-2 208-240V
ANGULARITY
1
B
UNLESS SPECIFIED
ON DRAWING
UNLESS OTHERWISE SPECIFIED,
ALL DIMENSIONS ARE IN INCHES
ALL RIGHTS RESERVED.
SHEET No.
SCALE: ----
1 OF 1
1
4
3
2
LIMITED WARRANTY
Atlas Metal Industries, Inc. warrants to the Purchaser of this product that the
same shall be free from defects in the workmanship and material for a period of
one year from the date of original installation of the equipment, but not to exceed
eighteen (18) months after date of shipment from factory. During this period of
time Atlas Metal Industries, Inc. will replace all defective parts and will pay for
authorized replacement labor. Replacement and installation of such parts and
labor shall be provided only upon prior written authority of Atlas Metal Industries,
Inc.
The Refrigeration warranty is for a twenty (20) month time period and includes
supplying the compressor at a no charge basis provided the damage to the
compressor was not caused by the customer or end user. Authorized
replacement labor will be paid for a period of one year from date of installation.
Freight costs for defective unit to and from Atlas Metal Industries, Inc. are not
included, and all defective parts must be returned to the factory freight prepaid
for evaluation. ALL WARRANTY LABOR MUST BE AUTHORIZED BY ATLAS
METAL INDUSTRIES, INC. PRIOR TO THE ACTUAL WORK BEING DONE.
This warranty does not apply to any equipment or any part thereof, which has
been subjected to shipping damage, improper voltage, alteration, abuse or
misuses, and does not cover loss of food, other products, or damage to property
due to mechanical or electrical malfunction.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE
DESCRIPTION OF THE FACE HEREOF. SELLER DISCLAIMS ANY IMPLIED
WARRANTY OF MERCHANTABILITY OF THE GOODS OR THE FITNESS OF
THE GOODS FOR ANY PURPOSE AND BUYER AGREES THAT THE GOODS
ARE SOLD “AS IS.”
WARRANTY INFORMATION
In order to have your invoice approved for
payment by the factory, please note the following:
_______________________________________________
An authorization number must be obtained from
the factory prior to performing any warranty
service.
_______________________________________________
Atlas Metal will not approve excessive labor due to poor
access to the unit being serviced. If design does not
allow reasonable access, contact the factory.
_______________________________________________
All travel time that exceeds 100 miles round trip
must be authorized by the factory.
_____________________________________________________________________________________
Thank You:
Warranty service Dept.
|