036-21031-004 Rev. A (0603)
DESCRIPTION
®
These high efficiency EFH Series heat pump units are the out-
door part of a versatile system designed to economically heat
and cool a home or small business. The compact design of these
outdoor units make them ideal for ground or roof installation. The
units contain enough refrigerant charge for the outdoor unit, a
matched indoor coil and 15 feet of interconnecting piping.
EFH heat pumps can be custom-matched with one of YORK's
two lines of evaporator blower sections, each designed to serve
a specific function. Electric heaters are available for both, in a
variety of sizes.
TECHNICAL GUIDE
For Add-On applications, the indoor coil may be applied in the
supply duct of a conventional gas, oil or electric furnace. The
heat pump will be the primary source of heat for the building with
the furnace operating only when the heating requirement
exceeds the capacity of the heat pump.
TM
STELLAR PLUS
12 SEER
WARRANTY
5-year limited parts warranty.
SPLIT-SYSTEM HEAT PUMPS
10-year limited compressor warranty.
MODELS:
E*FH018 Thru E*FH060
(1.5 THRU 5 NOMINAL TONS)
FEATURES
•
QUALITY COILS - The coil is constructed of copper tube and alumi-
num fins.
•
COIL PROTECTION - Coils are protected from damage by a polymer
mesh applied between the coil face, and a PVC coated steel coil
guard, or a polymer coil guard.
•
•
DURABLE FINISH - Cabinet is made of pre-painted steel. The pre-
treated flat galvanized steel provides a better paint to steel bond,
which resists corrosion and rust creep. Special primer formulas and
glossy earth tone finish insure less fading when exposed to sunlight.
LOWER INSTALLED COST - Installation time and costs are reduced
by the fully exposed refrigerant connections and the single panel cov-
ering of the electrical controls. The small base dimension means
smaller mounting pads or less materials required for mounting, lower-
ing installation costs.
•
•
COMPRESSOR - 2 - 5 ton models are equipped with scroll compres-
sors which are internally protected against high pressure and tempera-
ture. This is accomplished by the simultaneous operation of high
pressure relief valve and a temperature sensor which protect the com-
pressor if undesirable operating conditions occur. The compressor is
protected by a 10 year limited warranty.
COMPLETE SYSTEM CONTROL - These heat pump units utilize the
unique YorkGuard V microprocessor control system to provide optimal
comfort control and assure reliable operation. The YorkGuard V con-
trol system continuously monitors the space environment to maintain
optimum efficiency. It initiates defrost only when necessary to further
reduce heating costs and improve reliability. Supplemental heat can
only operate below the balance point and then only upon need. In the
event of improper operating conditions (high temperature and high
pressure), the YorkGuard V will shut the system down to extend the
life of the heat pump. Rapid cycling is prevented by use of an integral
anti-recycle timer. Loss of charge protection is provided by a discharge
temperature sensor and internal compressor overloads.
T
O
D
A
R
E
I
I
A
F
S
I
T
R
C
E
O
C
M
P
R
L
E
H
Y
E
R
Y
I
A
T
R
U
A
N
T
G
T
I
P
N
U
C
U
M
A
P
F
A
M
R
E
Q
T
U
N
I
P
E
M
0
O
This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.
Certification applies only
when the complete
system is listed
LISTED
with ARI.
•
•
Finally the YorkGuard V control provides system diagnostics to aid the
service technician, minimizing repair time and cost. The YorkGuard V
control even stores important information for use during servicing and
has a 5 year warranty.
Due to continuous product improvement, specifications
are subject to change without notice.
LOW OPERATING SOUND LEVEL - The discharge air from the top
mounted fan is blown up away from the structure and any landscaping
carrying the normal operating noise up away from the living area. The
rigid top panel effectively isolates any motor sound. Isolator mounted
compressor and the rippled fins of the condenser coil muffle the nor-
mal fan motor and compressor operating sounds.
up-to-date technical information.
Additional rating information can be found at
•
U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment certification pro-
gram, which is based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
036-21031-004 Rev. A (0603)
ADDITIONAL R-22 CHARGE / ORIFICE SIZE FOR VARIOUS MATCHED SYSTEMS
OUTDOOR UNIT
E4FH018 E4FH024 E4FH030 E4FH036 E4FH042 E5FH048 E4FH060
Orifice in OD Distributor
FACTORY CHARGE, LBS. - OZ.
ID Orifice included w/Instruction Package
INDOOR COIL
37
5 - 9
57
45
5 - 1
59
49
5 - 12
--
55
6 - 14
--
65
8 - 3
--
69
9-11
--
76
14 - 0
--
1
REQUIRED SYSTEM ORIFICE + ADDITIONAL CHARGE, OZ.
COIL ORIFICE
G1FA/G1UA024S14, 17
G1FA/G1UA030S14
59
65
57 + 4
57 + 6
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
1
701 + 0
701 + 2
701 + 0
1
G1FA/G1UA036S14
73
701 + 0
1
G1FA/G1UA036S17
G1FA/G1UA048S17
G1FA/G1UA048S21
73
84
84
--
--
--
--
--
--
--
--
701 + 0
--
--
--
--
--
--
--
1
1
1
--
702 + 0 702 + 0 703 + 0
1
1
1
1
G1FA/G1UA060S21, 24
G2FD024S(H)14, 17
G2FD030S(H)17
GFD035S(H)14
90
61
65
65
75
78
78
84
90
--
--
702 + 2 702 + 5 703 + 5 703 + 0
57 + 6
59 + 0
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
1
1
59 + 2
701 + 8
701 + 0
1
--
--
--
--
--
--
59 + 2
--
701 + 0
1
1
G2FD036S(H)17
G2FD042S(H)21
G2FD046S(H)17
G2FD048S(H)21, 24
G2FD060S(H)24
--
--
--
--
--
701 + 4 702 + 0
1
1
--
--
--
--
--
--
702 + 2 702 + 0
1
1
702 + 2 702 + 0
1
1
--
--
702 + 8 703 + 4
1
1
--
703 + 5 703 + 0
1
G2FD061SH24
G1HD024
90
59
--
--
59 + 1
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
703 + 8
--
--
--
--
--
--
--
--
1
G1HD036
69
--
--
701 + 4
G1HD048
81
--
--
--
--
--
G1HD060
93
--
--
F2RP/FP018
F2RP/FP024
F2RP/FP030
(53)
61
(55) +0
57 + 6
--
--
59 + 0
59 + 2
1
65
--
701 + 0
1
1
F2RP/FP036
F2RP/FP042
F2FP048
75
78
84
90
90
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
701 + 4 702 + 0
1
1
--
--
--
--
702 + 2 702 + 0
1
1
--
--
--
702 + 8 703 + 3
1
1
F2FP060
--
--
703 + 5 703 + 0
1
1
F2FV060
703 + 5 703 + 0
FOOTNOTES:
1. Verify the TXV kit and the additional charge required for the specific evaporator coil in the system using the table above.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refigerant for the condenser, the smallest evaporator and for 15 feet of intercon-
necting line tubing.
2. Verify the orifice size and the additional charge required for the specific evaporator coil in the system using the table above:
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge=Base Charge (as shipped) +adder for
evaporator +adder for line set.
5. If the orifice in the evaporator was changed verify the evaporator nameplate has been marked with the correct orifice size.
Unitary Products Group
3
036-21031-004 Rev. A (0603)
COOLING CAPACITY - With Air Handler Coils
AIR HANDLER
COOLING
UNIT
MODEL
1
COIL MODEL
NET MBH
ELECTRIC
HEAT KW
RATED
CFM
SEER
SEER
+ TXV
MODEL
W
EER
2
3
W/O TXV
TOTAL SENS.
1 Phase 12 SEER HP / N1AH / G2FD
N1AHB08
N1AHB08
N1AHB08
N1AHB08
N1AHB08
N1AHB12
N1AHB12
N1AHC16
N1AHC16
N1AHC16
N1AHD20
N1AHD20
N1AHD20
2,5,7.5,10
2,5,7.5,10
17
17
17
17
14
17
17
21
21
21
24
24
24
G2FD024(S,H)17
G2FD030(S,H)17
G2FD024(S,H)17
G2FD030(S,H)17
G2FD035(S,H)14
650
650
800
850
850
19.0
19.4
23.4
23.4
23.4
29.0
34.6
40.0
41.0
47.5
48.0
58.0
58.5
14.3
14.6
17.6
17.6
17.6
21.8
25.6
29.6
30.3
35.6
36.0
42.0
41.5
12.05
12.15
12.10
12.10
12.10
---
---
10.65
10.70
10.85
10.85
10.85
10.65
10.50
10.50
10.80
10.50
10.85
10.70
10.70
E4FH018
E4FH024
---
2,5,7.5,10
---
2,5,7.5,10
---
2,5,7.5,10
---
E4FH030
E4FH036
5,7.5,10,15,18
5,7.5,10,15,18
5,7.5,10,15,20
5,7.5,10,15,20
5.7.5,10,15,20
5.7.5,10,15,20,25,30
7.5,10,15,20,25,30
7.5,10,15,20,25,30
G2FD036(S,H)17 1000
G2FD036(S,H)17 1200
G2FD042(S,H)21 1400
G2FD048(S,H)21 1425
G2FD048(S,H)21 1600
G2FD060(S,H)24 1620
G2FD060(S,H)24 1850
12.40
12.00
12.00
12.40
12.00
12.40
12.00
12.20
--
--
E4FH042
E5FH048
E4FH060
--
--
--
--
G2FD061H24
1875
--
1 Phase 12 SEER HP / N1VS / G2FD
E4FH018
E4FH024
N1VSB12
N1VSB12
N1VSB12
N1VSB12
N1VSB12
N1VSC16
N1VSC16
N1VSC16
N1VSD20
N1VSD20
N1VSD20
5,7.5,10,15,18
5,7.5,10,15,18
17
17
17
17
17
21
21
21
24
24
24
G2FD024(S,H)17
G2FD024(S,H)17
650
800
19.4
24.0
29.0
29.2
35.0
40.5
41.5
48.0
49.0
60.5
59.0
14.3
18.0
21.8
21.9
25.9
30.0
30.7
36.0
36.8
42.9
41.5
13.35
14.00
---
---
11.70
12.00
11.20
11.40
11.20
11.20
11.40
10.50
10.80
11.60
11.90
---
5,7.5,10,15,18
G2FD030(S,H)17 1000
G2FD036(S,H)17 1000
G2FD036(S,H)17 1200
G2FD042(S,H)21 1400
G2FD048(S,H)21 1425
G2FD048(S,H)21 1600
G2FD060(S,H)24 1650
G2FD060(S,H)24 1850
13.00
13.50
12.80
12.80
13.50
13.40
13.80
13.00
12.60
E4FH030
E4FH036
E4FH042
5,7.5,10,15,18
---
5,7.5,10,15,18
--
5,7.5,10,15,20
--
5,7.5,10,15,20
--
5.7.5,10,15,20
---
E5FH048
E4FH060
5.7.5,10,15,20,25,30
7.5,10,15,20,25,30
7.5,10,15,20,25,30
---
--
G2FD061H24
1875
--
4,5
1 Phase 12 SEER HP / F2RP / FP / FV
F2RP/F2FP018
F2RP/F2FP024
F2RP/F2FP024
F2RP/F2FP030
F2RP/F2FP030
F2RP/F2FP036
F2RP036
5,8,10
5,8,10
18
18
18
18
18
21
18
21
21
24
24
24
24
24
24
--
--
--
--
---
---
--
--
--
--
--
--
--
--
--
650
650
18.0
19.0
23.4
23.8
28.2
29.0
34.6
34.6
40.0
41.0
47.0
48.5
47.5
57.0
59.0
13.5
14.3
17.6
17.9
21.2
21.8
25.6
25.6
29.6
30.3
35.3
36.4
35.6
42.2
43.0
12.00
12.50
12.00
---
---
10.75
10.50
10.35
10.55
10.30
10.30
10.60
10.50
10.40
10.80
10.45
11.60
10.35
10.40
11.60
E4FH018
E4FH024
E4FH030
E4FH036
E4FH042
---
5,8,10
800
---
5,8,10,15
5,8,10,15
5,8,10,15
5,8,10,15
5,8,10,15
5,8,10,15
10,15,20,25
10,15,20,25
10,15,20,25
10,15,20,25
10,15,20,25
10,15,20,25
800
12.50
12.00
12.00
12.10
12.10
12.00
12.40
12.00
13.00
12.00
11.60
13.00
1035
1035
1250
1250
1400
1600
1600
1600
1600
1850
1875
---
---
--
F2RP042
--
F2RP042
--
F2FP048
--
F2FP048
---
E5FH048
E4FH060
F2V060
---
F2FP060
---
F2FP060
--
F2FV060H24
--
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input
in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same.
5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.
- = Not applicable
4
Unitary Products Group
036-21031-004 Rev. A (0603)
COOLING CAPACITY - With Upflow, Downflow and Horizontal Furnace and Coils
FURNACE**
COOLING
UNIT
MODEL
COIL
MODEL
NET MBH
TOTAL
NOMINAL
RATED
CFM
SEER
W/O TXV
1
W
SEER + TXV
EER
AIRFLOW
SENS.
14.1
14.3
14.1
14.3
14.3
14.4
14.4
16.7
16.7
16.8
16.8
17.7
17.7
17.7
17.7
21.2
21.2
21.6
21.2
21.2
21.2
21.2
21.5
21.6
21.6
25.9
26.2
25.9
26.2
26.2
26.2
25.8
25.9
30.0
30.0
30.0
30.0
29.6
30.0
30.3
34.9
35.6
34.9
35.6
35.6
36.0
41.0
41.0
42.0
41.5
14,17
14
G1FA024S14,17
G1FA030S14
650
650
18.8
19.0
18.8
19.0
19.0
19.2
19.2
22.2
22.2
22.4
22.4
23.6
23.6
23.6
23.6
28.2
28.2
28.8
28.2
28.2
28.2
28.2
28.6
28.8
28.8
35.0
35.4
35.0
35.4
34.6
34.6
34.8
35.0
40.5
40.5
40.5
40.5
40.0
40.5
41.0
46.5
47.5
46.5
47.5
47.5
48.0
57.0
57.0
58.0
58.5
12.00
-
10.55
10.65
10.55
10.65
10.65
10.70
10.70
10.85
10.85
11.00
11.00
10.85
10.85
11.00
11.00
10.35
10.35
10.30
10.35
10.35
10.35
10.35
10.35
10.65
10.65
10.60
10.70
10.60
10.70
10.50
10.50
10.55
10.60
10.65
10.70
10.65
10.70
10.50
10.65
10.80
10.45
10.60
10.45
10.60
10.50
10.80
10.40
10.40
10.70
10.70
12.50
-
14,17
14
G1UA024S14,17
G1UA030S14
650
12.00
-
575
725
E4FH018S06
650
12.50
-
14,17
17
G2FD024S14,17
G2FD030(S,H)17
G2FD035(S,H)14
G1FA030S14
650
12.50
-
650
12.50
-
14
650
12.50
-
14
800
-
12.00
12.00
12.10
12.10
-
G1UA030S14
800
-
17,21
G1FA036S17,21
G1UA036S17,21
G1HD024
800
-
800
-
725
925
E4FH024S06
-
17
17
14
14
17,21
-
820
12.10
G2FD024(S,H)14,17
G2FD030(S,H)17
G2FD035(S,H)14
G1FA036S14
820
12.10
-
820
12.10
-
820
12.10
-
1050
1050
1035
1050
1050
1050
1050
1050
1050
1050
1225
1225
1225
1225
1200
1200
1225
1225
1450
1450
1450
1450
1450
1450
1450
1600
1650
1600
1650
1600
1625
1850
1850
1800
1800
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.10
12.50
12.10
12.50
12.00
12.00
12.20
12.10
12.25
12.40
12.25
12.40
12.00
12.25
12.40
12.00
12.20
12.00
12.20
12.00
12.50
11.70
11.70
12.00
12.20
G1FA036S17,21
G1HD036
14
17,21
17
17
14
17
21
17
21
17
21
17
21
21
17
17
21
17
21
21
17
G1UA036S14
G1UA036S17,21
G2FD030(S,H)17
G2FD030(S,H)17
G2FD035(S,H)14
G2FD036(S,H)17
G2FD036(S,H)21
G1FA048S17
925
1175
E4FH030S06
G1FA048S21
G1UA048S17
G1UA048S21
1075
1375
E4FH036S06
G2FD036(S,H)17
G2FD036(S,H)21
G2FD042(S,H)21
G2FD046(S,H)17
G1FA048S17
G1FA048S21
G1UA048S17
1275
1625
E4FH042S06
G1UA048S21
G2FD042(S,H)21
G2FD046(S,H)17
21,24 G2FD048(S,H)21,24
21
G1FA048S21
G1FA060S21,24
G1UA048S21
21,24
21
1400
1800
E5FH048S06
E4FH060S06
21,24
G1UA060S21,24
21,24 G2FD048(S,H)21,24
24
21,24
21,24
24
G2FD060(S,H)24
G1FA060S21,24
G1UA060S21,24
G2FD060(S,H)24
G2FD061H24
1600
2100
24
1. TXV = Use 1TV700 Series Kit.
Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.
*
** Refer to Quick Selection Chart for specific furnace match-up.
Unitary Products Group
5
036-21031-004 Rev. A (0603)
HEATING PERFORMANCE - Air Handler and Multi-position Coils
2
3
ARI HEATING
OUTDOOR TEMP
17°F 27°F 37°F
MBH COP MBH COP STD. V. S. MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW
17 3.00 10 2.00 6.8 -- 1.3 7.8 1.27 10 1.35 12.3 1.60 15.2 1.6 17 1.61 17.6 1.66
19.5 3.20 11.3 2.10 7.5 -- 4.5 1.25
1.51
1
UNIT
MODEL
COIL
47 °F
17 °F
HSPF
-3 °F
7°F
47°F
57°F
MODEL
F2RP/F2FP018
F2RP/F2FP024
4
8
8
1.25 11.3 1.36 12.7 1.57 15.5 1.68 19.5 1.59 19.6 1.65
1.25 11.6 1.36 12.9 1.40 16.5 1.52 19.8 1.59 19.6 1.65
E4FH018 G2FD024(S,H)14,17 19.0 3.32 11.6 2.00 7.6
8
6
G2FD030(S,H)17 19.8 3.40 1.16 2.24 7.5 -- 6.2 1.52 8.2 1.23 11.6 1.69 12.8 1.38 16.4 1.5 19.8 1.79 19.6 1.63
G2FD035(S,H)14 19.8 3.40 1.16 2.24 7.5 -- 6.2 1.5 8.2 1.25 11.6 1.69 12.9 1.39 16.6 1.51 19.8 1.79 19.8 1.64
F2RP/F2FP024
F2RP/F2FP030
24 3.32 12.9 2.20
24 3.32 12.9 2.20
8
8
8
8
8
8
8
8
8
8
-- 6.6 1.55 11 1.78 12.9 1.7 16 1.85 18.8 1.87 24 1.8 26.6 2.07
-- 6.8 1.56 11.4 1.76 12.9 1.78 16.2 1.84 19 1.85 24 2.07 26.8 2.08
8.1 6.6 1.58 11.6 1.75 13.5 1.78 16.3 1.82 19.1 1.85 23.8 2.07 26.6 2.1
-- 6.8 1.6 11.4 1.73 13.6 1.75 16.2 1.80 19.2 1.83 24 2.08 26.8 2.08
-- 6.9 1.57 11.6 1.74 13.6 1.77 16.4 1.80 19.4 1.8 24 2.06 26.8 2.1
-- 9.6 1.98 13.1 2.1 16.6 2.21 20.3 2.33 24.3 2.46 28 2.56 32.9 2.7
-- 9.6 1.95 13.1 2.09 16.7 2.21 20.2 2.34 24.4 2.48 28 2.57 33 2.71
8.2 9.8 2.06 13.1 2.14 16.5 2.2 19.9 2.29 23.9 2.4 28 2.5 32.7 2.55
-- 9.4 2.06 13.2 2.14 16.6 2.3 20 2.31 24 2.41 28 2.6 33 2.6
8.2 9.9 2.02 13.3 2.15 16.6 2.19 21 2.41 23.8 2.4 28 2.6 33.4 2.65
E4FH024 G2FD024(S,H)14,17 23.8 3.40 13.5 2.30
G2FD030(S,H)17
G2FD035(S,H)14
24 3.26 13.6 2.18
24 3.26 13.6 2.18
28 3.33 17 2.33
28 3.33 17 2.33
28 3.33 17 2.33
28 3.33 17 2.33
F2RP/F2FP030
F2RP/F2FP036
E4FH030 G2FD030(S,H)17
G2FD035(S,H)14
G2FD036(S,H)17,21 28 3.33 17 2.33
F2RP/F2FP036
F2RP/F2FP042
36.0 3.10 21.8 2.30 8.0 -- 12.5 2.36 17.1 2.57 21.8 2.78 26.5 2.99 31.7 3.21 36.0 3.40 41.4 3.56
36.0 3.10 21.8 2.30 8.0 -- 12.5 2.35 17.2 2.57 21.8 2.78 26.4 2.99 31.6 3.21 36.0 3.40 41.5 3.57
E4FH036 G2FD042(S,H)21 36.0 3.38 21.8 2.26 8.0 -- 12.5 2.63 17.1 2.73 21.8 2.83 26.5 2.93 31.7 3.04 36.0 3.12 41.7 3.18
G2FD046(S,H)17 36.0 3.38 21.8 2.26 8.0 -- 12.5 2.63 17.2 2.73 21.8 2.83 26.4 2.93 31.7 3.04 36.0 3.12 41.4 3.16
G2FD036(S,H)17,21 36.0 3.40 21.8 2.28 8.0 8.1 12.5 2.60 17.1 2.70 21.8 2.80 26.5 2.90 31.7 3.02 36.0 3.10 41.7 3.16
F2RP/F2FP042
F2FP048
42.0 3.30 25.2 2.20 7.8 -- 13.4 3.08 19.3 3.22 25.2 3.36 31.1 3.50 37.7 3.63 42.0 3.73 48.5 3.85
42.0 3.58 25.2 2.32 8.0 -- 12.5 2.98 18.8 3.08 25.2 3.18 31.6 3.29 38.6 3.40 42.0 3.44 50.4 3.56
E4FH042 G2FD042(S,H)21 41.5 3.40 25.0 2.26 8.0 8.1 12.5 2.94 18.8 3.09 25.0 3.24 31.2 3.39 38.2 3.55 41.5 3.58 49.6 3.73
G2FD046(S,H)17 41.5 3.40 25.0 2.24 8.0 -- 13.4 3.05 19.2 3.16 25.0 3.27 30.8 3.38 37.3 3.51 41.5 3.58 47.8 3.66
G2FD048(S,H)21,24 42.0 3.58 25.2 2.32 8.0 8.0 12.4 2.98 18.8 3.08 25.2 3.18 31.6 3.29 38.7 3.41 42.0 3.44 50.4 3.56
F2FP048
F2FP060
47.5 3.30 28.4 2.20 8.1 --
47.5 3.30 28 2.20 8.1 --
17 3.54 22.6 3.66 28.4 3.78 34.2 3.91 39 3.76 47.5 4.03 53.5 4.13
18 3.5 22.8 3.58 28 3.75 34.6 3.95 40 3.8 47.5 4.15 54 4.3
E5FH048
G2FD048(S,H)21,24 48 3.48 28 2.34 8.1 8.2 17 3.52 22.6 3.6 28 3.76 34.2 3.96 40 3.9 48 4.04 53.5 4.25
G2FD060(S,H)24 48.5 3.30 28.4 2.20 8.1 8.2 18 3.55 22.8 3.65 28.4 3.78 34.6 3.96 40 3.8 48.5 4.03 54 4.26
F2FP060
F2FV060
60.0 3.40 40.0 2.40 8.0 -- 18.7 4.08 26.1 4.44 40.0 4.80 40.7 5.16 49.0 5.55 60.0 5.94 68.6 6.25
60.0 3.00 40.0 2.60 -- 8.3 17.6 3.93 24.6 4.11 40.0 4.29 38.6 4.47 46.6 4.68 60.0 4.93 66.1 5.07
E4FH060
G2FD060(S,H)24 60.0 3.50 40.0 2.50 8.2 8.3 18.9 3.94 26.0 4.21 40.0 4.48 40.0 4.75 48.1 5.05 60.0 5.39 67.8 5.61
G2FD061H24 62.0 3.60 41.0 2.60 8.4 20.2 4.07 26.9 4.28 41.0 4.49 40.5 4.70 48.3 4.95 62.0 5.22 67.5 5.39
For Notes See Page 7.
–
6
Unitary Products Group
036-21031-004 Rev. A (0603)
HEATING PERFORMANCE - Furnace Coils
2
3
ARI HEATING
OUTDOOR TEMP
17°F 27°F
1
UNIT
COIL
47°F
17 °F
HSPF
-3 °F
7°F
37°F
47°F
57°F
MODEL
MODEL
MBH COP MBH COP STD. V. S. MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW
E*FH WITH (VARIABLE SPEED & STANDARD) FURNACE COILS
G1HD024
G1FA024S17
G1UA024S17
G1FA030S14
G1UA030S14
G1HD024
18 3.08 9.9 2.00 7.1
19.0 3.24 11.4 2.16 7.6
19.0 3.24 11.4 2.16 7.6
19.0 3.32 11.6 2.20 7.6
19.0 3.32 11.6 2.20 7.6
-- 6.2 1.1
9
1.15 9.9 1.25 13.6 1.4 16 1.5 18 1.6 20 1.75
-- 6.6 1.09 9.2 1.1 11.4 1.25 13.8 1.45 16.6 1.54 19.6 1.64 22 1.74
-- 6.6 1.09 9.2 1.1 11.4 1.25 13.8 1.45 16.6 1.54 19.6 1.64 22 1.74
-- 6.6 1.08 9.2 1.15 11.6 1.27 14.2 1.43 16.8 1.5 19.8 1.62 22.4 1.76
-- 6.6 1.08 9.2 1.15 11.6 1.27 14.2 1.43 16.8 1.5 19.8 1.62 22.4 1.76
-- 7.2 1.57 10 1.67 12.2 1.76 16.4 1.9 19.6 1.95 24 2.05 27.4 2.17
-- 7.6 1.5 10.4 1.65 13.4 1.76 16.6 1.85 19.8 1.97 23.6 2.03 27.6 2.16
-- 7.6 1.5 10.4 1.65 13.4 1.76 16.6 1.85 19.8 1.97 23.6 2.03 27.6 2.16
-- 7.6 1.52 10.4 1.6 13.6 1.76 16.8 1.9 20 1.9 24 2.03 28.2 2.18
-- 7.6 1.52 10.4 1.6 13.6 1.76 16.8 1.9 20 1.9 24 2.03 28.2 2.18
-- 9.8 2.08 13.1 2.14 16.6 2.1 19.8 2.2 23.8 2.38 28 2.5 39.8 2.55
E4FH018
E4FH024
E4FH030
24 3.16 12.2 2.00
23.6 3.16 13.4 2.14
23.6 3.16 13.4 2.14
24 3.26 13.6 2.18
8
8
8
8
8
8
8
8
8
8
G1FA030S17
G1UA030S17
G1FA036S17,21
G1UA036S17,21 24 3.26 13.6 2.18
G1HD036
G1FA036S14
G1UA036S14
G1FA036S17,21
28 3.33 17 2.3
28 3.33 17.2 2.3
28 3.33 17.2 2.3
28 3.33 17.2 2.3
--
--
10 2.07 13.2 2.15 16.8 2.3 19.9 2.3 23.9 2.39 28 2.5 34 2.57
10 2.07 13.2 2.15 16.8 2.3 19.9 2.3 23.9 2.39 28 2.5 34 2.57
-- 10.1 2.08 13.3 2.17 17 2.4 20.1 2.4 24.1 2.4 28 2.55 34.2 2.6
-- 10.1 2.08 13.3 2.17 17 2.4 20.1 2.4 24.1 2.4 28 2.55 34.2 2.6
-- 12.8 2.61 17.3 2.69 21.8 2.78 26.3 2.86 31.3 2.95 35.6 3.02 41.2 3.07
-- 12.8 2.61 17.3 2.69 21.8 2.78 26.3 2.86 31.3 2.95 35.6 3.02 41.2 3.07
-- 12.5 2.63 17.2 2.73 21.8 2.83 26.4 2.93 31.7 3.04 36.0 3.12 41.4 3.16
-- 12.5 2.63 17.2 2.73 21.8 2.83 26.4 2.93 31.7 3.04 36.0 3.12 41.4 3.16
-- 12.5 2.98 18.9 3.09 25.2 3.21 31.5 3.33 38.5 3.47 42.0 3.52 50.3 3.66
-- 12.5 2.98 18.9 3.09 25.2 3.21 31.5 3.33 38.5 3.47 42.0 3.52 50.3 3.66
-- 13.4 3.05 19.2 3.16 25.0 3.27 30.8 3.38 37.3 3.51 41.5 3.58 47.8 3.66
-- 13.4 3.05 19.2 3.16 25.0 3.27 30.8 3.38 37.3 3.51 41.5 3.58 47.8 3.66
-- 16.1 3.23 22.1 3.41 28 3.57 34 3.72 40.6 3.91 48 4.06 54.8 4.16
-- 16.1 3.23 22.1 3.41 28 3.57 34 3.72 40.6 3.91 48 4.06 54.8 4.16
G1UA036S17,21 28 3.33 17.2 2.3
G1FA048S21
G1UA048S21
G1FA048S17
G1UA048S17
G1FA048S21
G1UA048S21
G1FA048S17
G1UA048S17
G1FA048S21
G1UA048S21
G1FA060S21,24
35.6 3.46 21.8 2.30 8.0
35.6 3.46 21.8 2.30 8.0
36.0 3.38 21.8 2.26 8.0
36.0 3.38 21.8 2.26 8.0
42.0 3.50 25.2 2.30 8.0
42.0 3.50 25.2 2.30 8.0
41.5 3.40 25.0 2.24 8.0
41.5 3.40 25.0 2.24 8.0
E4FH036
E4FH042
48 3.40 28 2.30
48 3.40 28 2.30
48 3.40 28 2.30
8
8
8
8
E5FH048
E4FH060
-- 16.2 3.24 22.2 3.42 28 3.55 34 3.7 40.6 3.92 48
-- 16.2 3.24 22.2 3.42 28 3.55 34 3.7 40.6 3.92 48
4
4
54.9 4.18
54.9 4.18
G1UA060S21,24 48 3.40 28 2.30
G1FA060S21,24 60.0 3.40 40.0 2.40 8.0
G1UA060S21,24 60.0 3.40 40.0 2.40 8.0
-- 18.9 3.95 26.0 4.21 33.0 4.48 40.1 4.74 48.1 5.04 57.0 5.39 67.8 5.60
-- 18.9 3.95 26.0 4.21 33.0 4.48 40.1 4.74 48.1 5.04 57.0 5.39 67.8 5.60
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental
electric heat operation.
3. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric
power input during the same period.
— = Not Applicable.
Unitary Products Group
7
036-21031-004 Rev. A (0603)
Room Thermostats - A wide selection of matching thermo-
stats is available to provide features required for any installa-
tion.
ACCESSORIES
Refer to Price Manual for specific model numbers.
Start Assist Kit (2SA067*)
2H/1C, manual change-over electronic non-programmable
thermostat.
Blower Time Delay - Available to increase efficiency when
installed. Installs on indoor section and maintains blower for
approximately one minute after cooling thermostat has been
satisfied.
3H/2C, non-programmable digital thermostat.
3H/2C, auto/manual changeover, electronic programmable,
7-day, thermostat.
Hard Start Kits - Provides required starting torque for use
with Thermal Expansion Valve Kit.
* For the most current accessory information, refer to the
price book or consult factroy.
Low Temperature Cutout (2LT06700224) - Prevents heat
SOUND BLANKET
pump operation below -10°F ambient temperature.
EFH
MODEL
018
SOUND RATING
Compressor Blanket - Designed to further reduce the nor-
mal operating sound.
DECIBELS
72
73
74
74
74
76
76
Add-on Control (2AC02700701) - Provides interface for use
of gas and oil furnaces with the heat pump system.
024
030
036
Thermal Expansion Valve Kit - 1TV0700 Series TXV kit
used to improve system performance.
042
048
Outdoor Thermostat (2TD06700124) - Provides additional
staging of supplemental electric heat.
060
*Rated in accordance with ARI Standard 270.
8
Unitary Products Group
036-21031-004 Rev. A (0603)
TYPICAL INSTALLATION
THERMOSTAT
WEATHERPROOF
DISCONNECT
SWITCH
TO
POWER
SUPPLY
48” OVERHEAD
CLEARANCE
TO
INDOOR
BLOWER
NEC
CLASS 1
WIRING
12” REAR AND
SIDES
NEC
CLASS 2
WIRING
TO COIL
24” SERVICE ACCESS
CLEARANCE
NOTE: All outdoor wiring must be weatherproof
Seal opening(s) with permagum
or equivalent
TYPICAL FIELD WIRING - (AIR HANDLER / ELECTRICAL HEAT)
ALL WIRING TO BE ACCORDANCE WITH NATIONAL CODE AND/OR LOCAL CODES.
INDOOR UNIT 3
OUTDOOR
THERMOSTAT
UNIT
ELECTRIC HEATER ACCESSORY
S1*
S2*
O
*
BONNET SENSOR
CONNECTIONS FOR
ADD-ON SYSTEM.
O
X or L
R
O
X or L
R
C
Y
R
B or C
Y
B or C
Y
W
W
G
G
W2/60
W1/66
W2
CONTACTOR
W1
GND.
SCREW
T2
L2
T1
L1
GND.
LUG
2 TERMINAL NOT USED ON ALL THERMOSTATS.
3 FOR TYPICAL FIELD WIRING WITH N*VS VARIABLE
SPEED AIR HANDLER, SEE N*VS INSTRUCTIONS.
4 CONNECT POWER WIRING TO TERMINAL BLOCK
ON UNITS WITHOUT ELECTRIC HEAT OR UNITS
WITHOUT ACIRCUIT BREAKER.
M
CIRCUIT
BREAKER4
POWER WIRING
208/230-1-60
POWER WIRING
POWER WIRING
208/230-1-60
24V CONTROL WIRING (NEC CLASS 2)
Unitary Products Group
9
036-21031-004 Rev. A (0603)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
INDOOR COIL MODEL NO.
E4FH018S06
F2RP/F2FP024
600
ID CFM
650
700
CONDENSER
ENTERING AIR
TEMPERATURE
ID DB (°F)
ID WB (°F)
T.C.
85
80
75
70
85
80
75
70
85
80
75
70
72
67
62
57
72
67
62
57
72
67
62
57
24.0
14.8
1.57
22.9
14.5
1.65
20.7
13.8
1.78
18.6
13.2
1.94
16.4
12.4
2.13
14.3
11.7
2.31
22.0
14.9
1.61
21.0
14.5
1.68
18.8
13.8
1.79
16.8
13.0
1.94
15.0
12.5
2.12
13.1
11.9
2.29
20.1
15.0
1.63
19.0
14.7
1.68
17.0
13.9
1.79
15.3
13.2
1.93
13.5
12.5
2.09
11.8
11.8
2.24
18.2
15.1
1.62
17.2
14.7
1.67
15.5
13.9
1.77
13.8
13.1
1.90
12.3
12.0
2.06
10.7
11.1
2.21
24.3
15.4
1.59
23.2
15.1
1.68
20.9
14.4
1.80
18.7
13.7
1.96
16.6
13.1
2.16
14.5
12.5
2.34
22.3
15.5
1.64
21.3
15.1
1.70
19.0
14.3
1.82
17.0
13.6
1.97
15.1
13.0
2.15
13.2
12.4
2.32
20.3
15.6
1.66
19.3
15.3
1.71
17.2
14.4
1.82
15.5
13.8
1.96
13.6
13.0
2.12
11.8
12.3
2.27
18.5
15.7
1.66
17.6
15.5
1.70
15.7
14.5
1.81
14.1
13.8
1.94
12.6
12.3
2.10
11.1
11.2
2.25
24.5
15.9
1.60
23.4
15.7
1.68
21.0
14.9
1.81
18.9
14.3
1.97
16.8
13.8
2.17
14.7
13.3
2.35
22.6
16.0
1.64
21.5
15.7
1.71
19.2
14.9
1.83
17.3
14.4
1.98
15.3
13.6
2.16
13.4
13.0
2.33
20.6
16.2
1.67
19.5
15.8
1.72
17.5
15.1
1.83
15.6
14.3
1.97
13.9
13.6
2.14
12.1
12.9
2.30
18.7
16.2
1.67
17.9
16.0
1.71
15.9
15.0
1.82
14.4
13.8
0.52
12.8
12.5
2.11
11.3
11.3
2.26
75
85
S.C.
K.W
T.C.
S.C.
K.W
T.C.
95
S.C.
K.W
T.C.
105
115
125
S.C.
K.W
T.C.
S.C.
K.W
T.C.
S.C.
K.W
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
T.C.
S.C.
KW
Air Handler
N1AHB08
Coil
G2FD024(S,H)17
G2FD030(S,H)17
G2FD024(S,H)17
1.00
1.02
1.02
0.95
0.99
0.99
1.00
1.00
1.00
1.02
1.02
0.99
0.99
1.00
1.00
1.02
1.00
0.94
0.99
0.99
1.00
1.00
1.00
1.02
1.02
0.99
0.99
1.00
0.94
1.00
0.94
0.94
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
N1AHB08
N1VSB12
F2RP/F2FP018
G1UA024S14
G1UA024S17
G2FD024(S,H)14
G2FD024(S,H)17
G1UA030S14
G2FD030(S,H)14
G2FD030(S,H)17
G1FA024S14
G1FA024S17
G1FA030S14
10
Unitary Products Group
036-21031-004 Rev. A (0603)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
INDOOR COIL MODEL NO.
E4FH024S06
F2RP/F2FP030
750
ID CFM
800
850
CONDENSER
ID DB (°F)
ID WB (°F)
T.C.
85
80
75
70
85
80
75
70
85
80
75
70
ENTERING AIR
TEMPERATURE
72
67
62
57
72
67
62
57
72
67
62
57
28.2
17.7
1.83
27.3
17.6
2.04
25.6
17.3
2.24
23.9
16.9
2.50
22.1
16.5
2.82
20.3
16.1
3.14
26.0
17.7
1.81
25.1
17.7
2.00
23.6
17.4
2.23
22.0
16.9
2.48
20.3
16.5
2.80
18.6
16.1
3.12
23.8
18.0
1.80
23.0
18.0
1.99
21.6
17.6
2.21
20.1
17.1
2.47
18.7
16.8
2.78
17.3
16.5
3.09
21.9
18.1
1.79
21.1
18.1
1.98
20.0
18.0
2.20
18.5
17.3
2.46
17.1
16.7
2.78
15.7
16.1
3.10
28.4
18.1
1.86
27.5
18.1
2.15
25.8
17.8
2.28
24.0
17.4
2.53
22.3
17.1
2.85
20.6
16.8
3.17
26.2
18.1
1.84
25.3
18.2
2.04
23.8
17.9
2.26
22.1
17.5
2.52
20.5
17.2
2.83
18.9
16.9
3.14
24.1
18.4
1.83
23.2
18.5
2.02
21.8
18.2
2.24
20.4
18.0
2.50
18.8
17.3
2.81
17.2
16.6
3.12
22.0
18.5
1.82
21.3
18.6
2.01
20.1
18.5
2.23
18.7
17.8
2.49
17.5
17.3
2.81
16.3
16.8
3.13
28.6
18.5
1.87
27.6
18.6
2.07
26.0
18.4
2.29
24.1
18.0
2.55
22.3
17.7
2.86
20.5
17.4
3.17
26.4
18.6
1.85
25.5
18.7
2.05
24.0
18.4
2.27
22.2
18.0
2.53
20.7
17.8
2.84
19.2
17.6
3.15
24.2
18.9
1.84
23.4
19.0
2.03
21.9
18.7
2.25
20.5
18.4
2.51
19.0
17.9
2.83
17.5
17.4
3.15
22.2
19.0
1.83
21.4
19.1
2.02
20.3
19.0
2.24
18.8
18.3
2.50
17.7
17.6
2.82
16.6
16.9
3.14
75
85
S.C.
K.W
T.C.
S.C.
K.W
T.C.
95
S.C.
K.W
T.C.
105
115
125
S.C.
K.W
T.C.
S.C.
K.W
T.C.
S.C.
K.W
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
T.C.
S.C.
KW
Air Handler
N1AHB08
Coil
G2FD024(S,H)17
G2FD030(S,H)17
G2FD035(S,H)14
G2FD024(S,H)17
0.98
0.98
0.98
1.01
0.98
0.98
0.98
0.98
0.97
1.00
1.00
0.98
0.98
0.97
1.00
1.00
0.98
0.98
0.98
1.01
0.98
0.98
0.98
0.98
0.97
1.00
1.00
0.98
0.98
0.97
1.00
1.00
0.96
0.96
0.96
0.87
0.96
0.96
0.96
0.96
0.96
0.96
0.96
0.96
0.96
0.96
0.96
0.96
N1AHB08
N1AHB08
N1VSB12
F2RP/F2FP024
G2FD024(S,H)14
G2FD024(S,H)17
G1HD024
G1UA030S14
G1UA036S17
G1UA036S21
G2FD030(S,H)17
G2FD035(S,H)14
G1FA030S14
G1FA036S17
G1FA036S21
Unitary Products Group
11
036-21031-004 Rev. A (0603)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
INDOOR COIL MODEL NO.
E4FH030S06
G2FD030(S,H)17
950
ID CFM
1050
1150
CONDENSER
ENTERING AIR
TEMPERATURE
ID DB (°F)
ID WB (°F)
T.C.
85
80
75
70
85
80
67
75
70
85
80
67
75
70
72
67
62
57
72
62
57
72
62
57
33.2
21.1
2.35
31.9
20.7
2.57
30.3
20.2
2.89
28.7
19.8
3.28
27.0
19.3
3.74
25.3
18.8
4.20
30.6
21.1
2.33
29.4
20.8
2.55
28.0
20.4
2.87
26.4
19.8
3.25
24.8
19.4
3.72
23.2
18.9
4.19
28.1
21.4
2.33
26.9
21.1
2.54
25.7
20.7
2.85
24.2
20.1
3.24
22.8
19.6
3.69
21.4
19.2
4.15
25.8
21.6
2.31
24.8
21.2
2.53
23.6
20.9
2.84
22.3
20.2
3.22
21.0
19.7
3.67
19.7
19.3
4.12
33.4
21.7
2.39
32.2
21.4
2.65
30.6
21.1
2.92
28.8
20.6
3.30
27.2
20.1
3.76
25.5
19.7
4.22
30.9
21.8
2.37
29.6
21.5
2.59
28.2
21.2
2.90
26.6
20.7
3.28
25.1
20.2
3.75
23.5
19.7
4.22
28.4
22.1
2.36
27.2
21.9
2.57
25.9
21.5
2.88
24.5
21.0
3.27
23.0
20.3
3.73
21.6
19.6
4.19
26.0
22.2
2.34
25.0
22.0
2.56
23.8
21.6
2.87
22.5
21.0
3.25
21.3
20.3
3.71
20.1
19.7
4.18
33.6
22.4
2.44
32.3
22.1
2.66
30.7
21.7
2.98
29.0
21.3
3.36
27.3
20.9
3.83
25.6
20.5
4.30
31.0
22.5
2.43
29.8
22.2
2.64
28.4
21.9
2.96
26.8
21.3
3.35
25.3
21.0
3.80
23.8
20.6
4.26
28.6
22.9
2.41
27.5
22.6
2.62
26.1
22.2
2.94
24.6
21.6
3.33
23.2
21.1
3.79
21.7
20.6
4.25
26.2
23.0
2.40
25.2
22.7
2.61
24.1
22.3
2.93
22.7
21.6
3.31
21.6
21.0
3.77
20.6
20.4
4.23
75
85
S.C.
K.W
T.C.
S.C.
K.W
T.C.
95
S.C.
K.W
T.C.
105
115
125
S.C.
K.W
T.C.
S.C.
K.W
T.C.
S.C.
K.W
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
Air Handler
N1AHB12
Coil
T.C.
1.03
1.03
1.03
1.00
1.02
2 1.00
1.02
1.00
1.01
1.02
1.02
1.00
1.00
S.C.
1.03
1.03
1.03
1.00
1.02
1.00
1.02
1.00
1.02
1.03
1.02
1.00
1.00
KW
1.00
0.89
0.88
0.94
0.97
0.94
0.97
0.94
0.95
0.93
0.93
0.94
0.94
G2FD036(S,H)17
G2FD030(S,H)17
G2FD036(S,H)17
N1VSB12
N1VSB12
F2RP/F2FP030
F2RP/F2FP036
G1UA036S17,21
G1HD036
G1UA036S14
G2FD035(S,H)14
G2FD036(S,H)17
G2FD036(S,H)21
G1FA036S17,21
G1FA036S14
12
Unitary Products Group
036-21031-004 Rev. A (0603)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
INDOOR COIL MODEL NO.
E4FH036S06
F2RP/F2FP036
1150
ID CFM
1250
1350
CONDENSER
ID DB (°F)
ID WB (°F)
T.C.
85
80
75
70
85
80
67
75
70
85
80
75
70
ENTERING AIR
TEMPERATURE
72
67
62
57
72
62
57
72
67
62
57
40.5
25.6
2.65
38.8
25.0
2.86
37.2
24.3
3.27
35.5
23.8
3.74
33.8
23.2
4.30
32.1
22.6
4.86
37.4
25.7
2.63
35.8
25.0
2.86
34.3
24.6
3.23
32.7
23.9
3.71
31.1
23.3
4.28
29.5
22.7
4.85
34.3
26.0
2.63
32.8
25.4
2.84
31.6
25.0
3.21
30.1
24.2
3.69
28.6
23.6
4.25
27.1
23.0
4.81
31.6
26.3
2.60
30.2
25.6
2.83
28.9
24.9
3.21
27.6
24.3
3.67
26.3
23.9
4.21
25.0
23.5
4.75
40.8
26.5
2.69
39.1
25.9
2.90
37.5
25.5
3.28
35.7
24.9
3.75
34.0
24.3
4.31
32.3
23.7
4.87
37.7
26.8
2.67
36.1
26.0
2.89
34.6
25.6
3.26
33.0
25.0
3.73
31.4
24.3
4.31
29.8
23.6
4.89
34.7
27.1
2.66
33.2
26.5
2.87
31.9
26.0
3.25
30.3
25.2
3.72
28.9
24.5
4.29
27.5
23.8
4.86
31.9
27.2
2.64
30.5
26.6
2.86
29.2
25.9
3.24
27.9
25.3
3.70
26.6
24.5
4.26
25.3
23.7
4.82
41.0
27.5
2.78
39.3
26.9
3.00
37.6
26.3
3.39
35.9
25.9
3.84
34.2
25.3
4.43
32.5
24.7
5.02
37.9
27.6
2.77
36.3
27.0
2.98
34.9
26.7
3.36
33.2
25.9
3.84
31.6
25.3
4.40
30.0
24.7
4.96
35.0
28.2
2.74
33.5
27.4
2.96
32.1
26.9
3.34
30.5
26.1
3.82
29.0
25.5
4.38
27.5
24.9
4.94
32.1
28.2
2.74
30.8
27.6
2.94
29.6
26.9
3.34
28.2
26.1
3.80
27.1
25.6
4.36
26.0
25.1
4.92
75
85
S.C.
K.W
T.C.
S.C.
K.W
T.C.
95
S.C.
K.W
T.C.
105
115
125
S.C.
K.W
T.C.
S.C.
K.W
T.C.
S.C.
K.W
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
T.C.
S.C.
KW
Air Handler
N1AHB12
N1VSB12
F2RP042
Coil
G2FD036(S,H)17
G2FD036(S,H)17
1.00
1.01
1.00
1.02
1.01
1.01
1.01
1.00
1.00
1.02
1.01
1.00
1.01
1.00
1.02
1.01
1.01
1.01
1.00
1.00
1.02
1.01
1.01
0.96
1.01
1.02
1.01
1.01
1.01
1.01
1.01
1.02
1.01
G1UA048S21
G1UA048S17
G2FD42(S,H)21
G2FD046(S,H)17
G2FD036(S,H)21
G2FD036(S,H)17
G1FA048S21
G1FA048S17
Unitary Products Group
13
036-21031-004 Rev. A (0603)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
INDOOR COIL MODEL NO.
E4FH042S06
F2RP/F2FP042
1200
ID CFM
1400
1600
CONDENSER
ID DB (°F)
ID WB (°F)
T.C.
85
80
75
70
85
80
67
75
70
85
80
67
75
70
ENTERING AIR
TEMPERATURE
72
67
62
57
72
62
57
72
62
57
48.1
30.2
3.09
45.9
29.5
3.33
43.1
28.4
3.69
40.3
27.4
4.11
37.6
26.5
4.60
34.9
25.6
5.09
44.3
30.2
3.06
42.3
29.7
3.31
39.7
28.6
3.67
37.1
27.5
4.09
34.6
26.7
4.57
32.1
25.9
5.05
40.6
30.9
3.03
38.7
30.1
3.28
36.3
29.0
3.64
34.0
28.2
4.05
31.7
27.0
4.54
29.4
25.8
5.03
37.1
31.1
3.01
35.4
30.4
3.25
33.3
29.3
3.61
31.1
28.3
4.02
29.0
27.1
4.50
26.9
25.9
4.98
48.4
31.1
3.27
46.2
30.4
3.52
43.4
29.4
3.88
40.6
28.5
4.30
37.9
27.7
4.78
35.2
26.9
5.26
44.6
31.3
3.25
42.6
30.6
3.49
40.0
29.6
3.85
37.4
28.6
4.27
34.9
27.7
4.76
32.4
26.8
5.25
40.9
31.8
3.22
39.0
31.1
3.46
36.7
30.1
3.82
34.3
29.0
4.24
32.0
28.0
4.72
29.7
27.0
5.20
37.5
32.3
3.19
35.7
31.2
3.44
33.6
30.2
3.79
31.5
29.3
4.22
29.4
28.1
4.69
27.3
26.9
5.16
48.7
32.1
3.54
46.5
31.4
3.78
43.6
30.4
4.14
40.8
29.5
4.56
38.0
28.7
5.04
35.2
27.9
5.52
45.0
32.4
3.51
42.9
31.6
3.75
40.2
30.6
4.11
37.7
29.9
4.53
35.1
28.7
5.02
32.5
27.5
5.51
41.2
32.9
3.48
39.3
32.2
3.73
37.0
31.2
4.08
34.5
30.0
4.50
32.2
29.0
4.99
29.9
28.0
5.48
37.8
33.1
3.46
36.0
32.2
3.70
33.9
31.2
4.06
31.8
30.2
4.47
30.3
29.3
4.98
28.8
28.4
5.49
75
85
S.C.
K.W
T.C.
S.C.
K.W
T.C.
95
S.C.
K.W
T.C.
105
115
125
S.C.
K.W
T.C.
S.C.
K.W
T.C.
S.C.
K.W
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
T.C.
S.C.
KW
Air Handler
N1AHC16
N1AHC16
N1VSC16
N1VSC16
F2FP048
Coil
G2FD042(S,H)21
G2FD048(S,H)21
G2FD042(S,H)21
G2FD048(S,H)21
1.00
1.03
1.01
1.04
1.03
1.00
1.01
1.01
1.01
1.03
1.03
1.01
1.01
1.01
1.00
1.02
1.01
1.04
1.02
1.00
1.01
1.01
1.01
1.02
1.02
1.01
1.01
1.01
0.99
0.99
0.94
0.95
0.99
0.99
0.98
0.99
0.99
0.99
0.99
0.98
0.99
0.99
G2FD042(S,H)21
G1UA048S21
G1UA048S17
G1UA046S17
G2FD048(S,H)21
G2FD048(S,H)24
G1FA048S21
G1FA048S17
G1FA046S17
14
Unitary Products Group
036-21031-004 Rev. A (0603)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
INDOOR COIL MODEL NO.
E5FH048S06
F2FP048
ID CFM
1450
1600
1750
CONDENSER
ID DB (°F)
ID WB (°F)
T.C.
85
80
67
75
70
85
80
67
75
70
85
80
75
70
ENTERING AIR
TEMPERATURE
72
62
57
72
62
57
72
67
62
57
54.5
35.6
3.82
52.7
34.8
4.18
50.3
33.5
4.56
47.9
32.4
4.81
45.3
30.8
5.32
42.7
29.2
5.83
50.2
35.8
3.76
48.6
35.0
4.11
46.4
33.9
4.50
44.1
32.5
4.75
41.6
31.0
5.26
39.1
29.5
5.77
46.0
36.3
3.71
44.5
35.5
4.06
42.5
34.3
4.44
40.4
33.0
4.69
38.1
31.4
5.21
35.8
29.8
5.73
42.1
36.5
3.67
40.7
35.6
4.01
38.8
34.4
4.40
37.0
33.3
4.65
34.8
31.6
5.17
32.6
29.9
5.69
55.1
37.1
3.92
53.3
36.3
4.28
50.9
35.1
4.67
48.4
33.7
4.92
45.7
32.1
5.42
43.0
30.5
5.92
50.9
37.3
3.86
49.2
36.5
4.21
47.0
35.3
4.60
44.7
33.9
4.85
42.1
32.2
5.36
39.5
30.5
5.87
46.6
37.8
3.81
45.1
37.0
4.16
43.0
35.7
4.54
40.9
34.3
4.79
38.5
32.6
5.30
36.1
30.9
5.81
42.7
38.1
3.76
41.5
37.4
4.12
39.6
36.3
4.50
37.6
34.8
4.75
35.5
33.1
5.27
33.4
31.4
5.79
55.6
38.5
3.98
53.8
37.6
4.34
51.4
36.4
4.73
48.9
35.1
4.98
46.0
33.2
5.48
43.1
31.3
5.98
51.3
38.7
3.92
49.6
37.8
4.27
47.4
36.6
4.66
45.0
35.2
4.91
42.4
33.3
5.41
39.8
31.4
5.91
47.1
39.3
3.87
45.5
38.4
4.21
43.4
37.1
4.60
41.3
35.9
4.85
38.8
33.8
5.36
36.3
31.7
5.87
43.4
39.9
3.82
42.0
38.9
4.17
40.0
37.6
4.55
38.1
36.1
4.80
35.8
34.2
5.32
33.5
32.3
5.84
75
85
S.C.
K.W
T.C.
S.C.
K.W
T.C.
95
S.C.
K.W
T.C.
105
115
125
S.C.
K.W
T.C.
S.C.
K.W
T.C.
S.C.
K.W
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
T.C.
S.C.
KW
Air Handler
N1AHC16
N1AHD20
N1VSC16
N1VSD20
F2V060
Coil
G2FD048(S,H)21
G2FD060(S,H)24
G2FD048(S,H)21
G2FD060(S,H)24
1.01
1.02
1.02
1.04
1.03
1.01
1.01
1.01
1.00
1.01
1.01
1.02
1.00
1.01
1.01
1.01
1.02
1.02
1.04
1.03
1.01
1.01
1.01
1.00
1.01
1.01
1.02
1.00
1.01
1.01
1.00
1.00
0.93
0.93
0.93
1.04
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
F2FP060
G2FD048(S,H)21
G2FD048(S,H)24
G1UA048S21
G1UA060S21
G1UA060S24
G2FD060(S,H)24
G1FA048S21
G1FA060S21
G1FA060S24
Unitary Products Group
15
036-21031-004 Rev. A (0603)
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
INDOOR COIL MODEL NO.
E4FH060S06
G2FD060(S,H)24
1700
ID CFM
1850
2000
CONDENSER
ID DB (°F)
ID WB (°F)
T.C.
85
80
75
70
85
80
67
75
70
85
80
67
75
70
ENTERING AIR
TEMPERATURE
72
67
62
57
72
62
57
72
62
57
65.8
41.6
4.57
64.3
40.9
4.92
62.4
40.3
5.40
60.1
39.4
5.96
57.6
38.5
6.58
55.1
37.6
7.20
60.8
41.9
4.52
59.4
41.1
4.87
57.5
40.4
5.36
55.4
39.5
5.91
53.1
38.7
6.53
50.8
37.9
7.15
55.8
42.5
4.47
54.5
41.8
4.82
52.8
41.2
5.30
50.7
40.1
5.85
48.6
39.1
6.47
46.5
38.1
7.09
51.2
42.7
4.43
50.1
42.3
4.85
48.5
41.5
5.25
46.6
40.6
5.79
44.6
39.3
6.41
42.6
38.0
7.03
66.2
43.0
4.64
64.9
42.7
4.98
62.8
41.7
5.46
60.5
41.0
6.03
58.0
40.1
6.65
55.5
39.2
7.27
61.2
43.3
4.59
60.0
43.0
4.93
58.0
42.0
5.42
55.9
41.2
5.98
53.5
40.3
6.59
51.1
39.4
7.20
56.3
44.0
4.54
55.1
43.6
4.88
53.3
42.8
5.36
51.4
42.0
5.92
49.3
41.1
6.53
47.2
40.2
7.14
51.9
44.6
4.49
50.7
44.0
4.83
49.0
43.1
5.31
47.1
41.9
5.87
45.1
41.1
6.48
43.1
40.3
7.09
66.6
44.6
4.69
65.3
44.1
5.04
63.2
43.4
5.53
60.8
42.5
6.08
58.3
41.6
6.70
55.8
40.7
7.32
61.7
44.9
4.65
60.4
44.4
4.99
58.4
43.6
5.48
58.3
42.8
6.04
53.8
41.7
6.03
49.3
40.6
6.02
56.8
45.8
4.59
55.7
45.4
4.94
53.8
44.3
5.43
51.8
43.4
5.98
49.7
42.6
6.59
47.6
41.8
7.20
52.4
46.2
4.55
51.2
45.6
4.90
49.4
44.4
5.38
47.8
43.7
5.92
45.6
42.6
6.54
43.4
41.5
7.16
75
85
S.C.
K.W
T.C.
S.C.
K.W
T.C.
95
S.C.
K.W
T.C.
105
115
125
S.C.
K.W
T.C.
S.C.
K.W
T.C.
S.C.
K.W
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
T.C.
S.C.
KW
Air Handler
N1AHD20
N1AHD20
N1VSD20
N1VSD20
F2FP060
Coil
G2FD060(S,H)24
G2FD061H24
G2FD060(S,H)24
G2FD061H24
1.00
1.01
1.04
1.03
0.98
1.02
0.98
0.98
1.01
0.98
0.98
1.00
0.99
1.02
0.99
1.00
1.02
0.98
0.98
0.99
0.98
0.98
1.00
1.01
0.96
0.92
1.01
0.94
1.01
1.01
1.01
1.01
1.01
F2FV060H24
G1UA060S21
G1UA060S24
G2FD061H24
G1FA060S21
G1FA060S24
16
Unitary Products Group
036-21031-004 Rev. A (0603)
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO.
EVAPORATOR COIL MODEL NO.
E4FH018S06
F2RP/F2FP024
ID CFM
650
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
600
700
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
25.0
22.4
19.8
20.8
18.5
16.4
19.0
17.0
15.0
16.0
14.1
11.9
12.0
10.5
9.1
1.83
1.88
1.95
1.72
1.77
1.84
1.63
1.73
1.86
1.56
1.68
1.86
1.53
1.53
1.54
1.50
1.48
1.47
4.10
3.56
3.04
3.55
3.08
2.62
3.38
2.87
2.35
2.97
2.43
1.85
2.30
2.02
1.73
1.96
1.76
1.56
25.3
23.1
21.0
21.4
19.5
17.7
19.5
17.6
15.6
16.6
14.9
12.8
12.4
11.3
10.2
10.3
9.4
1.82
1.88
1.97
1.74
1.79
1.86
1.64
1.74
1.89
1.52
1.67
1.90
1.58
1.58
1.59
1.55
1.53
1.52
4.17
3.68
3.19
3.61
3.20
2.80
3.46
2.94
2.41
3.16
2.58
1.95
2.31
2.10
1.89
2.01
1.84
1.68
25.5
23.8
22.1
22.0
20.5
19.0
19.9
18.2
16.3
17.3
15.7
13.8
12.9
12.1
11.3
10.9
10.1
9.3
1.80
1.88
1.98
1.76
1.81
1.88
1.64
1.76
1.91
1.49
1.66
1.94
1.62
1.63
1.63
1.59
1.58
1.56
4.24
3.79
3.35
3.67
3.32
2.97
3.54
3.01
2.48
3.36
2.73
2.05
2.32
2.18
2.03
2.06
1.92
1.79
60
47
40
30
17
10
9.8
8.7
7.6
8.5
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
T.C.
S.C.
KW
Air Handler
Coil
F2RP/F2FP018
0.87
0.97
1.02
1.02
0.93
0.94
0.95
0.95
0.94
1.04
1.06
1.06
G2FD024(S,H)14,17
G2FD030(S,H)17
G2FD035(S,H)14
Unitary Products Group
17
036-21031-004 Rev. A (0603)
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO.
EVAPORATOR COIL MODEL NO.
E4FH024S06
F2RP/F2FP030
ID CFM
800
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
750
850
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
29.0
28.3
27.6
24.6
23.5
22.5
22.8
21.4
19.9
18.2
17.7
17.2
12.9
12.7
12.5
10.7
10.2
9.6
2.17
2.33
2.54
1.99
2.13
2.31
1.92
2.04
2.20
1.77
1.91
2.09
1.59
1.72
1.89
1.49
1.62
1.79
4.06
3.68
3.29
3.62
3.23
2.85
3.43
3.02
2.62
2.96
2.66
2.36
2.39
2.16
1.93
2.20
1.92
1.64
29.3
28.8
28.3
25.1
24.0
22.9
23.0
21.4
19.8
18.6
17.7
16.8
13.2
12.9
12.6
10.9
10.3
9.7
2.13
2.29
2.50
1.98
2.12
2.30
1.92
2.03
2.17
1.76
1.89
2.07
1.59
1.72
1.89
1.50
1.63
1.79
4.17
3.81
3.44
3.72
3.32
2.92
3.47
3.06
2.64
3.03
2.69
2.34
2.44
2.20
1.96
2.22
1.94
1.65
29.6
29.3
29.0
25.7
24.5
23.3
23.3
21.5
19.7
18.9
17.7
16.5
13.4
13.1
12.8
11.1
10.4
9.8
2.09
2.26
2.46
1.97
2.11
2.28
1.91
2.01
2.14
1.75
1.88
2.04
1.59
1.72
1.88
1.51
1.63
1.80
4.29
3.94
3.58
3.82
3.41
2.99
3.52
3.09
2.65
3.10
2.71
2.32
2.48
2.24
1.99
2.25
1.96
1.66
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
T.C.
S.C.
KW
Air Handler
Coil
F2RP/F2FP024
1.00
1.00
1.00
0.99
1.00
1.02
1.02
0.97
1.00
0.98
0.98
1.02
G2FD035(S,H)14
G2FD030(S,H)17
G2FD024(S,H)14,17
18
Unitary Products Group
036-21031-004 Rev. A (0603)
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
EVAPORATOR COIL MODEL NO
E4FH30S06
G2FD030(S,H)17
ID CFM
1050
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
950
1150
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
33.7
26.4
25.7
23.0
22.0
21.0
21.3
19.9
18.6
17.2
16.7
16.2
12.2
12.0
11.8
10.1
9.6
2.53
2.67
2.85
2.34
2.46
2.61
2.25
2.35
2.48
2.31
2.41
2.55
2.08
2.19
2.31
1.97
2.06
2.17
4.02
3.66
3.29
3.62
3.26
2.89
3.41
3.06
2.69
2.81
2.55
2.27
2.43
2.16
1.90
2.25
1.93
1.63
33.9
33.1
32.3
29.2
28.0
26.8
26.8
25.2
23.6
22.8
21.6
20.1
17.6
16.4
15.2
15.1
13.6
12.2
2.51
2.66
2.84
2.33
2.46
2.62
2.38
2.50
2.65
2.33
2.43
2.56
2.10
2.21
2.34
2.00
2.09
2.19
4.09
3.76
3.43
3.68
3.33
2.98
3.45
3.10
2.73
2.86
2.59
2.28
2.46
2.18
1.92
2.27
1.97
1.68
34.1
33.8
33.5
29.6
28.6
27.6
27.1
25.6
24.0
23.3
22.0
20.4
18.0
16.8
15.6
15.5
13.9
12.5
2.49
2.65
2.83
2.57
2.70
2.87
2.26
2.36
2.49
2.34
2.44
2.58
2.12
2.23
2.36
2.04
2.13
2.23
4.16
3.87
3.56
3.74
3.40
3.06
3.48
3.13
2.77
2.92
2.62
2.29
2.48
2.21
1.95
2.30
1.98
1.69
60
47
40
30
17
10
9.1
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
T.C.
S.C.
KW
Air Handler
F2RP/F2FP030
F2RP/F2FP036
Coil
1.00
1.00
1.00
1.00
1.00
0.99
1.00
1.00
1.00
1.00
1.01
1.01
1.01
1.01
1.01
1.00
1.01
1.01
1.01
1.01
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
G2FD035(S,H)14
G1HD036
G2FD036(S,H)17
G2FD036(S,H)21
G1UA036S14
G1FA036S14
G1UA036S17,21
G1FA036S17,21
Unitary Products Group
19
036-21031-004 Rev. A (0603)
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO.
EVAPORATOR COIL MODEL NO.
E4FH036S06
F2RP/F2FP036
ID CFM
1250
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
1150
1350
K.W.
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
MBTUH
C.O.P.
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
43.3
41.2
39.2
37.31
35.18
33.08
33.9
32.0
29.8
28.9
27.1
24.8
23.7
21.3
19.0
20.4
17.6
15.0
3.53
3.67
3.86
3.26
3.39
3.56
3.13
3.23
3.37
2.95
3.01
3.10
2.65
2.73
2.81
2.52
2.57
2.62
3.69
3.38
3.05
3.36
3.05
2.73
3.15
2.88
2.57
2.83
2.60
2.31
2.62
2.28
1.98
2.44
2.06
1.72
43.4
42.2
40.9
37.5
36.0
34.5
34.3
32.7
30.8
29.6
28.0
25.7
24.1
21.8
19.6
21.1
18.5
16.1
3.52
3.68
3.89
3.26
3.41
3.59
3.43
3.58
3.77
2.98
3.05
3.16
2.69
2.78
2.87
2.58
2.63
2.68
3.71
3.45
3.17
3.38
3.10
2.82
3.17
2.91
2.62
2.87
2.65
2.35
2.63
2.30
2.00
2.46
2.11
1.81
43.5
43.1
42.7
37.7
36.8
35.9
34.7
33.4
31.8
30.3
28.8
26.6
24.6
22.3
20.2
21.7
19.1
16.6
3.51
3.69
3.91
3.79
3.97
4.18
3.17
3.29
3.45
3.01
3.10
3.22
2.74
2.83
2.93
2.64
2.70
2.75
3.73
3.51
3.29
3.39
3.15
2.91
3.19
2.95
2.68
2.91
2.69
2.40
2.63
2.32
2.03
2.48
2.13
1.81
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
T.C.
S.C.
KW
Air Handler
Coil
F2RP/F2FP042
1.00
1.00
1.00
1.00
1.00
0.91
0.91
0.91
1.00
1.10
1.09
1.09
G2FD036(S,H)17,21
G2FD042(S,H)21
G2FD046(S,H)17
20
Unitary Products Group
036-21031-004 Rev. A (0603)
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
EVAPORATOR COIL MODEL NO
E4FH042S06
F2RP/F2FP042
ID CFM
1400
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
1200
1000
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
49.0
50.2
50.1
42.4
42.8
42.4
38.5
38.3
37.4
33.1
32.5
31.5
26.3
25.1
23.8
22.4
20.9
19.4
3.71
3.97
4.33
3.35
3.59
3.91
3.43
3.68
3.99
3.29
3.54
3.84
3.08
3.27
3.52
3.07
3.24
3.46
3.94
3.77
3.45
3.72
3.50
3.18
3.27
3.03
2.73
2.92
2.66
2.38
2.51
2.25
1.99
2.19
1.92
1.68
48.5
50.0
50.2
41.9
42.0
42.3
38.1
38.1
37.4
33.1
32.5
31.4
26.6
25.2
24.3
22.8
21.3
20.0
3.63
3.89
4.24
3.31
3.73
3.85
3.40
3.64
3.95
3.29
3.52
3.80
3.09
3.36
3.52
3.10
3.27
3.49
3.92
3.78
3.49
3.71
3.30
3.22
3.26
3.04
2.76
2.92
2.68
2.40
2.53
2.20
2.02
2.19
1.94
1.71
47.2
49.1
49.7
41.3
42.1
42.1
37.7
37.9
37.3
33.1
32.4
31.3
26.9
25.8
24.7
23.1
21.7
20.5
3.56
3.81
4.14
3.27
3.50
3.80
3.37
3.61
3.90
3.28
3.50
3.75
3.11
3.29
3.53
3.13
3.31
3.52
3.90
3.79
3.53
3.70
3.53
3.25
3.26
3.05
2.79
2.93
2.69
2.42
2.55
2.30
2.05
2.20
1.96
1.74
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
T.C.
S.C.
KW
Air Handler
Coil
F2FP048
1.00
0.99
0.99
1.00
0.92
0.96
0.96
0.92
1.08
1.03
1.03
1.08
G2FD042(S,H)21
G2FD046(S,H)17
G2FD048(S,H)21,24
Unitary Products Group
21
036-21031-004 Rev. A (0603)
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
EVAPORATOR COIL MODEL NO
E5FH048S06
F2FP048
ID CFM
1600
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
1450
1750
K.W.
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
MBTUH
C.O.P.
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
55.7
55.3
54.9
48.1
47.3
46.5
45.4
44.3
43.1
37.3
36.3
35.3
29.5
28.1
26.7
25.1
23.5
21.8
4.53
4.45
4.35
4.71
4.46
4.20
4.11
4.17
4.20
3.79
3.95
4.08
3.51
3.76
4.01
3.36
3.65
3.97
3.67
3.71
3.77
2.99
3.10
3.24
3.22
3.09
2.99
2.86
2.67
2.51
2.47
2.20
1.96
2.24
1.92
1.65
55.9
55.8
55.6
48.0
47.5
47.0
43.8
43.0
42.3
37.7
36.7
35.6
29.9
28.4
26.9
25.7
23.9
22.2
4.49
4.41
4.30
4.20
4.22
4.20
4.04
4.12
4.16
3.82
3.98
4.10
3.55
3.79
4.04
3.41
3.69
4.00
3.72
3.78
3.86
3.35
3.30
3.28
3.15
3.04
2.96
2.86
2.68
2.52
2.48
2.20
1.96
2.26
1.94
1.66
56.2
56.2
56.3
48.0
47.7
47.5
42.2
41.8
41.5
38.2
37.1
36.0
30.3
28.7
27.1
26.3
24.4
22.5
4.45
4.36
4.25
3.79
4.00
4.20
3.98
4.07
4.12
3.86
4.00
4.12
3.59
3.82
4.06
3.46
3.72
4.02
3.77
3.85
3.95
3.71
3.50
3.31
3.09
3.00
2.93
2.87
2.69
2.53
2.48
2.20
1.96
2.28
1.96
1.68
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
T.C.
S.C.
KW
Air Handler
Coil
F2FP060
1.00
1.01
1.02
1.00
0.96
1.02
1.00
1.05
1.00
G2FD048(S,H)21,24
G2FD060(S,H)24
22
Unitary Products Group
036-21031-004 Rev. A (0603)
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
EVAPORATOR COIL MODEL NO
E4FH060S06
G2FD060(S,H)24
ID CFM
1850
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
1700
2000
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
MBTUH
K.W.
C.O.P.
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
60
70
80
69.2
67.4
65.7
61.4
58.8
56.1
58.8
55.1
51.5
50.0
48.6
47.1
40.1
39.4
38.7
36.8
34.9
33.0
4.90
5.27
5.73
4.72
5.06
5.49
4.69
4.99
5.37
4.51
4.88
5.34
4.32
4.70
5.16
4.24
4.60
5.07
4.19
3.80
3.40
3.82
3.41
3.00
3.66
3.23
2.80
3.23
2.90
2.58
2.72
2.46
2.20
2.57
2.24
1.92
69.8
68.7
67.5
62.8
60.0
57.1
59.4
55.3
51.1
51.0
48.7
46.3
40.9
40.0
39.1
37.4
35.3
33.2
4.81
5.18
5.64
4.70
5.03
5.45
4.68
4.95
5.30
4.50
4.84
5.28
4.33
4.69
5.15
4.26
4.61
5.08
4.31
3.93
3.55
3.92
3.50
3.07
3.71
3.27
2.82
3.31
2.93
2.56
2.77
2.50
2.23
2.60
2.27
1.93
70.5
69.9
69.2
64.2
61.2
58.1
60.1
55.4
50.7
52.0
48.7
45.4
41.7
40.6
39.6
38.1
35.8
33.5
4.72
5.10
5.55
4.68
5.00
5.41
4.67
4.91
5.24
4.48
4.80
5.22
4.33
4.68
5.13
4.28
4.63
5.09
4.43
4.07
3.70
4.02
3.59
3.15
3.76
3.30
2.84
3.39
2.96
2.54
2.82
2.54
2.26
2.63
2.29
1.95
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
T.C.
S.C.
KW
Air Handler
F2FP060
Coil
1.00
1.00
1.03
1.03
1.17
1.00
0.97
0.86
1.03
F2FV060
G2FD061H24
Unitary Products Group
23
MATCHING INDOOR COMPONENTS
ADD-ON COILS - FOR FURNACE APPLICATIONS
G1NA
UNCASED
UPFLOW
G1UA
1/2 CASED
UPFLOW
G1HD
HORIZONTAL DUCT
G2FD*
MULTI-POSITION
(UPFLOW, HORIZONTAL
AND DOWNFLOW)
G1FA
FULL CASED
UPFLOW
* Available with factory installed horizontal drain pan.
AIR HANDLERS - FOR NON-FURNACE APPLICATIONS
N1AH OR N1VS
MODULAR BLOWER
(UPFLOW, HORIZONTAL
AND DOWNFLOW)
G2FD
COIL
F2RC / F2FC OR
F2RC / F2FP
FAN COIL UNITS
(UPFLOW, HORIZONTAL)
Subject to change without notice. Printed in U.S.A.
036-21031-004 Rev. A (0603)
Copyright © by York International Corp. 2003. All rights reserved.
Supersedes: 036-21031-003 Rev. A (0403)
Unitary
Product
Group
5005
York
Drive
Norman
OK
73069
|