350154-YTG-C-0808
DESCRIPTION
The CZH Series condensing unit is the outdoor part of a versatile
air conditioning system. It is designed to be custom matched with
one of our complete line of evaporator sections, each designed to
serve a specific function. Matching air handlers are available for
upflow, downflow, and horizontal left or right application to provide a
complete system. Electric heaters are available if required. Add-on
coils are available for use with upflow, downflow, or horizontal fur-
naces. Field installed accessories are available as needed.
WARRANTY
5-year limited parts warranty.
TECHNICAL GUIDE
10-year limited compressor warranty.
Premium System Warranty - Limited lifetime compressor and 10-
year parts when matched with an approved York Affinity furnace or
UPG air handler and coil.
AFFINITY
R-410A SPLIT-SYSTEM AIR CONDITIONERS
18 SEER
FEATURES
•
Superior Coil Protection – A stamped decorative metal coil
guard completely protects coil from debris and other large dam-
aging material while a polymer mesh further protects the coil
against smaller particles.
MODELS: CZH024 THRU 060
(2 THRU 5 NOMINAL TONS)
•
•
Isolated Compressor Compartment – A molded composite
bulkhead isolates the compressor from the rest of the unit reduc-
ing sound and vibration.
Protected Compressors – Each compressor is protected
against abnormal pressures by an internal pressure relief valve
and factory installed high and low pressure controls. Additional
protection against moisture and debris is provided by factory
installed liquid line filter driers.
•
•
Environmentally Friendly Refrigerant – Next generation
refrigerant R-410A delivers environmentally friendly perfor-
mance with zero ozone depletion.
Durable Finish – Automotive quality finish provides the ultimate
protection from harmful U.V. rays and rust creep ensuring long-
lasting high quality appearance. A powder-paint topcoat is
applied over a baked-on primer, using a galvanized, zinc coated
steel base material. The result is a finish that has been proven in
testing to provide 33% greater durability than conventional pow-
der-coat finishes.
•
•
Lower Installed Cost – Designed to provide enhanced install-
ability by featuring a slide-down control compartment and angled
service valves to reduce overall installation time and cost.
Low Operating Sound Levels – A fan design boasting technol-
ogy adapted from aeronautic and defense engineering provides
for whisper quiet operation by allowing airflow to flow smoothly
and efficiently across the fan tips.
ISO 9001
Certified Quality
Management System
•
•
•
Filter-Drier – A factory installed, solid core liquid line filter-drier
filters harmful debris and moisture from the system.
LISTED
Easy Service Access – A full end, full service, access panel
with handle makes for easy entry to internal components.
Composite Base - Strong and durable composite base pan
resists rust and corrosion while it helps reduce vibrations and
noise.
•
Quiet drive system - Features combination of swept-wing fan,
composite base pan, isolated compressor compartment and
two-stage compressor to reduce overall sound to a mere whis-
per.
Due to continuous product improvement, specifications
are subject to change without notice.
•
•
Low RPM fan motor - Helps to reduce airflow noise.
Agency Listed - U.L. and C.U.L. listed - approved for outdoor
application. The unit is certified in accordance with the Unitary
Small Equipment cerification program, which is based on ARI
Standard 210/240.
up-to-date technical information.
Additional rating information can be found at
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
350154-YTG-C-0808
Additional R-410A Charge / TXV Size for Various Matched Systems
Outdoor Unit
CZH02411
1TVM(902/4F1)
16 - 2
CZH03611
1TVM(904/4H1)
15 - 14
CZH04811
1TVM(905/4J1)
13 - 8
CZH06011
1TVM(906/4K1)
14 - 1
Approved System Thermal Expansion Valve1
Factory Charge, lbs-oz
Indoor Coil2
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC37A
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC48C
FC/MC/PC48D
FC/PC60C
FC/MC/PC60D
FC/MC62D
HC36B
TXV Kit3 - Additional Charge, Oz
1
0
–
–
–
–
–
–
–
–
–
–
–
–
0
0
12
–
–
0
–
0
–
–
0
0
0
–
–
7
24
24
24
7
–
7
–
7
–
17
17
–
10
10
–
7
–
–
–
–
–
39
–
15
–
0
HC42C
–
24
–
–
HC60D
–
1
UC48D
17
–
7
10
–
UC60D
–
AV36C
7
0
–
AV/SV48D
–
–
1
AV/SV60D
–
–
0
F4FV060D
–
–
1
FOOTNOTES:
1
2
3
Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.
PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
A TXV kit must be used with these coils to obtain system performance.
Note: If a TXV is factory installed on the coil, it must be replaced with the listed TXV.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of intercon-
necting line tubing.
2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified on the previous page.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evap-
orator + adder for line set.
Johnson Controls Unitary Products
3
350154-YTG-C-0808
COOLING CAPACITY - With Air Handler Coils
AIR HANDLER
COOLING
NET MBH
COIL
MODEL1
UNIT
MODEL
RATED
CFM
MODEL
W
STAGE
SEER
EER
1 PH 18 SEER AC WITH MV
1
620
800
18.2
13.8
17.2
13.8
17.2
14.0
17.5
14.0
17.5
14.3
17.9
18.0
25.2
18.1
25.3
18.0
25.2
18.2
25.4
18.1
25.6
25.1
35.1
25.1
35.1
25.1
35.1
25.2
35.5
27.3
40.5
28.6
42.3
14.50
13.80
14.50
13.80
14.65
14.00
14.65
14.00
15.25
14.45
14.90
13.55
15.00
14.00
15.40
13.95
15.40
14.15
15.40
14.25
14.20
12.45
14.20
12.45
14.00
12.35
14.05
12.50
12.55
11.55
13.20
12.00
MV12B
MV12B
MV12B
MV12B
MV12D
MV12B
MV16C
MV12D
MV16C
MV12D
MV16C
MV16C
MV20D
MV20D
MV20D
MV20D
17
17
17
17
24
17
21
24
21
24
21
21
24
24
24
24
FC/MC/PC35B
2
17.05
17.05
17.20
17.20
18.00
17.70
18.00
18.40
18.40
18.50
17.30
17.30
17.00
17.00
15.30
16.00
23.6
18.2
23.6
18.5
24.0
18.5
24.0
18.9
24.6
25.6
36.0
25.7
36.2
25.6
36.0
25.9
36.4
25.7
36.6
34.0
46.0
34.0
46.0
34.0
46.0
34.1
46.5
40.2
55.5
42.1
58.0
1
620
FC/MC/PC35C
2
800
1
620
CZH02411
FC/MC/PC43B
2
800
1
620
FC/MC/PC43C
2
800
1
645
FC/MC/PC48D
2
835
1
775
FC/MC/PC43B
2
1200
775
1
FC/MC/PC43C
2
1200
735
1
CZH03611
FC/MC/PC48D
2
1135
775
1
FC/MC/PC48C
2
1200
735
1
FC/MC62D
2
1135
1000
1600
1000
1600
1020
1600
1020
1600
1030
1800
1030
1800
1
FC/MC/PC48C
2
1
FC/MC/PC48D
2
CZH04811
CZH06011
1
FC/MC/PC48D
2
1
FC/MC62D
2
1
FC/MC/PC60D
2
1
FC/MC62D
2
1 PH 18 SEER AC WITH AV/SV
1
600
765
18.4
23.8
25.7
35.6
33.1
44.5
33.0
44.5
41.5
55.5
13.9
17.3
18.1
24.9
24.4
34.0
24.4
34.0
28.2
40.5
14.95
14.10
15.25
13.45
13.60
12.10
13.60
12.10
13.00
11.65
CZH02411
CZH03611
AV36C
AV36C
21
21
24
24
24
N / A
N / A
N / A
N / A
N / A
17.60
18.00
16.60
16.50
15.70
2
1
830
2
1270
1135
1610
1085
1655
1145
1765
1
AV/SV48D
AV/SV60D
AV/SV60D
2
CZH04811
CZH06011
1
2
1
2
1 PH 18 SEER AC WITH F*F*
1
1200
1600
1200
1780
33.6
44.5
41.8
55.5
24.8
34.0
28.4
40.5
13.75
12.15
12.80
11.60
CZH04811
CZH06011
F4FV060
F4FV060
24
24
N / A
N / A
16.85
15.55
2
1
2
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1
MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
4
Johnson Controls Unitary Products
350154-YTG-C-0808
COOLING CAPACITY - CZH02411 With Variable Speed Furnaces
COOLING
NET MBH
VARIABLE SPEED
FURNACE MODEL
COIL
W
MODEL1
RATED
CFM
STAGE
SEER
EER
TOTAL
SENSIBLE
1 PH 18 SEER AC WITH VARIABLE SPEED FURNACES2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
470
750
625
800
560
820
470
750
625
800
560
820
560
820
590
805
565
815
565
790
550
775
515
760
550
815
595
805
525
765
590
815
585
805
515
760
550
800
550
775
595
805
515
760
590
815
590
805
565
815
565
790
595
805
17.2
23.2
18.1
23.2
17.9
23.4
17.4
23.6
18.6
23.6
18.1
24.0
17.9
23.4
17.7
23.0
17.8
23.2
17.7
23.0
17.5
23.0
17.4
23.0
17.5
23.2
17.8
23.0
17.5
23.0
17.9
23.2
18.0
23.6
17.5
23.4
17.8
23.6
17.4
22.8
17.5
23.0
17.0
22.6
17.5
23.0
17.7
23.2
17.8
23.2
17.8
23.2
17.0
22.4
13.0
16.9
13.7
16.9
13.6
17.0
13.2
17.2
14.1
17.2
13.7
17.5
13.6
17.0
13.1
16.3
13.1
16.3
13.1
16.3
12.7
16.1
12.4
16.1
12.7
16.5
13.3
16.4
12.6
16.2
13.2
16.6
13.3
16.7
12.6
16.3
12.9
16.7
12.6
15.9
12.6
15.7
11.9
15.5
12.6
15.7
13.2
16.3
13.3
16.3
13.2
16.3
12.8
15.7
14.15
13.55
14.25
13.05
14.55
13.45
14.35
13.75
14.60
13.30
14.70
13.70
14.55
13.55
14.25
13.50
14.50
13.50
14.25
13.50
14.00
13.25
14.00
13.50
14.25
13.25
14.25
13.50
14.25
13.75
14.25
13.50
14.25
13.50
14.25
13.75
14.25
13.75
13.75
13.25
14.00
13.25
13.75
13.25
14.00
13.50
14.25
13.50
14.50
13.75
14.25
13.50
13.75
13.00
PV8*A12
PV9*A12
FC/MC/PC32A
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC37A
FC/MC/PC37A
FC/MC/PC43B
HC36B
14
14
17
14
14
14
17
14
17
17
14
17
17
14
17
17
14
17
17
14
14
17
17
14
17
17
14
16.70
16.60
17.05
17.00
17.00
17.35
17.10
16.75
17.00
16.75
16.50
16.50
16.50
17.00
16.75
16.75
16.75
16.75
17.00
16.25
16.50
16.00
16.50
16.75
17.25
17.00
16.00
P(C,V)9*B12
PV8*A12
PV9*A12
P(C,V)9*B12
P(C,V)9*B12
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
FC/MC/PC30A
FC/MC/PC30B
FC/MC/PC30B
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC35B
FC/MC/PC36A
FC/MC/PC36B
FC/MC/PC36B
FC/MC/PC37A
FC/MC/PC43B
FC/MC/PC43B
HC30
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*A12
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
HD36
HD36
HD36
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
UC30A
UC30B
UC30B
Y*(8,L)C*A12
UC36A
For Notes See Page 6.
Johnson Controls Unitary Products
5
350154-YTG-C-0808
COOLING CAPACITY - CZH02411 With Variable Speed Furnaces (Continued)
COOLING
NET MBH
VARIABLE SPEED
FURNACE MODEL
COIL
W
MODEL1
RATED
CFM
STAGE
SEER
EER
TOTAL
SENSIBLE
1 PH 18 SEER AC WITH VARIABLE SPEED FURNACES2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
525
765
590
815
625
800
625
800
625
800
535
800
625
800
625
800
625
800
625
800
565
790
550
815
590
815
550
800
590
815
565
790
590
818
16.6
22.2
17.0
22.4
17.8
23.0
17.8
23.0
17.9
22.8
17.6
23.4
17.7
22.8
17.6
22.8
18.0
23.2
17.1
22.2
17.7
23.0
17.5
23.2
17.9
23.2
17.8
23.6
17.5
23.0
17.8
23.2
17.0
22.4
11.9
15.5
12.8
15.7
13.4
16.2
13.4
16.3
13.5
16.3
12.7
16.6
13.3
16.0
12.7
15.5
13.4
16.2
12.8
15.6
13.1
16.3
12.7
16.5
13.2
16.6
12.9
16.7
12.6
15.7
13.2
16.3
12.8
15.7
13.50
13.25
13.75
13.00
14.00
13.25
14.00
13.00
14.00
13.00
14.00
13.25
13.75
13.00
13.75
13.00
14.00
13.25
13.25
12.75
14.25
13.50
14.25
13.25
14.25
13.50
14.25
13.75
14.00
13.50
14.25
13.50
13.75
13.00
Y*(8,L)C*B12
Y*9C*B12
G*9V*A12
G*9V*A12
G*9V*A12
G*9V*A12
G*9V*A12
G*9V*A12
G*9V*A12
G*9V*A12
G*9V*B12
G*9V*B12
G*9V*B12
G*9V*B12
G*9V*B12
G*9V*B12
G*9V*B12
UC36B
UC36B
17
17
14
14
14
14
14
14
14
14
17
17
17
17
17
17
17
16.00
16.00
16.50
16.25
16.50
16.25
16.25
16.00
16.50
15.75
16.75
16.50
16.75
17.00
16.50
17.00
16.00
FC/MC/PC30A
FC/MC/PC32A
FC/MC/PC36A
FC/MC/PC37A
HC30
HD36
UC30A
UC36A
FC/MC/PC30B
FC/MC/PC35B
FC/MC/PC36B
FC/MC/PC43B
HD36
UC30B
UC36B
1
MC coils available with a factory installed horizontal drain pan.
2 Variable speed furnaces have B.O.D (Blower on Delay) standard.
6
Johnson Controls Unitary Products
350154-YTG-C-0808
COOLING CAPACITY - CZH03611With Variable Speed Furnaces
COOLING
NET MBH
VARIABLE SPEED
FURNACE MODEL
COIL
W
MODEL1
RATED
CFM
STAGE
SEER
EER
TOTAL
SENSIBLE
1 PH 18 SEER AC WITH VARIABLE SPEED FURNACES2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
750
1185
780
25.4
35.8
25.6
35.6
25.4
36.0
24.6
36.2
25.7
36.0
25.6
35.6
25.7
35.8
25.8
36.0
24.7
36.4
24.7
36.4
25.9
36.2
25.9
36.2
25.9
36.2
25.9
36.2
25.9
36.2
25.9
36.4
25.9
36.4
26.0
36.6
26.0
36.6
26.0
36.8
24.6
36.2
25.7
36.0
25.6
36.0
25.8
36.0
24.6
35.0
25.0
35.4
25.8
35.2
25.0
35.2
17.9
25.0
18.0
24.9
17.9
25.2
17.3
25.3
18.1
25.2
18.0
24.9
18.1
25.0
18.1
25.2
17.4
25.4
17.4
25.4
18.2
25.3
18.2
25.3
18.2
25.3
18.2
25.3
18.2
25.3
18.2
25.4
18.2
25.4
18.3
25.6
18.3
25.6
18.3
25.7
17.3
25.3
18.1
25.2
18.0
25.2
18.1
25.2
16.7
24.3
17.5
24.7
19.2
24.3
17.4
24.5
14.80
13.25
14.75
13.00
14.90
13.70
14.80
13.80
15.10
13.50
14.85
13.25
15.30
13.60
15.05
13.65
15.15
14.00
15.15
14.00
15.45
13.55
15.60
13.80
15.60
13.80
15.25
13.75
15.25
13.75
15.40
13.90
15.40
13.90
15.40
13.70
15.25
13.90
15.30
14.05
14.85
13.85
15.20
13.50
15.25
13.75
15.05
13.65
14.25
12.50
14.25
13.25
14.25
13.25
14.00
12.75
PV8*A12
PV9*A12
FC/MC/PC37A
FC/MC/PC37A
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
UC48D
14
14
17
21
21
17
21
21
21
21
21
21
21
21
21
24
24
21
21
24
21
21
21
21
17
21
21
17
17.50
17.50
17.80
17.70
17.90
17.60
18.00
17.90
18.20
18.20
18.35
18.40
18.40
18.20
18.20
18.30
18.30
18.35
18.20
18.25
17.80
18.05
18.25
17.90
17.00
17.25
17.25
16.75
1200
750
PV8*B16
1200
640
PV8*C16
1200
780
PV8*C20
1200
770
P(C,V)9*B12
P(C,V)9*C16
P(C,V)9*C20
PV8*C16
1185
770
1175
790
1195
640
1200
640
PV8*C16
1200
780
PV8*C20
FC/MC/PC48C
FC/MC/PC48C
UC48D
1200
770
P(C,V)9*C16
P(C,V)9*C16
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
PV8*C20
1175
770
1175
790
FC/MC/PC48C
UC48D
1195
790
1195
775
FC/MC/PC48D
UC48D
1220
775
1220
780
FC/MC62D
1200
790
P(C,V)9*C20
P(C,V)9*D20
PV8*C16
FC/MC62D
1195
775
FC/MC62D
1220
640
HC42C
1200
780
PV8*C20
HC42C
1200
770
P(C,V)9*C16
P(C,V)9*C20
Y*(8,L)C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
HC42C
1175
790
HC42C
1195
745
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC35B
1220
815
1235
960
1170
810
Y*9C*B12
1190
For Notes See Page 10.
Johnson Controls Unitary Products
7
350154-YTG-C-0808
COOLING CAPACITY - CZH03611With Variable Speed Furnaces (Continued)
COOLING
NET MBH
VARIABLE SPEED
FURNACE MODEL
COIL
W
MODEL1
RATED
CFM
STAGE
SEER
EER
TOTAL
SENSIBLE
1 PH 18 SEER AC WITH VARIABLE SPEED FURNACES2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
790
1215
760
25.0
35.4
24.6
35.6
24.8
34.6
24.6
34.8
25.0
34.8
25.0
35.0
25.0
34.8
25.4
34.6
24.6
35.2
24.2
34.2
24.6
34.8
25.0
35.4
24.8
35.0
25.0
34.8
24.6
34.8
24.8
35.4
24.8
35.4
25.2
35.8
24.8
35.8
25.0
35.4
25.2
35.6
24.8
35.8
25.6
36.4
24.8
36.2
25.6
36.2
24.8
36.6
25.0
35.8
24.8
35.8
17.5
24.7
16.8
25.3
17.3
23.7
16.7
24.1
17.4
24.1
17.4
24.1
17.3
23.9
18.2
24.1
16.8
25.1
15.9
22.7
16.9
24.1
17.6
24.7
17.0
24.3
17.5
24.3
16.9
24.3
17.0
25.5
16.9
24.9
17.6
25.1
17.0
25.1
17.5
24.9
17.5
25.1
16.9
25.1
17.9
25.7
16.9
25.1
17.9
25.5
17.1
26.5
17.6
25.1
17.0
25.1
14.25
13.00
14.25
12.75
14.00
12.50
14.25
12.75
14.50
13.00
14.50
13.25
14.25
12.75
14.25
13.00
14.25
12.75
14.00
13.00
14.25
13.00
14.50
13.50
14.50
13.50
14.25
12.50
14.25
13.25
14.25
13.00
14.25
12.75
14.50
13.50
14.50
13.50
14.25
12.75
14.25
13.00
14.25
13.25
14.75
13.75
14.50
13.75
14.75
13.50
14.50
13.25
14.50
13.50
14.50
13.50
Y*9C*C16
Y*9C*C20
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC36A
FC/MC/PC36B
FC/MC/PC36C
FC/MC/PC36C
FC/MC/PC36B
FC/MC/PC36C
FC/MC/PC36C
FC/MC/PC37A
FC/MC/PC42B
FC/MC/PC42C
FC/MC/PC42C
FC/MC/PC42B
FC/MC/PC42C
FC/MC/PC42C
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
HC42
21
21
14
17
21
21
17
21
21
14
17
21
21
17
21
21
17
21
21
17
21
21
21
21
21
21
21
21
17.25
17.00
16.75
17.00
17.50
17.50
17.00
17.25
17.25
16.75
17.25
17.50
17.50
17.00
17.25
17.25
17.25
17.50
17.50
17.00
17.25
17.25
17.75
17.50
17.75
17.50
17.50
17.50
1330
815
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*B12
1190
745
1220
805
1235
800
1240
800
1165
915
Y*9C*C16
1185
760
Y*9C*C20
1320
655
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*B12
980
760
1175
825
1205
735
1170
800
1195
780
Y*9C*C16
1205
770
Y*9C*C20
1325
745
Y*(8,L)C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*B12
1210
800
1205
745
1190
815
1200
815
Y*9C*C16
1240
780
Y*9C*C20
1200
810
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
1210
720
1155
780
1195
745
Y*9C*C20
1330
800
Y*(8,L)C*C16
1205
745
Y*(8,L)C*C20
HC42
1190
For Notes See Page 10.
8
Johnson Controls Unitary Products
350154-YTG-C-0808
COOLING CAPACITY - CZH03611With Variable Speed Furnaces (Continued)
COOLING
NET MBH
VARIABLE SPEED
FURNACE MODEL
COIL
W
MODEL1
RATED
CFM
STAGE
SEER
EER
TOTAL
SENSIBLE
1 PH 18 SEER AC WITH VARIABLE SPEED FURNACES2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
815
1240
780
25.0
35.6
25.0
35.8
24.8
35.8
24.6
35.4
25.4
36.0
24.8
35.8
25.4
36.0
24.8
36.2
24.4
34.0
24.0
34.2
24.6
34.4
24.6
34.4
24.4
34.2
25.0
34.4
24.2
34.8
24.4
34.6
24.8
35.0
24.4
35.0
24.8
34.6
24.4
34.8
24.4
35.4
25.0
35.6
24.4
35.4
25.0
35.6
24.6
35.8
24.6
34.2
25.0
34.8
24.2
34.0
17.6
24.9
17.6
25.1
17.0
25.1
16.5
24.3
17.7
25.3
16.7
24.9
17.6
25.1
16.9
26.1
16.9
23.3
16.3
23.7
17.0
23.5
17.1
23.5
17.0
23.5
17.8
23.7
16.5
24.9
16.8
23.9
17.4
24.5
16.8
24.1
17.3
24.1
16.7
23.9
16.9
25.1
17.7
25.3
16.7
24.7
17.7
25.1
17.1
25.9
16.9
23.7
17.5
23.7
16.6
23.5
14.25
13.00
14.50
13.25
14.50
13.25
14.25
13.00
14.75
13.75
14.50
13.75
14.75
13.50
14.50
13.25
13.75
12.25
14.00
12.50
14.25
13.00
14.25
13.00
14.00
12.75
14.00
13.00
14.00
12.75
14.25
13.00
14.50
13.50
14.25
13.50
14.00
12.50
14.25
13.00
14.25
13.00
14.50
13.50
14.25
13.50
14.50
13.25
14.25
13.00
14.00
12.25
14.00
12.75
13.75
12.25
Y*9C*C16
Y*9C*C20
HC42
HC42
21
21
17
17
21
21
21
21
14
17
21
21
17
21
21
17
21
21
17
21
21
21
21
21
21
14
14
14
17.25
17.50
17.25
17.00
17.75
17.50
17.50
17.25
16.50
16.75
17.25
17.25
16.75
17.00
16.75
17.00
17.25
17.25
16.75
17.00
17.00
17.50
17.25
17.50
17.25
16.75
16.75
16.25
1200
750
Y*(8,L)C*B12
Y*9C*B12
HD48
1210
710
HD48
1150
810
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
HD48
1210
720
HD48
1155
780
HD48
1195
745
Y*9C*C20
HD48
1330
815
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*B12
UC36A
UC36B
UC36C
UC36C
UC36B
UC36C
UC36C
UC42B
UC42C
UC42C
UC42B
UC42C
UC42C
UC48C
UC48C
UC48C
UC48C
FC/MC/PC36A
FC/MC/PC37A
UC36A
1190
745
1220
805
1235
800
1240
800
1165
915
Y*9C*C16
1185
760
Y*9C*C20
1300
760
Y*(8,L)C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*B12
1175
825
1205
735
1170
800
1195
780
Y*9C*C16
1205
770
Y*9C*C20
1325
810
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
1210
720
1155
780
1195
755
Y*9C*C20
1330
780
G*9V*A12
1200
800
G*9V*A12
1100
780
G*9V*A12
1200
For Notes See Page 10.
Johnson Controls Unitary Products
9
350154-YTG-C-0808
COOLING CAPACITY - CZH03611With Variable Speed Furnaces (Continued)
COOLING
NET MBH
VARIABLE SPEED
FURNACE MODEL
COIL
W
MODEL1
RATED
CFM
STAGE
SEER
EER
TOTAL
SENSIBLE
1 PH 18 SEER AC WITH VARIABLE SPEED FURNACES2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
810
1190
790
25.0
35.2
25.0
35.4
24.6
35.6
25.0
34.8
25.4
34.6
24.6
35.2
25.0
34.8
24.6
34.8
24.8
35.4
25.0
35.4
25.2
35.6
24.8
35.8
25.6
36.2
24.8
36.6
25.0
35.6
25.0
35.8
24.6
35.4
25.4
36.0
24.8
36.2
24.4
34.2
25.0
34.4
24.2
34.8
24.8
34.6
24.4
34.8
24.4
35.4
25.0
35.6
24.6
35.8
17.4
24.5
17.5
24.7
16.8
25.3
17.3
23.9
18.2
24.1
16.8
25.1
17.5
24.3
16.9
24.3
17.0
25.5
17.5
24.9
17.5
25.1
16.9
25.1
17.9
25.5
17.1
26.5
17.6
24.9
17.6
25.1
16.5
24.3
17.6
25.1
16.9
26.1
17.0
23.5
17.8
23.7
16.5
24.9
17.3
24.1
16.7
23.9
16.9
25.1
17.7
25.1
17.1
25.9
14.00
12.75
14.25
13.00
14.25
12.75
14.25
12.75
14.25
13.00
14.25
12.75
14.25
12.50
14.25
13.25
14.25
13.00
14.25
12.75
14.25
13.00
14.25
13.25
14.75
13.50
14.50
13.25
14.25
13.00
14.50
13.25
14.25
13.00
14.75
13.50
14.50
13.25
14.00
12.75
14.00
13.00
14.00
12.75
14.00
12.50
14.25
13.00
14.25
13.00
14.50
13.25
14.25
13.00
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*C16
G*9V*C20
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*C16
G*9V*C20
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC36B
FC/MC/PC36C
FC/MC/PC36C
FC/MC/PC42B
FC/MC/PC42C
FC/MC/PC42C
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
FC/MC/PC48C
HC42
17
21
21
17
21
21
17
21
21
17
21
21
21
21
21
21
17
21
21
17
21
21
17
21
21
21
21
16.75
17.25
17.00
17.00
17.25
17.25
17.00
17.25
17.25
17.00
17.25
17.25
17.75
17.50
17.25
17.50
17.00
17.50
17.25
16.75
17.00
16.75
16.75
17.00
17.00
17.50
17.25
1215
760
1330
800
1165
915
1185
760
1320
800
1195
780
1205
770
1325
815
1200
815
1240
780
1200
780
1195
745
1330
815
1240
780
HC42
1200
710
HD48
1150
780
HD48
1195
745
HD48
1330
800
UC36B
1165
915
UC36C
1185
760
UC36C
1300
800
UC42B
1195
780
UC42C
1205
770
UC42C
1325
780
UC48C
1195
755
UC48C
1330
1
MC coils available with a factory installed horizontal drain pan.
2 Variable speed furnaces have B.O.D (Blower on Delay) standard.
10
Johnson Controls Unitary Products
350154-YTG-C-0808
COOLING CAPACITY - CZH04811With Variable Speed Furnaces
COOLING
NET MBH
VARIABLE SPEED
FURNACE MODEL
COIL
W
MODEL1
RATED
CFM
STAGE
SEER
EER
TOTAL
SENSIBLE
1 PH 18 SEER AC WITH VARIABLE SPEED FURNACES2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
880
33.0
45.0
33.0
45.0
34.1
45.5
34.1
45.5
34.6
45.5
34.6
45.5
33.9
45.5
33.9
45.5
33.8
45.5
33.8
45.5
34.2
46.0
34.1
46.0
33.9
46.0
32.3
44.0
33.4
45.5
33.4
45.5
33.4
45.5
33.4
45.5
33.0
45.0
32.6
44.5
32.6
45.0
32.4
44.5
32.6
44.5
32.4
44.5
33.0
45.0
32.0
44.0
32.8
45.5
24.4
34.4
24.4
34.4
25.2
34.8
25.2
34.8
25.6
34.8
25.6
34.8
25.0
34.8
25.0
34.8
25.0
34.8
25.0
34.8
25.3
35.1
25.2
35.1
25.0
35.1
23.9
33.6
24.6
34.6
24.4
34.4
24.6
34.1
24.6
34.1
24.2
34.0
23.8
33.8
23.8
34.0
23.8
33.6
23.8
33.6
23.8
33.8
24.4
34.0
23.6
33.6
24.0
33.9
13.90
11.95
13.90
11.95
14.15
12.05
14.15
12.05
14.50
11.85
14.50
11.85
13.95
12.05
13.95
12.05
13.95
12.20
13.95
12.20
14.25
12.20
14.00
12.15
14.00
12.30
13.25
11.85
13.50
11.75
13.50
11.75
13.50
11.75
13.50
11.75
13.25
11.50
13.25
11.75
13.50
12.00
13.25
11.50
13.25
11.50
13.25
11.75
13.50
11.75
13.00
11.50
13.50
11.75
PV8*C16
PV8*C16
FC/MC/PC48C
UC48D
21
21
21
21
21
21
21
21
24
24
21
21
24
24
21
21
21
21
24
21
21
21
21
24
24
24
21
16.90
16.90
17.10
17.10
17.50
17.50
16.90
16.90
16.95
16.95
17.20
16.80
17.00
16.25
16.50
16.25
16.25
16.50
16.25
16.25
16.25
16.00
16.00
16.00
16.25
15.75
16.25
1500
880
1500
1030
1610
1030
1610
1090
1600
1090
1600
1010
1580
1010
1580
985
PV8*C20
FC/MC/PC48C
UC48D
PV8*C20
P(C,V)9*C16
P(C,V)9*C16
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
PV8*C20
FC/MC/PC48C
UC48D
FC/MC/PC48C
UC48D
FC/MC/PC48D
UC48D
1560
985
1560
1030
1610
1010
1580
985
FC/MC62D
FC/MC62D
FC/MC62D
HC60D
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
1560
985
1560
1035
1615
1080
1640
1050
1590
1055
1655
1060
1645
1035
1625
1015
1605
1050
1590
1055
1655
1070
1615
1085
1630
1070
1615
1035
1615
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48D
FC/PC60C
FC/PC60C
FC/PC60C
FC/PC60C
FC/MC/PC60D
FC/MC62D
HC60
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*9C*D20
Y*9C*D20
Y*9C*D20
Y*(8,L)C*C16
HD48
For Notes See Page 13.
Johnson Controls Unitary Products
11
350154-YTG-C-0808
COOLING CAPACITY - CZH04811With Variable Speed Furnaces (Continued)
COOLING
NET MBH
VARIABLE SPEED
FURNACE MODEL
COIL
W
MODEL1
RATED
CFM
STAGE
SEER
EER
TOTAL
SENSIBLE
1 PH 18 SEER AC WITH VARIABLE SPEED FURNACES2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1080
1640
1050
1590
1055
1655
1060
1645
1035
1625
1015
1605
1050
1590
1055
1655
1070
1615
1035
1615
1080
1640
1050
1590
1055
1630
1060
1570
1035
1570
1015
1590
1050
1570
1055
1570
1070
1570
1050
1590
1055
1655
1060
1645
1050
1590
1055
1655
1070
1615
1085
1630
1070
1615
1050
1590
32.8
45.5
33.0
45.0
33.0
45.0
32.8
45.5
33.6
45.5
33.6
45.5
33.4
45.5
33.6
45.5
33.6
45.5
31.8
44.0
31.8
44.0
31.8
43.5
31.8
43.5
29.8
42.0
30.0
42.0
30.0
42.5
30.0
42.0
30.0
42.0
30.0
42.0
33.4
45.5
33.4
45.5
33.0
45.0
32.4
44.5
32.6
44.5
32.4
44.5
33.0
45.0
32.0
44.0
33.0
45.0
24.0
33.7
24.0
33.5
24.0
33.5
24.0
33.7
24.6
34.6
24.6
34.8
24.6
34.6
24.6
34.6
24.6
34.6
23.4
33.4
23.4
33.4
23.8
33.0
23.8
33.0
22.0
31.1
21.4
31.1
21.4
31.3
21.2
31.1
21.4
31.1
21.2
31.1
24.6
34.1
24.6
34.1
24.2
34.0
23.8
33.6
23.8
33.6
23.8
33.8
24.4
34.0
23.6
33.6
24.0
33.5
13.25
11.75
13.25
11.75
13.50
11.75
13.25
11.75
13.75
12.00
14.00
12.00
13.50
11.75
13.75
11.75
13.50
11.75
13.00
11.50
12.75
11.50
12.75
11.25
12.75
11.25
12.00
11.00
12.25
11.25
12.25
11.50
12.00
11.00
12.00
11.00
12.00
11.00
13.50
11.75
13.50
11.75
13.25
11.50
13.25
11.50
13.25
11.50
13.25
11.75
13.50
11.75
13.00
11.50
13.25
11.75
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*9C*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*D20
G*9V*D20
HD48
HD48
21
21
21
24
21
21
21
21
24
21
21
21
21
24
21
21
21
21
24
21
21
24
21
21
24
24
24
21
16.00
16.25
16.25
16.25
16.75
16.75
16.25
16.50
16.50
15.75
15.50
15.50
15.75
14.75
15.00
15.00
14.75
14.75
14.75
16.25
16.50
16.25
16.00
16.00
16.00
16.25
15.75
16.25
HD48
HD48
HD60
HD60
HD60
HD60
HD60
UC48C
UC48C
UC48C
UC48C
UC48D
UC60C
UC60C
UC60C
UC60C
UC60D
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48D
FC/PC60C
FC/PC60C
FC/MC/PC60D
FC/MC62D
HC60
G*9V*C16
HD48
For Notes See Page 13.
12
Johnson Controls Unitary Products
350154-YTG-C-0808
COOLING CAPACITY - CZH04811With Variable Speed Furnaces (Continued)
COOLING
NET MBH
VARIABLE SPEED
FURNACE MODEL
COIL
W
MODEL1
RATED
CFM
STAGE
SEER
EER
TOTAL
SENSIBLE
1 PH 18 SEER AC WITH VARIABLE SPEED FURNACES2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1055
1655
1060
1645
1050
1590
1055
1655
1070
1615
1050
1590
1055
1630
1060
1570
1050
1570
1055
1570
1070
1570
33.0
45.0
32.8
45.5
33.4
45.5
33.6
45.5
33.6
45.5
31.8
43.5
31.8
43.5
29.8
42.0
30.0
42.0
30.0
42.0
30.0
42.0
24.0
33.5
24.0
33.7
24.6
34.6
24.6
34.6
24.6
34.6
23.8
33.0
23.8
33.0
22.0
31.1
21.2
31.1
21.4
31.1
21.2
31.1
13.50
11.75
13.25
11.75
13.50
11.75
13.75
11.75
13.50
11.75
12.75
11.25
12.75
11.25
12.00
11.00
12.00
11.00
12.00
11.00
12.00
11.00
G*9V*C20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
HD48
HD48
21
24
21
21
24
21
21
24
21
21
24
16.25
16.25
16.25
16.50
16.50
15.50
15.75
14.75
14.75
14.75
14.75
HD60
HD60
HD60
UC48C
UC48C
UC48D
UC60C
UC60C
UC60D
1
MC coils available with a factory installed horizontal drain pan.
2 Variable speed furnaces have B.O.D (Blower on Delay) standard.
COOLING CAPACITY - CZH06011 With Variable Speed Furnaces
COOLING
NET MBH
VARIABLE SPEED
FURNACE MODEL
COIL
W
MODEL1
RATED
CFM
STAGE
SEER
EER
TOTAL
SENSIBLE
1 PH 18 SEER AC WITH VARIABLE SPEED FURNACES2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1120
1730
1120
1730
1075
1650
1075
1650
1020
1620
1020
1620
1120
1730
1075
1650
1020
1620
1020
1620
1015
1605
1055
1655
41.0
55.0
41.0
55.0
40.4
54.0
40.4
54.0
40.2
54.0
40.2
54.0
42.8
57.0
42.4
56.5
42.0
56.5
40.1
54.5
40.0
55.0
40.0
54.5
27.8
40.1
27.8
40.1
27.4
39.4
27.4
39.4
27.3
39.4
27.3
39.4
29.1
41.6
28.8
41.2
28.5
41.2
27.2
39.7
26.0
36.1
25.8
35.9
12.75
11.40
12.75
11.40
12.55
11.25
12.55
11.25
12.55
11.45
12.55
11.45
13.35
11.70
13.25
11.65
13.20
11.80
12.55
11.50
12.50
11.25
12.25
11.00
PV8*C20
PV8*C20
FC/PC60C
UC60D
21
21
21
21
24
24
21
21
24
24
21
21
15.45
15.45
15.25
15.25
15.25
15.25
16.10
15.95
15.90
15.30
15.25
15.00
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
PV8*C20
FC/PC60C
UC60D
FC/MC/PC60D
UC60D
FC/MC62D
FC/MC62D
FC/MC62D
HC60D
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
Y*(8,L)C*C20
FC/PC60C
FC/PC60C
Y*9C*C20
For Notes See Page 14.
Johnson Controls Unitary Products
13
350154-YTG-C-0808
COOLING CAPACITY - CZH06011 With Variable Speed Furnaces (Continued)
COOLING
NET MBH
VARIABLE SPEED
FURNACE MODEL
COIL
W
MODEL1
RATED
CFM
STAGE
SEER
EER
TOTAL
SENSIBLE
1 PH 18 SEER AC WITH VARIABLE SPEED FURNACES2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1085
1630
1070
1615
1015
1605
1055
1655
1070
1615
1015
1605
1055
1655
1070
1615
1055
1655
1085
1630
1070
1615
1055
1655
1070
1615
1055
1655
1070
1615
40.5
55.0
39.0
53.5
40.5
55.5
40.5
55.5
40.5
54.5
38.5
53.5
38.5
53.0
38.5
53.5
40.0
54.5
40.5
55.0
39.0
53.5
40.5
55.5
40.5
54.5
38.5
53.0
38.5
53.5
26.3
36.3
25.4
34.9
25.8
36.1
26.3
36.3
26.5
35.5
24.6
34.6
24.6
34.4
25.0
34.6
25.8
35.9
26.3
36.3
25.4
34.9
26.3
36.3
26.5
35.5
24.6
34.4
25.0
34.6
12.50
11.25
12.00
10.75
12.50
11.50
12.50
11.00
12.50
11.00
12.00
11.00
11.75
10.75
11.75
10.75
12.25
11.00
12.50
11.25
12.00
10.75
12.50
11.00
12.50
11.00
11.75
10.75
11.75
10.75
Y*9C*D20
Y*9C*D20
Y*(8,L)C*C20
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C20
Y*9C*C20
Y*9C*D20
G*9V*C20
G*9V*D20
G*9V*D20
G*9V*C20
G*9V*D20
G*9V*C20
G*9V*D20
FC/MC62D
HC60
24
24
21
21
24
21
21
24
21
24
24
21
24
21
24
15.00
14.50
15.25
15.25
15.25
14.50
14.25
14.50
15.00
15.00
14.50
15.25
15.25
14.25
14.50
HD60
HD60
HD60
UC60C
UC60C
UC60D
FC/PC60C
FC/MC62D
HC60
HD60
HD60
UC60C
UC60D
1
MC coils available with a factory installed horizontal drain pan.
2 Variable speed furnaces have B.O.D (Blower on Delay) standard.
ACCESSORIES*
SOUND POWER RATINGS*
Hard Start Kit (024-31994-000, 024-31995-000) - Provides
UNIT MODEL
(dBA)
increased starting torque for areas with low voltage.
024
036
048
060
71
73
72
74
TXV Kits - 1TVM9 series thermal expansion valves precisely
meter refrigerant for optimum performance
Dehumidistat (2HU16700124) - Provides increased dehumidi-
fication when matched with variable speed furnace or air han-
dler.
* Rated in accordance with ARI 270-95 Standards.
Room Thermostats - A wide selection of compatible thermo-
stats are available to provide optimum performance and fea-
tures for any installation.
COLOR GRILLES
CHOICE OF SEVERAL COLOR COIL GRILLES TO
COMPLIMENT ANY HOME.
Color Grill
1CP1136
1CP0236
1CP0336
1CP0436
1CP0536
1CP0636
Color Description
Terra Cotta
1 Heat Stage only, manual, mechanical thermostat. Add sub-
base for 3H/2C.
All
All
All
All
All
All
Jet Black
Stone
3H/2C, manual changeover electronic non-programmable ther-
mostat.
Bermuda
Gunmetal
Chocolate
3H/2C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.
3H/2C, auto/manual changeover, electronic programmable.
* For the most current accessory information, refer to the price
book or consult factory.
14
Johnson Controls Unitary Products
350154-YTG-C-0808
COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
CZH02411
FC48D + MV12D
ID CFM
ID DB (°F)
ID WB (°F)
T.C.
550
600
75
650
CONDENSER
ENTERING AIR
TEMPERATURE
80
57
80
62
75
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
75
62
80
67
80
72
62
18.6 19.9 18.9 21.7 23.9 19.0 19.9 19.1 21.8 24.4 19.4 20.0 19.3 22.0 24.9
18.6 17.5 14.9 14.8 11.7 19.2 18.5 15.6 15.5 12.1 19.7 19.4 16.2 16.2 12.5
0.76 0.75 0.76 0.74 0.74 0.75 0.75 0.75 0.73 0.74 0.75 0.75 0.75 0.73 0.74
17.8 18.8 18.0 20.6 22.8 18.3 18.9 18.3 20.9 23.2 18.7 19.1 18.5 21.1 23.6
17.9 17.1 14.5 14.4 11.3 18.4 17.9 15.1 15.1 11.8 18.9 18.6 15.8 15.9 12.2
0.93 0.92 0.93 0.91 0.90 0.92 0.92 0.92 0.90 0.90 0.91 0.91 0.92 0.90 0.90
17.1 17.6 17.1 19.5 21.6 17.5 17.9 17.4 19.9 22.0 17.9 18.2 17.7 20.2 22.3
17.2 16.8 14.0 14.0 10.9 17.7 17.3 14.7 14.8 11.4 18.1 17.9 15.4 15.5 11.9
1.09 1.09 1.09 1.08 1.06 1.08 1.08 1.09 1.07 1.06 1.07 1.08 1.08 1.06 1.05
16.4 16.5 16.2 18.5 20.5 16.8 16.9 16.6 18.9 20.8 17.1 17.2 16.9 19.4 21.0
16.5 16.4 13.6 13.7 10.5 17.0 16.8 14.3 14.4 11.1 17.4 17.2 15.0 15.1 11.7
1.26 1.26 1.26 1.24 1.22 1.24 1.25 1.25 1.24 1.22 1.24 1.24 1.25 1.23 1.21
15.3 15.4 14.9 17.0 19.0 15.7 15.8 15.2 17.3 19.1 16.0 16.2 15.5 17.7 19.3
15.4 15.2 13.0 13.2 10.1 15.8 15.6 13.6 13.9 10.5 16.2 16.0 14.3 14.5 11.0
1.48 1.49 1.49 1.47 1.45 1.47 1.48 1.48 1.47 1.45 1.46 1.47 1.48 1.46 1.45
14.2 14.3 13.6 15.5 17.5 14.6 14.7 13.9 15.8 17.6 15.0 15.1 14.1 16.1 17.7
14.4 14.1 12.4 12.8 9.6 14.7 14.5 13.0 13.4 10.0 15.1 14.9 13.5 13.9 10.4
1.70 1.71 1.71 1.70 1.68 1.69 1.70 1.70 1.69 1.67 1.68 1.69 1.70 1.68 1.67
13.1 13.2 12.3 14.0 15.9 13.5 13.6 12.5 14.3 16.0 13.9 14.0 12.7 14.5 16.1
13.3 13.0 11.8 12.3 9.2 13.6 13.4 12.3 12.9 9.5 14.0 13.8 12.8 13.4 9.7
1.92 1.93 1.93 1.92 1.91 1.91 1.92 1.93 1.91 1.90 1.91 1.91 1.92 1.91 1.90
65
75
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
115
125
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
S.C.
K.W.
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
LOW CFM
Variable Speed
T.C.
S.C.
KW
T.C.
S.C.
KW
Air Handler
AV36C
Coil
–
Coil
Furnace
0.97
0.96
0.96
0.98
0.98
1.00
0.97
0.97
0.97
0.98
0.98
1.00
0.99
1.01
1.01
1.02
1.02
1.00
Y*9C*B12
Y*(8,L)C*A12
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
G*9V*A12
G*9V*B12
G*9V*A12
G*9V*B12
G*9V*A12
G*9V*B12
G*9V*A12
G*9V*B12
G*9V*A12
G*9V*A12
G*9V*B12
G*9V*A12
G*9V*B12
G*9V*A12
G*9V*B12
FC/MC/PC43B
HC30
0.96
0.93
0.94
0.91
0.94
0.95
0.96
0.95
0.91
0.89
0.91
0.96
0.95
0.96
0.94
0.96
0.96
0.94
0.96
0.95
0.95
0.94
0.97
0.95
0.92
0.91
0.90
0.88
0.88
0.83
0.88
0.92
0.92
0.92
0.89
0.83
0.89
0.93
0.91
0.94
0.89
0.94
0.92
0.88
0.90
0.92
0.88
0.88
0.94
0.92
0.89
0.89
1.00
1.01
1.01
1.00
1.01
1.01
1.00
1.01
1.01
1.00
1.01
1.03
1.01
1.03
1.00
1.03
1.01
1.02
1.00
1.03
1.03
1.01
1.03
1.01
1.03
1.01
MV12B
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC48D
MV12B
HD36
MV12B
HD36
MV12B
HD36
MV12D
UC30A
UC30B
Variable Speed
Furnace
PV8*A12
T.C.
S.C.
KW
Coil
UC30B
FC/MC/PC32A
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC37A
FC/MC/PC37A
FC/MC/PC43B
HC36B
0.91
0.96
0.95
0.92
0.98
0.96
0.95
0.95
0.96
0.95
0.94
0.93
0.94
0.96
0.94
0.96
0.97
0.94
0.91
0.96
0.95
0.92
0.99
0.96
0.95
0.91
0.92
0.91
0.89
0.86
0.89
0.92
0.88
0.92
0.93
0.88
0.98
1.02
0.99
0.98
1.03
0.99
0.99
1.01
1.00
1.01
1.01
1.00
1.00
1.00
0.99
1.01
1.02
0.99
UC36A
PV9*A12
UC36B
P(C,V)9*B12
PV8*A12
UC36B
FC/MC/PC30A
FC/MC/PC30B
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC36A
FC/MC/PC36B
FC/MC/PC37A
FC/MC/PC43B
HC30
PV9*A12
P(C,V)9*B12
P(C,V)9*B12
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
FC/MC/PC30A
FC/MC/PC30B
FC/MC/PC30B
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC35B
FC/MC/PC36A
FC/MC/PC36B
FC/MC/PC36B
FC/MC/PC37A
FC/MC/PC43B
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
HD36
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
HD36
UC30A
UC30B
Y*(8,L)C*A12
Y*(8,L)C*B12
UC36A
UC36B
Johnson Controls Unitary Products
15
350154-YTG-C-0808
COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
CZH02411
FC48D + MV12D
ID CFM
ID DB (°F)
ID WB (°F)
T.C.
700
800
75
900
75
CONDENSER
ENTERING AIR
TEMPERATURE
80
57
80
62
75
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
80
67
80
72
62
62
23.1 25.7 25.0 28.6 30.7 24.3 26.0 26.1 28.8 31.1 25.5 26.3 27.1 28.9 31.6
22.6 21.4 17.9 18.3 14.5 23.8 23.1 19.5 19.1 15.3 25.0 24.8 21.0 20.0 16.1
1.12 1.14 1.14 1.16 1.17 1.13 1.14 1.14 1.16 1.18 1.15 1.15 1.15 1.17 1.19
22.5 24.3 23.9 27.1 29.2 23.5 24.7 24.7 27.4 29.7 24.5 25.1 25.5 27.6 30.1
21.9 20.9 17.5 17.8 14.0 23.0 22.4 18.9 18.7 14.8 24.0 23.8 20.3 19.7 15.5
1.31 1.32 1.32 1.34 1.35 1.31 1.32 1.32 1.34 1.36 1.33 1.33 1.33 1.35 1.37
21.8 22.9 22.8 25.6 27.7 22.6 23.4 23.4 26.0 28.2 23.4 23.8 23.9 26.4 28.7
21.3 20.4 17.2 17.3 13.6 22.1 21.6 18.4 18.4 14.3 22.9 22.7 19.6 19.4 15.0
1.49 1.50 1.50 1.52 1.53 1.49 1.50 1.50 1.52 1.54 1.51 1.51 1.51 1.54 1.55
21.2 21.5 21.8 24.0 26.2 21.8 22.1 22.1 24.6 26.7 22.4 22.5 22.3 25.2 27.2
20.6 20.0 16.8 16.8 13.1 21.3 20.9 17.9 18.0 13.7 21.9 21.7 18.9 19.1 14.4
1.67 1.68 1.67 1.70 1.72 1.67 1.68 1.68 1.70 1.72 1.69 1.69 1.69 1.72 1.73
20.1 20.3 20.4 22.6 24.5 20.6 20.9 20.7 23.0 25.0 21.2 21.4 20.9 23.5 25.5
19.5 19.0 16.2 16.3 12.6 20.1 19.8 17.2 17.3 13.2 20.7 20.5 18.2 18.4 13.8
1.93 1.93 1.93 1.95 1.97 1.93 1.94 1.93 1.96 1.98 1.95 1.95 1.94 1.97 1.99
19.0 19.2 19.1 21.2 22.9 19.5 19.7 19.3 21.5 23.4 20.0 20.2 19.5 21.8 23.9
18.5 18.1 15.5 15.8 12.0 19.0 18.8 16.6 16.7 12.6 19.6 19.4 17.6 17.6 13.2
2.17 2.18 2.17 2.20 2.23 2.18 2.18 2.18 2.21 2.23 2.20 2.20 2.19 2.22 2.24
17.9 18.0 17.7 19.8 21.3 18.4 18.5 17.9 20.0 21.8 18.9 19.1 18.1 20.2 22.2
17.4 17.2 14.9 15.3 11.5 17.9 17.8 15.9 16.1 12.1 18.4 18.3 16.9 16.9 12.6
2.42 2.42 2.42 2.45 2.48 2.43 2.43 2.42 2.45 2.48 2.45 2.45 2.44 2.47 2.50
65
75
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
115
125
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
S.C.
K.W.
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HIGH CFM
Variable Speed
Air Handler
AV36C
Coil
–
T.C.
0.97
S.C.
0.97
0.96
0.96
0.98
0.98
1.00
1.00
KW
0.99
Coil
T.C.
S.C.
KW
Furnace
Y*(8,L)C*B12
Y*9C*B12
FC/MC/PC43B
FC/MC/PC43B
HC30
0.97
0.93
0.95
0.90
0.89
0.88
0.89
0.92
0.93
0.92
0.89
0.88
0.89
0.92
0.92
0.92
0.94
0.92
0.94
0.94
0.95
0.91
0.88
0.89
0.92
0.92
0.88
0.89
1.00
MV12B
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC48D
UC48D
0.96
0.96
0.98
0.98
1.00
1.00
1.00
1.00
1.01
1.01
1.00
1.00
0.97
0.94
0.95
0.94
0.95
0.96
0.96
0.96
0.92
0.92
0.92
0.95
0.95
0.95
0.96
0.95
0.96
0.97
0.97
0.95
0.94
0.95
0.96
0.96
0.92
0.92
1.01
1.02
1.01
1.00
1.00
1.01
1.00
1.01
1.00
0.99
1.00
1.02
1.01
1.04
1.02
1.02
1.01
1.03
1.01
1.02
1.02
1.00
1.02
1.01
1.02
1.00
MV12B
Y*(8,L)C*A12
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
MV12B
HD36
MV12B
HD36
MV12D
MV12D
HD36
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
UC30A
UC30B
Variable Speed
Furnace
PV8*A12
Coil
T.C.
S.C.
KW
UC30B
FC/MC/PC32A
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC37A
FC/MC/PC37A
FC/MC/PC43B
HC36B
0.94
0.94
0.95
0.95
0.96
0.96
0.98
0.95
0.95
0.96
0.95
0.95
0.95
0.96
0.95
0.95
0.96
0.97
0.94
0.94
0.95
0.95
0.96
0.96
0.98
0.95
0.92
0.92
0.92
0.92
0.91
0.94
0.93
0.92
0.94
0.95
1.01
1.04
1.02
1.02
1.01
1.04
1.03
1.01
1.01
1.00
1.01
1.02
1.00
1.02
1.01
0.99
1.01
1.02
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
UC36A
PV9*A12
UC36B
P(C,V)9*B12
P(C,V)9*B12
PV8*A12
UC36B
G*9V*A12
G*9V*B12
G*9V*A12
G*9V*B12
G*9V*A12
G*9V*B12
G*9V*A12
G*9V*B12
G*9V*A12
G*9V*A12
G*9V*B12
G*9V*A12
G*9V*B12
G*9V*A12
G*9V*B12
FC/MC/PC30A
FC/MC/PC30B
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC36A
FC/MC/PC36B
FC/MC/PC37A
FC/MC/PC43B
HC30
PV9*A12
P(C,V)9*B12
P(C,V)9*B12
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
FC/MC/PC30A
FC/MC/PC30B
FC/MC/PC30B
FC/MC/PC32A
FC/MC/PC35B
FC/MC/PC35B
FC/MC/PC36A
FC/MC/PC36B
FC/MC/PC36B
FC/MC/PC37A
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
HD36
HD36
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
UC30A
UC30B
UC36A
Y*(8,L)C*A12
UC36B
16
Johnson Controls Unitary Products
350154-YTG-C-0808
COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
CZH03611
FC62D + MV12D
ID CFM
ID DB (°F)
ID WB (°F)
T.C.
750
800
75
850
CONDENSER
ENTERING AIR
TEMPERATURE
80
57
80
62
75
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
75
62
80
67
80
72
62
25.4 26.8 27.2 29.7 32.8 25.9 27.0 27.3 30.1 33.0 26.4 27.2 27.5 30.4 33.2
25.0 22.9 19.4 19.3 15.3 25.6 23.7 19.9 19.8 15.7 26.1 24.6 20.4 20.2 16.1
1.00 0.99 0.99 0.96 0.93 0.99 0.98 0.98 0.95 0.92 0.97 0.97 0.97 0.94 0.91
24.3 25.5 25.7 28.3 31.2 24.9 25.7 25.9 28.6 31.3 25.4 26.0 26.1 28.9 31.5
24.0 22.3 18.8 18.7 14.8 24.6 23.1 19.4 19.2 15.3 25.1 23.8 19.9 19.7 15.7
1.24 1.23 1.23 1.20 1.17 1.22 1.22 1.22 1.19 1.16 1.21 1.21 1.21 1.18 1.16
23.3 24.2 24.3 26.9 29.5 23.8 24.5 24.5 27.2 29.7 24.3 24.7 24.8 27.5 29.8
23.0 21.8 18.3 18.2 14.4 23.6 22.4 18.8 18.7 14.9 24.1 23.0 19.3 19.2 15.3
1.47 1.47 1.47 1.44 1.41 1.46 1.46 1.46 1.43 1.41 1.45 1.45 1.45 1.42 1.40
22.2 22.9 22.8 25.4 27.9 22.7 23.2 23.1 25.8 28.0 23.3 23.5 23.4 26.1 28.2
22.0 21.2 17.7 17.6 14.0 22.6 21.7 18.2 18.2 14.5 23.1 22.2 18.8 18.7 14.9
1.71 1.71 1.71 1.68 1.65 1.70 1.70 1.70 1.67 1.65 1.69 1.69 1.69 1.66 1.64
20.8 21.3 21.0 23.6 26.0 21.3 21.7 21.3 23.8 26.1 21.9 22.1 21.5 24.1 26.2
20.6 20.0 16.8 16.8 13.4 21.2 20.5 17.4 17.4 13.7 21.7 21.0 17.9 17.9 14.1
2.03 2.03 2.03 2.01 1.98 2.02 2.02 2.02 2.00 1.97 2.00 2.01 2.01 1.99 1.97
19.4 19.7 19.3 21.7 24.1 20.0 20.2 19.5 22.0 24.2 20.5 20.7 19.7 22.2 24.3
19.2 18.8 16.0 16.1 12.8 19.8 19.3 16.6 16.6 13.0 20.4 19.8 17.1 17.1 13.3
2.34 2.33 2.34 2.32 2.30 2.33 2.33 2.33 2.31 2.29 2.31 2.32 2.32 2.30 2.28
18.0 18.2 17.5 19.9 22.2 18.6 18.8 17.7 20.1 22.3 19.1 19.3 18.0 20.4 22.4
17.8 17.6 15.2 15.3 12.2 18.4 18.1 15.8 15.8 12.3 19.0 18.5 16.4 16.3 12.5
2.65 2.64 2.65 2.63 2.62 2.64 2.64 2.65 2.63 2.61 2.62 2.63 2.64 2.62 2.60
65
75
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
115
125
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
S.C.
K.W.
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
LOW CFM
T.C.
S.C.
KW
Variable Speed
Furnace
Air Handler
AV36C
Coil
T.C.
S.C.
KW
Coil
–
1.00
1.00
1.00
1.00
1.00
1.00
1.01
1.01
1.01
1.00
1.00
1.00
1.01
1.00
0.99
0.99
1.00
0.99
0.99
1.01
1.01
1.01
1.00
1.00
1.00
1.01
1.01
1.03
1.03
1.03
1.00
1.00
1.01
1.01
1.01
1.01
1.01
1.00
1.01
PV8*A12
FC/MC/PC37A
FC/MC/PC37A
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
FC/MC/PC48D
UC48D
0.99
1.00
0.99
0.99
0.96
1.00
1.00
1.00
1.00
1.00
0.96
0.96
0.96
1.01
1.01
1.01
1.01
1.01
1.01
1.01
0.99
0.99
0.99
0.99
0.96
1.00
0.99
0.99
1.00
1.00
0.96
0.96
0.96
1.01
1.01
1.01
1.01
1.01
1.01
1.01
1.03
1.04
1.02
1.02
1.00
1.02
1.03
1.03
1.01
1.03
0.98
0.98
0.98
1.00
1.00
1.00
0.99
0.99
0.99
1.02
MV12B
MV12B
MV16C
MV12D
MV12D
MV16C
MV16C
MV16C
MV20D
MV20D
MV12D
MV20D
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48D
UC48D
PV9*A12
PV8*B16
PV8*B16
PV8*C16
PV8*C20
FC/MC/PC48C
FC/MC/PC48D
UC48D
P(C,V)9*B12
P(C,V)9*B12
P(C,V)9*C16
P(C,V)9*C20
PV8*C16
FC/MC/PC48D
UC48D
FC/MC62D
FC/MC62D
PV8*C16
PV8*C16
PV8*C20
FC/MC/PC48C
FC/MC/PC48D
UC48D
PV8*C20
PV8*C20
P(C,V)9*C16
P(C,V)9*C16
P(C,V)9*C16
P(C,V)9*C20
FC/MC/PC48C
FC/MC/PC48D
UC48D
FC/MC/PC48C
Continued on Page 18.
Johnson Controls Unitary Products
17
350154-YTG-C-0808
Variable Speed
Furnace
Variable Speed
Furnace
T.C.
S.C.
KW
T.C.
S.C.
KW
Coil
Coil
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
PV8*C20
FC/MC/PC48D
UC48D
1.01
1.01
1.01
1.01
1.01
1.01
1.01
0.96
1.00
1.00
1.00
0.96
0.98
0.98
1.01
0.98
0.96
0.97
0.96
0.97
0.98
0.98
0.99
0.96
0.95
0.97
0.98
0.98
0.97
0.97
0.97
0.97
0.98
0.99
0.97
0.98
0.97
1.00
0.97
1.00
0.97
0.98
0.97
0.98
0.98
0.97
0.99
0.97
0.96
0.99
0.97
1.01
1.01
1.01
1.01
1.01
1.01
1.01
0.96
1.00
0.99
1.00
0.93
0.97
0.97
1.07
0.98
0.94
0.96
0.93
0.97
0.97
0.97
1.02
0.94
0.89
0.94
0.98
0.98
0.95
0.94
0.95
0.94
0.98
0.98
0.95
0.98
0.94
1.00
0.94
1.00
0.95
0.98
0.95
0.98
0.98
0.95
0.99
0.93
0.92
0.98
0.94
1.02
1.02
1.01
1.01
1.01
1.02
1.02
0.99
1.01
1.01
1.03
1.03
1.05
1.03
1.07
1.03
1.03
1.05
1.02
1.04
1.02
1.02
1.05
1.02
1.02
1.02
1.04
1.02
1.01
1.02
1.02
1.03
1.04
1.03
1.01
1.04
1.02
1.02
1.01
1.03
1.02
1.03
1.01
1.04
1.02
1.02
1.02
1.01
1.02
1.02
1.02
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*A12
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*A12
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*C16
G*9V*C20
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*A12
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*C16
G*9V*C20
UC36A
0.95
0.94
0.96
0.96
0.96
0.98
0.95
0.96
0.97
0.97
0.96
0.96
0.96
0.98
0.95
0.98
0.97
0.98
0.98
0.96
0.96
0.97
0.99
0.96
0.98
0.98
0.97
0.97
0.98
0.98
0.97
1.00
0.97
0.98
0.98
0.96
0.99
0.97
0.94
0.96
0.98
0.95
0.97
0.96
0.96
0.98
0.97
0.95
0.91
0.95
0.95
0.95
1.00
0.92
0.94
0.96
0.97
0.94
0.93
0.94
0.99
0.93
0.99
0.95
0.97
0.98
0.94
0.94
0.97
1.02
0.94
0.97
0.98
0.94
0.95
0.98
0.98
0.94
1.00
0.95
0.98
0.98
0.92
0.98
0.94
0.92
0.95
1.00
0.92
0.96
0.93
0.94
0.99
0.95
1.05
1.02
1.04
1.02
1.02
1.05
1.02
1.02
1.04
1.02
1.01
1.02
1.02
1.02
1.01
1.03
1.03
1.05
1.03
1.03
1.05
1.04
1.05
1.02
1.06
1.04
1.02
1.02
1.04
1.04
1.02
1.03
1.02
1.04
1.02
1.02
1.02
1.02
1.05
1.04
1.05
1.02
1.04
1.02
1.02
1.03
1.03
UC36B
FC/MC/PC48D
UC48D
UC36B
UC36C
FC/MC62D
FC/MC62D
FC/MC62D
HC42C
UC36C
P(C,V)9*C20
P(C,V)9*D20
PV8*C16
UC36C
UC36C
UC42B
PV8*C20
HC42C
UC42B
P(C,V)9*C16
P(C,V)9*C20
Y*(8,L)C*B12
Y*9C*B12
HC42C
UC42C
HC42C
UC42C
FC/MC/PC35B
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC36A
FC/MC/PC36B
FC/MC/PC36B
FC/MC/PC36C
FC/MC/PC36C
FC/MC/PC36C
FC/MC/PC36C
FC/MC/PC37A
FC/MC/PC42B
FC/MC/PC42B
FC/MC/PC42C
FC/MC/PC42C
FC/MC/PC42C
FC/MC/PC42C
FC/MC/PC43B
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
HC42
UC42C
UC42C
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
UC48C
UC48C
UC48C
Y*9C*C20
UC48C
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC36A
FC/MC/PC36B
FC/MC/PC36C
FC/MC/PC36C
FC/MC/PC37A
FC/MC/PC42B
FC/MC/PC42C
FC/MC/PC42C
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
FC/MC/PC48C
HC42
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
HC42
HD48
Y*9C*C20
HD48
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
HD48
UC36A
UC36B
Y*9C*C20
UC36C
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
UC36C
HC42
UC42B
HC42
UC42C
Y*9C*C20
HC42
UC42C
Y*(8,L)C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*B12
HD48
UC48C
HD48
UC48C
HD48
HD48
Y*9C*C16
HD48
Y*9C*C20
HD48
18
Johnson Controls Unitary Products
350154-YTG-C-0808
COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
CZH03611
FC62D + MV12D
ID CFM
ID DB (°F)
ID WB (°F)
T.C.
1100
1200
75
1300
CONDENSER
ENTERING AIR
TEMPERATURE
80
57
80
62
75
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
75
62
80
67
80
72
62
35.7 38.1 38.5 41.2 45.8 37.2 39.1 38.8 41.7 46.1 38.6 40.1 39.1 42.1 46.3
34.5 31.9 27.3 26.9 21.2 36.1 33.4 28.6 27.7 22.1 37.5 35.0 29.9 28.4 22.9
1.71 1.74 1.74 1.79 1.82 1.74 1.76 1.76 1.81 1.84 1.78 1.79 1.78 1.84 1.86
34.6 36.5 36.7 39.5 43.6 35.9 37.4 37.1 40.0 43.9 37.1 38.2 37.5 40.4 44.2
33.6 31.1 26.5 26.0 20.6 34.8 32.6 27.6 27.0 21.4 36.0 34.1 28.8 27.9 22.1
1.98 2.00 2.00 2.05 2.07 2.00 2.02 2.01 2.06 2.09 2.04 2.05 2.04 2.09 2.12
33.6 35.0 35.0 37.8 41.5 34.6 35.7 35.4 38.3 41.8 35.5 36.4 35.9 38.7 42.0
32.6 30.3 25.6 25.2 20.0 33.6 31.8 26.6 26.3 20.6 34.5 33.3 27.7 27.4 21.2
2.24 2.26 2.25 2.30 2.33 2.26 2.28 2.27 2.32 2.35 2.30 2.30 2.30 2.34 2.38
32.5 33.4 33.2 36.1 39.4 33.3 34.0 33.7 36.6 39.6 34.0 34.5 34.2 37.1 39.8
31.6 29.4 24.7 24.3 19.4 32.3 31.0 25.6 25.6 19.9 33.0 32.4 26.6 26.9 20.3
2.50 2.52 2.51 2.55 2.59 2.52 2.53 2.53 2.57 2.60 2.56 2.56 2.56 2.59 2.63
30.7 31.5 31.2 33.7 37.0 31.5 32.0 31.6 34.2 37.2 32.1 32.6 32.0 34.7 37.4
29.9 28.4 23.7 23.6 18.6 30.6 29.6 24.7 24.8 19.0 31.3 30.6 25.7 25.9 19.4
2.89 2.90 2.90 2.94 2.97 2.92 2.92 2.91 2.96 2.99 2.95 2.95 2.94 2.98 3.02
29.0 29.6 29.2 31.3 34.7 29.7 30.2 29.5 31.8 34.9 30.4 30.7 29.8 32.3 35.0
28.3 27.5 22.8 22.9 17.9 29.0 28.2 23.8 23.9 18.2 29.6 28.9 24.8 24.9 18.5
3.28 3.28 3.27 3.32 3.35 3.30 3.29 3.29 3.33 3.37 3.33 3.32 3.31 3.35 3.40
27.3 27.7 27.2 29.0 32.4 28.0 28.3 27.4 29.5 32.6 28.6 28.8 27.7 30.0 32.7
26.7 26.5 21.9 22.2 17.2 27.3 26.8 22.9 23.1 17.4 28.0 27.1 24.0 24.0 17.6
3.66 3.65 3.65 3.70 3.73 3.68 3.67 3.66 3.71 3.75 3.71 3.70 3.69 3.73 3.78
65
75
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
115
125
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
S.C.
K.W.
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HIGH CFM
T.C.
S.C.
KW
Variable Speed
Furnace
Air Handler
AV36C
Coil
T.C.
S.C.
KW
Coil
–
0.97
0.98
0.98
0.99
0.98
0.98
0.99
0.99
0.99
1.00
1.00
1.00
1.01
0.97
0.98
0.98
0.99
0.98
0.98
0.99
0.99
0.99
1.00
1.00
1.00
1.01
1.03
1.03
1.03
1.01
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
PV8*A12
FC/MC/PC37A
FC/MC/PC37A
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
FC/MC/PC48D
UC48D
0.98
0.97
0.98
0.98
0.99
0.98
0.97
0.97
0.98
0.98
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.98
0.97
0.98
0.98
0.99
0.98
0.97
0.97
0.98
0.98
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
1.05
1.07
1.02
1.02
1.02
1.04
1.05
1.05
1.02
1.03
1.01
1.01
1.01
1.04
1.04
1.04
1.02
1.02
1.02
1.03
MV12B
MV12B
MV16C
MV12D
MV12D
MV16C
MV16C
MV16C
MV20D
MV20D
MV12D
MV20D
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48D
UC48D
PV9*A12
PV8*B16
PV8*B16
PV8*C16
PV8*C20
FC/MC/PC48C
FC/MC/PC48D
UC48D
P(C,V)9*B12
P(C,V)9*B12
P(C,V)9*C16
P(C,V)9*C20
PV8*C16
FC/MC/PC48D
UC48D
FC/MC62D
FC/MC62D
PV8*C16
PV8*C16
PV8*C20
FC/MC/PC48C
FC/MC/PC48D
UC48D
PV8*C20
PV8*C20
P(C,V)9*C16
P(C,V)9*C16
P(C,V)9*C16
P(C,V)9*C20
FC/MC/PC48C
FC/MC/PC48D
UC48D
FC/MC/PC48C
Continued on Page 20.
Johnson Controls Unitary Products
19
350154-YTG-C-0808
Variable Speed
Furnace
Variable Speed
Furnace
T.C.
S.C.
KW
T.C.
S.C.
KW
Coil
Coil
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
PV8*C20
FC/MC/PC48D
UC48D
0.99
0.99
0.99
0.99
1.00
1.00
1.01
0.99
0.98
0.98
0.98
0.97
0.97
0.98
0.97
0.98
0.98
0.95
0.96
0.96
0.96
0.96
0.96
0.97
0.95
0.96
0.96
0.98
0.97
0.96
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.99
0.99
0.99
0.99
1.00
1.00
1.00
0.99
0.98
0.98
0.98
0.96
0.97
0.97
0.96
0.97
1.00
0.94
0.96
0.94
0.95
0.95
0.95
0.99
0.90
0.95
0.96
0.98
0.96
0.96
1.01
0.98
0.98
0.99
0.99
0.99
0.99
0.99
0.98
0.99
1.02
0.98
0.98
0.98
0.98
0.98
0.98
0.97
0.96
0.98
1.03
1.03
1.02
1.02
1.04
1.03
1.02
1.02
1.04
1.02
1.03
1.07
1.07
1.04
1.02
1.04
1.07
1.07
1.05
1.05
1.03
1.02
1.03
1.06
1.03
1.03
1.07
1.01
1.00
1.03
1.05
1.07
1.07
1.03
1.02
1.06
1.03
1.02
1.01
1.04
1.06
1.03
1.02
1.06
1.04
1.05
1.02
1.01
1.06
1.03
Y*9C*C20
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*A12
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*A12
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*C16
G*9V*C20
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*A12
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*C16
G*9V*C20
HD48
0.98
0.94
0.95
0.95
0.95
0.95
0.95
0.96
0.96
0.95
0.97
0.97
0.96
0.98
0.98
0.98
0.98
0.98
0.97
0.98
0.98
0.95
0.96
0.96
0.97
0.96
0.96
0.96
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.94
0.95
0.95
0.96
0.95
0.96
0.98
0.98
0.98
1.01
0.92
0.94
0.93
0.93
0.93
0.93
0.98
0.95
0.95
0.96
0.95
0.95
0.99
0.99
0.98
0.99
1.02
0.97
0.97
1.00
0.94
0.94
0.95
0.99
0.94
0.96
0.96
1.01
0.98
0.99
0.99
0.99
1.02
0.98
0.98
0.96
0.98
1.01
0.93
0.93
0.93
0.98
0.95
0.95
0.99
0.99
1.02
1.06
1.07
1.05
1.04
1.03
1.02
1.03
1.06
1.03
1.07
1.01
1.00
1.03
1.05
1.02
1.01
1.03
1.06
1.07
1.04
1.07
1.08
1.05
1.03
1.06
1.06
1.07
1.03
1.05
1.07
1.06
1.03
1.04
1.06
1.06
1.04
1.06
1.03
1.06
1.07
1.04
1.03
1.06
1.07
1.03
1.05
1.03
1.06
UC36A
FC/MC/PC48D
UC48D
UC36B
UC36B
FC/MC62D
FC/MC62D
FC/MC62D
HC42C
UC36C
P(C,V)9*C20
P(C,V)9*D20
PV8*C16
UC36C
UC36C
UC36C
PV8*C20
HC42C
UC42B
P(C,V)9*C16
P(C,V)9*C20
Y*(8,L)C*B12
Y*9C*B12
HC42C
UC42B
HC42C
UC42C
FC/MC/PC35B
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC36A
FC/MC/PC36B
FC/MC/PC36B
FC/MC/PC36C
FC/MC/PC36C
FC/MC/PC36C
FC/MC/PC36C
FC/MC/PC37A
FC/MC/PC42B
FC/MC/PC42B
FC/MC/PC42C
FC/MC/PC42C
FC/MC/PC42C
FC/MC/PC42C
FC/MC/PC43B
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
HC42
UC42C
UC42C
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
UC42C
UC48C
UC48C
Y*9C*C20
UC48C
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
UC48C
FC/MC/PC35B
FC/MC/PC35C
FC/MC/PC35C
FC/MC/PC36A
FC/MC/PC36B
FC/MC/PC36C
FC/MC/PC36C
FC/MC/PC37A
FC/MC/PC42B
FC/MC/PC42C
FC/MC/PC42C
FC/MC/PC43B
FC/MC/PC43C
FC/MC/PC43C
FC/MC/PC48C
FC/MC/PC48C
HC42
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
HC42
Y*9C*C20
HD48
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
HD48
HD48
UC36A
Y*9C*C20
UC36B
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
UC36C
HC42
UC36C
HC42
UC42B
Y*9C*C20
HC42
UC42C
Y*(8,L)C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*B12
HD48
UC42C
HD48
UC48C
HD48
UC48C
HD48
Y*9C*C16
HD48
20
Johnson Controls Unitary Products
350154-YTG-C-0808
COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
CZH04811
FC62D + MV20D
ID CFM
ID DB (°F)
ID WB (°F)
T.C.
950
1000
75
1050
CONDENSER
ENTERING AIR
TEMPERATURE
80
57
80
62
75
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
75
62
80
67
80
72
62
35.4 36.6 36.2 39.8 42.3 36.1 37.2 36.8 40.2 42.9 36.8 37.8 37.4 40.6 43.4
34.3 31.8 26.9 27.2 21.7 34.8 32.5 27.6 27.8 22.0 35.3 33.3 28.2 28.5 22.3
1.50 1.50 1.49 1.48 1.48 1.50 1.49 1.49 1.48 1.47 1.49 1.49 1.49 1.47 1.47
34.0 34.9 34.5 37.8 40.4 34.6 35.4 35.0 38.2 40.9 35.2 36.0 35.5 38.6 41.5
32.9 31.0 26.2 26.4 21.0 33.4 31.7 26.8 27.0 21.3 33.9 32.4 27.4 27.6 21.7
1.81 1.81 1.81 1.80 1.79 1.81 1.81 1.80 1.79 1.78 1.80 1.80 1.80 1.79 1.78
32.5 33.1 32.8 35.7 38.5 33.1 33.7 33.2 36.2 39.0 33.7 34.2 33.6 36.6 39.5
31.5 30.2 25.5 25.5 20.3 32.0 30.9 26.0 26.1 20.7 32.5 31.6 26.6 26.7 21.1
2.12 2.12 2.12 2.11 2.10 2.12 2.12 2.12 2.11 2.10 2.12 2.12 2.11 2.11 2.09
31.1 31.4 31.1 33.7 36.6 31.7 31.9 31.4 34.2 37.1 32.2 32.4 31.7 34.6 37.6
30.1 29.4 24.8 24.7 19.6 30.6 30.1 25.3 25.3 20.0 31.1 30.8 25.8 25.8 20.4
2.44 2.44 2.44 2.43 2.41 2.43 2.43 2.43 2.43 2.41 2.43 2.43 2.43 2.42 2.40
29.4 29.7 28.9 31.5 34.2 30.0 30.2 29.3 31.9 34.6 30.5 30.7 29.6 32.3 35.0
28.5 27.8 23.8 23.8 18.7 28.9 28.5 24.3 24.4 19.1 29.4 29.1 24.8 24.9 19.6
2.86 2.87 2.87 2.87 2.84 2.86 2.86 2.86 2.86 2.84 2.86 2.86 2.86 2.85 2.84
27.8 28.0 26.9 29.3 31.9 28.4 28.6 27.2 29.7 32.2 28.9 29.1 27.6 30.1 32.5
26.9 26.3 22.9 23.0 17.8 27.4 26.9 23.4 23.5 18.3 27.8 27.5 23.9 24.1 18.7
3.28 3.28 3.29 3.29 3.26 3.27 3.28 3.28 3.27 3.26 3.27 3.27 3.28 3.27 3.26
26.2 26.4 24.8 27.1 29.6 26.7 26.9 25.2 27.5 29.8 27.2 27.5 25.6 27.9 30.0
25.4 24.8 21.9 22.1 16.9 25.8 25.4 22.4 22.7 17.4 26.2 26.0 22.9 23.3 17.9
3.69 3.70 3.71 3.71 3.67 3.69 3.69 3.70 3.69 3.67 3.69 3.69 3.70 3.68 3.68
65
75
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
115
125
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
S.C.
K.W.
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
LOW CFM
T.C.
S.C.
KW
Air Handler
AV/SV48D
AV/SV60D
F4FV060
MV16C
Coil
–
0.97
0.97
0.99
1.00
1.00
1.00
1.00
1.00
1.00
0.97
0.97
0.98
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.01
0.99
0.99
0.99
1.00
1.00
1.00
–
–
FC/MC/PC48C
FC/MC/PC48D
UC48D
MV16C
MV16C
MV20D
FC/MC/PC48D
UC48D
MV20D
MV20D
FC/MC62D
Continued on Page 22.
Johnson Controls Unitary Products
21
350154-YTG-C-0808
Variable Speed
Furnace
Variable Speed
T.C.
S.C.
KW
Coil
T.C.
S.C.
KW
Coil
Furnace
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*9C*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*D20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
HD60
1.01
1.01
1.00
1.01
1.00
0.95
0.95
0.95
0.95
0.89
0.90
0.90
0.90
0.90
0.90
1.00
1.00
0.99
0.97
0.99
0.97
0.98
0.96
0.99
0.99
0.98
1.00
1.01
1.00
0.95
0.95
0.89
0.90
0.90
0.90
1.00
1.00
1.00
1.00
1.00
0.95
0.95
0.96
0.97
0.90
0.87
0.87
0.87
0.87
0.87
1.00
1.00
0.98
0.96
0.99
0.96
0.97
0.96
0.97
0.97
0.97
1.00
1.00
1.00
0.96
0.97
0.90
0.87
0.87
0.87
1.01
1.00
1.02
1.02
1.02
1.02
1.03
1.03
1.02
1.03
1.02
1.01
1.03
1.03
1.03
1.02
1.02
1.02
1.02
1.02
1.02
1.02
1.03
1.02
1.02
1.02
1.02
1.02
1.02
1.03
1.02
1.03
1.03
1.03
1.03
PV8*C16
FC/MC/PC48C
FC/MC/PC48D
UC48D
0.97
0.97
0.97
1.00
1.00
1.00
1.01
1.01
1.01
0.99
0.99
0.99
0.99
0.99
1.00
1.00
0.99
0.95
1.00
1.00
1.00
1.00
0.99
0.97
0.99
0.98
0.98
0.97
0.98
0.96
0.98
0.98
0.99
0.99
0.98
0.97
0.97
0.97
1.00
1.00
1.00
1.02
1.02
1.02
0.99
0.99
0.99
0.99
0.99
1.00
1.00
0.99
0.95
0.99
0.99
1.00
1.00
0.98
0.96
0.99
0.97
0.97
0.96
0.97
0.96
0.97
0.97
0.97
0.97
0.97
0.98
0.98
0.98
0.99
0.99
0.99
0.98
0.98
0.98
1.00
1.00
1.00
1.00
1.00
0.99
1.00
1.00
1.00
1.02
1.02
1.02
1.02
1.02
1.02
1.02
1.01
1.01
1.02
1.02
1.03
1.02
1.02
1.02
1.02
1.02
HD60
PV8*C16
HD60
PV8*C16
HD60
PV8*C20
FC/MC/PC48C
FC/MC/PC48D
UC48D
HD60
PV8*C20
UC48C
UC48C
UC48C
UC48C
UC48D
UC60C
UC60C
UC60C
UC60C
UC60D
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48D
FC/MC/PC60D
FC/MC62D
FC/PC60C
FC/PC60C
HC60
PV8*C20
P(C,V)9*C16
P(C,V)9*C16
P(C,V)9*C16
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
PV8*C20
FC/MC/PC48C
FC/MC/PC48D
UC48D
FC/MC/PC48C
FC/MC/PC48D
UC48D
FC/MC/PC48D
UC48D
FC/MC62D
FC/MC62D
FC/MC62D
HC60D
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48D
FC/MC/PC60D
FC/MC62D
FC/PC60C
FC/PC60C
FC/PC60C
FC/PC60C
HC60
Y*9C*C20
Y*9C*D20
HD48
Y*9C*D20
HD48
Y*9C*D20
HD48
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
HD60
HD60
HD60
Y*9C*C20
UC48C
UC48C
UC48D
UC60C
UC60C
UC60D
Y*9C*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
HD48
HD48
HD48
Y*9C*C20
HD48
Y*9C*D20
HD48
22
Johnson Controls Unitary Products
350154-YTG-C-0808
COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
CZH04811
FC62D + MV20D
ID CFM
ID DB (°F)
ID WB (°F)
T.C.
1500
1600
75
1700
CONDENSER
ENTERING AIR
TEMPERATURE
80
57
80
62
75
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
75
62
80
67
80
72
62
48.7 49.9 49.0 53.2 56.4 49.6 50.4 49.5 54.4 56.8 50.5 50.9 50.0 55.5 57.2
48.0 44.9 38.2 37.9 29.7 48.9 46.3 39.1 39.0 30.3 49.7 47.6 40.0 40.1 30.9
2.53 2.57 2.56 2.64 2.71 2.58 2.61 2.61 2.67 2.75 2.64 2.67 2.66 2.72 2.79
46.8 47.7 46.8 50.9 53.6 47.6 48.2 47.2 51.8 54.0 48.3 48.8 47.6 52.5 54.4
46.2 43.8 37.1 36.8 28.7 46.9 45.0 38.0 37.9 29.3 47.6 46.2 38.9 38.9 29.9
2.89 2.91 2.90 2.98 3.05 2.93 2.96 2.95 3.02 3.09 2.99 3.01 3.00 3.07 3.15
45.0 45.5 44.5 48.6 50.9 45.6 46.1 44.9 49.1 51.3 46.2 46.6 45.2 49.6 51.6
44.3 42.6 35.9 35.7 27.8 44.9 43.7 36.9 36.7 28.4 45.6 44.8 37.8 37.7 28.9
3.24 3.26 3.25 3.33 3.40 3.29 3.31 3.29 3.37 3.44 3.34 3.36 3.34 3.42 3.50
43.1 43.4 42.2 46.3 48.2 43.5 43.9 42.5 46.5 48.5 44.0 44.4 42.9 46.6 48.8
42.4 41.5 34.8 34.6 26.9 43.0 42.4 35.7 35.6 27.4 43.5 43.3 36.7 36.5 27.9
3.59 3.61 3.60 3.68 3.75 3.64 3.66 3.64 3.72 3.79 3.69 3.71 3.69 3.77 3.85
40.7 41.0 39.6 43.5 45.2 41.2 41.5 39.9 43.7 45.4 41.6 41.9 40.1 43.9 45.6
40.1 39.3 33.5 33.5 25.8 40.6 40.1 34.4 34.4 26.3 41.1 40.8 35.4 35.3 26.8
4.10 4.12 4.10 4.18 4.25 4.15 4.16 4.14 4.22 4.29 4.21 4.22 4.19 4.27 4.35
38.5 38.7 37.2 40.7 42.4 38.9 39.1 37.3 40.9 42.5 39.3 39.5 37.4 41.2 42.5
37.9 37.2 32.3 32.4 24.9 38.4 37.8 33.2 33.3 25.3 38.8 38.4 34.1 34.2 25.7
4.60 4.60 4.58 4.67 4.74 4.65 4.65 4.62 4.71 4.78 4.70 4.71 4.67 4.76 4.83
36.2 36.4 34.7 37.9 39.6 36.6 36.8 34.7 38.2 39.6 36.9 37.1 34.7 38.4 39.5
35.7 35.1 31.1 31.3 23.9 36.1 35.6 32.0 32.2 24.3 36.5 36.0 32.8 33.1 24.6
5.09 5.09 5.07 5.16 5.23 5.14 5.14 5.11 5.20 5.27 5.20 5.21 5.16 5.25 5.32
65
75
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
115
125
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
S.C.
K.W.
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HIGH CFM
T.C.
S.C.
KW
Air Handler
AV/SV48D
AV/SV60D
F4FV060
MV16C
Coil
–
0.96
0.96
0.96
0.99
0.99
0.99
0.99
0.99
1.00
0.96
0.96
0.96
0.99
0.99
0.99
0.99
0.99
1.00
0.99
0.99
0.98
0.99
0.99
0.99
1.00
1.00
1.00
–
–
FC/MC/PC48C
FC/MC/PC48D
UC48D
MV16C
MV16C
MV20D
FC/MC/PC48D
UC48D
MV20D
MV20D
FC/MC62D
Continued on Page 24.
Johnson Controls Unitary Products
23
350154-YTG-C-0808
Variable Speed
Furnace
Variable Speed
T.C.
S.C.
KW
Coil
T.C.
S.C.
KW
Coil
Furnace
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*9C*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*D20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
G*9V*C16
G*9V*C20
G*9V*D20
HD60
1.00
1.00
1.00
1.00
1.00
0.97
0.96
0.96
0.96
0.92
0.93
0.93
0.92
0.92
0.93
1.00
1.00
0.99
0.98
0.99
0.98
0.98
0.97
0.99
0.99
1.00
1.00
1.00
1.00
0.96
0.96
0.92
0.92
0.92
0.93
1.00
1.01
1.00
1.00
1.00
0.97
0.96
0.96
0.96
0.90
0.90
0.91
0.90
0.90
0.90
0.99
0.99
0.98
0.98
0.98
0.98
0.98
0.97
0.97
0.97
0.97
1.00
1.00
1.00
0.96
0.96
0.90
0.90
0.90
0.90
1.03
1.01
1.04
1.04
1.04
1.03
1.03
1.03
1.04
1.03
1.02
1.00
1.03
1.03
1.02
1.04
1.04
1.04
1.03
1.03
1.04
1.04
1.03
1.04
1.04
1.04
1.04
1.04
1.04
1.03
1.04
1.03
1.03
1.03
1.02
PV8*C16
FC/MC/PC48C
FC/MC/PC48D
UC48D
0.97
0.97
0.97
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.99
0.99
0.99
0.95
1.00
1.00
1.00
1.00
0.99
0.98
0.99
0.98
0.99
0.98
0.98
0.97
1.00
1.00
0.99
0.99
1.00
0.97
0.97
0.97
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.99
0.99
0.99
0.95
1.00
1.00
0.99
0.99
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.97
0.98
0.98
0.97
0.97
0.97
1.01
1.01
1.01
1.02
1.02
1.02
1.03
1.03
1.03
1.02
1.02
1.02
1.00
1.00
1.01
1.02
1.01
1.00
1.04
1.04
1.04
1.04
1.04
1.03
1.03
1.03
1.01
1.04
1.04
1.03
1.03
1.04
1.04
1.04
1.04
HD60
PV8*C16
HD60
PV8*C16
HD60
PV8*C20
FC/MC/PC48C
FC/MC/PC48D
UC48D
HD60
PV8*C20
UC48C
UC48C
UC48C
UC48C
UC48D
UC60C
UC60C
UC60C
UC60C
UC60D
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48D
FC/MC/PC60D
FC/MC62D
FC/PC60C
FC/PC60C
HC60
PV8*C20
P(C,V)9*C16
P(C,V)9*C16
P(C,V)9*C16
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
PV8*C20
FC/MC/PC48C
FC/MC/PC48D
UC48D
FC/MC/PC48C
FC/MC/PC48D
UC48D
FC/MC/PC48D
UC48D
FC/MC62D
FC/MC62D
FC/MC62D
HC60D
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48C
FC/MC/PC48D
FC/MC/PC60D
FC/MC62D
FC/PC60C
FC/PC60C
FC/PC60C
FC/PC60C
HC60
Y*9C*C20
Y*9C*D20
HD48
Y*9C*D20
HD48
Y*9C*D20
HD48
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
HD60
HD60
HD60
Y*9C*C20
UC48C
UC48C
UC48D
UC60C
UC60C
UC60D
Y*9C*D20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
HD48
HD48
HD48
Y*9C*C20
HD48
Y*9C*D20
HD48
24
Johnson Controls Unitary Products
350154-YTG-C-0808
COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
CZH06011
FC62D + MV20D
ID CFM
ID DB (°F)
ID WB (°F)
T.C.
1100
1150
75
1200
CONDENSER
ENTERING AIR
TEMPERATURE
80
57
80
62
75
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
75
62
80
67
80
72
62
38.1 44.0 43.9 47.7 52.4 39.7 44.2 44.3 48.1 53.0 41.4 44.3 44.7 48.5 53.5
37.2 35.7 30.6 30.0 24.5 38.8 36.5 31.2 30.6 24.9 40.4 37.3 31.7 31.2 25.3
3.20 1.94 1.94 1.91 1.92 2.79 1.94 1.94 1.91 1.90 2.37 1.95 1.94 1.92 1.88
37.5 42.0 42.0 45.7 50.2 39.2 42.4 42.3 46.1 50.8 40.8 42.8 42.7 46.5 51.3
36.6 35.0 29.8 29.4 23.8 38.2 35.8 30.4 30.0 24.2 39.8 36.6 30.9 30.6 24.6
3.20 2.36 2.36 2.33 2.34 2.78 2.36 2.36 2.34 2.32 2.37 2.37 2.36 2.35 2.31
37.0 40.1 40.0 43.8 48.1 38.6 40.7 40.4 44.2 48.6 40.2 41.3 40.7 44.5 49.1
36.1 34.2 29.0 28.7 23.1 37.7 35.0 29.6 29.3 23.5 39.2 35.8 30.1 29.9 23.8
3.20 2.78 2.78 2.75 2.76 2.78 2.78 2.78 2.76 2.75 2.37 2.78 2.78 2.77 2.74
36.5 38.2 38.1 41.9 45.9 38.1 39.0 38.4 42.2 46.4 39.7 39.8 38.7 42.5 46.9
35.6 33.5 28.2 28.1 22.4 37.1 34.3 28.8 28.7 22.7 38.7 35.0 29.3 29.2 23.1
3.20 3.19 3.20 3.17 3.17 2.78 3.20 3.20 3.18 3.17 2.37 3.20 3.20 3.19 3.17
34.2 35.5 35.3 38.8 42.7 35.4 36.1 35.6 39.1 43.1 36.6 36.7 35.8 39.3 43.5
33.4 31.9 26.7 26.8 21.0 34.6 32.6 27.3 27.3 21.4 35.7 33.2 27.8 27.8 21.8
3.76 3.75 3.75 3.73 3.73 3.48 3.75 3.75 3.74 3.73 3.20 3.76 3.76 3.75 3.74
32.0 32.9 32.6 35.8 39.7 32.8 33.3 32.9 36.0 39.9 33.5 33.7 33.1 36.3 40.2
31.3 30.4 25.3 25.4 19.7 32.0 30.9 25.9 25.9 20.1 32.8 31.5 26.4 26.4 20.5
4.30 4.29 4.29 4.28 4.28 4.16 4.29 4.29 4.28 4.28 4.02 4.29 4.29 4.29 4.28
29.9 30.3 30.0 32.7 36.6 30.2 30.5 30.1 33.0 36.7 30.5 30.6 30.3 33.2 36.9
29.2 28.9 23.9 24.1 18.3 29.5 29.3 24.4 24.5 18.8 29.8 29.7 24.9 24.9 19.3
4.84 4.82 4.83 4.83 4.83 4.83 4.83 4.83 4.83 4.83 4.83 4.83 4.83 4.83 4.83
65
75
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
115
125
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
S.C.
K.W.
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
LOW CFM
Variable Speed
T.C.
S.C.
KW
T.C.
S.C.
KW
Air Handler
AV/SV60D
F4FV060
MV20D
Coil
Coil
Furnace
–
0.99
0.99
0.95
0.95
1.00
0.99
0.99
0.95
0.95
1.00
1.00
1.02
1.00
1.00
1.00
P(C,V)9*D20
Y*9C*D20
Y*(8,L)C*C20
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C20
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C20
Y*9C*C20
Y*9C*D20
G*9V*D20
G*9V*C20
G*9V*D20
G*9V*C20
G*9V*D20
G*9V*C20
G*9V*D20
HC60D
FC/MC62D
FC/PC60C
FC/PC60C
HC60
0.95
0.98
0.97
0.97
0.95
0.98
0.98
0.99
0.94
0.93
0.94
0.98
0.97
0.95
0.98
0.99
0.93
0.94
0.95
0.97
0.95
0.95
0.94
0.95
0.97
0.97
0.91
0.90
0.92
0.97
0.95
0.94
0.97
0.97
0.90
0.92
1.00
1.03
1.01
1.02
1.02
1.01
1.03
1.03
1.01
1.02
1.02
1.03
1.02
1.02
1.03
1.03
1.02
1.02
–
FC/MC/PC60D
UC60D
MV20D
MV20D
FC/MC62D
HD60
Variable Speed
Furnace
HD60
T.C.
S.C.
KW
Coil
HD60
PV8*C20
FC/PC60C
FC/MC/PC60D
UC60D
0.97
0.97
0.97
0.96
0.96
0.96
0.95
0.95
1.02
1.01
1.00
0.97
0.97
0.97
0.96
0.96
0.96
0.95
0.95
1.02
1.01
1.00
1.01
1.01
1.01
1.01
1.01
1.01
1.00
1.00
1.01
1.00
1.00
UC60C
UC60C
UC60D
FC/MC62D
FC/PC60C
HC60
PV8*C20
PV8*C20
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
PV8*C20
FC/PC60C
FC/MC/PC60D
UC60D
FC/MC/PC60D
UC60D
HD60
HD60
FC/MC62D
FC/MC62D
FC/MC62D
UC60C
UC60D
P(C,V)9*C20
P(C,V)9*D20
Johnson Controls Unitary Products
25
COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
CZH06011
FC62D + MV20D
ID CFM
ID DB (°F)
ID WB (°F)
T.C.
1750
1850
75
1950
75
CONDENSER
ENTERING AIR
TEMPERATURE
80
57
80
62
75
62
80
67
80
72
80
57
80
62
80
67
80
72
80
57
80
62
80
67
80
72
62
62
57.1 61.0 60.6 66.2 71.1 58.0 61.4 61.2 66.8 72.2 58.8 61.6 61.8 67.3 73.3
58.1 53.7 44.6 44.7 36.4 59.0 54.7 46.2 45.8 36.6 59.8 55.6 47.7 46.8 36.8
3.20 3.25 3.26 3.32 3.36 3.27 3.32 3.31 3.39 3.44 3.36 3.40 3.38 3.47 3.53
55.3 58.5 58.0 63.4 68.2 56.0 58.8 58.4 63.9 68.9 56.7 59.1 58.7 64.3 69.5
56.3 52.5 43.9 43.6 34.8 57.0 53.5 44.9 44.6 34.9 57.7 54.5 45.8 45.6 34.9
3.69 3.74 3.74 3.80 3.86 3.77 3.80 3.79 3.87 3.93 3.85 3.88 3.86 3.95 4.01
53.6 55.9 55.4 60.6 65.3 54.1 56.2 55.5 60.9 65.5 54.6 56.5 55.6 61.2 65.8
54.5 51.3 43.2 42.5 33.1 55.1 52.4 43.6 43.5 33.1 55.6 53.4 44.0 44.4 33.0
4.19 4.23 4.22 4.29 4.35 4.26 4.29 4.28 4.35 4.41 4.34 4.36 4.35 4.43 4.49
51.8 53.3 52.8 57.8 62.4 52.2 53.6 52.7 58.0 62.2 52.6 53.9 52.5 58.2 62.0
52.7 50.1 42.5 41.5 31.5 53.1 51.3 42.4 42.3 31.4 53.5 52.4 42.1 43.2 31.2
4.69 4.71 4.70 4.77 4.84 4.76 4.77 4.76 4.83 4.90 4.83 4.85 4.83 4.91 4.97
48.6 49.8 49.3 53.9 58.3 49.1 50.1 49.3 54.1 58.2 49.5 50.4 49.2 54.2 58.1
49.5 47.7 40.5 39.8 30.1 50.0 48.7 40.7 40.6 30.1 50.4 49.6 40.8 41.3 30.1
5.39 5.40 5.38 5.46 5.54 5.46 5.47 5.44 5.53 5.60 5.54 5.55 5.52 5.60 5.67
45.6 46.3 46.0 50.2 54.3 46.1 46.7 46.0 50.3 54.3 46.5 47.1 46.0 50.4 54.2
46.4 45.4 38.6 38.2 28.7 46.9 46.2 39.0 38.9 29.0 47.4 46.9 39.4 39.6 29.1
6.06 6.07 6.04 6.13 6.22 6.14 6.14 6.11 6.20 6.28 6.23 6.22 6.19 6.28 6.36
42.6 42.8 42.6 46.4 50.3 43.1 43.3 42.7 46.5 50.4 43.5 43.7 42.7 46.5 50.4
43.4 43.2 36.6 36.6 27.4 43.9 43.7 37.4 37.2 27.8 44.3 44.1 38.1 37.8 28.2
6.74 6.75 6.71 6.80 6.89 6.82 6.82 6.78 6.87 6.96 6.91 6.90 6.86 6.96 7.04
65
75
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
85
S.C.
K.W.
T.C.
95
S.C.
K.W.
T.C.
105
115
125
S.C.
K.W.
T.C.
S.C.
K.W.
T.C.
S.C.
K.W.
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HIGH CFM
Variable Speed
T.C.
S.C.
KW
T.C.
S.C.
KW
Air Handler
AV/SV60D
F4FV060
MV20D
Coil
Coil
Furnace
–
0.96
0.96
0.96
0.96
1.00
0.96
0.96
0.96
0.96
1.00
0.99
0.99
0.99
0.99
1.00
Y*9C*D20
Y*(8,L)C*C20
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C20
Y*9C*C20
Y*9C*D20
Y*(8,L)C*C20
Y*9C*C20
Y*9C*D20
G*9V*D20
G*9V*C20
G*9V*D20
G*9V*C20
G*9V*D20
G*9V*C20
G*9V*D20
FC/MC62D
FC/PC60C
FC/PC60C
HC60
0.97
0.96
0.96
0.94
0.97
0.97
0.96
0.94
0.93
0.94
0.97
0.96
0.94
0.97
0.96
0.93
0.94
0.94
0.93
0.93
0.90
0.93
0.94
0.92
0.89
0.89
0.89
0.94
0.93
0.90
0.94
0.92
0.89
0.89
1.02
1.00
1.02
1.01
1.00
1.03
1.02
1.00
1.02
1.01
1.02
1.02
1.01
1.03
1.02
1.02
1.01
–
FC/MC/PC60D
UC60D
MV20D
HD60
MV20D
FC/MC62D
HD60
HD60
Variable Speed
Furnace
PV8*C20
T.C.
S.C.
KW
UC60C
UC60C
UC60D
FC/MC62D
FC/PC60C
HC60
Coil
FC/PC60C
FC/MC/PC60D
UC60D
0.95
0.95
0.95
0.93
0.93
0.93
0.93
0.93
0.98
0.97
0.97
0.94
0.95
0.95
0.95
0.93
0.93
0.93
0.93
0.93
0.98
0.97
0.97
0.94
1.00
1.00
1.00
0.99
0.99
0.99
0.98
0.98
1.01
1.00
0.99
0.98
PV8*C20
PV8*C20
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
PV8*C20
FC/PC60C
FC/MC/PC60D
UC60D
HD60
HD60
FC/MC/PC60D
UC60D
UC60C
UC60D
FC/MC62D
FC/MC62D
FC/MC62D
HC60D
P(C,V)9*C20
P(C,V)9*D20
P(C,V)9*D20
Subject to change without notice. Printed in U.S.A.
Copyright © 2008 by Johnson Controls, Inc. All rights reserved.
350154-YTG-C-0808
Supersedes: 350154-YTG-B-0408
Johnson Controls Unitary Products
5005 York Drive
Norman, OK 73069
|