PLEASE READ BEFORE USE
Thermax World Headquarters
3315 East Texas St
Bossier City, LA 71111
888-764-3700
thermaxaf.com
MAINTENANCE INSTRUCTIONS
CLEANING AND STORAGE
NAME OF PARTS
Fragrance cover
Upper cover
1. Turn the unit OFF and unplug it before cleaning.
2. Use only a water dampened, soft cloth to clean the unit.
3. Never use solvents or other chemicals.
4. Store the unit in a cool, dry place when it is not in use.
REPLACING THE FILTERS
1. Remove and replace the HEPA filter, activated carbon filter at least every
6 months, and photo-catalyst filter at least every 12 months.
2. The life of the filters is affected by the amount of use and the
concentration of pollutants in the air.
Outlet On/Off H/L
Inlet
AIR CLEANING PROCEDURE
3. When replacing filters, please follow these instructions:
DIRTY
PURIFIED
AIR
AIR
IN
OUT
Loosen the screw
Open the upper cover
Replace the filters
ADDING THE THERMAX FRAGRANCE OILS (OPTIONAL)
④ ②③②
①
(See back of manual for list of other fragrances and re-order info)
1. Refill / Replace the fragrance pad at least every 45 days.
2. Keep the fragrance pad away from children. NOT TO BE EATEN!
3. Please replace the fragrance as shown in following instructions:
Our unique two-fan system uses the fan on the right side to draw air
in from the room, to purify it as described below:
① HEPA Filter removes particles and contamination.
② Photo - Catalyst Filters work with UV Light to break down and destroy
poisonous fume,VOCs,odors,germs,viruses,bacteria,mildew and fungus.
③ Ultraviolet Light
④ Activated Carbon Filter eliminates unpleasant smell.
Finally, the fan on the left side draws the purified air through the ionizing
area and releases pure, ionized air back into the room.
Press the fragrance cover in
and let it pop out again.
Turn the container over
and slide the cover off.
-5-
Add the Essential oil(s)
of your choice to cotton pad.
-2-
OPERATING INSTRUCTIONS
MAIN FEATURES
Combining the advanced technologies of UV light, multi-layer filters,
and negative ion generation…
ON/OFF
H/L
The Thermax model 8510 reduces the air pollution caused by dust, germs,
bacteria, harmful gases, smoke, odors and vehicle exhaust.
Detailed features
IMPORTANT…
DO NOT OPERATE THE UNIT WITHOUT FILTERS AND UV LIGHT
INSTALLED.
1. The HEPA filter: Traps particles as small as 0.3 microns
( allergens, pollen, dust, smoke, pet dander, etc. )
1. One HEPA TYPE filter, one activated carbon filter, Ultraviolet light and
two photo - catalyst filters are pre-installed. There is nothing further to
install in order to start using the unit.
2. Activated carbon filter: Absorbs smoke and odors.
3. UV light and photo-catalyst filter:
--Breaks down poisonous fumes and VOC’s, i.e. formaldehyde, ammonia.
--Kills germs, viruses and bacteria.
2. To use the built in Aromatherapy function, press the cover in to release
the tray, then remove the plastic cover and add the essential oil of your
choice to the cotton pad. Replace the cover and tray into the unit.
To remove or replace the tray simply, “push in”.
--Kills mold, mildew and fungus spores.
--Eliminates the smell of smoke, and other annoying odors.
4. Negative Ions: Are added to the air, after filtration, to help freshen and
“revitalize”. Negative Ions have been said to improve people’s pulmonary
and heart muscle functions. (This is not a proven study though.)
5. Aromatherapy: Add the essential oil of your choice to aromatize the air.
3. Plug the adapter into the proper power source.
4. Press the ON/OFF button to turn the unit ON and the LED on the left
side will glow Red. Press the ON/OFF button again to turn the unit
OFF and the LED light will also turn OFF. The Ionizer and UV light will
always be on when the power for the unit is turned ON.
5. Press the H/L button to adjust the airflow to HIGH = (Red indicator)
or LOW = ( Green indicator )
(See back of manual for list of other fragrances and re-order info)
TECHNICAL SPECIFICATIONS
1. Rated Voltage: 12 Volts DC
2. Rated Power: 8 Watts (on high setting)
3. Negative Ion: Greater than 3,000,000 ions per cubic centimeter
PLEASE NOTE:
4. Airflow:
30 Cubic Meters / hour - 18 Cubic feet / minute (High)
15 Cubic Meters / hour - 9 Cubic feet / minute (Low)
Wavelength: 365 nanometers
Lamp life: Approx. 20,000 hours
3.3 Pounds (with adapter)/1.5kgs
ꢀ
ꢀ
ꢀ
For quick air cleaning, set the speed control to HIGH setting. After
about 30 minutes, set the speed control to the LOW speed setting.
To maintain fresh air at all times, set the speed control to LOW speed
setting. The unit uses very little electricity.
5. UV Light:
6. Weight:
7. Dimensions:
8.27’’ W x 4.72’’D x 2.95’’H or (210 x 120 x 75 mm )
For evening quiet use, set the speed control to the LOW speed setting.
8. Coverage Area: Approx. 170 Sq. Feet (room size = 12’ x 15’)
15 sq. Meter (room size= 3m x 5m)
-3-