Smc Networks Mht2 User Manual

Angular Style Air Gripper  
Toggle Type  
Series MHT2  
MHZ  
MHF  
MHL  
MHR  
MHK  
MHS  
MHC  
MHT  
MHY  
MHW  
MRHQ  
Misc.  
D-  
20-  
12-9-1  
Angular Style Air Gripper  
Toggle Type  
Series MHT2  
Effective Gripping Force  
• Workpiece gripping point should be within the  
range indicated in the graph.  
L = 100 mm  
MHT2-32D  
MHT2-40D  
MHT2-50D  
MHT2-63D  
MHZ  
MHF  
MHL  
MHR  
MHK  
MHS  
MHC  
MHT  
MHY  
MHW  
MRHQ  
Misc.  
D-  
Pressure 0.6 MPa  
0.4 MPa  
0.2 MPa  
Opening/Closing angle (Both sides)  
L = 120 mm  
L = 150 mm  
L = 180 mm  
• Indication of effective gripping force  
The effective gripping force shown in the  
graphs to the right is expressed as F, which is  
the thrust of one finger, when both fingers and  
attachments are in full contact with the work-  
piece as shown in the figure below.  
Pressure 0.6 MPa  
0.4 MPa  
0.2 MPa  
Opening/Closing angle (Both sides)  
20-  
Pressure 0.6 MPa  
0.4 MPa  
0.2 MPa  
Precautions  
Opening/Closing angle (Both sides)  
Be sure to read before handling.  
Refer to pages 12-15-3 to 12-15-4 for  
Safety Instructions and Common  
Precautions on the product  
mentioned in this catalog, and refer  
to pages 12-1-4 to 12-1-6 for  
Precautions on every series.  
Warning  
Maintenance  
If a workpiece is to be gripped by using  
the toggle, make sure to periodically  
check that the workpiece has not shifted  
during the acceleration of the movement.  
If the workpiece is not gripped in a stable  
manner, it could shift or drop and create a  
dangerous situation.  
Pressure 0.6 MPa  
0.4 MPa  
0.2 MPa  
Opening/Closing angle (Both sides)  
If the workpiece is not gripped in a stable  
manner, use shims on the attachment to  
adjust the gripped.  
To verify the gripping condition or to make  
any adjustments, make sure to do so in  
an area where the air gripper or the  
workpiece will not fall.  
12-9-3  
Series MHT2  
Dimensions  
8-M6 x 1 mounting thread  
Thread depth 10 (Both sides)  
MHT2-32D  
4-M6 x 1 thread depth 10  
Mounting thread  
Finger closing port  
Rc 1/8  
Finger opening port  
Rc 1/8  
4-M6 x 1 thread depth 15  
Mounting thread  
4-M6 x 1 bottom hole dia. 5.1  
Thread for mounting attachment  
MHT2-40D  
8-M8 x 1.25 mounting thread  
Thread depth 10 (Both sides)  
4-M6 x 1 thread depth 10  
Mounting thread  
Finger closing port  
Rc 1/8  
Finger opening port  
Rc 1/8  
4-M8 x 1.25 thread depth 12  
Mounting thread  
4-M8 x 1.25 bottom hole dia. 6.8  
Thread for mounting attachment  
12-9-4  
Angular Style Air Gripper  
Toggle Type  
Series MHT2  
Dimensions  
MHT2-50D  
8-M10 x 1.5 mounting thread  
Thread depth 12 (Both sides)  
4-M8 x 1.25 thread depth 14  
Mounting thread  
MHZ  
MHF  
MHL  
MHR  
MHK  
MHS  
MHC  
MHT  
MHY  
MHW  
MRHQ  
Misc.  
D-  
Finger closing port  
Rc 1/4  
Finger opening port  
Rc 1/4  
4-M10 x 5 bottom hole dia. 8.6  
Thread for mounting attachment  
4-M10 x 1.5 thread depth 12  
Mounting thread  
MHT2-63D  
8-M12 x 1.75 mounting thread  
Thread depth 17 (Both sides)  
20-  
4-M10 x 1.5 thread depth 18  
Mounting thread  
Finger closing port  
Rc 1/4  
Finger opening port  
Rc 1/4  
4-M12 x 1.75 thread depth 10  
Mounting thread  
4-M12 x 1.75 bottom hole dia. 10.4  
Thread for mounting attachment  
12-9-5  
Series MHT2  
Construction  
Component Parts  
No.  
q
w
e
r
t
y
u
i
o
!
Description  
Material  
Note  
Side plate  
Aluminum alloy  
Carbon steel  
Carbon steel  
Carbon steel  
Stainless steel  
Stainless steel  
Soft steel  
Hard anodized  
Finger  
Black zinc chromated  
Black zinc chromated  
Black zinc chromated  
Lever  
Joint  
Shaft  
Joint pin  
Cylinder plate  
Lever pin  
Bearing  
Cylinder  
Black zinc chromated  
Stainless steel  
Steel lined oil imfilled acetal resin bearing  
Compact cylinder  
Replacement Parts  
Description  
Finger assembly  
Lever assembly  
MHT2-32D  
MH-TA3201  
MH-TA3202  
MHT2-40D  
MH-TA4001  
MH-TA4002  
MHT2-50D  
MH-TA5001  
MH-TA5002  
MHT2-63D  
MH-TA6301  
MH-TA6302  
Main parts  
wo  
e
<ø32, ø40> weryio  
<ø50, ø63> werio  
!
Link parts assembly  
MH-TA3203  
MH-TA4003  
MH-TA5003  
MH-TA6303  
Compact cylinder  
CDQ2A32-15D  
CDQ2A40-15D  
CDQ2A50-20D  
CDQ2A63-20D  
For finger assembly, lever assembly, order 2 pieces per one unit.  
Attachment Design  
Use shims for fine adjustment of the attachment.  
Shim  
12-9-6  
Angular Style Air Gripper  
Toggle Type  
Series MHT2  
Mounting of Auto Switch  
Auto Switch Hysteresis  
Rail mounting type  
MHZ  
MHF  
MHL  
MHR  
MHK  
MHS  
MHC  
MHT  
MHY  
MHW  
MRHQ  
Misc.  
D-  
Hysteresis  
Switch operating position (ON)  
Switch reset position (OFF)  
Hysteresis (Max.) angle  
Model  
MHT2-32D  
MHT2-40D  
MHT2-50D  
MHT2-63D  
3
3
3
3
Direct mounting type  
D-A7, D-A8: Rail mounting type  
.
D-M9V: Direct mounting type are shown above.  
Rail mounting  
Direct mounting  
20-  
D-A7H/A80H  
D-A73C/A80C  
D-F7BAL/F7BAVL  
D-F7/J79  
D-F7V/J79C  
D-F7W/F79F  
D-F7WV  
D-M9  
D-M9V  
D-F9W  
D-F9WV  
D-A9„  
D-A9V  
D-A7/A80  
D-A79W  
D-F9BA  
Bore size  
(mm)  
D-J79W  
A
9
B
6
A
9.5  
B
6.5  
9
A
B
3.5  
6
C
8
D
5
C
12  
D
9
C
11  
D
8
32  
40  
50  
63  
6.5  
10.5  
8.5  
13  
8.5  
11.5  
14.5  
13.5  
11.5  
14  
12  
7.5  
10.5  
13.5  
16  
11.5  
14.5  
17.5  
15  
10.5  
13.5  
16.5  
11  
12  
15  
9
10  
14  
13  
13.5  
11  
12  
12.5  
16.5  
15.5  
Refer to page 12-13-1 for further information on other auto  
switches.  
Type  
Electrical entry (direction)  
Features  
Model  
Grommet (Perpendicular)  
Grommet (In-line)  
Connector (Perpendicular)  
Grommet (In-line)  
D-A80  
D-A80H  
D-A80C  
D-A90  
Without  
indicator light  
Reed switch  
Grommet (Perpendicular)  
D-A90V  
For details, refer to Best Pneumatics Vol. 7/8/9/10, because there are  
other types of normally closed (NC = b contact) solid state switches.  
(D-F9G/F9H)  
12-9-7  
Series MHZ2/MHZJ2/MHK2/MHKL2/MHC2/MHT2  
Auto Switch Installation Example  
and Mounting Position  
Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions.  
1) Detection when Gripping Exterior of Workpiece  
1. Confirmation of fingers in  
reset position  
2. Confirmation of workpiece held  
3. Confirmation of workpiece released  
Detection example  
Position of  
fingers fully  
opened  
Position  
when  
gripping  
workpiece  
Position of  
fingers fully  
closed  
Position to be  
detected  
Switch turned on when fingers return.  
(Light ON)  
Switch turned on when gripping a  
workpiece.  
(Light ON)  
When a workpiece is held (Normal operation):  
Switch to turn OFF (Light not illuminating)  
When a workpiece is not held (Abnormal operation):  
Switch to turn ON (Light illuminating)  
Operation of  
auto switch  
Ȝ
One auto  
switch  
Ȝ
Ȝ
Ȝ
Ȝ
Ȝ
Ȝ
Two auto  
switches  
Ȝ
Ȝ
Step 1)  
Fully open the  
fingers.  
Step 1)  
Position  
fingers for  
gripping a  
workpiece.  
Step 1)  
Fully close the  
fingers.  
How to determine  
auto switch  
installation position  
At no pressure or low  
pressure, connect the  
Step 2) Insert the auto switch into the switch installation groove in the direction shown in the following drawing.  
switch to  
a
power  
supply, and follow the  
directions.  
Step 3) Slide the auto switch in the Step 3) Slide the auto switch in the direction of the arrow until the light illuminates and  
direction of the arrow until the indicator fasten it at a position 0.3 to 0.5 mm in the direction of the arrow beyond the position  
light illuminates.  
where the indicator light illuminates.  
Position where light turns ON  
Step 4) Slide the auto switch further in  
the direction of the arrow until the  
indicator light goes out.  
0.3 to 0.5 mm  
Step 5) Move the auto switch in the  
opposite direction and fasten it at a  
position 0.3 to 0.5 mm beyond the  
position where the indicator light  
illuminates.  
Position to be secured  
Position where light turns ON  
0.3 to 0.5 mm  
Position to be  
secured  
Note 1) It is recommended that gripping of a workpiece be performed close to the center of the finger stroke.  
Note 2) When holding a workpiece close at the end of open/close stroke of fingers, detecting performance of the combinations listed in the above  
table may be limited, depending on the hysteresis of an auto switch, etc.  
12-12-2  
Auto Switch  
Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions.  
2) Detection when Gripping Interior of Workpiece  
1. Confirmation of fingers in reset  
position  
2. Confirmation of workpiece held  
3. Confirmation of workpiece released  
Detection example  
Position of  
fingers  
fully  
Position  
when  
Position of  
fingers fully  
opened  
Position to be  
detected  
MHZ  
MHF  
MHL  
MHR  
MHK  
MHS  
MHC  
MHT  
MHY  
MHW  
MRHQ  
Misc.  
D-  
gripping  
closed  
Switch turned ON when fingers return.  
(Light ON)  
Switch turned ON when gripping a  
workpiece.  
(Light ON)  
When a workpiece is held (Normal operation):  
Switch to turn OFF (Light not illuminating)  
When a workpiece is not held (Abnormal operation):  
Switch to turn ON (Light illuminating)  
Operation of  
auto switch  
Ȝ
One auto  
switch  
Ȝ
Ȝ
Ȝ
Ȝ
Ȝ
Ȝ
Two auto  
switches  
Ȝ
Ȝ
Step 1)  
Fully close the  
fingers.  
Step 1)  
Position  
fingers for  
gripping a  
workpiece.  
Step 1)  
Fully open the  
fingers.  
How to determine  
auto switch  
installation position  
Step 2) Insert the auto switch into the switch installation groove in the direction shown in the following drawing.  
At no pressure or low  
pressure, connect the  
switch to  
a
power  
supply, and follow the  
directions.  
Step 3) Move the auto switch in the  
direction of the arrow and fasten it at a  
position 0.3 to 0.5 mm beyond the  
position where the indicator light  
illuminates.  
Step 3) Slide the auto switch in the direction of the arrow until the indicator light  
illuminates.  
20-  
Position where  
light turns ON  
Step 4) Slide the auto switch further in the direction of the arrow until the indicator  
light goes out.  
0.3 to 0.5 mm  
Position to be  
secured  
Step 5) Move the auto switch in the opposite direction 0.3 to 0.5 mm in the  
direction indicated by the arrow from its location when the indicator light comes on  
again.  
Position where  
light turns ON  
0.3 to 0.5 mm  
Position to be  
secured  
Note 1) It is recommended that gripping of a workpiece be performed close to the center of the finger stroke.  
Note 2) When holding a workpiece close at the end of open/close stroke of fingers, detecting performance of the combinations listed in the above  
table may be limited, depending on the hysteresis of an auto switch, etc.  
12-12-3  
Safety Instructions  
These safety instructions are intended to prevent a hazardous situation and/or  
equipment damage. These instructions indicate the level of potential hazard by labels of  
"Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1)  
JIS B 8370 Note 2) and other safety practices.  
,
Operator error could result in injury or equipment damage.  
Caution :  
Operator error could result in serious injury or loss of life.  
Warning  
:
In extreme conditions, there is a possible result of serious injury or loss of life.  
Danger :  
Note 1) ISO 4414: Pneumatic fluid power--General rules relating to systems.  
Note 2) JIS B 8370: General Rules for Pneumatic Equipment  
Warning  
1. The compatibility of pneumatic equipment is the responsibility of the person  
who designs the pneumatic system or decides its specifications.  
Since the products specified here are used in various operating conditions, their compatibility for the  
specific pneumatic system must be based on specifications or after analysis and/or tests to meet your  
specific requirements. The expected performance and safety assurance will be the responsibility of the  
person who has determined the compatibility of the system. This person should continuously review  
the suitability of all items specified, referring to the latest catalog information with a view to giving due  
consideration to any possibility of equipment failure when configuring a system.  
2. Only trained personnel should operate pneumatically operated machinery  
and equipment.  
Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of  
pneumatic systems should be performed by trained and experienced operators.  
3.Do not service machinery/equipment or attempt to remove components until  
safety is confirmed.  
1. Inspection and maintenance of machinery/equipment should only be performed once measures to  
prevent falling or runaway of the driver objects have been confirmed.  
2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply  
pressure for this equipment and exhaust all residual compressed air in the system.  
3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston  
rod, etc.  
4. Contact SMC if the product is to be used in any of the following conditions:  
1. Conditions and environments beyond the given specifications, or if product is used outdoors.  
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles,  
medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and  
brake circuits in press applications, or safety equipment.  
3. An application which has the possibility of having negative effects on people, property, or animals,  
requiring special safety analysis.  
12-15-3  
Common Precautions  
Be sure to read before handling.  
For detailed precautions on every series, refer to main text.  
4. Use clean air  
Selection  
If the compressed air supply is contaminated with chemicals,  
cynthetic materials, corrosive gas, etc., it may lead to break  
down or malfunction.  
Warning  
1. Confirm the specifications.  
Products represented in this catalog are designed for use in  
compressed air appllications only (including vacuum), unless  
otherwise indicated.  
Operating Environment  
Warning  
Do not use the product outside their design parameters.  
Please contact SMC when using the products in applications  
other than compressed air (including vacuum).  
1. Do not use in environments where the product  
is directly exposed to corrosive gases,  
chemicals, salt water, water or steam.  
Mounting  
2. Do not expose the product to direct sunlight  
for an extended period of time.  
Warning  
3. Do not use in a place subject to heavy  
vibrations and/or shocks.  
4. Do not mount the product in locations where it  
is exposed to radiant heat.  
1. Instruction manual  
Install the products and operate them only after reading the  
instruction manual carefully and understanding its contents.  
Also keep the manual where it can be referred to as  
necessary.  
Maintenance  
2. Securing the space for maintenance  
When installing the products, please allow access for  
maintenance.  
Warning  
1. Maintenance procedures are outlined in the  
operation manual.  
3.Tightening torque  
When installing the products, please follow the listed torque  
specifications.  
Not following proper procedures could cause the product to  
malfunction and could lead to damage to the equipment or  
machine.  
Piping  
2. Maintenance work  
If handled improperly, compressed air can be dangerous.  
Assembly, handling and repair of pneumatic systems should  
be performed by qualified personnel only.  
Caution  
1. Before piping  
Make sure that all debris, cutting oil, dust, etc, are removed  
from the piping.  
3. Drain flushing  
Remove drainage from air filters regularly. (Refer to the  
specifications.)  
2. Wrapping of pipe tape  
When screwing piping or fittings into ports, ensure that chips  
from the pipe threads or sealing material do not get inside the  
piping. Also, when the pipe tape is used, leave 1.5 to 2 thread  
ridges exposed at the end of the threads.  
4. Shut-down before maintenance  
Before attempting any kind of maintenance make sure the  
supply pressure is shut of and all residual air pressure is  
released from the system to be worked on.  
5. Start-up after maintenance and inspection  
Apply operating pressure and power to the equipment and  
check for proper operation and possible air leaks. If operation  
is abnormal, please verify product set-up parameters.  
Air Supply  
Warning  
1. Operating fluid  
6. Do not make any modifications to be product.  
Please consult with SMC when using the product in  
applications other than compressed air (including vacuum).  
Regarding products for general fluid, please ask SMC about  
applicable fluids.  
Do not take the product apart.  
2. Install an air dryer, aftercooler, etc.  
Excessive condensate in a compressed air system may cause  
valves and other pneumatic equipment to malfunction.  
Installation of an air dryer, after cooler etc. is recommended.  
3. Drain flushing  
If condensate in the drain bowl is not emptied on a regular  
basis, the bowl will over flow and allow the condensate to  
enter the compressed air lines.  
If the drain bowl is difficult to check and remove, it is  
recommended that a drain bowl with the auto-drain option be  
installed.  
For compressed air quality, refer to “Air Preparation  
Equipment” catalog.  
12-15-4  
Quality Assurance Information  
(ISO 9001, ISO 14001)  
Reliable quality of products in the global market  
To enable our customers throughout  
the world to use our products with  
even greater confidence, SMC has  
obtained certification for international  
standards “ISO 9001” and “ISO  
14001”, and created a complete  
structure for quality assurance and  
SMC’s quality control system  
Make customers our  
first priority, offering  
them reliable and  
friendly service.  
Create new  
products using the  
latest technology,  
and offer the finest  
products in a  
Produce the highest  
quality with the  
participation of all  
employees.  
timely manner.  
environmental  
controls.  
SMC  
Quality policies  
products pursue to meet its  
customers’ expectations while also  
considering company’s contribution in  
society.  
Market research  
Product planning  
After service  
Sales coordination  
New product evaluation  
Reliability design  
Reliability testing  
New technical  
Quality system  
education  
Training of  
suppliers  
Research  
Education  
Training  
Design  
Development  
Production  
Quality management system  
development  
ISO 9001  
Process control  
Inspection, testing, etc.  
Initial production control  
This is an international standard for quality control  
and quality assurance. SMC has obtained a large  
number of certifications in Japan and overseas,  
providing assurance to our customers throughout  
the world.  
Quality control activities  
Environmental management system  
ISO 14001  
This is an international standard related to  
environmental management systems and  
environmental inspections. While promoting  
environmentally friendly automation technology,  
SMC is also making diligent efforts to preserve  
the environment.  
12-15-5  
SMC Product Conforming to Inter  
SMC products complying with EN/ISO, CSA/UL standards are supporting  
CE Mark  
The CE mark indicates that machines and components meet essential requirements of all the EC Directives  
applied.  
It has been obligatory to apply CE marks indicating conformity with EC Directives when machines and  
components are exported to the member Nations of the EU.  
Once “A manufacturer himself” declares a product to be safe by means of CE marking (declaration of  
conformity by manufacturer), free distribution inside the member Nations of the EU is permissible.  
í CE Mark  
SMC provides CE marking to products to which EMC and Low Voltage Directives have been applied, in  
accordance with CETOP (European hydraulics and pneumatics committee) guide lines.  
í As of February 1998, the following 18 countries will be obliged to conform to CE mark legislation  
Iceland, Ireland, United Kingdom, Italy, Austria, Netherlands, Greece, Liechtenstein, Sweden, Spain, Denmark,  
Germany, Norway, Finland, France, Belgium, Portugal, Luxembourg  
í EC Directives and Pneumatic Components  
• Machinery Directive  
The Machinery Directive contains essential health and safety requirements for machinery, as applied to  
industrial machines e.g. machine tools, injection molding machines and automatic machines. Pneumatic  
equipment is not specified in Machinery Directive. However, the use of SMC products that are certified as  
conforming to EN Standards, allows customers to simplify preparation work of the Technical Construction File  
required for a Declaration of Conformity.  
• Electromagnetic Compatibility (EMC) Directive  
The EMC Directive specifies electromagnetic compatibility. Equipment which may generate electromagnetic  
interference or whose function may be compromised by electromagnetic interference is required to be immune  
to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission).  
• Low Voltage Directive  
This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC  
operating voltage, and require electrical safety measures to be introduced.  
• Simple Pressure Vessels Directive  
This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V)  
exceed 50 bar/L. Such vessels require EC type examination and then CE marking.  
12-15-6  
SMC Product Conforming to International Standards  
national Standards  
you to comply with EC directives and CSA/UL standards.  
Mark of compliance  
for CSA/UL  
Mark of compliance  
for CSA  
í CSA Standards & UL Standards  
UL and CSA standards have been applied in North America (U.S.A. and Canada) symbolizing safety of electric  
products, and are defined to mainly prevent danger from electric shock or fire, resulting from trouble with  
electric products. Both UL and CSA standards are acknowledged in North America as the first class certifying  
body. They have a long experience and ability for issuing product safety certificate. Products approved by CSA  
or UL standards are accepted in most states and governments beyond question.  
Since CSA is a test certifying body as the National Recognized Testing Laboratory (NRTL) within the  
jurisdiction of Occupational Safety and Health Administration (OSHA), SMC was tested for compliance with  
CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards.  
The above CSA NRTL/C logo is described on a product label in order to indicate that the product is approved  
by CSA and UL Standards.  
í TSSA (MCCR) Registration Products  
TSSA is the regulation in Ontario State, Canada. The products that the operating pressure is more than 5 psi  
(0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation.  
Products conforming to CE Standard  
With CE symbol for simple visual recognition  
In this catalog each accredited product series is indicated with a  
CE mark symbol. However, in some cases, every available  
models may not meet CE compliance. Please visit our web site  
for the latest selection of available models with CE mark.  
12-15-7  
SMC’s Global Service Network  
America  
Europe  
U.K. SMC Pneumatics (U.K.) Ltd.  
U.S.A. SMC Corporation of America  
Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN, Backinghamshire, U.K.  
TEL: 01908-563888 FAX: 01908-561185  
3011 North Franklin Road Indianapolis, IN 46226, U.S.A.  
TEL: 317-899-4440 FAX: 317-899-3102  
GERMANY SMC Pneumatik GmbH  
CANADA SMC Pneumatics (Canada) Ltd.  
Boschring 13-15 D-63329 Egelsbach, Germany  
TEL: 06103-4020 FAX: 06103-402139  
6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada  
TEL: 905-812-0400 FAX: 905-812-8686  
ITALY SMC Italia S.p.A.  
Via Garibaldi 62 I-20061 Carugate Milano, Italy  
TEL: 02-9271365 FAX: 02-9271365  
MEXICO SMC Corporation (Mexico), S.A. DE C.V.  
Carr. Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo  
C.P. 36100, Silao, Gto., Mexico  
TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46  
FRANCE SMC Pneumatique S.A.  
1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600  
Marne La Vallee Cedex 3 France  
TEL: 01-64-76-10-00 FAX: 01-64-76-10-10  
CHILE SMC Pneumatics (Chile) S.A.  
Av. La Montaña 1,115 km. 16,5 P. Norte Parque  
Industrial Valle Grande, Lampa Santiago, Chile  
TEL: 02-270-8600 FAX: 02-270-8601  
SWEDEN SMC Pneumatics Sweden AB  
Ekhagsvägen 29-31, S-141 05 Huddinge, Sweden  
TEL: 08-603-07-00 FAX: 08-603-07-10  
ARGENTINA SMC Argentina S.A.  
Teodoro Garcia 3860 (1427) Buenos Aires, Argentina  
TEL: 011-4555-5762 FAX: 011-4555-5762  
SWITZERLAND SMC Pneumatik AG  
Dorfstrasse 7, Postfach 117, CH-8484 Weisslingen, Switzerland  
TEL: 052-396-3131 FAX: 052-396-3191  
BOLIVIA SMC Pneumatics Bolivia S.R.L.  
Avenida Beni Numero 4665  
Santa Cruz de la Sierra-Casilla de Correo 2281, Bolivia  
TEL: 591-3-3428383 FAX: 591-3-3449900  
AUSTRIA SMC Pneumatik GmbH (Austria)  
Girakstrasse 8, A-2100 Korneuburg, Austria  
TEL: 0-2262-6228-0 FAX: 0-2262-62285  
VENEZUELA SMC Neumatica Venezuela S.A.  
Apartado 40152, Avenida Nueva Granada, Edificio Wanlac,  
Local 5, Caracas 1040-A, Venezuela  
SPAIN SMC España, S.A.  
Zuazobidea 14 Pol. Ind. Júndiz 01015 Vitoria, Spain  
TEL: 945-184-100 FAX: 945-184-510  
TEL: 2-632-1310 FAX: 2-632-3871  
PERU (Distributor) IMPECO Automatizacion Industrial S.A.  
AV. Canevaro 752, Lince, Lima, Peru  
TEL: 1-471-6002 FAX: 1-471-0935  
IRELAND SMC Pneumatics (Ireland) Ltd.  
2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin, Ireland  
TEL: 01-403-9000 FAX: 01-466-0385  
URUGUAY (Distributor) BAKO S.A.  
Galicia 1650 esq. Gaboto C.P. 11200, Montevideo, Uruguay  
TEL: 2-401-6603 FAX: 2-409-4306  
NETHERLANDS (Associated company) SMC Pneumatics BV  
De Ruyterkade 120, NL-1011 AB Amsterdam, Netherlands  
TEL: 020-5318888 FAX: 020-5318880  
BRAZIL SMC Pneumaticos Do Brasil Ltda.  
Rua. Dra. Maria Fidelis, nr. 130, Jardim Piraporinha-Diadema-S.P.  
CEP: 09950-350, Brasil  
GREECE (Distributor) S.Parianopoulos S.A.  
7, Konstantinoupoleos Street 11855 Athens, Greece  
TEL: 01-3426076 FAX: 01-3455578  
TEL: 11-4051-1177 FAX: 11-4071-6636  
DENMARK SMC Pneumatik A/S  
Knudsminde 4 B DK-8300  
Odder, Denmark  
COLOMBIA (Distributor) Airmatic Ltda.  
Calle 18 69-05 Apart. Aereo 081045 Santa Fe de Bogotá, Colombia  
TEL: 1-424-9240 FAX: 1-424-9260  
TEL: 70252900 FAX: 70252901  
12-15-20  
SMC’s Global Service Network  
Europe  
Oceania/Asia  
AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd.  
14-18 Hudson Avenue Castle Hill NSW 2154, Australia  
TEL: 02-9354-8222 FAX: 02-9894-5719  
FINLAND SMC Pneumatics Finland OY  
PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland  
TEL: 09-8595-80 FAX: 09-8595-8595  
NORWAY SMC Pneumatics Norway A/S  
Vollsveien 13C, Granfoss Næringspark N-1366 LYSAKER, Norway  
TEL: 67-12-90-20 FAX: 67-12-90-21  
NEW ZEALAND SMC Pneumatics (New Zealand) Ltd.  
8C Sylvia Park Road Mt.Wellington Auckland, New Zealand  
TEL: 09-573-7007 FAX: 09-573-7002  
BELGIUM (Distributor) SMC Pneumatics N.V./S.A.  
Nijverheidsstraat 20 B-2160 Wommelgem Belguim  
TEL: 03-355-1464 FAX: 03-355-1466  
TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd.  
17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN  
TEL: 03-322-3443 FAX: 03-322-3387  
POLAND SMC Industrial Automation Polska Sp.z.o.o.  
ul. Konstruktorska 11A, PL-02-673 Warszawa, Poland  
TEL: 022-548-5085 FAX: 022-548-5087  
HONG KONG SMC Pneumatics (Hong Kong) Ltd.  
29/F, Clifford Centre, 778-784 Cheung, Sha Wan Road, Lai Chi Kok, Kowloon,  
Hong Kong  
TEL: 2744-0121 FAX: 2785-1314  
TURKEY (Distributor) Entek Pnömatik San.ve Tic. Ltd. Sti  
Perpa Tic. Merkezi Kat:11 No.1625 80270 Okmeydani Istanbul, Türkiye  
TEL: 0212-221-1512 FAX: 0212-221-1519  
SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd.  
89 Tuas Avenue 1, Jurong Singapore 639520  
TEL: 6861-0888 FAX: 6861-1889  
RUSSIA SMC Pneumatik LLC.  
36/40 Sredny prospect V.O. St. Petersburg 199004, Russia  
TEL: 812-118-5445 FAX: 812-118-5449  
PHILIPPINES SHOKETSU SMC Corporation  
Unit 201 Common Goal Tower, Madrigal Business Park,  
Ayala Alabang Muntinlupa, Philippines  
CZECH SMC Industrial Automation CZ s.r.o.  
Hudcova 78a, CZ-61200 Brno, Czech Republic  
TEL: 05-4121-8034 FAX: 05-4121-8034  
TEL: 02-8090565 FAX: 02-8090586  
MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd.  
Lot 36 Jalan Delima1/1, Subang Hi-Tech Industrial Park, Batu 3 40000 Shah Alam  
Selangor, Malaysia  
HUNGARY SMC Hungary Ipari Automatizálási kft.  
Budafoki ut 107-113 1117 Budapest  
TEL: 01-371-1343 FAX: 01-371-1344  
TEL: 03-56350590 FAX: 03-56350602  
ROMANIA SMC Romania S.r.l.  
Str. Frunzei, Nr. 29, Sector 2, Bucharest, Romania  
TEL: 01-3205111 FAX: 01-3261489  
SOUTH KOREA SMC Pneumatics Korea Co., Ltd.  
Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu,  
Seoul, 152-050, South Korea  
TEL: 02-3219-0700 FAX: 02-3219-0702  
SLOVAKIA SMC Priemyselná automatizáciá, s.r.o  
Nova 3, SK-83103 Bratislava  
CHINA SMC (China) Co., Ltd.  
TEL: 02-4445-6725 FAX: 02-4445-6028  
7 Wan Yuan St. Beijing Economic & Technological Development Zone 100176, China  
TEL: 010-67882111 FAX: 010-67881837  
SLOVENIA SMC Industrijska Avtomatilca d.o.o.  
Grajski trg 15, SLO- 8360 Zuzemberk, Slovenia  
TEL: 07388-5240 FAX: 07388-5249  
THAILAND SMC Thailand Ltd.  
134/6 Moo 5, Tiwanon Road, Bangkadi, Amphur Muang, Patumthani 12000, Thailand  
TEL: 02-963-7099 FAX: 02-501-2937  
INDIA SMC Pneumatics (India) Pvt. Ltd.  
D-107 to 112, Phase-2, Extension, Noida, Dist. Gautaim Budh Nagar,  
U.P. 201 305, India  
TEL: (0120)-4568730 FAX: 0120-4568933  
SOUTH AFRICA (Distributor) Hyflo Southern Africa (Pty.) Ltd.  
P.O.Box 240 Paardeneiland 7420 South Africa  
TEL: 021-511-7021 FAX: 021-511-4456  
INDONESIA (Distributor) P.T. Riyadi Putera Makmur  
Jalan Hayam Wuruk Komplek Glodok Jaya No. 27-28 Jakarta 11180 Indonesia  
TEL: 021-625 5548 FAX: 021-625 5888  
EGYPT (Distributor) Saadani Trading & Ind. Services  
15 Sebaai Street, Miami 21411 Alexandria, Egypt  
TEL: 3-548-50-34 FAX: 3-548-50-34  
PAKISTAN (Distributor) Jubilee Corporation  
First Floor Mercantile Centre, Newton Road Near Boulton Market P.O. Box 6165  
Karachi 74000 Pakistan  
TEL: 021-243-9070/8449 FAX: 021-241-4589  
ISRAEL (Distributor) Baccara Automation Control  
Kvutzat Geva 18915 Israel  
TEL: 04-653-5960 FAX: 04-653-1445  
SAUDI ARABIA (Distributor) Assaggaff Trading Est.  
P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia  
TEL: 02-6761574 FAX: 02-6708173  
12-15-21  

Melissa 670 200 User Manual
Ohlins 951 6001126 User Manual
Oreck 20061 01revA User Manual
Panasonic Cs E21hkr User Manual
Sanyo 24kls72 User Manual
Soleus Air Air Conditioner Sg Pac 10e2 Ky 101 User Manual
Stellar Industries Si 60 User Manual
Trion M750 User Manual
Xerox 5101 User Manual
York Sunline 2000 48 User Manual