Angular Style Air Gripper
Toggle Type
Series MHT2
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
20-
12-9-1
Angular Style Air Gripper
Toggle Type
Series MHT2
Effective Gripping Force
• Workpiece gripping point should be within the
range indicated in the graph.
L = 100 mm
MHT2-32D
MHT2-40D
MHT2-50D
MHT2-63D
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
Pressure 0.6 MPa
0.4 MPa
0.2 MPa
Opening/Closing angle (Both sides)
L = 120 mm
L = 150 mm
L = 180 mm
• Indication of effective gripping force
The effective gripping force shown in the
graphs to the right is expressed as F, which is
the thrust of one finger, when both fingers and
attachments are in full contact with the work-
piece as shown in the figure below.
Pressure 0.6 MPa
0.4 MPa
0.2 MPa
Opening/Closing angle (Both sides)
20-
Pressure 0.6 MPa
0.4 MPa
0.2 MPa
Precautions
Opening/Closing angle (Both sides)
Be sure to read before handling.
Refer to pages 12-15-3 to 12-15-4 for
Safety Instructions and Common
Precautions on the product
mentioned in this catalog, and refer
to pages 12-1-4 to 12-1-6 for
Precautions on every series.
Warning
Maintenance
If a workpiece is to be gripped by using
the toggle, make sure to periodically
check that the workpiece has not shifted
during the acceleration of the movement.
If the workpiece is not gripped in a stable
manner, it could shift or drop and create a
dangerous situation.
Pressure 0.6 MPa
0.4 MPa
0.2 MPa
Opening/Closing angle (Both sides)
If the workpiece is not gripped in a stable
manner, use shims on the attachment to
adjust the gripped.
To verify the gripping condition or to make
any adjustments, make sure to do so in
an area where the air gripper or the
workpiece will not fall.
12-9-3
Series MHT2
Dimensions
8-M6 x 1 mounting thread
Thread depth 10 (Both sides)
MHT2-32D
4-M6 x 1 thread depth 10
Mounting thread
Finger closing port
Rc 1/8
Finger opening port
Rc 1/8
4-M6 x 1 thread depth 15
Mounting thread
4-M6 x 1 bottom hole dia. 5.1
Thread for mounting attachment
MHT2-40D
8-M8 x 1.25 mounting thread
Thread depth 10 (Both sides)
4-M6 x 1 thread depth 10
Mounting thread
Finger closing port
Rc 1/8
Finger opening port
Rc 1/8
4-M8 x 1.25 thread depth 12
Mounting thread
4-M8 x 1.25 bottom hole dia. 6.8
Thread for mounting attachment
12-9-4
Angular Style Air Gripper
Toggle Type
Series MHT2
Dimensions
MHT2-50D
8-M10 x 1.5 mounting thread
Thread depth 12 (Both sides)
4-M8 x 1.25 thread depth 14
Mounting thread
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
Finger closing port
Rc 1/4
Finger opening port
Rc 1/4
4-M10 x 5 bottom hole dia. 8.6
Thread for mounting attachment
4-M10 x 1.5 thread depth 12
Mounting thread
MHT2-63D
8-M12 x 1.75 mounting thread
Thread depth 17 (Both sides)
20-
4-M10 x 1.5 thread depth 18
Mounting thread
Finger closing port
Rc 1/4
Finger opening port
Rc 1/4
4-M12 x 1.75 thread depth 10
Mounting thread
4-M12 x 1.75 bottom hole dia. 10.4
Thread for mounting attachment
12-9-5
Series MHT2
Construction
Component Parts
No.
q
w
e
r
t
y
u
i
o
!
Description
Material
Note
Side plate
Aluminum alloy
Carbon steel
Carbon steel
Carbon steel
Stainless steel
Stainless steel
Soft steel
Hard anodized
Finger
Black zinc chromated
Black zinc chromated
Black zinc chromated
Lever
Joint
Shaft
Joint pin
Cylinder plate
Lever pin
Bearing
Cylinder
Black zinc chromated
Stainless steel
Steel lined oil imfilled acetal resin bearing
Compact cylinder
Replacement Parts
Description
Finger assembly
Lever assembly
MHT2-32D
MH-TA3201
MH-TA3202
MHT2-40D
MH-TA4001
MH-TA4002
MHT2-50D
MH-TA5001
MH-TA5002
MHT2-63D
MH-TA6301
MH-TA6302
Main parts
wo
e
<ø32, ø40> weryio
<ø50, ø63> werio
!
Link parts assembly
MH-TA3203
MH-TA4003
MH-TA5003
MH-TA6303
Compact cylinder
CDQ2A32-15D
CDQ2A40-15D
CDQ2A50-20D
CDQ2A63-20D
∗ For finger assembly, lever assembly, order 2 pieces per one unit.
Attachment Design
Use shims for fine adjustment of the attachment.
Shim
12-9-6
Angular Style Air Gripper
Toggle Type
Series MHT2
Mounting of Auto Switch
Auto Switch Hysteresis
Rail mounting type
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
Hysteresis
Switch operating position (ON)
Switch reset position (OFF)
Hysteresis (Max.) angle
Model
MHT2-32D
MHT2-40D
MHT2-50D
MHT2-63D
3
3
3
3
Direct mounting type
D-A7, D-A8: Rail mounting type
.
D-M9V: Direct mounting type are shown above.
Rail mounting
Direct mounting
20-
D-A7H/A80H
D-A73C/A80C
D-F7BAL/F7BAVL
D-F7/J79
D-F7V/J79C
D-F7W/F79F
D-F7WV
D-M9
D-M9V
D-F9W
D-F9WV
D-A9
D-A9V
D-A7/A80
D-A79W
D-F9BA
Bore size
(mm)
D-J79W
A
9
B
6
A
9.5
B
6.5
9
A
B
3.5
6
C
8
D
5
C
12
D
9
C
11
D
8
32
40
50
63
6.5
10.5
8.5
13
8.5
11.5
14.5
13.5
11.5
14
12
7.5
10.5
13.5
16
11.5
14.5
17.5
15
10.5
13.5
16.5
11
12
15
9
10
14
13
13.5
11
12
12.5
16.5
15.5
Refer to page 12-13-1 for further information on other auto
switches.
Type
Electrical entry (direction)
Features
Model
Grommet (Perpendicular)
Grommet (In-line)
Connector (Perpendicular)
Grommet (In-line)
D-A80
D-A80H
D-A80C
D-A90
Without
indicator light
Reed switch
Grommet (Perpendicular)
D-A90V
∗ For details, refer to Best Pneumatics Vol. 7/8/9/10, because there are
other types of normally closed (NC = b contact) solid state switches.
(D-F9G/F9H)
12-9-7
Series MHZ2/MHZJ2/MHK2/MHKL2/MHC2/MHT2
Auto Switch Installation Example
and Mounting Position
Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions.
1) Detection when Gripping Exterior of Workpiece
1. Confirmation of fingers in
reset position
2. Confirmation of workpiece held
3. Confirmation of workpiece released
Detection example
Position of
fingers fully
opened
Position
when
gripping
workpiece
Position of
fingers fully
closed
Position to be
detected
Switch turned on when fingers return.
(Light ON)
Switch turned on when gripping a
workpiece.
(Light ON)
When a workpiece is held (Normal operation):
Switch to turn OFF (Light not illuminating)
When a workpiece is not held (Abnormal operation):
Switch to turn ON (Light illuminating)
Operation of
auto switch
Ȝ
One auto
switch
Ȝ
Ȝ
Ȝ
Ȝ
Ȝ
Ȝ
Two auto
switches
Ȝ
Ȝ
Step 1)
Fully open the
fingers.
Step 1)
Position
fingers for
gripping a
workpiece.
Step 1)
Fully close the
fingers.
How to determine
auto switch
installation position
At no pressure or low
pressure, connect the
Step 2) Insert the auto switch into the switch installation groove in the direction shown in the following drawing.
switch to
a
power
supply, and follow the
directions.
Step 3) Slide the auto switch in the Step 3) Slide the auto switch in the direction of the arrow until the light illuminates and
direction of the arrow until the indicator fasten it at a position 0.3 to 0.5 mm in the direction of the arrow beyond the position
light illuminates.
where the indicator light illuminates.
Position where light turns ON
Step 4) Slide the auto switch further in
the direction of the arrow until the
indicator light goes out.
0.3 to 0.5 mm
Step 5) Move the auto switch in the
opposite direction and fasten it at a
position 0.3 to 0.5 mm beyond the
position where the indicator light
illuminates.
Position to be secured
Position where light turns ON
0.3 to 0.5 mm
Position to be
secured
Note 1) It is recommended that gripping of a workpiece be performed close to the center of the finger stroke.
Note 2) When holding a workpiece close at the end of open/close stroke of fingers, detecting performance of the combinations listed in the above
table may be limited, depending on the hysteresis of an auto switch, etc.
12-12-2
Auto Switch
Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions.
2) Detection when Gripping Interior of Workpiece
1. Confirmation of fingers in reset
position
2. Confirmation of workpiece held
3. Confirmation of workpiece released
Detection example
Position of
fingers
fully
Position
when
Position of
fingers fully
opened
Position to be
detected
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
gripping
closed
Switch turned ON when fingers return.
(Light ON)
Switch turned ON when gripping a
workpiece.
(Light ON)
When a workpiece is held (Normal operation):
Switch to turn OFF (Light not illuminating)
When a workpiece is not held (Abnormal operation):
Switch to turn ON (Light illuminating)
Operation of
auto switch
Ȝ
One auto
switch
Ȝ
Ȝ
Ȝ
Ȝ
Ȝ
Ȝ
Two auto
switches
Ȝ
Ȝ
Step 1)
Fully close the
fingers.
Step 1)
Position
fingers for
gripping a
workpiece.
Step 1)
Fully open the
fingers.
How to determine
auto switch
installation position
Step 2) Insert the auto switch into the switch installation groove in the direction shown in the following drawing.
At no pressure or low
pressure, connect the
switch to
a
power
supply, and follow the
directions.
Step 3) Move the auto switch in the
direction of the arrow and fasten it at a
position 0.3 to 0.5 mm beyond the
position where the indicator light
illuminates.
Step 3) Slide the auto switch in the direction of the arrow until the indicator light
illuminates.
20-
Position where
light turns ON
Step 4) Slide the auto switch further in the direction of the arrow until the indicator
light goes out.
0.3 to 0.5 mm
Position to be
secured
Step 5) Move the auto switch in the opposite direction 0.3 to 0.5 mm in the
direction indicated by the arrow from its location when the indicator light comes on
again.
Position where
light turns ON
0.3 to 0.5 mm
Position to be
secured
Note 1) It is recommended that gripping of a workpiece be performed close to the center of the finger stroke.
Note 2) When holding a workpiece close at the end of open/close stroke of fingers, detecting performance of the combinations listed in the above
table may be limited, depending on the hysteresis of an auto switch, etc.
12-12-3
Safety Instructions
These safety instructions are intended to prevent a hazardous situation and/or
equipment damage. These instructions indicate the level of potential hazard by labels of
"Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1)
JIS B 8370 Note 2) and other safety practices.
,
Operator error could result in injury or equipment damage.
Caution :
Operator error could result in serious injury or loss of life.
Warning
:
In extreme conditions, there is a possible result of serious injury or loss of life.
Danger :
Note 1) ISO 4414: Pneumatic fluid power--General rules relating to systems.
Note 2) JIS B 8370: General Rules for Pneumatic Equipment
Warning
1. The compatibility of pneumatic equipment is the responsibility of the person
who designs the pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility for the
specific pneumatic system must be based on specifications or after analysis and/or tests to meet your
specific requirements. The expected performance and safety assurance will be the responsibility of the
person who has determined the compatibility of the system. This person should continuously review
the suitability of all items specified, referring to the latest catalog information with a view to giving due
consideration to any possibility of equipment failure when configuring a system.
2. Only trained personnel should operate pneumatically operated machinery
and equipment.
Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of
pneumatic systems should be performed by trained and experienced operators.
3.Do not service machinery/equipment or attempt to remove components until
safety is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed once measures to
prevent falling or runaway of the driver objects have been confirmed.
2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply
pressure for this equipment and exhaust all residual compressed air in the system.
3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston
rod, etc.
4. Contact SMC if the product is to be used in any of the following conditions:
1. Conditions and environments beyond the given specifications, or if product is used outdoors.
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles,
medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and
brake circuits in press applications, or safety equipment.
3. An application which has the possibility of having negative effects on people, property, or animals,
requiring special safety analysis.
12-15-3
Common Precautions
Be sure to read before handling.
For detailed precautions on every series, refer to main text.
4. Use clean air
Selection
If the compressed air supply is contaminated with chemicals,
cynthetic materials, corrosive gas, etc., it may lead to break
down or malfunction.
Warning
1. Confirm the specifications.
Products represented in this catalog are designed for use in
compressed air appllications only (including vacuum), unless
otherwise indicated.
Operating Environment
Warning
Do not use the product outside their design parameters.
Please contact SMC when using the products in applications
other than compressed air (including vacuum).
1. Do not use in environments where the product
is directly exposed to corrosive gases,
chemicals, salt water, water or steam.
Mounting
2. Do not expose the product to direct sunlight
for an extended period of time.
Warning
3. Do not use in a place subject to heavy
vibrations and/or shocks.
4. Do not mount the product in locations where it
is exposed to radiant heat.
1. Instruction manual
Install the products and operate them only after reading the
instruction manual carefully and understanding its contents.
Also keep the manual where it can be referred to as
necessary.
Maintenance
2. Securing the space for maintenance
When installing the products, please allow access for
maintenance.
Warning
1. Maintenance procedures are outlined in the
operation manual.
3.Tightening torque
When installing the products, please follow the listed torque
specifications.
Not following proper procedures could cause the product to
malfunction and could lead to damage to the equipment or
machine.
Piping
2. Maintenance work
If handled improperly, compressed air can be dangerous.
Assembly, handling and repair of pneumatic systems should
be performed by qualified personnel only.
Caution
1. Before piping
Make sure that all debris, cutting oil, dust, etc, are removed
from the piping.
3. Drain flushing
Remove drainage from air filters regularly. (Refer to the
specifications.)
2. Wrapping of pipe tape
When screwing piping or fittings into ports, ensure that chips
from the pipe threads or sealing material do not get inside the
piping. Also, when the pipe tape is used, leave 1.5 to 2 thread
ridges exposed at the end of the threads.
4. Shut-down before maintenance
Before attempting any kind of maintenance make sure the
supply pressure is shut of and all residual air pressure is
released from the system to be worked on.
5. Start-up after maintenance and inspection
Apply operating pressure and power to the equipment and
check for proper operation and possible air leaks. If operation
is abnormal, please verify product set-up parameters.
Air Supply
Warning
1. Operating fluid
6. Do not make any modifications to be product.
Please consult with SMC when using the product in
applications other than compressed air (including vacuum).
Regarding products for general fluid, please ask SMC about
applicable fluids.
Do not take the product apart.
2. Install an air dryer, aftercooler, etc.
Excessive condensate in a compressed air system may cause
valves and other pneumatic equipment to malfunction.
Installation of an air dryer, after cooler etc. is recommended.
3. Drain flushing
If condensate in the drain bowl is not emptied on a regular
basis, the bowl will over flow and allow the condensate to
enter the compressed air lines.
If the drain bowl is difficult to check and remove, it is
recommended that a drain bowl with the auto-drain option be
installed.
For compressed air quality, refer to “Air Preparation
Equipment” catalog.
12-15-4
Quality Assurance Information
(ISO 9001, ISO 14001)
Reliable quality of products in the global market
To enable our customers throughout
the world to use our products with
even greater confidence, SMC has
obtained certification for international
standards “ISO 9001” and “ISO
14001”, and created a complete
structure for quality assurance and
SMC’s quality control system
Make customers our
first priority, offering
them reliable and
friendly service.
Create new
products using the
latest technology,
and offer the finest
products in a
Produce the highest
quality with the
participation of all
employees.
timely manner.
environmental
controls.
SMC
Quality policies
products pursue to meet its
customers’ expectations while also
considering company’s contribution in
society.
Market research
Product planning
After service
Sales coordination
New product evaluation
Reliability design
Reliability testing
New technical
Quality system
education
Training of
suppliers
Research
Education
Training
Design
Development
Production
Quality management system
development
ISO 9001
Process control
Inspection, testing, etc.
Initial production control
This is an international standard for quality control
and quality assurance. SMC has obtained a large
number of certifications in Japan and overseas,
providing assurance to our customers throughout
the world.
Quality control activities
Environmental management system
ISO 14001
This is an international standard related to
environmental management systems and
environmental inspections. While promoting
environmentally friendly automation technology,
SMC is also making diligent efforts to preserve
the environment.
12-15-5
SMC Product Conforming to Inter
SMC products complying with EN/ISO, CSA/UL standards are supporting
CE Mark
The CE mark indicates that machines and components meet essential requirements of all the EC Directives
applied.
It has been obligatory to apply CE marks indicating conformity with EC Directives when machines and
components are exported to the member Nations of the EU.
Once “A manufacturer himself” declares a product to be safe by means of CE marking (declaration of
conformity by manufacturer), free distribution inside the member Nations of the EU is permissible.
í CE Mark
SMC provides CE marking to products to which EMC and Low Voltage Directives have been applied, in
accordance with CETOP (European hydraulics and pneumatics committee) guide lines.
í As of February 1998, the following 18 countries will be obliged to conform to CE mark legislation
Iceland, Ireland, United Kingdom, Italy, Austria, Netherlands, Greece, Liechtenstein, Sweden, Spain, Denmark,
Germany, Norway, Finland, France, Belgium, Portugal, Luxembourg
í EC Directives and Pneumatic Components
• Machinery Directive
The Machinery Directive contains essential health and safety requirements for machinery, as applied to
industrial machines e.g. machine tools, injection molding machines and automatic machines. Pneumatic
equipment is not specified in Machinery Directive. However, the use of SMC products that are certified as
conforming to EN Standards, allows customers to simplify preparation work of the Technical Construction File
required for a Declaration of Conformity.
• Electromagnetic Compatibility (EMC) Directive
The EMC Directive specifies electromagnetic compatibility. Equipment which may generate electromagnetic
interference or whose function may be compromised by electromagnetic interference is required to be immune
to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission).
• Low Voltage Directive
This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC
operating voltage, and require electrical safety measures to be introduced.
• Simple Pressure Vessels Directive
This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V)
exceed 50 bar/L. Such vessels require EC type examination and then CE marking.
12-15-6
SMC Product Conforming to International Standards
national Standards
you to comply with EC directives and CSA/UL standards.
Mark of compliance
for CSA/UL
Mark of compliance
for CSA
í CSA Standards & UL Standards
UL and CSA standards have been applied in North America (U.S.A. and Canada) symbolizing safety of electric
products, and are defined to mainly prevent danger from electric shock or fire, resulting from trouble with
electric products. Both UL and CSA standards are acknowledged in North America as the first class certifying
body. They have a long experience and ability for issuing product safety certificate. Products approved by CSA
or UL standards are accepted in most states and governments beyond question.
Since CSA is a test certifying body as the National Recognized Testing Laboratory (NRTL) within the
jurisdiction of Occupational Safety and Health Administration (OSHA), SMC was tested for compliance with
CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards.
The above CSA NRTL/C logo is described on a product label in order to indicate that the product is approved
by CSA and UL Standards.
í TSSA (MCCR) Registration Products
TSSA is the regulation in Ontario State, Canada. The products that the operating pressure is more than 5 psi
(0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation.
Products conforming to CE Standard
With CE symbol for simple visual recognition
In this catalog each accredited product series is indicated with a
CE mark symbol. However, in some cases, every available
models may not meet CE compliance. Please visit our web site
for the latest selection of available models with CE mark.
12-15-7
SMC’s Global Service Network
America
Europe
U.K. SMC Pneumatics (U.K.) Ltd.
U.S.A. SMC Corporation of America
Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN, Backinghamshire, U.K.
TEL: 01908-563888 FAX: 01908-561185
3011 North Franklin Road Indianapolis, IN 46226, U.S.A.
TEL: 317-899-4440 FAX: 317-899-3102
GERMANY SMC Pneumatik GmbH
CANADA SMC Pneumatics (Canada) Ltd.
Boschring 13-15 D-63329 Egelsbach, Germany
TEL: 06103-4020 FAX: 06103-402139
6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada
TEL: 905-812-0400 FAX: 905-812-8686
ITALY SMC Italia S.p.A.
Via Garibaldi 62 I-20061 Carugate Milano, Italy
TEL: 02-9271365 FAX: 02-9271365
MEXICO SMC Corporation (Mexico), S.A. DE C.V.
Carr. Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo
C.P. 36100, Silao, Gto., Mexico
TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46
FRANCE SMC Pneumatique S.A.
1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600
Marne La Vallee Cedex 3 France
TEL: 01-64-76-10-00 FAX: 01-64-76-10-10
CHILE SMC Pneumatics (Chile) S.A.
Av. La Montaña 1,115 km. 16,5 P. Norte Parque
Industrial Valle Grande, Lampa Santiago, Chile
TEL: 02-270-8600 FAX: 02-270-8601
SWEDEN SMC Pneumatics Sweden AB
Ekhagsvägen 29-31, S-141 05 Huddinge, Sweden
TEL: 08-603-07-00 FAX: 08-603-07-10
ARGENTINA SMC Argentina S.A.
Teodoro Garcia 3860 (1427) Buenos Aires, Argentina
TEL: 011-4555-5762 FAX: 011-4555-5762
SWITZERLAND SMC Pneumatik AG
Dorfstrasse 7, Postfach 117, CH-8484 Weisslingen, Switzerland
TEL: 052-396-3131 FAX: 052-396-3191
BOLIVIA SMC Pneumatics Bolivia S.R.L.
Avenida Beni Numero 4665
Santa Cruz de la Sierra-Casilla de Correo 2281, Bolivia
TEL: 591-3-3428383 FAX: 591-3-3449900
AUSTRIA SMC Pneumatik GmbH (Austria)
Girakstrasse 8, A-2100 Korneuburg, Austria
TEL: 0-2262-6228-0 FAX: 0-2262-62285
VENEZUELA SMC Neumatica Venezuela S.A.
Apartado 40152, Avenida Nueva Granada, Edificio Wanlac,
Local 5, Caracas 1040-A, Venezuela
SPAIN SMC España, S.A.
Zuazobidea 14 Pol. Ind. Júndiz 01015 Vitoria, Spain
TEL: 945-184-100 FAX: 945-184-510
TEL: 2-632-1310 FAX: 2-632-3871
PERU (Distributor) IMPECO Automatizacion Industrial S.A.
AV. Canevaro 752, Lince, Lima, Peru
TEL: 1-471-6002 FAX: 1-471-0935
IRELAND SMC Pneumatics (Ireland) Ltd.
2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin, Ireland
TEL: 01-403-9000 FAX: 01-466-0385
URUGUAY (Distributor) BAKO S.A.
Galicia 1650 esq. Gaboto C.P. 11200, Montevideo, Uruguay
TEL: 2-401-6603 FAX: 2-409-4306
NETHERLANDS (Associated company) SMC Pneumatics BV
De Ruyterkade 120, NL-1011 AB Amsterdam, Netherlands
TEL: 020-5318888 FAX: 020-5318880
BRAZIL SMC Pneumaticos Do Brasil Ltda.
Rua. Dra. Maria Fidelis, nr. 130, Jardim Piraporinha-Diadema-S.P.
CEP: 09950-350, Brasil
GREECE (Distributor) S.Parianopoulos S.A.
7, Konstantinoupoleos Street 11855 Athens, Greece
TEL: 01-3426076 FAX: 01-3455578
TEL: 11-4051-1177 FAX: 11-4071-6636
DENMARK SMC Pneumatik A/S
Knudsminde 4 B DK-8300
Odder, Denmark
COLOMBIA (Distributor) Airmatic Ltda.
Calle 18 69-05 Apart. Aereo 081045 Santa Fe de Bogotá, Colombia
TEL: 1-424-9240 FAX: 1-424-9260
TEL: 70252900 FAX: 70252901
12-15-20
SMC’s Global Service Network
Europe
Oceania/Asia
AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd.
14-18 Hudson Avenue Castle Hill NSW 2154, Australia
TEL: 02-9354-8222 FAX: 02-9894-5719
FINLAND SMC Pneumatics Finland OY
PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland
TEL: 09-8595-80 FAX: 09-8595-8595
NORWAY SMC Pneumatics Norway A/S
Vollsveien 13C, Granfoss Næringspark N-1366 LYSAKER, Norway
TEL: 67-12-90-20 FAX: 67-12-90-21
NEW ZEALAND SMC Pneumatics (New Zealand) Ltd.
8C Sylvia Park Road Mt.Wellington Auckland, New Zealand
TEL: 09-573-7007 FAX: 09-573-7002
BELGIUM (Distributor) SMC Pneumatics N.V./S.A.
Nijverheidsstraat 20 B-2160 Wommelgem Belguim
TEL: 03-355-1464 FAX: 03-355-1466
TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd.
17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN
TEL: 03-322-3443 FAX: 03-322-3387
POLAND SMC Industrial Automation Polska Sp.z.o.o.
ul. Konstruktorska 11A, PL-02-673 Warszawa, Poland
TEL: 022-548-5085 FAX: 022-548-5087
HONG KONG SMC Pneumatics (Hong Kong) Ltd.
29/F, Clifford Centre, 778-784 Cheung, Sha Wan Road, Lai Chi Kok, Kowloon,
Hong Kong
TEL: 2744-0121 FAX: 2785-1314
TURKEY (Distributor) Entek Pnömatik San.ve Tic. Ltd. Sti
Perpa Tic. Merkezi Kat:11 No.1625 80270 Okmeydani Istanbul, Türkiye
TEL: 0212-221-1512 FAX: 0212-221-1519
SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd.
89 Tuas Avenue 1, Jurong Singapore 639520
TEL: 6861-0888 FAX: 6861-1889
RUSSIA SMC Pneumatik LLC.
36/40 Sredny prospect V.O. St. Petersburg 199004, Russia
TEL: 812-118-5445 FAX: 812-118-5449
PHILIPPINES SHOKETSU SMC Corporation
Unit 201 Common Goal Tower, Madrigal Business Park,
Ayala Alabang Muntinlupa, Philippines
CZECH SMC Industrial Automation CZ s.r.o.
Hudcova 78a, CZ-61200 Brno, Czech Republic
TEL: 05-4121-8034 FAX: 05-4121-8034
TEL: 02-8090565 FAX: 02-8090586
MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd.
Lot 36 Jalan Delima1/1, Subang Hi-Tech Industrial Park, Batu 3 40000 Shah Alam
Selangor, Malaysia
HUNGARY SMC Hungary Ipari Automatizálási kft.
Budafoki ut 107-113 1117 Budapest
TEL: 01-371-1343 FAX: 01-371-1344
TEL: 03-56350590 FAX: 03-56350602
ROMANIA SMC Romania S.r.l.
Str. Frunzei, Nr. 29, Sector 2, Bucharest, Romania
TEL: 01-3205111 FAX: 01-3261489
SOUTH KOREA SMC Pneumatics Korea Co., Ltd.
Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu,
Seoul, 152-050, South Korea
TEL: 02-3219-0700 FAX: 02-3219-0702
SLOVAKIA SMC Priemyselná automatizáciá, s.r.o
Nova 3, SK-83103 Bratislava
CHINA SMC (China) Co., Ltd.
TEL: 02-4445-6725 FAX: 02-4445-6028
7 Wan Yuan St. Beijing Economic & Technological Development Zone 100176, China
TEL: 010-67882111 FAX: 010-67881837
SLOVENIA SMC Industrijska Avtomatilca d.o.o.
Grajski trg 15, SLO- 8360 Zuzemberk, Slovenia
TEL: 07388-5240 FAX: 07388-5249
THAILAND SMC Thailand Ltd.
134/6 Moo 5, Tiwanon Road, Bangkadi, Amphur Muang, Patumthani 12000, Thailand
TEL: 02-963-7099 FAX: 02-501-2937
INDIA SMC Pneumatics (India) Pvt. Ltd.
D-107 to 112, Phase-2, Extension, Noida, Dist. Gautaim Budh Nagar,
U.P. 201 305, India
TEL: (0120)-4568730 FAX: 0120-4568933
SOUTH AFRICA (Distributor) Hyflo Southern Africa (Pty.) Ltd.
P.O.Box 240 Paardeneiland 7420 South Africa
TEL: 021-511-7021 FAX: 021-511-4456
INDONESIA (Distributor) P.T. Riyadi Putera Makmur
Jalan Hayam Wuruk Komplek Glodok Jaya No. 27-28 Jakarta 11180 Indonesia
TEL: 021-625 5548 FAX: 021-625 5888
EGYPT (Distributor) Saadani Trading & Ind. Services
15 Sebaai Street, Miami 21411 Alexandria, Egypt
TEL: 3-548-50-34 FAX: 3-548-50-34
PAKISTAN (Distributor) Jubilee Corporation
First Floor Mercantile Centre, Newton Road Near Boulton Market P.O. Box 6165
Karachi 74000 Pakistan
TEL: 021-243-9070/8449 FAX: 021-241-4589
ISRAEL (Distributor) Baccara Automation Control
Kvutzat Geva 18915 Israel
TEL: 04-653-5960 FAX: 04-653-1445
SAUDI ARABIA (Distributor) Assaggaff Trading Est.
P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia
TEL: 02-6761574 FAX: 02-6708173
12-15-21
|