Sinclair Smf C12ai User Manual

MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS  
Technical service manual  
R410A Cassette Inverter multi Series  
Indoor Models  
SMF-C09AI  
SMF-C12AI  
SMF-C18AI  
Outdoor Models  
SMF-4E27AI  
1
1. Features:  
1) Fashion design, quality life;  
2) Low operation noise;  
3) High efficiency screw fan;  
4) Equal, fast, wide-angle cooling, more comfortable.  
3
2.Specification  
indoor unit  
Model  
SMF-C09AI  
SMF-C12AI  
SMF-C18AI  
1Ph,220-240V~,50Hz 1Ph,220-240V~,50Hz 1Ph,220-240V~,50Hz  
Power supply  
Capacity  
Ph-V-Hz  
BTU/h  
BTU/h  
Mpa  
9,000  
11,000  
4.2/2.5  
3.7  
12,000  
13,000  
4.2/2.5  
3.7  
18,000  
20,500  
4.2/2.5  
3.7  
Cooling Capacity  
Heating Capacity  
Design Pressure (Hi/Lo)  
Max. Operating Pressure  
Model  
Mpa  
YDK45-4F  
Welling  
80  
YDK45-4F  
Welling  
80  
YDK45-4F  
Welling  
80  
Brand  
Indoor fan motor  
Power Input  
W
1.5uF/450V  
750/660/540  
2
1.5uF/450V  
830/730/680  
2
2.5uF/450V  
930/830/660  
2
Capacitor  
uF  
Speed(hi/mi/lo)  
a.Number of rows  
b.Tube pitch(a)x row pitch(b)  
c.Fin spacing  
r/min  
21x13.37  
1.3  
21x13.37  
1.3  
21x13.37  
1.3  
mm  
mm  
Hydrophilic aluminium Hydrophilic aluminium Hydrophilic aluminium  
d.Fin type (code)  
Indoor coil  
Ф7.94, innergroove  
tube  
Ф7.94, innergroove  
tube  
Ф7.94, innergroove  
tube  
e.Tube outside dia.and type  
mm  
mm  
1185X210X26.7  
1185X210X26.7  
1185X210X26.7  
f.Coil length x height x width  
g.Number of circuits  
5
5
5
600/500/420  
36/33/30  
680/580/500  
36/33/30  
860/760/650  
43/40/38  
Indoor air flow (Hi/Mi/Lo)  
m3/h  
Indoor noise level (Hi/Mi/Lo)  
dB(A)  
φ6.35 (1/4)  
φ9.53 (3/8)  
φ6.35 (1/4)  
φ12.7 (1/2)  
φ6.35 (1/4)  
φ12.7 (1/2)  
Liquid side/ Gas side  
mm(inch)  
Pipe size  
580×254×580  
580×254×580  
580×254×580  
Indoor  
Dimension (W*H*D)  
Packing (W*H*D)  
mm  
mm  
unit(body)  
750x340×750  
750x340×750  
750x340×750  
4
21/28  
650x30x650  
715x115x715  
3/5  
21/28  
650x30x650  
715x115x715  
3/5  
28/36  
650x30x650  
715x115x715  
3/5  
Net/Gross weight(body)  
Dimension (W*H*D)  
Kg  
mm  
mm  
Kg  
Indoor  
unit(panel)  
Packing  
(W*H*D)  
Net/Gross weight(panel)  
m2  
14-21  
18-26  
35-40  
Application area  
Qty per 20/40/40HQ  
Pieces  
5
OUTDOOR UNIT:  
Outdoor Model  
SMF4E27AI  
double  
1Ph,220-240V~,50Hz  
Indoor unit combination  
Power supply  
single  
Treble  
Quadplex  
Ph-V-Hz  
Btu/h  
W
Cooling Capacity range  
7000~18000  
750~1870  
3.1~7.8  
14000~24000  
21000~26000  
2050~2600  
27000  
2650  
11.1  
Rated input power range  
Rated current range  
EER  
1450~2430  
6.1~10.1  
Cooling  
Heating  
A
8.56~10.9  
10.2  
Heating Capacity range  
Rated input power range  
Rated current range  
COP  
Btu/h  
W
9000~18000  
850~1790  
3.5~7.5  
16000~25000  
1470~2520  
6.1~10.5  
21000~27000  
2020~2650  
28000  
2700  
11.3  
A
8.43~11.1  
10.4  
Max. input consumption  
W
A
4500  
25  
Max. current  
Model  
BA160X2CS-20KU  
Rotary inverter  
GD Toshiba  
18000(60HZ)  
169060HZ)  
11.660HZ)  
60  
Type  
Brand  
Capacity  
Btu/h  
W
Input  
Compressor  
Rated current(RLA)  
Locked rotor Amp(LRA)  
Thermal protector  
Capacitor  
A
A
Internal  
uF  
ml  
85UF/250V  
Refrigerant oil  
fan  
Model  
RB68AF/α68TF/T-68  
750 ml  
Outdoor  
motor  
YDK100-6  
Welling  
Brand  
6
Input  
W
uF  
169(HIGH)  
5uF/500VAC  
900(HIGH)  
2
Capacitor  
Speed  
r/min  
a.Number of rows  
b.Tube pitch(a)x row pitch(b)  
c.Fin spacing  
mm  
mm  
25.4×22  
1.5  
Outdoor coil  
d.Fin type (code)  
e.Tube outside dia.and type  
f.Coil length x height x width  
g.Number of circuits  
Hydrophilic aluminium  
φ9.53 innergroove tube  
850×810×44  
2
mm  
mm  
Outdoor air flow  
m3/h  
dB(A)  
mm  
3500  
Outdoor noise level  
57  
Dimension(W*H*D)  
Packing (W*H*D)  
Net/Gross weight  
895X860X330  
1043X915X395  
80/84  
Outdoor unit  
mm  
Kg  
Refrigerant type and charge  
Design pressure(Hi/Lo)  
g
R410A, 2700  
4.2/2.5  
MPa  
mm(inch)  
Liquid side/ Gas side  
6.35(1/4)/9.53(3/8)  
Max. refrigerant pipe length for  
each unit  
Refrigerant  
piping  
m
m
20  
10  
Max. difference in level between  
indoor and outdoor unit  
Connection wiring  
Plug type  
No  
No  
Thermostat type  
Electronic control  
17~43  
Cooling  
heating  
Operation temp  
-7~21  
7
Qtyper 20/40/40'HQ  
set  
Notes:  
1. Nominal cooling capacities are based on the following conditions:  
Indoor temp: 27°CDB, 19°CWB;  
Outdoor temp: 35°CDB;  
Equivalent ref. Piping: 8m(horizontal)  
Outdoor operating frequency:78Hz  
Indoor combination:7K X4, setting temp.:17,setting fan speed: high speed.  
2. Nominal heating capacities are based on the following conditions:  
Indoor temp: 20°CDB;  
Outdoor temp: 7°CDB, 6°CWB;  
Equivalent ref. Piping: 8m(horizontal)  
Outdoor operating frequency:85Hz  
Indoor combination:7K X4, setting temp.:30,setting fan speed: high speed.  
3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room.  
8
3.Outline and dimension  
Indoor unit(7k/9k/12k/18k):  
Hook  
Panel  
Body  
Nut  
Ceiling  
600  
Chart 4  
401(Hook-location)  
580(Body)  
67  
600(Ceiling hole)  
650(Panel)  
Outdoor unit  
1013  
895  
163  
590  
141  
COMP  
9
4.Indoor unit combination:  
Caution on combination  
The one-drive-four outdoor unit SMF-4E27AI nominal cooling capacity is 8kw(under  
condition of ambient temp. 35db/24wb, indoor temp. 27db/19wb). According to  
refrigeration design criterion, total indoor unit capacity should be equal to outdoor capacity,  
otherwise, we can not guarantee best performance and safe operation. Although, we made  
special design on refrigeration system regarding customers requirements. Based on this,  
when indoor total capacity exceed outdoor capacity, the machine can still run. Under this  
condition, the single indoor unit capacity will attenuate. That means you can not gain the  
nominal capacity, but smaller than it. We are out of responsibility if customers dont follow the  
notice below:  
1. You can connect two, three or four indoor units according to your need;  
2. The total indoor unit nominal capacity should not exceed 11.3kw(42% more than nominal  
capacity);  
3. There should be no more than one 18k (either cassette or duct) indoor unit when four  
indoor units are connected, and other indoor unit should be all 7k;  
4. When three or four indoor units are connected, there should be no more than one cassette.  
If the cassette is present, the other duct should be all 7K  
5. There is no limit to two indoor units combination.  
6. When heating, capacity attenuate sharply if indoor unit capacity exceed too much.  
10  
5. Capacity table  
SMF-4E27AI (7k+7k+7k+7k)  
COOLING  
Indoor  
OUTDOOR TEMPERATURE DRY  
21ºC  
25ºC  
30ºC  
35ºC  
40ºC  
45ºC  
Conditions  
Total capacity kW  
Sensitive capacity kW  
Input kW.  
7.63  
6.11  
1.95  
8.36  
6.69  
2.06  
9.09  
7.27  
2.17  
10.45  
8.36  
2.50  
7.30  
5.84  
2.23  
7.99  
6.40  
2.36  
8.69  
6.95  
2.48  
9.99  
7.99  
2.85  
7.03  
5.63  
2.51  
7.70  
6.16  
2.65  
8.37  
6.70  
2.79  
9.63  
7.70  
3.21  
6.64  
5.31  
2.79  
7.27  
5.81  
2.95  
7.90  
6.32  
3.10  
9.09  
6.37  
5.10  
3.07  
6.98  
5.58  
3.24  
7.58  
6.07  
3.41  
8.72  
6.98  
3.92  
6.17  
4.94  
3.35  
6.76  
5.41  
3.53  
7.35  
5.88  
3.72  
8.45  
6.76  
4.28  
21ºC D  
15ºC W  
Total capacity kW  
Sensitive capacity kW  
Input kW.  
24ºC D  
17ºC W  
Total capacity kW  
Sensitive capacity kW  
Input kW.  
27ºC D  
19ºC W  
Total capacity kW  
Sensitive capacity kW  
Input kW.  
32ºC D  
7.27  
3.57  
23ºC W  
HEATING  
OUTDOOR CONDITIONS  
4ºC D 0ºC D -5ºC D -7ºC D -15ºC D  
3ºC W -1ºC W -6ºC W -8ºC W -16ºC W  
Indoor  
24ºC D 12ºC D 7ºC D  
Conditions  
18ºC W 11ºC W 6ºC W  
Capacity  
kW  
14.66  
5.52  
11.73  
4.42  
11.02  
4.15  
10.20  
3.84  
9.38  
3.53  
8.16  
9.78  
3.68  
9.18  
3.46  
8.50  
3.20  
7.82  
2.94  
6.80  
8.80  
3.50  
8.26  
3.28  
7.65  
3.04  
7.04  
2.80  
6.12  
8.31  
3.31  
7.80  
3.11  
7.23  
2.88  
6.65  
2.65  
5.78  
7.33  
3.13  
6.89  
2.94  
6.38  
2.72  
5.87  
2.50  
5.10  
6.84  
2.94  
6.43  
2.76  
5.95  
2.56  
5.47  
2.36  
4.76  
6.35  
2.58  
5.97  
2.42  
5.53  
2.24  
5.08  
2.06  
4.42  
15ºC  
18ºC  
20ºC  
22ºC  
27ºC  
Input kW.  
Capacity  
kW  
13.77  
5.18  
Input kW.  
Capacity  
kW  
12.75  
4.80  
Input kW.  
Capacity  
kW  
11.73  
4.42  
Input kW.  
Capacity  
kW  
10.20  
Input kW.  
3.84  
3.07  
2.56  
2.43  
2.30  
2.18  
2.05  
1.79  
11  
6. WIRING DIAGRAM  
Indoor unit:  
12  
Outdoor unit (SMF-4E27AI)  
13  
7. Electric control functions:  
7.1 Protection  
1. 3 minutes delay at restart for compressor.  
2. Temperature protection of compressor top, compressor stops when the temp. of top of  
compressor is more than 120, compressor runs when the temp. of top of compressor is less  
than 105.  
3. When AC voltage ³ 270V for 30 seconds, Outdoor Unit stops operation and alarms.  
When AC voltage £ 260V for 30 seconds, Outdoor Unit resumes operation.  
4. Inverter module protection, Inverter module Protection itself has a protection function  
against current, voltage and temperature.  
5. Sensor protection at open circuit and breaking disconnection.  
6. Fan Speed is out of control. When Indoor Fan Speed is too high(higher than High  
Fan+300RPM)or too low(lower than 400RPM), the unit stops and LED displays failure  
information and cant return to normal operation automatically.  
7. Cross Zero signal error warning. If there is no Cross Zero signals in 4 minutes, the unit  
stops and LED displays failure information and cant return to normal operation automatically.  
8. Current protection: When the current is more than 25A, the compressor stops.  
9. Outdoor condenser high temperature protection: Under cooling mode, if T3>65for 3  
minutes, the compressor will stop. When T3<52, the protection is not valid.  
10. Outdoor low temperature protection: If the outdoor temperature is lower than -15for  
1hour, the compressor and fan motor will stop. If the outdoor temperature is higher than -12℃  
for 10 minutes and the compressor stops operation for 1h, or the outdoor temperature is  
higher than 5for 10 minutes, then restart and enter into the prior operation mode.  
11. Compressor pre-heating function: When the outdoor temperature is lower than 3and  
the compressor stops operation for more than 3 hours, or the outdoor temperature is lower  
than 3and the power is just put on, the compressor enters into pre-heating condition. When  
outdoor temp. is more than 5or user operate it, pre-heating condition will finish.  
7.2 Operating mode  
7.2.1 Cooling mode  
1.Indoor fan keeps running, fan speed can be set in high/mid/low/ Auto:  
2.Auto fan at cooling mode: (T=Indoor Temp.-Setting Temp.)  
Condition  
T<1.5  
1.5<T<4℃  
T>4℃  
Indoor fan speed  
Room temp. up  
Low  
Mid.  
High  
High  
Mid.  
Low  
Room temp. down  
T> 3℃  
1<T<3℃  
T<1℃  
3.Anti-freezing control to indoor evaporator at cooling mode( T: evaporator temp. )  
Evaporator Temp.  
Compressor  
T< 4℃  
Off  
On  
T > 8℃  
14  
7.2.2 Dehumidifying mode  
1.The indoor fan is fixed in low speed  
2. Low room temperature protection:  
When room temperature decreases to below 10, indoor fan stop, when room temperature  
restores to over 12, indoor fan start.  
3. At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the same  
as that of cooling mode.  
7.2.3 Heating mode  
1. Indoor Fan actions at heating mode  
Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but Anti-cold  
wind function prevails.  
Anti-cold wind control function at heating mode  
Condition  
Indoor fan speed  
T= Indoor exchanger  
temp.  
Indoor exchanger temp. T<34℃  
Off  
up  
34<T<37℃  
37<T<44℃  
T> 44℃  
Breeze  
Low speed  
Setting fan speed  
Indoor exchanger temp. T> 38℃  
Setting fan speed  
Low speed  
Breeze  
down  
33<T<38℃  
24<T<33℃  
T<24℃  
Off  
1. Auto wind at heating mode  
Room temp. up  
Condition  
T=Indoor Temp.-Setting Temp.  
T<1.5℃  
Indoor fan speed  
High  
Mid.  
Low  
High  
Mid.  
Low  
1.5<T<2.5℃  
T>2.5℃  
Room temp. down  
T<1.0℃  
1.0<T<2.0℃  
T>2.0℃  
2. Indoor evaporator high-temperature protection at heating mode  
Condition  
T= Indoor exchanger temp.  
T<48℃  
Compressor  
On  
53<T<63℃  
T>63℃  
Decrease frequency of compressor  
Off  
7.2.4 Defrost operation  
1. Defrosting condition:  
The temperature of outdoor heat exchanger remains consecutively lower than -2°c for more  
than 40 minutes,  
2. Ending condition of defrosting  
15  
If one of following conditions is satisfied, end the defrost and turn into heating mode:  
a. The defrost time has reached to 10 minutes.  
b. When the temperature of outdoor heat exchanger rises up to 15°C.  
3. Defrosting Actions:  
a. Compressor runs.  
b. 4 way valve switches off,  
c. Outdoor fan switches off  
d. Indoor fan running according to anti-cold wind function in heating mode.  
4. Automatic operation mode  
The air conditioner automatically selects one of the following operation modes: cooling,  
heating or fan only according to the temp. difference between room temp. (TA) and set  
temp. (TS).  
TATS  
Operation mode  
TATS>2℃  
-1TA-TS+2℃  
TA-TS<-1℃  
Cooling  
Fan-only  
Heating (air-only for cooling only type)  
7.3 Mode conflict  
The indoor units can not work cooling mode and heating at same time.  
Heating mode has a priority.  
7.3.1 Definition  
Cooling mode  
Heating Mode  
Fan  
No  
Yes  
No  
Off  
No  
No  
No  
No  
Cooling mode  
Heating Mode  
Fan  
No  
Yes  
No  
Yes  
No  
Yes  
No  
Off  
No  
No  
No: No mode conflict;  
Yes: Mode conflict  
7.3.2 In case of one Indoor unit working in cooling mode or fan mode, and another indoor  
unit is set to heating mode, the indoor unit working in cooling mode or fan mode will  
change to stand by. The outdoor unit will work in heating mode.  
7.3.3 In case of one Indoor unit working in heating mode, and another indoor unit is set to  
cooling mode or fan mode, the indoor unit setting to cooling mode or fan mode will  
change to stand by.  
7.4 Manual switch  
Mode changes when push this button.  
Cooing modeà Auto modeàUnit offà Cooing mode  
At Cooing mode, after 30 minutes cooling operation whose fan speed is set as low, the  
A/C operates with a setting temp. of 24.  
At auto mode, the A/C operates with a set temp. of 24℃  
7.5 Timer Function  
16  
1. The maximum length of timer is 24 hours and the minimum resolving power is 15 minutes.  
2. Timer on: first turn off the A/C, the A/C will be automatically on at the set time.  
3. Timer off: first turn on the A/C, the A/C will be automatically off at the set time  
4. Timer on/off function( on time is earlier than off time): first turn off the A/C, it will be  
automatically on at set time, and later be off at the set time, then unit turns on at set time.  
5. Timer off/on function( off time is earlier than on time): first turn on the A/C, it will be  
automatically off at set time, and later be on at the set time, then unit turns off at set time.  
7.6 Auto restart function  
In case of a sudden power failure, this function automatically sets the unit to previous settings  
before the power failure when power returns.  
7.7 Cooling capacity test frequency locked.  
When test the cooling capacity, the frequency can be locked at 78Hz by following the below:  
1. Set the indoor temp. to 17and high speed;  
2. Push the outdoor check button for 5 seconds, then its frequency can be fixed at 78Hz.  
After the test is over, turn off the indoor to exit.  
When test the heating capacity, the frequency can be locked at 85Hz by following the below:  
1. Set the indoor temp. to 30and high speed;  
2. Push the outdoor check button for 5 seconds, then its frequency can be fixed at 78Hz.  
After the test is over, turn off the indoor to exit.  
7.8 Indoor unit indicator display function:  
Operation Timer De-frost Alarm State  
X
X
X
X
X
X
Indoor room temp. sensor open or short-circuit  
Indoor pipe temp. sensor open or short-circuit  
Indoor and outdoor communication error  
Water level alarm  
X
X
X
X
X
X
X
X
X
EEPROM error  
X
X
Inverter module protection  
X
X
Outdoor sensor open or short circuit  
Outdoor voltage protection  
X
X
Compressor top temp. protection  
Mode conflict  
X
X
Outdoor current protection  
flash, light, X extinguished.  
17  
7.9 Outdoor unit LED display function:  
1. When stand-by it display number of indoor unit online;  
2. When operation it display frequency of outdoor unit;  
3. When defrost it display df;  
4. When a protection or error occurred, it display as the following table:  
Display  
E0  
Explanation  
EEPROM error  
E1  
No 1 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective  
No 2 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective  
No 3 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective  
Outdoor temp. sensor or connector of temp. sensor is defective  
Compressor voltage protection  
E2  
E3  
E4  
E5  
E6  
No 4 Indoor units pipe temp. sensor or connector of pipe temp. sensor is defective  
Indoor and outdoor communication error  
E7  
P0  
Compressor top protection against temperature  
High pressure protection  
P1  
P2  
Low pressure protection  
P3  
Compressor current protection  
P4  
Inverter module protection  
P5  
Outdoor low temp. protection  
P6  
Condenser high-temperature protection  
7.10 Check function:  
There is a check button on outdoor pcb. When push this button, the outdoor LED can display  
in sequence:  
Capacity demandRunning mode revised capacity fan state No.1 evaporator pipe  
temp. No.2 evaporator pipe temp.No.3 evaporator pipe temp.No.4 evaporator pipe  
temp.outdoor pipe temp. Outdoor temp. discharge gas temp.current of outdoor unit  
No. 1 opening degree of electronic expansion valve No. 2 opening degree of EXV →  
No. 3 opening degree of EXVNo. 4 opening degree of EXVindoor unit numberlast  
protection/error codecapacity demand(cycle)  
Explanation for the some display content:  
1. Running mode:  
Display  
Corresponding mode  
Off  
Cooling mode  
Heating mode  
0
1
2
18  
2. Fan state:  
Display  
Corresponding mode  
0
1
2
Off  
Low fan  
High fan  
3. Opening degree of EXV:  
Opening degree equals the display data times 8;  
4. Number of indoor unit  
The indoor unit that can communicate with outdoor unit normally.  
7.11 Outdoor fan speed control  
There is one fan with two-speed, the fan speed is controlled according ambient temp. After  
the compressor stop, 30 seconds later the fan stop.  
When cooling:  
> 27  
<27  
>25  
<25  
High speed  
Low speed  
High speed  
Low speed  
Ambient temp.rise  
Ambient  
temp.decline  
When heating:  
Ambient temp.rise  
> 14  
<14  
>12  
<12  
Low speed  
High speed  
Low speed  
High speed  
Ambient  
temp.decline  
7.12 Oil return function  
If operation frequency is lower than 54Hz in 2 hours consecutively, it will be increased to 62Hz  
for 3 minutes. Then it recovers to the former operation frequency.  
19  
12  
13  
Pipe Temperature Sensor  
Evaporator Ass'y  
Fixing clamp, evaaporater  
Deseparating board, left  
Inlet pipe, eva  
Ass'y  
1
1
1
1
1
1
1
1
1
1
1
4
1
2
1
1
1
2
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
50118121032  
50118121011  
50112111011  
50112111012  
50118121009  
50118121002  
50112111014  
50112111015  
50236113805  
50112111017  
50112111018  
50112111019  
50112111020  
50118121036  
50112111021  
50112111022  
50112111023  
50112111024  
50112111025  
50112111026  
50118121041  
50118121042  
50112111027  
50112111028  
50112111029  
50112111030  
50112111031  
50112111032  
50112111033  
50112111032  
50224121049  
50112111039  
10324121004  
50218131002  
50118121053  
50118121020  
10718121808  
11318111004  
10112121815  
50118121016  
50118121022  
2244050004  
2154209004  
2124200413  
2124200404  
2164209006  
2165239000  
2124200406  
2110011001  
2240041405  
2124200405  
2124200401  
2124200402  
2124200411  
2274200401  
2114209078  
2114200444  
2124200421  
2114200446  
2114200443  
2114200441  
2114200420  
2334209008  
2114200447  
2114200445  
2240028001  
2114208051  
8104200409  
8104200402  
8104200403  
8104200402  
2335509100  
2124200407  
2334209040  
2124200423  
2274200402  
2135239000  
2230090015  
2230080071  
2240119047  
2114090018  
2114090005  
14  
15  
16  
17  
Outlet pipe, eva  
Wire crossing board  
Fan  
18  
19  
20  
Fan Motor  
21  
Fan Motor Underlay  
Base Pan Ass'y  
Fixing board, water pan  
Sealing board, pipe out  
Rubber, wire crossing  
Panel Ass'y  
22  
23  
24  
25  
26  
26.1  
26.2  
26.3  
26.4  
26.5  
26.6  
26.7  
26.8  
26.9  
Air inlet grille  
Switch cover, air inlet grille  
Switch, air inlet grille  
Filter  
Control box  
LED holder  
Control board  
Cover, control box  
Fan guide  
26.10 Swing motor  
26.11 Panel  
26.12 Install cover, swing motor  
26.13 Install cover I  
26.14 Install cover II  
26.15 Install cover I  
27  
Remoter  
28  
Control Box Cover  
E-control Assy  
Control Box  
29  
29.1  
29.2  
29.3  
29.4  
29.5  
29.6  
29.7  
29.8  
Rubber, wire crossing  
PCB Ass'y  
Transformer  
Relay  
Capacity  
Base, wire fixing  
Cover, wire fixing  
21  
11  
12  
Drain Pump Holder  
Pipe Temperature Sensor  
Evaporator Ass'y  
Fixing clamp, evaaporater  
Deseparating board, left  
Inlet pipe, eva  
1
1
1
1
1
1
1
1
1
1
1
1
4
1
2
1
1
1
2
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
50112111010  
50118121032  
50118121011  
50112111011  
50112111012  
50118121009  
50118121002  
50112111014  
50112111015  
50236113805  
50112111017  
50112111018  
50112111019  
50112111020  
50118121036  
50112111021  
50112111022  
50112111023  
50112111024  
50112111025  
50112111026  
50118121041  
50118121042  
50112111027  
50112111028  
50112111029  
50112111030  
50112111031  
50112111032  
50112111033  
50112111032  
50224121049  
50112111039  
10324121004  
50218131002  
50118121053  
50118121020  
10718121808  
11318111004  
10112121815  
50118121016  
50118121022  
2124200409  
2244050004  
2154209004  
2124200413  
2124200404  
2164209006  
2164209109  
2124200406  
2110011001  
2240041405  
2124200405  
2124200401  
2124200402  
2124200411  
2274200401  
2114209078  
2114200444  
2124200421  
2114200446  
2114200443  
2114200441  
2114200420  
2334209008  
2114200447  
2114200445  
2240028001  
2114208051  
8104200409  
8104200402  
8104200403  
8104200402  
2335509100  
2124200407  
2334209040  
2124200423  
2274200402  
2135239000  
2230090015  
2230080071  
2240119047  
2114090018  
2114090005  
Ass'y  
13  
14  
15  
16  
17  
Outlet pipe, eva  
Wire crossing board  
Fan  
18  
19  
20  
Fan Motor  
21  
Fan Motor Underlay  
Base Pan Ass'y  
Fixing board, water pan  
Sealing board, pipe out  
Rubber, wire crossing  
Panel Ass'y  
22  
23  
24  
25  
26  
26.1  
26.2  
26.3  
26.4  
26.5  
26.6  
26.7  
26.8  
26.9  
Air inlet grille  
Switch cover, air inlet grille  
Switch, air inlet grille  
Filter  
Control box  
LED holder  
Control board  
Cover, control box  
Fan guide  
26.10 Swing motor  
26.11 Panel  
26.12 Install cover, swing motor  
26.13 Install cover I  
26.14 Install cover II  
26.15 Install cover I  
27  
Remoter  
28  
Control Box Cover  
E-control Assy  
Control Box  
29  
29.1  
29.2  
29.3  
29.4  
29.5  
29.6  
29.7  
29.8  
Rubber, wire crossing  
PCB Ass'y  
Transformer  
Relay  
Capacity  
Base, wire fixing  
Cover, wire fixing  
23  
15  
16  
Deseparating board, left  
Inlet pipe, eva  
1
1
1
1
1
1
1
1
4
1
2
1
1
1
2
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
50112111012  
50118121009  
50118121002  
50112111014  
50112111015  
50236113805  
50112111017  
50112111018  
50112111019  
50112111020  
50118121036  
50112111021  
50112111022  
50112111023  
50112111024  
50112111025  
50112111026  
50118121041  
50118121042  
50112111027  
50112111028  
50112111029  
50112111030  
50112111031  
50112111032  
50112111033  
50112111032  
50224121049  
50112111039  
10324121004  
50218131002  
50118121053  
50118121020  
10718121808  
11318111004  
13607111808  
50118121016  
50118121022  
2124200404  
2164209006  
2164209109  
2124200406  
2110011001  
2240041405  
2124200405  
2124200401  
2124200402  
2124200411  
2274200401  
2114209078  
2114200444  
2124200421  
2114200446  
2114200443  
2114200441  
2114200420  
2334209008  
2114200447  
2114200445  
2240028001  
2114208051  
8104200409  
8104200402  
8104200403  
8104200402  
2335509100  
2124200407  
2334209040  
2124200423  
2274200402  
2135239000  
2230090015  
2230080071  
2240119019  
2114090018  
2114090005  
17  
Outlet pipe, eva  
Wire crossing board  
Fan  
18  
19  
20  
Fan Motor  
21  
Fan Motor Underlay  
Base Pan Ass'y  
Fixing board, water pan  
Sealing board, pipe out  
Rubber, wire crossing  
Panel Ass'y  
22  
23  
24  
25  
26  
26.1  
26.2  
26.3  
26.4  
26.5  
26.6  
26.7  
26.8  
26.9  
Air inlet grille  
Switch cover, air inlet grille  
Switch, air inlet grille  
Filter  
Control box  
LED holder  
Control board  
Cover, control box  
Fan guide  
26.10 Swing motor  
26.11 Panel  
26.12 Install cover, swing motor  
26.13 Install cover I  
26.14 Install cover II  
26.15 Install cover I  
27  
Remoter  
28  
Control Box Cover  
E-control Assy  
Control Box  
29  
29.1  
29.2  
29.3  
29.4  
29.5  
29.6  
29.7  
29.8  
Rubber, wire crossing  
PCB Ass'y  
Transformer  
Relay  
Capacity  
Base, wire fixing  
Cover, wire fixing  
25  
SMF-4E27AI  
1
2
Clamp for front net  
8
1
1
1
1
1
1
1
1
1
1
2113511801  
2114550002  
2123549027  
2240041722  
2124550017  
2124532935  
2124820000  
2124530063  
2115029006  
2124532936  
2124532912  
Propeller fan  
Holder for fan motor  
fan motor  
3
4
5
Front net  
6
Front clapboard  
Separating board  
Left clapboard  
Little handle  
7
8
9
10  
11  
Cover  
Supporter of back  
26  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
electrical box assembly  
Rear net  
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2335739000  
2114820000  
2154709047  
2114540003  
2165739017  
2165739004  
2115739000  
2165739002  
2165739000  
2125739003  
2124532903  
2125739002  
2113560000  
2165739006  
2125739004  
2165739019  
2125019019  
2230100814  
2230100815  
2140062190  
2125020303  
2125020305  
2125020306  
2230100810  
Condenser Ass'y  
Handle  
D high pressure valve assembly.  
C high pressure valve assembly.  
Big handle  
B high pressure valve assembly.  
A high pressure valve assembly.  
Rear right clapboard  
Cabinet,Front-Right  
installation board for valve  
drain pan  
Capillary pipe Ass'y  
Base Pan  
Ass'y  
four way valve assembly  
inductance box  
reactance  
reactance  
Compressor  
upper cover of inductance  
base of inductance  
surrounding board for inductance  
reactance  
27  

Lexmark 2500 User Manual
Master Lock B35ceh User Manual
Mitsubishi Motors Automobile Parts 4d68 E W User Manual
Pioneer Avh P7550dvd User Manual
Samsung Aw0803b User Manual
Samsung Fx1600 User Manual
Savin 2565 User Manual
Subaru Robin Power Products Automobile Parts 12 2b User Manual
Toshiba Air Conditioner Ceiling Type User Manual
Trion Cv4 User Manual