Point-to-point connection  
Scanner  
Barcode  
reader  
Point-to-point link via communications processors (CPs) is an  
extremely powerful and low-cost alternative to bus systems.  
The advantage of point-to-point links over bus systems is es-  
pecially pronounced when only a few (RS 485) devices are to  
be connected to the SIMATIC S7.  
Process  
controller  
SIMATIC S7  
The CPs can also easily link third-party systems to the  
SIMATIC S7. Thanks to the great flexibility of the CPs, different  
physical transmission media, transmission rates or even cus-  
tomized transmission protocols can be implemented.  
SIMOVERT  
SIMOREG  
Modem  
The CPs have a rugged plastic housing with LEDs for displaying  
operating states and faults.  
For each CP there is a configuring package on CD with elec-  
tronic manual, parameterization screen forms and standard  
function blocks for communication between the CPU and  
the CP.  
PC  
Printer  
Robot  
control  
BDE  
terminal  
3rd party  
PLC  
The configuration data are stored in a system block and  
backed up in the CPU. When modules are replaced, the new  
module is therefore immediately ready for use.  
Point-to-point links for SIMATIC S7-400  
With the S7-400 point-to-point link modules, adaptation to  
the physical transmission media is achieved by plugging in the  
relevant interface submodules, without the need for external  
converters.  
Technical data: Point-to-point connection  
Application  
High-speed response  
Interconnection  
with low data volumes  
Low-cost:  
High-speed:  
With one variable  
interface  
With two variable inter-  
faces  
Transmission rate  
High (115 200 bit/s)  
Low (38 400 bit/s)  
High (115 200 bit/s)  
Loadable protocols  
(Order No. group: 6ES7 340-)  
MODBUS Master (-1AA.),  
MODBUS Slave (-1AB.),  
Data Highway (-1AE.)  
Module  
CP 440  
CP 441-1  
CP 441-2  
Order No. group: 6ES7  
Physical transmission media  
RS 232C (V.24)  
20 mA (TTY)  
440-1.  
441-1.  
441-2.  
All transmission methods, all interface modules,  
plug-in, serial  
RS 422/485 (X.27)  
Integrated transmission protocols  
ASCII  
(up to 32 nodes)  
Printer driver  
3964 (R)  
RK 512  
SIMATIC Modular Controllers  
59  

Lexmark X654 Mfp User Manual
Linak Medline La32 User Manual
Mitsubishi Electronics MrSlim Pch 3gak User Manual
Oki Btx 208 User Manual
Samsung Air Conditioner Aqv36w User Manual
Samsung As24cm1n User Manual
Samsung Us24a1 A2 Rc User Manual
Trane Air Conditioner Tam7a0c36h31sb User Manual
Woodstock Fine Air Filter W1746 User Manual
Xerox Workcentre Pro 90 User Manual