Sharp Fp P60cx User Manual

R
FP-P60CX  
AIR PURIFIER  
OPERATION MANUAL  
PURIFICATEUR D'AIR  
MANUEL D'UTILISATION  
Free standing type  
Type mobile  
Tipo vertical sin soporte  
PURIFICADOR DE AIRE  
MANUAL DE USO  
This product earned the ENERGY STAR by meeting  
strict energy efficiency guidelines set by the US EPA.  
US EPA does not endorse any manufacturer claims of  
healthier indoor air from the use of this product.  
The energy efficiency of this ENERGY STAR qualified  
model is measured based on a ratio between the  
model’s CADR for Dust and the electrical energy it  
consumes, or CADR/Watt.  
Ce produit a le droit de porter la marque ENERGY  
STAR après avoir répondu à des critères stricts en ce  
qui concerne l’efficacité énergétique, tels qu’établis par  
l’agence EPAaux É-U. L’agence EPA aux É-U n’appuie  
aucunement les témoignages publicitaires du fabricant  
indiquant que ce produit rend l’air intérieur des locaux  
plus sain.  
L’efficacité énergétique de ce modèle, qui bénéficie  
de la reconnaissance ENERGY STAR, est mesurée  
par le rapport entre le DAP (débit d’air purifié) du  
modèle et l’énergie électrique qu’il consomme, soit le  
rapport DAP/Watt.  
*Plasmacluster is a trademark of  
Sharp Corporation.  
ENGLISH  
FEATURES  
CONTENTS  
Plasmacluster Ion Control  
FOR CUSTOMER ASSISTANCE(U.S) ..... E-2  
CONSUMER LIMITED WARRANTY(U.S).... E-3  
FOR CUSTOMER ASSISTANCE(CANADA) ... E-4  
LIMITED WARRANTY(CANADA) ......... E-5  
The unit controls the ratio of negative ions and  
positive ions depending on the condition of  
the room.  
• Clean Mode  
Approximately the same numbers of positive  
and negative ions are discharged.  
• Ion Control Mode  
IMPORTANT SAFETY INSTRUCTIONS .. E-6  
• WARNING ..................................................E-6  
• CAUTIONS CONCERNING OPERATION .E-7  
• REMOTE CONTROL LIMITATIONS ..........E-7  
• INSTALLATION GUIDELINES ...................E-7  
• FILTER GUIDELINES ................................E-7  
Plenty of negative ions exist in natural  
surroundings such as waterfalls or forests. In  
this mode, negative ions will be released at  
an increased rate, in order to bring the room  
air close to this natural environment.  
• AUTO Plasmacluster Ion Mode  
The unit will switch between Clean Mode and  
Ion Control Mode automatically depending  
on the amount of impurities in the air detected  
by the odor sensor.  
PART NAMES........................................ E-8  
• MAIN UNIT DISPLAY .................................E-8  
• INCLUDED.................................................E-8  
• BACK .........................................................E-8  
• NIGHT Mode  
The fan speed is automatically switched  
between NORMAL and SILENT, depending  
on the amount of impurities in the air.  
The Plasmacluster Indicator Light and Clean-  
Sign Light will turn off.  
PREPARATION...................................... E-9  
• INSERTING BATTERIES  
IN THE REMOTE CONTROL ....................E-9  
• Filters  
1) Pre-Filter  
• REMOTE CONTROL USE .........................E-9  
• FILTER INSTALLATION .......................... E-10  
It collects large particles.  
2) Washable Active Carbon Filter  
Absorbs odor elements.  
OPERATION ........................................ E-12  
• MAIN UNIT OPERATION ........................ E-12  
• REMOTE CONTROL OPERATION ........ E-14  
Washable to maintain optimum  
deodrization performance.  
3) True HEPA (High Efficiency  
Particulate Air) Filter with Micro-  
bial Control Filter  
CARE AND MAINTENANCE............... E-15  
• MAIN UNIT.............................................. E-15  
• ODOR SENSOR ..................................... E-15  
• FILTER CLEANING................................. E-15  
High-efficiency particle collection including  
pollen and dust.  
• WASHABLE ACTIVE CARBON  
FILTER CARE ......................................... E-16  
• FILTER REPLACEMENT  
Declaration of Conformity  
SHARP AIR PURIFIER FP-P60CX  
This device complies with Part 18 of FCC rules.  
GUIDELINES .......................................... E-17  
Responsible Party:  
SHARP ELECTRONICS CORPORATION  
Sharp Plaza,  
Mahwah, New Jersey 07430-2135  
TEL: 1-800-BE-SHARP  
TROUBLESHOOTING......................... E-18  
SPECIFICATIONS ............................... E-19  
Declaration of Conformity  
SHARP AIR PURIFIER FP-P60CX  
This ISM device complies with Canadian ICES-  
001  
Thank you for purchasing the SHARP Air Puri-  
fier. Please read this manual carefully for the  
correct usage information. Before using this  
product, be sure to read the section: “Important  
Safety Instructions.”  
Responsible Party:  
SHARP ELECTRONICS OF CANADA LTD.  
335 Britannia Road East Mississauga, Ontario  
L4Z 1W9 Canada  
After reading this manual, retain it in a conven-  
ient location for future reference.  
TEL: (905) 568-7140  
E-1  
FOR CUSTOMER ASSISTANCE (the United States)  
To aid in answering questions if you call for service or for reporting loss or theft, please use  
the space below to record the model and serial number located on the back side of the unit.  
MODEL NUMBER  
SERIAL NUMBER  
DATE OF PURCHASE  
Dealer Name  
Address  
City  
State  
Zip  
Telephone  
TO PHONE: Dial 1-800-BE-SHARP (237-4277) for:  
SERVICE (for your nearest Sharp Authorized Servicer)  
PARTS (for your Authorized Parts Distributor)  
ACCESSORIES  
ADDITIONAL CUSTOMER INFORMATION  
TO WRITE: For service problems, warranty information, missing items and other assistance:  
Sharp Electronics Corporation  
Customer Assistance Center  
1300 Naperville Drive  
Romeoville, IL 60446-1091  
Please provide the following information when you write or call: model number, serial  
number, date of purchase, your complete mailing address (including zip code), your daytime  
telephone number (including area code) and description of the problem.  
E-2  
CONSUMER LIMITED WARRANTY  
CONSUMER LIMITED WARRANTY FOR U.S. USERS  
SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the  
“Product”), when shipped in its original container, will be free from defective workmanship and materials, and agrees that  
it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured  
equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below.  
This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below  
nor to any Product the exterior of which has been damaged or defaced, which has been subjected to improper voltage or  
other misuse, abnormal service or handling, or which has been altered or modified in design or construction.  
In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth below and provide  
proof of purchase to the servicer.  
The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law.  
ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE  
LIMITED TO THE PERIOD(S) FROM THE DATE OF PURCHASE SET FORTH BELOW. Some states do not allow  
limitations on how long an implied warranty lasts, so the above limitation may not apply to you.  
Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those  
described herein, or to extend the duration of any warranties beyond the time period described herein on behalf of Sharp.  
The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shall be the sole and  
exclusive remedy available to the purchaser. Correction of defects, in the manner and for the period of time described  
herein, shall constitute complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the  
Product, and shall constitute full satisfaction of all claims, whether based on contract, negligence, strict liability or  
otherwise. In no event shall Sharp be liable, or in any way responsible, for any damages or defects in the Product which  
were caused by repairs or attempted repairs performed by anyone other than an authorized servicer. Nor shall Sharp be  
liable or in any way responsible for any incidental or consequential economic or property damage. Some states do not  
allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you.  
THIS WARRANTY GIVES YOU SPECIFlC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY  
FROM STATE TO STATE.  
FP-P60CX Air Purifier. Be sure to have this information available when  
you need service for your Product.  
Your Product Model Number & Description:  
Warranty Period for this Product:  
One (1) year parts and labor from date of purchase.  
Appearance items of the Product, filters, accessories, or any printed  
materials. Product which has been used for rental and/or commercial  
purposes.  
Additional Item(s) Excluded From Warranty  
Coverage:  
Where to Obtain Service:  
From a Sharp Authorized Servicer located in the United States. To find  
the location of the nearest Sharp Authorized Servicer, call Sharp Toll Free  
at 1-800-BE-SHARP.  
What to Do to Obtain Service:  
Ship prepaid or carry in your Product to a Sharp Authorized Servicer. Be  
sure to have Proof of Purchase available. If you ship the Product, be sure  
it is insured and packaged securely.  
TO OBTAIN SUPPLY, ACCESSORY OR PRODUCT INFORMATION, CALL 1-800-BE-SHARP, OR VISIT OUR WEBSITE AT  
R
SHARP ELECTRONICS CORPORATION  
Sharp Plaza, Mahwah, New Jersey 07430-2135  
E-3  
FOR CUSTOMER ASSISTANCE (Canada)  
To aid in answering questions if you call for service or for reporting loss or theft, please use  
the space below to record the model and serial number located on the back side of the unit.  
MODEL NUMBER  
SERIAL NUMBER  
DATE OF PURCHASE  
Dealer Name  
Address  
City  
Province  
Postal Code  
Telephone  
TO PHONE: Dial 1-905-568-7140 for:  
SERVICE (for your nearest Sharp Authorized Servicer)  
PARTS (for your Authorized Parts Distributor)  
ACCESSORIES  
ADDITIONAL CUSTOMER INFORMATION  
TO WRITE: For service problems, warranty information, missing items and other assistance:  
Sharp Electronics of Canada Ltd.  
Customer Care  
335 Britannia Road East  
Mississauga, Ontario L4Z 1W9  
Please provide the following information when you write or call: model number, serial number,  
date of purchase, your complete mailing address (including Postal Code), your daytime  
telephone number (including area code) and description of the problem.  
E-4  
R
LIMITED WARRANTY (VALID IN CANADA ONLY)  
Consumer Electronics Products  
Congratulations on your purchase!  
Sharp Electronics of Canada Ltd. (hereinafter called “Sharp”) gives the following express warranty to the first consumer  
purchaser for this Sharp brand product, when shipped in its original container and sold or distributed in Canada by  
Sharp or by an Authorized Sharp Dealer:  
Sharp warrants that this product is free, under normal use and maintenance, from any defects in material and  
workmanship. If any such defects should be found in this product within the applicable warranty period, Sharp shall, at  
its option, repair or replace the product as specified herein.  
This warranty shall not apply to:  
(a) Any defects caused or repairs required as a result of abusive operation, negligence, accident, improper  
installation or inappropriate use as outlined in the owner’s manual.  
(b) Any Sharp product tampered with modified, adjusted or repaired by any party other than Sharp, Sharp’s  
Authorized Service Centres or Sharp’s Authorized Servicing Dealers.  
(c) Damage caused or repairs required as a result of the use with items not specified or approved by Sharp, including  
but not limited to head cleaning tapes and chemical cleaning agents.  
(d) Any replacement of accessories, glassware, consumable or peripheral items required through normal use of the  
product including but not limited to earphones, remote controls, AC adapters, batteries, temperature probe, stylus,  
trays, filters, belts, ribbons, cables and paper.  
(e) Any cosmetic damage to the surface or exterior that has been defaced or caused by normal wear and tear.  
(f) Any damage caused by external or environmental conditions, including but not limited to transmission line/power  
line voltage or liquid spillage.  
(g) Any product received without appropriate model, serial number and CSA and/or cUL markings.  
(h) Any products used for rental or commercial purposes.  
(i) Any installation, setup and/or programming charges.  
Should this Sharp product fail to operate during the warranty period, warranty service may be obtained upon delivery  
of the Sharp product together with proof of purchase and a copy of this LIMITED WARRANTY statement to an  
Authorized Sharp Service Centre or an Authorized Sharp Servicing Dealer. In home warranty service may be provided  
at Sharp’s discretion on any Sharp television with the screen size of 27” or larger and on any Sharp Over-the-Range  
Microwave Oven.  
This warranty constitutes the entire express warranty granted by Sharp and no other dealer, service centre or their  
agent or employee is authorized to extend, enlarge or transfer this warranty on behalf of Sharp. To the extent the law  
permits, Sharp disclaims any and all liability for direct or indirect damages or losses or for any incidental, special or  
consequential damages or loss of profits resulting from a defect in material or workmanship relating to the product,  
including damages for the loss of time or use of this Sharp product or the loss of information. The purchaser will be  
responsible for any removal, reinstallation, transportation and insurance costs incurred. Correction of defects, in the  
manner and period of time described herein, constitute complete fulfillment of all obligations and responsibilities of  
Sharp to the purchaser with respect to the product and shall constitute full satisfaction of all claims, whether based on  
contract, negligence, strict liability or otherwise.  
WARRANTY PERIODS:  
Parts & Labour (exceptions noted)  
1 year  
1 year  
1 year  
Audio Products  
Camcorder  
DVD Products  
LCD Projector  
LCD TV  
1 year (lamp 90 days)  
1 year  
Microwave Oven  
Television Products  
VCR Products  
Vacuum Cleaner  
Air Purifier & Air Conditioners  
1 years (magnetron component-4 additional years)  
1 year (picture tube component-1 additional year)  
1 year  
1 year  
1 year (except filters)  
To obtain the name and address of the nearest Authorized Sharp Service Centre or Dealer, please contact:  
SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road, East Mississauga, Ontario L4Z 1W9  
For more information on this Warranty, Sharp Canada Products,  
Accessory Sales, Dealer or Service Locations, please call  
(905)568-7140  
Visit our Web site: www.sharp.ca  
SERVICE  
G
T
R
M
E-5  
IMPORTANT SAFETY INSTRUCTIONS  
When using electrical appliances, basic safety precautions should be followed, including the  
following:  
WARNING - To reduce the risk of electrical shock, fire or injury to persons:  
• Read all instructions before using the air purifier.  
• Use only a 120 volt outlet.  
• The air purifier has a polarized plug (one blade is wider than the other is). This plug will fit in a  
polarized outlet only one way. Initially, if the plug does not fit into the outlet, reverse it. If it still does not  
fit, contact a qualified electrician or service person.  
• Do not use the air purifier if the power cord or plug is damaged or the connection to the wall  
outlet is loose.  
Periodically remove dust from the power plug.  
• Do not insert fingers or foreign objects into the intake or air outlet.  
• When removing the power plug, always hold the plug and never pull the cord.  
Electrical shock and/or fire from short circuit may occur as a result.  
• Do not remove the power plug when your hands are wet.  
• Do not use this air purifier near gas appliances or fireplaces.  
• Remove the power plug from the wall outlet before cleaning the unit and when not using the  
unit.  
Electrical shock from bad insulation and/or fire from short circuit may occur as a result.  
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent,  
Sharp authorized Service Center or similarly qualified person in order to avoid a hazard.  
Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,  
sparks from lit cigarettes, chemical fumes in the air or under a humid condition.  
Be cautions when cleaning the air purifier. Strong corrosive cleansers may damage the exterior.  
Only Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service  
Centre for any problems, adjustments, or repairs.  
The batteries must be removed from the remote control before disposal, and the batteries must be  
disposed of safely.  
NOTE - Radio or TV Interference  
If this air purifier should cause interference to radio or television reception, try to correct the interference  
by one or more of the following measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between the air purifier and radio/TV receiver.  
• Connect the equipment into an outlet on a circuit different from that to which the receiver is con-  
nected.  
• Consult the dealer or an experienced radio/TV technician for help.  
This product fulfils the requirement of the International standard CISPR 11.  
In conformity with this standard, this product is classified as group 2 class B equipment.  
Group 2 means that the equipment intentionally generates radio-frequency in the form of electromagnetic  
radiation for electro-discharge machining equipment.  
Class B equipment means that the equipment suitable to be used in domestic establishments.  
E-6  
CAUTIONS CONCERNING OPERATION  
• Do not block the intake and air outlet.  
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into  
contact with steam.  
• Do not lay the unit down when using.  
• Always hold the handle on the back of the main unit when moving it.  
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in  
bodily injury.  
• Do not operate the unit without the filter.  
• Do not wash and reuse HEPA filter.  
Not only does it not improve filter performance, it may cause electric shock or malfunction.  
• Clean the exterior with a soft cloth only.  
The unit surface may be damaged or cracked.  
In addition, the sensor may malfunction as a result.  
REMOTE CONTROL LIMITATIONS  
DO NOT USE THE REMOTE CONTROL IN THE FOLLOWING LOCATIONS:  
• Any location where there is inverter lighting equipment or electronic spontaneous lighting  
equipment  
The remote control may become inoperative. In this case, move away from such lighting equipment  
or change direction.  
• Location exposed to direct sunlight or fluorescent.  
The unit may not receive signals from the remote control.  
INSTALLATION GUIDELINES  
• During the operation of the product, please place the unit at least 7feet(2m) away from  
equipment which involve electric wave such as televisions, radios or wave clocks, in case  
electrical interference occurs to such equipment.  
• Avoid a location where the sensor is exposed to direct wind.  
The unit may not operate properly.  
• Avoid locations where curtains, etc., come into contact with the intake or air outlet.  
Curtains, etc., may become dirty or a malfunction may occur.  
• Avoid locations where the unit is exposed to condensation, due to drastic temperature changes.  
(Use under appropriate conditions between 0 and 35˚C in the room.)  
• Place on a stable surface with sufficient air circulation.  
When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly.  
• Do not install when there is generation of lampblack, such as in a kitchen, etc.  
The unit surface may crack or the sensor may malfunction as a result.  
• Leave about 2feet(60cm) of space from the wall.  
The wall behind the air outlet may become dirty as time passes. When using the unit for extended  
period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In  
addition, periodically clean the wall.  
FILTER GUIDELINES  
• Follow the instructions in this manual for correct care and maintenance of the filters.  
E-7  
PART NAMES  
MAIN UNIT DISPLAY  
AUTO Operation Indicator Light  
Remote Control Receiver  
CLEAN FILTER Indicator Light  
NIGHT MODE Indicator Light  
QUICK CLEAN operation Indica-  
tor Light  
CLEAN-SIGN Light  
POLLEN Mode Indicator Light  
Fan Speed Indicator  
Lights  
OFF Timer Display In-  
dicator Lights  
Filter Reset Button  
Plasmacluster Indicator  
Light  
POWER ON/OFF Button  
MODE Selection Button  
Odor Sensor  
Main Unit  
Filter Frame  
True HEPA Filter (white)  
Washable Active Carbon Filter (black)  
Pre-Filter  
Front Panel  
Hook  
Remote Control  
Handle  
BACK  
Air Outlet  
Date Label  
INCLUDED  
Power Cord  
Power Plug  
Remote Control (1 unit)  
Battery (AA battery x 2 )  
• Operation manual  
(Shape of plug depends on country.)  
E-8  
PREPARATION  
INSERTING BATTERIES IN THE REMOTE CONTROL  
Remove the back cover  
Press and slide the back cover to  
remove.  
1
Insert batteries  
Insert batteries with  
shown below.  
2
and  
as  
Close the back cover  
3
Battery Information  
• The battery life is about 1 year.  
• The batteries for this remote control are for initial use only . Change the batteries  
when necessary.  
• Incorrect usage of the batteries may cause battery fluid leakage and/or damage.  
Take care of the following when handling:  
• When replacing the batteries, replace both batteries with new ones of the same  
type. (Use 2 AA manganese batteries.)  
• When not using the unit or remote control for an extended period, remove the  
batteries.  
REMOTE CONTROL USE  
Operate the remote control facing the main unit  
receiver.  
The signal range is about 23 feet (7m).  
OPERATION  
Receiver  
Make sure there are no objects blocking the  
path of the signal.  
•A beep sound will be heard from the main unit  
when a signal is received.  
Transmitter  
NOTE  
Avoid dropping or damaging the remote  
control, using in a high humidity condition, in  
direct sunlight or near a heat source.  
E-9  
Be sure to remove the power plug from the wall outlet.  
PREPARATION  
FILTER INSTALLATION  
To maintain the quality of the filters, they are installed in the main unit and packed in  
plastic bags. Be sure to remove the filters from the plastic bags before using the unit.  
Remove the filters  
1
Front Panel  
Remove the Front  
Panel.  
1
2
1
Pull the bottom of the  
Front Panel.  
1
2
1
Hook  
Pull out the Filter Frame and remove the Pre-Filter,  
Active Carbon Filter and True HEPA Filter.  
2
1
Filter Frame  
Pre-Filter  
2
Remove the Active Carbon Filter  
(black) and True HEPA Filter (white)  
from the plastic bags.  
3
True HEPA Filter  
Active Carbon Filter  
Pre-Filter  
Active Carbon Filter  
True HEPA Filter  
Filter Frame  
E-10  
Install the filters  
2
HEPA Filter  
Filter Frame  
Place the True HEPA Filter  
within the Filter Frame with  
the tabs facing up.  
1
Do not install the filter backwards or  
the unit will not operate properly.  
Band  
Place the Active Carbon Filter  
on top of the True HEPA Fil-  
ter with the bands (2 places)  
facing up.  
2
3
Active Carbon Filter  
True HEPA Filter  
Filter Frame  
Place the Pre-filter through  
the bands (2 places) located  
at the corners of the Active  
Carbon Filter.  
Tabs (4 places)  
Band  
Insert the tabs of the pre-filter into  
the associated holes of the Filter  
Frame.  
Holes  
Mount the Filter Frame to  
the main unit.  
4
5
6
Main unit  
Fix the Front Panel to the main  
unit.  
Filter Frame  
Band  
Fill in the usage start date  
on the Date Label.  
Use the date as a guide for the  
Filter Replacement schedule.  
Date Label  
E-11  
Main Unit Controls  
OPERATION  
• AUTO  
• QUICK CLEAN  
• POLLEN  
• SILENT  
• MEDIUM  
• MAX  
• NIGHT MODE  
MAIN UNIT OPERATION  
CLEAN FILTER Indicator Light  
NIGHT MODE Indicator Light  
MODE Selection Button  
Power ON/OFF Button  
CLEAN SIGN Light  
Plasmacluster Indicator Light  
1
2
Plasmacluster  
Power ON/OFF Button  
1
2
• Used to start operation (short beep) and stop operation (long beep)  
• Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off.  
• Unless unplug the power cord, is unplugged the operation starts in the previous  
mode the unit was operated in.  
MODE Selection Button  
• The operation mode can be switched, and the Indicator Light will turn on.  
AUTO operation  
NIGHT MODE Operation  
The fan speed is automatically switched  
(HIGH*, MEDIUM, SILENT) depending  
on the amount of impurities in the air.  
The sensors detect the impurities for ef-  
ficient air purification.  
The fan speed is automatically  
switched between MEDIUM and  
SILENT, depending on the  
amount of impurities in the air.  
The Plasmacluster Indicator  
Light and Clean-Sign Light will  
turn off.  
QUICK CLEAN operation  
The unit will operate at HIGH* fan speed  
for 15 minutes, then will operate at Auto  
operation.  
The operation mode is effective when  
quick removal of impurities in the air is  
desired.  
MAX operation  
The unit will operate at a fan  
speed of MAX.  
MEDIUM operation  
POLLEN mode operation  
The unit will operate at a fan  
speed of MEDIUM.  
The unit will operate at HIGH* fan speed  
for 10 minutes, then will alternate  
between NORMAL and HIGH for 20  
minutes.  
SILENT operation  
The unit will operate quietly  
using minimal air intake.  
10 minutes: HIGH fan speed  
20 minutes: MEDIUM fan speed  
20 minutes: HIGH fan speed  
* HIGH fan speed is an intermediate  
speed between MEDIUM and MAX.  
E-12  
PLASMACLUSTER INDICATOR LIGHT  
Plasmacluster ion operation is selected using the remote control.  
Blue light  
When the Plasmacluster ion operation is in Clean Mode, or in AUTO Plasmacluster Ion Mode and the air  
in the room is impure, the Plasmacluster ions will be released continuosly.  
Green light  
When the Plasmacluster ion operation is in the Ion Control Mode, or in AUTO Plasmacluster Ion Mode  
and the air in the room is clean, this light will be activated and the unit will operate in Ion Control Mode.  
Light off  
There are no Plasmacluster ions being generated.  
• The light can be turned off by using the ‘LIGHTS ON/OFF Button’ on the Remote Control. In this case,  
Plasmacluster ions are generated.  
(Please turn off the light if desired.)  
CLEAN-SIGN LIGHT  
The color changes according to the air condition.  
Clean (Green)  
Slightly Impure (Orange)  
Very Impure (Red)  
ABOUT THE CLEAN-SIGN  
• The condition of the CLEAN-SIGN depends on the room air condition detected by the Odor Sensor  
when the plug is inserted into the wall outlet.  
• It is possible to have a green CLEAN-SIGN with impurities in the air at the time that the air purifier was  
just introduced to the room environment. After a while, however, the base impurity rate will be adjusted  
to detect room air condition correctly.  
• Use the Lights ON/OFF Button on the remote control to turn off the Indicator lights if desired.  
DETERMINING THE BASE IMPURITY RATE  
For the first 30 seconds after the power plug is inserted into the wall outlet, the unit will check the condi-  
tions of the air. If operation is set to ON during this time, the CLEAN-SIGN LIGHT will alternately flash in  
green, orange and red.  
CLEAN FILTER INDICATOR LIGHT  
Clean the Pre-Filter and the Active Carbon Filter when the CLEAN FILTER Indicator Light is on.  
(The indicator light will be activated in about 2 months, when using the unit for 24 hours a day.)  
(See Page E-16)  
E-13  
Operations available with  
the Remote Control  
• AUTO  
OPERATION  
• MANUAL  
• POLLEN  
• OFF TIMER  
• NIGHT MODE  
• Quick CLEAN  
• LIGHTS ON/OFF  
REMOTE CONTROL OPERATION  
Plasmacluster Ion mode  
selections  
• AUTO  
• CLEAN  
• ION CONTROL  
• OFF  
POWER ON/OFF Button  
When you press the  
POWER ON/OFF Button, a  
short beep will sound and  
operation will start in AUTO  
Mode.  
Transmitter  
• Unless the power cord has  
been unplugged the  
operation starts from the  
previous mode the unit was  
operated in.  
Filter Reset Button  
When the Washable Active  
Carbon Filter is cleaned and  
reinserted into the main unit,  
press the Filter Reset Button.  
To stop, press the POWER  
ON/OFF Button again.  
A long beep will sound and  
operation will stop.  
Pollen Mode Operation  
Button  
See Page E-12  
Auto (Fan Speed) Button  
The fan speed switches au-  
tomatically depending on the  
amount of impurities in the air.  
Off Timer Button  
Manual (Fan Speed) Button  
The set time switches every time  
the button is pressed as shown  
below.  
The fan speed can be  
switched among SILENT,  
MEDIUM and MAX settings.  
4hours  
1 hour  
NIGHT MODE Button  
See page E-12  
8 hours  
Cancel  
QUICK CLEAN Button  
See page E-12  
• The indicator light shows the  
remaining time.  
• The unit will stop operation  
when the time is up.  
LIGHTS ON/OFF Button  
Switches the Plasmacluster  
Indicator Light and CLEAN-  
SIGN Light either ON or OFF.  
Plasmacluster Ion Mode Selections  
AUTO  
CLEAN  
When pressed, the unit will switch between Clean  
Mode and the Ion Control Mode automatically de-  
pending on the amount of impurities in the air as  
detected by the odor sensor. Clean Mode will op-  
erate for 1 minute when the Auto function is  
selected.  
When pressed, the unit will constantly  
operate in the Clean Mode, in which  
the same numbers of positive and  
negative ions are discharged. The  
Plasmacluster Indicator Light is blue.  
OFF  
ION CONTROL  
The generation of ions will be  
ceased and the Plasmacluster  
Indicator Light will go out.  
When pressed, the unit will constantly operate in  
Ion Control Mode.  
The Plasmacluster Ion Indicator Light is green.  
E-14  
CARE AND MAINTENANCE  
To maintain optimum performance of this air purifier, please clean the unit including  
the sensor and filters periodically.  
When cleaning the unit, be sure to unplug the power cord, and never handle the plug  
with wet hands. Electrical shock and/or bodily injury may occur as a result.  
MAIN UNIT  
Care Cycle 1 month  
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to  
remain, they may become hard to clean.  
Wipe with a dry, soft cloth  
For stubborn stains or dirt, use a soft cloth dampened with warm water.  
Do not use volatile fluids  
Benzene, paint thinner, polishing powder, etc., may damage the surface.  
Do not use detergents  
Detergent ingredients may damage the unit.  
Keep the unit away from water  
ODOR SENSOR  
Care Cycle 2 months  
Opening of odor  
sensor  
The sensitivity of the sensor will become  
unstable if the odor sensor is dirty or  
blocked. Remove dust from the surfaces  
of the sensor openings using a vacuum  
cleaner.  
FILTER CLEANING  
Care Cycle 2 months  
Remove the Front Panel, Clean the surface of the Pre-Filter lightly with a vacuum cleaner.  
If it is very dirty remove it from the Filter Frame and wash it.  
NOTE  
• In case of washing, use a soft brush etc. and cold/warm water.  
• Metal brushes or scrub brushes may cause damage.  
• After washing, leave it in the shade until it is dry. Then place it  
back to the frame.  
• Never wash or clean the True HEPA Filter using the nozzle of  
a vacuum cleaner directly.  
This will greatly decrease the performance of the filters.  
E-15  
CARE AND MAINTENANCE  
WASHABLE ACTIVE CARBON FILTER CARE  
Remove excess water  
HAND WASH ONLY!  
DO NOT TUMBLE DRY!  
5
The filter will be saturated with  
water after rinsing. To decrease  
drying time, wrap the filter in an  
old thick towel so that excess  
water can be removed.  
Care Cycle  
When the CLEAN FILTER Indicator Light  
illuminates, this indicates that the filter  
needs to be cleaned. If the unit is kept on  
24 hours a day then the CLEAN Filter  
Indicator Light will be activated in about 2  
months.  
CAUTION  
• Some carbon may ad-  
here to the towel, but it  
is harmless.  
• Do not wring out the  
filter.  
The CLEAN FILTER Indicator Light is for  
reference. Clean the filter as often as nec-  
essary when odor persists.  
Remove  
visible dirt  
with a  
vacuum  
cleaner.  
1
Dry the filter outdoors  
if possible in a well  
ventilated area.  
6
CAUTION  
Fill a large container up with  
warm water, add a mild  
kitchen detergent and stir.  
Dilute as indicated  
on the detergent  
container.  
• The wet filter is heavy. Fix it securely for drying to  
make sure it does not fall down.  
• The filter takes longer to dry in winter, and on rainy  
days. Wash it on a day when the weather is good  
and dry it in the sun.  
Move it indoors at night to prevent freezing.  
• Dry the filter outdoors in a well ventilated area. If  
dried indoors, the water dripping off the filter may  
soil your floor.  
2
• Make sure that the activated carbon has not shifted  
to one side inside the filter. If it has, distribute it  
evenly with your fingers.  
• Let the filter dry thoroughly.  
Allow the filter to soak ap-  
proximately 30 minutes be-  
fore washing.  
If used while the filter is still moist, then the air that  
is exhausted from the main unit will have an odor.  
It may take 1 or 2 days to dry.  
3
If the filter surface  
is very dirty, scrub  
with an old tooth-  
brush.  
Reinstalling the Filter.  
Reinstall the filter as shown on Page E-10,11  
7
8
Once the Active Carbon Filter has  
been cleaned, connect the power  
cord to the outlet and press the Filter  
Reset Button on either the Remote  
Control or Main Unit.  
• Once the Filter Reset Button has been acti-  
vated, you will hear a beep sound that means  
the unit has been reset.  
CAUTION  
Handle with care to  
prevent damage to  
the activated carbon  
particles.  
Rinse thoroughly with clean  
water  
• The Filter indicator light will then go out  
automatically.  
4
CAUTION  
If rinsing in a con-  
tainer, be sure to  
rinse 3 to 4 times so  
that the odor is  
rinsed thoroughly  
from the filter.  
Filter Reset Button  
E-16  
FILTER REPLACEMENT GUIDELINES  
Depending on the usage environment, air outlet odor may become strong  
after several months.  
If dust or odors cannot be removed easily, replace the filters.  
(Refer to please read before operating new Air purifier E-0)  
Guide for filter replacement timing  
• Filter life can be greatly reduced in poor environments.  
The presence of cigarette smoke, pet dander and other concentrations of airborne particles  
will cause filters to become clogged in less time. Please check filters regulary and replace as  
needed.  
• True HEPA Filter  
• Active Carbon Filter  
Up to 5 years after opening  
Up to 5 years after opening  
REPLACING THE FILTERS  
See page E-10,11 for directions on how  
1
to install the filters when replacing.  
After replacing the filters:  
Be sure to press the Filter Reset Button on either  
the Remote Control or Main Unit with the power cord  
connected to the outlet.  
2
A short beep will be heard and the operation hours  
stored in the memory will be reset.  
The CLEAN FILTER Indicator Light will then go out  
automatically.  
Fill in the usage start date of the filters  
on the Date Label.  
3
Replacement Filters  
Model: FZ-P65HFU  
Date Label  
• True HEPA Filter : 1 unit  
• Active Carbon Filter: 1 unit  
Please consult your dealer for purchase of  
replacement filters.  
Disposal of Filters  
Please dispose of replaced filters according to the local disposal laws and regulations.  
True HEPA Filter materials:  
• Filter: Polypropylene  
• Frame: Polyester  
• Microbial Control Filter: Polypropylene, Polyethylene  
Active Carbon Filter Materials:  
• Deodorizer: Activated charcoal  
• Net: Polypropylene 60%, Polyester 40%  
E-17  
TROUBLESHOOTING  
Before calling for repair, please review the list below, since the problem may not be a unit malfunction.  
REMEDY (not a malfunction)  
SYMPTOM  
• Have the batteries been depleted?  
• Are the batteries inserted correctly?  
• Is a fluorescent light in the room flickering due to service life?  
The Remote Control does not  
work  
Odors and smoke are not  
removed  
• Clean or Replace the filters if they appear to be heavily soiled.  
(Refer to E-16,E-17)  
• The air could be impure at the time the unit was plugged in.  
(Refer to E-13) Pull out the plug from the electrical outlet, and  
insert the plug one minute later.  
The CLEAN-SIGN Light  
illuminates green even when the  
air is impure  
• The sensitivity of the sensor becomes unstable when the  
opening of the odor sensor is dirty or is clogged.  
Clean the dust around the sensor opening using a vacuum  
cleaner. (Refer to E-15)  
The CLEAN-SIGN Light illuminates  
orange or red even when the air is  
clean  
The Plasmacluster Indicator  
Light remains green (or blue)  
and does not change  
• When in Ion Control Mode ( or Clean Mode), the Plasmacluster  
Indicator Light color will not change.  
• Clicking sound or ticking sound is emitted when the unit is  
generating ions.  
A clicking or ticking sound is  
heard from the unit  
• Check to see if the filters are heavily soiled.  
• Clean or Replace the filters.  
• Plasmacluster Air Purifiers emit small traces of ozone which  
may produce an odor. These ozone emissions are well below  
safety levels .  
The discharged air has an  
aroma or odor.  
• Is the unit installed in a location that is difficult for the sensor to  
detect cigarette smoke?  
• Is the odor sensor opening blocked or clogged?  
(In this case, clean the openings.) (Refer to E-15)  
The unit does not operate when  
cigarette smoke is in the air.  
• After replacing filters, connect the power cord to an outlet and  
press the Filter Reset Button on the remote control. (Refer to  
E-16)  
The CLEAN FILTER Indicator  
Light remains activated even  
after replacing filter.  
• Check to see if the Display OFF Mode on the Remote Control  
is selected. If so, press the Display ON/OFF Button on the  
Remote Control to activate the indicator light.  
(Refer to E-14)  
The Plasmacluster Indicator  
Light or the CLEAN-SIGN Light  
will not activate.  
ERROR DISPLAY  
LAMP INDICATION  
REMEDY  
Fan motor disconnected or abnormal.  
Operation stops.  
• Pressing the ON/OFF button will reset the error display, but if  
error occurs again, contact the Sharp Service Center.  
The “Silent” Fan Speed Indica-  
tor Light blinks.  
E-18  
SPECIFICATIONS  
Model  
FP-P60CX  
120V 60Hz  
MED  
Power supply  
Fan Speed Adjustment  
MAX  
72W  
SILENT  
4.0 W  
Fan  
Rated Power  
Speed  
Operation Fan Speed CFM (m /min)  
13 W  
3
233(6.6)  
52 dBA  
109(3.1)  
35 dBA  
31(0.9)  
14 dBA  
Noise Level  
2)  
330sq.ft(31m *1  
Applicable Floor Surface  
CADR(Dust/Smoke/Pollen)  
Cord Length  
209 / 213 / 205  
5.3ft(2.5m)  
16-11/32in(W)x9-1/2in(D)x22-17/32in(H)  
415mm(W)x241(D)x572(H)  
19.2Ibs(8.7kg)  
Dimensions  
Weight  
Pre-filter & True HEPA with Microbial control  
Washable Active Carbon  
Dust collection  
Filter type  
Deodorization  
Odor  
Sensors  
1 / 4 / 8 hours  
OFF timer  
Pollen / Quick CLEAN / Night Mode operation  
Replacement filter [Model : FZ-R65HFU]  
Special Program Mode  
Optional accessories  
•The applicable floor surface area is appropriate for operating the unit of maximum fan speed.  
*1  
Standby Power  
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this  
product consumes about 0.3W of standby power.  
For energy conservation, unplug the power cord when the unit is not in use.  
E-19  

Omega Lift Magic Lift 29023 User Manual
Opti Ups Charger Station User Manual
Ricoh Aficio Mp C3300 User Manual
Samsung Fx600 User Manual
Savin 2555 User Manual
Schumacher 9500a User Manual
Schumacher 94085896 User Manual
Universal Power Group 55a User Manual
Xerox Workcentre Pro 65 User Manual
Xerox Workcentre Pro 765 User Manual