AF-S80CX
AF-R80CX
AF-R85CX
ROOM AIR CONDITIONER
INSTALLATION AND OPERATION
MANUAL
CONTENTS
PAGE
FOR YOUR PROTECTION.................... 2
CONSUMER LIMITED WARRANTY ..... 3
INSTALLATION INSTRUCTIONS
• CHECK WINDOW AREA ........................ 4
• LOCATlON .............................................. 4
• ACCESSORIES ...................................... 5
• SUGGESTED TOOLS ............................ 5
• INSTALLATION....................................... 6
PRECAUTIONS
• CAUTION FOR USE ............................ 8
• GROUNDING INSTRUCTIONS ........... 8
• NOTES ON OPERATION .................... 9
• ENERGY EFFICIENCY TIPS............... 9
HOW TO OPERATE
• PARTS NAMES ...................................10
• COOLING OPERATION ......................11
•
•
TO CHANGE TEMPERATURE SETTING .......... 11
TO CHANGE FAN SPEED AND OPERATION MODE.. 12
• ENERGY SAVER .................................13
This INSTALLATION AND OPERATION
MANUAL explains the proper use of your new
Sharp Air Conditioner. Read these instructions
carefully before installing or operating your air
conditioner. The INSTALLATION AND OP-
ERATION MANUAL should be kept in a safe
place for handy reference.
•
TO CHANGE AIR FLOW DIRECTION ....... 13
• ON TIMER OPERATION .....................14
• OFF TIMER OPERATION....................15
• USING THE REMOTE CONTROL.......16
CLEANING AND MAINTENANCE ........ 18
BEFORE CALLING FOR SERVlCE...... 19
As an ENERGY STAR Partner, Sharp Electronics has determined that this product (AF-S80CX) meets the
ENERGY STAR guidelines for energy efficient air conditioners. To meet these guidelines, air conditioners
must be at least 15% more efficient than the minimum Federal standard.
CONSUMER LIMITED WARRANTY
CONSUMER LIMITED WARRANTY
SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"),
when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option,
either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to
the purchaser for parts or labor for the period(s) set forth below.
This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below nor
to any Product the exterior of which has been damaged or defaced, which has been subjected to improper voltage or other misuse,
abnormal service or handling, or which has been altered or modified in design or construction.
In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth below and provide proof
of purchase to the servicer.
The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law. ALL
IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE LIMITED
TO THE PERIOD(S) FROM THE DATE OF PURCHASE SET FORTH BELOW. Some states do not allow limitations on how long
an implied warranty lasts, so the above limitation may not apply to you.
Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those described
herein, or to extend the duration of any warranties beyond the time period described herein on behalf of Sharp.
The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shall be the sole and exclusive
remedy available to the purchaser. Correction of defects, in the manner and for the period of time described herein, shall constitute
complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product, and shall constitute
full satisfaction of all claims, whether based on contract, negligence, strict liability or otherwise. In no event shall Sharp be liable,
or in any way responsible, for any damages or defects in the Product which were caused by repairs or attempted repairs performed
by anyone other than an authorized servicer. Nor shall Sharp be liable or in any way responsible for any incidental or consequential
economic or property damage. Some states do not allow the exclusion of incidental or consequential damages, so the above
exclusion may not apply to you.
THIS WARRANTY GIVES YOU SPECIFlC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM
STATE TO STATE.
AF-S80CX, AF-R80CX, or AF-R85CX Room Air Conditioner. Be sure to
have this information available when you need service for your Product.
Your Product Model Number & Description:
Warranty Period for this Product:
One (1) year parts and labor from date of purchase. The warranty
period continues for a total of five (5) years from date of purchase for
the Sealed Cooling System parts; labor and service are not provided
free of charge for this additional period.
Additional Item(s) Excluded From
Warranty Coverage (If any):
Appearance items of the Product, knobs, filter, or accessories, mounting
kit, seals, or any printed materials.
Where to Obtain Service:
From a Sharp Authorized Servicer located in the United States. To find the
location of the nearest Sharp Authorized Servicer, call Sharp Toll Free at
1-800-BE-SHARP.
What to Do to Obtain Service:
Contact your Sharp Authorized Servicer to obtain in-home service for this
Product. The Servicer will come to your home, and if it is necessary to
remove the Product, the Servicer will reinstall it. Be sure to have Proof of
Purchase available.
OR CALL 1-800-BE-SHARP.
SHARP ELECTRONICS CORPORATION
Sharp Plaza, Mahwah, New Jersey 07430-2135
3
INSTALLATION INSTRUCTIONS
Before beginning installation, read these instructions carefully.
Use the enclosed MOUNTING KIT for proper installation.
CHECK WINDOW AREA
The mounting kit is designed for wooden sill double or single hung sash-type windows.
Minimum opening
Mounting kit fully closed
Mounting kit fully opened
(Without mounting kit)
19 11/16" (500mm)
5
7
21 /8" (600mm)
33 /16" (900mm)
Window opening from stool to lower
sash bottom must be 14 27/32" (377mm)
or more.
Lower sash bottom
Stool
LOCATION
• The air conditioner should be installed on a firm foundation to minimize noise and vibration.
For safe installation, repairs, replacement and secure positioning, make sure foundation is
solid and level.
• The room air conditioner must be installed in an area within reach of a properly rated
grounded outlet.
• Use of extension cords of any kind is not recommended.
• Never place any obstacles around air inlet.
4
INSTALLATION INSTRUCTIONS
ACCESSORIES
1
No.
Accessories
Q'ty
1
1
2
3
Right closure assembly
Left closure assembly
Window sash foam seal
2
1
1
3
4
Window sash foam seal
(adhesive type)
1
4
5
6
7
8
Bottom gasket
1
7
6
2
1
2
1
Screws (L=1", 25.4mm)
Screws (L= 13/32", 10mm)
Base pan angle
5
6
7
6
7
9
10
11
Remote control
Battery
8
Remote control hook
2
9
11
10
2
SUGGESTED TOOLS
1. Screw driver (medium size Phillips)
2. Tape measure or ruler
3. Knife or scissors
5
INSTALLATION INSTRUCTIONS
INSTALLATION
WARNING: Make sure the unit is turned off and unplugged before working.
Sash
Cut the window sash foam seal (adhesive
type) to the proper length and attach it to
the underside of the window sash.
1
Window sash foam seal
(adhesive type)
Jamb
Sill
Insert the right closure assembly and the
left closure assembly into the top angle
and the bottom channels.
Secure the right and left closure to the
cabinet with six of the provided screws.
(L= 13/32", 10mm)
2
3
Closure assembly
Open the window sash and place the air
conditioner on the sill.
Balance the unit on the sill and close the
window sash securely behind the top
angle.
WARNING:
unit
At this step, make sure the unit is inclined
approximately 1 cm (3/8") to the back.
If the unit is not properly inclined, the water
collected in the bottom tray during opera-
tion will not drain properly and may flow into
the room where the air conditioner is in-
stalled.
sill
incline backwards approximately
3
8
1cm ( / ")
Insert the bottom gasket into the space
between the window sill and the bottom of
the unit to seal outside air.
4
If there is space between the bottom
channel and the sill, fill the gap with a thin
board or other hard filler.
Bottom gasket
6
INSTALLATION INSTRUCTIONS
Closure assembly
(Left)
Insert the closure assemblies on both
sides into the rails of the jamb.
5
6
Jamb
(Left)
Indoor
side
Closure assembly
(Left)
Indoor
side
1/2 inches
(13mm)
Sill
Stool
Loosen screws on both sides of the
cabinet, then hang the base pan angle
on and secure the screws again.
Secure the base pan angle to the sill by
using the hole of the front side on the
angle with one screw. (L=1", 25.4mm)
7
8
Top angle
Secure the top angle of the unit and the
top of the closure assemblies to the sash
with three of the provided screws. (L=1",
25.4mm)
And secure the bottom of the closure
assemblies to the sill with two of the
provided screws. (L=1", 25.4mm)
Cut the window sash foam seal to the
proper length and seal the opening be-
tween the top of the inside window sash
and the outside window sash.
9
Window sash foam seal
7
PRECAUTIONS
CAUTION FOR USE
IMPORTANT: Points to keep in mind when using your air conditioner.
• Install the air conditioner by following the installation instructions given in the previous
section of this manual.
• Make sure the unit is the correct capacity for the area you want to cool.
• Do not modify any part of this product.
• Do not insert objects into any part of the unit.
• Push the AC power plug securely into the receptacle and make sure it is not loose.
• Use power circuit with a proper voltage rating.
Use a three-pronged grounded electrical outlet rated 125V, 60Hz,
15 amp or more, AC only as shown on right.
Use of an improper voltage rating power circuit can result in
damage to the unit and possibly fire.
Two-Pole, 3-wire Grounding
Receptacle 15 Amps. 125V.
• Always use a fuse with the proper amp rating.
Do not, under any circumstances, use wire, pins or other objects in place of the proper fuse.
• Use of extension cords of any kind is not recommended.
If you still elect to use an extension cord, it is absolutely necessary that it be a UL Listed 3-wire grounding
type appliance extension cord rated 125 Volts, 15 amp or more.
• Ventilate the room periodically during use, especially if using gas appliances.
GROUNDING INSTRUCTIONS
WARNING: Improper use of the grounding plug can result in the risk of electric shock.
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk
of electric shock by providing an escape wire for the electric current.
This appliance is equipped with a cord having a grounding wire with a grounding plug.
The plug must be plugged into an outlet that is properly installed and grounded.
WARNING: Do not under any circumstances cut or remove the round grounding prong
from this plug.
If it is necessary to use an extension cord, use only a UL Listed 3-wire extension cord that has a 3-
blade grounding plug, and a 3-slot receptacle that will accept the plug on the appliance.
The marked rating of the extension cord should be AC 125 Volt, 15 Amp or more.
Consult a qualified electrician or serviceman if the grounding instructions are not completely under-
stood, or if doubt exists as to whether the appliance is properly grounded.
If a grounding adapter is used, make sure the receptacle box is fully grounded.
Grounding adapter
3-Pronged receptacle
Grounded receptacle box
Grounded
receptacle box
Grounding wire
3-Pronged plug
Screw
Tab for grounding screw
Grounding prong
8
PRECAUTIONS
NOTES ON OPERATION
•
•
Allow 3 minutes for the compressor to restart cooling.
If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to
restart cooling. There is an electronic device in the unit that keeps the compressor off three minutes for
protection.
If a power failure occurs during use, allow 3 minutes before restarting the unit.
After power is reinstated, restart the air conditioner. If the power was off for less than three minutes, be
sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within three
minutes, a protective device in the unit may cause the compressor to shut off. This protective device will
prevent cooling for about 5 minutes.
Memories of previous settings will be canceled and the unit will return to each initial setting.
• Dehumidifying function
The air conditioner removes moisture from the air in your room.
•
Cooling operation under low temperatures: Is your unit freezing up?
The unit operates on inside and outside temperatures. Freezing can occur when the temperature is set
close to 64°F and when there are low outside temperatures, especially during the night hours. At these
conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher
temperature will prevent it from freezing.
ENERGY EFFICIENCY TIPS
• Setting the proper temperature.
For optimum energy efficiency, keep the difference between the inside and outside temperature within
10°F(5°C). Do not keep the temperature setting any lower than is necessary for you to feel comfortable.
Generally, 78°F to 80°F(26°C to 27°C) is a comfortable summer indoor temperature.
When you turn the unit on, do not set the temperature higher than the room temperature at start up as
this will not allow the compressor to cycle and maintain a comfortable room temperature.
• Avoid direct sunlight.
Close blinds, drapes or shades to keep out direct sunlight during cooling operation.
• Keep the filter clean.
Keeping the filter clean greatly aids efficient operation. A dirty filter blocks the flow of air, making your air
conditioner work harder and less efficiently. See page 18 on how to clean the filter.
• Turn off unnecessary light.
Your air conditioner must remove the heat produced by your lights or other heat-producing appliances.
Turn off lights or appliances that are not in use.
• Install your air conditioner in a shady location.
Direct sunlight on a window air conditioner increases its workload and will increase its operating cost.
• Don't let cool air escape.
Close windows and outside doors. Do not keep doors open and let hot air rush in. Improperly installed
air conditioners and improperly weatherstripped doors and windows will let hot air in and the cool air out.
• Turn off air conditioner when no one is home.
Use only when necessary. The fewer hours a room air conditioner is used, the lower the operating cost.
9
HOW TO OPERATE
PARTS NAMES
UNIT
1Front Cabinet
4
5
6
3
2Air Inlet (Indoor Side)
3Horizontal Louvers
4Vertical Louvers
5Air Outlet (Indoor Side)
6Control Panel
7
8
9
7Rear Cabinet
8Air Inlet (Outdoor side)
9Filter (Pull the filter handle
to the right to remove.)
0Filter Handle
10
2
1
11
qPower Cord
CONTROL PANEL
AF-S80CX, AF-R80CX
AF-R85CX
2
1
2
1
F
F
hr
hr
COOL
/
FAN TEMP
COOL
/
FAN TEMP
3
3
ENERGY
SAVER
TIMER
ON/OFF
POWER
ON/OFF
SELECTOR
POWER
ON/OFF
TIMER
ON/OFF
ENERGY
SAVER
SELECTOR
7
9
11
7
9
11
10
10
4
5
6
8
4
5
6
8
1Receiver window for remote control signal
2Display
3SELECTOR indicator
4SELECTOR pad
6TIMER ON/OFF pad
7TIMER indicator
8ENERGY SAVER pad
9ENERGY SAVER indicator
0POWER ON/OFF pad
qPOWER indicator
5TEMPERATURE setting pad
----Lower temp.
----Raise temp.
10
HOW TO OPERATE
COOLING OPERATION
Touch POWER ON/OFF pad.
POWER
1
2
• The unit is preset at 74°F and HIGH
COOL. This will show in the display
when the power is first turned on.
• POWER indicator and SELECTOR in-
dicator (COOL) will light.
SELECTOR indicator
indicator
F
hr
COOL / FAN TEMP
To turn off the unit, touch POWER
ON/OFF pad again.
• POWER indicator and SELECTOR
indicator will go off.
ENERGY
SAVER
TIMER
ON/OFF
SELECTOR
POWER
ON/OFF
POWER ON/OFF pad
TO CHANGE TEMPERATURE SETTING
During cooling operation
Touch the TEMPERATURE setting
pad to adjust the temperature set-
ting.
F
hr
COOL / FAN TEMP
---Lower temp.
---Raise temp.
ENERGY
SAVER
TIMER
ON/OFF
SELECTOR
POWER
ON/OFF
• Temperature can be set within the range
of 64°F to 86°F.
• Display will change as you touch
the pad.
TEMPERATURE setting pad
NOTE:
• The latest temperature setting will be memorized and will appear on the display the next time
the unit is turned on.
• In cases of power outages or when the unit is disconnected; when the power is restored or the
unit is plugged in, the unit and display will return to the preset conditions of 74°F and HIGH
COOL. The unit will not automatically turn back on. The user must touch POWER ON/OFF to
resume opertion.
11
HOW TO OPERATE
TO CHANGE FAN SPEED AND OPERATION MODE
SELECTOR indicator
During operation
Touch SELECTOR pad and select the
operation mode and fan speed.
F
hr
• SELECTOR indicator and display will light
in order as you touch.
COOL / FAN TEMP
ENERGY
SAVER
TIMER
ON/OFF
SELECTOR
POWER
ON/OFF
HIGH COOL
LOW FAN
MED COOL
MED FAN
LOW COOL
HIGH FAN
SELECTOR pad
NOTES ON OPERATION MODE:
SELECTOR
DISPLAY
MODE
Cooling operation with high fan speed.
Cooling operation with medium fan speed.
Cooling operation with low fan speed.
Fan only operation with high fan speed.
Fan only operation with medium fan speed.
Fan only operation with low fan speed.
COOL
HIGH COOL
MED COOL
COOL
LOW COOL COOL
HIGH FAN
MED FAN
LOW FAN
FAN
FAN
FAN
• The latest operation mode will be memorized and the selector indicator and display will light
when the unit is turned on.
• In fan only operation, the temperature display will go off.
• When the SELECTOR is changed to fan only operation from cooling operation, it will take 5
seconds for the compressor to stop.
12
HOW TO OPERATE
ENERGY SAVER
During normal operation, the thermostat automatically controls cooling and the fan runs continu-
ously. When the ENERGY SAVER is selected, the thermostat automatically controls cooling and
the fan automatically stops when the compressor is not operating. (Fan will stop 30 seconds after
the compressor stops. Even after the fan stops, the fan will rotate for 2 minutes, every maximum
20 minutes, to detect room temperature.)
During cooling operation
Touch ENERGY SAVER pad.
1
F
• ENERGY SAVER indicator will light.
hr
COOL / FAN TEMP
To cancel, touch ENERGY SAVER
pad again.
• ENERGY SAVER indicator will go
off.
ENERGY
SAVER
TIMER
ON/OFF
SELECTOR
POWER
ON/OFF
2
ENERGY SAVER pad
ENERGY SAVER indicator
NOTE: ENERGY SAVER cannot be set during fan only (HIGH FAN, MED FAN, LOW FAN)
operation.
TO CHANGE AIR FLOW DIRECTION
The horizontal louvers are used to adjust the UP / DOWN direction of air flow, and the vertical
louvers are used to adjust the LEFT / RIGHT direction of air flow for uniform and efficient cooling
of the room.
Horizontal louvers
Vertical louvers
Lever
Adjust UP/DOWN air flow
Adjust LEFT/RIGHT air flow
13
HOW TO OPERATE
ON TIMER OPERATION
• This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance.
You can set the timer to start in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance
of the start time, or in 1 hour increments from 10 to 12 hours in advance of the start time.
• The unit will start automatically according to your setting.
When the unit is not operating
SELECTOR indicator
Touch the TIMER ON/OFF pad to set the
1delayed start time.
F
• The time setting will change as you touch the
pad. The display will change as follows;
hr
COOL / FAN TEMP
Preset(0.5h)
Previous setting
1.0h
0.5h
1.5h 10h
12h 11h
ENERGY
SAVER
TIMER
ON/OFF
SELECTOR
POWER
ON/OFF
CL(cancel)
• The timer will be set, 5 seconds after the
TIMER ON/OFF pad is touched for the last
time.
TIMER ON/OFF pad
TIMER indicator
• SELECTOR indicator and TIMER indicator
will light.
(If you wish to start the operation
6 hours and 30 minutes later, set
the delay time as shown above.)
• The time display will count down the remain-
ing time.
• The unit will start when the set time expires.
The temperature setting will be displayed.
TO CANCEL THE TIMER SETTING
Touch the TIMER ON/OFF pad again after the
timer is set, or press the TIMER ON/OFF pad
until CL(cancel) appears on the display.
NOTES FOR TIMER SETTING AND OPERATION:
• After setting the TIMER, change the temperature and fan speed settings as shown on pages 11
and 12. When the temperature is set in the timer mode, the temperature will show in the display
for 5 seconds and then return to the time display.
• The last setting used will be memorized and will appear on the display the next time you operate
the unit with the TIMER function.
• If a power failure occurs while the ON or OFF TIMER is set, the TIMER memory will be cancelled
and will not resume even after power is reinstated. The unit will not automatically start.
• OFF TIMER OPERATION can also be set with the REMOTE CONTROL.
14
HOW TO OPERATE
OFF TIMER OPERATION
• This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance.
You can set the timer to stop in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance
of the stop time, or in 1 hour increments from 10 to 12 hours in advance of the stop time.
• The unit will stop automatically according to your setting.
When the unit is operating
Touch the TIMER ON/OFF pad to set the
1 delayed stop time.
F
• The time setting will change as you touch the
pad. The display will change as follows;
hr
COOL / FAN TEMP
Preset(0.5h)
Previous setting
1.0h
0.5h
1.5h 10h
12h 11h
ENERGY
SAVER
TIMER
ON/OFF
SELECTOR
POWER
ON/OFF
CL(cancel)
• The timer will be set, 5 seconds after the
TIMER ON/OFF pad is touched for the last
time.
TIMER ON/OFF pad
TIMER indicator
• TIMER indicator will light.
• The time display will count down the remain-
ing time.
(If you wish to stop the operation
10 hours later, set the delay time
as shown above.)
• The unit will stop when the set time expires.
All indicators and displays will go out.
TO CANCEL THE TIMER SETTING
Touch the TIMER ON/OFF pad again after the
timer is set or, press the TIMER ON/OFF pad until
CL(cancel) appears on the display.
15
HOW TO OPERATE
USING THE REMOTE CONTROL
INSTALLING BATTERIES
Use two size-AAA (R03) batteries.
Remove the battery compartment cover.
1
2
Insert the batteries in the compartment,
making sure the
and
polarities
are properly aligned.
Battery compart-
ment cover
Replace the cover.
3
NOTES:
• The battery life is approximately one year with normal use.
• When you replace the batteries, always use two new ones of the same type.
• If the remote control does not operate normally after replacing the batteries, take out the
batteries and replace them again after 30 seconds.
• If you will not be using the unit for a long time, remove the batteries from the remote control.
ATTACHING THE REMOTE CONTROL HOOK
• Remove the backing from the remote control hook.
• Attach the hook onto the left side of the unit's front
cabinet.
Rear Cabinet
• To prevent loss, hook the remote control on the front
cabinet when not in use.
Front Cabinet
Remote control hook
HOW TO USE THE REMOTE CONTROL
Point the remote control towards the unit's re-
ceiver window and press the desired button. A
beep will sound when the unit receives the signal.
• Make sure no objects, such as curtains, block the
receiver window.
• The remote control operates from up to 20 feet (6
meters) away.
• The beep will also sound when each pad on the
control panel is touched.
CAUTION:
• Do not expose the receiver window to direct sunlight. This can adversely affect its operation. In
such case, close the curtains to block the sunlight.
• Use of a fluorescent lamp in the same room may interfere with the transmission of the signal.
• The unit may be affected by signals emitted from the remote control of a television, VCR or other
equipment used in the same room.
• Do not leave the remote control exposed to direct sunlight or near a heater. Protect the remote
control from moisture and shock which can discolor or damage it.
16
HOW TO OPERATE
OPERATING WITH THE REMOTE CONTROL
TRANSMITTER
POWER
ON/OFF
POWER ON/OFF button
Push to start or stop the operation.
TEMP.
TEMPERATURE setting button
TEMP.
TEMP.
---Raise temp. setting 1°F at a time.
---Lower temp. setting 1°F at a time.
TEMP.
HIGH COOL
MED COOL
LOW COOL
SELECTOR
SET TIMER/OFF
SELECTOR button
Push to change fan speed and operation
mode.
Fan speed and operation mode
selections are shown to the right.
HIGH FAN
MED FAN
LOW FAN
SET TIMER/OFF button
Push to set delay "OFF" timer during operation.
• The time setting will change as you push the button. The display
will change as follows;
Preset(0.5h)
Previous setting
1.0h
0.5h
1.5h
10h
CL(cancel)
12h
11h
• The last OFF time setting is memorized by the unit and will
appear on the display when the button is pushed.
• The timer will be set, 5 seconds after the SET TIMER/OFF button
is pushed for the last time.
• If you wish to cancel the timer, push the SET TIMER/OFF button
again after the time is set or, push the SET TIMER/OFF button
until CL (cancel) appears on the display. A double beep will
sound when the timer is cancelled.
• The "ON" TIMER cannot be set with the remote control.
It can only be activated by the TIMER ON/OFF pad on the unit's
control panel ( See page 14 ).
To change temperature setting when ON/OFF timer is in use
1. Push a TEMPERATURE setting button.
The current set temperature will be recalled on the unit's display.
2. Use the TEMPERATURE setting buttons to set the new temperature.
The new set temperature will show on the display for 5 seconds and return to
the time display.
17
CLEANING AND MAINTENANCE
CLEANING THE FILTER
If the filter is clogged with dust, the amount of air flow will
be reduced, resulting in poor cooling performance. The
filter should be cleaned every 10 days. At the beginning of
every cooling season or after a long period of inactivity,
clean the filter before starting the unit.
REMOVE THE FILTER
1
Gently pull the filter handle to the right and slide the
filter out from the unit.
CLEAN THE FILTER
2
To remove dust from the filter, use a vacuum cleaner
or wash it in clean water.
If the filter is very dirty, wash it with detergent and
rinse carefully with clean water. Dry the filter with
a soft cloth.
Do not expose the filter to heat or dry it in direct
sunlight.
RE-INSTALL THE FILTER
3
Align the filter behind the front panel.
Grasp the filter handle and gently push the filter back
into place.
Never operate the unit without installing the filter. It
may result in serious damage to the unit.
CLEANING OF THE FRONT PANEL AND CABINET
To clean the front panel and cabinet, wipe with a soft, dry cloth or with a cloth moistened with a
mild soap. Rinse carefully by wiping with a damp cloth and dry completely.
Avoid splashing the unit with water. Excess water can damage electrical insulation and result in
danger.
Never use harsh chemicals or abrasive cleaners on any part of the unit. To avoid damage to the
unit, do not use hot water (120°F / 50°C or more) when cleaning.
OILING OF THE COMPRESSOR AND FAN MOTOR IS
UNNECESSARY
The compressor is permanently lubricated and is hermetically sealed. The fan motor is
lifetime sealed and does not require oiling.
18
BEFORE CALLING FOR SERVlCE
IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK
THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE.
AIR CONDITIONER DOES NOT OPERATE AT ALL
• Is the unit plugged in or is the plug loose?
• Is the fuse blown or the circuit breaker tripped?
• Did you restart the unit within 3 minutes after a power failure? If the power was off for less than 3
minutes, and you restarted the air conditioner within 3 minutes, a protective device may cause the
compressor to shut off, preventing cooling for about 5 minutes.
AIR CONDITIONER DOES NOT PROPERLY COOL
• Is the SELECTOR set to fan only (HIGH FAN, MED FAN, LOW FAN) mode?
Cooling will not take place in the fan only mode. Change the SELECTOR setting.
• Is the filter clogged with dust?
A dirty filter can cause the cooling coils to freeze. If this happens, clean the filter and replace. Run
the air conditioner on the MED FAN setting until all ice dissipates.
• Is the temperature set properly?
If your room is too warm, adjust the temperature setting lower.
If your room is too cool, adjust the temperature setting higher.
• Is the window exposed to direct sunlight?
Close curtains or blinds to minimize solar energy heating the room.
• Are the windows or doors open?
Close all windows and doors for maximum cooling.
TIMER DOES NOT WORK PROPERLY
• If a power failure occurs while the ON or OFF TIMER is set, the TIMER setting will be cancelled and
will not resume even after the power is reinstated. This is the normal operation for this unit.
NOTE: WATER IN BOTTOM OF TRAY
• Water will collect in the bottom tray of the unit. This is normal. Water condenses on the evaporator
coil at the front of the unit and is channeled to the rear where it is picked up by the condenser fan.
The water is blown onto the condenser coil fins and this creates a "splashing" noise which is normal.
If excess water builds up in this tray it will drain outside through a grooved channel in the tray.
SOUNDS
• The operating sound may seem rather loud for 2 to 3 minutes when the unit is first turned on. This
is the sound of the compressor's start-up and is normal.
• A soft, swishing noise can be heard immediately after the unit is turned on or off, and also during
operation. This is the sound of the refrigerant flowing inside the unit.
IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL
• Check the remote control batteries. Replace if necessary.
• Try to send the signal again with the remote control pointed directly at the unit's receiver window.
• Check whether the remote control batteries are installed with the polarities properly aligned.
19
SHARP ELECTRONICS CORPORATION
Sharp Plaza, Mahwah, New Jersey 07430-2135
SHARP CORPORATION
Osaka, Japan
Printed in Thailand
TINSEA292JBRZ 01LO
TL
1
|