Print Form
Split System Submittal Data
System: 09KLS71 Indoor/Outdoor: KS0971/CL0971
Wall Mounted Low Ambient Air Conditioner
Job Name:
Location:
Approval:
Date:
Engineer:
Construction:
Unit #:
Drawing #:
Submitted to:
Submitted by:
Reference:
General Data (at 115V)
Power
V/PH/Hz
115/1/60
Circuit Ampacity
Fuse Size, Max.
(A)
(A)
20
20
Refrigerant
Lbs. - R410a (outdoor unit)
Control
R410A
2.09
Electric Expansion Valve
Compressor
No. used
R.L. Amps - L.R.
Crankcase Heater
DC Rotary Inverter
1
7.6 - 20
20
Flare
50
23
Connection
(A)
(W)
Line Length, Max
Lift Difference, Max
Line Size
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
(in. O.D. Discharge)
(in. O.D. Suction)
1/4”
3/8”
Line Size
Propeller
15-3/4-1
DC Motor
8 - 750
50 - 1
Dimensions
(in.)
H x W x D
Indoor Unit
(RPM)
(W)
(Uncrated)
(Crated)
11-7/32 x 32-15/32 x 7-7/16
13-25/32 x 35-7/16 x 10-1/32
No. Motors
(High)
883
CFM
Outdoor Unit
(Uncrated) 21-9/16 x 28-11/32 x 10-7/16
(A)
0.6
F.L. Amps
(Crated)
23-5/8 x 33-11/16 x 14-1/4
Aluminum Fin & Copper Pipe
Corrugated Plate - Inner Riffeled
Coil Type
Weight
Net
Shipping
Indoor
19.8
24.3
Outdoor
72.8
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(lbs.)
(lbs.)
2 - 18.1
3.1
5/16”
79.4
(sq.ft.)
(in.)
Tube Size
Indoor
2.82
Outdoor
6.36
Shipping Volume
(cu.ft.)
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Performance Data @ ARI Standard Conditions (115V)
Cooling
Cross Flow
3-11/16 24-31/32 - 1
3 & Auto
Total Capacity
Sensible Capacity
Latent Capacity
SEER
(BTU/H)
(BTU/H)
(BTU/H)
9,000 (3,000-9,000)
(RPM, High)
(W)
(HI/Med/Lo)
4 - 1200
16 - 1
282/247/200
7,650
1,350
16
3.4
Indoor Sound Rating
F.L. Amps
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating
(Pints/H)
(A)
(W)
(Hi) (dB-A)
(A)
34
0.45
7.6 (2.5-7.6)
755 (250-755)
46
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riffeled
2 - 19.5
(dB-A)
Face Area
(sq.ft.)
2.02
Tube Size
Drain Connection Size
(in.)
(in.)
9/32”
23/32”
|