PREPARING YOUR AIR CONDITIONER
◆◆◆Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
◆◆◆View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
◆◆◆Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . 6
◆◆◆Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
◆◆◆Inserting the Remote Control Batteries . . . . . . . . . . . . . . . . . . . 8
◆◆◆Installing the Remote Controller Holder . . . . . . . . . . . . . . . . . . 8
◆
OPERATING YOUR AIR CONDITIONER
◆◆◆5 Way Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
◆◆◆Selecting the Automatic Operating Mode . . . . . . . . . . . . . . . . 10
◆◆◆Cooling Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
◆◆◆Changing the Room Temperature Quickly . . . . . . . . . . . . . . . 12
◆◆◆Removing Excess Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . 13
◆◆◆Airing Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
◆◆◆Adjusting the Air Flow Direction Vertically . . . . . . . . . . . . . . . 15
◆◆◆Adjusting the Air Flow Direction Horizontally . . . . . . . . . . . . . 15
◆
◆
PROGRAMMING YOUR AIR CONDITIONER
◆◆◆Setting the On Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
◆◆◆Setting the Off Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
◆◆◆Setting the Sleep Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
RECOMMENDATIONS FOR USE
◆◆◆Operating Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . 19
◆◆◆Temperature and Humidity Ranges . . . . . . . . . . . . . . . . . . . . 20
◆◆◆Cleaning Your Air Conditioner . . . . . . . . . . . . . . . . . . . . . . . . . 21
◆◆◆Solving Common Problems . . . . . . . . . . . . . . . . . . . . . . . . . . 22
◆◆◆Installing a Filter (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
◆
TECHNICAL SPECIFICATIONS
E-3
View of the Unit
The design and shape are subject to change according to the model.
Indoor Unit
Air Inlet
Air flow blades (outlet)
Air filter
(under the grille)
Timer indicator
Remote Control Sensor
SAVING indicator
STANDARD indicator
NATURE indicator
SILENCE indicator
POWER indicator
On/Off & 5 Way
selection button
Note
◆ For details on the 5 Way, refer to page 9.
E-4
UM18B1C2
Outdoor Unit
Air Inlet(Rear)
Air Outlet
Connection Valve
Connection Valve
Connection Valve
UM26B1C2
Outdoor Unit
Air Inlet(Rear)
Air Outlet
UM27B1C3
Outdoor Unit
Air Inlet(Rear)
Air Outlet
E-5
Remote Control - Buttons and Display
Remote control
transmission indicator
Mode selection button
(AUTO, COOL, DRY, FAN)
Operating mode
(
AUTO,
COOL,
DRY,
FAN)
Temperature adjustment
buttons
Temperature setting
Turbo mode
Sleep mode
Turbo/Sleep mode
selection button
Fan speed
Fan speed adjustment
button
Air flow direction
Swing button
On Timer setting
On Timer button
Off Timer setting
Off Timer button
Battery discharge indicator
On/Off &
Timer Set/Cancel button
5 Way selection button
E-6
Getting Started
You have just purchased a split type air conditioner and it has been
installed by your installation specialist.
Your Owner’s Instructions contains valuable information on using your
air conditioner. Please take the time to read it as it will help you take full
advantage of the unit’s features.
The booklet is organized as follows.
◆ The following figures are shown on pages from 4 to 6 :
-
-
Indoor and outdoor units
Remote control(buttons and display)
They will help you find the buttons and understand the symbols displayed.
◆ In the main part of the installation book, you will find a series of
step-by-step procedures for each function available.
The illustrations in the step-by-step procedures use three different symbols:
PRESS
PUSH
HOLD DOWN
E-7
Inserting the Remote Control Batteries
You must insert or replace the remote control batteries when :
◆ You purchase the air conditioner
◆ The remote control does not work correctly
Note
◆ Use two AAA, LR03 1.5V batteries.
◆ Do not use old batteries or different kinds of batteries together.
◆ Batteries may be completely discharged after 12 months, even
◆ if they have not actually been used.
1
2
Push the battery cover on the rear of the remote control with your thumb
in the direction of the arrow and remove it.
Insert the two batteries, taking care to respect the polarities :
◆ + on the battery with + on the remote control.
◆ - on the battery with - on the remote control.
3
Close the cover by sliding it back until it clicks into place.
Installing the Remote Controller Holder
1
2
Place the remote controller holder on the wall.
Fix the remote controller holder by tightening the screws.
3
Put the remote controller into the holder as shown in the figure.
◆ If you want to install the holder easily, you had better install the holder
on the wooden frame.
E-8
5 Way Function
You can select the 5 Way function with operating mode of the air conditioner for
more comfortable circumstances. You can use the 5 Way function with the indoor
unit as well as the remote control. Thus, you can use this function
even though you have lost your remote control.
Using with the indoor unit
1
Press the
mode.
(ON/OFF) button one time and then select the desired
To obtain a(n)...
Then select...
Normal operating
(STANDARD) mode
Reducing the uncomfortable
temperature gradually
(NATURE) mode
(POWER) mode
(SAVING) mode
(SILENCE) mode
High fan speed
Compressor run time reduced
Fan speed reduces as the temperature
decreases
2
To stop the operating, press the
turn off.
(ON/OFF) button until all indicators
Note
Even if the air conditioner has been turned on via the ON/OFF
button on the unit, operations can still be controlled using the
remote control as usual.
Selecting with the Remote Control
To select the 5 Way function with the remote control, press the 5 Way
button one or more times until the desired mode is selected.
◆ Each time you press the 5 Way button:
Each 5 Way indicator on the indoor unit lights up in order.
E-9
Selecting the Automatic Operating Mode
You can start the air conditioner in Automatic mode from your remote
control. In the Automatic mode, the standard temperature and the
optimum fan speed is selected automatically. You can adjust the
standard temperature but not the fan speed.
1
If necessary, press the
(On/Off) button.
Result:
◆ The 5 Way indicator on the indoor unit lights up.
◆ The air conditioner starts up in the mode selected
when the unit was last used.
◆ The indoor unit beeps.
IMPORTANT
The air conditioner is fitted with a protection mechanism to
prevent the unit from being damaged when it is started
immediately after being:
◆ Plugged in
◆ Stopped
lt will start up normally after three minutes.
2
If the
is not displayed at the top of the remote control,
press the MODE button on the remote control one or more times until it
appears.
Result:
◆ The indoor unit beeps each time you press the MODE button.
◆ The air conditioner runs in AUTO mode.
Note
You can change modes at any time.
3
To adjust the standard temperature (The air conditioner automatically
set the standard temperature by the current room temperature.),
press the TEMPERATURE buttons one or more times.
SET TEMP. SET TEMP.
-4°F/-2°C -2°F/-1°C Standard temperature +2°F/+1°C +4°F/+2°C
< When you feel hot > < When you feel chilly >
-
SET TEMP. SET TEMP.
E-10
Cooling Your Room
You must select the Cool mode if you wish to adjust the:
◆ Cooling temperature
◆ Fan speed when cooling
1
If necessary, press the
(On/Off) button.
Result: The 5 Way indicator on the indoor unit lights up.
◆
◆ The air conditioner starts up in the mode selected
when the unit was last used.
◆ The indoor unit beeps.
IMPORTANT
The air conditioner is fitted with a protection mechanism to
prevent the unit from being damaged when it is started
immediately after being:
◆ Plugged in
◆ Stopped
lt will start up normally after three minutes.
2
If the
is not displayed at the top of the remote control,
press the MODE button on the remote control one or more times until it
appears.
Result:
◆
◆
The indoor unit beeps each time you press the MODE button.
The air conditioner runs in COOL mode.
Note
You can change modes at any time.
3
To adjust the temperature, press the TEMPERATURE buttons one or
more times until the required temperature is displayed.
Possible temperatures are between 65°F(18°C) and 86°F(30°C)
inclusive.
Result:
◆
Each time you press the TEMPERATURE buttons:
- The temperature is adjusted by 1°F(1°C)
- The indoor unit beeps
◆ The air conditioner starts cooling, provided that the room
temperature is higher than the selected temperature;
the fan will, however, operate.
4
Select the fan speed by pressing the FAN button one or more times
until the required setting is displayed:
Automatic (rotated :
)
Low
Medium
High
Result:
Each time you press the FAN button, the indoor unit beeps.
5
To control the direction of the air flow, refer to page 15.
E-11
Changing the Room Temperature Quickly
The Turbo cooling function is used to cool your room as quickly as possible.
Example :
You have just come home and find that the room is very
hot. You wish to cool it down as quickly as possible.
The Turbo function operates for 30 minutes with the maximum settings before
returning automatically to the mode and temperature previously selected.
1
If necessary, press the
(On/Off) button.
Result:
◆ The 5 Way indicator on the indoor unit lights up.
◆ The air conditioner starts up in the mode selected when the unit
was last used.
◆ The indoor unit beeps.
2
Press the
Result:
button.
◆ The temperature and fan settings are adjusted automatically.
◆ The air conditioner cools the room as quickly as possible.
◆ After 30 minutes, the air conditioner is reset automatically to the
previous mode, temperature and fan settings.
But, if you press the
button in DRY or FAN mode,
it will change to AUTO mode automatically.
3
If you wish to stop the Turbo function before the end of the 30-minute period,
press the
button one or more times until
or
disappears.
Result:
The air conditioner is reset automatically to the previous mode,
temperature and fan settings.
4
To control the direction of the air flow, refer to page 15.
E-12
Removing Excess Humidity
If the atmosphere in your room is very humid or damp, you can
remove excess humidity without lowering the room temperature too
much.
1
If necessary, press the
(On/Off) button.
Result: The 5 Way indicator on the indoor unit lights up.
◆
◆ The air conditioner starts up in the mode selected when
the unit was last used.
◆ The indoor unit beeps.
IMPORTANT
The air conditioner is fitted with a protection mechanism
to prevent the unit from being damaged when it is started
immediately after being:
◆ Plugged in
◆ Stopped
It will start up normally after three minutes.
2
If the
is not displayed at the top of the remote control, press the
MODE button on the remote control one or more times until it appears.
Result:
◆
◆
The indoor unit beeps each time you press the MODE button.
The air conditioner runs in DRY mode.
Note You can change modes at any time.
3
To adjust the temperature, press the TEMPERATURE buttons one or
more times until the required temperature is displayed.
Possible temperatures are between 65°F(18°C) and 86°F(30°C)
inclusive.
Result: ◆ Each time you press the TEMPERATURE buttons:
- The temperature is adjusted by 1°F(1°C)
- The indoor unit beeps
◆ The air conditioner starts removing the excess humidity;
the quantity of air is adjusted automatically.
4
To control the direction of the air flow, refer to page 15.
E-13
Airing Your Room
If the atmosphere in your room is stale, you can air the room using
the Fan feature.
1
If necessary, press the
(On/Off) button.
Result: The 5 Way indicator on the indoor unit lights up.
◆
◆ The air conditioner starts up in the mode selected when
the unit was last used.
◆ The indoor unit beeps.
2
If the
is not displayed at the top of the remote control,
press the MODE button on the remote control one or more times until it
appears.
Result:
◆
◆
◆
The indoor unit beeps each time you press the MODE button.
The air conditioner runs in FAN mode.
The temperature is set automatically.
Note
You can change modes at any time.
3
Select the fan speed by pressing the FAN button one or more times
until the required setting is displayed:
Low
Medium
High
Result: Each time you press the FAN button, the indoor unit beeps.
To control the direction of the air flow, refer to page 15.
4
E-14
Adjusting the Air Flow Direction Vertically
Depending on the position of the indoor unit on the wall of your room,
you can adjust the position of the outer air flow blade on the bottom of
the unit, thus increasing the efficiency of the air conditioner.
1
Press the SWING button one or more times as required.
Result: The outer blade is adjusted vertically.
RECOMMENDATION
When...
Adjust the blade to face...
Cooling
Upwards.
2
If you want the blade to move up and down automatically when the air
conditioner is operating, press the SWING button.
Result: The blade move up and down, around the base position set.
3
To stop the blade moving up and down, press the SWING button again.
Note
If you switch the air conditioner... Then the blade is...
Off
Closed completely.
On again
Set to the initial position powered.
Adjusting the Air Flow Direction Horizontally
There are two sets of inner air flow blades. Just as the outer air flow
blade can be adjusted vertically, the inner blades can be adjusted
horizontally.
1
Adjust each set of inner blades to the required position, by pushing or
pulling them sideways.
E-15
Setting the On Timer
The On Timer enables you to switch on the air conditioner automatically
after a given period of time. You can set the period of time from
30 minutes to 24 hours.
1
To set the operating time, press the ON TIMER button one or more times
until the required time is displayed. Possible time is between 0.5 hour and
24 hour inclusive.
2
Press the
(Set/Cancel) button to complete the setting.
Result: ◆ The remaining time is displayed.
◆ Blinking of the timer indicator stops.
◆ The selected mode and the temperature on the display
disappear after 10 seconds.
◆ The air conditioner will switch on automatically when the
counter displayed on the remote control reaches the set time
and disappears the On timer setting.
3
To select an operating mode in advance, press the
button until the
desired mode is displayed at the top of the remote control.
Result: ◆ The air conditioner will run in the selected mode when it is
turned on.
To Cancel the On Timer
1
To cancel the On Timer, press the ON TIMER button one or more times
until the timer setting disappears.
2
Press the
(Set/Cancel) button.
Note
If you want to turn on the air conditioner before the timer reaches
the setting time, press the (ON/OFF) button.
E-16
Setting the Off Timer
The Off Timer enables you to switch off the air conditioner automatically
after a given period of time. You can set the period of time from
30 minutes to 24 hours.
1
To set the operating time, press the OFF TIMER button one or more times
until the required time is displayed. Possible time is between 0.5 hour and
24 hour inclusive.
2
Press the
(Set/Cancel) button to complete the setting.
Result: ◆ The remaining time is displayed.
◆ Blinking of the timer indicator stops.
◆ The air conditioner will switch off automatically when the
counter displayed on the remote control reaches the set time
and disappears the Off timer setting.
Example If you would like to turn the air conditioner on after 2 hours
and to operate it for 2 hours:
1. Press the ON TIMER button until ‘2.0 Hr’ is displayed.
2. Press the (Set/Cancel) button.
3. Press the OFF TIMER button until ‘4.0 Hr’ is displayed.
4. Press the (Set/Cancel) button.
Note
You can see or change the setting mode and/or the temperature
by pressing the MODE button or the TEMPERATURE buttons
after setting the Off timer.
To Cancel the Off Timer
1
To cancel the Off Timer, press the OFF TIMER button one or more times
until the timer setting disappears.
2
Press the
(Set/Cancel) button.
Note
If you want to turn off the air conditioner before the timer reaches
the setting time, press the
(ON/OFF) button.
E-17
Setting the Sleep Timer
The Sleep Timer can be used when you are cooling your room to
switch the air conditioner off automatically after a period of six hours.
Note
If you wish to switch the unit off at a specific time, refer to
page 17.
1
2
Make sure that you have selected either COOL mode.
Press the
button one or more times until
appears on the
remote control.
Result: ◆ The indoor unit beeps.
◆ The air conditioner will be controlled as indicated in the
illustrations below.
Cooling The desired temperature is
increased by 2°F/1°C every
hour.
When it has been increased
by 4°F/2°C (after two hours),
the temperature is maintained
for four hours.
To Cancel the Sleep Timer
If you no longer wish to use the Sleep Timer that you have set, you
can cancel it at any time.
Press the
Result:
button.
◆
◆
◆
The indoor unit beeps.
The
The air conditioner operates normally.
is no longer displayed.
E-18
Operating Recommendations
Here are a few recommendations that you should follow when using
your air conditioner.
Topic
Recommendation
Power failure
If a power failure occurs when the air
conditioner is operating, the unit is switched off.
When the power returns, you must press the
(ON/OFF) button to restart it.
E-19
Temperature and Humidity Ranges
The following table indicates the temperature and humidity ranges
within which the air conditioner can be used.
If the air conditioner is used at... Then...
High temperatures
The automatic protection feature may
be triggered and the air conditioner
stopped.
Low temperatures
A water leak or some other malfunction
may occur if the heat exchanger
freezes.
High humidity levels
Water may condense on and drip
from the surface of the indoor unit if it
is used for long periods.
Mode
Outdoor Temperature
Indoor Temperature Indoor Humidity
Cooling
70°F to 109°F approx.
65°F to 90°F approx.
21°C to 43°C approx.
18°C to 32°C approx. 80% or less
Drying
65°F to 109°F approx.
65°F to 90°F approx.
18°C to 43°C approx.
18°C to 32°C approx.
-
◆◆ If the cooling operation is used at over 92°F/33°C(indoor temperature)
then, it does not cool as its full capacity.
E-20
Cleaning Your Air Conditioner
To get the best possible use out of your air conditioner, you must
clean it regularly to remove the dust that accumulates on the air filter.
Before cleaning your air conditioner, ensure that you
have switched off the breaker used for the unit.
IMPORTANT
1
2
Open the front grille by lifting the tabs on the lower right and left sides of
the indoor unit.
Disassemble the front grille by pulling it forwards.
3
4
5
Hold the edge of the air filter under the front grille and pull to release them.
Remove all dust on the air filters with a vacuum cleaner or brush.
Clean the front panel with a damp cloth and mild detergent
(do NOT use benzene, solvents or other chemicals).
6
Reassemble the air filters and the front grille.
Note
◆◆ If you have not used the air conditioner for a long period
of time, set the fan going for three to four hours to dry
the inside of the air conditioner thoroughly.
E-21
Solving Common Problems
Before contacting the after-sales service, perform the following simple checks.
They may save you the time and expense of an unnecessary call.
Problem
Explanation/Solution
The air conditioner does not
operate at all
◆ Check that the breaker used for the air conditioner is switched on.
◆ Check that the 5 Way indicator on the indoor unit is on;
if necessary press the
(On/Off) button on the remote control.
◆ Check whether the TIMER indicator on the indoor unit is switched on.
If so:
- Wait until the switch-on time is reached and the air conditioner starts
up automatically
- Cancel the timer (see pages 16 and 17 for further details)
The air conditioner does not
operate with the remote control
◆ Check that there are no obstacles between you and the indoor unit.
◆ Check the remote control batteries.
◆ Check that you are close enough to the indoor unit
(seven metres/yards/23ft. or less).
No beep is heard when you press
◆ Check that you are pointing the remote control at the remote control
sensor in the right of the indoor unit.
the
(On/Off) on the remote
control
◆ Replace the remote control batteries if necessary.
The air conditioner does not cool
◆ Check that the correct operating mode has been selected
(AUTO, COOL).
◆ The room temperature may be too low or too high.
◆ Dust may be blocking the air filter guard; refer to page 21 for cleaning
instructions.
◆ Check that there is no obstacle in front of the outdoor unit.
The fan speed does not change
when you press the FAN button
◆ Check that the operating mode is set to COOL or FAN ;
in the AUTO mode, the fan speed changes automatically and in the
DRY mode, it is set to AUTO.
The air flow direction does not
change when you press the
SWING button
◆ Check that the air conditioner has been switched on; if necessary,
press the
(On/Off) button on the remote control.
The timer is not correctly triggered
◆ Check that the timer has been programmed correctly; see pages 16
and 17.
Odours are permeated in the room ◆ Air the room.
during air conditioning
E-22
Installing a Filter (Option)
The air conditioner can be fitted with a deodorizing and Bio-Pure
filter to remove minute dust particles or odours. The service life of
the filter is approximately three months depending on the time
during which the air conditioner is used.
1
Remove the vinyl packing from the filter.
Note
Do not remove the packing from a deodorizing filter until you
wish to use the filter, as it will lose its properties.
Deodorizing
filter
2
3
Insert the filter in the filter holder and press the three insert tabs until
you hear a click.
Bio-Pure Filter
Open the front grille by pulling on the tabs on the lower right and left
sides of the indoor unit.
4
Take out the existing filter and replace it with the new one.
E-23
Technical Specifications
Indoor unit Outdoor unit Indoor unit Outdoor unit
MODEL
AM18B1C09 UM18B1C2
2 Comp + 2 Room
AM26B1C13 UM26B1C2
2 Comp + 2 Room
Type
Btu/h
Capacity Cooling
Performance
Ratings
A/B-Unit : 9000
10.0
A/B-Unit : 12500
10.0
SEER
Pts/h
CFM
dB
Moisture Removal
Air FLOW(Cooling, HIGH)
Sound Rating-Outdoor
The number of operation
Power source
3
-
4
-
255
-
-
300
-
-
57
60
Electrical
Data
1 Unit operation 2 Unit operation 1 Unit operation 2 Unit operation
208-230V~,60Hz
208-230V~,60Hz
A
Min.Ampacity
4.3
990
8.4
6.1
11.4
2550
B-Unit
W
Cooling Watts
1920
1360
B-Unit
A-Unit
A-Unit
Refrigeration Indoor unit
Lines
Flare
Flare
6.35 (1/4)
Connections
mm(in)
mm(in)
m(ft)
6.35 (1/4)
Liquid Line O. D.
9.52 (3/8)
12.70 (1/2)
Suction Line O.D.
Factory Pre-charge
Max. Line length
1
1
5.0 (
)
)
5.0 (
)
)
16 2
16 2
1
1
15.0 (
15.0 (
m(ft)
49 4
49 4
7.0 (23)
7.0 (23)
Max. Height Difference
m(ft)
790 x 245 x 165 880 x 638 x 310 790 x 245 x 165 1000 x 790 x 310
Dimensions
& Weight
mm(in)
Ibs
W X H X D
Net Weight
1
1
1
1
1 x
x
1 x 1 x
)
1 x 1 x 1 ) ( 1 x 1 x
)
(
(
(
31 8 92 62 ) 34 2 258 12 4 31 8 92 62 39 2 31 12 4
8
17
132.3
17
152.1
◆◆Standard rating conditions Cooling
Indoor
Outdoor
DB
80
WB
67
DB
WB
75
95
°F
26.7
19.4
35.0
23.9
°C
E-24
Indoor unit
Indoor unit
AM27B1C13
Outdoor unit
MODEL
AM27B1C07
UM27B1C3
2 Comp + 3 Room
Type
Btu/h
Performance Capacity Cooling
A-Unit : 13000, B/C-Unit : 7000
10.0
Ratings
SEER
Pts/h
CFM
dB
Moisture Removal
2.5
4
-
-
Air FLOW(Cooling, HIGH)
220
300
Sound Rating-Outdoor
The number of operation
Power source
-
-
62
1 Unit operation
2 Unit operation
3 Unit operation
Electrical
Data
208-230V~,60Hz
A
Min.Ampacity
A : 6.0, B(C) : 5.8 A+B(C) : 11.0, B+C : 6.2
A+B+C : 11.6
A+B+C : 2580
C-Unit
W
Cooling Watts
A+B(C) : 2450, B+C : 1380
B-Unit
A : 1350, B(C) : 1300
A-Unit
Refrigeration
Lines
Indoor unit
Flare
Connections
mm(in)
mm(in)
m(ft)
6.35 (1/4)
Liquid Line O. D.
Suction Line O.D.
Factory Pre-charge
Max. Line length
Max. Height Difference
12.70(1/2)
9.52 (3/8)
1
5.0 (
)
16 2
1
15.0 (
)
m(ft)
49 4
7.0 (23)
m(ft)
790 x 245 x 165
1000 x 790 x 310
Dimensions
& Weight
mm(in)
Ibs
W X H X D
Net Weight
1
1
1 x 1 x
(
1 x 1 x
)
(
31 8 92 62 )
39 2 31 12 4
8
17
154.3
E-25
|