Precisionaire Rigid Air Merv 10 14 User Manual

Rigid-Air  
Spun Glass or Synthetic Media Rigid Filter  
Bulletin PB1001-1106  
General  
The headered version should be selected for use  
with the hardware listed. If the filter is to be installed  
so that it protrudes upstream of the holding frame,  
the box style filter is required.  
Rigid-Air extended media surface rigid filters are  
designed for use in most commercial or industrial  
HVAC systems where medium to high efficiency  
filtration is required.  
Physical Data  
They feature your selection of media backed with  
expanded metal and pleated. The pleats are held  
in place by rigid pleat separators, available in either  
plastic or metal styles on 12"depth filters. 6" depth  
filters feature rugged fiberboard separators. Rigid-  
Air is available in two media types: lofted fiberglass  
and micro-fine synthetic with average efficiency  
ranges of 50-55%, 60-65%, 80-85% and 90-95%  
perASHRAE Standard 52.1 and MERV 10-14 per  
ASHRAE Standard 52.2.  
Frame: 24 ga. corrosion-resistant steel  
doubleturned flange makes a stronger frame.  
Media: Lofted fiberglass or micro-fine synthetic.  
Media Supports: Expanded metal grid with metal  
or plastic pleat separator.  
Face Grid: Horizontal and diagonal metal supports.  
Header: 13/16" wide 26 ga. corrosion-resistant  
steel.  
Operating Limits: 180° F 100% RH%.  
These filters are especially suitable for variable air  
volume systems. Operating face velocity ranges  
are from 0 to 375 fpm for 6" deep filters, and from  
0 to 675 fpm for 12" deep filters. Two frame styles  
are available: a single header model and a box type  
without header. Rigid-Air filters are UL900 Class 2  
listed. Optional Class 1 listed are available with  
metal inserts and fiberglass media.  
Actual Header or Box Filter Face Size: Nominal  
size less 5/8" (e.g., a nominal 24" x 24" filter is  
actually 23 3/8" x 23 3/8").  
Actual Depth: 5-7/8" or 11-1/2".  
Installation Considerations  
Rigid-Air filters may be installed in Astr Holding  
Frames, K-Trac Filter Framing Modules, Sureseal  
Side Access Housings or in similar existing  
hardware.  
Important Features  
• Ecologically advanced filtration medium made  
entirely from recycled materials.  
• Rugged corrosion-resistant steel casing minimizes  
damage during shipping and handling.  
• Lofted fiberglass micro-fine or synthetic media is  
held in position by upstream and downstream  
plastic or metal pleat supports.  
• Units are available with or without header.  
• Filters are completely rigid.  
• MERV 10-14  
Flanders PrecisionAire ~ Foremost in Air Filtration  
Toll Free: 1-800-637-2803  
1
Corrosion Resistant Steel Frame  
Double Turned flange  
for a stronger frame.  
5-7/8" or 11-1/2"  
depths  
Choice of media  
Lofted fiberglass or  
micro-fine synthetic  
Available with or  
without header  
Class 1 available  
with glass media  
and metal fingers.  
Diagonal support  
prevent racking.  
Robust Media Support  
Expanded metal pleat  
backng and choice of metal  
or plastic pleat supports.  
Rigid-Air Box Type Filter  
With Metal Pleat Separators  
Rigid-Air Filter with Header and  
Plastic Pleat Separators  
Flanders PrecisionAire ~ Foremost in Air Filtration  
Toll Free: 1-800-637-2803  
3
Application Guidelines  
Hospital Applications  
Rigid-Air filters may be used wherever job  
requirements and available space will  
accommodate 6" or 12" deep filters. Rigid-Air filters  
should be selected using 24" x 24" and 24" x 12"  
face sizes. This allows for 12" increments in height  
and width of the filter bank and insures that  
replacement cartridges will be readily available.  
Rigid-Air filters may be used on the downstream  
side of the supply fan in hospitals if they are far  
enough from the fan so that the high fan discharge  
velocity will not affect them. Rigid-Air rigid filters can  
withstand adverse air flow conditions better than  
bag filters and are the preferred selection for these  
applications.  
Rigid-Air filters should be installed with pleats vertical  
wherever possible. It is permissible to install 24" x  
12" face size cartridges with pleats horizontal if  
necessary to meet the size requirements of the filter  
bank.  
Gasketed Headers  
Rigid-Air headered filters installed in Flanders K-  
Trac Filter Framing Modules or Sureseal Side  
Access Housings require gaskets on opposite  
header sides to prevent air bypass.  
VAV Systems  
To specify headered version Rigid-Air filters with  
gasketed headers, add suffix “SA” (side access),  
“GU” (upstream), “GD” (downstream) and “GS”  
(sides) to the model number.  
Filter banks should be sized so that the maximum  
rated flow at design conditions falls within the  
published recommended velocities. Rigid-Air filters  
may be applied at any capacity between zero flow  
and cataloged capacities.  
Guide Specifications  
1.0 General  
2.4 The filter pack shall be sealed into a 24 ga.  
corrosion-resistant steel casing with metal or  
plastic pleat separators on the upstream and  
downstream sides to maintain pleat  
configuration.  
1.1 Medium and high efficiency self-supporting filters  
shall be Rigid-Air lofted fiberglass or micro-fine  
synthetic media rigid filters as manufactured by  
Flanders Precisionaire.  
1.2 Filter sizes, efficiencies and capacities shall be  
as scheduled on the drawings.  
3.0 Performance  
3.1 Initial and final resistances shall not exceed the  
scheduled values.  
2.0 Filter Construction  
2.1 Filters shall be constructed of lofted micro-fine  
fiberglass or micro-fine synthetic media  
laminated to a non-woven backing, bonded to  
an expanded metal wire grid and pleated to form  
the filter pack.  
3.2 Media area must equal or exceed that of the  
specified filter.  
3.3 The average efficiency shall be as determined  
by the ASHRAE Standard 52.1 test methods.  
3.4 The Filter shall meet MERV 10-14 as determined  
by ASHRAE Standard 52.2 test standards.  
2.2 The filter pack shall be strengthened on the air  
entering and air exiting sides with horizontal and  
diagonal metal support members.  
3.5 The manufacturer shall guarantee performance  
as stated in its literature within tolerances as  
outlined is Section 7.4 of ARI Standard 850.  
2.3 The enclosing frame shall be assembled in a  
rigid manner and shall incorporate a header on  
the air entering side if required by the application.  
3.6 Filters to be UL 900 Class 2 or 1 listed.  
Representative  
Flanders ~ PrecisionAire  
Foremost inAir Filtration  
Toll Free 1-800-637-2803  
:

Panasonic Kx Tg8232 User Manual
Ricoh Mp C7500 User Manual
Samsung Aw07l1 Series User Manual
Sanyo Twicell Hr Aau User Manual
Schumacher Sc 2500a User Manual
Sharp Af R80ex User Manual
Sharp Fzr65hfu Plasmacluster Air Purifier Replacement Filter Set 74000661776 User Manual
Simplicity Manufacturing Tp 400 2416 00 At Sma User Manual
Stiga Multiclip 50 Euro User Manual
Technics 4510 User Manual