CS-XE9CKR CU-XE9CKR / CS-XE12CKR CU-XE12CKR
9 Operating Instructions
PRODUCT OVERVIEW
1
Y our device can...
Air intake
Cooling
Heating Dehumidifying
Air Circulation
1.1
Outdoor Unit
Air outlet
Oxygen tube & piping, connecting cable
Filters under front panel, see page 4
Indoor Unit
1.2
Indicator & Auto operation button
Direction louver
Ioniz er
DO NOT TOUCH
Fluorescent lights may interfere with signal transmission
Under front panel
!
1
2
Open front panel
If Remote Control malfunctions / is misplaced...
Remote Control
1.3
Press to START
> >
O
N
see page
see page
Switch OFF/ON of the device
O
F
F
AUTO-Mode only
Set TEMPERATURE
53
54
54
53
TEMP
2
Activate
«
»
Activate
«
OXYGEN
»
54
53
54
54
57
Press again to STOP > >
3
MODE
Select air flow direction
Select MODE
QUIET
FAN
Activate
«
QUIET
»
Select Fan Speed 54
Set CLOCK 56
F
AN
SPEED
S
E
T
TIMER functions
C
A
N
C
E
L
Check malfunction code
Open
Memory reset!
52
CS-XE9CKR CU-XE9CKR / CS-XE12CKR CU-XE12CKR
Press button
AIR SWING
AIR SWING
Vertical direction
Horizontal direction
Fan Speed (air volume)
Air Flow
G Air still cold
G Air heated
Direction / volume
Select automatic / manual
Select
ON
OFF
ON
Timer
OFF
Timer
ON/OFF Timers:
Active every day
ON & OFF
Timer
Set time
Confirm
or
Set time
Confirm
or
Set time
Confirm
Cancel
TIMER Operation
Current time OK? –> Setting: page 56
Start before «ON» time
For your comfort
Max 35 Min
Provide quiet operation
Air flow sound
Air flow sound will reduce during operation
QUIET Operation
ON
OF F
Activate / Deactivate
Produce negative ion for fresh air
Air-conditioner
ON
OF F
Still Blinking - Call
ON
OF F
Activate / Deactivate
Provide negative ion
during operation
Provide negative ion
with FAN operation
If Blinking
Service
press twice
Oxygen = 21%
Oxygen Enrich Air
Air-conditioner
~
Normal Air
Oxygen 30%
OXYGEN Operation
ON
OF F
ON
OF F
Activate / Deactivate
Enriches oxygen content
during operation
Enriches oxygen with
FAN operation
Oxygen enrichment membrane
54
CS-XE9CKR CU-XE9CKR / CS-XE12CKR CU-XE12CKR
CARE & CLEANING
Soaps Neutral household
Benzine / Thinner Scouring powder
detergents
Wipe gently
( ~ pH7 )
Filters
Indoor unit
*
Filter cleaning see below
3
3 Release holder from rear side
2 Insert holder
Dry Cloth
4
Front panel
1
2
Remove
slowly
1 Slide in
4
Max.
20°
Max.
20°
Decorative Panel
Remove
Beware of dropping
Wash + Dry
Insert decorative panel
Reinstall
Ionizer
*
?
every 6
months
Part No : CZ-SF70P
REPLACE every 3 Damaged –> replace!
years!
Purifying filter
Vacuum
refresh
Clean with
Open manually
cotton bud
Remove
Reinstall
every 6 months
Part No : CWD001053
<<FRONT>>
Reinstall
Air filters
Part No : CWD001054
Remove
Vacuum
Wash
Dry
Damaged –> replace!
every 2 weeks
?
*
“Catechin” filter
DIRTY FILTERS cause: unpurified air, low cooling/heating capacity, more unpleasant smells, higher energy consumption!
!
HELPFUL INFORMATION
Thunder / Lightning
Automatic Operation
Built-in surge protection, BUT UNPLUG in case of very strong lightning!
If remote control malfunctions / is misplaced
see page 52
AUTO
Save cost
~ -10%
Use....
Power Failure
When power resume...
Close
*
*
Better
Vacuum
*
*
performance
Random restart automatically
COOL + (1°C)
HEAT - (2°C)
3 - 4 Min.
MODE
Restored
Deleted -> set again!
TIMER
see page 54
QUIET!
TIMER!
55
CS-XE9CKR CU-XE9CKR / CS-XE12CKR CU-XE12CKR
Press button
Plug/breaker
PREPARATIONS
Installation: see enclosed installation instruction!
refer page 59
Indoor unit
Place PURIFYING filter
Place AIR filters
CLOSE front panel
Plug in
OPEN front panel
Remove AIR filters
Year
Use
~1
–
+
Check
Insert batteries /
Set clock
Same type! Rechargeable
Open / remove
Insert batteries / close
Press
Set time
Set current time immediately
Confirm
–
Batteries
2.
OK?
~
~
8˚C (COOL)
14˚C (HEAT)
~15
Min.
Pre-season
inspection
Fans obstructed?
START cooling or heating
Check
Check performance
Call Service
1.
2-3[h]
For extended
non-operation
Unplug
dry internal parts
Remove batteries
START
OFF
After several seasons and due to operational conditions, performance may be reduced by dust or there may be
unpleasant smells.
Recommended
Inspections
Consult an authorized distributor for inspection!
56
CS-XE9CKR CU-XE9CKR / CS-XE12CKR CU-XE12CKR
TROUBLESHOOTING
No problem
In case of...
OK?
3 Caused by refrigerant flow inside
3 Condensation effect due to cooling
3 Condensed moisture due to cooling
1 It sounds like water flowing...
2 Mist seems to emerge from the indoor unit
3 Outdoor unit emits water/steam
4 Delayed air discharging
!
• Abnormal noise during operation
• Water/foreign particles have entered the Remote Control
• Water leak from Indoor unit
3 At COOL, SOFT DRY (Auto Fan Speed): Prevent odours
from blowing out
• Switches/buttons do not operate properly
• Circuit breaker switches off frequently
• Power plug/cord become unnaturally warm
• «TIMER» flashes
3 At HEAT (POWER LED flashes): Prevent cold air from
blowing out
Function stops suddenly
3 At COOL, SOFT DRY (Auto Fan Speed): Function
interruptions to the internal temp. measurement
5
3 At HEAT (POWER LED flashes): Iced up outer device is
defrosted (approx. 10min.)
1. press
5 sec.
1
F
A
2
O
N
S
E
O
F
F
3 Oxygen brought in from the outside air may contain odour.
Remove source of odour around the outdoor unit.
6 Smell during oxygen operation
C
T
A
N
IM
ER
C
E2. search code
ꢀ
C
H
E
C
K
R
E
S
E
T
C
L
O
C
K
7 Soft splashing sound from indoor unit during oxygen operation
3 Sound emitted by high humidity airflow from oxygen tube
if 4x beep
=Code
(H23/H26/H27/H28)
*Emergency operation (limited function)
3 Sound increased cause by oxygen operation
8 Slight increase in sound level from outdoor unit
TURN OFF / UNPLUG
3 Circuit breaker tripped?
3 Power plug OK?
3 TIMER used correctly?
1 No Operation
CALL authorized distributor
2 Remote control/display doesn’t work
*1. Press MODE - 2. Select COOL/HEAT - 3. Press OFF/ON
3 Batteries empty?
3 Batteries correctly inserted? See page 56
3 Front grille/panel closed properly?
3 Windows/doors closed?
3 Installation work slanted?
3 Noise too loud
Cooling/heating efficiency low
3 Temperature set correctly?
3 Filters cleaned/replaced?
4
3 Outdoor unit obstructed?
3 Intake/outlet ventilators obstructed?
57
CS-XE9CKR CU-XE9CKR / CS-XE12CKR CU-XE12CKR
SAFETY PRECAUTIONS
Before operating, read the safety precautions thoroughly!
Operation
EMERGENCY!
NEVER use the plug to switch on/off
Immediately isolate from the mains supply (e.g. if there is a smell of burning)
Use only for...
Do NOT stay long in the stream of cold air
Cooling
Air circulation
NEVER use this unit for purposes other than those listed in these
Operating Instructions. In particular, do not use it for the
preservation of food.
Heating
Do NOT operate with wet hands
Dehumidifying
Ventilate the room periodically
Installation
Engage dealer/specialist
NEVER install, remove or reinstall yourself
NOT in potentially explosive atmosphere
NEVER modify / damage mains cables / connectors
Do NOT pull out the plug by the cable
Connect drain hose properly
Mains connection
Engage dealer/specialist for mains connection including...
Place nothing on the unit -> covered openings may cause overheating
Used connectors/breakers easy reachable!
NEVER shared
Plug in properly
Connect protective earth!
Do NOT insert finger or other objects into the unit! -> especially dangerous for children!
Australia (AS) Standard
The appliance is not intended for use by young children or infirm person without supervision.
Young children should be supervised to ensure that they do not play with the appliance.
Unused for a long time? –> OFF/unplug
United Kingdom (GB) Standard
Replacement or installation of power plugs shall be performed by authorized/qualified personnel
only. The wires in this mains lead are coloured in accordance with the following code:
If the supply cord is damaged or needed to be replaced, it must be replaced by the manufacturer or its
service agent or a similarly qualified person in order to avoid a hazard
58
CS-XE9CKR CU-XE9CKR / CS-XE12CKR CU-XE12CKR
SAFETY PRECAUTIONS & FEATURES
refer page
Defects
TEMP
52
OFF/ON
Luminous buttons: convenient in the dark!
2
Defect/suspicion of defect? -> Attend defects before use!
Do NOT repair by yourself
53
54
Automatic Operation: indoor temp. is gauged to select the optimum mode
Ionizer Mode: produce negative ion for fresh air
AUTO
Engage dealer / specialist
54
Cleaning
Oxygen Mode: enriches oxygen content in fresh air
54
OFF and unplug (connector or breaker)
Quiet Mode: to provide quiet operation
55
Do NOT wash!
Auto Restart Control: after power failure, restart automatically when power resume
Removable Front Panel: for quick and easy cleaning, washable
Decorative Panel: for quick and easy cleaning, washable
55
Waste disposal
Uninstalling and disposal of the unit ONLY by dealer / specialist
55
Packaging recyclable
55/56
Catechin Filter: Trapping dust, tobacco, smoke/tiny particles, it inhibits the growth of
bacteria/viruses
Environmental friendly (Refrigerant R410A model): Zero ozone depleting and low
global warming potential
Indoor Unit
Temperature
Wet Bulb
Outdoor Unit
Dry Bulb
min max
min max
11 23
11 26
16 32
Cooling
Heating
16 43
Operational Condition
-
-
16 30
-5 24
[°C]
-6 18
59
|