REGULATORY INFORMATION
■ Operation Condition
The appliance is not intended for use by young children or the infirm person without supervision.
Young children should be supervised to ensure that they do not play with the appliance.
Use this air conditioner under the
following temperature range.
Indoor
Temperature (°C)
Environmental Reeqquuiirreemmeennttss
*DBT *WBT
Maximum
Minimum
Maximum
Minimum
32
16
30
16
23
11
–
COOLING
HEATING
Battery Disposal
The batteries must be recycled or disposed of properly.
–
Outdoor
Temperature (°C)
Maximum
End-oof-Liffe Disspposal
*DBT *WBT
43
16
24
-5
26
11
18
-6
COOLING
Minimum
Maximum
Minimum
HEATING
“Instructions for end-user” for air conditioners:
*DBT: Dry bulb temperature
*WBT: Wet bulb temperature
Information on Disposal in other countries outside the European Union
This symbol is only valid in the European Union. If you wish to discard this product, please contact
your installer, dealer or local authority and ask for the correct method of disposal.
Note:
The illustrations in this manual
Replacement or installation of power plugs shall be performed by authorized/qualified
personnel only.The wires in this mains lead are coloured in accordance with the
following code:
are for explanation purposes only and
may differ from the actual unit. It is
subjected to change without notice for
future improvement.
Wiring colour may vary depending on a country wiring code’s standard.
3
PRODUCT OVERVIEW
■
About
Remote Control Preparation
Air intake
Indoor Unit
1. Pull out
the cover.
Supersonic air
purifying device
Front panel
Auto OFF/ON
button
2. Insert AAA or R03
batteries.
3. Close the cover.
4. Press CLOCK.
TIMER
ON
Receiver
5. Press to
set time.
SET
3
Air filter
1
2
OFF
CANCEL
SET
RESET
CLOCK
Indicator
Airflow direction louver
6. Press again.
• Timer operation will be based
on current time set.
Discharged air
• The batteries can be used for
approximately 1 year.
Outdoor Unit
Air inlet (rear)
Remote Control Signal
• Make sure it is not obstructed.
• Maximum distances: 10m
Air inlet (side)
• Certain fluorescent lights may
interfere signal transmission.
Please consult your nearest dealer.
Air outlet
Auto OFF/ON Button
Remote Control
Transmitter
Action
Press once.
Mode
Automatic
Press and hold until
you hear one beep,
then release.
Cooling
LCD display
Operation mode
Off/On
• To turn off, press the AUTO OFF/
ON button again.
Temperature setting
Fan speed selection
Quiet operation
• To switch the remote control signal
receiving sound off or on.
Powerful operation
Airflow direction
adjustment
1. Press until a single beep sound
is heard and release.
2. Press again until a double beep
sound is heard and release.
3. Press to switch the sound on or
off.
Timer setting
Clock setting
(Long beep - OFF; short beep
- ON)
* Press normal operation, the
buttons is not in use.
* Press button to restore the remote control’s default setting.
RESET
4
AUTO, HEAT, COOL, DRY
■ Operation Details
AUTO - Automatic Operation
• Unit selects the operation mode
according to the room temperature.
• Once the operation mode is
selected, the unit will operate at
the standard setting temperature
as shown:
Standard
setting
temperature
Room
temperature
Operation
mode
23°C &
above
FAN
AUTO
HEAT
COOL
DRY
Cool
Dry
25°C
22°C
SPEED
AIR
SWING
2
Below
23°C
1
OFF
Select the
desired
Below
20°C
OFF
ON
Heat
or
21°C
Start the
operation.
TIMER
TIMER
OFF/ON
• Press
to change the
operation.
MODE
temperature setting to “HI” or “LO”
as shown:
QUIET
FAN SPEED
AIR SWING
Operation mode
HI
LO
TEMP
POWERFUL
Cool
Dry
27°C
24°C
23°C
23°C
20°C
19°C
TIMER
ON
SET
Heat
3
HEAT - Heating Operation
1
2
3
• In heating mode, it takes a while
for the unit to warm up. The
power indicator blinks during this
operation.
Set the
OFF
SET
CANCEL
RESET
temperature.
CLOCK
• The range of temperature can be
selected from 16°C ~ 30°C.
COOL - Cooling Operation
• Enjoy cool air at your desired
temperature.
• The range of temperature can be
selected from 16°C ~ 30°C.
DRY - Soft Dry Operation
• Keep your environment
dehumidified by running cooling
operation at a low fan speed.
• The range of temperature can be
selected from 16°C ~ 30°C.
● Supersonic air purifying device (super alleru-buster) operates
automatically once the unit is switched on.
POWERFUL
■ Hint
●
and QUIET operations are available in all modes.
• A temperature setting 1°C higher
in cooling operation or 2°C lower in
heating operation than the desired
temperature equates to a 10%
power saving.
OFF/ON
● Press
again to stop the operation.
Troubleshooting
● Mist emerges from indoor unit.
► Condensation effect due to cooling process.
●
► Ensure temperature is set correctly.
Heating/Cooling operation does not work.
► Make sure windows and doors are closed.
► Make sure filters are cleaned and replaced.
► Make sure inlet and outlet vents are cleared.
● Water flowing sound during operations.
► Cause by refrigerant flow inside the unit.
● The power indicator blinks during the operation and
► The unit is in defrost mode, and the melted frost is drained from the
the indoor fan is stopped.
outdoor unit.
5
FAN SPEED, AIR SWING
■ Operation Details
• There are 3 fan speeds, as well as
automatic*.
* For automatic fan speed,
the speed of the indoor fan
is automatically adjusted
according to the operation.
Select fan
speed.
FAN
AUTO
HEAT
COOL
DRY
• Keeps the room ventilated.
SPEED
AIR
• There are 5 options for vertical
airflow direction.
SWING
OFF
• If automatic vertical airflow
OFF
ON
direction has been set, the louvers
swing up and down automatically.
TIMER
TIMER
OFF/ON
• For HEATING operation, the air
blows horizontally for a while, then
starts to blow downwards.
MODE
QUIET
AIR SWING
• Do not adjust the vertical airflow
direction louver by hand.
• Horizontal airflow direction louver
is manually adjustable.
TEMP
POWERFUL
TIMER
ON
SET
1
2
3
OFF
SET
CANCEL
RESET
CLOCK
Adjust the
airflow
direction louver.
Troubleshooting
● The room has a peculiar odour.
► This may be a damp smell emitted by the wall, carpet, furniture or
clothing.
● Indoor fan stops occasionally during automatic fan
► This helps to remove the surrounding odours.
speed setting.
● Indoor fan stops occasionally during heating
► To avoid unintended cooling effect.
operation.
6
POWERFUL, QUIET
■ Operation Details
• To reach the desired set
temperature quickly. It will
operates for 15 minutes and
returns to the desired setting.
• To provide a quiet surrounding.
FAN
AUTO
HEAT
COOL
DRY
SPEED
AIR
SWING
Enables
quiet
operation.
OFF
OFF
ON
■ Hint
TIMER
TIMER
• To reduce power consumption
during cooling operation, close the
curtains to prevent the sunlight and
heat from coming in.
OFF/ON
MODE
QUIET
FAN SPEED
AIR SWING
TEMP
POWERFUL
TIMER
ON
SET
1
2
3
Enables
powerful
operation.
OFF
SET
CANCEL
RESET
CLOCK
POWERFUL
QUIET
QUIET
●
●
and
operations could not be activated at the
operations could be cancelled by pressing
same time.
POWERFUL
and
the respective button again.
Troubleshooting
● Noisy during operation.
► The unit may have been installed at an incline, or the front panel is not
closed properly.
► The delay is a protection to the unit’s compressor.
● Operation is delayed a few minutes after restart.
► Condensation or evaporation occurs on pipes.
● Outdoor unit emits water/steam.
7
TIMER
■ Operation Details
• The timer allows you to turn the air
conditioner on or off automatically.
• The unit may start in preliminary
operation before the actual set time
when ON timer has been set.
• The set timer repeats daily once
set.
• If there is a power failure, you can
restore the previous setting (once
power is resumed) by pressing the
button.
2
Set the
desired time.
• If the timer is cancelled, press
to restore the previous setting.
FAN
AUTO
HEAT
COOL
DRY
SPEED
AIR
1
SWING
Select ON or
OFF timer.
OFF
OFF
ON
TIMER
TIMER
■ Hints
• Press and hold the
approximately 5 seconds to set
either 12-hour (am/pm) or 24-hour
time indication.
OFF/ON
MODE
3
for
Confirm the
setting.
QUIET
FAN SPEED
AIR SWING
TEMP
• To dim the indicator display:
POWERFUL
TIMER
ON
SET
1
2
3
Press and hold for
5 seconds.
OFF
SET
CANCEL
RESET
TIMER
ON
SET
3
To cancel, press
the again for
5 seconds.
CLOCK
1
2
OFF
CANCEL
SET
RESET
CLOCK
Cancel the
selected timer.
• To switch the temperature setting
to °C or °F, press and hold
for approximately 10 seconds.
● The timer is valid only when the clock is set correctly.
● You can set your preferred time for ON and OFF timers.
The unit will turn ON or OFF automatically.
● To cancel ON or OFF timer, press
press
or
, then
.
Troubleshooting
● Timer indicator always on.
● Remote control does not work.
● The unit does not work.
► The timer setting repeats daily once set.
► The batteries are inserted incorrectly or need replacing.
► The circuit breaker is tripped or the timer is set incorrectly.
8
CARE & CLEANING
■ Washing Instructions
• Do not use benzene, thinner or
scouring powder.
Switch ooff tthhee ppoowweerr ssuuppppllyy
before cleaning
• Use only soaps ( pH7) or neutral
≃
household detergen.
• Do not use water hotter than 40°C.
FRONT PANEL
Raise and pull to remove.
Wash and dry.
INDOOR UNIT
• Wipe the unit gently with a soft, dry
cloth.
AIR FILTER
AIR FILTER
Vacuum, wash and dry.
• Air filters cleaning is needed every
two weeks.
• Replace any damaged filter.
Part no.: CWD001144
SUPER ALLERU-BUSTER
• It is recommended to clean this
filter every 6 months.
Remove
• Replace the filter every 3 years or
replace any damaged filters.
Part no.: CZ-SA13P
Remove
■ Hints
• Clean the filter regularly for best
performance and to reduce power
consumption.
INDOOR UNIT
Wipe gently.
• Please consult your nearest dealer
for seasonal inspection.
SUPERSOONIC AIR
PURIFYINGG DEVICE
Vacuum the super
alleru-buster filter.
Remove
Vacuum, wash and
dry the frame.
■ For extended non-use
• Activate heating for 2~3 hours to thoroughly dry the unit.
• Turn off the power supply and unplug.
• Remove the remote control batteries.
9
SEASONAL INSPECTION AFTER EXTENDED NON-USE:
• Checking of remote control batteries.
• No obstruction at inlet and outlet vents.
• After 15 minutes of operation, it is normal to have the following temperature difference between inlet and outlet vents:
Cooling: ≥ 8°C
Heating: ≥ 14°C
10
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY and CALL Authorized Distributor under the following conditions:
• Abnormal noise during operation.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
• Water/foreign particles have entered the Remote Control.
• Water leak from Indoor unit.