Operating Instructions
Air Conditioner
Model No.
Indoor Unit
Single Split
Outdoor Unit
CS-E9JKKW-1
CU-E9JKK-1
CS-E12JKKW-1 CU-E12JKK-1
CS-E18JKK-1
CS-E22JKK-1
CU-E18JKK-1
CU-E22JKK-1
Multi Split
Outdoor Unit
CU-2E18JBK-1
Before operating the unit, read these operating
instructions thoroughly and keep them for future
reference.
© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2010.
Unauthorized copying and distribution is a violation
of law.
QUICK GUIDE
F567672
WARNING
CAUTION
POWER SUPPLY
Do not use modified cord,
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene,
thinner or scouring powder.
joint cord, extension cord or
unspecified cord to prevent
overheating and fire.
Do not use for other purpose such as
preservation of food.
Do not share the same power outlet with other
equipment to prevent overheating and fire.
Do not use any combustible equipment in front of
the airflow outlet to avoid fire.
Do not operate with wet hands to prevent electric
shock.
Do not expose yourself directly to cold air for a
long period.
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
Do not sit or step on the unit, you may
fall down accidentally.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or fire.
Do not touch the sharp aluminium fin,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the floor. After waxing, aerate the room properly
before operating the unit.
This equipment must be earthed to prevent
electrical shock or fire.
Do not install the unit in oily and smoky areas.
Prevent electric shock by switching off the power
supply when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
Ensure drainage pipe is connected properly.
Otherwise, leakage may occur.
Aerate the room regularly.
After long period of use, make sure the
installation rack is not deteriorate to prevent the
unit from falling down.
Stop using the product when any
abnormality/failure occurs and
disconnect the power plug or turn off
the power switch and breaker.
REMOTE CONTROL
Do not use rechargeable (Ni-Cd) batteries.
It may damage the remote control.
(Risk of smoke/fire/electric shock)
• The ELCB trips frequently.
• Burning smell is observed.
• Abnormal noise or vibration of the unit
is observed.
Remove the batteries if the unit is not going to be
used for a long period of time.
New batteries of the same type must be inserted
following the polarity stated to prevent
malfunction of the remote control.
• Water leaks from the indoor unit.
Examples of
• Power cord or plug becomes
abnormally hot.
abnormality/
failure
• Fan speed cannot be controlled.
• The unit stops running immediately
even if it is switched on for operation.
• The fan does not stop even if the
operation is stopped.
Indoor
Unit
Air Inlet
Remote
Control
Air Outlet
Contact immediately your local dealer
for maintenance/repair.
Power
Supply
Air Inlet
Outdoor
Unit
Air Inlet
Air Outlet
3
MULTI AIR CONDITIONER SYSTEM
Multi Split Outdoor Unit
(CU-2E18JBK-1)
DEFINITION
Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit.
INDOOR UNIT
• It is possible to operate the indoor units individually or simultaneously. The operation mode priority is given to the first unit
that turned on.
• During operation, heating and cooling mode could not be activated at the same time for different indoor unit. The power
indicator blinks to indicate the indoor unit is standing by for different operation mode.
Living room
Multi Split Outdoor Unit
Bedroom
POWER SUPPLY
Time Delay Circuit
Models Number
Rated Volts
Breaker
15 Amps
15 Amps
20 Amps
25 Amps
CS-E9JKKW-1 / CU-E9JKK-1
CS-E12JKKW-1 / CU-E12JKK-1
208/230V
Single Split System
Multi Split System
CS-E18JKK-1 / CU-E18JKK-1
CS-E22JKK-1 / CU-E22JKK-1
CS-E9JKKW-1, CS-E9JKKW-1 / CU-2E18JBK-1
CS-E9JKKW-1, CS-E12JKKW-1 / CU-2E18JBK-1
CS-E12JKKW-1, CS-E12JKKW-1 / CU-2E18JBK-1
25 Amps
208/230V
4
INDOOR UNIT
•Switch off the power supply before cleaning.
•Do not touch the aluminium fin, sharp parts may cause injury.
CAUTION
CLEANING INSTRUCTIONS
HINT
• Do not use benzene, thinner or scouring powder.
• Use only soap ( pH7) or neutral household detergent.
• Do not use water hotter than 104°F.
• To ensure optimal performance of the unit, cleaning
maintenance has to be carried out at regular intervals.
Dirty unit may cause a malfunction and you may see
error code “H99”. Please consult authorized dealer.
2
4
1
7
9
3
8
5
6
1
7
INDOOR UNIT
AUTO OFF/ON BUTTON
• Wipe the unit gently with a soft, dry cloth.
• Use when remote control is misplaced or a malfunction
occurs.
2
FRONT PANEL
Action
Mode
Remove Front Panel
Press once.
Auto
• Raise and pull to remove the front panel.
• Wash gently and dry.
Press and hold until 1 beep is heard,
then release.
Press and hold until 1 beep is heard,
then release.
Press again until 2 beeps are heard,
then release.
Cooling
Heating
Close Front Panel
Press the button to turn off.
• Press down both ends of the front panel to close it
securely.
8
AIR PURIFYING FILTER
Vacuum the air purifying filter.
3
4
5
REMOTE CONTROL RECEIVER
ALUMINIUM FIN
• It is recommended to clean the filter every 6 months.
• Replace the filter every 3 years or replace any damaged
HORIZONTAL AIRFLOW DIRECTION LOUVER
filter.
Part no.: CZ-SA20P
E9JKKW-1, E12JKKW-1
• Manually adjustable.
9
AIR FILTERS
• Air filter cleaning is required every two weeks.
• Wash/rinse the filters gently with water to avoid damage
to the filter surface.
E18JKK-1, E22JKK-1
• Do not adjust by hand.
• Dry the filters thoroughly under the shade, away from
fire or direct sunlight.
• Replace any damaged filters.
6
VERTICAL AIRFLOW DIRECTION LOUVER
• Do not adjust by hand.
5
REMOTE CONTROL
4
TO SELECT FAN SPEED (5 OPTIONS)
FAN SPEED
• For AUTO, the indoor fan speed is automatically adjusted
according to the operation mode.
Maximum distances: 26ft
TO ADJUST VERTICAL AIRFLOW DIRECTION
(5 OPTIONS)
5
AIR SWING
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver swing
up/down automatically.
• In HEAT mode, if AUTO is set, the louver fix at
predetermined position.
INDICATOR
POWER
TIMER
(Green)
(Orange)
(Orange)
(Orange)
QUIET
POWERFUL
6
TO ADJUST AIRFLOW DIRECTION (5 OPTIONS)
(PAGE 7)
Press the remote control’s button
AIR SWING
1
TO TURN ON OR OFF THE UNIT
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver swing
left/right and up/down automatically.
• In HEAT mode, if AUTO is set, the horizontal louver fix at
predetermined position. The vertical louver swing left/right
after the temperature rises.
• Please be aware of the OFF indication on the remote
control display to prevent the unit from starting/stopping
improperly.
2
TO SET TEMPERATURE
• Selection range : 60°F ~ 86°F.
• Operating the unit within the recommended temperature
could induce energy saving.
Remote Control display
HEAT mode : 68°F ~ 75°F.
COOL mode : 78°F ~ 82°F.
DRY mode : 2°F ~ 4°F lower than room temperature.
3
TO SELECT OPERATION MODE
AUTO mode - For your convenience
• During operation mode selection the power indicator
blinks.
• Unit selects operation mode every 30 minutes according
to temperature setting, outdoor and room temperature
(For Single Split System).
• Unit selects operation mode every 3 hours according to
temperature setting, outdoor and room temperature (For
Multi Split System).
HEAT mode - To enjoy warm air
• Unit takes a while to warm up. The power indicator blinks
during this operation.
1
3
4
2
5
7
8
COOL mode - To enjoy cool air
• Use curtains to screen off sunlight and outdoor heat to
reduce power consumption during cool mode.
9
10
DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle cooling
operation.
13
12
11
6
E9JKKW-1, E12JKKW-1
7
TO ENJOY QUIET OPERATION
TO SET THE TIMER
• This operation reduces airflow noise.
• To turn ON or OFF the unit at a preset time.
ON
TO REACH TEMPERATURE
QUICKLY
8
1
2
SET
• Single Split System: This operation stops automatically
after 20 minutes.
OFF
• Multi Split System: Press the button again or turn OFF the
unit to stop this operation.
Select ON or
OFF timer
Set the time
Confirm
ON
Press and hold for 5 seconds to dim or restore the
9
OFF
• To cancel ON or OFF timer, press
press CANCEL
or
then
unit’s indicator brightness.
.
Press and hold for approximately 10 seconds to
• When ON Timer is set, the unit may start earlier (up
to 35 minutes) before the actual set time in order to
achieve the desired temperature on time.
10
show temperature setting in °C or °F
Press and hold for approximately 5 seconds to show
12-hour (am/pm) or 24-hour time indication.
• Timer operation is based on the clock set in the
remote control and repeats daily once set. For clock
setting, please refer to Remote Control Preparation at
back cover.
11
12 Press to restore the remote control’s default setting.
13 Not used in normal operations.
NOTES
• If timer is cancelled manually or due to power failure,
you can restore the previous setting (once power is
SET
resumed) by pressing
.
QUIET
POWERFUL
,
• Can be activated in all modes and can be cancelled by
pressing the respective button again.
QUIET
POWERFUL
,
• Cannot be selected at the same time.
6
E18JKK-1, E22JKK-1
7
TROUBLESHOOTING
The following symptoms do not indicate malfunction.
SYMPTOM
CAUSE
Mist emerges from indoor unit.
Water flowing sound during operation.
The room has a peculiar odour.
► • Condensation effect due to cooling process.
► • Refrigerant flow inside the unit.
► • This may be due to damp smell emitted by the wall,
carpet, furniture or clothing.
Indoor fan stops occasionally during automatic fan speed
setting.
► • This helps to remove the surrounding odours.
Airflow continues even after operation has stopped.
► • Extraction of remaining heat from the indoor unit
(maximum 30 seconds).
Operation is delayed a few minutes after restart.
Outdoor unit emits water/steam.
► • The delay is a protection to the unit’s compressor.
► • Condensation or evaporation occurs on pipes.
► • The timer setting repeats daily once set.
Timer indicator is always on.
Power indicator blinks during HEAT mode with no warm air ► • The unit is in defrost mode (and AIR SWING is set to
supply (and louver is closed).
AUTO).
Indoor fan stops occasionally during heating operation.
Power indicator blinks before the unit is switched on.
► • To avoid unintended cooling effect.
► • This is a preliminary step in preparation for the operation
when the ON timer has been set.
Cracking sound during operation.
► • Changes of temperature cause the expansion/contraction
of the unit.
Check the following before calling for servicing.
SYMPTOM
CHECK
Heating/Cooling operation is not working efficiently.
► • Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the filters.
• Clear any obstruction at the air inlet and air outlet vents.
Noisy during operation.
► • Check if the unit has been installed at an incline.
• Close the front panel properly.
Remote control does not work.
(Display is dim or transmission signal is weak.)
► • Insert the batteries correctly.
• Replace weak batteries.
The unit does not work.
► • Check if the circuit breaker is tripped.
• Check if timers have been set.
The unit does not receive the signal from the remote
control.
► • Make sure the receiver not obstructed.
• Certain fluorescent lights may interfere with signal
transmitter. Please consult authorized dealer.
The unit stops and the timer indicator blinks.
Use remote control to retrieve error code.
TIMER
Press for 5
Note:
ON
SET
3
1
3
4
Press until you hear
beep sound, then
write down the error
code.
2
seconds.
• For certain errors, you
may restart the unit for
limited operation with 4
beeps during operation
starts.
1
2
Press for 5
seconds to
quit checking.
OFF
CANCEL
AC
RC
SET CHECK CLOCK
RESET
Turn the unit off and reveal the error code to authorized dealer.
8
INFORMATION
Information for Users on Collection and Disposal of Old Equipment and used Batteries
[Information on Disposal in other Countries
outside the European Union]
Note for the battery symbol (bottom two
symbol examples):
These symbols are only valid in the European
Union. If you wish to discard these items,
please contact your local authorities or dealer
and ask for the correct method of disposal.
This symbol might be used in combination with
a chemical symbol. In this case it complies with
the requirement set by the Directive for the
chemical involved.
Pb
Contact your country hazardous waste disposal hotline.
FOR SEASONAL INSPECTION AFTER EXTENDED
NON-USE
SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then please consult
authorized dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• After 15 minutes of operation, it is normal to have the
following temperature difference between air inlet and air
outlet vents:
Cooling: ≥ 46.4°F
Heating: ≥ 57.2°F
FOR EXTENDED NON-USE
• Activate Heat mode for 2~3 hours to remove moisture left
in the internal parts thoroughly to prevent mould growth.
• Turn off the power supply.
• Remove the remote control batteries.
9
MEMO
MEMO
QUICK GUIDE
Remote Control Preparation
1
2
Pull out
1
2
3
4
5
6
Insert AAA or R03 batteries (can be used ~ 1 year)
3
Close the cover
Press CLOCK
Set time
4
5
6
TIMER
ON
SET
1
2
3
OFF
CANCEL
Confirm
AC
RC
SET CHECK CLOCK
RESET
1
MODE
AUTO HEAT
DRY COOL
AUTO
HEAT
COOL
DRY
FAN
AUTO
HEAT
COOL
DRY
FAN
SPEED
SPEED
AIR
SWING
AIR
Select the desired mode.
SWING
OFF/ON
TEMP
2
OFF/ON
TEMP
1
3
MODE
MODE
FAN SPEED
AIR SWING
FAN SPEED
AIR SWING
2
OFF/ON
Start/stop the operation.
QUIET POWERFUL
QUIET POWERFUL
TIMER
ON
TIMER
ON
SET
3
SET
3
1
2
1
2
OFF
CANCEL
OFF
CANCEL
AC
RC
AC
RC
3
TEMP
SET CHECK CLOCK
RESET
SET CHECK CLOCK
RESET
Select the desired temperature.
E9JKKW-1, E12JKKW-1
E18JKK-1, E22JKK-1
Panasonic Corporation
For enquiries, please call 1-800-851-1235
Printed in Malaysia
OSSC1004-00
F567672
|