Installation Preparation Document (for physical installation of the product only)
Xerox DocuTech 6100/6115/6135
Customer Support
Electrical Requirements
Digital Front End (DFE) Controller Platform:
The Xerox Customer Support Center is available to provide general
information, answer questions, and take service calls. You can reach
the Customer Support Center at the following toll-free phone number:
United States 1-800-821-2797
Your Xerox Analyst will provide fee-based training upon request.
Line Options:
Voltage
Dedicated
110V
Amperage
Cycles
15
Space Requirements
60 Hz
The diagram below is provided as a representation only of the space
envelope required for installation of Xerox equipment. Diagram is a
representation only and not drawn to scale.
15 amp Receptacle Xerox Part No.
20 amp Receptacle Xerox Part No.
600S3704
600S3703
Receptacle NEMA Part No.
Receptacle Diagram
5 - 20R or 5 - 15R
D
E
D o c u T e c h 6 1 x x
or
P
T
H
•
All controller configurations require a 110VAC, 15 Amp
grounded receptacle for the outlet strip that provides receptacles
for the controller and its peripheral devices (monitor, modem,
CDROM drive, and tape drive)
W ID T H
•
•
Adapters that eliminate the ground connection to the outlet can
not be used.
Xerox provides 15 feet of cabling with Teflon coating (Plenum
rated), to connect the controller to the Processor/Finisher.
R ep re s e n ta tio n o n ly .
Note: The 6100, 6115, 6135 are available with and without a stand to
support the controller. If a stand is ordered, it will be positioned to the
left of the printer, within the service space envelope. If no stand is
ordered, the controller will be placed on the floor to the left of the
printer in the service space envelope.
Interposer
Note: The dimensions shown below provide the overall service space
required, including the space to the nearest obstruction. The
dimensions are in inches and are absolute minimums.
Line Options:
Dedicated
Voltage
120
15
Amperage
With stand
Without stand
Cycles
60 Hz
600S3704
5 - 15R
6 feet
Width
Depth
114.0”
Width
Depth
114.0"
Configuration
Receptacle Xerox Part No.
Receptacle NEMA Part No.
Power Cord Length
Receptacle Diagram
6100, 6115, 6135
with interposer, and
Finisher
243.0"
196.0"
240.0”
6100, 6115, 6135
without Interposer,
with Finisher
114.0”
193.0”
114.0"
Electrical Requirements
Installation Considerations
Printer/Finisher/Binder
•
There should be a minimum of 78 inches (1,981mm) clearance
Line Options:
Single
from the floor to the nearest overhead obstruction.
Mobility Assist Device - The optional mobility assist device
reduces the installation clearance required to 30 inches
(760mm) at the processor end of the printer and 15 inches (380
mm) at the finisher end.
•
Source
208/240
50
Voltage
Amperage
•
For proper operation, the printer must be perfectly level. The
floor must be level within 2 degrees in any direction. On floors
less than 2 degrees out of level, installation personnel install a
leveling kit to level the machine.
If the floor is more than 2 degrees out of level, this condition
cannot be corrected by the leveling kit. Another suitable location
must be found for the printer to be installed properly.
A minimum 50-inch clearance of exclusive operator area must
be maintained in front of each component. This space cannot
be shared.
Cycles
60 Hz
Receptacle Xerox Part No.
Receptacle NEMA Part No.
Power Cord Xerox Part No.
600S3779
14-50R
•
•
•
98K19950
117K9940
Receptacle Diagram
A minimum of 36 inches of clearance is required in the back of
each component for general service clearance.
* Dedicated power outlets required. Ensure each power cord has a separate
circuit that cannot be shared with other devices.
*15 ft. power cord(s) are provided, however, the distance from the equipment
to the outlet should not exceed 13.1 ft.
Please ensure electrical, space, and supplies are available prior to equipment delivery.