Xantech Switch HD44C User Manual

INSTALLATION INSTRUCTIONS  
HD44CC5  
High Definition Video Matrix Switcher,  
Coaxial and CAT5  
HD44C  
High Definition Video Matrix Switcher,  
Coaxial Only  
DESCRIPTION  
The HD44CC5 four-source, four-zone high-definition matrix switcher has component video and  
S/PDIF digital audio inputs for each source. All four zone outputs have component video output and  
S/PDIF audio output for economical local distribution up to 250’, as well as a RJ45 output for  
transmission of the video and digital audio signal up to 1000’ to the HDRXSG01 receiver located in  
the zone. Both coaxial component video output and CAT5 output are active simultaneously, making it  
possible to distribute four sources to eight outputs at the same time.  
The HD44C has the same great features as the HD44CC5 without the CAT5 output. The HD44C is  
ideal for installations requiring local switching and distribution up to 250’.  
The HD44CC5 and HD44C unit is expandable up to 16 zones.  
SPECIFICATIONS  
ƒ Size: 17” W x 7 3/8” D x 3 15/16” H  
ƒ Weight: 9.25 lbs (4.2 kilos)  
ƒ Controllable through IR and RS232 commands  
ƒ Bandwidth supports resolutions of 1080p, 1080i, 720p, 480p and 480i.  
ƒ Optional Rack Mount kit available (RM2UKIT)  
ƒ Power supply (120VAC, 0.25A, 50-60Hz)  
ƒ Operates in temperatures up to 55 degrees Celsius.  
08905071A  
- 1 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[3] IR RECEIVER  
The rear panel IR receiver is a 3.5mm Stereo jack that is compatible with all Xantech IR receivers,  
such as the 291-10. Switch 4 must be in the OFF position to use this jack.  
PLUG  
TIP  
RING  
CIRCUIT  
IR SIGNAL  
GROUND  
SLEEVE +12VDC, 25mA  
[4] IR BUS, EMITTER PORT  
The 3.5mm Mono jack is an emitter port. The IR signal is connected to the IR Receiver. A Xantech  
283M emitter can be connected to this port.  
PLUG  
CIRCUIT  
TIP  
IR SIGNAL  
SLEEVE GROUND  
The 2-Pin WECO screw terminal is an IR port. The IR signal is connected to the IR Receiver. The  
WECO screw terminal allows easy installation to a typical Xantech IR connecting block.  
[5] RS232 (SERIAL) COMMANDS  
The RS232 Port is bi-directional. The communication is set to 9600 Baud 8-N-1.  
DB9 CONNECTOR  
CIRCUIT  
TX  
PIN  
2
RX  
3
GND  
5
RS232 COMMAND STRUCTURE  
Where:  
{z#} - Zone Number. Range is 1..4 (1..16 if expanded)  
{s#} - Source Input Number. Range is 1..4  
{0/1} – Either 0 (zero) or 1 (one). 0 – Off, 1 – On.  
REMARKS  
NAME  
Zone Power  
COMMAND  
!{z#}PR{0/1}+  
To turn on Zone 2: !2PR1+  
To turn off Zone 1: !1PR0+  
Zone Power Toggle  
All Zones Off  
!{z#}PT+  
!AO+  
Zone Restore All  
Input (Source) Select !{z#}SS{s#}+  
!RF+  
Restore all the Zone-to-Source routing: !RF+  
To set Zone 1 to Source Input 5: !1SS5+  
08905071A  
- 3 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS232 QUERIES  
NAME  
QUERY  
RESPONSE  
EXAMPLE  
EXPLANATION  
Zone Power  
Input Select  
?{z#}PR+  
?{z#}SS+  
?{z#}PR{0/1}+ ?7PR0+  
Power in zone 7 is OFF.  
Zone 5 is Source 3.  
?{z#}SS{s#}+  
?5SS3+  
[6] AC POWER INPUT  
Standard IEC 3-Conductor AC Line Cord Receptacle for plug-in of a 3-conducator power line cord. Be  
sure to note if the power receptacle is domestic (120VAC type) or international (240VAC type).  
[7] RS232 EXPANSION  
The HD44C and HD44CC5 can be expanded into a larger system. By using any combination of the  
HD44C and HD44CC5 (up to 8 systems), a larger High-Definition distribution system can be created.  
For instance, two HD44C systems can be combined to create a much larger 4 source input to 8 zone  
output. The two HD44C systems must have its own unique address (see ADDRESS (DIP SWITCH)  
section). The included RS232 expansion cable allows a single RS232 control port to be used to  
command the entire system. The expansion cable is connected between the DB9 (5) and 3.5mm  
stereo mini jack (7).  
DB9 MALE  
CIRCUIT  
TX  
3.5MM PLUG  
PIN  
2
3
PLUG  
TIP  
CIRCUIT  
TX  
RX  
RX  
RING  
GND  
5
SLEEVE GND  
[8] ADDRESS (DIP SWITCH)  
Switch 1 & 2: Unit Address (for Expansion mode)  
ADDR  
UNIT 1  
UNIT 2  
UNIT 3  
UNIT 4  
SW 1 SW 2  
ON  
ON  
ON  
OFF  
OFF  
OFF  
ON  
OFF  
Switch 3: ON for firmware write protect  
Switch 4: ON for front panel IR receiver / OFF for rear panel IR receiver  
08905071A  
- 4 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[9] CAT5 ZONE OUTPUT  
Output connection to the HDRXSG01 receiver module. Uses standard CAT5 cable. Be sure to verify  
CAT5 wiring connection is correct before installation.  
[10] COAXIAL ZONE OUTPUT  
Gold-plated RCA jacks for connection to an HD monitor. Color coordinated to match all HD type  
products.  
The CAT5 and coaxial output can be used at the same time.  
IMPORTANT NOTICE  
After connecting the CAT5 cable to the receiver (HDRXSG01), the  
power supply to the receiver should be unplugged for a few seconds  
and then reconnected. This allows the receiver to go through the full  
process of line length and line quality self-calibration.  
As an alternate process to this procedure, the power may be cycled  
off for a few seconds and reapplied to accomplish the same full self-  
calibration process.  
If for some reason the system losses power at the receiving end  
(HDRXSG01), the transmitting end (HD44CC5), or both ends, the full  
self-calibration process will automatically occur.  
08905071A  
- 5 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK INSTALLATION: HD44CC5 and HDRXSG01  
[1] Connect the High-Definition Source to the HD44CC5 or HDTXSG01. Figure 1 below shows a  
HD44CC5 (video matrix transmitter) connected to the HDRXSG01 (receiver).  
[2] Using CAT5 cable, connect the HD44CC5 zone output or the output from the HDTXSG01 to the  
HDRXSG01. Connect power to the HD44CC5 first. Then connect power to the HDRXSG01.  
[3] On the HD44CC5, set the source to zone to enable the HDRXSG01 from the connected High-  
Definition source. See HD44CC5 manual on how to use RS232 and IR RC68+ controls.  
[4] Installation Complete! No adjustments needed!  
08905071A  
- 6 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC68+ (IR) COMMANDS  
The RC68+ should be set to Group Code “C0”.  
ZONE 1  
ZONE 2  
ZONE 3  
ZONE 4  
1
2
Zone Power Toggle  
80  
48  
10  
90  
SRC 1  
00  
SRC 2  
C0  
SRC 3  
50  
SRC 4  
D0  
Zone 1 Source Select  
Zone 2 Source Select  
Zone 3 Source Select  
Zone 4 Source Select  
40  
20  
60  
A0  
E0  
88  
30  
70  
18  
B0  
F0  
98  
ZONE 1  
08  
ZONE 2  
A8  
ZONE 3  
38  
ZONE 4  
B8  
3
4
5
6
Zone Power On  
Zone Power Off  
Zone Power All Off  
Zone Restore All  
28  
E8  
78  
F8  
68  
C8  
08905071A  
- 7 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADVANCE INSTALLATION  
FIGURE 2: Below shows a diagram for a sports bar application. With the equipment rack located near  
or behind the bar area, the coaxial outputs can be used for local HD monitors. The CAT5 outputs can  
be used to deliver HD content to areas such as outdoor patios and pool table recreational areas.  
FIGURE 2  
FIGURE 3: The figure in the next page shows an expanded HD44CC5 system. With two HD44CC5  
devices, HD content can be distributed to 16 displays (8 with CAT5 outputs, 8 with coaxial outputs).  
The included RS232 expansion cable allows a single RS232 control port to be used to command the  
entire system.  
08905071A  
- 8 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIGURE 3  
08905071A  
- 9 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Xantech Corporation  
13100 Telfair Avenue, 2/F  
Sylmar, CA 91342  
Phone: (818) 362-0353, Fax: (818) 362-9506  
Installation Instructions, HD44CC5, HD44C © 2007 Xantech Corporation  
This document is copyright protected. No part of this manual may be copied or reproduced in any form without prior  
written consent from Xantech Corporation.  
Xantech Corporation shall not be liable for operational, technical, or editorial errors/omissions made in this document.  
Document Number 08905071A  
08905071A  
- 10 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Westinghouse Mixer WST2011ZE User Manual
Whirlpool Clothes Dryer 8577194 User Manual
Whirlpool Washer Dryer 3953953 User Manual
White Rodgers Thermostat 1F80 24 User Manual
Woods Equipment Compact Loader MANO472 User Manual
Worksaver Brush Cutter SDM40 48 User Manual
Xtant Stereo Amplifier Model X1001 User Manual
Yamaha CD Player CDR400At User Manual
Zanussi Cooktop ZCV663 User Manual
Zanussi Oven ZOU 363 User Manual