‘Wolflite’ Safety Handlamp H-251E &
H-251 Mk1 & Mk2
Operation & Maintenance Instructions
H–18Y H–17 H–31Y
H–15Y
Wolflite
Safety
H–21A
H–30
H–03
Handlamp
H–24
H–26
H–19
H–25
H-251E
H–22
H–104
H–14
H–29
H–66
H–12
H–13
H–09
H–48
H–11
H–62 H–63 H–41E
Download from Www.Somanuals.com. All Manuals Search And Download.
‘Wolflite’ H-251 Rechargeable Safety Handlamp Range
Operation & Maintenance Instructions
Certification
H-251E
EEx e ib IIC T4
EEx e s II T3
Certificate: BASEEFA Ex 843292
Certificate: BASEEFA Ex 81142
–
H-251 Mk1 & Mk2
Certificate: 86/00097
Use of Wolflite Handlamps in Hazardous Areas
•
The H-251E Handlamp is certified for use in potentially explosive gases, vapours and mists. Applicable standards: EN50014:1977,
EN50019:1977, EN50020:1977.
•
The H-251 Mk1/Mk2 Handlamps are certified for use in potentially explosive gases and vapours. Applicable standards: EN50014:1977,
EN50019:1977, SFA 3009:1972.
•
•
Ingress protection level for H-251E and H-251 Mk1: IP66, to EN60529:1992 for H-251 Mk2: IP54 to EN60529:1992.
Users are advised to consult BS 5345: Part 1:1989 ‘Code of Practice for the Selection, Installation and Maintenance of Electrical Apparatus for
use in Potentially Explosive Atmospheres’ or National equivalent.
•
The lamp must not be opened or fitted with replacement parts in a hazardous area. Lamp chargers must be kept and operated in non
hazardous areas and in clean and dry conditions; a damaged lamp should be carefully examined for its continued safety. If in doubt, it should
be withdrawn from use and returned to the manufacturer for repair.
•
•
•
The ‘Wolflite’ Handlamp may constitute a static hazard and should be cleaned only with a damp cloth.
Heavily soiled lamps must not be immersed in water or exposed to high pressure water jets for cleaning.
Maintenance and repair must be carried out by a competent technician/electrician familiar with Certified Electrical Apparatus and in accordance
with these maintenance instructions, using factory supplied spare parts only.
•
Handlamp operating ambient in Hazardous Areas: -20°C to +40°C
Before Use
Charge battery before first use. To prevent accidental discharge of the battery in transit, the switch is locked in the OFF position.
To Lock/Unlock the Lamp (H-251 Mk1 & Mk2 only)
The stainless steel lock screw in front of the handle interlocks with the operating switch. Screw anti-clockwise to lock the lamp enclosure and
release the operating switch. The lock key provided must be kept in a non-hazardous area.
WARNING: The Lock Screw bush can be dislodged if overtightened. Switch ‘OFF’ before screwing the Lock Screw down.
To Operate and Dismantle the Switch
The switch operates transversely, as indicated on the approval label. It consists of a magnet, a plastic housing and a cap. To replace, the old cap is
prised off and the housing removed. The new switch housing/magnet is fitted to the body before the cap is ‘snapped’ in place.
To Open the Lamp
Unlock as above, unscrew the lens ring from the body to gain access to all internal parts.
To Replace the Bulb
The bulb (3.6 Volts, 1.0 Amp) is retained by the screwed centre contact at the back of the reflector.
To Replace the Glass Disc and/or Reflector
The toughened glass disc and reflector are secured in the lens ring by the reflector retaining ring. The battery retainer (H-251 MkI/ Mk2 only) is
‘snap’ fitted in the lens ring, remove before unscrewing the reflector retaining ring. All parts must be cleaned and the rubber washer centralised
before re-assembly. A key is available for fastening/unfastening this assembly.
To Replace Fuse and/or Reed Switch
The fuse contact must be removed to replace the fuse (Shorting Link in H-251E). To replace the reed switch, the battery contact and fuse contact
must be removed.
To Replace the Battery for the H-251 Mk2
The positive and negative diode leads are disconnected from their respective terminals and the battery pack is removed from the body cavity.
To Replace the Battery for the H-251E
All connections are automatically made when the H-251E battery pack is replaced. The battery pack is a slide fit in the body cavity, clean the new
battery pack and spring contacts prior to fitting. The H-251E battery pack is deep discharge protected, it will switch off after approximately four
hours duration, preventing damage to the battery.
Download from Www.Somanuals.com. All Manuals Search And Download.
The Battery
A Lead Acid cell system is used in all ‘Wolflite’ Safety Handlamps. A minimum of four hours continuous output is provided for an average of 500
recharging cycles. A common battery pack is used for the H-251 Mk1 and H-251 Mk2. The H-251E battery pack has an encapsulated control and
current limiting circuit, and has been tested for EMC compliance and CE marked accordingly. For optimum performance and safety please observe
the following:
•
•
•
•
Charge before first use.
Avoid deep discharge.
Recharge immediately when flat.
Recharge every six months when stored.
Note:
Dangerous Goods Regulations
Hazardous Materials Regulations
Restricted Articles Regulations
The US Dept. of Transport, IATA, and CAA declare these batteries are “not regulated”.
Warning:
Do not short-circuit or incinerate
Do not recharge other than from Wolf Chargers
Do not cut, crush or puncture
Dispose of only via licensed disposal agency
Charging ‘Wolflite’ H-251 Mk1 Battery
To remove the battery for charging remove the lens ring (see “To Open the Lamp’’). The battery removal tab is visible and can be used to aid
extraction. WHILE THE BATTERY IS ON CHARGE THE LENS RING MUST BE REPLACED TO PREVENT DUST ENTERING THE LAMP
ENCLOSURE. If available, a spare charged battery can be fitted.
The Battery is charged in a fully automatic charging unit. Indicators show when a battery has been fully charged. AFTER USE, RE-CHARGE AS
SOON AS POSSIBLE.
Charger Unit C-251 for H-251 Mk1
This ‘Wolflite’ Battery Charger is ‘CE’ marked as compliant with Low Voltage and EMC Directives. Before connecting to the mains ensure the
correct voltage is selected and the battery is in the charger, the indicators will show the state of battery charge and charger mode. 90% capacity is
achieved in 4/5 hours. The charger indicators will suffer from electro-magnetic interference when sited less than five metres from sources emitting at
the following frequencies: 103-115MHz, 117-119MHz, 126-136MHz.
Charging ‘Wolflite’ Handlamps H-251 Mk2 and H-251E
The battery is charged within the lamp body. The H-251 Mk2 Handlamp switch must be in the ‘OFF’ position when on charge. The H-251E can
be switched ‘ON’ when charging, the lamp is then set for stand-by power failure mode and will automatically illuminate should power to the charger
be cut. Indicators show the state of charge of the battery. Red only indicates the Lamp has not made correct contact, the Lamp must be pushed
firmly until latched in position.
Lamp Chargers for H-251 Mk2 and H-251E
Two types of Lamp Chargers are available – HIGH VOLTAGE and LOW VOLTAGE, to suit fixed or mobile applications. The chargers are ‘CE’
marked as compliant with Low Voltage and EMC Directives.
Wolflite Charger C-251HV is for mains AC input voltages of 200-240 volts at 50-60 Hz (Off-shore platform voltages of 254 volts at 60
Hz), user switchable to 100-120 volts at 50-60 Hz. Failure to select the correct voltage may cause damage. Charger achieves 90%
recharge in 6/7 hours. Only fit manufacturer’s specified fuse. Chargers are fitted with Approved plugs, refer to sales literature for details.
Wolflite Charger C-251LV is suitable for use from DC supplies of 12 to 32 volts. A full recharge from a 12 volt supply takes 20/24
hours, but from a 24 volt supply 10/12 hours. The two-core flex is red, positive and black, negative.
Both chargers are fully automatic, stepping to a safe trickle charge level after the main charge is completed.
NOTE:
A fully discharged battery must be charged immediately to avoid damage.
The charger contacts are of low voltage output and short circuit protected.
Charger operating ambient: +10°C to +25°C.
WARNING: THE WOLFLITE CHARGERS ARE DESIGNED FOR CHARGING WOLFLITE HANDLAMPS ONLY – NO OTHER BATTERIES OR
BATTERY OPERATED DEVICES ARE TO BE USED
The Wolf Safety Lamp Co. Ltd. have a policy of continuous product review and improvement, and changes in design details whether
permitted as Variations of Approvals or otherwise may be made without prior notice.
Download from Www.Somanuals.com. All Manuals Search And Download.
‘Wolflite’ Safety Handlamp H-251E &
H-251 Mk1 & Mk2
Operation & Maintenance Instructions
H–18 H–17 H–31 H–08
H–15
Wolflite
Safety
H–21A
H–30
H–03
Handlamp
H–24
H–26
H–19
H-251 Mk1
H–25
H–22
H–02
H–23 H–29
H–16E
H–12
H–13
H–14
H–09
H–10
H–11
Download from Www.Somanuals.com. All Manuals Search And Download.
Spare Parts List for ‘Wolflite’ Safety Handlamp
H-251E & H-251 Mk1 & Mk2
Description
’O‘ ring seal
Magnet switch complete
Lock screw
Reed switch
Fuse for lamp, & link (H-251E)
Sleeve for fuse holder
Fuse contact
Battery contact
Screw for contacts
Body complete
Battery pack
Lens ring
Rubber washer for glass disc
Glass disc
Reflector
Reflector retaining ring
Battery retainer
Reflector distance piece
Bulb socket
Bulb 3.6v 1.0A Krypton (4 hrs.)
Bulb 4.8v 0.5A Krypton (8 hrs.)
Centre contact complete
Reflector c/w bulb and fittings
Lens ring complete
Hexagon lock key 4 mm
Key for reflector retaining ring
Lanyard and fittings
Nut for contact stud
Spring washer for nut
Diode lead (positive)
Diode lead (negative)
Terminal tab
H-251 Mk1
H-02
H-03
H-08
H-09
H-10
H-11
H-12
H-13
H-14
H-15
H-16E
H-17
H-18
H-19
H-21A
H-22
H-23
H-24
H-25
H-26
H-26K
H-29
H-30
H-31
H-33
H-34
H-35
–
H-251 Mk2
–
H-251E
H-104
H-03
H-08
H-09
H-48
H-11
H-12
H-13
H-14
H-15Y
H-66
H-17
H-18Y
H-19
H-21A
H-22
–
H-24
H-25
H-26
H-26K
H-29
H-30
H-31Y
H-33
H-34
H-35B
H-62
–
H-03
H-08
H-09
H-10
H-11
H-12
H-13
H-14
H-15E
H-16E
H-17
H-18
H-19
H-21A
H-22
H-23
H-24
H-25
H-26
H-26K
H-29
H-30
H-31
H-33
H-34
H-35
H-36E
H-37E
H-38E
H-39E
H-40E
H-41E
H-58
–
–
–
–
–
–
–
–
Support washer
Handlamp wall holder
Stud seal
–
H-41E
H-58
H-63
C-251LV
C-57
–
H-58
–
C-251
C-251HV
–
–
–
Clip for LV charger
Rocker switch for charger
Transformer 9V, 20VA
Printed circuit board
Lamp charger contacts
PCB for LV DC charger
Rocker switch for HV charger
PCB for HV charger
Washer for clip
–
C-62
C-63
C-69
–
–
–
–
–
–
–
–
–
–
C-71
–
C-82
C-84
–
C-71
C-81
–
–
T-2056
T-2057
C-6021
–
Rivet for clip
Support spring
Fuse for charger
–
C-6021
H-10
H-10
WOLF SAFETY LAMP COMPANY
Saxon Road Works, Sheffield S8 0YA, England
Tel: +44 114 255 1051 Fax: +44 114 255 7988
E-mail: info@wolf-safety.co.uk
MMD/U/?K/6.03
Download from Www.Somanuals.com. All Manuals Search And Download.
|