| F I N D O U T M O R E ON THE WEB.   W I L B U RC U RT I S . C O M   WILBUR CURTIS COMPANY, INC.   D500 Generation 3 - Airpot Brewer Instructions   Important Safeguards/Conventions   Models Included   • D500GT   • D500GT/H   This appliance is designed for commercial use. Any servicing other than cleaning and maintenance   should be performed by an authorized Wilbur Curtis service center.   • Do NOT immerse the unit in water or any other liquid   • To reduce the risk of fire or electric shock, do NOT open top or rear panel. No user serviceable parts inside. Repair should   be done only by authorized service personnel.   • Keep hands and other items away from hot parts of unit during operation.   • Never clean with scouring powders, bleach or harsh implements.   Conventions   WARNINGS – To help avoid personal injury   WARNING HOT LIQUID,   Scalding may occur.   Avoid splashing.   Important Notes/Cautions   Sanitation Requirements   – from the factory   CAUTION: Please use   this setup procedure   before attempting to use   this brewer. Failure to follow the   instructions can result in injury or   Your Curtis ADS System is Factory Pre-Set and Ready to Go… Right out of the Carton.   Following are the Factory Settings for your D500GT Airpot Coffee Brewing System:   • Brew Temperature   = 200°F   the voiding of the warranty.   • Brew Volume = Set to dispensing vessel requirements (2.2 liters)   Generally there will never be a reason to change your ADS programming. However, should you need to make slight adjustments   to meet your brewing needs, programming instructions are provided later in this manual.   CAUTION: DO NOT   connect this brewer to   hot water. The inlet valve   System Requirements:   • Water Source 20 – 90 PSI (Minimum Flow Rate of 1 GPM)   Equipment to be installed to comply with applicable federal, state, or local plumbing/electrical codes having jurisdiction.   is not rated for hot water.   SETUP STEPS   The unit should be level (left to right and front to back), located on a solid counter top. Connect a water line from the water filter to the   brewer. NOTE: Some type of water filtration device must be used to maintain a trouble-free operation. (In areas with extremely hard   water, we suggest that a sedimentary and taste & odor filter be installed.) This will prolong the life of your brewing system and   enhance coffee quality.   CAUTION: When   cleaning, DO NOT use   powders, liquids,   cleansers, or any substance   containing chlorine. These   products promote corrosion,   cause pitting of stainless steel and   will void the warranty.   The National Sanitation Foundation requires the following water connection:   1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine can be moved   for cleaning underneath.   2. In some areas an approved backflow prevention device may be required between the brewer and water supply.   1. A 3/8” NPT x 1/4” Flare elbow has been supplied for water line connection. Use tubing sized sufficiently to provide a minimum of   1.0 GPM.   2. Connect the unit to an appropriate electrical power circuit.   3. Turn on the toggle (STANDBY/ON) switch behind the unit. The heating tank will start to fill. When the water level in the tank rises   to the correct volume, the heating elements will energize automatically. With ADS Systems there is no danger of element burnout   caused by an empty tank.   4. The heating tank will require 20 to 30 minutes to reach operating temperature (200°F) as indicated by the READY-TO-BREW   indicator light.   5. Prior to brewing, dispense 12 ounces of hot water through the hot water faucet.   6. Brew a cycle of at least 12 ounces, to purge the water lines of any air that may be trapped after filling.   BREWING INSTRUCTIONS   1. Brewer should be ON (Confirm at rear toggle switch, then press ON/OFF button). Ready-to-Brew should be displayed.   2. Place empty airpot on deck.   3. Place filter in brewcone.   C 4. Pour ground   coffee into   5. Position   brewcone   into brew   rails.   ISO 9001 REGISTERED   6.Press Brew   button.   brewcone.   WILBUR CURTIS COMPANY   Montebello, CA 90640   FOR THE LATEST SPECIFICATIONS AND INFORMATION GO TO   WWW.WILBURCURTIS.COM   1 Download from Www.Somanuals.com. All Manuals Search And Download.   Pulse Brew (Factory set to OFF)   Press ꢀto select, < or > to select OFF or one of four pulse patterns (A to D) .   Guidelines for Pulse Brew:   This feature allows tuning of the coffee flavor.This option should only be used with the standard Gray or Purple AFS sprayheads.The pot level should always be set first with this option OFF.   Depending on your grind profile and water conditions, the three Pulse Brew options help “tune”or change the coffee flavor. Filter Pack type coffees typically extract better with theA and B pulse setting.   Decaffeinated coffees typically extract better with the B pulse setting. High-Yield coffees typically extract better with the C pulse setting. Of course, any of the A, B or C settings may be used to suit your taste   profile.   If Pulse Brew is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point and Cold Brew Lock disappears from the list of program selections.   When Pulse Brew is ON, Pre-infusion disappear from the list of program selections.   Model Select   Press ꢀto select, < or > to select desired model (ALPHA-1,ALPHA-2,ALPHA-3/4/5,Airpot Brewer,Thermo-Alpha) Press ꢀto set.The control will reset itself when a new model is selected.   Exit   Press ꢀto select, exits program mode and returns unit to operation.   Tank Temperature Check   Turn on brewer at the control panel ON/OFF button. Press and hold 3 button (see illustration, page 2) for 5 seconds. Water Temperature will be displayed (temperature in heating tank).   PARTS DIAGRAMS   18   19   20   21   16   27   28   25   26   22   23   17   16   24   29   D 15   6 7 D 1 8 2 3 Illustrated Parts List – D500GT   Nº Part Nº   D e s c r i p t i o n   1 2 3 4 5 WC-2977   WC-37064   WC-39346   WC-1809   WC-3621   FITTING ASSY, SPRAYHEAD   KIT, LABEL & UCM D500GT CURTIS   LABEL, CNTRL PNL (CURTIS LOGO)   FAUCET, HOT WATER W/JAM NUT   BREWCONE, UNIV7 1/8" BLK PLASTIC   BREW CONE, ASSY S.S. (OPTIONAL)   BREWCONE ASSY, WITH BYPASS (OPTNL)   TUBING, SILICONE, 5/16" I.D. ( 1 FT.)   COVER, TOP   4 5A WC-3316   5B WC-3316-101   6 7 8 9 5 WC-5310   WC-5450   WC- 889   WC-2936   13   14   9 VALVE, DUMP RIGHT 120V   SPRAYHEAD, RED (.131 DIA.)   SWITCH, TOGGLE 125/250 VAC RESISTIVE   GRID, DRIP TRAY AIRPOT   LEG, SCREW BUMPER 3/8-16 STD   VALVE, INLET 1 GPM 120V 10W   CAPACITOR, X2   KIT, VALVE REPAIR USE ON WC-889   KIT, VALVE REPAIR USE ON WC-826   WASHER, FLW ½” 1.0 GPM USE W/WC-826   TANK COMPLETE, D500GT 120V   COVER, TANK W/NOTCHES   PROBE ASSY, WATER LEVEL   HEATING ELMNT 1450W 120V W/NUTS   GUARD, SHOCK HEATING ELEMENT   THERMOSTAT, HI LIMIT HEATER CONTROL   THERMOSTAT, MANUAL RESET   GUARD, SHOCK RESET THERMOSTAT   GASKET, HEATING TANK   10 WC- 102   11 WC-6221   12 WC-3503   13 WC- 826   14 WC-8591   15 WC-3763   16 WC-3765   17 WC- 830   18 WC-6277   19 WC-5851   20 WC-5502-01   21 WC- 917   22 WC-4394   23 WC- 522   23A WC- 523   24 WC-43055   25 WC-43062   26 WC-43058   27 WC-1438-101   28 WC-5231   29 WC-37098   10   11   12   5A   5B   PLUG, TANK DRAIN, PP RED   SENSOR, HEATING TANK   COMPOUND, SILICONE 5 OZ TUBE   KIT, BYPASS GEN USE   3 Download from Www.Somanuals.com. All Manuals Search And Download.   ELECTRICAL   SCHEMATIC   Product Warranty Information   The Wilbur Curtis Company certifies that its products are free from defects in material and workmanship under normal use. The following limited warranties and conditions apply:   3 Years, Parts and Labor, from Original Date of Purchase on digital control boards.   2 Years, Parts, from Original Date of Purchase on all other electrical components, fittings and tubing.   1 Year, Labor, from Original Date of Purchase on all electrical components, fittings and tubing.   Additionally, the Wilbur Curtis Company warrants its Grinding Burrs for Forty (40) months from date of purchase or 40,000 pounds of coffee, whichever comes first. Stainless Steel components are warranted for two (2) years from   date of purchase against leaking or pitting and replacement parts are warranted for ninety (90) days from date of purchase or for the remainder of the limited warranty period of the equipment in which the component is installed.   All in-warranty service calls must have prior authorization. For Authorization, call the Technical Support Department at 1-800-995-0417. Effective date of this policy is April 1, 2003.   Additional conditions may apply. Go to www.wilburcurtis.com to view the full product warranty information.   CONDITIONS & EXCEPTIONS   The warranty covers original equipment at time of purchase only. The Wilbur Curtis Company, Inc., assumes no responsibility for substitute replacement parts installed on Curtis equipment that have not been purchased from the   Wilbur Curtis Company, Inc. The Wilbur Curtis Company will not accept any responsibility if the following conditions are not met. The warranty does not cover and is void under the following circumstances:   1 )   2 )   3 )   4 )   5 )   Improper operation of equipment: The equipment must be used for its designed and intended purpose and function.   Improper installation of equipment: This equipment must be installed by a professional technician and must comply with all local electrical, mechanical and plumbing codes.   Improper voltage: Equipment must be installed at the voltage stated on the serial plate supplied with this equipment.   Improper water supply: This includes, but is not limited to, excessive or low water pressure, and inadequate or fluctuating water flow rate.   Adjustments and cleaning: The resetting of safety thermostats and circuit breakers, programming and temperature adjustments are the responsibility of the equipment owner. The owner is responsible for proper   cleaning and regular maintenance of this equipment.   6 )   7 )   Damaged in transit: Equipment damaged in transit is the responsibility of the freight company and a claim should be made with the carrier.   Abuse or neglect (including failure to periodically clean or remove lime accumulations): Manufacturer is not responsible for variation in equipment operation due to excessive lime or local   water conditions. The equipment must be maintained according to the manufacturer’s recommendations.   8 )   9 )   Replacement of items subject to normal use and wear: This shall include, but is not limited to, light bulbs, shear disks, “0” rings, gaskets, silicone tube, canister assemblies, whipper chambers and plates,   mixing bowls, agitation assemblies and whipper propellers.   Repairs and/or Replacements are subject to our decision that the workmanship or parts were faulty and the defects showed up under normal use. All labor shall be performed during regular working hours. Overtime   charges are the responsibility of the owner. Charges incurred by delays, waiting time, or operating restrictions that hinder the service technician’s ability to perform service is the responsibility of the owner of the equipment.   This includes institutional and correctional facilities. The Wilbur Curtis Company will allow up to 100 miles, round trip, per in-warranty service call.   RETURN MERCHANDISE AUTHORIZATION: All claims under this warranty must be submitted to the Wilbur Curtis Company Technical Support Department prior to performing any repair work or return of this equipment   to the factory. All returned equipment must be repackaged properly in the original carton. No units will be accepted if they are damaged in transit due to improper packaging. NO UNITS OR PARTS WILL BE   ACCEPTED WITHOUT   A RETURN MERCHANDISE AUTHORIZATION (RMA). RMA NUMBER MUST BE MARKED ON THE CARTON OR SHIPPING LABEL. All in-warranty service calls must be   performed by an authorized service agent. Call the Wilbur Curtis Technical Support Department to find an agent near you.   WILBUR CURTIS CO., INC.   6913 Acco St., Montebello, CA 90640-5403 USA   Phone: 800/421-6150   Fax: 323-837-2410   FOR THE LATEST SPECIFICATION INFORMATION GO TO WWW.WILBURCURTIS.COM   4 Printed in U.S.A. 4/03 F-3240-S Rev D   7/16/02.15.0 . edr 3410 Rev NC   9/11/02 8.1 ecn 5131 Rev A   4/7/3 9.5 ecn 5751 rev B   4/22/3 . 15.0 . ecn 5789 . rev C   . . . Download from Www.Somanuals.com. All Manuals Search And Download.   |