Whirlpool Range WFG231LV User Manual

®
30" (76 cm) Freestanding Gas Range  
PRODUCT MODEL NUMBERS  
PRODUCT DIMENSIONS  
WFG231LV  
Gas supply: Provide a gas supply line of 3/4" (1.9  
cm) rigid pipe to the range location. A smaller size  
pipe on longer runs may result in insufficient gas  
supply. Pipe-joint compounds that resist the action of  
LP gas must be used. Do not use TEFLON® tape. With  
LP gas, piping or tubing size can be 1/2" (1.3 cm)  
minimum. Usually, LP gas suppliers determine the  
size and materials used in the system.  
If local codes permit, a new CSA design-certified, 4 to  
5 ft (122 to 152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9  
cm) I.D., flexible metal appliance connector may be  
used for connecting range to the gas supply line.  
D
A
A. 36" (91.4 cm)  
E
B. 29⁷⁄₈" (75.9 cm)  
C. 24¼" (61.6 cm)  
D. 25¾" (65.6 cm)  
E. 46¼" (117.5 cm)  
A 1/2" (1.3 cm) male pipe thread is needed for  
connection to the female pipe threads of the inlet to  
the appliance pressure regulator.  
The supply line must be equipped with a manual  
shutoff valve. This valve should be located in the  
same room but external to the range. It should be in a  
location that allows ease of opening and closing. Do  
not block access to shutoff valve. The valve is for  
turning on or shutting off gas to the range.  
B
C
Electrical: A 120-volt, 60 Hz, AC-only, 15 amp,  
fused electrical circuit is required. A time-delay  
fuse or circuit breaker is also recommended. It is  
recommended that a separate circuit serving only  
this range be provided.  
CABINET OPENING DIMENSIONS  
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth,  
24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.  
D
If the cabinet depth is greater than 24" (61.0 cm), oven frame must extend  
beyond cabinet fronts by 1/2" (13.0 mm) minimum.  
B
C
IMPORTANT: If installing a range hood or microwave hood combination  
above the range, follow the range hood or microwave hood combination  
installation instructions for dimensional clearances above the cooktop  
surface.  
A
E
A. 18" (45.7 cm) min. clearance upper side cabinet to countertop  
B. 13" (33.0 cm) max. upper cabinet depth  
C. 30" (76.2 cm) min. cabinet opening width  
H
G
D. For minimum clearance to top of cooktop, see NOTE*.  
E. 30¹⁄₈" (76.5 cm) min. opening width  
F. This shaded area recommended for installation of electrical outlet.  
G. This shaded area recommended for installation of rigid gas pipe.  
H. 2" (5.1 cm) min. countertop space to side wall or other combustible  
material  
J
I
I. 24" (61.0 cm)  
J. 10" (25.4 cm)  
K. 8" (20.3 cm)  
L. 5" (12.7 cm)  
M. 2" (5.1 cm)  
N. 3" (7.6 cm)  
F
K
M
L
L
N
*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is  
covered by not less than 1/4" (0.64 cm) flame retardant millboard covered  
with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel,  
0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.  
30" (76.2 cm) minimum clearance between the top of the cooking platform  
and the bottom of an uncovered wood or metal cabinet.  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10200946  
07-30-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weed Eater Tiller 164789 User Manual
Westinghouse Model Vehicle EW40t4FW User Manual
Whistler Radar Detector RLC 100 User Manual
Wolf Griddle TYG48C User Manual
Wolf Range C48B 2FT36 User Manual
Woodstock Grinder M1107 User Manual
Yamaha Mouse EN Keyboard User Manual
Yamaha Stereo Receiver HTR 6180 User Manual
Zanussi Cooktop SC5412 User Manual
Zanussi Dishwasher ZSF 6280 User Manual