Whirlpool Clothes Dryer GGN2000H User Manual

®
Gas Dryer  
DOOR CLEARANCE  
DIMENSIONS  
PRODUCT MODEL NUMBERS  
OVERALL DIMENSIONS  
3-7/8"  
GGN2000H LGQ8858H LGR5600H LGR7646J  
GGQ9858J LGQ8858J LGR5600J LGR8857E  
LGC8858E LGR3624E LGR5636E LGR8858E  
LGN1000H LGR3624J LGR5636J LGT7646E  
LGQ8800J LGR3634E LGR5644E LGW8858H  
LGQ8857H LGR3634J LGR5644J  
22-3/4"  
19-1/8"  
LGQ8857J LGR4634E LGR5848E  
22-3/4"  
14-1/2"  
Gas supply: Dryer is equipped for use with  
NATURAL gas. Dryer can be converted to L.P. gas.  
When rigid pipe is used it should be 1/2 inch IPS.  
When acceptable to the gas supplier and local  
codes, 3/8-inch approved tubing may be used for  
lengths under 20 feet. For lengths over 20 feet,  
larger tubing should be used. Pipe-joint  
dryer exhaust  
vent  
Super-large  
side-swing door (reversible)  
7"  
42-3/8"*  
2-1/8"  
6"*  
9-1/4"  
22-3/4"  
gas burner inlet  
pipe connection  
at rear of dryer  
compounds resistant to the action of L.P. gas must  
be used. If local codes permit, it is recommended  
that new flexible metal tubing, design-certified by  
AGA or CSA, be used for connecting the appliance  
to the rigid gas supply line. (The gas pipe which  
extends through the lower rear of the appliance  
has 3/8-inch male pipe thread.) An individual  
manual shutoff valve must be installed within 6  
feet of the dryer in accordance with the National  
Fuel Gas Code ANSI Z223.1.  
17-3/4"  
29"  
28" max.**  
22-3/4"  
Large side-swing  
door (reversible)  
* from floor with dryer feet extended 1 inch  
** Most installations will require at least 5-inch clearance  
behind the dryer for the dryer vent.  
8-1/4"  
15-1/4"  
Electrical: 120-volt, 60-Hz,  
RECESSED AREA AND CLOSET INSTALLATION  
AC-only, 15- or 20-amp.  
electrical supply. Use copper  
wire only. A time-delay fuse  
or circuit breaker and  
separate circuit is  
15-1/4"  
15-1/4"  
Closet confined area  
Recessed  
area  
If a closet door is installed: The minimum unobstructed  
air openings are required. Louvered doors with equivalent  
air openings are acceptable.  
recommended.  
front view  
front view  
side view  
Small side-swing door  
Exhaust venting: Exhaust  
your dryer to the outside.  
four-inch diameter vent is  
required. Rigid or flexible  
metal exhaust vent must be  
used. Do Not use plastic or  
metal foil vent. Exhaust outlet  
hood must be at least 12  
inches from the ground or  
any object that may be in the  
path of the exhaust.  
3"  
8-3/4"  
25-5/8"  
14"  
48 sq. in.*  
24 sq. in.*  
max.  
closet  
door  
18"  
13-3/4"  
4" **  
3"  
13-3/4"  
Extra-large hamper door  
1"  
0"***  
0"***  
* Minimum top and bottom air openings for closet door.  
**External exhaust elbow requires additional space.  
***Wall, door and floor molding  
may require additional spacing.  
EXHAUST VENTING  
Select the route that will provide the straightest and most direct path outdoors. Plan the  
installation to use the fewest number of elbows and turns. Avoid making 90° turns.  
When using elbows or making turns, allow as much room as possible. Bend flexible  
metal vent gradually to avoid kinking.  
Acceptable  
Preferred  
4"  
4"  
2-1/2"  
Determine vent length  
When you have a 4" hood  
When you have a 2-1/2" hood  
1. See the exhaust vent length chart that matches your type hood for the maximum vent  
lengths you can use.  
Do not use vent runs longer than specified in exhaust vent length charts.  
Maximum length of 4"  
diameter metal vent  
Maximum length of 4"  
diameter metal vent  
Number of  
90° elbows  
Rigid  
Flexible  
(fully extended)  
Number of  
90° elbows  
Rigid  
Flexible  
(fully extended)  
2. Determine the number of elbows you will need.  
0
1
2
3
4
64 ft.  
54 ft.  
44 ft.  
35 ft.  
27 ft.  
36 ft.  
31 ft.  
27 ft.  
25 ft.  
23 ft.  
0
1
2
3
4
58 ft.  
48 ft.  
38 ft.  
29 ft.  
21 ft.  
28 ft.  
23 ft.  
19 ft.  
17 ft.  
15 ft.  
3. In the column listing the type of metal vent you are using (rigid or flexible), find the  
maximum length of metal vent on the same line as the number of elbows.  
The maximum length using a 2" x 6" rectangular vent with 2 elbows and a 2-1/2"  
exhaust hood is 8 ft.  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 3405338 Rev. D  
01-09-03  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weed Eater Trimmer 530163506 User Manual
Weider Home Gym WEBE06350 User Manual
Weslo Treadmill WLTL21280 User Manual
Westcott Camera Accessories 4892 User Manual
Wharfedale Portable Speaker 8 Passive User Manual
Woodstock Saw W1755 User Manual
Woodstock Trimmer M1044 User Manual
Zanussi Dishwasher 534316 User Manual
Zanussi Dishwasher ZWS 744 User Manual
Zanussi Washer Dryer ZWF 16281 W User Manual