Western Telematic Video Game Console CMS 16 User Manual

WTI CMS-16; Console Management Switch -- User's Guide  
WTI Part No. 13027  
Rev. B  
CMS-16  
Console Management Switch  
User's Guide  
5 Sterling, Irvine, California 92618-2517 USA  
U.S. & Canada: (800) 854-7226  
Phone: (949) 586-9950  
Fax: (949) 583-9514  
Warnings and Cautions:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (1 of 59) [11/15/2000 10:52:02 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
2. Open Racks: Make certain that the rack frame does not block the ventilation slots on the  
instrument cover. If the device is installed on sliders, check the unit when seated all the  
way into the rack to make certain that ventilation slots are not blocked.  
Ventilation  
Slots in the instrument cover are provided to allow ventilation for heat dissipation. To ensure  
safe, reliable operation, these openings must not be covered or blocked.  
Disconnect Power  
If any of the following events are noted, immediately disconnect the unit from the outlet and  
contact qualified service personnel:  
If the power cord becomes frayed or damaged.  
If liquid has been spilled into the device or if the device has been exposed to rain or water.  
Table of Contents  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (3 of 59) [11/15/2000 10:52:02 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (4 of 59) [11/15/2000 10:52:02 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
1. Introduction  
The CMS-16 Console Port Management Switch provides secure, in-band and/or out-of-band  
access to RS232 console ports and maintenance ports on UNIX servers, routers and other  
network equipment. System Administrators can access remote devices in order to change  
configuration parameters, connect users to restricted ports, collect buffered data, and perform a  
variety of other administrative functions.  
Versatile Connectivity  
Up to 16 different devices can be connected to the CMS without the need to select a common  
baud rate or parity. Each port can be individually configured for specific baud rates, parity,  
handshaking, and various other parameters and options.  
Easy Set-Up and Operation  
Configuration of the CMS is simple. A menuing system is used to select parameters, and enable  
options. The CMS can easily adapt to the requirements of almost any data communications  
application.  
Limited Command Access  
The CMS is ideal for situations that require limited access to important commands. Two  
security levels allow each port to function as a Supervisor Port or User Port, depending on the  
password entered at login. Supervisor Ports are allowed to change configuration, display status,  
and connect to any other port; User ports are only allowed to connect to the ports provided by  
their password. Each individual port can be assigned its own unique, user-defined password, up  
to sixteen characters long.  
Non-Volatile Memory  
If AC power to the unit is lost or interrupted, the CMS's non-volatile memory will retain  
user-defined parameters and port connections.  
Modem and Telnet Communication  
The CMS can be controlled by a local PC that communicates with the unit via cable, or  
controlled remotely via external modem or telnet connection. Your terminal emulation or telnet  
program is used to send commands to connect ports or display status.  
Configuration Backup  
Once you have configured the CMS to fit your application, parameters and options can be saved  
to an ASCII text file on your PC. This allows you to quickly restore user-selected parameters if  
the unit configuration is accidentally altered or deleted. Saved parameters can also be uploaded  
to other CMS units. This allows rapid set-up when several units will be configured with identical  
or similar parameters.  
Typographic Conventions  
Throughout this User's Guide, typefaces and characters are used to denote the following:  
^
Indicates a control character. For example, the text "^X" (Control X)  
indicates the [Ctrl] key and the [X] key must be pressed  
simultaneously.  
(e.g. ^X)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (6 of 59) [11/15/2000 10:52:02 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
COURIER FONT  
Indicates characters typed on the keyboard. For example, /Eor /P 02.  
[Bold Font]  
Text set in bold face and enclosed in square brackets, indicates a  
specific key. For example, [Enter] or [Esc].  
< >  
[ ]  
Indicates required keyboard entries: For Example: /P <n>.  
Indicates optional keyboard entries. For Example: /W [n].  
2. Unit Description  
2.1. Front Panel  
Figure 2.1: Instrument Front Panel  
1. CLEAR: Restarts the CMS operating program without changing user-selected parameter  
settings or breaking port connections.  
2. ON: Lights when AC Power is applied.  
3. SET: Used to Initialize the CMS to defaults specified by the SetUp Switches. To  
initialize, press and hold both the SET and CLEAR buttons, release only the CLEAR  
button, wait for the Port LEDs to flash, and then release the SET button.  
Note:  
During initialization, all port LEDs will flash ON three times.  
During initialization, all command-selected parameters will be cleared, and the  
CMS will revert to the default parameters specified by the Option Switches.  
4. RDY: (Ready) Flashes to indicate unit is operational.  
5. NET: Lights when a Network Connection is present.  
6. ACTIVITY LEDs: Light to indicate data activity at the corresponding port. The CMS-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (7 of 59) [11/15/2000 10:52:02 AM]  
     
WTI CMS-16; Console Management Switch -- User's Guide  
includes sixteen Activity LEDs, and the CMS-8 includes eight Activity LEDs.  
2.2. Back Panel  
Figure 2.2: Instrument Back Panel  
1. Network Port: An RJ45 Ethernet port for connection to your TCP/IP network. To  
communicate via network, you must first specify the IP Address, Subnet Mask, and  
Gateway Address as described in Section 5.5.4.  
2. Power Cable Receptacle  
3. Power Switch  
4. RS232 PORTS: For connection to console ports on target devices. Standard DB9  
connectors configured as DTE ports. The RS232 ports are similar to a serial port on a PC.  
When connecting a modem, use a standard serial cable. When connecting a PC or other  
DTE device use a null modem cable.  
Ports 1 and 2 are System Setup Ports, which are used for communication during  
set-up and configuration. Note that Supervisor Level command access cannot be  
disabled at these ports.  
Ports 1 and 2 can either be connected to a PC or modem. Connection to a modem  
allows control by a remote PC.  
5. Option Switches: A bank of eight DIP switches, which are used to set the default baud  
rate, handshake, message type, and duplex mode. Option Switch functions are described in  
3. Getting Started  
This section provides a brief overview of basic CMS capabilities, and describes simple tests that  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (8 of 59) [11/15/2000 10:52:02 AM]  
     
WTI CMS-16; Console Management Switch -- User's Guide  
can be used to determine if the unit is operating properly.  
3.1. Communication Parameters  
The Option Switches, located on the instrument back panel, select default operating settings.  
Switch functions are summarized in Section 4.2, and on a label on the CMS unit.  
When the unit is shipped from the factory, the Option Switches are set for 9600 baud, 8 Bits-No  
Parity, RTS/CTS handshaking, verbose response, and command echo ON (all switches Down).  
For this overview only, use the default switch configuration. Set your communications program  
(e.g. ProComm©) to the parameters listed below. After completing this overview and installing  
the unit, please refer to Section 5 for instructions on selecting faster communication speeds and  
other parameters.  
9600 Baud  
RTS/CTS Handshaking  
Full Duplex (Command Echo ON)  
8 Bits, No Parity, 1 Stop Bit  
Using Other Parameters for this Overview (Optional):  
If desired, the CMS can match the parameters used by your communications program. Refer to  
Section 4.2 and configure Option Switches accordingly. After changing the switches, reset the  
CMS; press and hold both the SET and CLEAR buttons, release only CLEAR, wait for the Port  
LEDs to flash, and then release the SET button.  
Note: If Option Switches are changed, new settings will not take effect until the  
unit is reset.  
3.2. Apply Power to the CMS  
Connect the CMS to an appropriate power source. Press the Power Switch ON. The ON LED  
should light, and the RDY LED should begin to flash. When connecting power to a DC unit,  
please refer to the additional instructions in Section 4.1.  
CAUTION: This device should only be operated with the type of power source  
indicated on the instrument nameplate. If you are not sure of the type of power  
service available, please consult your local power company.  
3.3. System SetUp Ports  
In order to ensure access to important command functions, Ports 1 and 2 are designated as  
System SetUp Ports; the Supervisor Mode cannot be disabled at these ports. Ports 1 and 2 will  
always allow password protected access to all CMS command functions, even when the unit has  
been reset to the default state.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (9 of 59) [11/15/2000 10:52:02 AM]  
     
WTI CMS-16; Console Management Switch -- User's Guide  
Therefore, Ports 1 and 2 are generally used for communication during initial set-up and  
configuration, or after the unit has been reinitialized (reset) to default parameters.  
Note: For more information on System SetUp Port capabilities, please refer to  
3.4. Connecting your PC to the CMS  
The CMS can either be controlled by a local PC that communicates via cable, controlled via  
external modem, or controlled via TCP/IP network. For this overview, a local PC running  
ProComm (or a similar communications program), will be cable connected to Port 1.  
Note: Communication via Modem (Optional): If desired, this overview can also  
be performed via modem. Section 4.4 describes the procedure for connecting a  
modem to the CMS.  
1. Attach a standard null modem cable to your PC COM port. Make certain to connect to the  
COM port used by your communications program.  
2. Connect the other end of the cable to CMS Port 1. For a description of the port interface,  
please refer to Appendix A.  
3.5. Communicating with the CMS Unit  
Perform the following procedure to access the CMS Command Mode, explore basic features,  
and check for proper operation.  
1. Start your communications program (e.g. ProComm) and set it to 9600 bps, 8 bits, no  
parity, 1 stop bit.  
2. Press [Enter] to access the CMS Command Mode.  
. In order for [Enter] to be recognized as a wake-up command, it must be pressed  
without any characters preceding it.  
b. If you have already hit other keys, press [Enter] twice. The "CMS>" prompt should  
appear.  
c. (Optional) If you are performing this overview via modem, please refer to  
Section 5.1 for additional instructions.  
3. The Port Status Screen will be displayed, followed by the "CMS>" prompt, indicating that  
you have successfully accessed the Command Mode. If the "CMS>" prompt is not  
displayed, this may indicate a communication problem. Check the following:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (10 of 59) [11/15/2000 10:52:02 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
. Cable Connection: Check the connection between the CMS and the PC. Make  
certain the cable connectors are firmly seated.  
b. Communication Parameters: Make certain the CMS and ProComm are using the  
same baud rate.  
4. Help Screen: Type /H[Enter] to display the Supervisor Level Help Screen (Figure 3.1).  
COMMAND MENU  
DISPLAY  
/S[P]  
/SD  
CONFIGURATION  
Port Status  
Port Diagnostics  
/F  
System Parameters  
/P [n] Port Parameters  
/W[P] [n] Port Parameters (Who)  
/J  
/N  
/I  
Network Parameters  
Default & Test  
Site ID  
/SN  
/H  
Network Status  
Command Menu (Help)  
/UF Upgrade Firmware  
/CP Copy Port  
Parameters  
CONTROL  
<Enter>  
/X  
/C <n> [n]  
/D <n| ... |*> Disconnect  
/E <n| ... |*> Erase Buffer  
Enter Command Mode  
Exit Command Mode  
Connect Local [Remote]  
+-----------------------+  
| n Port # or Name |  
| * All  
| | "or"  
|
|
| <> Required Entry |  
| [] Optional Entry |  
/U  
/T  
Send Parameter File  
Reset Network Interface +-----------------------+  
/D, /E, /I, /T Commands: Add /Y to bypass "Sure (Y/N)?"  
Figure 3.1: The Supervisor Level Help Screen  
5. Port Status Screen: Type /S[Enter] to display the Port Status Screen (Figure 3.2),  
which summarizes conditions at all Ports. The various fields of the Port Status Screen are  
explained in Section 6.1.  
PORT STATUS: Version 1.02, Site ID: (undefined)  
PORT |  
NAME  
|
PASSWORD  
| STATUS | MODE | BUFFER COUNT  
-----+------------------+------------------+--------+------+--------------  
01 | (undefined)  
02 | (undefined)  
03 | (undefined)  
04 | (undefined)  
05 | (undefined)  
06 | (undefined)  
07 | (undefined)  
08 | (undefined)  
|
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
|
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
0
0
0
0
0
0
0
0
|
|
|
09 | (undefined)  
10 | (undefined)  
| (undefined)  
| (undefined)  
| Free | Any |  
| Free | Any |  
0
0
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (11 of 59) [11/15/2000 10:52:02 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
11 | (undefined)  
12 | (undefined)  
13 | (undefined)  
14 | (undefined)  
15 | (undefined)  
16 | (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
0
0
0
0
0
0
Enter /H for Command Menu  
Figure 3.2: The Port Status Screen (Defaults Shown)  
6. Port Connection: The CMS can perform two different types of port connections;  
Resident Connections and Third Party Connections.  
. Resident Connection: Your resident port (e.g. Port 1) issues a /C command to  
connect to a second port.  
i. To connect Port 1 to Port 2, type /C 2 [Enter]. While Port 1 is connected,  
the CMS will not recognize commands issued at Port 1. However, the unit  
will recognize a Resident Disconnect Sequence issued at Port 1 or Port 2.  
ii. Issue the Resident Disconnect Sequence (Logoff Sequence); type  
[Enter]+++[Enter].  
b. Third Party Connection: Your resident port (e.g. Port 1) issues a /C command to  
create a connection between two other ports.  
i. To connect Port 2 to Port 3, type /C 2 3 [Enter].  
ii. While Ports 2 and 3 are connected, Port 1 will still recognize CMS  
commands. Type /S [Enter] to display the Port Status Screen. The  
"STATUS" column should now list Ports 2 and 3 as connected, and Port 1 as  
"Free".  
iii. Issue a Third Party Disconnect command to disconnect Ports 2 and 3; type  
/D 2 [Enter]. The unit will display the "Are you Sure (y/n)?" prompt. Type  
yand press [Enter] to disconnect.  
iv. Type /S [Enter] to display the Port Status Screen. The "STATUS" column  
should now list Ports 2 and 3 as "Free".  
7. Site I.D. Message: If desired, the Site I.D. Message can be used to indicate the name or  
location of the unit. Note that the Site I.D. cannot include double quotes (").  
. Type /Fand press [Enter]. When the System Parameters menu appears, type 1and  
press [Enter]. A prompt will appear. Key in the desired text (up to 32 characters)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (12 of 59) [11/15/2000 10:52:02 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
and press [Enter].  
b. To display the Site I.D., type /J [Enter].  
c. Note that the Site I.D. will be cleared when the  
unit is initialized.  
This completes the introductory overview of the CMS. Please proceed to Section 4 and  
Section 5 for complete installation and configuration procedures.  
4. Hardware Installation  
4.1. Connecting Power to the CMS Unit  
The CMS is available in both AC and DC powered versions. When connecting AC or DC power  
to the CMS, proceed as follows:  
CAUTION: This device should only be operated with the type of power source  
indicated on the instrument nameplate. If you are not sure of the type of power  
service available, please consult your local power company.  
4.1.1. AC Powered Units  
Plug the supplied power cable into the receptacle on the CMS back panel and then connect the  
power cable to a grounded AC outlet. The AC powered version of the CMS features a self  
adjusting power supply that automatically adapts to power supplies between 90 and 250 VAC.  
4.1.2. DC Powered Units  
The DC terminal block features two bus inputs as shown in Figure 4.1 below. This allows the  
user to connect only one DC power source, or connect two DC power sources where the second  
source functions as a backup.  
When connecting the CMS to your DC power source, first remove the clear protective cover  
from the DC terminal block, attach the wires from the -48V DC power source to the screw  
terminals, connect your ground line to the labeled ground screw, and then replace the protective  
cover.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (13 of 59) [11/15/2000 10:52:02 AM]  
         
WTI CMS-16; Console Management Switch -- User's Guide  
Figure 4.1: Terminal Block Assembly (DC Units Only)  
4.2. Configure Option Switches  
When the CMS is shipped from the factory, the Option Switches are configured for 9600 baud, 8  
Bits-No Parity, RTS/CTS handshaking, verbose command response, and command echo ON (all  
switches Down). These settings are compatible with most applications. If the default settings  
are not compatible with your application, change the switch settings as follows.  
The Option Switches should be configured to match the parameters your control device will use  
when communicating with the CMS. This will ensure access to command functions, even if the  
unit is initialized to default parameters.  
Note:  
If the Option Switch configuration is changed, new parameters will not take  
effect until the unit is initialized as described in Section 4.3.  
Operating parameters (baud rate, parity, etc.) can be selected for each port  
using the /P command as described in Section 5.5. The /P command can  
select different parameters for each CMS port.  
When the CMS is initialized, parameters will return to settings specified by  
the Option Switches.  
4.2.1. Default Baud Rate (Sw1, Sw2, Sw3)  
Option Switches one through three select the default baud rate for all CMS RS232 Ports. The  
default baud rate must match the rate your control device will use when communicating with the  
CMS. If the control device will communicate via modem, select a default baud rate that is  
compatible with the modem.  
SW  
Default Baud Rate  
1
2
3
Down Down Down 9600*  
Up  
Down  
Up  
Down Down 300  
Up  
Up  
Down 1200  
Down 2400  
Down Down  
Up  
19.2K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (14 of 59) [11/15/2000 10:52:02 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
Up  
Down  
Up  
Down  
Up  
Up  
Up  
Up  
38.4K  
57.6K  
115.2K  
Up  
* = Factory Setting  
4.2.2. Default Handshake (Sw4, Sw5)  
The default handshake format must match the format your control device will use when  
communicating with the CMS. Option Switches 4 and 5 can select RTS/CTS (hardware),  
XON/XOFF, Both or None.  
Switch  
Default Handshake  
4
5
Down  
Up  
Down RTS/CTS *  
Down XON/XOFF  
Down  
Up  
Up  
Up  
Both  
None  
* = Factory Setting  
4.2.3. Default Response Message Format (Sw6)  
When commands are invoked, the CMS can respond with either verbose (English text) or terse  
(numeric / abbreviated) messages. Response messages are summarized in Section 10.2. After  
installation, the /P command can also set the response format to "none" (Quiet Mode). When  
Quiet Mode is selected, the unit will not send response messages.  
Switch 6 Default Response Message Type  
Down  
Up  
Verbose (English Text) *  
Terse (abbreviated / numeric)  
* = Factory Setting  
4.2.4. Default Command Echo (Sw7)  
Switch Seven enables or disables the Command Echo. When enabled, characters sent to the  
CMS will be echoed back to the control device.  
Switch 7  
Down  
Up  
Default Command Echo  
Enable*  
Disable  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (15 of 59) [11/15/2000 10:52:02 AM]  
     
WTI CMS-16; Console Management Switch -- User's Guide  
* = Factory Setting  
4.3. Initialize Unit to Default Settings  
If Option Switch settings are changed, new parameters will not take effect until the CMS is  
initialized.  
Caution: After initialization, the CMS will revert to the parameters specified  
by the Option Switches. Any command-selected parameters will be lost.  
1. Simultaneously press the SET and CLEAR buttons, located on the face of the CMS.  
2. Release the CLEAR button, wait for the Port LEDs to flash, and then release the SET  
button.  
4.4. Connecting Devices to the CMS  
1. Access the Command Mode.  
2. Determine which port will be used for connection to the new device (e.g. Port 3).  
3. Check Buffer: Type /S[Enter] to display the Port Status Screen. Check the "Buffer  
Count" column, which lists the amount of data stored in the buffer for each port.  
. If the Port Status Screen shows data stored in the buffer for the desired port, type  
/E xx[Enter] to clear the buffer (where xxis the desired port number).  
b. Note that cleared data cannot be recovered.  
4. Use an appropriate DB9 cable to connect the RS232 serial port on the device to a DB9  
port on the CMS.  
. External Modems and other DCE Devices: Use a standard serial modem cable.  
b. PCs and other DTE Devices: Use a standard null modem cable.  
5. Select communication parameters for each port as described in Section 5.  
4.5. Application Example  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (16 of 59) [11/15/2000 10:52:02 AM]  
     
WTI CMS-16; Console Management Switch -- User's Guide  
Figure 4.2: CMS Application Example (Not to Scale)  
The example in Figure 4.2 shows one of many possible installation configurations for the CMS.  
In this example, ports have been configured as follows:  
Network Port: The Network Port allows telnet access by remote Supervisors and/or  
Users. When a telnet connection is established, the CMS will prompt the caller to enter a  
password. If the Supervisor Password is entered, the CMS will recognize Supervisor Level  
Commands; if a Port password is entered, the CMS will only recognize User Level  
Commands. Supervisors are allowed to adjust port configuration, connect to any port, or  
review unit status. Users are only permitted to review status and connect to ports that are  
allowed by their Port password.  
Port 1 (System SetUp Port): This port has been left open in order to permit on-site  
service personnel to access the Command Mode without disrupting other ports. Since  
Port 1 is a System SetUp Port, the service tech is allowed password protected access to  
Supervisor Level commands, and is able to connect to any port, change configuration, or  
display unit status.  
Port 2 (Modem Port): An external modem has been installed at Port 2. This port has also  
been configured for Modem Mode, which allows definition of a modem reset string,  
initialization string, and hang-up string. When a caller contacts the CMS unit via modem,  
a password prompt will be displayed. If the Supervisor Password is entered, the CMS will  
permit access to Supervisor Level Commands; if a Port password is entered, the CMS will  
only recognize User Level Commands. Supervisors are allowed to adjust port  
configuration, connect to any port, or review unit status. Users are only allowed to review  
status and connect to the ports allowed by their Port Password.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (17 of 59) [11/15/2000 10:52:02 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
Ports 5, 7, and 9 (User Ports): The Port Password "COLOCATION1" has been assigned  
to these three ports. If the CMS is contacted via the Network Port or Modem Port, and this  
password is entered at log in, Users will only be able to review status and connect to the  
devices attached to Ports 5, 7, and 9.  
Ports 12, 14, and 16 (User Ports): The Port Password "COLOCATION2" has been  
assigned to these three ports. If the CMS is contacted via the Network Port or Modem  
Port, and this password is entered at log in, Users will only be able to review status and  
connect to the devices attached to Ports 12, 14, and 16.  
Note that in this example, Ports 3 through 16 could also be a mixture of ports connected to  
external modems, and ports connected to devices such as file servers or archives. This would  
allow remote users to dial in and access a specific file server or archive after entering a valid  
Port Password at log in.  
5. Configuration  
5.1. Access to the CMS Command Mode  
When the CMS Command Mode is active, commands can be invoked to select parameters, and  
connect or disconnect ports.  
Note: Command Mode cannot be accessed from a Buffer Mode Port, Passive  
Mode Port, or any port that is currently connected to another CMS port.  
1. Start your communications program (e.g. ProComm©). Make certain the CMS and  
ProComm are set for the same parameters (e.g. baud, parity, etc.).  
2. Access the Command Mode.  
. Local Access: To access the command mode from a local PC that is connected to  
the CMS via cable, press [Enter].  
i. If you have already hit other keys, press [Enter] twice. There can be no other  
characters preceding [Enter].  
ii. If the Supervisor Password has been defined, the password prompt will be  
displayed. Key in your Supervisor or Port password and press [Enter]. The  
"CMS>" prompt will appear.  
b. Modem Access: To access the command mode via modem, proceed as follows:  
i. Dial the number for the external modem connected to the CMS.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (18 of 59) [11/15/2000 10:52:02 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
ii. If you have defined the Supervisor Password, a prompt will be displayed.  
Key in your Supervisor or Port password and press [Enter]. If the Supervisor  
Password has not been defined, just press [Enter]. The "CMS>" prompt will  
appear.  
c. Network Access: In order to access the CMS command mode via network, the IP  
Address, Subnet Mask and Gateway Address must first be defined. Therefore,  
network access is not available during initial configuration.  
After Network Port Parameters are assigned as described in Section 5.5.3, the user  
may connect to the CMS via network using the following procedure:  
i. Telnet to the CMS's IP Address. For example, if the IP Address is  
"192.1.1.1", on a UNIX system, the Telnet command would be invoked as  
follows:  
$ telnet 192.1.1.1[Enter]  
ii. Note that if the Telnet connection to the CMS is refused, this probably means  
that the network port is busy, or that the IP Security feature has denied the  
connection.  
iii. If the Supervisor Password has been defined, the password prompt will be  
displayed. Key in your Supervisor or Port password and press [Enter]. The  
CMS will display the Port Status Screen, and then the "CMS>" prompt will  
appear.  
5.2. System SetUp Ports  
As discussed previously in Section 3 of this User's Guide, Ports 1 and 2 are designated as System  
SetUp Ports. Ports 1 and 2 will always permit password protected access to Supervisor Level  
command functions, even when the unit is reset to default parameters.  
In order to ensure that access to command functions is always available, Ports 1 and 2 cannot be  
configured as Buffer Mode or Passive Mode Ports. Buffer and Passive Mode Ports are not able  
to access the Command Mode. In addition, Ports 1 and 2 always permit password protected  
access to Supervisor Level commands; the Supervisor Mode cannot be disabled at these two  
ports.  
5.3. Password Functions  
The CMS features two different types of passwords; the Supervisor Password and the Port  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (19 of 59) [11/15/2000 10:52:02 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
(User) Passwords. The Supervisor Password allows system administrators to invoke unit  
configuration commands, and the Port Passwords allow users to access specific ports in order to  
create connections between ports or view port configuration parameters.  
5.3.1. The Supervisor Password  
The Supervisor Password allows access to higher level CMS configuration commands, which  
administrators can employ to select communication parameters, set up IP Security, assign port  
access rights, and perform other system management tasks.  
When the Supervisor Password is defined (via the System Parameters menu), the CMS will  
display a password prompt whenever you attempt to access the command mode. If the correct  
Supervisor Password is entered, the CMS command mode then starts up in Supervisor Mode.  
Supervisor Level commands are summarized in Section 10.3 of this User's Guide.  
Note:  
If the Supervisor Password is not defined, then Supervisor Level commands  
will be available to all ports, and port access and configuration functions will  
not be password protected.  
If you wish to restrict user ports from changing CMS configuration  
parameters or connecting to restricted ports, the Supervisor Password must be  
defined.  
When the Supervisor Password is defined, the CMS will display a password  
prompt when you attempt to access the command mode. Any RS232 port that  
has not been assigned a Port Password, can then only be accessed using the  
Supervisor Password.  
Normally, the Supervisor Password can be entered at any port in order to gain access to  
Supervisor Level commands. Note that if you wish to completely deny a port's access to  
Supervisor Mode (even with the Supervisor Password), the Port Parameters menus (/P and /N)  
can be used to disable the Supervisor Mode at ports 3 through 16 and the Network Port. The  
Supervisor Mode cannot be disabled at System SetUp Ports 1 and 2.  
Note that if the unit is reset to default parameters, all ports will revert to the default state, where  
Supervisor Level commands are available to all ports, without password protection.  
Note:  
When defining a Supervisor Password, it is strongly recommended that you  
record the password for future use.  
If you forget or lose your Supervisor Password, you will not be able to access  
Supervisor Level Commands. In this case, the only way to access the  
Supervisor Mode, is to reinitialize the CMS to default values as described in  
5.3.2. The Port Passwords  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (20 of 59) [11/15/2000 10:52:02 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
The Port Passwords (or User Passwords) allow system administrators to restrict access to a  
specific group of ports. When the CMS command mode is accessed with a Port Password, users  
may only connect to the RS232 Ports to which they have been granted access, and review  
configuration parameters for those ports. Port Passwords do not grant access to CMS  
configuration commands.  
The configuration menus (/P) for each RS232 port allow a Port Password to be assigned to each  
individual port. In order to allow a Port Password to grant access to a series of CMS ports, the  
same Port Password is assigned to each port in the series.  
For example, if the Port Password "test" is assigned to ports 3, 4, and 5, then when "test" is  
entered at the Password Prompt, the user will only be able to connect to ports 3, 4, and 5, and  
will only be able to view parameters for ports 3, 4, and 5.  
If desired, all CMS ports can function as both a Supervisor Port and a User Port, depending on  
which password is entered at the login prompt. However, if you wish to prevent a port from  
being able to access the Supervisor Mode at all (even with the Supervisor Password), the  
Supervisor Mode can be disabled at the RS232 Ports and the Network Port using the Port  
Configuration menus as described in Section 5.5. Note however, that the Supervisor Mode  
cannot be disabled at Ports 1 and 2; these ports are designated as SetUp Ports, and are always  
allowed password protected access to Supervisor Level commands.  
5.4. Defining the Site ID and Supervisor Password  
Before configuring individual ports, the Site ID and Supervisor Password should be defined. The  
Site ID can be used to indicate the location or name of the CMS unit, and the Supervisor  
Password is used to restrict access to sensitive command functions. Both the Site ID message  
and Supervisor Password are defined via the System Parameters menu (/F).  
Note:  
The Site ID cannot include double quotes.  
The Supervisor Password cannot include an asterisk, forward slash, spaces, or  
double quotes.  
Both the Site ID and Supervisor Password will be cleared if the CMS is  
initialized to default settings.  
The System Parameters Menu is only available in Supervisor Mode.  
1. Access the Command Mode. When the "CMS>" prompt appears, type /F [Enter] to  
display the System Parameters Menu.  
2. Site ID Message: (Up to 32 characters; Default = undefined) Type 1and press [Enter],  
the Site I.D. Prompt will appear. Key in the desired text and press [Enter] . To display the  
Site I.D., type /J [Enter]. The Site ID is also listed on the Port Status and Port  
Diagnostic Screens.  
3. Supervisor Password: (Up to 32 characters; Default = undefined) Type 2and press  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (21 of 59) [11/15/2000 10:52:02 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
[Enter], a prompt will appear. Key in the desired password then press [Enter], the CMS  
will prompt you to re-key the password in order to confirm spelling and capitalization.  
Key in the password a second time, and then press [Enter].  
Note:  
The Supervisor Password is case sensitive. Make certain to note the exact  
password entered, including the case of each letter.  
Make certain to write down your Supervisor Password. If the password is lost  
or forgotten, you will not be able to access Supervisor Level commands  
unless you initialize the unit and clear all parameters as described in  
5.5. Port Configuration  
5.5.1. Configuration Conventions  
When responding to prompts, invoking commands, and selecting items from the port  
configuration menus, note the following:  
To select an item from a Port Configuration menu, key in the number for the item and  
press [Enter].  
To clear an item in a Port Configuration menu, enter the number for the desired item and  
press [Enter]. When the prompt appears, press [Space] and then press [Enter].  
When defining the Port Name, do not use the forward slash character (/), double quotes  
("), the asterisk character (*), or blank spaces.  
Port Names cannot begin with a number.  
A Port cannot be named "N", this name is reserved for the Network Port.  
Refer to the instructions in each screen for additional functions available under that  
screen.  
To exit a menu or prompt without changing its current value, press [Esc].  
Passwords and port names are case sensitive. When defining passwords and port names,  
note the exact text, including the case of each character.  
The "Who" command (/W) can be used to display currently selected parameters for your  
resident port. Note that when the Network port has been accessed using a Port Password  
(User Mode), the /W command will only display the selected Logoff Character.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (22 of 59) [11/15/2000 10:52:02 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
5.5.2. Port Modes  
The CMS offers four different port operation modes; Any-to-Any Mode, Passive Mode, Buffer  
Mode, and Modem Mode. The Port Modes function as follows:  
Any-to-Any Mode: Allows communication between connected ports. Any-to-Any Mode  
Ports can be connected to other Any-to-Any Mode, Passive Mode, Buffer Mode, or  
Modem Mode Ports by accessing Command Mode and invoking the /C command (see  
Section 7.1.1). The Any-to-Any Mode is available to all ports.  
Passive Mode: Allows communication between connected ports, but does not allow  
access to Command Mode. Passive Mode Ports can be connected by accessing Command  
Mode from a free Any-to-Any or Modem Mode port and invoking the /C command (see  
Section 7.1.1). The Passive Mode is not available to Ports 1 or 2 or the Network Port.  
Buffer Mode: Allows collection and storage of data received from connected devices.  
Collected data can be retrieved by accessing Command Mode from a free Any-to-Any or  
Modem Mode Port, and issuing the Connect (/C) Command. Note that the Buffer Mode  
also allows pass-through communication with the connected device. The Buffer Mode is  
not available to Ports 1 or 2 or the Network Port.  
Modem Mode: Allows communication between connected ports and simplifies  
connection to an external modem. A port configured for the Modem Mode can perform all  
functions normally available in Any-to-Any Mode. The Modem Mode also allows  
definition of a Hang-Up String, Reset String, and Initialization String. Any CMS RS232  
port can be configured for the Modem Mode. The Modem Mode is not available at the  
Network Port.  
For more information on Port Modes, please refer to Section 7.  
5.5.3. RS232 Port Configuration Menus  
The Port Configuration Menus are used to select options for each of the CMS RS232 ports.  
Parameters selected via these menus will stay in effect until the unit is initialized or the /P  
command is used to reconfigure the port. After initialization, parameters will revert to the  
defaults specified by the Option Switches.  
To select port parameters, proceed as follows:  
1. Access the Command Mode. If the password prompt is displayed, key in your Supervisor  
Level Password.  
2. Type /P, followed by the number of the port to be configured, and press [Enter]. For  
example, to configure Port 2, type /P 2 [Enter]. The Port Configuration menu will  
appear (Figure 5.1).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (23 of 59) [11/15/2000 10:52:02 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
. If the /P Command is entered without the port number (e.g. /P[Enter]), the  
configuration menu for your resident port will be displayed.  
b. The /P command is only available in the Supervisor Mode  
PORT PARAMETERS #02  
1. Port Name:  
2. Password:  
3. Baud Rate:  
(undefined)  
(undefined)  
9600  
4. Bits/Parity:  
5. Stop Bits:  
6. Handshake Mode:  
7. Port Mode:  
74. DTR Output:  
8. Supervisor Mode:  
9. Logoff Character:  
8-None  
1
CTS/RTS  
Any-to-Any  
Pulse  
Permit  
+
10. Sequence Disconnect: Three Characters  
11. Timeout Disconnect: Off  
12. Response Type:  
13. Command Echo:  
14. Accept Break:  
Verbose  
On  
Yes  
Enter: "<" Previous Port,  
">" Next Port,  
<ESC> Exit ...  
Figure 5.1: Port Configuration Menu (Port 2 Shown)  
The Port Configuration menu offers the following options:  
1. Port Name: (Up to 16 characters) Assigns a name to the port. (Default = undefined).  
2. Password: (Up to 16 characters) Defines the Port Password for this port. Note that  
identical Port Passwords are generally assigned to several ports. When this password is  
entered at the login prompt, the user will then have access to all ports that share this  
password. (Default = undefined).  
Note: The Port Password is not displayed by the Port Parameters menu. When the  
Port Password has been defined, the field for this item will read "defined". To  
display Port Passwords, invoke the /SP or /WP commands as described in Section 6.  
3. Baud Rate: Selects the baud rate for the port. Can be set to any standard rate from  
300 bps to 115.2K bps. (Default = Selected By Option Switches 1, 2, and 3)  
4. Bits/Parity: (Default = 8-None).  
5. Stop Bits: (Default = 1).  
6. Handshake Mode: Selects the handshake format for this port; XON/XOFF, RTS/CTS  
(hardware), Both, or None. (Default = RTS/CTS).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (24 of 59) [11/15/2000 10:52:02 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
7. Port Mode: Defines the operation mode for this port. Note that Ports 1 and 2 cannot  
be configured for Passive Mode or Buffer Mode. (Default = Any-to-Any Mode).  
When Any-to-Any, Passive, or Buffer Mode is selected, the unit will display the DTR  
Output prompt as shown in Figure 5.1. The DTR Output prompt is not displayed when  
Modem Mode is selected.  
74. DTR Output: Determines how the DTR line will react when this port  
disconnects. The DTR line can be held low, held high, or pulsed for 0.5 seconds and  
then held high. In the default state, the DTR line will pulse for 0.5 seconds and then  
remain high. For more information on DCD and DTR hardware lines, please refer  
to Appendix A. (Default = Pulse).  
PORT PARAMETERS #02  
1. Port Name:  
2. Password:  
3. Baud Rate:  
(undefined)  
(undefined)  
9600  
4. Bits/Parity:  
5. Stop Bits:  
6. Handshake Mode:  
7. Port Mode:  
8-None  
1
CTS/RTS  
Modem  
71. Reset String:  
72. Init String:  
ATZ  
AT&C1&D2S0=1  
73. Hang-Up String: (undefined)  
8. Supervisor Mode:  
9. Logoff Character:  
Permit  
+
10. Sequence Disconnect: Three Characters  
11. Timeout Disconnect: Off  
12. Response Type:  
13. Command Echo:  
14. Accept Break:  
Verbose  
On  
Yes  
Enter: "<" Previous Port,  
">" Next Port,  
<ESC> Exit ...  
Figure 5.2: Port Configuration Menu (Modem Mode)  
When Port Mode (menu Item 7) is set to Modem Mode, the menu will include additional  
prompts (see Figure 5.2), which are used to define the following:  
71. Reset String: If necessary, this prompt can be used to re-define the modem  
reset string. The Reset String is sent prior to the Initialization string in order to  
select common initial parameters. (Default = ATZ).  
72. Initialization String: Defines a command string that is sent after the Reset  
String to initialize a modem to settings required by your application. (Default =  
AT&C1$D2S0=1).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (25 of 59) [11/15/2000 10:52:02 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
73. Hang-Up String: Defines the modem hang-up message. Although the CMS  
will pulse the DTR line in order to hang-up an attached modem, the Hang-Up string  
is often useful for controlling modems that do not use the DTR line. (Default =  
undefined).  
8. Supervisor Mode: Permits or denies port access to Supervisor Mode. When this item  
is enabled (Permit), and the valid Supervisor Password is entered, the port will be allowed  
to invoke Supervisor Level commands. If this item is disabled (Deny), the port may not  
enter Supervisor Mode, even when the Supervisor Password is entered. (Default =  
Permit).  
9. Logoff Character: Defines the Logoff Character for this port. The Logoff Character  
determines the command sequence that must be issued at this port in order to disconnect  
from a second port (Resident Disconnect). Note the following:  
The default Logoff Character is "+". As a result, the default Resident Disconnect  
Sequence is [Enter]+++[Enter].  
The default three character Resident Disconnect Sequence uses the format  
"[Enter]LLL[Enter]", where L is the Logoff Character. If the one character  
disconnect is selected (see item 10), a resident connection is terminated by simply  
typing the Logoff Character once (without carriage returns).  
10. Sequence Disconnect: Enables/Disables and configures the Resident Disconnect  
command. This prompt offers the option to either disable the Sequence Disconnect, select  
a three character format, or select a one character format. (Default = Three Characters).  
Note the following:  
When a Resident Connection is initiated, the CMS will send a message which lists  
the connected ports, and displays the one character or three character disconnect  
command that will be required in order to terminate the connection.  
The One Character Disconnect sequence is intended for situations where the  
destination port should not receive the disconnect command. When the Three  
Character format is selected, the disconnect sequence will pass through to the  
destination port prior to breaking the connection.  
When the Three Character format is selected, the Resident Disconnect Sequence  
will use the format "[Enter]LLL[Enter]", where L is the selected Logoff Character.  
When the One Character format is selected, resident connections are terminated by  
entering the selected Logoff Character only. There is no need to press [Enter]  
before and after the Logoff Character when the One Character format is selected.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (26 of 59) [11/15/2000 10:52:02 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
11. Timeout Disconnect: Enables and selects the Timeout Period for this port. If  
enabled, and the port does not receive or transmit data for the specified Timeout Period,  
the port will disconnect. When the port is set for Any-to-Any Mode, Passive Mode, or  
Buffer Mode, the default setting for this item is "OFF". When the port is set for Modem  
Mode, the default setting for this item is 15 minutes.  
12. Response Type: Selects the type of messages that this port will send in response to  
commands. The user can select Verbose (English Text), Terse (Numeric / Abbreviation),  
or Quiet Mode (No Response). (Default = Verbose).  
13. Command Echo: Enables or Disables the command echo for this port. (Default =  
On).  
14. Accept Break: Determines whether the port will accept breaks received from the  
attached device, and pass them along to a connected port. When enabled, breaks received  
at this port will be passed to any port that this port is connected to, and sent along to the  
device connected to the other port. When disabled, breaks will be refused at this port, and  
hence, not sent to the other port. (Default = Yes)  
5.5.4. Network Port Configuration Menu  
In order to communicate with the CMS via network, the IP Address, Subnet Mask, and Gateway  
Address must first be defined using the Network Parameters Menu. If desired, the Network  
Parameters menu also allows you to implement IP Security features, which can restrict command  
mode access based on the user's IP Address.  
Settings for network parameters depend on the configuration of your individual network. Please  
contact your network administrator for appropriate settings, and then assign parameters as  
described in this section.  
NETWORK PARAMETERS  
1. IP Address:  
2. Subnet Mask:  
3. Gateway Address:  
4. IP Security:  
(undefined)  
(undefined)  
(undefined)  
Off  
TELNET PORT PARAMETERS  
11. Port Name:  
12. Supervisor Mode:  
13. Logoff Character:  
(undefined)  
Permit  
+
14. Sequence Disconnect: Three Characters  
15. Timeout Disconnect: 5 Min  
16. Response Type:  
17. Command Echo:  
18. Accept Break:  
Verbose  
On  
Yes  
Enter: #<CR> to Change,  
<ESC> Exit ...  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (27 of 59) [11/15/2000 10:52:03 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
Figure 5.3: Network Parameters Menu (Supervisor Mode Only)  
To access the Network Parameters menu, type /Nand press [Enter]. The screen shown in  
Figure 5.3 will be displayed. Note that the Network Parameters menu is only available in  
Supervisor Mode. The Network Parameters menu offers the following options:  
1. IP Address: Defines the IP Address for the CMS unit. Type 1press [Enter], and follow  
the instructions in the submenu. (Default = undefined).  
2. Subnet Mask: Defines the Subnet Mask for the CMS unit. Type 2press [Enter], and  
follow the instructions in the submenu. (Default = undefined).  
3. Gateway Address: Defines the Gateway Address for the CMS unit. Type 3press  
[Enter], and follow the instructions in the submenu. (Default = undefined).  
4. IP Security: Sets up the IP Security feature as described in Section 5.5.5.  
11. Port Name: (Up to 16 characters) Assigns a name to the Network Port. (Default =  
undefined).  
12. Supervisor Mode: Permits or denies access to the Supervisor Mode. When enabled  
(Permit), and the valid Supervisor Password is entered, this port may then issue  
Supervisor level commands. If disabled (Deny), the port may not enter Supervisor Mode,  
even when the Supervisor Password is entered. (Default = Permit).  
13. Logoff Character: Defines the Logoff Character for the Network Port. The Logoff  
Character determines the disconnect sequence that is issued at this port in order to  
disconnect from a second port (Resident Disconnect). When defining the Logofff  
Character, note the following:  
The default Logoff Character is "+". As a result, the default Resident Disconnect  
Sequence is [Enter]+++[Enter].  
The default three character Resident Disconnect Sequence uses the format  
[Enter]LLL[Enter], where Lis the Logoff Character. If the one character  
disconnect is selected (see item 14), a resident connection is terminated by simply  
typing the Logoff Character once (without carriage returns)  
14. Sequence Disconnect: Enables/Disables and configures the Resident Disconnect  
command. This prompt offers the option to either disable the Sequence Disconnect, select  
a three character format, or a one character format. (Default = Three Characters). Note the  
following:  
When a Resident Connection is initiated, the CMS will send a message which lists  
connected ports, and displays the one character or three character disconnect  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (28 of 59) [11/15/2000 10:52:03 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
command that will be required in order to terminate the connection.  
The One Character Disconnect is intended for situations where the destination port  
should not receive the disconnect command. When the Three Character format is  
selected, the disconnect sequence will pass through to the destination port prior to  
breaking the connection.  
When Three Character format is selected, the Resident Disconnect uses the format  
"[Enter]LLL[Enter]", where Lis the selected Logoff Character.  
When the One Character format is selected, resident connections are terminated by  
entering the selected Logoff Character only. There is no need to press [Enter]  
before and after the Logoff Character when the One Character format is selected.  
15. Timeout Disconnect: Enables and selects the Timeout Disconnect for the Network Port.  
If enabled, and the port does not receive or transmit data for the specified time period, the  
port will disconnect. (Default = 5 Minutes).  
16. Response Type: Selects the type of messages that the port will send in response to  
commands. The user can select Verbose (English Text), Terse (Numeric / Abbreviation),  
or Quiet Mode (No Response). (Default = Verbose).  
17. Command Echo: Enables or Disables the command echo for the Network Port. (Default  
= On).  
18. Accept Break: Determines whether the port will accept breaks received from the  
attached device, and pass them along to a connected port. When enabled, breaks received  
at this port will be passed to any port that this port is connected to, and sent along to the  
device connected to the other port. When disabled, breaks will be refused at this port.  
(Default = Yes).  
5.5.5. Implementing IP Security  
The CMS can be configured to restrict unauthorized IP addresses from Telneting to the unit.  
This allows the user to grant Telnet access to only a specific group of IP addresses, or block a  
particular IP address from gaining access. In the default state, the CMS accepts incoming IP  
connections from all hosts. To configure the IP Security feature, proceed as follows:  
Note: In the default state, the CMS will allow all IP addresses to Telnet to the unit.  
1. Access the Network Parameters menu as described in Section 5.5.4. Note that the Network  
Parameters menu is only available in Supervisor Mode.  
2. When the Network Parameters menu appears, type 4 and press [Enter] to access the IP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (29 of 59) [11/15/2000 10:52:03 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
Security menu (Figure 5.4).  
IP SECURITY:  
1. Security Mask #1: (undefined)  
2. Mask #1 Action: Permit  
3. Security Mask #2: (undefined)  
4. Mask #2 Action: Permit  
5. Security Mask #3: (undefined)  
6. Mask #3 Action: Permit  
7. Security Mask #4: (undefined)  
8. Mask #4 Action: Permit  
9. Security Mask #5: (undefined)  
10. Mask #5 Action: Permit  
Enter: #<CR> to Select Menu,  
<ESC> for Previous Menu ...  
Figure 5.4: IP Security Menu  
3. The IP Security Menu lists five IP Security "masks" along with the selected permit/deny  
action for each mask.  
. Each Security Mask prompt is used to define a specific IP address or range of IP  
addresses. Each Mask Action prompt is used to select the permit/deny action for the  
corresponding mask.  
b. Masks are listed in order of ascending priority; Mask 1 has the lowest priority, and  
Mask 5 has the highest priority.  
c. Masks have a cumulative effect; high priority masks supersede the effect of lower  
priority masks.  
d. Each IP Address consists of a series of four eight bit numbers. The number 255 is  
used as a wild card.  
Example 1: Deny access to all hosts except 192.1.1.5:  
Security Mask #1: 255.255.255.255  
Mask #1 Action: Deny  
Security Mask #2: 192.1.1.5  
Mask #2 Action: Permit  
Since 255 is a wild card, Mask #1 blocks all IP Addresses. Mask #2 then specifically grants  
access to 192.1.1.5 only.  
Example 2: Allow access only by addresses that begin with 192:  
Security Mask #1: 255.255.255.255  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (30 of 59) [11/15/2000 10:52:03 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
Mask #1 Action: Deny  
Security Mask #2: 192.255.255.255  
Mask #2 Action: Permit  
Since 255 is a wild card, Mask #1 blocks all IP addresses Mask #2 then grants access to all  
addresses that begin with 192.  
Example 3: Allow access only by addresses that begin with 192, deny access to 192.1.1.5.  
Security Mask #1: 255.255.255.255  
Mask #1 Action: Deny  
Security Mask #2: 192.255.255.255  
Mask #2 Action: Permit  
Security Mask #3: 192.1.1.5  
Mask #3 Action: Deny  
Since 255 is a wild card, Mask #1 blocks all IP addresses. Mask #2 then grants access to all  
addresses that begin with 192. Finally, Mask #3 specifically blocks access by 192.1.1.5.  
Note:  
Mask #5 has priority over the four other masks. If Mask #5 is set to deny  
access by "255.255.255.255" (all wild cards), all IP addresses will be  
blocked, and you will not be able to access the CMS Command Mode via  
network. Access will only be allowed via the Console Port or Modem Port.  
When using the wild card address "255.255.255.255" to block access by all  
IP addresses, make certain that at least one higher priority mask permits  
access by your IP address.  
5.6. Copying Parameters to All Ports  
The /CP command (Copy Port Parameters) provides a convenient means for selecting identical  
(or similar) parameters for all CMS RS-232 ports.  
When the /CP command is invoked, the unit will display a menu which allows you to select port  
communication parameters, and then copy them to all CMS RS-232 ports. The Copy Port  
Parameters menu can be used to set all parameters for all RS-232 Ports, or define only a select  
group of parameters and then copy them to all ports.  
Note:  
The /CP command will not copy parameters to the Network Port.  
The /CP command is only available in Supervisor Mode.  
The Copy Port Parameters Menu will not display the Port Password. This  
field will read either "undefined" or "defined", depending upon whether or  
not the Port Password has been specified.  
To select common parameters for all CMS RS-232 ports, proceed as follows:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (31 of 59) [11/15/2000 10:52:03 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
1. Access the CMS command mode. If the password prompt is displayed, key in your  
Supervisor Level Password.  
2. At the command prompt, type /CPand press [Enter], the menu shown in Figure 5.5 will  
be displayed.  
COPY PORT PARAMETERS:  
1. Port Name:  
2. Password:  
(undefined)  
3. Baud Rate:  
4. Bits/Parity:  
5. Stop Bits:  
6. Handshake Mode:  
7. Port Mode:  
74. DTR Output:  
8. Supervisor Mode:  
9. Logoff Character:  
10. Sequence Disconnect:  
11. Timeout Disconnect:  
12. Response Type:  
13. Command Echo:  
14. Accept Break:  
(Note: Ports 1 & 2 will NOT have restricted values changed.)  
Enter: Parameter # <CR> to define parameter value to copy to all  
ports,  
-<CR> to remove all values set,  
X<CR> to exit WITHOUT copy,  
<ESC> to copy to all ports and exit ...  
Figure 5.5: The Copy Port Parameters Menu  
3. Selecting Parameters: To select parameters to be copied, key in the number for the  
desired parameter, press [Enter], and then follow the instructions in the submenu. Note  
that it is not necessary to define all port parameters, for example, the /CP command could  
be used to select only the Baud Rate for all ports.  
Note: The /CP command will only copy the parameters that are currently  
displayed by the Copy Port Parameters menu. Note that although the Port Password  
is not displayed, the selected password will be copied if the field for this item reads  
"defined".  
4. Clear Menu: After defining several parameters, if you wish to clear the /CP menu and  
start again, type -(dash) and press [Enter], the menu will be reset.  
5. Copy Parameters: When you have finished selecting parameters, press [Esc] to copy the  
selected parameters to all CMS RS-232 Ports and exit from the Copy Port Parameters  
menu.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (32 of 59) [11/15/2000 10:52:03 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
5.7. Save User Selected Parameters  
Although this step is optional, it is strongly recommended to save all user- defined parameters to  
an ASCII file. This will allow quick recovery in the event of accidental deletion or  
reconfiguration of port parameters. Section 8 describes the procedure for saving configuration  
parameters to an ASCII file.  
6. The Status Screens  
The CMS Status Screens display the connection status and communication parameters for the  
sixteen RS-232 ports and the Network Port. There are four different types of status screens; The  
Port Status Screen (/S), the Port Diagnostics Screen (/SD), the Network Status Screen (/SN), and  
the Port Parameters Screens (/W).  
6.1. The Port Status Screen (/S)  
The Port Status Screen lists the general status of the CMS's  
RS-232 ports. To display the Port Status Screen, access the command mode and type /S  
[Enter], the screen will appear as shown in Figure 6.1.  
Although both Supervisors and Users can display the Port Status Screen, the screen will appear  
slightly different, depending upon whether the command mode was accessed with the Supervisor  
Password or a Port Password. When a Port Password (User Mode) is entered at login, the Port  
Status Screen will only display the status of those ports that share the same Port Password that  
was entered at login.  
When the Supervisor Mode is active, the Port Status Screen offers the option to either display or  
suppress Port Passwords. Normally, when the /S command is invoked, the Password column will  
read either "defined" or "undefined", depending upon whether or not the password for each port  
has been specified. To display the Port Status Screen with Port Passwords included, type /SP  
and then press [Enter]. Note that the /SP command option is not available in User Mode.  
PORT STATUS: Version 1.02, Site ID: (undefined)  
PORT |  
NAME  
|
PASSWORD  
| STATUS | MODE | BUFFER COUNT  
-----+------------------+------------------+--------+------+--------------  
01 | (undefined)  
02 | (undefined)  
03 | (undefined)  
04 | (undefined)  
05 | (undefined)  
06 | (undefined)  
07 | (undefined)  
08 | (undefined)  
|
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
|
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
0
0
0
0
0
0
0
0
|
|
|
09 | (undefined)  
10 | (undefined)  
11 | (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
| Free | Any |  
| Free | Any |  
| Free | Any |  
0
0
0
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (33 of 59) [11/15/2000 10:52:03 AM]  
       
WTI CMS-16; Console Management Switch -- User's Guide  
12 | (undefined)  
13 | (undefined)  
14 | (undefined)  
15 | (undefined)  
16 | (undefined)  
| (undefined)  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
| Free | Any |  
0
0
0
0
0
| (undefined)  
| (undefined)  
| (undefined)  
| (undefined)  
Enter /H for Command Menu  
Figure 6.1: The Port Status Screen (Supervisor Mode, Defaults Shown)  
As shown in Figure 6.1, The Port Status Screen lists the following items:  
Name: The user-defined name for each port.  
Password: The user-defined password for each port. Note that actual passwords are not  
displayed; this column will read either "undefined" or "defined". To display Port  
Passwords, type /SP[Enter] (Supervisor Mode Only).  
Status: The connect status of each port. When the port is connected, this column will list  
the number of the other CMS port connected to this port. An "N" indicates that this port is  
currently connected to the CMS Network Port.  
Mode: The user-selected Port Mode. This column will read Any (Any-to-Any), Modem,  
Passive, or Buffer, depending on the configuration selected for the port.  
Buffer Count: Lists the amount of data (in bytes) stored in the buffer for this port.  
6.2. The Port Diagnostics Screen (/SD)  
The Port Diagnostics Screen provides more detailed information about each port, including the  
port name and communication parameters. To display the Port Diagnostics Screen, access the  
command mode and type /SD[Enter], the screen will appear as shown in Figure 6.2.  
Like the Port Status Screen, the Port Diagnostics Screen is also available to both Supervisors and  
Users, and will appear slightly differently, depending upon whether the command mode was  
accessed with the Supervisor Password or a Port Password (User Mode).  
In User Mode, the Port Diagnostics Screen will display only the status of those ports that share  
the same Port Password that was entered at login. Ports that are protected by other passwords  
will not be displayed.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (34 of 59) [11/15/2000 10:52:03 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
PORT DIAGNOSTICS: Version 1.02 Site ID: (undefined)  
PORT |  
NAME  
| STATUS | BAUD | COM | HS | MODE | BUF | CTS  
-----+------------------+--------+------+-----+-----+------+-----+-----  
01+ | (undefined)  
02+ | (undefined)  
03+ | (undefined)  
04+ | (undefined)  
05+ | (undefined)  
06+ | (undefined)  
07+ | (undefined)  
08+ | (undefined)  
|
09+ | (undefined)  
10+ | (undefined)  
11+ | (undefined)  
12+ | (undefined)  
13+ | (undefined)  
14+ | (undefined)  
15+ | (undefined)  
16+ | (undefined)  
| *Free | 9600 | 8N1 | RTS | Any | 0 | H  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
|
|
|
|
|
|
|
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
| *Free | 9600 | 8N1 | RTS | Any | 0 | L  
Enter /H for Command Menu  
Figure 6.2: The Port Diagnostics Screen (Defaults Shown)  
As shown in Figure 6.2, the Port Diagnostics Screen lists the following items:  
Port: The Port Number. Note that if this column contains a plus sign (+), this indicates  
that the port will be allowed to access the Supervisor Mode if the appropriate Supervisor  
Password is entered at login.  
Name: The user-defined name for each port.  
Status: The connect status for each port. When the port is connected, this column will list  
the number of the other port that is connected to this port. Note that if this column  
contains an asterisk, this indicates that the port has accessed the Command Mode.  
Baud: The baud rate selected for each port.  
COM: The Data Bits, Parity, and Stop Bits selected for each port. For example, "8N1"  
indicates Eight data bits, No parity, and One stop bit.  
HS: The handshaking (flow control) mode for each port.  
Mode: The user-selected Port Mode. This column will read Any (Any-to-Any), Modem,  
Passive, or Buffer, depending on the configuration selected for each port.  
BUF: Lists the amount of data (in bytes) currently stored in the buffer for this port.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (35 of 59) [11/15/2000 10:52:03 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
CTS: The High/Low status of the CTS line at the RS232 interface.  
6.3. The Network Status Screen (/SN)  
This screen lists general parameters for the Network Port. To display the Network Status Screen  
(Figure 6.3), type /SNand press [Enter].  
Note that the Network Status Screen is only available in Supervisor Mode. When the user has  
logged on with a Port Password, the /SN command will return an "invalid" message.  
NETWORK STATUS  
LAN STATUS  
NIC Installed:  
MAC Address:  
Yes  
00-40-05-6d-a3-ed  
TELNET PORT STATUS  
Name:  
(undefined)  
Telnet Connection: No  
Port Connection: Free  
Buffer Count:  
0
CMS>  
Figure 6.3: The Network Status Screen (Defaults Shown)  
As shown in Figure 6.3, the Network Status Screen lists the following information:  
NIC Installed: If your CMS unit includes a Network Card, this item will read "Yes".  
MAC Address: The permanent physical address assigned to the Network Card  
Name: The user-defined name for the Network Port.  
Telnet Connection: This item will read "Yes" when a remote user is connected to the  
Network Port via telnet.  
Port Connection: The connect status of the Network Port. When the Network Port is  
connected to an RS232 port, this item will list the number of the RS232 port. If the  
Network port is not connected to another port, this item will read "Free".  
Buffer Count: Lists the amount of data (in bytes) stored in the buffer for this port.  
6.4. The Port Parameters Screens (/W)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (36 of 59) [11/15/2000 10:52:03 AM]  
     
WTI CMS-16; Console Management Switch -- User's Guide  
The /W command displays more detailed information about an individual CMS port. Rather than  
listing connection information for all ports like the Port Status Screens, the Port Parameters  
screen lists all defined parameters for a specific port.  
PORT PARAMETERS #03:  
1. Port Name:  
2. Password:  
3. Baud Rate:  
(undefined)  
(undefined)  
9600  
4. Bits/Parity:  
5. Stop Bits:  
6. Handshake Mode:  
7. Port Mode:  
74. DTR Output:  
8. Supervisor Mode:  
9. Logoff Character:  
8-None  
1
RTS/CTS  
Any-to-Any  
Pulse  
Permit  
+
10. Sequence Disconnect: Three Characters  
11. Timeout Disconnect:  
12. Response Type:  
13. Command Echo:  
Off  
Verbose  
On  
14. Accept Break:  
Yes  
Enter: "<" previous port,  
">" next port,  
<ESC> exit ...  
Figure 6.4: The Port Parameters Screen (RS232 Port Shown)  
The /W command is available in both Supervisor Mode and User Mode. Note however, that  
when you log in with a Port (User) password, the CMS will only display information regarding  
your resident port.  
When the Supervisor Mode is active, the Port Parameters Screens offer the option to either  
display or suppress the Port Passwords. Normally, when the /W command is invoked, the  
Password field will read either "defined" or "undefined", depending upon whether or not the  
password for that port has been specified. To display the Port Parameters Screen with the Port  
Password, type /WP, followed by the desired port number, and then press [Enter]. Note that the  
/WP command option is not available in User Mode.  
The /W command uses the following format:  
/W[P] xx[Enter]  
Where:  
P
Is the command option to display port passwords. Note that when  
this option is included (e.g. /WP 5), the Port Parameters Screen  
will display the Port Password, if defined. (Supervisor Mode Only).  
xx  
is the desired port number. If the letter "N" is entered in place of a  
port number, the /W command will display parameters for the  
Network Port.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (37 of 59) [11/15/2000 10:52:03 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
Note: When the command mode is accessed via the Network Port using a Port  
(User) password, the /W command will only display the Sequence Disconnect,  
Logoff Character, and the status of the Accept Break item.  
7. Operation  
7.1. Any-to-Any Mode  
Any-to-Any Mode Ports can be connected to other Any-to-Any, Passive, Buffer, or Modem  
Mode Ports by accessing Command Mode and issuing the /C Command. All ports can be  
configured for the Any-to-Any Mode. Note that the Network Port is always configured for  
Any-to-Any Mode.  
7.1.1. Port Connection and Disconnection  
The CMS provides communication between devices without the requirement that both devices  
use the same communication parameters. This allows you to connect devices that use dissimilar  
baud rates, parity, handshake, and etc.. The CMS converts data rates and other parameters,  
eliminating the need to select common parameters for all connected devices.  
7.1.1.1. Connecting Ports  
Two different types of connections can be made between CMS ports; Resident Connections and  
Third Party Connections.  
Resident Connections: Your resident port issues a /C command to connect to a second  
port. For example, Port 4 issues the /C command to connect to Port 5.  
Third Party Connections: (Supervisor Mode Only) Your resident port issues a /C  
command to create a connection between two other ports. For example, Port 1 is your  
resident port, and Port 1 issues a command to connect Port 2 to Port 3.  
Note:  
Third Party Connections can only be initiated from a port with Supervisor  
Level command capability.  
The RS232 Ports cannot initiate a connection to the Network Port.  
If a port has accessed Command Mode using the Port Password (User Mode),  
then that port will only be able to connect to other ports that share the same  
port password.  
To Connect ports, proceed as follows:  
1. Access the Command Mode. If the Password Prompt is displayed, enter your Supervisor  
or Port Password.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (38 of 59) [11/15/2000 10:52:03 AM]  
       
WTI CMS-16; Console Management Switch -- User's Guide  
2. Invoke the /Ccommand to connect the desired ports.  
. Resident Connect: To connect your resident port to another port, type /C xx  
[Enter]. Where xxis the number or name of the port you want to connect. The  
CMS will display the numbers of the connected ports, along with the command  
sequence that will be required in order to disconnect the two ports.  
Example: To connect your resident port to Port 8, type /C 8 [Enter].  
b. Third Party Connect: (Supervisor Mode Only) To connect any two ports (other  
than your resident port), type /C xx XX [Enter]. Where xx and XXare two port  
names or numbers. The CMS will display the numbers of the two connected ports.  
Example: To connect Port 5 to Port 6, invoke the following command at a port  
with Supervisor Level command capability: /C 5 6 [Enter].  
Note:  
Resident Connections: RS232 Ports are not allowed to initiate a Resident  
Connection to the Network Port.  
Third Party Connections: RS232 Ports are not allowed to connect another  
port to the network port. For example, Port 1 is not allowed to connect Port 3  
to the Network Port.  
When the /C command specifies the port name, it is only necessary to enter enough letters to  
differentiate the desired port from other ports. Type an asterisk (*) to represent the remaining  
characters in the port name. For example, to connect your resident port to a port named  
"SALES", the connect command can be invoked as /C S*, providing no other port names begin  
with the letter "S".  
7.1.1.2. Disconnecting Ports  
There are three different methods for disconnecting ports, the Resident Disconnect, the Third  
Party Disconnect, and the No Activity Timeout. Providing the Timeout feature is enabled, a No  
Activity Timeout will disconnect resident ports or third party ports.  
Note: Option 74 in the Port Parameters Menu determines how the DTR signal will  
react when the port disconnects. The DTR signal can either be held low, held high,  
or pulsed and then held high.  
1. Resident Disconnect: Disconnects your resident port from another port. For example, if  
you are communicating via Port 3, and Port 3 is connected to Port 4, a Resident  
Disconnect would be used to disassociate the two ports. The CMS offers two different  
Resident Disconnect command formats; the Three Character Format and the One  
Character Format (for more information, please refer to Section 5.5.3.):  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (39 of 59) [11/15/2000 10:52:03 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
. Three Characters (Default): Uses the format "[Enter]LLL[Enter]", where Lis  
the selected Logoff Character. The Default Resident Disconnect Sequence is  
[Enter]+++[Enter].  
b. One Character: When the One Character Disconnect Sequence is selected, simply  
enter the selected Logoff Character once (Default = +). Note that it is not necessary  
to enter a carriage return before or after the Logoff Character.  
c. If the default Resident Disconnect Sequence is not compatible with your  
application, both the command format and Logoff Character can be redefined via  
the Port Configuration menus, as described in Section 5.5.  
2. Third Party Disconnect: (Supervisor Mode Only) The /D command is issued from your  
resident port to disconnect two third party ports. For example, if your Resident Port is  
Port 1, a Third Party Disconnect would be used to disconnect Port 3 from Port 4.  
. The /D command uses the format: /D xx XX[Enter], where xxand XX are the  
numbers of the ports that you wish to disconnect, if an Nis entered, the command  
will disconnect the Network Port.  
b. The /D (Disconnect) command can only be invoked by a port with access to  
Supervisor Level commands.  
c. The /D command can specify both connected ports, or either of the two ports. For  
example, if Port 1 is your resident port, any of the following commands can be used  
to disconnect Port 3 from Port 4:  
/D 3 4 [Enter]  
or  
/D 3 [Enter]  
or  
/D 4 [Enter]  
3. No Activity Timeout: Providing the Timeout feature is enabled at either connected port,  
the No Activity Timeout can disconnect Resident Ports, or Third Party Ports.  
. RS232 Ports: To configure the Timeout Feature for the RS232 Ports, invoke the /P  
command to display the Port Configuration Menu for the desired port as described  
in Section 5.5.3. Option 11 enables and defines the Timeout Feature.  
b. Network Port: To configure the Timeout Feature for the Network Port, invoke the  
/N command to display the Network Port Configuration Menu as described in  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (40 of 59) [11/15/2000 10:52:03 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
Section 5.5.4. Option 15 enables and defines the Timeout Feature.  
c. When the Timeout Feature is enabled, the port will automatically disconnect if no  
data is received for the defined Timeout Period.  
7.1.2. Defining Hunt Groups  
A Hunt Group creates a situation where the CMS will scan a group of ports and connect to the  
first available port in the group. Hunt Groups are created by assigning identical or similar names  
to two or more ports. Hunt Groups can be defined using Any-to-Any, Passive, Buffer, or Modem  
Mode Ports. Note that the Network Port cannot be included in Hunt Groups.  
1. Access the Command Mode. If the password prompt is displayed, enter the Supervisor  
Password.  
2. Invoke the /P command to access the Port Configuration Menu for the desired Port(s) as  
described in Section 5.5.3. For example, to configure Port 4, type /P 4 [Enter].  
3. From the Port Configuration Menu, select item 1 to define the Port Name.  
4. Repeat steps 2 and 3 above to assign identical names to the other ports in the Hunt Group.  
For example, a series of ports in a group could all be named "SERVER".  
5. To connect to the next available port in the hunt group, invoke the /C command using the  
port name to specify the desired group. For example, /C SERVER [Enter].  
6. Your port will be connected to the first available port in the group. If all ports are  
presently connected, the CMS will respond with the "BUSY" message.  
7. It is only necessary to enter enough letters of the port name to differentiate the Hunt  
Group ports from other ports. Type an asterisk (*) to represent the remaining characters in  
the port name. For example, to connect your resident port to the first available port in a  
group of ports named "SALES1", "SALES2", and "SALES3", the connect command can  
be invoked as /C S* [Enter], providing no other port names begin with the letter "S".  
Hunt Group port names must be unique. Otherwise, ports with similar names will also be  
included in the Hunt Group.  
Hunt Group Example 1:  
1. Ports 1 and 2 are Modem Mode ports, and modems are installed at both ports. Port 1 is  
named "MODEM1" and Port 2 is named "MODEM2".  
2. Your resident port is Port 4. To connect to the first available Modem, access the  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (41 of 59) [11/15/2000 10:52:03 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
Command Mode and type /C MODEM* [Enter].  
Hunt Group Example 2:  
1. Ports 3, 4, and 5 are Any-to-Any Mode ports. All three ports are named "SERVER".  
2. Your resident port is Port 1, and you want to connect Port 2 to the first available server,  
access the Command Mode and type /C 2 SERVER [Enter].  
7.2. Passive Mode  
Passive Mode Ports function the same as Any-to-Any Mode Ports, but do not allow access to  
Command Mode. A Passive Mode Port can communicate with other ports, but cannot enter  
Command Mode, and therefore cannot invoke commands to redefine port parameters, display  
status, and etc.  
Passive Mode Ports can be connected by accessing the Command Mode from a free Any-to-Any  
Mode or Modem Mode Port, and invoking the Third Party Connect or Resident Connect  
Command as described in Section 7.1.1.2. Passive Mode ports will not buffer data, except during  
baud rate conversion.  
Note:  
A Passive Mode Port is not allowed to access the Command Mode.  
In order to ensure supervisor access to important command functions, the  
Passive Mode is not available to Ports 1 and 2 (SetUp Ports).  
The Passive Mode is not available at the Network Port.  
7.3. Buffer Mode  
Ports configured as Buffer Mode ports will collect data from the connected device and store it in  
the CMS's statically allocated memory. Each CMS port features a fixed length, fixed position  
data buffer.  
The Buffer Mode allows collection of data from various devices without the requirement that all  
devices use the same communication parameters (e.g. baud rate, parity, etc.).  
Notes:  
Buffer Mode Ports cannot access the Command Mode.  
In order to ensure supervisor access to important command functions, the  
Buffer Mode is not available to Ports 1 and 2 (SetUp Ports).  
The Buffer Mode is not available at the Network Port.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (42 of 59) [11/15/2000 10:52:03 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
7.3.1. Reading Data from Buffer Mode Ports  
To retrieve data from Buffer Mode Ports, you must first determine which port buffers contain  
data. To check port buffers for stored data, access the Command Mode and type /S [Enter] to  
display the Port Status Screen.  
To retrieve data from buffer memory, go to a free Any-to-Any or Modem Mode Port, access the  
Command Mode (Supervisor Level), and issue the /C command using the following format:  
/C xx [Enter]  
Where xxis the number or name of the port buffer to be read.  
If the port's buffer is empty, the CMS will send a message which reads "Connected xx, Buffer  
Empty"; where "xx" is the port number. If the buffer contains data, the CMS will display a  
prompt that offers four options:  
Next Screen: To scroll through data one screen at a time, press the [Space] bar. Each  
time the space bar is pressed, the next full screen of data will be sent.  
Scroll All: To send all data without pausing, press [1].  
Skip/Connect: To connect to the buffer port without sending stored data, press [2].  
Erase/Connect: To connect to the buffer port and erase stored data, press [3]. Note that  
buffered data will be erased immediately and will not be sent.  
Note: All four of these options also allow pass-through communication with the  
device connected to the Buffer Mode port.  
To clear data from the buffer, use the Erase/Connect option, or go to a free Any-to-Any or  
Modem Mode Port with Supervisor Level command capability, and issue the /E (Erase Buffer)  
command using the following format:  
/E xx [Enter]  
Where xxis the number or name of the port buffer to be cleared.  
7.3.2. Port Buffers  
The Status Screen lists the amount of Buffer Memory currently used by each port. The CMS  
uses buffer memory in two different ways, depending on the user-selected port mode.  
Any-to-Any, Passive, and Modem Mode Ports: When two ports are communicating at  
dissimilar baud rates, the buffer memory prevents data overflow at the slower port.  
Buffer Mode Ports: Stores data received from connected devices. The user issues a  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (43 of 59) [11/15/2000 10:52:03 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
connect command (/C) from an Any-to-Any Mode or Modem Mode port to retrieve data.  
If the Status Screen indicates an accumulation of data, the /E (Erase Buffer) command can be  
invoked to clear the buffer.  
7.4. Modem Mode  
In addition to allowing data transfer, the Modem Mode also provides additional functions  
specifically related to modem communication. A Modem Mode Port can perform all functions  
normally available in Any-to-Any Mode. The Modem Mode is available to all CMS ports except  
the Network Port.  
When the Modem Mode is selected, the port configuration menu (command /P) will display  
three additional prompts, which allow the user to re-define the modem reset string, initialization  
string, and hang-up string.  
When the Modem Mode is selected for a port with Supervisor Level command access, the  
Supervisor Password should be defined. This will discourage unauthorized access to higher  
command functions.  
When a call is received, the unit will prompt the caller to enter a password. The CMS allows  
three attempts to enter a valid password. If the correct password is not entered in three attempts,  
or if the user does not respond to the password prompt within 30 seconds, the modem will  
disconnect.  
The password can be defined and enabled by invoking the /P command as described in  
Note:  
When a Modem Mode Port exits Command Mode, or the DCD line is lost  
while the Command Mode is active, the CMS will pulse the DTR line to the  
modem. The unit will then send the user-defined modem command strings to  
make certain the modem is properly disconnected and reinitialized.  
When an external modem is installed at a CMS port, other ports can use the  
modem for calling out. To call out, invoke the /C command to connect to the  
port, and then access the modem as you normally would.  
8. Saving and Restoring Configuration  
Parameters  
After the CMS has been properly configured, parameters can be downloaded and saved as an  
ASCII text file. Later, if the configuration is accidentally altered, the file with the saved  
parameters can be uploaded to automatically reconfigure the unit without the need to manually  
assign each parameter.  
Saved parameters can also be uploaded to other CMS units. This allows rapid set-up when  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (44 of 59) [11/15/2000 10:52:03 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
several units will be configured with the same parameters.  
The "Save Parameters" procedure can be performed from any terminal emulation program (e.g.  
ProComm, Crosstalk, Hyperterminal, etc.), that allows downloading of ASCII files.  
8.1. Sending Parameters to a File  
1. Start ProComm and access the CMS Command Mode. If the password prompt is  
displayed, enter the Supervisor Password.  
2. When the CMS command prompt appears, type /U and press [Enter]. The CMS will  
prompt you to configure your terminal emulation program to receive an ASCII download.  
Set your terminal emulation program to receive an ASCII format download, and the  
specify a name for a file that will receive the saved parameters (e.g. CMS.PAR).  
3. When the terminal emulation program is ready to receive the file, return to the CMS Save  
Parameter File menu, and press [Enter] to proceed with the download. CMS parameters  
will be saved on your hard drive in the file specified in Step 2 above.  
4. The CMS will send a series of ASCII command lines which specify the currently selected  
CMS parameters. The last line of the file should end with a "/G-00" command.  
8.2. Restoring Saved Parameters  
This section describes the procedure for using ProComm to send stored parameters to the CMS.  
1. Start your terminal emulation program and access the CMS Command Mode; if the  
password prompt is displayed, enter the Supervisor Password.  
2. Configure your terminal emulation program to upload and ASCII text file.  
3. Upload the ASCII text file with the saved CMS parameters. If necessary, key in the file  
name and directory path.  
4. Your terminal emulation program will send the ASCII text file to the CMS. When the  
terminal program is finished with the upload, make certain to terminate the Upload mode.  
Notes:  
If the CMS detects an error in the parameters file, it will respond with the  
"Invalid Parameter" message. If an error message is received, carefully check  
the contents of the parameters file, correct the problem, and then repeat the  
Upload procedure.  
When the configuration file is sent to the CMS via telnet, the unit’s IP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (45 of 59) [11/15/2000 10:52:03 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
Address, Subnet Mask, and Gateway Address cannot be altered.  
5. Type /Sand press [Enter], the CMS Status Screen will be displayed. Check the Status  
Screen to make certain the unit has been configured with the saved parameters.  
9. Upgrading CMS Firmware  
When new, improved versions of the CMS operating firmware become available, the "Upgrade  
Firmware" function can be used to update the CMS unit. Updates can be uploaded via Setup  
Ports One and Two, or via the Network Port.  
Note: All other ports will be disabled during the firmware upgrade procedure.  
1. Obtain the update file. Firmware modifications can either be mailed to the customer on a  
3.5" diskette, or downloaded from WTI via modem. Place the diskette in your diskette  
drive and/or copy the file to your hard drive.  
2. Access the CMS command mode. If the password prompt is displayed, key in the  
Supervisor Password. The Upgrade Firmware feature is only available in Supervisor  
Mode.  
3. When the CMS command prompt appears, type /UFand then press [Enter]. The CMS  
will display a screen which offers the following options:  
. Continue Upload and Keep Current Parameters: To proceed with the upgrade,  
while retaining current, user-defined parameters, type 1and press [Enter]. All  
parameter settings will be restored when the upgrade is complete.  
b. Continue Upload and Default System: To proceed with the upgrade, and reset  
parameters to default settings, type 2and press [Enter]. When the upgrade is  
complete, all parameters will be set to default values.  
Note: When the upgrade is performed via the Network Port, the CMS will not  
default the IP Address, Subnet Mask, or Gateway Address. This allows the telnet  
connection to be re-established after the upgrade procedure is complete.  
c. Abort Upload: To cancel the upgrade and return to the command prompt, type 3  
and press [Enter].  
4. Use your communication program’s (e.g. ProComm’s) upload function to transfer the  
upgrade firmware to the CMS unit. Select ASCII file format, and then specify the  
filename and directory location where the firmware upgrade file resides.  
Note: The Upload function will time-out after one minute of inactivity. If the  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (46 of 59) [11/15/2000 10:52:03 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
function times out, type 1and press [Enter] to continue, or press [Esc] to abort.  
5. If the upload is successful, the CMS will prompt the user to continue the upgrade or abort.  
. Upgrade: To continue with the upgrade, type 1and press [Enter]. CMS will erase  
the previous firmware, move new firmware from data flash to program flash  
memory, calculate and store the new checksum, and reboot. Do not attempt to  
reconnect to the CMS until the RDY indicator blinks to indicate the process is  
complete.  
b. Abort: To abort the procedure, type 2and  
press [Enter].  
6. Incomplete Upload: If the upload is interrupted, times-out, or if the file is corrupted  
during transfer, the CMS will display a screen which asks for user confirmation before  
proceeding. To proceed, type 1and press [Enter], then return to Step 4 above.  
7. Emergency Recovery: In the rare event that the CMS operating system becomes  
corrupted during installation, front panel indicators will blink five times and the unit will  
automatically switch to Emergency Recovery Mode. Please contact WTI Customer  
Service for further instructions.  
When firmware upgrades are available, WTI will provide the necessary files via modem or  
mailed diskette. At that time, an updated Users Guide or addendum will also be available.  
10. Command Reference Guide  
10.1. Command Conventions  
The commands described in this section conform to the following conventions:  
Slash Character: Most CMS commands begin with the Slash Character (/).  
Apply Command to All Ports: When the asterisk character is entered as the argument of  
the /Dcommand (Disconnect Port), or the /Ecommand (Erase Buffer) the command will  
be applied to all ports. For example, to erase all port buffers, type /E * [Enter].  
Port Name Wild Card: It is not always necessary to enter the entire port name. Port  
names can be abbreviated in command lines by entering the first character(s) of the name  
followed by an asterisk (*). For example, a port named "SERVER" can be specified as  
"S*". Note however, that this command would also be applied to any other port name that  
begins with the letter "S".  
Suppress "Sure?" Prompt: When the /D(Disconnect Port), /E(Erase Buffer), or /I  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (47 of 59) [11/15/2000 10:52:03 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
(Default and Test Unit) commands are invoked, the /Yoption can be included in the  
command line to override the "Are you Sure (y/n)?" prompt. For example, to disconnect  
Port 8 without displaying the "Sure?" prompt, type /D/Y 8 [Enter].  
Enter Key: All commands are invoked by pressing [Enter].  
Command Mode: CMS Ports will only recognize commands when the Command Mode  
has been activated. The Command Mode can be accessed from a free Any-to-Any or  
Modem Mode Port. To access the Command Mode, proceed as described in Section 5.1.  
Connected Ports: When two ports are connected, most CMS commands will not be  
recognized by either of the connected ports. The only exception is the Resident  
Disconnect Sequence (Default = [Enter]+++[Enter]).  
Configuration Menus: To exit from a configuration menu, you must press [Esc] or  
[Ctrl]+[X].  
10.2. Command Response  
When commands are sent to the CMS, the unit can respond with either verbose (English Text) or  
terse messages (numeric / abbreviated). The default message type for all ports can be set to  
either terse or verbose using Option Switch Six.  
After the unit is installed and configured, the port configuration commands (/P and /N) can  
specify an individual response format for each port. In addition to the Terse and Verbose  
response modes, the port configuration commands can also select the Quiet Mode. When the  
Quiet Mode is selected, the port will not send messages in response to commands.  
The table below summarizes the various response messages for both the Terse and Verbose  
modes.  
Terse Verbose  
0
0
1
2
3
4
5
6
OK  
RAM Test Passed  
Connected *  
Busy  
Disconnected  
Invalid Command  
Are You Sure (Y/N) ?  
Invalid Parameter  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (48 of 59) [11/15/2000 10:52:03 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
7
8
Invalid Syntax  
Invalid Access  
9
Enter Site ID:  
A
B
C
D
E
Aborted  
Enter Password:  
Invalid Password  
RAM Test Failed at *  
Inactivity Timeout, Disconnected  
Data in Buffer from Previous Connection ...  
Re-Enter Logoff Sequence to Purge Buffer.  
F
G
Asleep  
* These verbose Response Messages include additional information not provided by terse  
Response Messages.  
10.3. Command Summary  
Command Availability  
Function  
Command Syntax  
Supervisor  
User  
X
[Enter]  
Enter Command Mode  
Exit Command Mode  
Help Menu  
X
/X [Enter]  
/H [Enter]  
/J [Enter]  
/S[P] [Enter]  
/SD[Enter]  
/SN[Enter]  
X
X
X
X
X
Display Site ID  
X
Display Port Status  
Display Port Diagnostics  
Display Network Status  
X (1) (2)  
X (1)  
X
X (1)  
X (1)  
Display Port  
Parameters (Who)  
/W[P] [n] [Enter]  
X (2)  
X (3)  
/F [Enter]  
/N[Enter]  
Set System Parameters  
X
X
Set Network Port Parameters  
Set RS232 Port  
Parameters  
/P <x> [Enter]  
X
/CP[Enter]  
Copy RS232 Port Parameters  
Connect  
X
X
/C <x> [x] [Enter]  
X (4)  
Resident  
Disconnect (5)  
[Enter]+++[Enter]  
X
X
X
/D[/Y] <x> [x] [Enter]  
/D[/Y] * [Enter]  
Third Party  
Disconnect (6)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (49 of 59) [11/15/2000 10:52:03 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
/E[/Y] <x> [x] [Enter]  
/E[/Y] * [Enter]  
Erase Buffer  
X
/T[Enter]  
Reset Network Port  
Default & Test  
X
X
X
X
/I[/Y] [Enter]  
/U [Enter]  
Save Parameters  
Upgrade Firmware  
/UF[Enter]  
(1)  
Supervisor Mode displays parameters for all ports;  
User Mode only displays parameters for the ports allowed by the Port  
Password.  
(2)  
(3)  
To display Port Passwords, include the "P" Option. (Supervisor Only).  
A port with "User" command capability can only view its own  
parameters. A User Port cannot view parameters for other ports.  
(4)  
(5)  
A User Port cannot perform a Third Party Connect.  
Resident Disconnect: Disconnects your resident port from another  
port. Note that the Resident Disconnect Sequence can be redefined via  
the Port Configuration Menus.  
(6)  
Third Party Disconnect: Disconnects two or more nonresident ports.  
Must be issued from a third port with Supervisor command capability.  
10.4. Command Set  
This Section provides more detailed information on all CMS commands, sorted alphabetically by  
name.  
[Enter] Enter Command Mode  
In order to set parameters or connect ports, you must first access the command mode as  
described in Section 5.1. When the Command Mode is inactive (port asleep), the port will only  
respond when the [Enter] key is pressed without any characters preceding it. If the Supervisor  
Password (command /F) has been defined, the unit will require a password before allowing  
access to Command Mode.  
Availability: Supervisor / User  
Format: [Enter] (Press [Enter] twice if other characters have already been typed).  
Response: The Port Status Screen will be displayed, followed by the "CMS>" command  
prompt.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (50 of 59) [11/15/2000 10:52:03 AM]  
 
WTI CMS-16; Console Management Switch -- User's Guide  
[Enter]+++[Enter] Resident Disconnect Sequence  
The Resident Disconnect Sequence is issued to disconnect your resident port from another port.  
For example, if you are communicating via Port 3, and Port 3 is connected to Port 4, the  
Resident Disconnect Sequence would be used to disconnect Port 3 from Port 4. Although the  
default Resident Disconnect Sequence is [Enter]+++[Enter], the command format and Logoff  
Character can also be redefined via the Port Configuration Menus as described in Section 5.5.3.  
Note that a one character disconnect command can also be selected.  
Availability: Supervisor / User  
Format: [Enter]xxx[Enter]  
Where "x" is the selected Logoff Character, and the default character is "+".  
Response:  
Verbose: The CMS will send the "Disconnected" message, followed by the Port Status  
Screen.  
Terse: 3  
/C Connect  
Establishes a bi-directional connection between two ports. For more information and command  
line examples, please refer to Section 7.1. There are two different types of port connections:  
Resident Connect: If the /C command specifies one port name or number, your resident  
port will be connected to the specified port.  
Third Party Connect: If the /C command specifies two port names or numbers, the unit  
will connect the two ports indicated. A Third Party Connect command must be issued  
from a third port with "Supervisor" command capability. "User" ports cannot initiate a  
Third Party Connect.  
Note:  
Ports with "User" command capability can only connect to ports that share  
the same Port Password.  
Ports with "Supervisor" command capability are allowed to connect to all  
other ports.  
Availability: Supervisor / User  
Format: /C <x> [x] [Enter]  
Where xis the number or name of the port(s) to be connected.  
Response:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (51 of 59) [11/15/2000 10:52:03 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
Verbose: Connected xx, when a Resident Connection is initiated, the CMS will also display  
the currently selected Resident Disconnect Sequence for your port.  
Terse: 1  
/CP Copy RS232 Port Parameters  
Allows quick set-up when all CMS RS232 ports will be configured with the same or similar  
parameters. When the /CP command is invoked, the CMS will display a menu that is used to  
select common port parameters, which can then be copied to all CMS RS232 ports. For more  
information, please refer to Section 5.6.  
Availability: Supervisor Only  
Format: /CP[Enter]  
Response: Displays Copy Parameters Menu  
/D Third Party Disconnect  
Invoke the /D command at your resident port to disconnect two other ports. The /D command  
cannot be used to disconnect your resident port. To disconnect your resident port, issue the  
Resident Disconnect Sequence or wait for the Timeout Period to elapse (if enabled).  
Availability: Supervisor Only  
Format: /D[/Y] <x> [x] [Enter]  
Where:  
/Y  
x
(Optional) suppresses the "Sure?" prompt.  
Is the number or name of the port(s) to be disconnected. To Disconnect all ports, enter an  
asterisk. To disconnect the Network Port, enter an "N".  
Response:  
Verbose: "Are you Sure (y/n)?", if Y, unit will respond with "Disconnected".  
Terse: 5, if Y, unit will respond with 3.  
Example: To disconnect Port 2 from Port 3 without the "Sure?" prompt, access the Command  
Mode from a third port with "All" command capability and type one of the following commands:  
/D/Y 2 [Enter] or /D/Y 3 [Enter]  
/E Erase Buffer  
Erases data from the buffer for a specified port or several ports. Note that erased data cannot be  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (52 of 59) [11/15/2000 10:52:03 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
recovered.  
Availability: Supervisor Only  
Format: /E[/Y] <x> [x][Enter]  
Where:  
x
Is the number or name of the port buffer(s) to be cleared. To erase buffers for all ports,  
enter an asterisk.  
/Y  
(Optional) Suppresses the "SURE? (Y/N)" prompt.  
Response:  
Verbose: "Are You Sure (y/n)?", if Y, the unit will respond with "OK".  
Terse: 5, if Y, the unit will respond with 0.  
Example: To clear the buffer for Port 3, access the Command Mode from a port with "All"  
command capability, and type /E 3 [Enter].  
/F Set System Parameters  
Displays a menu which is used to define the Site ID message and Supervisor Password. When  
the Supervisor Password is defined, the CMS will display a password prompt before allowing  
access to command mode. For more information, refer to Section 5.4.  
Note: Make certain to record your Supervisor Password for future reference. If the  
Supervisor Password is lost or forgotten, you will not be able to access Supervisor  
Level commands.  
Availability: Supervisor Only  
Format: /F[Enter]  
Response: Displays System Parameters Menu  
/H Help  
Displays a Help Screen, which lists all CMS commands along with a brief description of each  
command.  
Availability: Supervisor / User  
Format: /H [Enter]  
Response: Displays Help Screen. Note that the User Level Help Screen does not include  
Supervisor Level Commands.  
/I Default and Test  
Tests internal memory and initializes the unit with the default parameters specified by the Option  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (53 of 59) [11/15/2000 10:52:03 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
Switches.  
Caution: When /Iis invoked, the CMS will revert to the parameters  
specified by the Option Switches. Command selected parameters will be lost.  
Availability: Supervisor Only  
Format: /I[/Y] [Enter]  
Where /Yis a command option used to suppress the "Sure?" prompt.  
Response:  
Verbose: "Are You Sure (y/n)?", if Y, memory test and initialization begins.  
Terse: 5, if Y, memory test and initialization begins.  
/J Display Site ID  
Displays the user-defined Site I.D. message.  
Availability: Supervisor / User  
Format: /J [Enter]  
Response: Displays Site I.D. Message  
/N Set Network Port Parameters  
Displays a menu which is used to define communication parameters for the Network Port. Also  
allows access to the IP Security function, which is used to restrict network access by  
unauthorized IP addresses. For more information on selecting network parameters, please refer  
Availability: Supervisor Only  
Format: /N[Enter]  
Response: Displays Network Parameters Menu  
/P Set RS232 Port Parameters  
Displays a menu which allows the user to select options and parameters for the selected port.  
Section 5.5.3 describes the procedure for defining port parameters.  
Availability: Supervisor Only  
Format: /P [x] [Enter]  
Where xis the number or name of the port to be configured. If the port number or name is  
not specified, the CMS will display the configuration menu for your resident port.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (54 of 59) [11/15/2000 10:52:03 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
Response: The Port Parameters Menu is displayed.  
/S Display Port Status  
Displays the Port Status Screen, which lists current conditions and parameters for all ports.  
Normally, the Port Status Screen will not display Port Passwords; the Password column will read  
either "defined" or "undefined", depending upon whether or not the password for each port has  
been specified. When the Supervisor Mode is active, the /SP command offers the option to either  
display or suppress Port Passwords. For more information on the Port Status Screen, please refer  
Availability: Supervisor / User  
Format: /S[P] [Enter]  
When the "P" option is included (e.g. /SP), the Port Status Screen will lists the password for  
each port, if defined. (Supervisor Mode Only).  
Response: Displays Port Status Screen  
/SD Display Port Diagnostics  
Provides more detailed information regarding the operational status of each port. Note that in  
User Mode, this screen will only display parameters for the ports that are allowed by the Port  
Password that was entered at log in. For More information on the Port Diagnostics Screen,  
please refer to Section 6.2.  
Availability: Supervisor / User  
Format: /SD[Enter]  
Response: Displays Port Diagnostics Screen  
/SN Display Network Status  
Displays the Network Status Screen, which lists current conditions and parameters for the  
Network Port. For more information on the Network Status Screen, please refer to Section 6.3.  
Availability: Supervisor Only  
Format: /SN[Enter]  
Response: Displays Network Status Screen  
/T Reset Network Port  
Resets the NIC card, and breaks the network connection to the unit. Note that when this  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (55 of 59) [11/15/2000 10:52:03 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
command is invoked, the network connection will be reset without warning, and must then be  
re-established in order to communicate with the unit via Network.  
Availability: Supervisor Only  
Format: /T[Enter]  
Response: None (NIC Card is reset, Network Connection  
is broken)  
/U Save Parameters  
Sends CMS configuration parameters to an ASCII text file as described in Section 8.  
Availability: Supervisor Only  
Format: /U [Enter]  
Response: The CMS will send a series of command lines.  
/UF Upgrade Firmware  
When new versions of the CMS operating firmware become available, this command is used to  
update the existing firmware as described in Section 9. Note that this command will only  
function at the Network Port and at Setup Ports One and Two.  
Availability: Supervisor Only  
Format: /UF[Enter]  
Response: The CMS will display a menu which offers the options to retain existing CMS  
parameters, default parameters, or abort the upgrade procedure.  
/W Display Port Parameters (Who)  
Displays configuration of an individual port, but does not allow the user to change parameters.  
Ports with User Level command capability cannot display parameters for other ports. Normally,  
the Port Parameters screen will not include the Port Password. Note however, that when the  
Supervisor Mode is active, the /WP option can be used to display the password for the target  
port. For more information, please refer to Section 6.4.  
Availability: Supervisor / User  
Format: /W[P] [x] [Enter]  
Where:  
When the "P" option is included (e.g. /WP 5), the Port Parameters screen will list the  
password for each port, if defined. (Supervisor Mode Only).  
P
Is the port number or name. To display parameters for the Network Port, enter an "N". If the  
"x" argument is omitted, parameters for your resident port will be displayed.  
x
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (56 of 59) [11/15/2000 10:52:03 AM]  
WTI CMS-16; Console Management Switch -- User's Guide  
Response: Displays port parameters.  
Example: To display parameters for a port named "SERVER", access the Command Mode from  
a port with Supervisor Level command capability, and type /W SERVER [Enter].  
/X Exit Command Mode  
Exits Command Mode, When issued at the Net Port, also ends the telnet session. Note that  
exiting from Command Mode will not terminate port connections.  
Any-to-Any Mode: Exits Command Mode.  
Modem Mode: Disconnects and resets modem, hang-up message is sent, hardware line to  
modem drops for 500 ms, and reset message is sent.  
Availability: Supervisor / User  
Format: /X [Enter]  
Response: Disconnected  
Appendix A. RS232 Port Interface  
Figure A.1: RS232 Port Interface  
DCD and DTR hardware lines function as follows:  
1. When connected:  
. If either port is set for Modem Mode, the DTR output at either port reflects the  
DCD input at the other end.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (57 of 59) [11/15/2000 10:52:03 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
b. If neither port is set for Modem Mode, DTR output is held high (active).  
2. When not connected:  
. If the port is set for Modem Mode, upon disconnect DTR output is pulsed for 0.5  
seconds and then held high.  
b. If the port is not set for Modem Mode, DTR output is controlled by the DTR Output  
option (Parameters Menu, Option 74). Upon disconnect, Option 74 allows DTR  
output to be held low, held high, or pulsed for 0.5 seconds and then held high.  
Appendix B. Specifications  
RS232 Port Interface: 16 RS232 serial inputs use DB9 connectors configured as DTE  
ports.  
Network Interface: 10Base-T Ethernet, RJ45  
Coding: Asynchronous, 7/8 bits ASCII.  
Parity: Even, Odd, None  
Stop Bits: 1 or 2.  
Data Rate: 300 to 115.2K bps (all standard rates).  
Flow Control: XON/XOFF, RTS/CTS, Both, or None.  
Timeout: No activity timeout disconnects port. 1, 5, 10, 15, 30 seconds, 1, 5, 15, 30, 90  
minutes.  
Memory: Stores Parameters and captured data. Non-volatile 512K SRAM buffer  
memory. Statically allocated.  
Break: Accept Break or Refuse Break  
Option Switch: 8 position DIP switch, selects default settings for baud rate, flow control,  
response message format, and command echo.  
LEDs: Power On, Ready, Net, Data Activity for Ports 1 through 16.  
Temperature: 0°C to 45°C (operating)  
Power:  
AC Version: IEC-32 Inlet, 115/230 VAC, 50/60 Hz, 5 watts  
DC Version: Terminal Strip (#6-32), -48 VDC, 0.2 Amp Max.  
Size: 2.8" x 17" x 6.8" (H x W x D)  
Weight: 8 lbs. shipping weight  
Humidity: 10 to 90% RH, Non-Condensing  
Venting: Side vents are used to dissipate heat generated within the unit. When mounting  
the unit in an equipment rack, make certain to allow adequate clearance for venting.  
Appendix C. Customer Service  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (58 of 59) [11/15/2000 10:52:03 AM]  
   
WTI CMS-16; Console Management Switch -- User's Guide  
Customer Service hours are from 8:00 AM to 5:00 PM, PST, Monday through Friday. When  
calling, please be prepared to give the name and make of the unit, its serial number and a  
description of its symptoms. If the unit should need to be returned for factory repair it must be  
accompanied by a Return Authorization number from Customer Service.  
WTI Customer Service  
5 Sterling  
Irvine, California 92618  
949-586-9950  
Toll Free: 1-800-854-7226  
Trademark and Copyright Information  
WTI and Western Telematic are trademarks of Western Telematic Inc.. All other product names  
mentioned in this publication are trademarks or registered trademarks of their respective  
companies.  
Information and descriptions contained herein are the property of Western Telematic Inc. Such  
information and descriptions may not be copied, disseminated, or distributed without the express  
written consent of Western Telematic Inc.  
© Copyright Western Telematic Inc. 2000.  
Printed in the United States of America.  
February, 2000  
Part Number: 13027, Revision: B  
Trademarks Used in this Manual  
ProComm and ProComm Plus are registered trademarks of Datastorm Technologies, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
file:///C|/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (59 of 59) [11/15/2000 10:52:03 AM]  

Whirlpool Clothes Dryer 8280525 User Manual
Whirlpool Dishwasher 119 User Manual
Whirlpool Dishwasher DP8350XV User Manual
Whirlpool Dishwasher WDF518SAAM User Manual
Whirlpool Freezer EV209NBTQ00 User Manual
Xantrex Technology Marine Battery 975 0205 01 01 User Manual
Xerox Washer Dryer AQM8F 49 I User Manual
Yamaha Computer Hardware DRCX User Manual
Zanussi Washer FLS 1084 User Manual
Zenoah Brush Cutter BKZ4500DL User Manual