Weil McLain Burner 800060000 Brn PO Rie BF5 User Manual

Installation & Operating Manual  
Single stage operation oil burners  
RETROFIT APPLICATIONS ONLY  
If this burner is being installed in a packaged unit (ie. burner comes with a boiler or furnace), follow  
the installation and set-up instructions supplied with the heating unit, as settings may differ from  
those shown in this manual.  
- The following pages contain information, descriptions and diagrams for the proper installation  
and wiring of the burner. Please read carefully before attempting final installation.  
- This manual is to remain with the final installation designation. It is the installer’s responsibility to en-  
sure that the burner installation and operation instructions mentioned in this manual are followed and  
operated within local code authority limits.  
This burner is not equipped for 2 line operation.  
For 2 line operation order: part # C7001025 for BF3, C7001026 for BF5.  
RIELLO 40 BF  
CODE  
MODEL  
TYPE  
C8512352  
C8512353  
C8512354  
800060000-Brn-PO Rie BF5  
800061000-Brn-PO Rie BF5  
800062000-Brn-PO Rie BF5  
1.00GPH Vnt-D  
1.20GPH Vnt-D  
1.40GPH Vnt-D  
C6501073(0)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
TABLE OF CONTENTS  
PACKAGE CONTENTS LIST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
SERIAL NUMBER IDENTIFICATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
TECHNICAL DATA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2  
Burner and mounting flange dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Burner components identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
MOUNTING THE BURNER TO BOILER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3  
ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
APPLICATION FIELD WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
INSERTION / REMOVAL OF DRAWER ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5  
ELECTRODE SETTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5  
NOZZLE PLACEMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
TURBULATOR SETTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5  
OIL LINE CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
Single line (Gravity feed system) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
NPTF - NPT pipe adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Two line (Lift system) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
PUMP PURGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
Single line (Gravity feed system) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
Two line (Lift system) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
SETTING THE AIR ADJUSTMENT PLATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
COMBUSTION CHAMBER PRESSURE CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9  
BURNER SET UP CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
BURNER START-UP CYCLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
TROUBLE SHOOTING CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
A TYPICAL LAYOUT FOR BF BURNER INTAKE AIR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
EXPLODED SPARE PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
SPARE PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
BURNER START-UP LIST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  
3398  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
PACKAGE CONTENTS LIST  
Your Riello 40 BF burner should include the following parts. Please check to make sure all parts are present before be-  
ginning the installation.  
Quantity Description  
Code  
1
1
1
1
Burner with combustion head mounted  
Mounting gasket  
Parts bag  
C6880016  
C7001060 - C7001038  
C6501073  
Installation manual  
Parts bag C7001060 - C7001038  
Quantity Description  
1
1
2
3
NPT - NPTF pipe adapter  
3/8” straight connector  
Anti-shorts bushings  
Wire nuts  
SERIAL NUMBER IDENTIFICATION  
The Riello 15 character serial number, example,  
06 A 8511111 00025, is identified as follows:  
(06)  
(A)  
(8511111)  
(00025)  
06  
= Last two digits of the year of manu-  
facture;  
A
= BI-week of manufacture;  
Year of  
manufacture  
BI-week of  
manufacture  
Burner  
product code  
Increment  
8511111 = Burner product code;  
00025 = Increment of 1 for each burner pro-  
duced – specific to product code –  
reset to zero each January 1st.  
3398  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
TECHNICAL DATA  
B
SPECIFICATIONS  
Fuel  
No. 2 Fuel Oil  
BF3 Firing rate - Effective Output  
BF5 Firing rate - Effective Output  
Voltage (single phase)  
BF3 Absorbed electrical power  
BF5 Absorbed electrical power  
Motor (rated)  
0.50 to 0.95 US GPH - 70,000 to 133,000 BTU/h  
0.75 to 1.65 US GPH - 105,000 to 231,000 BTU/h  
120V 60Hz (+ 10% - 15%)  
192 Watts  
204 Watts  
3250 rpm Run Current 2.2 AMP  
12.5 Microfarads 260V  
100 to 200 PSI  
Capacitor  
E
F
Pump pressure  
Primary control  
RIELLO 530 SE/C  
Ignition transformer  
8kV 16mA  
BURNER AND MOUNTING FLANGE DIMENSIONS  
Model  
A
B
C
D
E
F
Inches 9 13/16  
11 1/4  
286  
11 1/2  
292  
7 1/2  
193  
7 1/2  
193  
3 1/2  
89  
3 1/2  
89  
4 5/8  
117  
6 5/16  
160  
8 21/32  
220  
6 13/16  
173  
BF3  
BF5  
mm  
Inches 9 13/16  
mm 249  
249  
D7515  
BURNER COMPONENTS IDENTIFICATION  
1
7
6
17  
2
3
9
5
/
”-141mm  
16  
9
7 / ” - 192 mm  
16  
1
8 / ” - 216 mm  
2
5
D7516  
4
BURNER COMPONENTS  
D8174  
1
2
3
4
5
6
7
8
9
Lockout indicator lamp and reset button  
8
9
10  
Primary control  
Primary control sub-base  
Pump pressure regulator  
Post purge timer  
Air adjustment  
Capacitor  
Combustion head  
Mounting gasket  
11  
12  
3
0
10 Universal mounting flange  
11 Turbolator adjustment screw  
12 Coil  
13 Bleeder and pressure gauge port  
14 Return fuel line port  
15 Inlet fuel line port  
16 Pump  
15  
14  
16  
13  
17 Air pressure switch  
3398  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
MOUNTING THE BURNER TO THE BOILER  
- Position the MOUNTING GASKET (2) be-  
tween the flat surface of the UNIVERSAL  
MOUNTING FLANGE (1) installed on the  
burner and the appliance.  
- Line up the holes in the UNIVERSAL  
MOUNTING FLANGE with the STUDS  
(3) on the appliance mounting plate and  
securely bolt the UNIVERSAL MOUNT-  
ING FLANGE to the plate.  
To remove the burner from the boiler, re-  
verse the procedure.  
E9328  
ELECTRICAL CONNECTIONS  
It is advisable to leave the control box off the sub-base while com-  
pleting the electrical connection to the burner.  
1) Wire access hole (Use BX electrical connector)  
2) Earth ground conductor terminal (Green wire)  
3) Hot conductor terminal (Black wire)  
4) Neutral conductor terminal (White wire)  
WARNING:  
The hot (black) wire must be connected to the L terminal and the  
neutral (white) wire must be connected to the N terminal or the  
primary safety control will be damaged.  
Do not connect wither wire to the terminal marked  
.
D7954  
Using the appropriate diagram below, make electrical connec-  
tions to burner.  
All wiring must be done in accordance with existing electrical codes, both national and local.  
When all electrical connections have been made, the control box may be put back in place on the sub-base.  
WARNING: DO NOT activate burner until proper oil line connections have been made, or failure of the  
pump shaft seal may occur.  
3398  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
APPLICATION FIELD WIRING  
REMOTE SENSING OF SAFETY LOCKOUT  
The SAFETY SWITCH in the 530SE CONTROL BOX is equipped with a contact allowing remote sensing of burner  
lockout. The electrical connection is made at terminal 4 ( ) on the SUB-BASE.  
Should lockout occur the 530SE CONTROL BOX will supply a power source of 120Vac to the connection terminal.  
The maximum allowable current draw on this terminal (4) is 1 Amp.  
WARNING:  
If a neutral or ground lead is attached to this terminal, the CONTROL BOX on the burner will be damaged  
should lockout occur.  
Earth  
Ground  
L2  
L1  
Fuse 15 A  
SAFETY  
Switches  
LIMIT  
Switches  
FIELD  
WIRING  
W
G
R
B
FACTORY WIRED  
SUB BASE  
BLACK  
GREEN  
BROWN  
BLACK  
N
4
L
1
8
AIRPR SSURE  
SWITCH  
Oil Valve  
Ground  
Control Box  
530 SE/C  
BLUE  
11  
10  
BLUE  
BLUE  
BLUE  
BLUE  
3
2
12  
9
7
6
YELLOW  
AL 1009-1  
Burner Fan-Off  
Timer  
GREY  
RED  
Capacitor  
D8173  
BLACK  
M
Motor  
3398  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
INSTALLATION/REMOVAL OF DRAWER ASSEMBLY  
Removal:  
A) Remove the air pressure switch support  
(6) from the front shield by the two retain-  
ing screws (7)  
B) Loosen off oil delivery tube nut from  
pump.  
C) Loosen SCREW (3), and then unplug  
CONTROL BOX (1) by carefully pulling it  
back and then up.  
D) Remove the AIR TUBE COVER PLATE  
(5) by loosening the retaining SCREW  
(4) (Two SCREWS – Model BF5).  
E) Loosen SCREW (2), and then slide the  
complete drawer assembly out of the  
combustion head as shown.  
F) To insert drawer assembly, reverse the  
procedure in items A to E above.  
E9327  
ELECTRODE SETTING  
5/32” or 4 mm  
IMPORTANT:  
These dimensions must be observed and verified.  
D6003  
5/32” to 13/64” or 4 to 5 mm  
NOZZLE PLACEMENT  
- Remove the NOZZLE ADAPTER (2) from the DRAWER  
ASSEMBLY by loosening the SCREW (1).  
- Insert the proper NOZZLE into the NOZZLE ADAPTER and  
tighten securely (Do not over tighten).  
- Replace adapter, with nozzle installed, into drawer assem-  
bly and secure with screw (1).  
IMPORTANT:  
S7459  
The nozzle and the pump pressure must be in accordance  
with the burner setup chart at page 9.  
TURBULATOR SETTING  
A) Loosen NUT (1), and then turn SCREW (2) until the INDEX  
MARKER (3) is aligned with the correct index number as  
per the burner setup chart at page 9.  
3
2
1
B) Retighten the RETAINING NUT (1).  
MODEL BF3: Zero and three are scale indicators only.  
From left to right the first line is 3 and the last line 0.  
MODEL BF5: Same as above, except scale indicators are 0  
and 4.  
D7520  
3398  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
OIL LINE CONNECTIONS  
This burner is shipped with the oil pump set to operate on a single line system.  
To operate on a two-line system the by-pass plug must be installed.  
WARNING  
Do not operate a single line system with the by-pass plug installed.  
Operating a single line system with the by-pass plug installed will result in damage to the pump shaft seal.  
NOTE:  
1
Pump pressure must be set at  
time of burner start-up.  
A pressure gauge is attached  
to the PRESSURE PORT (8)  
for pressure readings.  
8
All pump port threads are Brit-  
ish Parallel Thread design.  
Direct connection of NPT  
threads to the pump will dam-  
age the pump body.  
Riello manometers and vacuum  
gauges do not require any  
adapters, and can be safely  
connected to the pump ports.  
An NPT (metric) adapter must  
be used when connecting other  
gauge models.  
D7521  
7
2
4
SINGLE LINE (GRAVITY FEED SYSTEM)  
The burner is shipped configured for use in single line applications.  
No changes to the oil pump are required for use in single line applications.  
NOTE:  
If the pump cover (1) is removed for any reason, be sure the O-ring (2), is properly seated in the pump cover (1) before  
re-attaching the pump cover to the pump housing.  
Install the required fitting NPTF to NPT adapter into the pump's SUCTION LINE CONNECTION FITTING on left side  
of burner on top.  
Attach the required tubing to this fitting. Be sure that the plug in the RETURN LINE CONNECTION FITTING is  
tightened securely.  
SINGLE LINE SYSTEM-PIPE LENGTHS  
H
3/8” OD  
1/2” OD  
FT  
1.5  
3.0  
5.0  
6.5  
M
FT  
M
FT  
M
20  
0.5  
1.0  
1.5  
2.0  
33  
65  
10  
20  
40  
60  
65  
130  
260  
325  
40  
ATTENTION:  
do not exceed  
pipe lengths  
130  
195  
80  
100  
indicated in chart!  
D7523  
3398  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
NPTF - NPT pipe adapter  
The BF burner you have purchased is shipped with an NPTF  
to NPT fitting. This fitting is the connection point for the oil line  
from the oil tank or the in-line oil filter. In some locations, fit-  
tings with the NPTF male thread are difficult to obtain.  
In these areas, a more common NPT thread male fitting or  
pipe may be used. To accommodate this NPT thread, the BF  
NPT-NPTF adapter is supplied. This brass adapter is  
installed as shown below.  
Dryseal NPTF to NPT adapter  
Bulkhead fitting  
Installation of NPT-NPTF pipe adapter  
1 The brass adapter may be threaded directly into the steel  
female fitting already installed in the BF burner chassis.  
No pipe sealant is required since this thread is self-sealing.  
2 Ensure that the brass adapter is tightly fitting into the steel  
adapter.  
BF burner chassis wall  
Retaining nut  
3 Fit the pipe or fitting used to connect the oil supply system  
into the brass adapter.  
D7522  
Use pipe sealant to ensure a leak-free joint.  
TWO LINE (LIFT SYSTEM) (Accessory package required)  
If a two-line system is required, install the By-pass plug. The by-pass plug is installed in the return port of the pump.  
A 2.5-mm hexagonal key is to be used to install the plug.  
DO NOT use an inch size hexagonal key; damage to the by-pass plug may result.  
A) Suction and return lines should be sized in accordance with local codes. The suction line should extend down  
near the bottom of the oil tank. The return line should terminate near the top of the oil tank.  
B) Suction and return lines should be sized in accordance with local codes and both should extend to the same depth  
inside the fuel tank. Be sure there are no air leaks or blockages in the piping system. Any obstructions in the return  
line will cause failure of the pump shaft seal. Do not exceed the pipe lengths indicated in the table.  
Install the required fittings (NPT THREAD) in the SUCTION LINE and RETURN LINE CONNECTION FITTINGS.  
Attach the required tubing to these fittings.  
2 LINE (LIFT) SYSTEM-PIPE LENGTHS  
A
H
3/8” OD  
1/2” OD  
FT  
0.0  
1.5  
3.0  
5.0  
6.5  
9.5  
11  
M
FT  
M
35  
30  
25  
20  
15  
8
FT  
M
100  
100  
100  
90  
70  
30  
20  
0.0  
0.5  
1.0  
1.5  
2.0  
3.0  
3.5  
115  
100  
80  
65  
50  
330  
330  
330  
295  
230  
100  
65  
ATTENTION:  
do not exceed  
pipe lengths  
indicated in chart!  
25  
20  
D7524  
6
To install the by-pass plug:  
1) Remove the return plug (7).  
2) Install the by-pass plug (4) using the 2.5 mm hexagonal key.  
3) Connect the return line connection pipe to the return port (7)  
of the pump and tighten securely.  
B
WARNING:  
- Pipe dope or Teflon tapes are NOT to be used on any direct oil connection to the fuel pump.  
- The height ‘P’ in Pipe Length Charts should not exceed 13 feet (4 m).  
- The vacuum should not exceed 11.44 inches of mercury.  
IMPORTANT: An external, appropriately listed and certified oil filter must be placed in the fuel line between  
the fuel tank and the burner pump.  
3398  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
PUMP PURGE  
NOTE: To protect the pump gears, it is advisable to lubricate the  
pump prior to purging a lift system.  
B
C
Apply oil through the VACUUM PORT (C).  
A) SINGLE LINE (GRAVITY FEED SYSTEM)  
I. Loosen the bleeder valve (A) until oil flows out.  
Tighten the bleeder valve securely and startburner.  
II. When bleeding the pump by pressure:  
A
1) Loosen the bleeder valve (A).  
2) Disconnect nozzle oil supply line at the pump nozzleport (B).  
3) Attach a flexible plastic tube to the pump nozzle, port directing  
the oil flow into a bucket.  
4) Loosen the screw(s) securing the air tube cover, allowing it to  
be removed freely.  
5) Holding the air tube cover in its proper location start the burner.  
6) When the solenoid valve is engaged approximately 10 seconds  
after starting, remove the air tube cover and shine a light  
source on the photocell, allowing it to see false light.  
D7527  
7) Run the burner until the fuel pump has been purged of air, then tighten the bleeder valve and immediately  
shut down the burner.  
8) Reinstall the air tube cover and nozzle line.  
9) The burner can now be started normally.  
WARNING: Omitting steps 2 and 3 will result in a collection of unburned oil in the combustion chamber creating a  
hazardous situation upon burner startup.  
B) TWO LINE (LIFT SYSTEM)  
Turn off the main power source to the burner and remove the air tube cover. Shines a light source on the photocell  
(now visible where the air tube cover was removed), return power to the burner and activate the burner. With the  
light source in place, the burner will operate in prepurge only. Once the burner is purged, turn off the power source  
and replace the air tube cover. Return power to the burner. The burner is now ready to operate.  
ATTENTION: It is important that the fuel line be completely sealed and free from air leaks or any internal blockages.  
WARNING! WHEN THE BYPASS PLUG IS INSTALLED, A TWO-PIPE SYSTEM MUST BE USED OR FAILURE OF  
THE PUMP SHAFT WILL OCCUR.  
SETTING THE AIR ADJUSTMENT PLATE  
2
A) The initial air damper setting is made by turning screw (2) until  
the top edge of the air damper (3) is aligned with the number ac-  
cording to the burner setup chart.  
B) Further adjustments can be made with the burner cover in place  
1
by removing plastic plug on the top right hand side of the cover.  
Turn the screw counter clockwise (+ indicator) to increase com-  
bustion air, turn the screw clockwise (- indicator) to decrease  
combustion air.  
C) The final position of the air damper will vary on each installation.  
Use instruments to establish the proper settings for maximum  
CO2 and a smoke reading of zero.  
NOTE:  
Variations in flue gas, smoke, CO2, and temperature readings may  
be experienced when the burner cover is put in place.  
Therefore, the burner cover must be in place when making the final  
3
combustion instrument readings, to ensure proper test results.  
D5141  
3398  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
COMBUSTION CHAMBER PRESSURE CHART  
BURNER OUTPUT VS CHAMBER PRESSURE CHART  
0.5  
0.4  
0.3  
0.2  
0.1  
(GPH) BURNER OUTPUT  
D7525  
0.0  
0.50  
0.75  
1.00  
1.25  
1.50  
1.75  
RIELLO BURNER SET UP SHEET  
Weil McLain Part No.  
Riello Part No.  
8000-60000  
8000-61000 8000-62000  
C8512352  
C8512353  
BF5 Factory  
preset *1  
UO4  
C8512354  
BF5 Factory  
preset *1  
UO5  
Riello 40  
BF5 Factory  
preset *1  
UO3  
BF5  
Burner Model  
Series  
Boiler  
UO3  
0,8  
Input  
GPH  
1,0  
1,2  
1,4  
Nozzle  
Delavan  
.65 X 70°B  
.85 X 60°B  
1.00 X 70°B  
1.10 X 70°B  
Pump Pressure  
PSI  
150  
145  
145  
160  
Turbolator Setting  
Air Gate Setting  
0
3.5  
8
1
4.25  
8
3
5.0  
8
4
5.5  
8
Air tube length  
inches  
Ait tube insertion  
inches  
4 1/4"  
4 1/4"  
4 1/4"  
4 1/4"  
*1 Nozzle pre-installed at factory.  
3398  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
BURNER START-UP CYCLE  
Normal  
Thermostat  
Lock-out, due to light-failure  
Motor  
Ignition transformer  
Valve  
Flame  
Lock-out lamp  
D7526  
~ 12sec.  
2min.  
~ 12sec.  
~ 5sec.  
3398  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
TROUBLE SHOOTING CHART  
Thermostat is calling for heat  
Burner is not running  
Reset Control Box  
Burner Starts  
Burner Does Not Start  
Test for 120Vac Supply at sub-base between L(P) & N  
or terminals #3 & 5  
120 Vac  
No Voltage  
• Check system fuse, ensure service switch is ON.  
• Verify all control limits are closed.  
• If using switching relay - verify 24Vac at T-T.  
Turn off power supply - Remove control box and jumper  
terminals #5 & 6. Restore power.  
Motor Runs  
Motor Does Not Run  
• Verify electrical connections.  
• Check for seized pump, motor, or fan against housing.  
• Defective motor capacitor.  
• Thermal overload (Hot motor).  
• Verify reduced voltage (42-52 Vac) between terminals #3 & 7.  
• Ensure good contact between control box spades  
and sub-base terminals.  
• Defective control box / Replace.  
Burner stays in Pre-purge  
• Faulty CAD cell or seeing light before trial for ignition.  
• Coil wire on terminals #1 & 2 or #1 & 8 reversed.  
• Open coil circuit, terminals #2 & 8.  
• Open coil circuit, terminal #1 (530 SE only).  
• Open coil circuit, terminal #1 (483 SE only) will cause burner  
to cycle normally, but burner will lockout.  
• Defective 42-52 Vac supply - Terminals #3 & 7.  
• Defective control box / Replace.  
Burner Continues to Purge and Lightoff with  
Immediate Flame Dropout. (530 SE Only)  
• Metal yoke for coil missing.  
• Coil wire #2 & 8 reversed.  
• Low resistance of coil holding circuit, terminals #1 & 2,  
(1350 ohms 10%).  
Burner Locks Out After Trial For Ignition  
• Low resistance or no contact on starting circuit of coil,  
terminals #2 & 8. (1.3 ohm 10%)  
• No oil supply - tank empty, valve closed, dirty filter,  
damaged supply lines.  
• Defective or dirty oil valve stem, nozzle or pump strainer.  
• Broken pump drive key, defective pump, no oil pressure.  
• Ignition electrodes shorted, cracked porcelain.  
• Burner motor not up to speed.  
• Excessive draft over fire.  
• Defective control box / Replace.  
Burner Fires-Cycles On & Off  
In Quick Succession - (483SE Only)  
• Metal yoke for coil missing.  
• Low resistance or short in holding circuit of coil,  
terminal #1 & 2.  
• Coil wires on terminals #2 & 8 reversed.  
3398  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
A TYPICAL LAYOUT FOR BF BURNER INTAKE AIR  
A) Use an approved air intake kit.  
B) Always keep intake air run to the minimum.  
C) Maximum intake air run of 4 (inch) diameter, flexible or rigid type of venting = 100í  
D) Reduce intake air length by 10’ for every 90° elbow used. 5’ for every 45° elbow used.  
E) It is suggested that air intake venting be insulated with R7 (min) foil lined insulation a minimum of 10’ from air intake  
source. (Prevent condensation or corrosion of intake air venting)  
F) Used approved type of intake air vacuum breaker and to be installed in the same room and the burner, for the event  
of intake air source being blocked, this device should be tested to prove that in the event of intake air source is blocked  
that the vacuum breaker balancer is set correctly and can provide sufficient air for combustion for the burner. If the  
room that the burner is installed into cannot provide enough air or air quality is a concern, an additional air inlet source  
will have to be providing to this room.  
THIS INTAKE AIR LAYOUT FOR CHIMNEY APPLICATIONS ONLY  
3398  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXPLODED SPARE PARTS LIST  
3398  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPARE PARTS LIST  
No.  
CODE  
DESCRIPTION  
No.  
CODE  
DESCRIPTION  
39 3002361  
40 3008891  
41 3006977  
42 3006966  
43 3006965  
44 3002363  
45  
REGULATOR ASSEMBLY  
ELECTRODE ASSEMBLY  
TURBULATOR DISC  
1
2
3
4
5
6
7
8
9
C8111015  
BURNER BACK COVER  
CRUSHABLE METAL WASHER 3/8” ID  
BLEEDER  
O-RING - PUMP PRESSURE REGULATOR  
REGULATOR SCREW  
O-RING - PUMP COVER  
PUMP SCREEN  
3007077  
3007568  
3007028  
3007202  
3007162  
3005719  
3006925  
3007203  
ELECTRODE SUPPORT  
NOZZLE ADAPTER  
NOZZLE OIL TUBE  
AL 1009 POST PURGE DEVICE KIT  
AIR PRESSURE SWITCH UO3 (0,6" wc)  
AIR PRESSURE SWITCH UO4-UO5 (0,7" wc)  
C7010002  
C7001084  
C5332055  
C5332056  
46  
VALVE STEM  
PLATE - VALVE STEM RETAINER  
O-RING - VALVE STEM UPPER  
O-RING - VALVE STEM LOWER  
NOZZLE OUTLET FITTING  
CRUSHABLE METAL WASHER 5/8” ID  
COIL U-BRACKET AND RETAINER NUT  
COIL  
PUMP  
PUMP DRIVE KEY  
MOTOR  
10 3007029  
11 3007156  
12 3007581  
13 3007087  
14 3006553  
15 3002279  
16 3007802  
17 3000443  
18 3005843  
46  
47  
48  
C5320037  
C7001330  
WIRING HARNESS  
BF5 SBT WELDED 4.25" COMPLETE  
19 3007316  
20 3002278  
21 3001157  
22 3002280  
AIR TUBE COVER PLATE  
PRIMARY CONTROL SUB BASE  
PRIMARY CONTROL 530SE/C  
PHOTOCELL  
C7001029  
23 3008079  
24 3000932  
25 3020248  
BURNER FRONT PLATE  
MOVEABLE FLANGE  
MOUNTING GASKET  
26 3008024  
27 3005869  
28 3007627  
29 3007630  
OIL SUPPLY TUBE & ADAPTER FITTING  
ELECTRODE PORCELAIN  
PUMP-COVER OPENING-BURNER RESET  
GASKET - BURNER COVER  
30 3000681  
31 3008021  
32  
MANUAL AIR DAMPER REGULATOR  
AIR DAMPER  
BF5 SBT WELDED 4.25" TUBE ONLY  
C7001337  
33 3005844  
34 3005708  
35 3007706  
36 3008825  
37  
CAPACITOR 12.5 µF  
FAN  
PLUG  
DRIP  
38  
3398  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GB  
35 Pond Park Rd.  
Hingham, MA 02043  
Phone: 781-749-8292  
Toll Free: 800-992-7637  
Fax: 781-740-2069  
2165 Meadowpine Blvd.  
Mississauga,On L5H 3R2  
Phone: 905-542-0303  
Toll Free: 800-387-3898  
Fax: 905-542-1525  
BURNER START- UP FORM *  
Burner S/N. or Model:  
Installer name:  
Company:  
Appliance:  
Installation date:  
Fax:  
Address:  
Phone:  
Owner Name:  
Address:  
Phone:  
E-mail:  
Burner Start-up Info (OIL)  
Nozzle info:  
Air setting:  
Pump pressure:  
Turbolator setting:  
Draft breech:  
Draft overfire:  
CO2:  
CO:  
O2:  
Two lines:  
Smoke density:  
(Bacharach)  
Single line:  
This form was designed and provided in the installation manual for reference and also for providing tech-  
*
nical information which can be faxed or mailed to our technical hot-line coordinator when technical assis-  
tance is required. Please complete this form, fax it or mail it at the address/fax above, or send an e-mail  
with the information listed below to: [email protected]  
3398  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
35 Pond Park Road  
Hingham, MA 02043  
Phone 781-749-8292  
Toll Free 800-992-7637  
Fax 781-740-2069  
2165 Meadowpine Blvd  
Mississauga, ON L5N 6H6  
Phone 905-542-0303  
Toll Free 800-387-3898  
Fax 905-542-1525  
Technical Support Hotline  
1-800-4-RIELLO  
1-800-474-3556  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weed Eater Trimmer 530087729 User Manual
Westinghouse Flat Panel Television WD40FX1450 User Manual
Westinghouse Power Hammer IL33 861 1 User Manual
Whirlpool Clothes Dryer GEW9250PW0 User Manual
Whirlpool Cooktop WBC430 User Manual
Whirlpool Microwave Oven GSC308 PRS00 User Manual
Woods Equipment Chipper S30CD User Manual
Xantech Switch HDMI4X4 User Manual
Xerox Printer Phaser 3260DI User Manual
Zanussi Washer ZT 1014 User Manual