WEBER
TM
FLAME
Natural Gas Fireplace Owner’s Guide
#39995
ƽ WARNING
ƽ WARNING
If the information in this manual is not
Improper installation, adjustment,
followed exactly, a fire or explosion may
alteration, service or maintenance can
result causing property damage, personal
cause injury or property damage. Read the
injury or loss of life.
installation, operating and maintenance
instructions thoroughly before installing
or servicing this equipment.
• Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
ƽ WARNING: FOR OUTDOOR USE ONLY.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do
These instructions are to be retained by the
not use any phone in your building.
consumer for future reference.
• Immediately call your gas supplier from
a neighbor’s phone.
• Follow the gas supplier’s instructions.
• If you cannot reach the gas supplier, call
the fire department.
This appliance is not a heater.
- Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
39995 US 03/16/05
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY / GENERAL INSTRUCTIONS
3
Weber-Stephen Products Co. (Weber®) hereby warrants to the ORIGINAL
PURCHASER of this Weber® gas fireplace that it will be free of defects in
material and workmanship from the date of purchase as follows:
•
These instructions will give you the minimum requirements for
assembling your Weber® gas fireplace. Please read the instructions
carefully before using your Weber® gas fireplace. Improper
assembly can be dangerous.
•
•
Not for use by children.
Young children should be carefully supervised when they are in the
area of the fireplace.
Children and adults should be alerted to the hazards of high surface
temperatures and should stay away to avoid burns or clothing
ignition.
Aluminum Castings, lifetime, 1 year paint
Porcelain Hood Section, 25 years
Burner, 10 years
•
Igniter, 3 years
All Remaining Parts, 3 years
•
•
•
Clothing or other flammable materials should not be hung from the
fireplace, or placed near the fireplace.
Any guard or other protective device removed for servicing the
fireplace must be replaced prior to operating the fireplace.
If there are local codes that apply to portable gas fireplaces, you
will have to conform to them. If there are no local codes, you must
conform to the latest edition of the National Fuel Gas Code: ANSI
Z 223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas and Propane
Installation Code.
when assembled and operated in accordance with the printed instructions
accompanying it.
Weber may require reasonable proof of your date of purchase. THERE-
FORE, YOU SHOULD RETAIN YOUR SALES SLIP OR INVOICE.
This Limited Warranty shall be limited to the repair or replacement of parts
that prove defective under normal use and service and which on examination
shall indicate, to Weber’s satisfaction, they are defective. Before returning
any parts, contact the Customer Service Representative in your area using
the contact information on our website. If Weber® confirms the defect and
approves the claim, Weber® will elect to replace such parts without charge.
If you are required to return defective parts, transportation charges must be
prepaid. Weber® will return parts to the purchaser, freight or postage prepaid.
This Limited Warranty does not cover any failures or operating difficulties due
to accident, abuse, misuse, alteration, misapplication, vandalism, improper
installation or improper maintenance or service, or failure to perform normal
and routine maintenance, including but not limited to damage caused by
insects within the burner tubes, as set out in this owner’s manual.
Deterioration or damage due to severe weather conditions such as hail,
hurricanes, earthquakes or tornadoes, discoloration due to exposure to
chemicals either directly or in the atmosphere, is not covered by this Limited
Warranty.
•
•
The fireplace and it’s individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
that system at test pressures in excess of 1/2 psi (3.5kPa).
The fireplace must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to or
less than 1/2 psi (3.5 kPa).
•
•
The pressure regulator supplied with the Weber® gas fireplace
must be used. This regulator is set for 4 inches of water column
(pressure).
This Weber® gas fireplace is designed for use with natural gas only.
Do not use with LP (Liquid Propane) gas. The valves, orifices, hose
and regulator are for NG gas only.
There are no other express warrants except as set forth herein and any ap-
plicable implied warranties of merchantability and fitness are limited in dura-
tion to the period of coverage of this express written Limited Warranty. Some
regions do not allow limitation on how long an implied warranty lasts, so this
limitation may not apply to you.
Weber® is not liable for any special, indirect or consequential damages.
Some regions do not allow the exclusion or limitation of incidental or conse-
quential damages, so this limitation or exclusion may not apply to you.
Weber® does not authorize any person or company to assume for it any other
obligation or liability in connection with the sale, installation, use, removal,
return, or replacement of its equipment; and no such representations are
binding on Weber®.
This Warranty applies only to products sold at retail.
WEBER-STEPHEN PRODUCTS CO.
Customer Service Center
1890 Roselle Road, Suite 308
Schaumburg, IL 60195
USA
For replacement parts call:
1-800-446-1071
©2003 The following trademarks are registered in the name of Weber-Stephen Products Co., an Illinois corporation, located at 200 East Daniels Road, Palatine, Illinois 60067
®
®
®
U.S.A. Australia; Smokey Joe, Weber, Kettle Silhouette , Genesis, Austria; Kettle Silhouette , Smokey Joe, Weber, Benelux; Kettle Silhouette , Smokey Joe, Weber, Compact
®
®
Grill Configuration, Botswana; Weber, Canada; Smokey Joe, Genesis, China; Kettle Silhouette , Denmark; Kettle Silhouette , Smokey Joe, Weber, Finland; Smokey Joe, France;
®
®
Kettle Silhouette , Smokey Joe, Weber, One-Touch, Germany; Smokey Joe, Weber, One-Touch, Greece; Smokey Joe, Ireland; Kettle Silhouette , Smokey Joe, Italy; Smokey
Joe, Weber, Japan; Smokey Joe, Weber, Korea; Smokey Joe, Weber, New Zealand; Weber, Smokey Joe, Nigeria; Weber, Norway; Smokey Joe, Weber, Portugal; Weber,
®
®
South Africa: Smokey Joe, Weber, Kettle Configuration, Spain; Smokey Joe, Weber, Sweden; Kettle Silhouette , Smokey Joe, Switzerland; Kettle Silhouette , Smokey Joe,
®
Weber, United Kingdom; Smokey Joe, Weber, Weber One-Touch, U.S.A..; Kettle Configuration, Kettle Silhouette , Smokey Joe, Weber, One-Touch, Firespice, Go-Anywhere,
U.S.A.;Kettle Configuration, Kettle Silhouette, Genesis, Flavorizer, Crossover, Flamgo, Performer, Rapidfire, Tuck ‘N Carry, Jumbo Joe, Bar-B-Kettle, Master-Touch, Spirit, Grill
®
Out, Summit, Platinum, 1-800-Grill-Out, Ranch, Matchless Flame, Zimbabwe; Weber, Kettle Configuration, Kettle Silhouette .
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL INSTRUCTIONS
4
®
ƽ
Use of this Weber fireplace with LP (Liquid Propane)
will void all product warranty and can result in a fire
or explosion, which can cause serious bodily injury,
CLEANING
ƽ WARNING: Turn your Weber® gas fireplace OFF and
wait for it to cool before cleaning.
For availability of replacement parts contact the Customer Service
Representative in your area using the contact information on our web
death, and damage to property.
•
•
Do not use with charcoal fuel or any other solid fuel.
Check that the burner ports are free from debris that might obstruct the
flow of combustion or ventilation air.
Outside surfaces - Use a warm soapy water solution to clean, then rinse
•
•
The areas around the natural gas supply must be free and clear from
debris.
with water.
Replacement pressure regulators and hose assemblies must be those
specified by the outdoor gas appliance manufacturer.
Logs - To clean soot off of the logs, remove them from fireplace and rinse
with a garden hose.
Note: Normal burning pattern will develop light soot on log set. If heavy
sooting occurs, refer to troubleshooting.
FOR INSTALLATION IN CANADA
These instructions, while generally acceptable, do not necessarily comply
with the Canadian Installation codes, particularly with piping above and
below ground. In Canada the installation of this appliance must comply
with local codes and/or Standard CAN/CGA-B149.2 (Installation Code for
Propane Burning Appliances and Equipment).
Do not use cleaners that contain acid, mineral spirits or xylene. Rinse
well after cleaning.
OPERATING
ƽ WARNING: Only use this fireplace outdoors in a well-
ventilated area. Do not use in a garage, building,
breezeway, gazebo or any other enclosed area.
®
ƽ WARNING: Your Weber gas fireplace shall not be
used under overhead combustible construction.
ƽ WARNING: Do not use the fireplace within 24 inches
of combustible materials, top, back or sides of the
fireplace.
ƽ WARNING: The upper portion of the fireplace gets hot
when in use. Do not leave unattended.
ƽ WARNING: Keep any electrical supply cord and the
fuel supply hose away from any heated surface.
ƽ WARNING: Keep the burner area clear of flammable
vapors and liquids such as gasoline, alcohol, etc., and
combustible materials.
STORAGE AND/OR NON USE
• The gas must be turned off at the natrual gas supply when the Weber® gas
fireplace is not in use.
• When the Weber® gas fireplace is stored indoors, the gas supply must be
DISCONNECTED.
• The Weber® gas fireplace should be checked for gas leaks and any ob-
structions in the burner tube before using. (See Sections: “Gas Instructions
and Operating Instructions.”)
• Check that the burner ports are free from debris that might obstruct the flow
of combustion or ventilation air.
• The Spider /Insect Screen should also be checked for any obstructions.
(See Section: "Maintenance.")
Download from Www.Somanuals.com. All Manuals Search And Download.
PARTS LIST
5
BASE - 1
CERAMIC LOGS - 8
BACK PANEL - 1
RAIN SHIELD - 3
HOOD VENT - 1
HOSE - 1
HOOD VENT
SUPPORT - 4
1/4 - 20 1/2”
CARRIAGE BOLT - 16
1/4 - 20 1/2” NUT - 16
SUPPORT BRACKET - 3
LAVA ROCKS
7/16” (11 MM)
WRENCH - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
EXPLODED VIEW
6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Download from Www.Somanuals.com. All Manuals Search And Download.
EXPLODED VIEW LIST
7
1. HOOD VENT
16. IGNITER BOX ASSEMBLY
2. 1/4 - 20 X 1/2” CARRIAGE BOLT
3. SUPPORT BRACKET
4. QUICK-DISCONNECT HOSE
5. 1/4 - 20 X 1/2” NUT
6. HOOD VENT SUPPORT
7. RAIN SHIELD
17. HUBCAP
18. BURNER PLATE
19. CONTROL PANEL
20. BURNER PLATE LEG
21. FIREBOX
22. LEG
8. REAR PANEL
23. NAMEPLATE ASSEMBLY
24. IGNITER ASSEMBLY
25. CONTROL KNOB
9. WASHER
10. 1/4 - 20 X 1/2” KEPS NUT
11. GAS TRAIN ASSEMBLY
12. WHEEL COVER
26. 1/4 - 20 1/2”
CARRIAGE BOLT
27. FIREBOX HANDLE
28. CERAMIC LOGS
29. MATCHLIGHT HOLDER
30. LAVA ROCKS
13. WHEEL
14. AXLE
15. WHEEL BRACKET
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSEMBLY
8
Assembly: Consumer - 40 Minutes.
*Professional - 30 Minutes.
4 (
)
1
2
ƽ Hand tighten only.
2 (
)
2 (
)
3
4
ƽ Hand tighten only.
ƽ Hand tighten only.
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSEMBLY
9
4 (
)
5
ƽ Hand tighten only.
Warning text on panel faces outward.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSEMBLY
10
4 (
)
7
8
2
1
ƽ Wrench tighten ALL nuts at this time.
ƽ Empty lava rocks onto cardboard
packing. Remove small debris.
ƽ Do not obstruct ignition box.
10
9
ƽ Do not empty bag of
lava rocks directly into
the fireplace. Doing so
could cause the burner
ports to clog.
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSEMBLY
11
Place ceramic logs in fireplace.
ƽ NEVER burn real logs in fireplace.
Always attach rain shields when not in
use and for storage.
11
12
13
ƽ DANGER
Do not operate fireplace untill ALL rain shields have
been removed. Failure to do so could result in a
fire or explosion which can cause serious bodily
injury or death, and damage to property.
Download from Www.Somanuals.com. All Manuals Search And Download.
GAS INSTRUCTIONS
12
INSTALL GAS SUPPLY
General Specifications for Piping
Gas supply
Shut off
Note - Contact your local municipality for building codes regulating
outdoor gas fireplace installations.
Inside wall
Outside wall
• Refer to AS5601 gas installations for piping and hose requirements.
• Refer to AS5601/AG 601, local authority, gas, electric, and other
relevant statutory regulations for use and installation.
• WE RECOMMEND THAT THIS INSTALLATION BE DONE BY A
PROFESSIONAL.
This is a typical installation
of a Weber® natural gas
fireplace. Local codes may
require different
Some of the following are general requirements taken from the latest
edition of the National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/
CGA-B149.1, see Natural Gas and Propane Installation Code for complete
specifications.
installations.
•
•
•
•
•
This fireplace is designed to operate at 4 inches of water column
pressure (.2526 psi).
The maximum inlet gas pressure for this fireplace is 7 inches of water
column pressure.
A manual shut-off valve must be installed outdoors, immediately ahead of
the quick disconnect.
An additional manual shut-off valve indoors should be installed in the
branch fuel line in an accessible location near the supply line.
The quick disconnect connects to a 3/8 inch NPT thread from the gas
source. The quick disconnect fitting is a hand-operated device that
automatically shuts OFF the flow of gas from the source when the
fireplace is disconnected.
f
Locking shut of
3
1
/ " Pipe
8
/ " Pipe
nipple
Quick
disconnect
2
nipple
•
The quick disconnect fitting can be installed horizontally, or pointing
downward. Installing the fitting with the open end pointing upward can
result in collecting water and debris.
Do Not Use
•
•
•
The dust covers (supplied plastic plugs) help keep the open ends of the
quick disconnect fitting clean while disconnected.
Pipe compound should be used which is resistant to the action of natural
gas when connections are made.
The outdoor connector must be firmly attached to rigid, permanent
construction.
ƽ WARNING: Do not route the 10 foot hose under a
deck. The hose must be visible.
Gas Line Piping
•
If the length of the line required does not exceed 50 feet, use a 5/8" O.D.
tube. One size larger should be used for lengths greater than 50 feet.
Gas piping may be copper tubing, type K or L; polyethylene plastic tube,
with a minimum wall thickness of .062 inch; or standard weight (schedule
40) steel or wrought iron pipe.
•
•
Copper tubing must be tin-lined if the gas contains more than 0.3 grams
of hydrogen sulfide per 100 cubic feet of gas.
•
•
Plastic tubing is suitable only for outdoor, underground use.
Gas piping in contact with earth, or any other material which may corrode
the piping, must be protected against corrosion in an approved manner.
Underground piping must have a minimum of 18" cover.
•
•
Installation and repair should be done by a qualified service person.
The fireplace should be inspected before use and at least annually by
a qualified service person. More frequent cleaning may be required
as necessary. It is imperative that control compartment, burners and
circulating air passageways of the fireplace be kept clean.
Test Connections
All connections and joints must be thoroughly tested for leaks in accordance
with local codes and all listed procedures in the latest edition of the National
Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/CGA-B149.1.
Download from Www.Somanuals.com. All Manuals Search And Download.
GAS INSTRUCTIONS
13
ƽ DANGER
Do not use an open flame to check for gas leaks. Be
sure there are no sparks or open flames in the area
while you check for gas leaks. This will result in a fire
or explosion which can cause serious bodily injury or
death and damage to property.
SIDE VIEW
a
(1)
CHECK THAT THE BURNER VALVE IS OFF
Valve is shipped in the OFF position, but you should check to be sure that
it is turned OFF. Check by pushing down and turning clockwise. If it does
not turn, it is off. Proceed to the next step. If it does turn continue turning it
clockwise until it stops, then it is off. Proceed to the next step.
(2)
CONNECT GAS SUPPLY
a) To connect gas hose at the supply: Slide back the collar of the quick
disconnect. Push male fitting of the hose into the quick disconnect, and
maintain pressure(1). Slide the collar closed(2). If it does not engage or lock,
repeat procedure.
b) To connect gas hose at the Fireplace: Slide back the collar of the
quick disconnect. Push male fitting of the fireplace connection into the quick
disconnect, and maintain pressure(1). Slide the collar closed(2). If it does not
engage or lock, repeat procedure.
TOP VIEW
b
(1)
Gas will not flow unless the quick disconnect is properly engaged.
ƽ WARNING: Make sure that the gas supply hose is
positioned so as to avoid damage from foot traffic or
other accidental damage.
(2)
Download from Www.Somanuals.com. All Manuals Search And Download.
GAS INSTRUCTIONS
14
CHECK FOR GAS LEAKS
(1)
ƽDANGER
Do not use an open flame to check for gas leaks. Be
sure there are no sparks or open flames in the area
while you check for leaks. Sparks or open flames will
result in a fire or explosion which can cause serious
bodily injury or death and damage to property.
(2)
ƽ WARNING: You should check for gas leaks every time
you disconnect and reconnect a gas fitting.
Note - All factory-made connections have been thoroughly checked for gas
leaks. The burner has been flame-tested. As a safety precaution however,
you should recheck all fittings for leaks before using your Weber® gas
fireplace. Shipping and handling may loosen or damage a gas fitting.
ƽ WARNING: Perform these leak checks even if your
(3)
fireplace was dealer or store assembled.
You will need: a soap and water solution, and a rag or brush to apply it.
To perform leak checks: Slide back the collar of the quick disconnect. Push
male fitting of the hose into the quick disconnect, and maintain pressure(1).
Slide the collar closed(2). If it does not engage or lock, repeat procedure.
Gas will not flow unless the quick disconnect is properly engaged.
Turn on gas supply.
Check for leaks by wetting the connections with the soap and water solution
and watching for bubbles. If bubbles form or if a bubble grows, there is a
leak.
(4)
(5)
Note - Since some leak test solutions, including soap and water, may be
slightly corrosive, all connections should be rinsed with water after checking
for leaks.
ƽ WARNING: Do not ignite burner when leak checking.
Download from Www.Somanuals.com. All Manuals Search And Download.
GAS INSTRUCTIONS
15
Check:
1) Bulkhead fitting-to-Regulator connection.
(1)
ƽ WARNING: If there is a leak at connections (1), turn
OFF the gas. DO NOT OPERATE THE FIREPLACE.
Contact the Customer Service Representative in your
area using the contact information on our web site.
®
2) Regulator-to-Quick disconnect fitting.
3) Fitting-to-quick disconnect connection.
4) Test point fitting
(2)
ƽ WARNING: The test point fitting should only be
loosened or removed by an authorized service person.
5) Quick disconnect-to-supply connection.
ƽ WARNING: If there is a leak at connection (2), (3), (4)
or (5), retighten the fitting by hand. Make sure the
quick disconnect fittings are properly seated. Recheck
for leaks with soap and water solution. If a leak
(3)
persists after these measures, turn OFF the gas. DO
NOT OPERATE THE FIREPLACE. Contact the Customer
Service Representative in your area using the contact
®
When leak checks are complete, turn gas supply OFF at the source and
rinse connections with water.
(4)
(5)
Table
10-1
Maximum Capacity of Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 0.5 psi or Less and a Pressure Drop of 0.3 Inch
Water Column. (Based on a 0.60 Specific Gravity Gas)
Nominal
Iron Pipe
Size
Internal
Diameter
(Inches)
Length of Pipe (Feet)
10
20
30
40
50
60
70
80
90
100
125
150
175
200
(Inches)
1/4
3/8
1/2
3/4
1
.364
.493
32
22
49
18
40
15
34
14
30
12
27
11
25
11
23
10
22
9
8
8
7
6
72
21
18
17
15
14
.622
132
92
73
63
56
50
46
43
40
38
34
31
28
26
.824
278
190
350
730
1100
2100
3300
5900
152
285
590
890
1650
2700
4700
9700
130
245
500
760
1450
2300
4100
8300
115
215
440
670
1270
2000
3600
7400
105
195
400
610
1150
1850
3250
6800
96
90
84
79
72
64
59
55
1.049
1.380
1.160
2.067
2.469
3.068
4.026
520
180
370
560
1050
1700
3000
6200
170
350
530
990
1600
2800
5800
160
320
490
930
1500
2600
5400
150
305
460
870
1400
2500
5100
130
275
410
780
1250
2200
4500
120
250
380
710
1130
2000
4100
110
225
350
650
1050
1850
3800
100
210
320
610
980
1700
3500
1 1/4
1/12
2
1050
1600
3050
4800
8500
2 1/2
3
4
17500 12000
© 1997 National Fire Protection Association, Inc,. and International Approval Services - U.S., Inc. All Rights Reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
16
LIGHTING
Summary lighting instructions are on the control panel.
1.
ƽ WARNING: Check hose before each use of fireplace
for nicks, cracking, abrasions or cuts. If the hose
is found to be damaged in any way, do not use the
fireplace. Replace using only Weber® authorized
replacement hose. Contact the Customer Service
Representative in your area using the contact
6.
5.
®
4.
2.
com .
1) Remove rain shields.
ƽ DANGER
Failure to remove rain shields while igniting the
fireplace’s burners, or not waiting 5 minutes to allow
the gas to clear if the fireplace does not light, may
result in an explosive flame-up which can cause
serious bodily injury or death and damage to property.
2) Make sure the burner control knob is turned OFF. (Push control knob
down and turn clockwise to ensure that it is in the OFF position.)
3) Turn the gas supply valve on.
3.
ƽ WARNING: Do not lean over the open fireplace. Keep
your face and body at least one foot away from the
logs when lighting the fireplace. Leaning over a lit
fireplace could cause damage to body and personal
property.
TO EXTINGUISH
Push in the burner control knob and turn clockwise to the OFF posi-
tion. Turn gas supply OFF at the source. When unit has cooled, replace
rain shields.
4) Push burner control knob in and turn counter-clockwise to START/HI.
5) Push in igniter several times, until burner is lit.
6) Check that the burner is lit.
ƽ WARNING
ƽ WARNING:
Inspect the burner before each use of the fireplace. If
it is evident that the burner is damaged in any way, it
must be replaced with a burner specified by the manu-
facturer prior to the fireplace being turned on. Failure
to comply with these measures could result in an ex-
plosive flame-up which can cause serious bodily injury
or death and damage to property.
If the burner does not light, turn the burner control
knob to OFF and wait 5 minutes to let the gas clear
before you try again or try to light with a match. Failure
to comply with these measures could result in an
explosive flame-up which can cause serious bodily
injury or death and damage to property.
Note: Normal burning pattern will develop light soot on log set. If heavy
sooting occurs, refer to troubleshooting.
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
17
MANUAL LIGHTING
1) Remove rain shields.
1.
ƽ DANGER
Failure to remove rain shields while igniting the
fireplace’s burners, or not waiting 5 minutes to allow
the gas to clear if the fireplace does not light, may
result in an explosive flame-up which can cause
serious bodily injury or death.
6.
4.
5.
2.
2) Make sure the burner control knob is turned OFF. (Push control knob
down and turn clockwise to ensure that it is in the OFF position.)
3) Turn the gas supply valve on.
ƽ WARNING: Do not lean over the open fireplace. Keep
your face and body at least one foot away from the
logs when lighting the fireplace.
4) Insert match holder with lit match near the center of the burner area.
5) Push in igniter several times, until burner is lit.
6) Check that the burner is lit.
ƽ WARNING: If the burner does not light, turn the
burner control knob to OFF and wait 5 minutes to let
the gas clear before you try again or try to light with a
match.
3.
Note: Normal burning pattern will develop light soot on log set. If heavy
sooting occurs, refer to troubleshooting.
TO EXTINGUISH
Push in the burner control knob and turn clockwise to the OFF posi-
tion. Turn gas supply OFF at the source. When unit has cooled, replace
rain shields.
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
18
PROBLEM
Burner burns with a dark orange
CHECK
CURE
Inspect Spider / Insect Screen for pos-
flame, in conjunction with heavy soot- sible obstructions. (Blockage of holes.)
Clean Spider / Insect Screen. (See Section
“Annual Maintenance”)
ing.
Burner does not light, or flame is low
in HIGH position.
Is fuel hose bent or kinked?
Straighten fuel hose.
Is igniter functioning properly?
Is the igniter box blocked?
Replace igniter (see contact info. below).
Remove obstructions from igniter box (see
pg. 10, Step 11 of “Assembly” Section).
Burner flame pattern is erratic. Flame
is low when burner is on HIGH. Flames
do not ignite all burner holes.
Are burner holes blocked?
Clean burner holes. (See Maintenance Sec-
tion.)
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
19
WEBER® SPIDER / INSECT SCREEN
Your Weber® gas fireplace, as well as any outdoor gas appliance, is a target
for spiders and other insects. They can nest in the venturi section (1) of the
burner tube. This blocks the normal gas flow, and can cause the gas to flow
back out of the air shutter. This could result in a fire, causing serious damage
to your fireplace.
Thus, it is imperative that control compartment, burners and air vents
of the appliance be kept clean.
The burner tube air shutter is fitted with a stainless steel screen (1) to
prevent spiders and other insects access to the burner tube through the air
shutter openings.
We recommend that you inspect the Spider/Insect screen at least once
a year. (See Section “Annual Maintenance”.) Also inspect and clean
the Spider/Insect screen if any of the following symptoms should ever
occur:
1) The smell of gas in conjunction with the burner flame appearing yellow
and lazy.
2) Burner does not ignite.
ƽ DANGER
(1)
Failure to correct the above mentioned symptoms may
result in a fire, which can cause serious bodily injury
or death, and cause damage to property.
(1)
ANNUAL MAINTENANCE
Inspection and cleaning of the Spider/Insect screen
Brush the spider/insect screen, lightly, with a soft bristle brush (i.e. an old
toothbrush).
ƽ CAUTION: Do not clean the spider/insect screen with
hard or sharp tools. Do not dislodge the spider/insect
screen or enlarge the screen opening.
If the spider/insect screen becomes damaged or cannot be cleaned, call
Weber-Stephen Products Customer Service for replacement parts.
MAIN BURNER CLEANING PROCEDURE
Turn off the gas supply.
1) Remove rain shields.
2) Remove logs and lava rocks.
3) Examine burner holes for blockage.
4) Use a soft bristle brush to remove leaves or other debris.
ƽ CAUTION: Do not enlarge the burner holes when
cleaning.
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
20
MAIN BURNER FLAME PATTERN
The Weber® gas fireplace burner has been factory set for the correct air and
gas mixture. A correct flame pattern is:
• A yellow to light-orange flame
An incorrect flame pattern is:
• A dark orange flame
• Smoke-producing flame
If the flames appear to be darker orange throughout the burner, sooting
occurs, or smoke is produced; follow the burner and spider screen cleaning
procedures.
IGNITION SYSTEM
If the Ignition System fails to ignite the burner, light manually. If Manual igni-
tion is successful, then check the Ignition System.
(3)
•
Check that both the white (2) and black (3) ignition wires are attached
properly.
•
•
Check that the igniter button pushes in completely and returns.
Check to see if the igniter is loose in the frame. Tighten if necessary.
If the Ignition System still fails to ignite the burner, see Manual Lighting pro-
cedure and contact your dealer.
(2)
Printed in U.S.A.
Download from Www.Somanuals.com. All Manuals Search And Download.
|