Waterpik Technologies Outdoor Shower CF 200 User Manual

1. Remove old showerhead. Clean pipe threads thoroughly.  
Operation  
2. Attach the flexible shower arm collar to the  
showerhead, being careful to align  
the threads.  
Clean the filter screen at least once a year, or when you notice a drop in  
water pressure. To remove, unscrew the nut from the pipe. Remove the  
screen by turning it counter-clockwise (pliers may be used) and rinse.  
If you remove the flow regulator, be sure you reinstall it with the black O-ring  
facing out.  
drenching rain showerhead  
• Cleaning is required when mineral deposits appear on the spray holes to  
maintain proper working conditions.  
• Clean the flexible nozzles by rubbing with a finger or soft bristled toothbrush.  
Spray Change  
Button  
• Do not clean or rinse any part with harsh chemicals, heavy-duty cleaners or  
abrasives. This may damage parts or finish and may void the warranty.  
Shower  
Arm Nut  
Limited Lifetime Warranty  
Collar  
Flexible Arm  
3. While installing, support the showerhead and hold onto the  
nut rather than the cover. Turn only the nut to tighten.  
Do not twist the flexible shower arm covering  
during installation. (This could damage the  
covering and/or cause the product to  
malfunction.) Take care in aligning  
the nut to the shower pipe so you  
do not cross threads.  
Models:  
CF-200  
CF-201  
CF-201C  
CF-203C  
CF-209C  
CF-261  
Water Pik, Inc. warrants to the original purchaser of this product that  
it is free from defects in material and workmanship for as long as the  
original purchaser owns this product. Water Pik, Inc. will at our election,  
repair or replace any part of the product which in our opinion is defec-  
tive, provided that the product has not been abused, misused, altered  
or damaged after purchase. (This includes damage due to use of tools  
or harsh chemicals.) In the event an item has been discontinued we will  
replace with what we deem to be the closest product. Water Pik, Inc.  
is not responsible for labor charges, installation, or other consequential  
cost. The responsibility of Water Pik, Inc. shall not exceed the original  
purchase price of the product. This warranty gives you specific legal  
rights. You may also have other rights that vary where you reside. Save  
your receipt as proof of purchase is required for warranty action.  
Spray Change  
Button  
Bracket  
4. Tighten the shower nut onto the pipe  
securely by hand. Do not over  
tighten or use pliers.  
CF-263C  
Adapter  
5’ hose  
5. Slowly turn on cold water and check for leaks. If leaks occur, retighten  
all connections.  
6. Do not use excessive force in positioning the showerhead and/or arm.  
Instruction Manual  
U.S. Patent Numbers: 5,865,378; 5,997,047 (Lic);  
6,164,570 (Lic); 6,626,210; 6,629,651;6,641,057; D440,641;  
D452,897; D485,887  
7. If the showerhead is not maintaining its position, re-tighten the  
showerhead collar and shower arm nut.  
Flow Control  
Waterpik® showerheads are equipped with an OptiFLOW® regulator that  
limits maximum water flow to 2.5 gallons per minute at 80 psi  
as mandated by U.S. federal law.  
Hand-Held Installation  
Have any questions or need assistance?  
1. Remove old showerhead. Clean pipe threads thoroughly.  
2. Slightly loosen swivel collar on bracket.  
3. Hand tighten pivot ball to pipe.  
If in the U.S., call our toll-free  
Customer Assistance Line,  
1-800-525-2774  
If outside the U.S., write us at:  
Water Pik, Inc.  
1730 East Prospect Road  
Fort Collins, CO 80553-0001  
USA  
In areas with extremely low water pressure, causing  
the shower water flow to be unsatisfactory, the  
flow regulator may be removed to improve  
the water flow in the showerhead.  
To remove, unscrew  
4. Hand tighten adaptor to showerhead.  
5. Hand tighten hose to adapter and bracket.  
6. Place showerhead in bracket.  
filter screen by turning  
Waterpik®, Waterpik® (stylized), Cascadia®, and OptiFLOW® are  
registered trademarks of Water Pik, Inc.  
© 2006 Water Pik, Inc.  
Nut  
counterclockwise.  
Remove regulator  
with needle-nose  
pliers and replace  
filter screen.  
Flow Regulator  
(black O-ring faces out)  
Filter Screen  
Washer  
Water Pik, Inc.  
1730 East Prospect Road, Fort Collins, CO 80553-0001 USA  
Flow Regulator  
Filter  
Screen  
Operation  
To change settings, from  
Flexible Installation  
Spray Change Button  
either the full-body spray  
or the concentrated power  
spray, push the spray  
change button at the base  
of the showerhead so it  
extends to the opposite  
side of its current position.  
Your new showerhead will fit a standard 1/2” shower arm. Do not  
attach this product to a plastic shower arm since it may not provide  
adequate support.  
Tools are not required. Do not use pipe tape or any other sealants when  
installing the showerhead. These materials are not necessary and may cause  
the nut to loosen prematurely. Hand tightening is sufficient to secure the  
shower thread. Make sure the washer is in the end of the nut.  
FN 20007764-F AB  
Spray Change Button  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tascam Network Card IF CB User Manual
Toro Lawn Mower 14AP80RP544 User Manual
Toshiba Barcode Reader B EV4T SERIES User Manual
Toshiba Personal Computer M10 User Manual
Toshiba Printer B 570 QQ User Manual
TP Link Network Card TF 3239D User Manual
Tricity Bendix Electric Pressure Cooker SE305 User Manual
Uniden Cordless Telephone CEZAI 998 User Manual
Uniden Headphones D1760 11 User Manual
Vivotek Stereo Receiver RX7101 User Manual