		 R 
					Item no. 2012   
					Industriaal Line   
					TM   
					WATT   
					5000   
					User's Manual   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Industrial Line 5000 Watt Power Inverter by Wagan Tech   
					USER’S MANUAL — Please read before using this equipment.   
					_______________________________________________________________________________________________________________________   
					INSTALLATION   
					Where to install   
					Grounding   
					The power inverter has a lug on the rear panel marked   
					“chassis ground”. This is to connect the chassis of the   
					power inverter to the ground. The ground terminals in   
					the AC outlets on the front panel of the inverters are also   
					connected to the ground lug.   
					The power inverter should be installed in a location that   
					meets the following requirements:   
					a. Dry- Do not allow water to drip or splash onto the   
					inverter   
					b. Cool- Ambient air temperature should be between   
					0C and 40C, the cooler the better   
					c. Ventilation- Allow at least 2 inches of clearance   
					around the inverter for airflow. Ensure the ventilation   
					openings on the rear and bottom of the unit are not   
					obstructed.   
					d. Safety- Do not install the inverter in the same   
					compartment as batteries or in any compartment   
					capable of storing flammable liquids such as   
					gasoline.   
					The chassis ground lug must be connected to the   
					grounding point, which will vary depending on where the   
					power inverter is installed. In a vehicle, connect the   
					chassis ground to the chassis of the vehicle. In a boat,   
					connect to the boat’s grounding systems. In a fixed   
					location, connect the chassis ground lug to earth.   
					The neutral (common) conductor the power inverter AC   
					output circuit is connected to the chassis ground.   
					Therefore, when the chassis is connected to the ground,   
					the neutral conductor will also be grounded. This   
					conforms to the national electrical code requirements the   
					separately derived AC sources (such as inverters and   
					generators) have their neutral tied to ground in the same   
					way that the neutral conductor from the utility line to   
					ground at AC breaker panel.   
					Cables   
					DC to AC inverters requires high amperage/low   
					voltage DC power to low amperage/high voltage   
					AC power. To operate properly connect inverter DC   
					input terminals direct to battery with heavies wire   
					available see chart below:   
					Caution   
					The negative DC input of the power inverter is   
					connected to the chassis. Do not install the power   
					inverter in a positive ground DC system. As positive   
					ground DC system has the positive terminal of the   
					battery connected to the chassis of the vehicle or to the   
					ground point.   
					3 
					© 2003 Wagan Corporation.   
					All Rights Reserved.   
					Wagan and Wagan.com are trademarks used by Wagan Corporation.   
					
					Printed in China   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Industrial Line 5000 Watt Power Inverter by Wagan Tech   
					USER’S MANUAL — Please read before using this equipment.   
					_______________________________________________________________________________________________________________________   
					QUICK HOOK UP AND TESTING   
					load into the AC receptacle on the front panel of the   
					inverter. Leave the test load switch off.   
					If you would like to quickly hook up the power inverter   
					and check its performance before going ahead with your   
					installation, please follow these guidelines:   
					8. Set power inverter switch to the ON position and   
					turn the test load on, the inverter should supply   
					power to the load. If you plan to measure the true   
					output R.M.S. voltage of inverter, a meter such as   
					FLUKE 87A, BACKMAN 4410 or TRIPLETT 4200   
					must be used.   
					1. Unpack and inspect the power inverter, check to see   
					that the power switch in the OFF position.   
					2. Connect the cable to the power input terminals on   
					the rear panel of power inverter. The red terminal is   
					positive (+) and black terminal is negative (-).   
					Connect the cable into the terminals and tighten the   
					wing nut to clamp the wires securely.   
					CAUTION:   
					• 
					DO NOT USE THE INVERTER IN A POSITIVELY   
					GROUNDED VEHICLE.   
					3. Connect the cable from the negative terminal of the   
					inverter to the negative terminal of the power source.   
					Make a secure connection.   
					RECOMMENDATION   
					• 
					If the power inverter makes a beeping sound, turn   
					OFF the power inverter and disconnect all   
					appliances from inverter and disconnect the inverter   
					from power supply. The beeping sound is simply the   
					low battery warning, which indicates that the voltage   
					of the battery power supply is getting low. Please   
					restart the vehicle engine before operating the   
					power inverter.   
					Caution   
					Loosely tightened connectors result in excessive   
					voltage drop and may cause overheated wires and   
					melted insulation.   
					4. Before proceeding further, carefully check that the   
					cable you have just connected connects from the   
					negative terminal of inverter to the negative output   
					terminal of the power source.   
					• 
					• 
					When you are not using the inverter, turn the power   
					switch to OFF and disconnect the inverter from   
					power supply.   
					Disconnect the inverter when starting the vehicle’s   
					engine.   
					5. When connecting the inverter directly to your battery   
					terminals, it is important to connect with right polarity   
					(connect ♁ from inverter to ♁ of battery terminal   
					and connect ⊖ from inverter to ⊖ of battery terminal)   
					CAUTION:   
					THE FOLLOWINGS OPERATION WILL DAMAGE AND   
					VOID THE WARRANTY OF THE INVERTER:   
					Warning   
					You may observe a spark when you make this   
					connection since current may flow to charge   
					capacitors in the power inverter. Do not make this   
					connection in the presence of flammable fumes, as   
					explosion or fire may result.   
					• 
					REVERSE POLARITY BY CONNECTING THE   
					WIRES TO THE INCORRECT TERMINALS.   
					CONNECTING THE BATTERY CHARGER TO   
					REPLENISH BATTERY WITHOUT   
					• 
					DISCONNECTING THE INVERTER FIRST.   
					CONNECTING THE INVERTER TO POWER   
					SOURCE GREATER THAN 15-VOLT DC.   
					OPERATING THE INVERTER AND BATTERY IN   
					OR AROUND WATER.   
					• 
					• 
					6. Set the power switch to the ON position. Check the   
					meters and indicators on the front panels of the   
					inverters. The voltage bar graph should indicate 11   
					to 14 volts, depending on the voltage of the power   
					source. If it does not, check your power source and   
					the connections to inverter. The other indicators   
					should be off.   
					7. Set power inverter switch to the OFF position, the   
					indicator lights may blink and the internal alarm may   
					sound momentarily. This is normal. Plug the test   
					4 
					© 2003 Wagan Corporation.   
					All Rights Reserved.   
					Wagan and Wagan.com are trademarks used by Wagan Corporation.   
					
					Printed in China   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Industrial Line 5000 Watt Power Inverter by Wagan Tech   
					USER’S MANUAL — Please read before using this equipment.   
					_______________________________________________________________________________________________________________________   
					MEASURING THE AC VOLTAGE   
					SAFETY PRECAUTION   
					The output waveform of the AC inverter is a MODIFIED   
					SINEWAVE. To measure the AC output voltage, you   
					must use a TRUE RMS VOLTMETER.   
					Do not open the case of the inverter. The high voltage   
					inside the unit is the same type of power as your   
					electrical outlets at home.   
					Do not let the cord of the inverter or any appliance’s cord   
					get wet.   
					Do not operate the inverter in or around water. The   
					voltage of the unit makes electrical shock hazard if   
					operated in wet conditions.   
					Do not connect the AC inverter directly to another AC   
					power source.   
					Keep it away from children, the inverter produces power   
					just like your AC wall outlets at home and should be   
					treated seriously.   
					RECOMMENDED BATTERY CONFIGURATION FOR   
					HEAVY-DUTY APPLICATION   
					Allow at least 2 inch of clearance around the inverter for   
					airflow.   
					If you operate the inverter in a moving vehicle, you need   
					to secure the inverter to prevent it from shifting around   
					while the vehicle is moving.   
					If there is anything wrong with the inverter, disconnect all   
					of the power.   
					Heavy-duty alternators rated above 120 Amps should be   
					used and they are available from RV, marine or auto   
					parts suppliers. These alternators are designed to   
					directly replace standard alternators but produce the   
					higher current and voltage required to charge multiple   
					battery systems.   
					An isolator is used to separate the vehicle’s system   
					batteries and the auxiliary batteries.   
					We recommend using the same deep cycle type of   
					batteries in the battery banks.   
					Notes   
					The above system should be installed properly. You   
					need to contact the RV or auto experts for some   
					instructions.   
					5 
					© 2003 Wagan Corporation.   
					All Rights Reserved.   
					Wagan and Wagan.com are trademarks used by Wagan Corporation.   
					
					Printed in China   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Industrial Line 5000 Watt Power Inverter by Wagan Tech   
					USER’S MANUAL — Please read before using this equipment.   
					_______________________________________________________________________________________________________________________   
					TROUBLESHOOTING   
					HEAT DISPERSAL   
					The inverter generates heat while it is working. This is   
					not a malfunction. However, if the inverter gets too hot   
					while working, it will turn off by itself.   
					Position the inverter where air flows freely around it to   
					allow the heat to disperse.   
					The inverter’s thermal protection prevents it from   
					operating when its temperature exceeds 130 ± 10 °F / 55   
					± 5 °C.   
					Condition   
					Solution   
					Poor contact   
					Battery voltage is   
					too low   
					Clean contact parts thoroughly   
					Start the engine to recharge the   
					battery. Replace the battery if   
					needed.   
					Shutdown on   
					overload   
					Reduce the wattage of inverter’s load   
					Thermal shutdown Allow the inverter to cool down by   
					reducing the load or turn it off for a   
					SPECIFICATION   
					while.   
					Receptacle has no Check the receptacle wiring.   
					power   
					Name   
					Description   
					12V (10-15V) DC   
					Input   
					Output   
					115V AC   
					MAINTENANCE   
					Output waveform   
					Continuous power   
					Surge power   
					Modified Sine Waveform   
					5000 Watt   
					10000 Watt   
					Approx. 90 %   
					< 0.3 A   
					10.5 ± 0.5 V DC   
					10 ± 0.5 V DC   
					4 outlets of 3-prong   
					DC input ON/OFF control   
					20x9x7 in³   
					Very little maintenance is required to keep the inverter   
					operating properly.   
					Efficiency   
					No load current   
					Battery low alarm   
					Battery low shutdown   
					AC output socket   
					Power switch   
					DESCRIPTION   
					10000W Peak Power — allow you to power appliances   
					that require a large amount of initial (peak) power to   
					work (such as many TVs and motor-power equipments).   
					Dimensions   
					Net Weight   
					22 lb   
					Low Battery Alarm — the inverter sounds an audible   
					alarm then turns itself off if the source battery becomes   
					too low.   
					NOTE   
					All specifications are typical at nominal line, half load,   
					and 77° F / 25° C unless otherwise noted. Specifications   
					are subject to change without notice.   
					Auto Shutdown/Reset Protection — the inverter shuts   
					itself down to protect from low battery drained.   
					Overload/Short Circuit Protection — the inverter   
					automatically turns itself off if the connected load is too   
					high or if it shorts.   
					Fuse — the inverter comes with fuse/s already installed.   
					4 AC Outlets — allows you to power up many   
					appliances at the same time.   
					6 
					© 2003 Wagan Corporation.   
					All Rights Reserved.   
					Wagan and Wagan.com are trademarks used by Wagan Corporation.   
					
					Printed in China   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				WAGAN Corp. Limited Warranty Registration Form   
					All WAGAN Corporation products are warranted to the original purchaser of this product.   
					Warranty Duration: This product is warranted to the original purchaser for a period of one (1)Year   
					from the original purchase date, to be free of defects in material and workmanship. WAGAN   
					Corporation disclaims any liability for consequential damages. In no event will WAGAN   
					Corporation be responsible for any amount of damages beyond the amount paid for the product   
					at retail. In the even of a defective item, please ship the item, prepaid, with a complete   
					explanation of the problem, your name, address and daytime phone number. WAGAN   
					Corporation will, at its option, replaces or repair the defective part. This warranty is void if the   
					product has been damaged by accident, in shipment, unreasonable use, misuse, neglect,   
					improper service, commercial use, repairs by unauthorized personnel or other causes not arising   
					out of defects in materials or workmanship. This warranty is effective only if the product is   
					purchased and operated in the USA and does not extend to any units which have been used in   
					violation of written instructions furnished.   
					Warranty Disclaimers: This warranty is in-lieu of all warranties expressed or implied and no   
					representative or person is authorized to assume any other liability in connection with the sale of   
					our products. There shall be no claims for defects or failure of performance or product failure   
					under any theory of tort, contract or commercial law including, but not limited to negligence,   
					gross negligence, strict liability, breach of warranty and breach of contract.   
					Warranty Performance: During the above one (1)Year warranty period, a product with a defect   
					will be replaced with a comparable model when the product is returned to WAGAN Corporation   
					with an original store receipt. The replacement product will be in warranty for the balance of the   
					one (1)Year warranty period.   
					Please activate my limited warranty for WAGAN Corp.5000 Watt Industial Power Inverter   
					Enclosed copy of original sales receipt.   
					Name   
					Mail Address   
					City   
					State, Zip Code   
					Item Purchased 5000 Watt Industrial AC to DC Power Inverter   
					Stores Name   
					Date of Purchase   
					Signature   
					Date   
					All WAGAN Corporation Products must be registered within (30) days of purchased to activate this warranty.   
					Mail the complete registration form, along with a copy of the original receipt to:   
					Attn: Customer Service   
					WAGAN Corporation   
					3589Yale Way   
					Fremont, CA 94538   
					c 2003 WAGAN Corp.   
					7 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |