Vulcan Hart Electric Steamer VSC2 User Manual

INSTALLATION &  
OPERATION MANUAL  
VSC SERIES STEAMERS  
WITH STEAM COIL REGENERATOR  
MODEL  
VSC2  
VSC3  
MODELVSC2  
For additional information on Vulcan-Hart Company or to locate an authorized  
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791  
FORM 30914 Rev. A (Jan. 2003)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation, Operation and Care of  
VSC SERIES STEAMERS  
With Steam Coil Regenerator  
SAVE THESE INSTRUCTIONS  
GENERAL  
Model VSC2 and VSC3 Steamers have two or three pressurized steaming compartments for cooking  
vegetables, fish, eggs and other foods.  
The heat exchanger in the cabinet base requires approximately 200 lb per hour of steam at 30 to 50 psi.  
(Refer to Steam Connection.)  
Accessory 12" x 20" stainless steel pans are available, solid or perforated, in 2.5", 4" and 6" depths.  
Each compartment has a 0 to 60 minute timer. (The buzzer requires manual shutoff.) Doors cannot be  
opened during pressurized cooking.  
An optional steam take-off connection (3/4" NPT) can provide steam for adjacent equipment.  
ACCOMMODATION  
NUMBER OF PANS PER  
TOTAL NUMBER OF PANS  
COMPARTMENT  
MODEL COMPARTMENTS  
2.5" Depth 4" Depth  
6" Depth  
4
2.5" Depth  
4" Depth  
6" Depth  
VSC2  
VSC3  
2
3
16  
24  
8
8
4
2
12  
6
– 3 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
UNPACKING  
Immediately after unpacking, check for possible shipping damage. If the steamer is found to be  
damaged, save the packaging material and contact the carrier within 15 days of delivery.  
LOCATION  
Before installing, verify that the electrical supply agrees with the specifications on the data plate.  
Position the steamer in its final location. Check that there are sufficient clearances to service the  
controls, for door swings, etc., so there will be no problem in making the required supply and drain  
connections.  
Allow enough space between any other piece of equipment or a wall for service access. Service for  
the controls for the upper steamer compartments requires access to the upper left side panel. Service  
on the cabinet base may require access to the left and/or right side panels.  
INSTALLATION CODES AND STANDARDS  
In the United States, the steamer must be installed in accordance with:  
1. State and local codes.  
2. National Electrical Code, ANSI/NFPA No. 70 (latest edition). Copies may be obtained from the  
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
3. NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available from the  
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
LEVELING  
Using a spirit level or pan of water, level the appliance; then elevate the right side about 1/8" (3 mm)  
to assure proper compartment drainage. After installation, bolt and anchor the appliance securely to the  
floor. Seal bolts and rear flanged feet with an NSF approved sealer (Silastic or equivalent).  
EXHAUST HOOD  
An exhaust system should be located directly above the steamer to exhaust steam and heat generated  
by the steamer.  
– 4 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PLUMBING CONNECTIONS  
WARNING: PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY  
AND PLUMBING CODES.  
Water Supply Connection  
The water filter, provided, must be installed in the water supply line going to the filtered water inlet or  
your steamer warranty may be voided. For incoming water supply line pressures, refer to the water filter  
manual shipped with the water filter. Follow the recommendations contained in it. Water pressure to the  
steamer should be 20 to 60 psi.  
Water Requirements  
Proper water quality can improve the taste of the food prepared in the steamer, reduce liming in the  
steam generator and extend equipment life. Local water conditions vary from one location to another.  
Ask your municipal water supplier for details about your local water supply before installation.  
Recommended water parameters are included in the water filter manual shipped with the steamer;  
follow the recommendations contained in it.  
Presence of sediment, silica, excess chlorides or other dissolved solids may lead to a recommendation  
for alternate form(s) of water treatment. Be sure to test the water with the test strip and register the  
results using the registration card or by visiting vulcanhart.com.  
Drain Connection(s)  
The steamer drain should be piped to a floor drain near the steamer. There should be no solid drain  
connection; an open gap between the steamer and the floor drain is required.  
Draining Requirements  
Temperatures in the boiler can reach as high as 240°F (116°C). Local codes will require that the  
temperature of the drain water be 140°F (60°C) or lower. At the end of the day when purging the boilers,  
some provision for lowering the water temperature must be provided by the user or installer to meet this  
code requirement.  
STEAM TAKE-OFF CONNECTION (Optional)  
When connecting adjacent equipment to the steam take-off connection (3/4" NPT), follow the equipment  
manufacturer’s instructions. Steam capacity should be carefully evaluated. If the optional steam take-  
off connection is provided on your steamer and is not connected to adjacent equipment, it should be  
plugged or capped.  
– 5 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STEAM CONNECTION  
An adequate amount of steam must be delivered to the steamer to assure consistent steam cooking.  
Where possible, supply the steamer with a separate line from the steam source. If the steamer must  
be supplied from a line supplying other appliances, the pipe sizes and pressure must be verified.  
REQUIRED STEAM INPUT  
Model VSC2  
70 lbs/hr  
Model VSC3  
105 lbs/hr  
Allow for elbows, pipe length and valves when calculating pressure loss (see example below).  
Supply only clean, dry steam to the steamer. Water can condense in the supply line during idle periods,  
which will impede the flow of steam. The steam supply line should be level or run slightly downward  
toward the steamer, and a Ball Float Trap should be installed near the steamer to drain out condensed  
steam from the supply line (Fig. 1).  
Fig. 1  
STEAM LINE—PRESSURE LOSS EQUIVALENTS  
Equivalent Loss in Linear Feet  
Pipe Size  
Loss Rate  
Delivery Rate (30 psi at steamer)  
90°  
1 psi/7.5 feet 1.8 feet  
1 psi/10 feet 2.2 feet  
Angle Valve  
10 feet  
Globe Valve  
18 feet  
3/4" ID  
1" ID  
165 lbs/hr  
285 lbs/hr  
12 feet  
23 feet  
Example: A supply line with 1" diameter pipe has a total of 50' of pipe, three elbows and one globe valve.  
The total equivalent length = 50' + 3 x 2.2' + 23' = 79.6'. Multiply times the loss rate of 1 psi/10' yields  
a pressure loss of about 8 psi. Therefore, 40 psi at the source would deliver 32 psi at the steamer.  
If the supply line were 3/4" diameter pipe, the total equivalent length = 50' + 3 x 1.8' + 18' = 73.4'. Multiply  
times the loss rate of 1 psi / 7.5 feet yields a pressure loss of about 10 psi. Therefore, 40 psi at the source  
would deliver 30 psi at the steamer.  
– 6 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL CONNECTIONS  
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE  
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL  
ELECTRICAL CODES.  
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW  
LOCKOUT / TAGOUT PROCEDURES.  
Refer to the electrical diagram located behind the access panel or cabinet door on the steamer.  
Service Connections  
Fig. 2  
– 7 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
WARNING: THE STEAMER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING,  
CLEANING OR SERVICING THE STEAMER.  
COMPARTMENT CONTROLS (Fig. 3)  
Fig. 3  
Timer (0 to 60 minutes) - Sets the steam time for the compartment.  
Indicator Light  
- Timed cycle is in progress when lit.  
Selector Switch  
Operating Handle  
- Pressurized means top compartment operates at 6 psi.  
- Pull out to send steam to the compartment, lock the door and enable  
operation.  
Push in to silence buzzer at end of cycle.  
Door Latch  
- Holds door closed and prevents door from fully opening until  
operating handle is pushed in. Move the door latch to the left to fully  
open the door after steam and condensate drain (1 minute). The  
handwheel is turned fully counterclockwise.  
Handwheel  
- Turn clockwise to seal door at start of cycle. After pressure release  
at end of cycle, turn counterclockwise to open.  
Buzzer (not shown)  
Pressure Gauge  
- Sounds an audible signal when timer cycle is complete. To silence  
buzzer, push in operating handle.  
- Indicates steam pressure. Reads 6 psi with compartments inactive  
and 4.5 to 6 psi during a cooking cycle.  
– 8 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STEAM REGENERATOR CONTROLS (Inside Cabinet)  
Main Power Switch  
- ON begins generation of clean steam by the heat exchanger. You  
should allow 20 minutes to generate steam.  
OFF opens the Automatic Blowdown valve. This empties the heat  
exchanger by releasing both water and steam to the drain. This  
should be done at least once daily to remove sediment, lime or  
scale.  
Pilot Light (green)  
- Indicates main power is ON.  
Boiler Pressure Gauge  
- Should read 9 to 13 psi during operation and 0 psi during shutdown.  
Water Level Sight Glass - This assembly indicates the water level, and should be checked at  
least once a day. The correct water level is one-half the height of  
the glass. Extreme murkiness indicates the boiler should be  
cleaned.  
Water Level Control  
- While ON, briefly open the manual valve under the float chamber  
once each week to remove any sediment that might accumulate  
and seize the floats. The float chamber is beside the regenerator  
tank.  
Safety Valve  
- This valve will release (pop off) if boiler pressure exceeds 15 psi.  
Once a week, this valve should be tripped during operation to make  
sure it functions properly.  
Pressure Regulator  
- Reduces the steam pressure from the boiler to the steamer  
compartments to 6 psi. Twice a year, unscrew the large hex head  
plug located at the bottom of the regulator and remove and clean  
the strainer. Carefully reassemble.  
STEAMING  
Each steaming compartment is controlled by its own controls. When a compartment is not operating,  
the drain is open and the steam inlet valve from the boiler is closed. Food, properly portioned and in  
appropriate solid or perforated pans, is placed on rack supports (or wire shelves) in the steaming  
compartment. After closing and sealing the door, setting the timer and pulling out the operating handle,  
the steam inlet valve from the heat exchanger opens, allowing steam at a pressure of 6 psi to enter the  
compartment. Air from the sealed compartment exits through the vent until the temperature reaches  
180°F (82°C); then the vent closes, and the compartment can become pressurized. Steaming  
continues until the timer reaches “0” and the buzzer sounds. To silence the buzzer, push in the  
operating handle. Wait 1 minute for steam or hot water to drain away. Open the door and remove the  
cooked food.  
The cabinet (lower portion of steamer) contains the heat exchanger which has a steam coil in a  
pressurized tank. The steam coil is supplied with steam from an outside source which exchanges its  
heat and makes clean steam from fresh water fed into the tank. The supplied steam is kept separate  
from the newly created steam. Because of this separation, the outside steam source may be  
contaminated or toxic and yet does not come in contact with food. Only the clean steam created in the  
heat exchanger tank is sent to the compartments.  
PREHEAT COMPARTMENTS  
If the steamer has been standing idle and the compartments are cold, preheat before loading.  
– 9 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COOKING GUIDELINES  
The cooking guidelines in this manual are suggestions only. You should experiment with your food  
products to determine cooking times that will give you the best results. Variables which affect cooking  
time include size, weight, thickness of foods, temperature, density, previous condition of the foods  
(fresh, preblanched or frozen) and how thoroughly the food is to be cooked.  
To allow steam to circulate around the pans, food must be spread evenly and not piled too high. Best  
results are obtained after the compartments are allowed to preheat. When all compartments are to be  
loaded at the same time, it is best to allow the first compartment to reach 4 to 4.5 psi before starting the  
next compartment. When processing frozen vegetables, use half the suggested pan weights and allow  
sufficient time for cooking.  
WEIGHT/  
QUANTITY  
PER PAN MINUTES  
STEAM  
TIME  
PAN  
DEPTH  
PERFORATED  
OR SOLID  
PANS PER  
COMPARTMENT  
PRODUCT  
VEGETABLES (fresh)  
Beans, lima  
10 - 12  
13 - 15  
1 - 3  
4 - 6  
2.5"  
2.5"  
2.5"  
2.5"  
2.5"  
2.5"  
2.5"  
2.5"  
4"  
Perf  
Perf  
Perf  
Perf  
Perf  
Perf  
Perf  
Perf  
Solid  
Perf  
Solid  
5 lbs  
15 - 20  
20 - 25  
1 - 3  
4 - 6  
Beans, string or wax  
Broccoli, florets  
Broccoli, stalks  
Carrots, sliced  
6 lbs  
8 - 10  
10 - 12  
1 - 3  
4 - 6  
6 lbs  
10 - 15  
15 - 20  
1 - 3  
4 - 6  
6 lbs  
18 - 21  
21 - 25  
1 - 3  
4 - 6  
9 lbs  
9 - 10  
11 - 13  
1 - 3  
4 - 6  
Corn  
5 lbs  
6 - 7  
8 - 9  
1 - 3  
4 - 6  
Peas  
5 lbs  
20 - 25  
25 - 30  
1 - 3  
4 - 6  
Potatoes, chunked  
Rice, add 1 gallon of water  
Spinach, cut, cleaned  
10 lbs  
22 - 24  
25 - 27  
1 - 2  
3 - 4  
4lbs  
3 - 5  
4 - 6  
1 - 2  
3 - 4  
4"  
3 lbs  
4 - 5  
5 - 8  
1 - 3  
4 - 6  
Vegetables, canned  
OTHER FOODS  
Chicken  
2.5"  
7 lbs  
18 - 25  
25 - 30  
1 - 3  
4 - 6  
2.5"  
2.5"  
2.5"  
2.5"  
2.5"  
4"  
Perf  
Solid  
8 lbs  
6 - 7  
7 - 8  
1 - 3  
4 - 6  
Eggs, out-of-shell  
Eggs, in-shell  
4 doz  
2 - 3  
4 - 6  
1 - 3  
4 - 6  
Perf  
3 doz  
8 - 12  
10 - 15  
1 - 3  
4 - 6  
Fish, fillets  
Perf  
3 lbs  
35 - 40  
40 - 45  
1 - 3  
4 - 6  
Meatloaf  
Solid (for broth)  
Solid  
15 lbs  
20 - 22  
23 - 26  
1 - 2  
3 - 3  
Spaghetti, add 7 quarts of water  
Turkey  
3 lbs  
50 - 60  
60 - 75  
1 - 3  
4 - 6  
2.5"  
Perf  
10 - 12 lbs  
– 10 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING  
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW  
LOCKOUT / TAGOUT PROCEDURES.  
Do not apply food oils or petroleum lubricants to the door gasket.  
At the end of the day, turn the main power switch OFF (automatic blowdown drains the boiler tank).  
Allow compartments to cool. Remove pans and side racks and wash in a sink. Remove any food  
sediment from compartment bottoms. Wash compartment interior with mild detergent and warm water,  
rinse and wipe dry. Do not use steel wool on stainless steel surfaces. Replace side racks.  
Wash the gasket and sealing surface of the compartment door daily with mild detergent and warm  
water, rinse with clean water and wipe dry.  
Turn handwheel fully counterclockwise to retract the gasket plate and avoid pressure on the door  
gasket when the steamer is not in use.  
Wipe all solids away from the drain opening to prevent clogging. Remove, clean and replace the  
stainless steel strainer if food or dirt accumulates. If greasy foods have been cooked, operate the  
steamer to dissolve and drain away grease. Close door, seal compartment, set timer and, at frequent  
intervals, pull out and release the operating handle to blow steam through the drain valve.  
– 11 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
WARNING: THE STEAMER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING,  
CLEANING OR SERVICING THE STEAMER.  
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW  
LOCKOUT / TAGOUT PROCEDURES.  
DELIMING  
Refer to the water filter manual shipped in the box with your steamer.  
LUBRICATION  
Once each month, lubricate the thrust screw of each compartment door. To access the thrust screw,  
open compartment door and turn handwheel fully clockwise until gasket plate is fully extended. Grasp  
finger hooks and lift up to remove gasket plate assembly. Apply grease (order part 880786 from your  
Vulcan servicer) to the thrust screw while rotating the handwheel to assure complete coverage.  
Replace gasket plate assembly. Turn handwheel fully counterclockwise to retract gasket plate into  
door. Close door.  
DOOR GASKET  
If the door gasket becomes damaged from nicks or cuts and steam leakage results, contact your  
Vulcan-authorized servicer to have the gasket replaced.  
SERVICE  
Contact your local Vulcan-authorized service office for any repairs or adjustments needed on this  
equipment.  
FORM 30914 Rev. A (Jan. 2003)  
PRINTED IN U.S.A.  
– 12 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technicolor Thomson Stereo System DPL580HT User Manual
Thermador Cooktop CIT304GB User Manual
Toshiba Laptop A205 S4638 User Manual
Toshiba Projection Television 51H94 User Manual
Vermont Casting Range 2905 User Manual
Vita Mix Blender Advance and Portion Blending System User Manual
VTech Tablet vtech light up baby touch tablet User Manual
Wagner SprayTech Paint Sprayer GA 250AL User Manual
Weber Gas Grill 55767 User Manual
Weed Eater Tiller 152122 User Manual