Vivotek Network Card IP3111 IP3121 User Manual

NetworKam  
IP3111/IP3121  
User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Before You Use........................................................................................1  
Package Contents...................................................................................6  
Physical Description...............................................................................8  
How to Install .......................................................................................12  
Ethernet Environment.........................................................................13  
2
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Web  
FTP  
3
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Telnet  
4
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Package Contents  
NetworKam IP3111/IP3121  
Power adapter  
Null modem cable  
I/O terminal block connector  
6
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Wrench  
Installation and document CD  
Quick installation guide  
Warranty card  
7
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Physical Description  
Rear Panel  
Ethernet 10/100 socket  
Connect to Ethernet network with a UTP category 5 cable that cannot exceed 100 meters. Once the  
Ethernet cable is connected without error, NetworKam will utilize Ethernet interface regardless of modem  
connection.  
COM port  
This RS232 serial port can connect with a modem or included null modem cable to utilize dial-up  
network when Ethernet is not available. If NetworKam operates with Ethernet interface, administrators  
may use this port to control custom Pan-Tilt device.  
8
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
General I/O terminal block  
1
2
3
4
5
6
Å
Å
Å
Å
Å
Å
DI+  
DI-  
INPUT  
INPUT  
(Max. 50mA, 12VDC)  
SW_COMMON OUTPUT  
(short with NC at initial state)  
(Max. 1A, 24VDC or 0.5A, 125VAC)  
(inverting)  
SW_NOPEN  
RS485 B  
OUTPUT  
RS485 A  
(non-inverting)  
NetworKam provides a very flexible general I/O interface to combine with the user’s security devices  
such as sensors, alarms, lighting or door locks. The general I/O terminal block has six pins for device  
control. These pins can be divided into two categories based on their functions, including RS485 and  
digital inputs and outputs.  
If the device connected to COM has an RS485 interface, wire two control lines to pin 5 and pin 6. After  
switching to RS485 on the configuration page, the PT control commands will be directed through pin 5  
and pin 6. If the distance from the controlled device is too far to allow accurate function, an external  
power source may be used to pull high the RS485 signal.  
NetworKam provides one digital input and one relay switch. Pin 1 and pin 2 can be connected to external  
sensor and the state of voltage will be monitored according to the programmed scripts in configuration.  
The relay switch can be used to turn on or off external devices.  
9
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Status LEDs  
Each time NetworKam starts, it will perform a Power-On Self Test, abbreviated as POST hereafter, to  
examine every hardware module. As soon as the administrator plugs in the power adapter, both LEDs  
under the network LED will flash one by one until the POST is done. If any module fails, both LEDs will  
indicate to the users the error according to the pattern listed in Appendix A. If the result is good, both  
LEDs will turn off for a while and then follows the pattern below. Network interface depends on the  
peripherals including Ethernet UTP cable, modem or null modem cable. If the Ethernet cable between  
NetworKam and Ethernet hub is good, NetworKam will choose the Ethernet network. If Ethernet is  
unavailable but a operational modem is connected, the network interface will be PPP with modem. If  
either of the above is not the case, NetworKam will try the interface of PPP with null modem.  
Network Interface  
Ethernet  
Condition  
LED2 (Heartbeat)  
LED3 (Status)  
before installed  
after installed  
OFF  
flash  
flash  
flash  
OFF  
OFF  
Flash  
ON  
during camera control  
after POST  
PPP with modem  
PPP with null modem before connected  
after connected  
ON  
ON  
ON  
flash  
10  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Restore button  
There is a button hidden in the box for restoring the system factory default settings. When the system fails  
to install or operates abnormally, use the included assistant stick in the package and follow the following  
procedures to reset the system back to its original status.  
Poke the assistant stick into the hole to press down on the restore button. Restart the system by  
unplugging and re-plugging the power jack. While keeping the button pressed, the system will perform  
POST twice rather than the usual once, which can be observed from the flashing LEDs. After the system  
flashes the LEDs for the second time, withdraw the stick to release the button. The system will have  
restored factory default settings at that moment.  
Power adapter  
Connect the power jack of the included power adapter. Connecting the power adapter should be the last  
operation while physically installing NetworKam.  
Auto Iris Lens Connector  
If the auto iris lens is used, AES on rear panel must be turned OFF. And you also have to select VIDEO  
Drive or DC Drive lens by the switch.  
The pin assignment of the auto iris lens connector is as follows:  
VIDEO Drive DC Drive  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Power source Damp-  
Video signal  
Not used  
Damp+  
Driver+  
Ground, Shield Driver-  
11  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
How to Install  
To easily fit into various environments, NetworKam automatically detects the attached interfaces and  
configures itself to the best condition. Therefore users need not care how to select the network between  
Ethernet and modem, and whether the Ethernet speed is 10Mbps or 100 Mbps. The high performance  
built-in CCD and lens always give users delicate image quality.  
NetworKam supports Ethernet and modem interfaces according to the user's existing network. Ethernet  
can provide higher bandwidth to achieve the best performance while dial-up network with modem is more  
common in current Internet applications. Refer to the related installation section for your network  
environment. If both interfaces are available, Ethernet is recommended and will be chosen as the first  
priority if Ethernet cable and modem are concurrently attached. Managing to install in the other interface  
will automatically clear the previous network settings to start new installation.  
In the following content, "user" refers to those who can access NetworKam and "administrator" means the  
supervisor who has the root password to configure NetworKam in addition to general access.  
Administrators should carefully read this manual, especially during installation.  
12  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ethernet Environment  
Hardware installation  
Before installing multiple NetworKams at the well-chosen locations, the administrator should memorize  
the serial numbers on the packages respectively for future use.  
Cable connection  
Shut down all the peripheral devices prior to connection. Connect the supplied cables from NetworKam to  
related devices according to the following steps. Note that the power adaptor must be kept unplugged  
until other cables are firmly connected.  
13  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Power on  
Make sure all cables are correctly and firmly connected before turning on NetworKam. Turn on cameras,  
sensors, alarm devices, and then attach the power adaptor of NetworKam to the electric power socket*.  
After the POST (power-on self test) is complete and the result is successful, NetworKam is ready for  
software configuration as described in this manual. At this stage, network speed and video modulation  
type are automatically detected. If the detection of video modulation fails, administrators may change the  
setting on the configuration page. Refer to the configuration section for further information.  
Connect the power jack of the power adapter to NetworKam prior to plugging the utility end into the  
utility power socket. It will reduce accidental electric surge shock.  
14  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Software configuration  
Easy way with installer program  
In order to configure NetworKams remotely, administrators should keep the serial numbers of the new  
NetworKams for identification and initial passwords. After successfully mounting NetworKams in the  
proper position, run the Installer program on the appropriate PC to locate the newly installed  
NetworKams. NetworKams also support manual setup procedures to non-Windows based environments.  
The manual procedure is described next.  
After the POST is done, NetworKam will try to configure itself by detecting the network environment. If  
there is DHCP service over the network, the Installer program will catch the given information and  
display the serial number and given IP address for each NetworKam as following figure. If no DHCP  
service is available, a previous IP address will be displayed instead. In that case, it may be 0.0.0.0 for a  
brand new unit. When multiple units are mounted, there may be several entries shown in the window.  
Administrators may click on each entry with "Assigned" field labeled "No" to install sequentially.  
15  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
The IP address shown in "Current IP Address" field is for the administrator's reference. If the  
administrator wants to use another IP address, modify the IP text field below the list window.  
If the administrator wants to fix the IP address of the unit, check the option "Use this IP whenever system  
boots" to skip future installation procedures. Otherwise the unit will need installation whenever it is  
restarted.  
16  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
When IP and options are O.K., click on  
IP address is valid.  
. A message window will pop open to inform if the  
If the IP is not taken by another network device in the network, the Installer program will continue with  
the setup. Otherwise another message window will warn that the assigned IP conflicts. In this case,  
administrators should ask the network supervisor for a vacant IP address.  
17  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
After successful notification, administrators may keep the address information for user’s request.  
After clicking on  
on  
, the "Assigned" field will be labeled "Yes". Administrators may click directly  
to access the newly installed server in the default browser.  
18  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
While checking “Use this IP whenever system boots”, a dialog window may pop out to ask for “Server  
FTP Port” and “Root Password” because they are already changed to other than default settings. If the  
settings are lost, restore default settings and use installer to install again.  
Once installation is complete, administrators should follow the actions in the "First access to  
VisualServer" section for necessary checks and configurations. Experienced administrators may use the  
customized config.ini script file to perform a quick setup via FTP. Detailed procedure can be found on the  
section “One-shot fast configuration via FTP”.  
To allow users to connect to NetworKam through an easily memorized name, the administrators must first  
configure the name server in his network. Here is an example: When the administrator wants to set up  
NetworKam with a fixed IP address and let users connect to NetworKam by typing a name instead of IP  
address, the administrator may reserve the IP from DHCP service and assign it with name in the domain  
name service. During NetworKam installation, assign the ready IP address. After successful installation,  
users may access the NetworKam by the given name.  
19  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Manual way with existing programs  
For those environments such as MAC, Linux, Unix or other operating systems, whose installer is not yet  
available, some common network tools including ARP and PING can be used to install NetworKam.  
Make sure ARP and PING programs exist in your operating system.  
First, type arp –s “assigned IP address” “Ethernet address” to add an entity in the system’s name table.  
The Ethernet address is identical to the serial number of NetworKam and should be typed in the  
appropriate format like “uu-vv-ww-xx-yy-zz” or “uu:vv:ww:xx:yy:zz”, which depends on the operating  
system.  
Once a name entity is added, type ping "assigned IP address” to invite the new NetworKam. If it replies,  
that means NetworKam has accepted the assigned IP address and is ready for access. The first several  
ping requests may fail during the self-configuration period of NetworKam. Since the accurate grammar of  
ARP and PING depends on the operating system, refer to its related help manual.  
20  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
First access to NetworKam  
When connecting to NetworKam for the first time, administrators should check security and network  
settings on the configuration page. For complete protection from illegal usage, NetworKam provides two  
privileges and always needs user name and password before access. The standard level is the USER mode  
that consists of twenty user profiles. Each user is able to access NetworKam except for system  
configuration. The twenty user profiles are also maintained by the administrator. The highest level is  
ROOT mode that only opens to administrators for initial setup, system configuration, user administration  
and software upgrade. The user name of the administrator is internally assigned to “root”.  
When connecting to NetworKam, users will be requested for user name and password by an  
authentication message window. A root password, identical to the NetworKam's serial number, is needed  
for the initial access to a newly installed NetworKam. The administrator must change the root password  
immediately after the initial installation to ensure security. The new root password should be well  
memorized since there is no way to retrieve or recover it. After changing the password, the browser will  
display an authentication window again to ask for the new password.  
The other important part is network settings. The software configuration above makes NetworKam easily  
accessed through local networks. However administrators should review the network settings on the  
configuration page according to the existing service. The safe and easy way is to compare the network  
settings with another PC or workstation in the same network.  
The software installation in the previous section only set the host IP address and default subnet mask as  
255.255.255.0. Administrators should change the subnet mask if it differs from the one provided by server.  
Administrators should also fill in the default gateway, primary and secondary domain name servers if  
necessary.  
By default NetworKam will need administrator's installation every time it reboots. If the network settings  
are sure to work all the time, disable the install option if this IP address is already reserved for this  
NetworKam. Clearing this option will skip the installation procedure during the next power-up and use  
21  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
the previous settings. If the install option stays checked, NetworKam will perform the installation  
procedure every time the system boots up.  
Details about configurations are described in the "How to Use" section. Related figures are attached for  
easy reference.  
22  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Modem Environment  
Hardware installation  
Before installing NetworKam, the administrator should memorize the serial numbers on the packages  
respectively for the initial passwords.  
To use a dial-up network, the Ethernet socket should be left disconnected since Ethernet is the first  
priority among available interfaces. After powering up, NetworKam will detect if any external modem is  
connected to the modem port. Once a modem is detected, the heartbeat LED will flash periodically. If no  
modem responds, NetworKam will assume the included null modem cable is connected to perform  
system configuration. Then both lower LEDs will turn on until null modem connection is established.  
If users have setup a remote dialup server or subscribed to an ISP service, NetworKam can be configured  
to dial to the server upon special events. Otherwise it will wait permanently for the user’s call to establish  
a network connection to provide services.  
In the following content, dial-in connection denotes a passive NetworKam waiting for a phone call to  
establish a point-to-point connection. Dial-out connection denotes an active NetworKam to dial out to the  
other end of a dial-up server or any Internet service provider, abbreviated as ISP, to request a  
point-to-point connection.  
23  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Cable connection  
Shut down the peripheral devices prior to connection. Connect the supplied cables from NetworKam to  
the related devices according to following steps. Note that power adaptor must be kept unplugged until  
other cables are firmly connected. For the first access to NetworKam without Ethernet, administrators  
may use the included null modem cable to connect to COM for direct connection. It is also convenient for  
administrators to access NetworKam through the null modem cable directly without modem or Ethernet  
card. After necessary information is entered, a modem can be used to dial into the Internet.  
Power on  
Make sure all cables are correctly and firmly connected. Turn on cameras, sensors, alarm devices, and  
then finally attach power adaptor of NetworKam to the electric power outlet*. Since most automatic  
detections of hardware perform when the system starts, NetworKam should be turned on after all  
peripherals are turned on and ready.  
Connect the power jack of the power adapter to NetworKam prior to plugging the utility end into a  
utility power outlet. It will reduce accidental electric surge shock.  
24  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Software configuration  
For the first time, users should connect the included null modem cable between the COM port of  
NetworKam and any COM port of the PC for initial setup.  
Install a new modem  
Open the control panel and double click the modems icon.  
25  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Check "Don't detect my modem......" item and click on  
to install a new modem.  
From (Standard Modem Type) choose the Standard 33600 bps Modem and click on  
.
26  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Choose the serial port that the included null modem cable is attached to and click on  
modem is now ready for use.  
. The null  
If no Dial-Up adapter exists in the system, Windows will automatically prompt to install. Press  
continue.  
to  
27  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup a new connection  
After the 33600 bps modem is installed, open the dialup network folder in Windows to build a new  
connection.  
Select the device as the newly installed standard 33600 bps modem and click on  
.
28  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Just enter arbitrary digits as phone number and click on  
important.  
. The phone number used here is not  
After clicking on  
, this new connection will display in the Dial-up Networking folder and will  
be used for null modem connections.  
29  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Right-click on the newly setup connection icon for properties.  
In the first General page, clear "Use area code and Dialing Properties" option and click on  
.
30  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Select 115200 as the speed and click on  
.
On the second page, only check "Enable software compression" and "TCP/IP" while leaving others blank.  
Keep other settings as default values and click on  
connection.  
. Now the connection is ready for null modem  
31  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Double click the newly setup connection. A dialing information window will pop up. Enter “root” as user  
name and the serial number labeled on the bottom side of the box as the password and click on  
.
The user name and password are identical to what is used in web access and may be changed by  
administrators after successful installation.  
Notice that the letters in the serial number should be capital form. For example, type 'A' instead of 'a'.  
After some negotiation prompts, a connection status window will show the speed is 115200 bps.  
After connection is established successfully, go to the next section, "First access to NetworKam".  
If an error message indicates a hardware error while connecting for the first time, especially in a Windows  
2000 environment, try again to recovery the possible detection failure.  
32  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
First access to NetworKam  
Through direct connection by null modem cable administrators can open the default web browser and  
type in 200.1.1.1 as the address and press enter. Note that 200.1.1.1 will be the default IP address in a  
dial-in connection and 200.1.1.100 will be the given IP address for the user's PC by NetworKam. The user  
name and password are the same as what was entered during installation.  
After successful authentication, administrators should see the motion pictures in the main page. When  
using Microsoft Internet Explorer, administrators should allow a plug-in provided by NetworKam to  
install additionally. For best security, administrators must change the password on the system page of  
configuration immediately. After changing the password, the browser will display the authentication  
window again to ask for new password. Note that the new password will also be used in the next dialup.  
To make NetworKam successfully work in dial-in and dial-out modes, follow the procedures below for  
33  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
basic configurations. If people other than the administrator will be allowed to use NetworKam, the  
administrator should add these user profiles in the Security option. When NetworKam accepts dial-in  
connection and acts as a server, the user name and password used in dialing are the same as what was  
stored in the user database managed for web access. Any managed user can be authorized during PPP  
negotiation and access web pages. However only administrators can access the configuration page.  
There is more information needed for correct modem operation. Refer to the modem setting section in  
configuration for further settings. NetworKam will wait for someone to dial in. If the administrator has  
setup some conditions in the application, NetworKam will automatically dial out based on the  
administrator's configuration. Refer to the application section in configuration for special security  
applications. After everything is set and saved, turn off NetworKam and replace the null modem cable  
with modem for dial-up network. Since the null modem connection is used to configure NetworKam in  
advance for modem connection, administrators cannot connect again without restarting the system.  
If dial-out configuration is activated, NetworKam will dial out to send a system startup log to test and  
drop the call after the pre-configured period.  
34  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
How to Use  
NetworKam is a well-designed stand-alone network camera. With the built-in web server, authorized  
users may use web browser Internet Explorer to watch the video and hear the audio captured by  
NetworKam. The powerful video compression processes up to 30 frames per second and makes the scene  
in your browser as real-time display. The powerful audio compression processes the real-time audio and  
makes the synchronization of video and audio correctly. Also benefit from web interface, each function  
and each configuration has its specific URL that allows advanced users easily integrate them into existing  
software program.  
The preparation of the primary users to utilize NetworKam is quite simple since administrators have done  
the majority of the installation. Most administrators find the installation is easy in general environments  
because most settings are automatically configured. Open your web browser and connect to NetworKam  
just like a general web site and the audio and video will present on demand. Make sure the web address of  
the target NetworKam is accurate.  
35  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Authentication  
After opening the Web browser and typing in the URL of NetworKam, a dialogue window will pop up to  
request a username and password. For administrator’s initial usage of NetworKam, enter the username as  
“root” and the password as the serial number in capital letters. The serial number can be found on the  
labels under the body of NetworKam and the top side of the carton. The primary users will be allowed to  
enter as soon as the administrator finishes adding user profiles. Upon successful authentication, the main  
page will be displayed.  
In the figure below, the foreground is the login window and the background shows the message when  
authentication fails. The user may check the option to save the password for future convenience.  
36  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
If it is initial access to NetworKam in Windows, the web browser will ask to install a new plug-in that is  
provided by NetworKam. This plug-in has been registered for certificate and is used to display the  
motioned pictures in the browser. Users may click on  
to install the plug-in. If the web browser  
does not allow the user to install, check the Internet security option to lower security levels or contact  
network supervisors.  
37  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Primary user’s capability  
Main screen with camera view  
There is a logo image shown in the upper left corner. It can link to other web sites or resources depending  
on the settings in configuration. The assigned caption and system date/time will display in the banner  
above the image window. There might be some windows enclosed by red lines shown in the image as  
soon as motion is detected in the related windows. Click on the configuration link to the right of the  
image window to enter the configuration page.  
38  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Pan/Tilt positioning device control  
An external PT positioning device may connect to bear the NetworKam with motion capability. If the  
camera control option has been enabled, there are buttons under the image. It allows users to control the  
PT positioning device attached to NetworKam with pan/tilt direction. Additional five buttons below the  
image can be used to control cameras in ways other than pan and tilt. They should be pre-configured by  
administrators with reference to the instruction manual of the PT positioning devices.  
<url> http://<NetworKam>  
<NetworKam> is the domain name or pure IP address of NetworKam.  
39  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Client Setting  
If it is the first access to “Client Setting” page in Windows, the web browser will ask to install a new  
plug-in that is provided by NetworKam. This plug-in has been registered for certificate and is used to  
setting the client parameters in the browser. Users may click on  
to install the plug-in. If the web  
browser does not allow the user to install, check the Internet security option to lower security levels or  
contact network supervisors.  
There are two settings for the client side. One is “Media Option”. You can mute the audio by checking  
this option. The other is “Protocol Option”. You can choose the connection protocol between client and  
server by this option. There are three protocols - UDP, TCP and HTTP. When you choose UDP protocol,  
audio and video streams can be more real-time. But some packets may be lost and decoding error will  
happen. If you select TCP protocol, packet loss isn’t occurred and decoder will run normally. But the  
40  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
real-time issue is worse than UDP protocol. If your environment is behind the firewall and it opens HTTP  
port (80) only, you can select HTTP protocol only. In this mode, audio will not be sent and you just can  
see the video only. If you don’t know which protocol you should choose, select the UDP protocol and the  
client will try these protocols in this order, UDP TCP HTTP. After the client connects to the  
NetworKam successfully, “Protocol Option” will be set as the working protocol automatically.  
<NetworKam> is the domain name or original IP address of NetworKam.  
When using modem as the network connection, NetworKam will not send the audio automatically,  
and send video only because the low bandwidth environment doesn’t meet the requirement for both. In  
the Client setting page, protocol option will be set as Http protocol.  
41  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System configuration  
There are two methods provided for configuration. Web interface is quite easy and clear to use and FTP  
with script file is rapid for mass installation. System configuration can be accessed only by administrators.  
Administrators may type the URL below the figure to directly enter the configuration page. If  
administrators also want to set certain options through the URL, read the section on advanced usage for  
reference.  
<NetworKam> is the domain name or original IP address of NetworKam.  
42  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
System parameters  
To change the system name, type in the text box after "Host Name". This name will be displayed at the  
top of the main page. In the case that only the host name is changed, without adjusting date and time of  
NetworKam, click on "Keep current date and time".  
There are three ways to adjust system date and time. The easiest is to make NetworKam "sync with  
computer time". The second is to set the date and time manually. Notice the format in the related field  
while typing. The third is to make NetworKam automatically synchronize with timeservers over the  
Internet whenever NetworKam starts up. It may fail if the assigned NTP server cannot be reached or it is  
within a local network. Leaving the NTP server blank will let NetworKam connect to default timeservers.  
If some specific timeserver is assigned, type it in the text box. Domain name or IP address format is  
acceptable as long as DNS server is available. Do not forget to set the "Time Zone" offset for local  
settings. It only affects the hour in NTP method. Click on  
43  
to validate changes.  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User group administration  
To change the administrator’s password, type the new password in both text boxes identically. What is  
typed will be displayed as asterisks for security purposes. After pressing  
administrators for the new password for access.  
, the web browser will ask  
To add a new user, type the new user's name and password and press  
to insert the entry. There are a  
total of twenty user accounts. Since only administrators can change a user's password, confirmation for a  
user's password is not necessary.  
To delete a user, pull down the user list to find the user name to be deleted and press  
.
44  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Network settings  
Any change made to this page will make the system restart to validate. Make sure every field is correctly  
typed before clicking on  
.
To eliminate incautious mistakes during installation, NetworKam will stay in installation mode whenever  
it starts unless "Reset network at next boot" is disabled. This option can also be disabled using the  
Installer program. Once the option is disabled, NetworKam will skip installation at the next boot and the  
Installer program will not find the installed units. That implies that NetworKam cannot be accessed if no  
one remembers the IP address, except by restoring factory default settings. However, with this option  
disabled NetworKam can automatically operate normally after restarting in case of losing power. This  
option is ignored in the PPP connection.  
Administrators may modify the network settings to fit into existing networks. Some broadband service  
45  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
subnet mask may differ from the default value 255.255.255.0 and service providers may assign some  
specific network settings. Administrators should change the configuration according to what is given by  
the service provider. The configuration may include "IP address", "Subnet Mask", "Default Router",  
"Primary DNS" and "Secondary DNS". After changing network settings, be sure to leave "Reset  
network at next boot" blank to skip installation when the system restarts. Otherwise the settings will be  
erased.  
NetworKam not only plays the role of server, it will also actively connect to servers outside to send out  
messages or snapshots. When NetworKam starts, it will send out a system log to notify administrators.  
Even in modem application, NetworKam will send out a connection log whenever it dials out to an ISP or  
dialup server outside. If the administrator has setup some applications in either event mode or sequential  
mode, NetworKam will send out snapshots once conditions are met. There are two methods to send files,  
including e-mail and FTP. To ensure NetworKam sends out files correctly, the administrator should set  
valid "SMTP (mail) Server" and "Recipient Email Address" as well as "Primary FTP Server",  
"Primary FTP Server", "Primary FTP User Name" and "Primary FTP Password". “Return email  
address” is whom the mail will return when the SMTP server rejects upon any failure. Some ISP may  
reject the mail if the address is invalid. "Primary FTP remote folder" is the relative sub-folder in the  
remote FTP server.  
In both methods, a "Secondary" server can be provided for backup connection. However the primary  
server information should be entered first. If the primary server is not set, the related FTP or email will be  
deactivated. Note that it may take time to connect to the secondary server after the first one fails and it  
may affect some applications when conditions happen too often.  
For security or network integration, administrators also can hide the server from the general HTTP port by  
changing "HTTP Port" to other than 80 and known port numbers such as 21 and 23. These ports of  
Control Channel Port”, “Audio Channel Port” and “Video Channel Port” which are used in media  
transmission can also be changed. Administrators should have enough acknowledge before changing the  
default port.  
If the NetworKam works in variation or low bandwidth (comparing with video bandwidth) environment,  
46  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
the client side will receive the poor quality of media. For improving this situation, you can check the  
Improve audio quality in low bandwidth environment” item. It can make the audio quality better, but  
the media delay is longer and real-time issue is bad. If the network performance is worst, please select  
the ”UDP protocol“ as the communication protocol in “client setting”  
After everything is set, click on  
. A warning message will pop up. Click on  
to confirm.  
NetworKam will automatically restart. If "Reset network at next boot" is kept checked, run the installer  
procedure again. Otherwise NetworKam will restart automatically.  
Administrators should notice that the IP address, subnet mask, default router and DNS servers will be  
cleared when the network interface is switched to the other. Refer to the related section of Ethernet or  
modem for software installation.  
47  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Video codec parameters  
Options on this page will affect the image on the main page seen by users. "Text on Video" will be  
displayed above the video window with a timestamp. The timestamp is captured from date and time of  
NetworKam that is maintained by a built-in real-time clock.  
"Size" option allows users to adjust the image size taking into consideration bandwidth and visual effect.  
Three options are available including half, half×2 and normal. Half×2 consumes the same bandwidth as  
half but is the same size as normal. Of course the image is not as good as normal. Half×2 is especially  
suited to low bandwidth environments like a dial-up network.  
48  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IP3111/IP3121 uses MPEG4 codec compression for best streaming solution. The compressed video data  
is far less than JPEG in normal cases but it still depends on the level of difference between every two  
sequential images. There are three dependent parameters provided for adjustment. "Maximum Frame  
Rate" limits the maximal refresh frame rate that can be combined with the "Video Quality Control" to  
optimize the bandwidth utilization and video quality. If users want to fix the bandwidth utilization  
regardless of the video quality, choose "Fix Bit Rate" and select the desired bandwidth. The video quality  
may be poor in order to send maximal frames within the limited bandwidth when images change  
drastically. Consequently to ensure the video quantization rate regardless of the bandwidth, it will utilize  
more bandwidth to send the maximal frames when images change drastically.  
The option "Enable Motion Detection" will control the event of motion detection on the application page.  
If this option is enabled, the preset windows framed by red lines will appear in the video window even if  
no option is checked on the application page. If this option is disabled, then any settings related to motion  
detection will have no effect. Motion detection will increase system load. Enter the motion detection  
option page for advanced configuration.  
To adjust video from external cameras, use "Flip" to map the video vertically and "Mirror" to map the  
video horizontally.  
49  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To adjust image settings for best visual quality, press  
and a motion picture window will  
pop up for your reference. There are four fields including "Brightness", "Contrast", "Hue" and  
"Saturation" for video compensation. . Each field has eleven levels ranged from -5 to +5. The user may  
press  
to fine-tune the image. When the image is O.K., press  
to memorize the image  
settings or  
to recall the original settings. If parameters are changed without saving, they will be  
used until the next system startup.  
50  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Motion detection  
Please note that the option "Enable Motion Detection" on the video page must be enabled to make  
detection effective.  
NetworKam allows administrators to define at most three detection windows to cover different areas. To  
monitor a specific area, click  
to add a new window. The typed text in "Window Name" will show  
at the top of the window. Use the mouse to drag the border to the desired size or title bar for location.  
Higher sensitivity and small percentage will make motion easier detected easier and vice versa. After  
clicking  
, a graphic bar will go up or down depending on the image variation. A green bar means the  
image variation is under monitoring level and a red bar means the image variation is over monitoring  
level.  
51  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
The following figure shows the screen when  
by red squares.  
is clicked. The monitoring windows will be marked  
52  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Camera positioning device configuration  
Since NetworKam can be used in either PPP network or Ethernet network, the single serial port can  
control either external serial port devices like camera positioning devices or a data modem. While in PPP  
interface, go to Modem page for modem configuration. Options on this page will be ignored.  
To control the external PT positioning device, “Enable camera control” must be checked and the control  
panel or buttons will thus display on the main page. NetworKam supports RS232 and RS485 interface to  
control external serial port devices. Refer to the hardware description to connect an RS485 device. The  
Port Settings” and “Control Settings” must be configured according to the instruction manual of the  
external serial port device. The "Baud rate (bps)" of the serial port is up to 115200 bps.  
The commands in "Control settings" should be edited in ASCII format. NetworKam will interpret the  
ASCII format command to binary string. For instance, “012000ABCD” will be sent out of the COM port  
53  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
as five hexadecimal bytes of 01, 20, 00, AB and CD. If the command string is composed of two or more  
commands, a comma ‘,’ should be inserted to separate each command. Each comma represents 200  
milliseconds. For instance, a command to pan left may be “01000305” and a command to stop panning  
may be “01000300”. The user may edit the applicable command as “01000305,01000300” in the “Move  
Left” field. This means the camera will pan left for 200 milliseconds. The maximal length of a command  
string is 60 which is equivalent to 30 hexadecimal bytes. When everything is set, click on  
the commands and click on to close the command setting window.  
to save  
NetworKam provides five more custom commands other than general pan, tilt functions. Administrators  
can click on and refer to the instruction manual of the attached device to setup  
frequently used functions. The "Command" should be entered in ASCII format alike the pan, tilt  
commands. "Display string" is for those texts on command buttons and should be less than 8 characters.  
To enter more commands or commands other than pan and tilt, a flexible URL is provided for customized  
interface. See the “Clear data path for proprietary commands” section in Advanced functions for details.  
54  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Modem and dialup settings  
In PPP interface, a modem option will work instead of camera control. Configurations include modem  
initialization and outside dial-up server. If the users will setup with external sensors and alarms for  
property security, dial-out is needed to send some snapshot-attached e-mails when the preset conditions  
are triggered. In such applications, also remember to choose Network option to enter mail server address  
and recipient's e-mail address. If "Dialout allowed" is not checked, NetworKam will not send out any  
snapshots when events occur and the settings except for "Initial modem command" in this page will  
have no effect. The system will preset the attached modem to eliminate echo and mute line sound. To  
initialize the modem with further commands, type into the edit box. The prefix "AT" should be included.  
Administrators should choose an appropriate "Dial Method" according to the local POTS environment.  
An incorrect dialing prefix may cause NetworKam to fail when dialing out. "Redial attempts" means  
how many times NetworKam should try to connect to each ISP. Setting the value in "Disconnect after  
55  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
minutes" will force NetworKam to drop the connection when there is no activity on the connection for  
the specific period. The range of this period is from 1 to 240 minutes, with 0 indicating a continuous  
connection. Administrators may let NetworKam keep the connection for a while to allow connections  
from outside. The IP address given by the ISP can be taken from the connection log that is mailed or  
uploaded when dial-up connection is successful. Setting the value to zero will make NetworKam always  
keep the connection.  
Based on the settings of DI/DO in the application, the system will send mail or upload via FTP with  
image attachment upon the event occurring. In that case NetworKam will need a network connection and  
automatically dial out to the pre-configured server outside. When a connection is successfully established,  
NetworKam will send out a connection log to notify given network settings. For those installations that  
may switch the network interface between Ethernet and PPP, administrators should notice that the settings  
of FTP or SMTP servers might be different from what is in an Ethernet environment. If the network  
interface is changed, administrators may need to configure them in advance.  
NetworKam will try the second ISP as a backup when the first ISP fails and exceeds the redial attempts.  
"ISP phone number" should be the complete phone number including country code and area code if  
necessary. "Login username" and "Login password" are used to pass the PPP negotiation requested by  
the ISP server. Note that the pair of login name and password is dependent on the ISP and is different  
from what is used in the authentication process in web access.  
When using modem as the network connection, NetworKam will mute the audio automatically, and  
send video only because the low bandwidth environment doesn’t meet the requirement for both. In the  
Client setting page, protocol option will be set as Http protocol.  
56  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Application  
Administrators can use combinations of options on the application page to perform many useful security  
applications. The sending method is selected at the bottom of the page. Both e-mail and FTP use the  
network settings on the network page. To use FTP to upload snapshots, a timestamp file name can help  
administrators identify the event. If "FTP put snapshot with date and time suffix" is disabled, the  
up-to-date snapshot will overwrite the file.  
There are two application methods to upload snapshots. "Sequential operation" will send out snapshots  
continuously over a configured period. This mode can be used to integrate with another web server to  
serve overloaded requests. If the date and time suffix option is disabled, NetworKam can use FTP to  
upload and overwrite snapshot files periodically. The remote folder of snapshot files for FTP can be  
configured on the network page. The snapshot period is between "Snapshot begin" and "Snapshot end"  
and it will repeat everyday. The snapshot interval is set in "Snapshot every seconds".  
57  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
The other "Event operation" can be used to combine motion detection with devices attached to digital  
input, to drive devices attached to digital output, or send out snapshots for evidence. It helps users  
establish an easy security system. Administrators may choose any combination of conditions to form  
special applications according to their personal needs. NetworKam will continuously monitor the channel  
and digital input every half second. Once the user-defined conditions are matched, NetworKams will  
capture three stages of events and react based on the "Trigger action" settings. The post-event snapshot  
can be configured to be delayed after events happen according to the setting in "Take snapshot at  
seconds after event". The three stages of snapshots will be VPRE.JPG, VTRG.JPG and VPOS.JPG. Since  
the same event may exist for a while, administrators can set delay time in "Delay seconds before  
detecting next event" to reduce multiple triggers by the same event.  
There are two kinds of "Trigger condition". For digital input there are four options provided to combine  
with the user's device. Rising and falling will make events happen once. For motion detection, there are  
window names shown below as choices. Refer to the previous section for configuring motion detection.  
Note that larger object size and lower sensitivity will make it more difficult for NetworKam to detect  
varied images. Once the "Trigger condition" is matched, NetworKam will drive the digital output device  
and/or upload snapshots based on the "Trigger action" settings. The application settings should be  
carefully examined to operate accurately. If administrators are not sure of the digital output status before  
configuring applications, "Reset output" can be used to return the digital output to the default “Normal  
Close” state.  
58  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Homepage layout settings  
Administrators may give NetworKam a different presence of homepage. The "logo graph" for the system  
logo in the upper-left corner can be hidden; or the default image from the system memory can be used; or  
an external resource can be used by assigning a URL. "background graph" is similar. Default images  
from system memory are quick to get but limited by memory size. Images from external resources can be  
larger and more beautiful but will need more time to load. If the background is skipped, the background  
color will fill the browser window. Administrators also can give the system logo a "logo link" to refer to  
another web site. The "font color" and "background color" can be chosen from sixteen colors to achieve  
the best visual effect.  
See "Customizing homepage images" section in "Advanced functions" for how to replace images.  
59  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
One-shot fast configuration via FTP  
For quick setup of NetworKam, the administrator can utilize the default CONFIG.INI that may be  
downloaded from the FTP daemon of NetworKam. To log into the FTP daemon, enter “root” as the user  
name and the same password used when connecting to the Web server. The serial number of NetworKam  
is the password for the initial access.  
Then administrators only need to modify necessary fields and then upload the file to NetworKam with the  
file name “CONFIG.INI”. To reduce error in interpretation, it is recommended that the downloaded  
template CONFIG.INI be modified using the options following each item in the sample below. The file  
will include seven categories: [SYSTEM], [NETWORK], [VIDEO], [SERIAL], [ALERT],and  
[LAYOUT]. The category name in brackets should be in upper case. The item name in angle braces  
should be in lower case. Some items related to disable/enable should use the keywords “YES”/“NO”. The  
number zero entry in <user name> and <user password> is for the administrator, i.e. “root”.  
Since the password when logging into FTP is not encrypted, it is recommended to use the Web instead of  
FTP to configure the system afterwards. If some parameters other than the network or camera drivers are  
changed, administrators can set <reset system> to NO to avoid resetting the system. It will automatically  
return to YES during the next downloading of CONFIG.INI.  
A sample CONFIG.INI is attached below. The italic text following each line describes the format of the  
field and the bold italic characters are the possible values of each field.  
******* sample file **********  
NetworKam Initial Configuration File  
[SYSTEM]  
<reset system>  
YES  
Reset system after reading CONFIG.INI or NO  
<host name>  
NetworKam  
<serial number>  
String shorter than 40 characters  
60  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
0002D1000001  
Read only string  
<software version>  
IP31x1-VVTK-0100  
Read only string  
<current date>  
2002/04/08  
year/month/date. Read only string  
hour/minute/second. Read only string  
From 12 to -12  
<current time>  
07:00:00  
<time zone>  
0
<user name>  
(0) root  
(1)  
Read only string  
String shorter than 15 characters  
The followings are as same as above  
(2)  
(3)  
(4)  
(5)  
(6)  
(7)  
(8)  
(9)  
(10)  
(11)  
(12)  
(13)  
(14)  
(15)  
(16)  
(17)  
(18)  
(19)  
(20)  
61  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
<user password>  
(0) 0002D1000001  
Initial value is as same as serial number  
String shorter than 15 characters  
(1)  
(2)  
The followings are as same as above  
(3)  
(4)  
(5)  
(6)  
(7)  
(8)  
(9)  
(10)  
(11)  
(12)  
(13)  
(14)  
(15)  
(16)  
(17)  
(18)  
(19)  
(20)  
[LAYOUT]  
<font color>  
1
color index: 0 for black, 1 for white, 2 for green,  
3 for maroon, 4 for olive, 5 for navy, 6 for purple,  
7 for gray, 8 for yellow, 9 for lime, 10 for aqua,  
11 for fuchsia, 12 for silver, 13 for red, 14 for blue,  
15 for teal  
<background color>  
0
62  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
<logo type>  
1
0 for blank, 1 for default image or 2 for loading from URL  
0 for blank, 1 for default image or 2 for loading from URL  
link to external resource when logo type is 2, no longer than 80  
link when background type is 2, no longer than 80  
<background type>  
1
<logo source>  
http://  
<background source>  
http://  
<logo link>  
http://  
providing external link when clicking on logo, no longer than 80  
<com speedlink name>  
(0)Command1  
(1)Command2  
(2)Command3  
(3)Command4  
(4)Command5  
no longer than 8 characters(some language will use double bytes)  
no longer than 8 characters(some language will use double bytes)  
no longer than 8 characters(some language will use double bytes)  
no longer than 8 characters(some language will use double bytes)  
no longer than 8 characters(some language will use double bytes)  
[NETWORK]  
<install enabled>  
YES  
or NO  
<ppp enabled>  
YES  
obsolete  
<ethernet address>  
00-02-D1-00-00-01  
<host ip>  
Read only string  
Standard IP format  
Standard IP format  
Standard IP format  
192.168.0.201  
<subnet mask>  
255.255.255.0  
<gateway ip>  
192.168.0.254  
63  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
<primary name server>  
192.168.0.1  
Standard IP format  
<secondary name server>  
168.95.1.1  
Standard IP format  
<ntp enabled>  
YES  
or NO  
<network timing server>  
ntp-cup.external.hp.com  
<smtp mail server>  
Standard IP format or string shorter than 40 characters  
Standard IP format or string shorter than 40 characters  
String shorter than 80 characters  
<mail recipient address>  
<mail return address>  
<backup smtp mail server>  
<backup mail recipient address>  
<ftp server>  
String shorter than 80 characters  
Standard IP format or string shorter than 40 characters  
String shorter than 80 characters  
Standard IP format or string shorter than 40 characters  
String shorter than 15 characters  
<ftp username>  
<ftp password>  
String shorter than 15 characters  
<ftp init path>  
String shorter than 40 characters  
<backup ftp server>  
<backup ftp username>  
Standard IP format or string shorter than 40 characters  
String shorter than 15 characters  
64  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
<backup ftp password>  
<backup ftp init path>  
String shorter than 15 characters  
String shorter than 40 characters  
Integer less than 1024  
<http server port>  
80  
<control channel port>  
5001  
Integer less than 65535  
<control channel port>  
5002  
Integer less than 65535  
<control channel port>  
5003  
Integer less than 65535  
[VIDEO]  
<caption text>  
String shorter than 15 characters  
12, 10, 8, 6, 4 representing Medium, Standard, Good, Detailed, Excellent  
among 5 and -5  
<video quality>  
8
<brightness>  
0
<contrast>  
0
among 5 and -5  
<hue>  
0
among 5 and -5  
<saturation>  
0
among 5 and -5  
<rate control>  
YES  
YES for fix bit rate, NO for fix quality  
1200k, 1000k, 768k, 512k, 384k, 256k, 128k, 64k  
<bit rate>  
384k  
<frame rate>  
65  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
30  
1, 2, 3, 5, 10, 15, 20, 25, 30 (30 for NTSC only)  
<video size>  
3
1, 2, 3 representing half, halfx2, normal  
<motion detect enabled>  
NO  
<flip>  
NO  
<mirror>  
NO  
[SERIAL]  
<auto detect camera>  
YES  
or NO  
<data bits>  
8
<stop bits>  
1
<parity bits>  
0
<baud rate>  
9600  
<enable camera control>  
1
<uart mode>  
RS232  
or RS485  
<other control commands>  
(0)  
(1)  
(2)  
(3)  
(4)  
String shorter than 80 characters  
String shorter than 80 characters  
String shorter than 80 characters  
String shorter than 80 characters  
String shorter than 80 characters  
66  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
<PT control commands>  
UP  
String shorter than 80 characters  
String shorter than 80 characters  
String shorter than 80 characters  
String shorter than 80 characters  
String shorter than 80 characters  
DOWN  
LEFT  
RIGHT  
HOME  
[ALERT]  
<application mode>  
0
for none, 1 for sequential mode, 8 for event mode, 9 for both  
<upload method>  
0
0 for FTP, 1 for email  
<file with time suffix>  
YES  
or NO  
<seconds to snapshot after event>  
0
<seconds to snapshot periodically>  
0
<time to start snapshot>  
00:00:00  
24 hours format  
24 hours format  
<time to stop snapshot>  
00:00:00  
<seconds delay before next event>  
3
67  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advanced functions  
Web  
Viewing system log  
Click the button on the configuration page to view the system log file. The content of the file reveals  
useful information about configuration and connection after the system boots up.  
Viewing system parameters  
Click the button on the configuration page to quickly view the whole system parameter set. The content is  
the same as CONFIG.INI.  
Restore factory default settings  
Click the button on the configuration page to restore the factory default settings. This means any changes  
made before will be lost and the system will be reset to the initial status when shipped from the factory.  
After confirmation, the system will restart and require the installer program to setup the network.  
68  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
FTP  
NetworKam not only has web service for easy access but also has a built-in FTP service to make system  
integrators easy to use. According to settings on the application page, NetworKam can sequentially send  
updated snapshots over a specific period to an external server with choices of overwriting and time suffix.  
For security staff, NetworKam can directly send snapshots to an external server as evidence according to  
event settings. Through NetworKam’s FTP daemon, administrators can quickly update configurations and  
maintenance.  
Those files with GIF extensions which are used for a homepage layout and can be read and overwritten.  
They also can be downloaded by managed users. Other files will be explained below.  
Uploading snapshots periodically to an external FTP server  
In sequential mode, NetworKam will send out snapshots according to interval and period settings. If  
snapshot files are intended for quick updates, it is better to skip date and time suffix. The file name will  
then be video.jpg. If the snapshots are used for occasional monitoring, suffix with date and time can help  
administrators classify them easily.  
Customizing homepage images  
There is a small icon before each link that can be changed by administrators. Administrators may change  
the look of the logo, background and image buttons by him or her self. There are three types of logos and  
backgrounds, blank, default and other URL. The default method will use the image stored in the Flash  
memory. Administrators may change the default logo, background image and button images by uploading  
customized ones. The followings are the referenced file names and size limitations.  
Object  
File name  
Maximal size  
Logo  
logo.gif  
Logo and background share 8000  
bytes  
Background  
Link icon  
back.gif  
Logo and background share 8000  
bytes  
btn_text.gif  
2000 bytes  
69  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Viewing system log  
Download SYSTEM.LOG and open it with any text viewer. The content of the file reveals useful  
information about configuration and connections after the system boots up. It helps administrators to  
easily find out who and how NetworKam was accessed since all network access to NetworKam is  
recorded with timestamp. The system log will scroll to keep the newest messages as eliminate old ones.  
Uploading the configuration file  
To update each NetworKam’s configuration at once, upload the accurately formatted batch file to  
CONFIG.INI. It is recommended to keep the original format, but changing values. Refer to the section in  
configuration for details and optional values as well. After successfully receiving and verifying the file,  
NetworKam will self-update the configuration and restart automatically. Refer to the previous section for  
further information.  
Software revision upgrade  
NetworKam is able to keep the most up-to-date software. Customers are allowed to download the updated  
binary codes upon receiving additional license from Vivotek and consequently upload it to NetworKam  
via FTP. This function is open to administrators only. The updated system code may be in compressed  
format and have name coded with version. Frequently check our web site for the latest version. To  
upgrade the system code, follow the procedures below.  
1. Decompress the compressed file in a local folder. A file named FLASH.BIN should appear.  
2. Use the FTP program and change the working directory to the local folder where FLASH.BIN exists.  
3. Connect to NetworKam with user name as “root” and password.  
4. Use the PUT command to upload FLASH.BIN to NetworKam. The file size is near 1.5 mega bytes. It  
will take approximately 2 seconds in a local network, 2 minutes by null modem connection or 6 minutes  
by modem, but still subject to user's network.  
5. After upload is complete, close the connection.  
6. If the received FLASH.BIN is checked without error, NetworKam will update the software in Flash  
memory and restart automatically. When NetworKam starts writing firmware, both status LED indicators  
will stay on until system restarts. It takes about 30 to 40 seconds. User should keep the power stable  
during the update process. After the system restarts, NetworKam may need installation depending on  
whether the “Reset network at next boot” option is enabled or not. After NetworKam boots up, reload the  
70  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
web page in the browser.  
If power fails during the software upgrade, the program in the memory of NetworKam may be  
destroyed permanently. If NetworKam cannot restart properly, ask the dealer for technical service.  
71  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Telnet  
NetworKam has a Telnet daemon for administrators to access some seldom used functions. Using any  
general terminal program to connect to NetworKam will prompt the user for a password. Username is not  
requested here since only administrators can access the Telnet daemon. The password is as same as that  
used for web access. After logging in, type "help" for the command list. If "debug" or "dinote" is not  
executed, Telnet will disconnect automatically after being idle for 1 minute.  
System core debugging  
General activities are recorded into SYSTEM.LOG continuously, but information about abnormal status  
is not. To look deep into the core debugging information, administrators may type the “debug” command.  
This will cause NetworKam to start dumping the detailed debugging information while the system is  
running. This is useful to examine if any error has occurred when the system operates abnormally. The  
stored information will be cleared automatically after the dump. NetworKam will continue to dump new  
messages unless the connection is broken. If Telnet is not connected, any messages will be stored until  
administrators re-login.  
Monitor changed status of digital inputs  
Typing "dinote" will make NetworKam send the current status of digital input. After that NetworKam will  
continuously monitor DI status and send messages only when the state has changed. For example, after  
typing "dinote" the terminal will display  
DI=L  
DI=L  
and if DI changes to H, terminal will display only  
DI=H  
Stop information dumping  
Typing "stop" will cease dumping debug information and digital input status.  
Query status of digital inputs  
Typing "diquery" will display the status of digital input once.  
72  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Set digital outputs  
To set digital output to connect NO with COMMON, type "DO=L".  
To set digital output to connect NC with COMMON, type "DO=H".  
Erase snapshots stored in Flash memory  
Typing "erase image" will clear all snapshots saved in Flash.memory.  
Erase logo and graphic buttons  
Typing "erase graph" will clear all images used on the homepage. If no new images are uploaded, the  
system will switch to text mode and use default images instead.  
Skip installation during the next boot  
Typing "lock" will inform NetworKam to fix current network settings. It need not wait for installation  
during the next boot.  
Reset network for new settings  
Typing "unlock" will make NetworKam give up current settings and wait for installation.  
Restore factory default settings  
Typing "clear" will make NetworKam restore factory settings but not restart. To validate new settings,  
type "reset" to make the system restart.  
Reset system  
Typing "reset" will make NetworKam perform a software reset.  
73  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
URL commands of NetworKam  
For some customers who already have their own web site or web control application, NetworKam can be  
easily integrated through convenient URLs. This section lists the commands in URL format  
corresponding to the basic functions of NetworKam. Some RFC standards related to HTML may be a  
good reference for implementation of the customized homepages.  
Capture update Snapshot of JPEG image  
/cgi-bin/video.jpg  
Move motorized device in PT direction  
<direction>:  
up, left, right, down, home  
<command>:  
1, 2, 3, 4, 5  
/cgi-bin/camctrl.cgi?move=<direction>&cust=<command>  
Query status of digital inputs  
/setup/getdi.cgi  
NetworKam will return status of digital input.  
Drive digital outputs  
/setup/setdo.cgi?do=<state>  
, where state is H, L. H means NC connected with COMMON and L means NO connected with  
COMMON.  
192.168.0.201, to set digital output to connect to NC with COMMON.  
Clear data mode serial port driver  
This URL applies to the attached serial port device including supported PTZ cameras or non-supported  
custom cameras. Note the serial port settings of custom cameras must be correctly defined in advance.  
74  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Send command to device attached to COM  
/cgi-bin/senddata.cgi?data=123456,ABCDEF&flush=yes&wait=1000&read=6  
This hyperlink will inform NetworKam to send out binary format commands to the COM with “0x12,  
0x34, 0x56” followed by “0xAB, 0xCD, 0xEF”. Each comma separates the commands by 200  
milliseconds. “flush=yes” means the receive data buffer of COM port must be cleared before read. Then  
read 6 bytes after waiting for 1000 milliseconds. The read data can be up to 128 bytes and will return as  
ASCII coded hexadecimal value, e.g., 0x41, 0x42, 0x43 read from COM port will show in returned  
homepage as 414243 instead of ABC.  
Restore factory default settings  
/setup/restore.cgi  
NetworKam will automatically restart after restoring factory default configurations.  
Restart system  
/setup/reset.cgi  
Restart NetworKam without warning.  
75  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Page URL  
The configuration page has a frame layout including an option list frame and an option page frame.  
Referenced URLs, except for the configuration page, direct users to the option page frame only. Some  
pages, like image quality setting and preset setting, are opened in new windows for preview.  
These URLs can be accessed only by administrators.  
Homepage name  
Client setting page  
Referenced URL  
/client.html  
configuration page  
system option  
/setup/config.html  
/setup/system.html  
/setup/security.html  
/setup/network.html  
/setup/video.html  
/setup/image.html  
/setup/camera.html  
/setup/modem.html  
/setup/command.html  
/setup/custom.html  
/setup/app.html  
security option  
network option  
video option  
image quality option  
camera control  
modem  
custom command setting  
custom camera setting  
application option  
homepage layout option  
system log  
/setup/layout.html  
/setup/logfile.html  
/setup/parafile.html  
/setup/factory.html  
system parameters  
set factory default  
76  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
System resource URL  
There are some images used on the homepage when the homepage layout is in image mode.  
Administrators may use the following links to show the images saved in NetworKam on another page. To  
change the images referenced by the URL, refer to the homepage layout section in configuration.  
Resource name  
Referenced URL  
system logo image  
background image  
/pic/logo.gif  
/pic/back.gif  
/pic/btn_text.gif  
icon image for link indicator  
General format of command URL  
Every configuration can be set through URL with POST method by administrators only.  
<general format>  
URL[?[name=value][&name=value]……]  
<method>  
POST  
<authorized user>  
root  
System configuration URL  
URL:  
NAME  
host  
/setup/system.cgi  
VALUE  
DESCRIPTION  
<text string shorter than 15 characters> system name  
method  
keep  
keep date and time unchanged  
auto  
use NTP server to synchronize  
directly adjust date and time  
year, month and date separated by slash  
hour, minute and second separated by colon  
NTP server  
manu  
date  
time  
ntp  
<yyyy/mm/dd>  
<hh:mm:ss>  
<domain name or IP address>  
-12 ~ 12  
zone  
time zone, 8 means GMT +8:00  
77  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Security configuration URL  
URL:  
/setup/security.cgi  
NAME  
rootpass  
VALUE  
DESCRIPTION  
<text string shorter than 15 characters> change root password  
username <text string shorter than 15 characters> add new user  
userpass  
deluser  
<text string shorter than 15 characters> new user's password  
<text string shorter than 15 characters> existing user name  
Network configuration URL  
URL:  
NAME  
reset  
/setup/network.cgi  
VALUE  
DESCRIPTION  
YES  
enable installation at next boot  
disable installation at next boot  
NetworKam's IP address  
subnet mask  
NO  
ip  
<IP address>  
<IP address>  
<IP address>  
subnet  
router  
domain  
dns1  
default gateway  
<text string shorter than 40 characters> domain name of NetworKam  
<IP address>  
primary DNS server  
secondary DNS server  
primary SMTP server  
dns2  
<IP address>  
smtp1  
mailto1  
smtp2  
mailto2  
return  
http  
<domain name or IP address>  
<text string shorter than 80 characters> mail recipient address  
<domain name or IP address> secondary SMTP server  
<text string shorter than 80 characters> mail recipient address  
<text string shorter than 80 characters> return address  
<number less than 65535>  
HTTP port  
controlport <number less than 65535>  
videoport <number less than 65535>  
audioport <number less than 65535>  
lowband Yes  
Control Channel port  
Video Channel port  
Audio Channel port  
enable the low bandwidth environment  
disable the low bandwidth environment  
no  
78  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
ftp1  
<domain name or IP address>  
primary FTP server  
ftpuser1  
ftppass1  
<text string shorter than 15 characters> user name for primary FTP server  
<text string shorter than 15 characters> password for primary FTP server  
ftpfolder1 <text string shorter than 40 characters> upload folder in primary FTP server  
ftp2  
<domain name or IP address>  
secondary FTP server  
ftpuser2  
ftppass2  
<text string shorter than 15 characters> user name for secondary FTP server  
<text string shorter than 15 characters> password for secondary FTP server  
ftpfolder2 <text string shorter than 40 characters> upload folder in secondary FTP server  
Video configuration URL  
URL:  
NAME  
text  
/setup/video.cgi  
VALUE  
DESCRIPTION  
<text string shorter than 15 characters> enclose caption  
size  
1
half  
2
half x 2  
3
normal  
quality  
quan  
fixb  
fix bit rate  
<other than fixb>  
fix quantization  
1
lowest quality of video  
lower quality of video  
normal quality of video  
higher quality of video  
highest quality of video  
set bit rate to 64K bps  
set bit rate to 128K bps  
set bit rate to 256K bps  
set bit rate to 384K bps  
set bit rate to 512K bps  
set bit rate to 768K bps  
set bit rate to 1000K bps  
2
3
4
5
bitrate  
64000  
128000  
256000  
384000  
512000  
768000  
1000000  
79  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1200000  
set bit rate to 1200K bps  
set maximum frame rate to 1 fps  
set maximum frame rate to 2 fps  
set maximum frame rate to 3 fps  
set maximum frame rate to 5 fps  
set maximum frame rate to 10 fps  
set maximum frame rate to 15 fps  
set maximum frame rate to 20 fps  
set maximum frame rate to 25 fps  
set maximum frame rate to 30 fps  
enable motion detection  
disable motion detection  
flip image  
frame  
1
2
3
5
10  
15  
20  
25  
30  
enablemd yes  
<other than yes>  
yes  
flip  
<other than yes>  
yes  
normal image  
mirror  
mirror image  
<other than yes>  
normal image  
Image quality configuration URL  
URL:  
/setup/image.cgi  
NAME  
VALUE  
DESCRIPTION  
brightness <-5 ~ 5>  
adjust brightness of image  
adjust contrast of image  
adjust hue of image  
contrast  
hue  
<-5 ~ 5>  
<-5 ~ 5>  
saturation <-5 ~ 5>  
adjust saturation of image  
not save the parameters  
recall the original settings  
save the parameters  
preview  
restore  
save  
<not required>  
<not required>  
<not required>  
80  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Camera configuration URL  
URL:  
/setup/camera.cgi  
NAME  
VALUE  
DESCRIPTION  
interface RS232  
<other than RS232>  
Yes  
switch COM to RS232  
switch COM to RS485  
Enable control PT device  
camctrl  
<other than yes>  
Disable control PT device  
baud  
data  
stop  
<integer>  
<integer>  
1
set baud rate of COM  
set data bits of COM  
set 1 stop bit of COM  
2 <other than 1>  
None  
set 2 stop bits of COM  
parity  
set parity check of COM to none  
set parity check of COM to odd  
set parity check of COM to even  
Odd  
Even  
up  
<text string shorter than 80 characters> tilt up command string of COM  
<text string shorter than 80 characters> tilt down command string of COM  
<text string shorter than 80 characters> pan left command string of COM  
<text string shorter than 80 characters> pan right command string of COM  
<text string shorter than 80 characters> home command string of COM  
down  
left  
right  
home  
Camera custom command configuration URL  
URL:  
NAME  
str1  
/setup/command.cgi  
VALUE  
DESCRIPTION  
<text string shorter than 8 characters> button name of custom command 1 of COM  
<text string shorter than 8 characters> button name of custom command 2 of COM  
<text string shorter than 8 characters> button name of custom command 3 of COM  
<text string shorter than 8 characters> button name of custom command 4 of COM  
<text string shorter than 8 characters> button name of custom command 5 of COM  
<text string shorter than 80 characters> custom command 1 of COM  
str2  
str3  
str4  
str5  
com1  
com2  
<text string shorter than 80 characters> custom command 2 of COM  
81  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
com3  
com4  
com5  
<text string shorter than 80 characters> custom command 3 of COM  
<text string shorter than 80 characters> custom command 4 of COM  
<text string shorter than 80 characters> custom command 5 of COM  
Modem configuration URL  
URL:  
/setup/modem.cgi  
NAME  
dialout  
VALUE  
DESCRIPTION  
yes  
allow NetworKam dialing out on event  
no dial-out allowed  
<other than yes>  
Tone (ATDT)  
Pulse (ATDP)  
<integer>  
method  
make modem dial in tone  
make modem dial in pulse  
redial attempts  
reatt  
discon  
init  
<integer>  
minutes delay before disconnection  
<text string shorter than 40 characters> command to initialize modem  
<text string shorter than 40 characters> phone number of primary ISP  
<text string shorter than 40 characters> user name for primary ISP  
<text string shorter than 40 characters> password for primary ISP  
<text string shorter than 40 characters> phone number of secondary ISP  
<text string shorter than 40 characters> user name for secondary ISP  
<text string shorter than 40 characters> password for secondary ISP  
phone1  
user1  
pass1  
phone2  
user2  
pass2  
Application configuration URL  
URL:  
/setup/app.cgi  
NAME  
emode  
smode  
smethod  
VALUE  
DESCRIPTION  
<not required>  
<not required>  
mail  
event mode application  
sequential mode application  
upload snapshots by email  
upload snapshots by FTP  
FTP file with date and time suffix  
seconds delay to detect next event  
ftp  
suffix  
delay  
<not required>  
<integer>  
82  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
inter  
<integer>  
seconds delay to capture post-event  
set DI high as trigger condition  
dihigh  
dilow  
< not required >  
< not required >  
< not required >  
< not required >  
< not required >  
< not required >  
< not required >  
< not required >  
set DI low as trigger condition  
dirise  
set DI rising as trigger condition  
set DI falling as trigger condition  
set motion window1 as trigger condition  
set motion window2 as trigger condition  
set motion window3 as trigger condition  
trigger DO when DI condition matched  
trigger DO when motion detected  
upload snapshot when DI condition matched  
upload snapshot when motion detected  
seconds interval for sequential mode  
time to start sequential mode  
difall  
motion1  
motion2  
motion3  
ioalarm  
mdalarm < not required >  
ioupload < not required >  
mdupload < not required >  
sinter  
sbegin  
send  
<integer>  
<hh:mm:ss>  
<hh:mm:ss>  
time to stop sequential mode  
Homepage layout configuration URL  
URL:  
/setup/layout.cgi  
NAME  
cuslogo  
VALUE  
blank  
def  
DESCRIPTION  
hide logo  
use default logo  
use image from URL  
url  
logourl  
linkurl  
cusback  
<text string shorter than 80 characters> URL of image for logo  
<text string shorter than 80 characters> URL to link when clicking on logo  
blank  
def  
hide background image  
use default background  
use image from URL  
url  
backurl  
fcolor  
<text string shorter than 80 characters> URL of image for background  
<0 ~ 15>  
<0 ~ 15>  
color index for font  
bcolor  
color index for background  
83  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix  
A. POST procedure  
After the power has been turned on, NetworKam will perform a self-diagnostic to locate any possible  
hardware defects. If the power indicator is dim at the beginning, the power fails to proceed further. While  
the POST is proceeding, the status LED indicators will keep blinking interchanged until finished or any  
fatal error happens. If either status LED indicator is dim at the beginning, the LED may be broken.  
Any possible fatal error has a special pattern shown in the following table. LED2 is the one below the  
network indicator and LED3 is the lowest one. If the POST is successful, status LED indicators will both  
shut off for a while and then light depending on the chosen network interface. If Ethernet is available,  
LED2 will flash like a heartbeat after network installation is done. Otherwise if modem is available,  
LED2 will flash alike to indicate listening for dial-in connection while LED3 is lit. If the included null  
modem cable is connected, both LEDs will stay on and then LED2 will start flashing after the connection  
from the PC is opened for configuration and LED3 stays lit.  
LED pattern after POST  
Possible failed component  
Failed function  
Video decoder  
LED2 and LED3 blink at same time U32(SAA7113)  
LED2 ON and LED3 OFF  
LED2 OFF and LED3 ON  
LED2 ON and LED3 ON  
LED2 blink and LED3 ON  
LED2 ON and LED3 blink  
U1(TM1300)  
PCI bridge of TM1300  
Ethernet controller  
Ethernet interface*  
Real-time clock  
U6(RTL8139C)  
U6(RTL8139C), U7, U8  
U22(M5823)  
U19(16C1550CJ), P2  
COM interface  
Ethernet interface failure includes not only components on board but also Ethernet cable and the  
devices of the opposite end.  
84  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
B. Frequently asked questions  
Q. What if I forget my password?  
A. Every access to NetworKam needs authentication. If you are one of the managed users, you have to  
ask the administrators for the password. If you are the administrators, there is no way to recover the root  
password. The only way to regain access to NetworKam is to utilize the default setting button on the rear  
panel to restore the factory settings and reinstall it.  
Q. Why can I not watch video from NetworKam after it is authenticated?  
A. There are many possible scenarios regarding this problem,  
1.If you have just installed NetworKam and are unable to watch the video, check the video modulation on  
the Configuration page.  
2.If NetworKam is well installed and you are accessing NetworKam for the first time using Internet  
Explorer, adjust the security level of Internet Explorer to allow installation of plug-ins.  
3.If the problem still exists after adjusting, the current users may be over the system allows.  
Q. What is the plug-in for?  
A. The plug-in provided by NetworKam is used to display motion pictures on Internet Explorer. If your  
system does not allow installation of any plug-in software, the security level of the web browser may need  
to be lowered. It is recommended that you consult your network supervisors in your office regarding  
adjustment of the security level.  
Q. Why is the timestamp different from the system time of my PC or notebook?  
A. The timestamp is based on the system time of NetworKam. It is maintained by a real-time clock inside  
and automatically synchronizes with the time server if NetworKam is connected to the Internet and the  
function is enabled. Differences of several hours may result from the time zone setting.  
Q. Why does the image not refresh regularly?  
A. In a modem environment, it is because the bandwidth of PPP connection is far less than Ethernet. If the  
difference of the timestamp is not stable, adjust the UART FIFO lower in both receiving and transmitting  
85  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
from modem property in the control panel. While in Ethernet, it may be due to time taken in storing  
snapshots into memory upon events occurring.  
Q. How does NetworKam detect the supported PTZ cameras automatically?  
A. If there is no camera detected, NetworKam will monitor the CTS of the camera control cable  
continuously. As long as the CTS is detected, NetworKam will try to handshake with supported cameras  
until a supported camera is found. There is no more camera detection once a PTZ camera is recognized.  
Q. How many users are allowed to watch NetworKam at the same time?  
A. Basically there is no limitation of users. However the video quality also depends on the network  
bandwidth. To achieve the best effect, NetworKam will allow several users to be connected. It is  
recommended to build another web server to host a large quantity of users by retrieving images from  
NetworKam periodically.  
Q. How fast is the video rate of NetworKam?  
A. The MPEG4 codec can process 30 frames per second internally. However the total performance is  
subject to many coefficients as follows:  
1. network throughput.  
2. bandwidth share.  
3. number of users.  
4. the complicated objects in view results in larger image file.  
5. the level of your PC or notebook which is responsible for displaying images.  
In general, the transfer rate in a general local network environment can achieve over 200 kilobytes per  
second and approximately 10 to 20 pictures of a normal environment per second.  
Q. How can I keep NetworKam as private as possible?  
A. NetworKam is designed for surveillance purposes and has many flexible interfaces. The user  
authentication and special confirmation in installation can keep NetworKam from unauthorized access.  
You may also change the HTTP port to non-public number. You can check the system log to examine any  
abnormal activities and trace the origins.  
86  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Q. I have a PTZ camera that is not on the supported list. How can I control it?  
A. NetworKam provides a custom camera command interface to control the cameras that are not  
supported. The details are described in the manual. Be sure the COM port settings are applied to the  
camera specification. The camera control cable included is shown in the package content. Prepare your  
own cable if necessary. The general PTZ command is composed of one start command and one stop  
command. When editing both commands in the edit box of the configuration page, use comma(s) to  
separate commands. Each comma represents 200 milliseconds. If the user has some serial control device  
other than the PTZ camera, the special URL is provided to send the desired commands. For quick access,  
integrate the URL to another homepage on your own web server.  
Q. How fast will NetworKam check the status of digital inputs?  
A. NetworKam will check input status in less than half a second. However, to avoid repeatedly checking  
conditions too often and to allow the devices connected to digital outputs to function properly,  
NetworKam will delay 3 seconds by default after each condition matches. Users may change it according  
to specific applications. During this period, any condition will be ignored.  
Q. Why can I not access NetworKam when I setup some options in the application?  
A. When NetworKam is triggered by events, snapshots will take more time to write them into memory. If  
the events occur too often, the system will always be busy storing images. It is recommended to use  
sequential mode or external recorder program to record motion pictures if the event is frequent. If you  
prefer to retrieve images via FTP, the value could be smaller since FTP responses quicker than the Web  
does. Once the system is too busy to configure, use the restore factory default and reset button to save the  
system.  
Q. I try to connect my black-and-white and color cameras with NetworKam but the image is not good.  
A. Although NetworKam allows users to choose color or black-and-white images for each camera, hybrid  
camera types may increase video processing time and reduce system performance.  
87  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C. Technical specifications  
Remote Management  
Configuration and system log can be accessed  
via Web browser and FTP application remotely.  
General I/O  
1 opto-isolated sensor input (max. 12VDC 50mA)  
1 output relay (max. 24VDC 1A, 125VAC 0.5A)  
Networking  
Alarm Features  
Protocol  
Motion detection with percentage and sensitivity  
Daily repeat timing schedule  
TCP/IP, HTTP, SMTP, FTP, Telnet, NTP, DNS and DHCP  
Modem  
3 color JPEG images for pre/post alarm image storage  
Automatic transfer of stored images via email or FTP with event-  
triggered actions  
PPP(dial-up, direct cable connection)  
Physical  
10baseT Ethernet or 100baseT Fast Ethernet  
RS232/RS485  
9 pin D-SUB RS232 or RS485 max.115.2Kbps  
Audio  
Algorithm Supported  
24K bps wideband audio coding  
PAN/TILT/ZOOM  
Video  
PT positioning device control through RS232 or RS485  
Clear-data command driver is supported  
Algorithm Supported  
MPEG4(short header mode)  
Features  
Remote Software Upgrade  
System firmware upgradeable via FTP  
Adjustable image size and quality  
Video Resolution  
NTSC  
Security  
Administrator and user group protected  
15 digits password protection  
Up to 30 frames at 176x120  
Up to 30 frames at 352X240  
PAL  
Up to 25 frames at 176x144  
Up to 25 frames at 352X288  
Optional Software  
Record and play pictures on PC hard disk  
I/O ports monitoring feature  
Camera Specification  
1/3 inch color CCD  
512(H) x 492(V)(NTSC) / 512(H) x 582(V)(PAL)  
1 Lux / F2.0  
LED Indicator  
Status indicators  
Network link indicator  
AGC, AWB, AI/AES  
Electronic shutter:  
Power  
12V DC, 1.2A external power supply  
6-15V DC, min. 15W  
1/60 (1/50) to 1/100,000 sec.  
Standard C or CS mount lens fitting  
Viewing System Requirement  
Protocol  
Standard internet TCP/IP suite  
Operating System  
Microsoft Windows,  
Browser  
Internet Explorer 4.x or above,  
88  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Electromagnetic Compatibility (EMC)  
USA - This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to  
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in  
a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed  
and used in accordance with the instructions, may cause harmful interference to radio communications. However,  
there is no guarantee that interference will not occur in a partial installation. If this equipment does cause harmful  
interference to radio or television reception, which can be determined by turning the equipment off and on, the user  
is encouraged to try to correct the interference by one or more of the following measures:  
-- Reorient or relocate the receiving antenna.  
-- Increase the seperation between the equipment and receiver.  
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
-- Consult the dealer or an experienced radio/TV technician for help.  
Shielded interface cables must be used in order to comply with emission limits.  
Europe  
- This digital equipment fulfills the requirement for radiated emission according to limit B of  
EN55022/1998, and the requirement for immunity according to EN50082-1/1992.  
Liability  
Vivotek Inc. cannot be held responsible for any technical or typographical errors and reserves the right to make  
changes to the product and manuals without prior notice. Vivotek Inc. makes no warranty of any kind with regard to  
the material contained within this document, including, but not limited to, the implied warranties of merchantability  
and fitness for a particular purpose.  
Vivotek Inc.  
web site:  
email:  
Made in Taiwan.  
Rev. 02  
©Copyright 2002. All rights reserved.  
89  
T: 886-2-22404099  
F: 886-2-22404097  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tektronix Stereo System AWG2005 User Manual
TeleAdapt MP3 Player Mini MP3 Player User Manual
Thermo Products Furnace MO 455 User Manual
Tiger Products Co Ltd Rice Cooker JAG B10G User Manual
Toro Sprinkler 53763 User Manual
Toshiba Computer Drive PX02SMF020 User Manual
Tricity Bendix Clothes Dryer TM 220 W User Manual
Uniden Cordless Telephone DXAI8580 Series User Manual
VocoPro Microphone UHF 5900 User Manual
VTech Baby Toy 91 002393 000 User Manual