Viking Ventilation Hood F21287A EN User Manual

Installation Guide  
Viking Range, LLC  
111 Front Street  
Greenwood, Mississippi 38930 USA  
(662) 455-1200  
For product information,  
call 1-888-(845-4641)  
Professional Indoor and  
Outdoor Hoods  
or visit the Viking Web site at vikingrange.com  
F21287A EN  
(071514)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions & Specifications  
IMPORTANT–Please Read and Follow!  
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator 30”, & 36”)  
W A R N I N G  
C A U T I O N  
For general ventilating use only. Do not use to  
exhaust hazardous or explosive materials and  
vapors.  
To reduce the risk of injury to persons in the  
event of a rangetop grease fire, observe the  
following. (Based on “Kitchen Firesafety Tips,”  
published by NFPA.)  
12 ”  
(30.5 cm)  
1. SMOTHER FLAMES with a close fitted lid, cookie  
sheet, or metal tray, then turn off the burner. BE  
CAREFUL TO PREVENT BURNS. If the flames do  
not go out immediately, EVACUATE AND CALL  
THE FIRE DEPARTMENT.  
10”  
(25.4 cm)  
5”  
(12.7 cm)  
2. NEVER PICK UP A FLAMING PAN. You may be  
burned.  
3. DO NOT USE WATER, including wet dishcloths or  
towels a violent steam explosion will result.  
4. Use an extinguisher ONLY if  
• You know it is a Class ABC extinguisher, and  
you already know how to operate it.  
• The fire is small and contained in the area where  
it started.  
• The fire department is being called.  
• You can fight the fire with your back to an exit.  
A
21”  
W A R N I N G  
(53.3 cm)  
TO REDUCE THE RISK OF FIRE,  
ELECTRICAL SHOCK, OR INJURY  
12 ”  
(30.5 cm)  
TO PERSONS  
A (Hood width)  
29-7/8“ (76.2 cm)  
35-7/8” (91.1 cm)  
Rangehoods must be installed with  
30”W.  
36”W.  
the ventilators that are specified on  
their carton indicating suitability with  
this model. Other ventilators cannot be substituted.  
12 ”  
(30.5 cm)  
5”  
(12.7 cm)  
A
21”  
(53.3 cm)  
A (Hood width)  
29-7/8“ (76.2 cm)  
35-7/8” (91.1 cm)  
30”W.  
36”W.  
NOTE: Optional duct cover sold separately.  
VWH 10’ H./12”H. Wall Hoods w/Standard Ventilator  
Description  
30”  
29-7/8” (75.9 cm)  
36”  
35-7/8” (91.1 cm)  
Duct cover width  
Duct cover depth  
Duct cover height  
Number of filters  
Heat lamps  
12” (30.5 cm)  
12” (30.5 cm)  
2
N/A  
Interior ventilator kit  
Interior duct size*  
Interior—Maximum amps  
460 CFM Standard  
7” (17.8 cm)  
4.9  
* Disregard when using recirculating kits.  
460 CFM blower is shipped with hood. Max duct run is 50 ft (15.2 m)  
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interior Ventilator Dimensions  
Clearance Dimensions  
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator)  
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator)  
Top View  
A
24”W.  
30”W.  
36”W.  
23-7/8” (60.6 cm)  
29-7/8” (75.9 cm)  
35-7/8” (91.1 cm)  
A
18”  
(4.6 cm)  
B
D
3-4”  
(1.9 cm)  
1/2”  
C
B
(1.3 cm)  
60”min.  
24”min.  
24”W.  
30”W.  
36”W.  
5-1/4” (13.3 cm)  
8-1/4” (20.9 cm)  
11-1/4” (28.6 cm)  
(152.4  
3-1/2”  
(8.9 cm)  
4”  
(10.2 cm)  
(61.0  
cm)  
cm)  
to  
63”max.  
to  
27”max.*  
(160.0  
(68.6  
cm)  
3-7/8”  
(9.8 cm)  
C
Electrical  
hookup  
cm)  
24”W.  
30”W.  
36”W.  
11-15/16” (30.3 cm)  
14-15/16” (37.9 cm)  
17-15/16” (45.6 cm)  
7” (17.8 cm) dia.  
duct location  
36”  
cm)  
D
(91.4  
24”W.  
30”W.  
36”W.  
5/8” (1.6 cm)  
3-5/8” (9.2 cm)  
6-5/8” (16.8 cm)  
460 CFM Interior Ventilator Installation  
* NOTE: When installing with a 24” high-shelf,  
the 27” (68.6 cm) max. dimensions must be used.  
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions & Specifications  
Clearance Dimensions  
(VWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”)  
(VWH 18”H. Wall Hoods)  
A (Hood width)  
30”W.  
36”W.  
42”W.  
48“W.  
60”W.  
29-7/8“ (76.2 cm)  
35-7/8” (91.1 cm)  
41-7/8” (106.4 cm)  
47-7/8” (121.6 cm)  
59-7/8” (152.1 cm)  
12”  
(30.5 cm)  
6”  
(15.2 cm)  
18”  
(45.7 cm)  
A
24”  
(61.0 cm)  
66”min.  
NOTE: Optional duct cover sold separately.  
(167.6  
30”min.  
cm)  
to  
72”max.  
(76.2  
VWH 18”H. Wall Hoods  
(182.9  
cm)  
to  
Description  
30”  
36”  
42”  
48”  
60”  
36”max.  
cm)  
(91.4  
cm)  
Duct cover width  
29-7/8”  
35-7/8”  
(91.1 cm)  
41-7/8”  
(106.4 cm)  
47-7/8”  
59-7/8”  
(75.9 cm)  
(121.6 cm)  
(152.1 cm)  
12” (30.5 cm)  
12” (30.5 cm)  
Duct cover depth  
Duct cover height  
Number of filters  
36”  
cm)  
2
1
2
1
2
1
3
4
(91.4  
Heat lamps  
2
3
VINV300/  
600/1200  
VINV300/  
600/1200  
VINV600/  
1200  
VINV1200*  
VINV1200*  
Interior ventilator kits  
DEV900/  
1200*  
DEV900/  
1200*  
DEV900/  
1200*  
DEV1200*/  
1500**  
DEV1200*/  
1500**  
Exterior ventilator kits  
DIL1200  
DIL1200  
DIL1200  
DIL1200  
DIL1200  
In-line ventilator kits  
Interior duct size  
7”/10”  
(17.8/25.4 cm)  
7”/10”  
7”/10”  
10”  
(25.4 cm)  
10”  
(25.4 cm)  
(17.8/25.4 cm) (17.8/25.4 cm)  
10” (24.5 cm)  
Exterior duct size  
4.2/5.2/8.2  
8.0/5.3  
4.2/5.2/8.2  
8.0/5.3  
5.2/8.2  
8.0/5.3  
10.8  
10.8  
Interior—Maximum amps  
Exterior—Maximum amps  
7.8/8.5  
7.8/8.5  
5.3/7.2  
5.3/7.2  
5.3/7.2  
9.6  
10.0  
In-Line—Maximum amps  
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-  
grill. Max duct run is 50 ft (15.2 m).  
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m)  
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-  
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.  
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Exterior Ventilator Dimensions  
Interior Ventilator Dimensions  
(VWH 18”H. Wall Hoods)  
(VWH 18”H. Wall Hoods)  
Top View  
Top View  
A
A
A
B
A
B
30”W.  
36”W.  
42”W.  
48”W.  
60”W.  
14-15/16” (37.9 cm)  
17-15/16” (45.6 cm)  
20-15/16” (53.2 cm)  
23-15/16” (60.8 cm)  
29-15/16” (76.0 cm)  
30”W.  
36”W.  
42”W.  
48”W.  
60”W.  
29-7/8” (75.9 cm)  
35-7/8” (91.1 cm)  
41-7/8” (106.4 cm)  
47-7/8” (121.6 cm)  
59-7/8” (152.1 cm)  
30”W.  
36”W.  
42”W.  
48”W.  
60”W.  
14-15/16” (37.9 cm)  
17-15/16” (45.6 cm)  
20-15/16” (53.2 cm)  
23-15/16” (60.8 cm)  
29-15/16” (76.0 cm)  
30”W.  
36”W.  
42”W.  
48”W.  
60”W.  
29-7/8” (75.9 cm)  
35-7/8” (91.1 cm)  
41-7/8” (106.4 cm)  
47-7/8” (121.6 cm)  
59-7/8” (152.1 cm)  
4-5/8”  
(11.7 cm)  
5-15/16”  
(15.1 cm)  
10” (25.4 cm)  
dia. duct location  
7”(17.8 cm)  
dia. duct location  
B
B
900 or 1200 CFM Exterior or In-Line Ventilator Installation for all  
300 or 600 CFM Interior Ventilator Installation for all Wall Hoods  
Top View  
Top View  
A
A
A
B
A
B
30”W.  
36”W.  
42”W.  
48”W.  
60”W.  
14-15/16” (37.9 cm)  
17-15/16” (45.6 cm)  
20-15/16” (53.2 cm)  
23-15/16” (60.8 cm)  
29-15/16” (76.0 cm)  
30”W.  
36”W.  
42”W.  
48”W.  
60”W.  
29-7/8” (75.9 cm)  
35-7/8” (91.1 cm)  
41-7/8” (106.4 cm)  
47-7/8” (121.6 cm)  
59-7/8” (152.1 cm)  
30”W.  
36”W.  
42”W.  
48”W.  
60”W.  
14-15/16” (37.9 cm)  
17-15/16” (45.6 cm)  
20-15/16” (53.2 cm)  
23-15/16” (60.8 cm)  
29-15/16” (76.0 cm)  
30”W.  
36”W.  
42”W.  
48”W.  
60”W.  
29-7/8” (75.9 cm)  
35-7/8” (91.1 cm)  
41-7/8” (106.4 cm)  
47-7/8” (121.6 cm)  
59-7/8” (152.1 cm)  
5-15/16”  
(15.1 cm)  
5-1/2”  
(14.0 cm)  
10” (25.4 cm)  
dia. duct location  
10” (25.4 cm)  
dia. duct location  
B
B
1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all  
Wall Hoods  
1200 CFM Interior Ventilator Installation for all Wall Hoods  
10  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions & Specifications  
Clearance Dimensions  
(VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”)  
(VWHO 18”H. Outdoor Wall Hoods)  
Seal joints with silicone.  
Provided on “T” Series only.  
18"  
cm)  
12”  
(30.5 cm)  
(45.7  
DIM “X”  
cm)  
+ 4-1/2"  
(11.4  
6”  
(15.2 cm)  
18”  
(45.7 cm)  
27"  
cm)  
(68.6  
66" mín.  
(167.6 cm)  
A (Hood width)  
A
30" mín.  
(76. 2 cm)  
27”  
cm)  
(68.6  
36”W.  
48“W.  
60”W.  
35-7/8” (91.1 cm)  
47-7/8” (121.6 cm)  
59-7/8” (152.1 cm)  
a
72" máx.  
(182.9 cm)  
a
36" máx.  
(91.4  
cm)  
NOTE: Optional duct cover sold separately.  
36"  
cm)  
VWHO 18”H. Outdoor Wall Hoods  
(91.4  
Description  
Duct cover width  
Duct cover depth  
Duct cover height  
Number of filters  
36”  
48”  
47-7/8” (121.6 cm)  
12” (30.5 cm)  
12” (30.5 cm)  
3
60”  
35-7/8” (91.1 cm)  
59-7/8” (152.1 cm)  
2
4
Interior ventilator kits  
Exterior ventilator kits  
In-line ventilator kits  
Interior duct size  
VINV1200*  
DEV1200*/1500**  
DIL1200  
VINV1200*  
VINV1200*  
DEV1200*/1500**  
DIL1200  
DEV1200*/1500**  
DIL1200  
10” (25.4 cm)  
Exterior duct size  
10” (25.4 cm)  
11.4  
Interior—Maximum amps  
Exterior—Maximum amps  
In-Line—Maximum amps  
9.0  
6.1/6.8  
7.9  
11.8  
8.8/9.5  
10.6  
Note: Outdoor Models must be installed in a covered, non-enclosed area, and should be protected from  
8.4/9.1  
10.2  
the elements as much as possible.  
The bottom of the hood should be 30” (76.2 cm) to 36” (91.4 cm) above the grill surface. The hood  
should be installed 4-1/2” (11.4 cm) plus the distance between the back trim and surface from the  
back wall. (Note: There is a 3” minimum clearance from the back trim to non-combustible surfaces,  
and a 24” minimum to combustible surfaces.) This will require building the hood out from the wall.  
Any combustible material used for this purpose must be covered with locally-supplied stainless  
steel. Viking also recommends using a backsplash.  
* A 1,200 CFM interior- or exterior-power ventilator should be used with all outdoor models and when indoor models  
are installed over range/rangetop with gas char-grill. Max duct run is 50 ft (15.2 m).  
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).  
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-  
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.  
12  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions & Specifications  
Clearance Dimensions  
(VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”)  
(VCWH Chimney Wall Hoods)  
A
A (Duct width)  
30”W.  
36”W.  
42”W.  
48“W.  
60”W.  
66”W.  
12“ (30.5 cm)  
12“ (30.5 cm)  
12“ (30.5 cm)  
18“ (45.7 cm)  
24“ (61.0 cm)  
24“ (61.0 cm)  
12”  
(30.5 cm)  
to  
24”  
(61.0 cm)  
6”  
(15.2 cm)  
B (Hood width)  
18”  
30”W.  
36”W.  
42”W.  
48“W.  
60”W.  
66”W.  
29-7/8“ (76.2 cm)  
35-7/8” (91.1 cm)  
41-7/8” (106.4 cm)  
47-7/8” (121.6 cm)  
59-7/8” (152.1 cm)  
65-7/8” (167.3 cm)  
(45.7 cm)  
B
24”  
66”min.  
(61.0 cm)  
(167.6  
30”min.  
cm)  
to  
72”max.  
NOTE: Optional duct cover sold separately.  
(76.2  
(182.9  
cm)  
to  
36”max.  
cm)  
(91.4  
cm)  
VCWH Chimney Wall Hoods  
Description  
30”  
36”  
42”  
48”  
60”  
Duct cover width  
12” (30.5 cm) 12” (30.5 cm) 12” (30.5 cm) 18” (45.7 cm) 24” (61.0 cm)  
36”  
cm)  
Duct cover depth  
Duct cover height  
Number of filters  
12” (30.5 cm)  
12” (30.5 cm) to 24” (61.0 cm)  
(91.4  
2
1
2
2
2
3
Heat lamps  
1
1
2
3
VINV300/600 VINV300/600  
VINV600  
VINV1200*  
VINV1200*  
Interior ventilator kits  
Exterior ventilator kits  
DEV900/  
1200*  
DEV900/  
1200*  
DEV900/  
1200*  
DEV1200*/  
1500**  
DEV1200*/  
1500**  
DIL1200  
DIL1200  
DIL1200  
DIL1200  
DIL1200  
In-line ventilator kits  
Interior duct size  
7” (17.8 cm)  
7” (17.8 cm)  
7” (17.8 cm) 10” (25.4 cm) 10” (25.4 cm)  
Exterior duct size  
10” (25.4 cm)  
4.2/5.2  
8.0/5.3  
4.2/5.2  
8.0/5.3  
5.2  
10.8  
10.8  
Interior—Maximum amps  
Exterior—Maximum amps  
8.0/5.3  
7.8/8.5  
7.8/8.5  
5.3/7.2  
5.3/7.2  
5.3/7.2  
9.6  
10.0  
In-Line—Maximum amps  
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-  
grill. Max duct run is 50 ft (15.2 m).  
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).  
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire  
with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.  
14  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interior Ventilator Dimensions  
Exterior Ventilator Dimensions  
(VCWH Chimney Wall Hoods)  
(VCWH Chimney Wall Hoods)  
Top View  
Top View  
120V  
power  
supply  
120V  
power  
supply  
12”  
(30.5 cm)  
1-1/2”  
(3.8 cm)  
12”  
1-1/2”  
(30.5 cm)  
(3.8 cm)  
A
A
A
A
8”  
(20.3 cm)  
8”  
(20.3 cm)  
30”W.  
36”W.  
42”W.  
14-15/16” (37.9 cm)  
17-15/16” (45.6 cm)  
20-15/16” (53.2 cm)  
30”W.  
36”W.  
42”W.  
14-15/16” (37.9 cm)  
17-15/16” (45.6 cm)  
20-15/16” (53.2 cm)  
1-1/2”  
(3.8 cm)  
1-1/2”  
(3.8 cm)  
B
B
30”W.  
36”W.  
42”W.  
29-7/8” (75.9 cm)  
35-7/8” (91.1 cm)  
41-7/8” (106.4 cm)  
30”W.  
36”W.  
42”W.  
29-7/8” (75.9 cm)  
35-7/8” (91.1 cm)  
41-7/8” (106.4 cm)  
10” (25.4 cm) dia.  
duct location  
7” (17.8 cm) dia.  
duct location  
B
B
900 or 1200 CFM Exterior or In-Line Ventilator Installation  
for 30”, 36”, & 42” models  
300 or 600 CFM Interior Ventilator Installation  
for 30”, 36”, & 42” models  
Top View  
Top View  
120 V  
power  
supply  
120 V  
power  
supply  
1-1/2”  
(3.8 cm)  
1-1/2”  
(3.8 cm)  
C
C
A
A
A
C
A
C
6”  
(15.2 cm)  
6”  
(15.2 cm)  
48”W.  
60”W.  
66”W.  
23-15/16” (60.8 cm)  
29-15/16” (76.0 cm)  
32-15/16” (83.7 cm)  
48”W.  
60”W.  
66”W.  
18” (45.7 cm)  
24” (61.0 cm)  
24” (61.0 cm)  
48”W.  
60”W.  
66”W.  
23-15/16” (60.8 cm)  
29-15/16” (76.0 cm)  
32-15/16” (83.7 cm)  
48”W.  
60”W.  
66”W.  
18” (45.7 cm)  
24” (61.0 cm)  
24” (61.0 cm)  
1-1/2”  
(3.8 cm)  
1-1/2”  
(3.8 cm)  
B
B
48”W.  
60”W.  
66”W.  
47-7/8” (121.6 cm)  
59-7/8” (152.1 cm)  
65-7/8” (167.3 cm)  
48”W.  
60”W.  
66”W.  
47-7/8” (121.6 cm)  
59-7/8” (152.1 cm)  
65-7/8” (167.3 cm)  
10” (25.4 cm) dia.  
duct location  
10” (25.4 cm) dia.  
duct location  
B
B
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation  
for 48”, & 60”models  
1200 CFM Interior Ventilator Installation  
for 48”, & 60”models  
16  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions & Specifications  
Clearance Dimensions  
(VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”)  
(VCIH Chimney Island Hoods)  
A
A (Duct width)  
12” (30.5 cm)  
12” (30.5 cm)  
18” (45.7 cm)  
24” (70.0 cm)  
36”W.  
42”W.  
54”W.  
66”W.  
6“  
cm)  
B
(15.2  
B (Duct height)  
36”W.  
42”W.  
54”W.  
66”W.  
12” (30.5 cm)  
or  
24” (61.0 cm)  
or  
18”  
(45.7 c  
36” (91.4 cm)  
m)  
C (Hood width)  
36”W.  
42”W.  
54”W.  
66”W.  
35-7/8” (91.1 cm)  
41-7/8” (106.4 cm)  
53-7/8” (136.8 cm)  
65-7/8” (167.3 cm)  
C
30”  
66”mi  
(76.2 cm)  
(167.6  
n.  
30”  
min.  
cm)  
to  
(182.9  
72”m  
(76.2  
cm)  
ax.  
to  
36”max.  
(91.4  
NOTE: Optional duct cover sold separately.  
cm)  
cm)  
VCIH Chimney Island Hoods  
Description  
36”  
42”  
54”  
66”  
24” (70.0 cm)  
36”  
cm)  
Duct cover width  
12” (30.5 cm)  
12” (30.5 cm)  
18” (45.7 cm)  
(91.4  
Duct cover depth  
Duct cover height  
Number of filters  
12” (30.5 cm)  
12” (30.5 cm) or 24” (61.0 cm) or 36” (91.4 cm)  
4
4
6
8
Heat lamps  
N/A  
VINV600  
DEV900/1200*  
DIL1200  
VINV600  
DEV900/1200*/1500**  
DIL1200  
VINV1200*  
DEV1200*/1500**  
DIL1200  
VINV1200*  
DEV1200*/1500**  
DIL1200  
Interior ventilator kits  
Exterior ventilator kits  
In-line ventilator kits  
Interior duct size  
7” (17.8 cm)  
7” (17.8 cm)  
10” (25.4 cm)  
10” (25.4 cm)  
Exterior duct size  
10” (25.4 cm)  
4.2/5.2/8.2  
7.4/4.7  
5.2/8.2  
7.4/4.7/5.5  
3.9/5.7  
8.9  
5.6/6.4  
7.4  
9.3  
6.4/7.4  
7.4  
Interior—Maximum amps  
Exterior—Maximum amps  
In-Line—Maximum amps  
4.7/6.5  
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.  
Max duct run is 50 ft (15.2 m).  
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).  
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire  
with ground. An interior or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.  
18  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Exterior Ventilator Dimensions  
Interior Ventilator Dimensions  
(VCIH Chimney Island Hoods)  
(VCIH Chimney Island Hoods)  
Top View  
Top View  
12”  
(30.5 cm)  
1-1/8”  
(2.9 cm)  
12”  
(30.5 cm)  
1-1/8”  
(2.9 cm)  
120 V  
power  
supply  
120 V  
power  
supply  
A
A
A
A
36”W.  
42”W.  
17-15/16” (45.6 cm)  
20-15/16” (53.2 cm)  
36”W.  
42”W.  
17-15/16” (45.6 cm)  
20-15/16” (53.2 cm)  
1-1/8”  
(2.9 cm)  
1-1/8”  
(2.9 cm)  
6”  
(15.2 cm)  
6”  
(15.2 cm)  
B
B
36”W.  
42”W.  
35-7/8” (91.1 cm)  
41-7/8” (106.4 cm)  
36”W.  
42”W.  
35-7/8” (91.1 cm)  
41-7/8” (106.4 cm)  
7” (17.8 cm) dia.  
duct location  
10” (25.4 cm) dia.  
duct location  
B
B
600 CFM Interior Ventilator Installation  
for all Chimney Island Hoods  
900 or 1200 CFM Exterior or In-Line Ventilator Installation  
for all Chimney Island Hoods  
Top View  
Top View  
1-1/8”  
C
1-1/8”  
(2.9 cm)  
120 V  
C
(2.9 cm)  
120 V  
power  
supply  
power  
A
A
supply  
54”W.  
66”W.  
26-15/16” (68.4 cm)  
32-15/16” (83.7 cm)  
A
54”W.  
66”W.  
26-15/16” (68.4 cm)  
32-15/16” (83.7 cm)  
A
1-1/8”  
(2.9 cm)  
1-1/8”  
(2.9 cm)  
6”  
(15.2 cm)  
B
6”  
(15.2 cm)  
B
54”W.  
66”W.  
53-7/8” (136.8 cm)  
65-7/8” (167.3 cm)  
54”W.  
66”W.  
53-7/8” (136.8 cm)  
65-7/8” (167.3 cm)  
C
C
54”W.  
66”W.  
18” (45.7 cm)  
24” (61.0 cm)  
10” (25.4 cm) dia.  
duct location  
54”W.  
66”W.  
18” (45.7 cm)  
24” (61.0 cm)  
10” (25.4 cm) dia.  
duct location  
B
B
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation  
for all Chimney Island Hoods  
1200 CFM Interior Ventilator Installation  
for all Chimney Island Hoods  
20  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions & Specifications  
Clearance Dimensions  
(VBCV Wall Custom Ventilator System 36”, 42”, 48”, & 60”)  
(Custom Hood Canopy Cutouts)  
Wall Hoods  
Custom Hood Canopy Bottom Cutout Dimensions  
Description A (Hood Width)  
A*  
36” W.  
42” W.  
48” W.  
60” W.  
33-7/16” (84.9 cm)  
39-7/16” (100.2 cm)  
45-7/16” (115.4 cm)  
57-7/16” (145.9 cm)  
(Custom Hood)  
Make sure the back  
*For best  
21-7/16”  
(54.5 cm)  
wall of the custom  
hood canopy is flush  
with the cutout so  
the ventilator system  
may be mounted as  
shown on page 25.  
results, center  
the unit over the  
burners of the  
cooking product  
(front to back;  
right to left).  
66”min.  
(167.6  
30”min.  
cm)  
(76.2 cm)  
to  
72”max.  
(182.9  
to  
36”max.  
(91.4 cm)  
cm)  
Custom Hood  
Canopy  
27-7/16”  
(54.5 cm)  
A
36”  
cm)  
(91.4  
1) Position ventilator  
system inside of the  
custom hood canopy  
and center it front to  
back and left to right.  
Built-In Ventilator  
System  
2) Bottom mounting holes  
fasten ventilator system  
to bottom of custom  
hood canopy with the  
screws provided.  
3) OPTIONAL  
Rear mounting holes fasten  
ventilator system to rear of  
custom hood canopy.  
22  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Built-In Wall Custom Ventilator  
Clearance Dimensions  
System Dimensions  
(VBCV Models)  
(VBCV Wall Custom Ventilator System)  
VBCV Wall Custom Ventilator System  
Description  
Number of filters  
Heat lamps  
36”  
42”  
48”  
60”  
2
2
3
4
1”  
1-1/2”  
1-1/2”  
7/8”  
(2.54 cm)  
1
1
2
3
(3.8 cm)  
(3.81 cm)  
(2.2 cm)  
VINV300/  
600/1200*  
VINV600/ VINV1200* VINV1200*  
1200*  
Interior ventilator kits  
DEV900/  
1200*  
DIL1200  
DEV900/  
1200*  
DIL900/1200  
DEV1200*/ DEV1200*/  
Exterior ventilator kits  
11-1/2”  
1500**  
1500**  
(29.2 cm)  
DIL1200  
DIL1200  
In-line ventilator kits  
Interior duct size  
17-1/4”  
7”/10”  
7”/10”  
10”  
10”  
17-1/4”  
(43.8 cm)  
(43.8 cm)  
(17.8/25.4 cm) (17.8/25.4 cm) (25.4 cm) (25.4 cm)  
Exterior duct size  
10” (25.4  
10.8  
6”  
(15.2 cm)  
6”  
4.2/5.2  
8.0/5.3  
10.8  
10.8  
Interior—Maximum amps  
Exterior—Maximum amps  
(15.2 cm)  
8.0/5.3  
7.8/8.5  
7.8/8.5  
21-5/16”  
(54.1 cm)  
21-5/16”  
5.3/7.2  
5.3/7.2  
9.6  
10.0  
In-Line—Maximum amps  
(54.1 cm)  
21-7/8”  
21-7/8”  
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-  
grill. Max duct run is 50 ft (15.2 m).  
(55.8 cm)  
(55.8 cm)  
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).  
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-  
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.  
For 300, 600 or 1200 CFM Interior  
Ventilator Installation  
For 900, 1200 or 1500 CFM Exterior  
or In-Line Ventilator Installation  
A
D
D
4-5/8”  
5-1/2”  
(11.7 cm)  
(14.0 cm)  
7” (17.8 cm)  
10” (25.4 cm)  
dia. duct location  
dia. duct location  
9/16” (1.4 cm)  
9/16” (1.4 cm)  
B
C
900 or 1200 CFM Exterior  
or In-Line Ventilator Installation  
36”, 42” W. Models  
300 or 600 CFM Interior  
Ventilator Installation  
36”, 42” W. Models  
36” W.  
42” W.  
48” W.  
60” W.  
A
B
25” (63.5 cm) 25” (63.5 cm) 25” (63.5 cm) 31” (78.7 cm)  
D
36” W.  
17-1/8” (43.5 cm)  
20-1/8” (51.1 cm)  
23-1/8” (58.7 cm)  
29-1/8” (74.0 cm)  
33-1/4”  
(84.5 cm)  
39-1/4”  
(99.75 cm)  
45-1/4”  
(114.3 cm)  
57-1/4”  
(144.8 cm)  
42” W.  
48” W.  
60” W.  
C
D
34-1/4”  
40-1/4”  
46-1/4”  
58-1/4”  
(87.0 cm)  
(102.2 cm)  
(117.5 cm)  
(148.0 cm)  
o
o
o
o
20  
32  
42  
49  
24  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Built-In Wall Custom Ventilator  
Planning Information  
System Dimensions  
(VBCV Models)  
Proper installation of ducting is extremely  
important to ensure maximum performance  
from any ventilation product.  
D
300 or 600 CFM  
single blower  
interior-power  
typical ductwork  
Roof cap  
7” round duct  
5-1/2”  
• All CFMs are based on tests at 0.1 static  
pressure: without applying static pressure, CFM  
would be greatly overstated.  
(14.0 cm)  
Duct cover or soffit  
• Straight runs and gradual turns are best; for  
example, each 90º elbow is equivalent to 5-10  
feet (1.52-3.05 cm) of straight run.  
• Never use flexible duct; it creates back pressure/air  
turbulence and greatly reduces performance.  
• Proper performance is dependent on proper  
ducting; make sure that a qualified and trained  
installer is used.  
• Check with a qualified and trained installer or  
local codes for makeup air requirement, if any.  
• Max. amp rating for hoods includes  
recommended ventilator kit rating; all products  
must be hard wired direct with 2-wire with ground.  
Hood  
10” (25.4 cm)  
dia. duct location  
9/16” (1.4 cm)  
1200 CFM  
Roof cap  
10” round duct  
single blower  
interior power  
typical ductwork  
C
1200 or 1500 CFM Exterior or In-Line Ventilator Installation  
48”, 60” W. Models  
Duct cover or soffit  
D
Plan where the duct work will be located. Install  
proper-sized duct work, and roof or wall cap for the  
type of blower you are using. Recommended hood  
locations for the most common installations are  
shown. Adjust your measurements for various heights  
of ceilings, soffits, cabinets, or ranges/rangetops.  
Hood  
5-1/2”  
(14.0 cm)  
900, 1200, or  
1500 CFM  
exterior power  
typical ductwork  
Exterior blower  
10” round duct  
Check Framing  
Duct cover or soffit  
10” (25.4 cm)  
dia. duct location  
9/16” (1.4 cm)  
Hood  
C
Wall Installation  
exterior power  
typical ductwork  
1200 CFM Interior Ventilator Installation  
36”, 42”, 48”, 60” W. Models  
Wall cap  
Duct  
Duct cover or soffit  
Hood  
D
C
36” W.  
42” W.  
48” W.  
60” W.  
17-1/8” (43.5 cm)  
20-1/8” (51.1 cm)  
23-1/8” (58.7 cm)  
29-1/8” (74.0 cm)  
36” W.  
42” W.  
48” W.  
60” W.  
34-1/4” (87.0 cm)  
40-1/4” (102.2 cm)  
46-1/4” (117.5 cm)  
58-1/4” (148.0 cm)  
NOTE: Because of the weight of the hood make sure  
that the mounting screws are driven into the framing  
and not just the drywall. It may be necessary to drill  
additional holes in the canopy for proper alignment.  
NOTE: Wall exhaust must be a minimum of 24” (61.0 cm)  
from ground. This may vary depending on local codes  
and geographic location.  
26  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator)  
6
2
1
5/16”  
nut driver  
5/16”  
nut driver  
CAUTION: If not using a duct cover, using screws  
provided, make sure top mounting screws are secured  
into soffit or cabinet framing. Use additional mounting  
screws, if necessary.  
CAUTION: Secure vent hood to wall using screws  
provided. Use additional mounting screws and wall  
anchors, if necessary.  
Check damper for unrestricted movement, adjust if  
necessary.  
Attach transition to damper. Seal with aluminum tape.  
8
BARE OR GREEN  
7
W A R N I N G  
3
To reduce the risk of fire, electric shock, or injury  
to persons, observe the following:  
1
1
• Use this unit only in the manner intended by the  
manufacturer. If you have any questions, contact  
the manufacturer.  
2
GREEN  
BLACK  
WHITE  
• Before servicing or cleaning unit, switch power off  
at service panel and lock service panel to prevent  
power from being switched on accidentally. When  
the service disconnecting means cannot be locked,  
securely fasten a prominent warning device, such  
as a tag, to the service panel.  
BLACK  
WHITE  
Connect black to black, white to white, and the  
green/bare wire under the green screw.  
NOTE: Housing wiring must be properly installed for  
wiring to be correct when wiring unit.  
Replace electrical box cover. Make connection to  
breaker box.  
Flip hood over and remove electrical box cover.  
5
10  
4
9
1
2
1
1
1
3
3
2
2
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Insert 6” of electrical wiring through the top of vent hood  
and secure using wiring restrain. Refer to local codes.  
Slide duct over transition and tape around joint.  
28  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Duct Cover Option  
Installation  
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator)  
(VWH 10” H./12”H. Wall Hoods w/Recirculating Kit)  
3
4
2
1
2
Attach with screws and lock washers provided.  
Attach with screws.  
W A R N I N G  
5
Measure distance from ceiling to canopy.  
Slide the duct cover in place and fasten from inside  
canopy using the sheet metal screws provided.  
To reduce the risk of fire, electric shock, or injury  
to persons, observe the following:  
• Use this unit only in the manner intended by the  
manufacturer. If you have any questions, contact  
the manufacturer.  
• Before servicing or cleaning unit, switch power off  
at service panel and lock service panel to prevent  
power from being switched on accidentally. When  
the service disconnecting means cannot be locked,  
securely fasten a prominent warning device, such  
as a tag, to the service panel.  
Installation  
Remove electrical box cover.  
(VWH 12”H. Wall Hoods w/Recirculating Kit)  
1
6
2
7
1
5/16”  
nut driver  
2
Flip hood over. Insert 6” of electrical wiring through  
the top of vent hood and secure. Refer to local codes.  
CAUTION: Secure vent hood. Make sure mounting  
screws are secured into framing. Use additional  
mounting screws and wall anchors, if necessary.  
Remove damper and discard with transition.  
Turn recirculating unit upside down. Place vent hood  
upside down on recirculating unit.  
30  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
(con’t)  
Installation  
(VWH 10” H./12”H. Wall Hoods w/Recirculating Kit)  
(VWH 18”H. Wall & VCWH Chimney Wall Hoods)  
1
BARE OR GREEN  
9
8
(4.6 cm  
-
1
3
2
1
/
1
6
1-1/2”x 3/4”  
(3.8 cm) x (1.9 cm)  
wood strip  
Slot for  
wood strip  
)
5/16”  
nut driver  
5/16”  
nut driver  
1
1
2
GREEN  
BLACK  
WHITE  
BLACK  
WHITE  
Connect black to black, white to white, and the  
green/bare wire under the green screw.  
NOTE: Housing wiring must be properly installed for  
wiring to be correct when wiring unit.  
Replace electrical box cover. Make connection to  
breaker box.  
Measure down 1-13/16 (4.6 cm) from desired height of  
hood and secure 1-1/2” x 3/4” wood strip (provided  
locally) to wall using screws provided.  
Use additional mounting screws to secure hood to  
wood strip.  
10  
11  
3
5/16”  
nut driver  
1
5/16”  
nut driver  
3
2
CAUTION: If not using a duct cover, using screws  
provided, make sure top mounting screws are secured  
into soffit or cabinet framing use additional mounting  
screws, if necessary.  
CAUTION: Secure vent hood to wall using screws  
provided. Use additional mounting screws and wall  
anchors, if necessary.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Assemble brackets to baffles and insert charcoal filters.  
13  
12  
5
4
1
1
1
1
3
2
3
2
3
2
2
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Slide spacer front over front lip. Push spacer rear up,  
then slide back over rear lip.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
32  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Duct Cover Option  
(VWH 18”H. Wall Hoods)  
Duct Cover Option  
(VCWH Chimney Wall Hoods)  
2
1
2
2
1
Measure distance from ceiling to canopy.  
Tape to avoid scratching.  
Measure distance from ceiling to canopy.  
Slide the duct cover in place and fasten from inside  
canopy using the sheet metal screws provided.  
3
4
To install ventillation kit  
refer to ventillation kit  
installation instructions.  
2
Place duct cover top inside duct cover base and lower until  
desired height is found. Mark height. Use the retaining  
nuts and bolts to fasten in place and remove tape.  
Slide the duct cover in place and fasten from inside  
canopy using the sheet metal screws provided.  
34  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
(VCIH Island Hoods)  
Installation  
(VCIH Island Hoods)  
2
1
4
3
5/16”  
nut  
driver  
Run duct work down to bottom edge of duct  
cover/soffit and secure in place. Make sure the duct  
does not stick down past the cover.  
Attach canopy to duct cover/soffit. Seal top of hood to  
duct with aluminum tape.  
Check framing where cutout will be.  
Cut appropriate size hole in ceiling. Either 7” or 10”  
depending on your specific unit and ventillator kit.  
NOTE: 200 lb. limit.  
A1  
6
5
Mounting options:  
1
1
Using duct cover with ceiling mounting  
bracket. (Option A - VCIH only)  
Using threaded rod for additional support.  
(Option B)  
Attaching hood directly to soffit or  
duct cover.  
(Skip to step 3)  
3
3
2
2
Attach duct cover to optional ceiling mounting bracket.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
Slide filter front over front lip. Push filter rear up, then  
slide back over rear lip.  
A2  
B1  
5/16”  
nut  
driver  
To install ventillation kit  
refer to ventillation kit  
installation instructions.  
Attach duct cover to ceiling. The ceiling bracket can be  
hidden by using a locally supplied trim.  
Additional support option. Drill holes in all four corners  
for threaded rod and run rods from hood to ceiling.  
36  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service & Registration  
If service is required, call your dealer or authorized service agency.  
The name of the authorized service agency can be obtained from the dealer or distributor in  
your area.  
Have the following information readily available.  
• Model number  
• Serial number  
• Date purchased  
• Name of dealer from whom purchased  
Clearly describe the problem that you are having. If you are unable to obtain the name of an  
authorized service agency, or if you continue to have service problems, contact Viking Range,  
LLC at1-888-(845-4641), online at vikingrange.com or write to:  
VIKING RANGE, LLC  
PREFERRED SERVICE  
111 Front Street  
Greenwood, Mississippi 38930 USA  
Record the information indicated below. You will need it if service is ever required. The model  
and serial number for your hood is located behind the baffle filter on the left side panel in the lower  
right corner.  
Model no._____________________ Serial no. ________________________  
Date of purchase _______________ Date installed ___________________  
Dealer’s name __________________________________________________  
Address ________________________________________________________  
_______________________________________________________________  
If service requires installation of parts, use only authorized parts to ensure protection under the  
warranty.  
THIS MANUAL SHOULD REMAIN WITH THE HOOD FOR FUTURE REFERENCE.  
38  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technicolor Thomson DVD Player DPL906VD_EN User Manual
Timex Watch W 179 US User Manual
True Fitness Elliptical Trainer 600EA User Manual
Uniden Cordless Telephone DECT2060 User Manual
Uniden Cordless Telephone XSA650 User Manual
Universal Remote Control Universal Remote UR J550TVE User Manual
Verizon Amplified Phone AD3700 User Manual
ViewSonic Personal Computer VOT120 User Manual
ViewSonic Projector VS12417 User Manual
Viking Cooktop VICU206 User Manual