Installation Guide
Viking Range, LLC
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-(845-4641)
Professional Indoor and
Outdoor Hoods
or visit the Viking Web site at vikingrange.com
F21287A EN
(071514)
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions & Specifications
IMPORTANT–Please Read and Follow!
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator 30”, & 36”)
W A R N I N G
C A U T I O N
For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
To reduce the risk of injury to persons in the
event of a rangetop grease fire, observe the
following. (Based on “Kitchen Firesafety Tips,”
published by NFPA.)
12 ”
(30.5 cm)
1. SMOTHER FLAMES with a close fitted lid, cookie
sheet, or metal tray, then turn off the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do
not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
10”
(25.4 cm)
5”
(12.7 cm)
2. NEVER PICK UP A FLAMING PAN. You may be
burned.
3. DO NOT USE WATER, including wet dishcloths or
towels a violent steam explosion will result.
4. Use an extinguisher ONLY if
• You know it is a Class ABC extinguisher, and
you already know how to operate it.
• The fire is small and contained in the area where
it started.
• The fire department is being called.
• You can fight the fire with your back to an exit.
A
21”
W A R N I N G
(53.3 cm)
TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK, OR INJURY
12 ”
(30.5 cm)
TO PERSONS
A (Hood width)
29-7/8“ (76.2 cm)
35-7/8” (91.1 cm)
Rangehoods must be installed with
30”W.
36”W.
the ventilators that are specified on
their carton indicating suitability with
this model. Other ventilators cannot be substituted.
12 ”
(30.5 cm)
5”
(12.7 cm)
A
21”
(53.3 cm)
A (Hood width)
29-7/8“ (76.2 cm)
35-7/8” (91.1 cm)
30”W.
36”W.
NOTE: Optional duct cover sold separately.
VWH 10’ H./12”H. Wall Hoods w/Standard Ventilator
Description
30”
29-7/8” (75.9 cm)
36”
35-7/8” (91.1 cm)
Duct cover width
Duct cover depth
Duct cover height
Number of filters
Heat lamps
12” (30.5 cm)
12” (30.5 cm)
2
N/A
Interior ventilator kit
Interior duct size*
Interior—Maximum amps
460 CFM Standard
7” (17.8 cm)
4.9
* Disregard when using recirculating kits.
460 CFM blower is shipped with hood. Max duct run is 50 ft (15.2 m)
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Interior Ventilator Dimensions
Clearance Dimensions
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator)
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator)
Top View
A
24”W.
30”W.
36”W.
23-7/8” (60.6 cm)
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
A
18”
(4.6 cm)
B
D
3-4”
(1.9 cm)
1/2”
C
B
(1.3 cm)
60”min.
24”min.
24”W.
30”W.
36”W.
5-1/4” (13.3 cm)
8-1/4” (20.9 cm)
11-1/4” (28.6 cm)
(152.4
3-1/2”
(8.9 cm)
4”
(10.2 cm)
(61.0
cm)
cm)
to
63”max.
to
27”max.*
(160.0
(68.6
cm)
3-7/8”
(9.8 cm)
C
Electrical
hookup
cm)
24”W.
30”W.
36”W.
11-15/16” (30.3 cm)
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
7” (17.8 cm) dia.
duct location
36”
cm)
D
(91.4
24”W.
30”W.
36”W.
5/8” (1.6 cm)
3-5/8” (9.2 cm)
6-5/8” (16.8 cm)
460 CFM Interior Ventilator Installation
* NOTE: When installing with a 24” high-shelf,
the 27” (68.6 cm) max. dimensions must be used.
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions & Specifications
Clearance Dimensions
(VWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”)
(VWH 18”H. Wall Hoods)
A (Hood width)
30”W.
36”W.
42”W.
48“W.
60”W.
29-7/8“ (76.2 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
12”
(30.5 cm)
6”
(15.2 cm)
18”
(45.7 cm)
A
24”
(61.0 cm)
66”min.
NOTE: Optional duct cover sold separately.
(167.6
30”min.
cm)
to
72”max.
(76.2
VWH 18”H. Wall Hoods
(182.9
cm)
to
Description
30”
36”
42”
48”
60”
36”max.
cm)
(91.4
cm)
Duct cover width
29-7/8”
35-7/8”
(91.1 cm)
41-7/8”
(106.4 cm)
47-7/8”
59-7/8”
(75.9 cm)
(121.6 cm)
(152.1 cm)
12” (30.5 cm)
12” (30.5 cm)
Duct cover depth
Duct cover height
Number of filters
36”
cm)
2
1
2
1
2
1
3
4
(91.4
Heat lamps
2
3
VINV300/
600/1200
VINV300/
600/1200
VINV600/
1200
VINV1200*
VINV1200*
Interior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
Exterior ventilator kits
DIL1200
DIL1200
DIL1200
DIL1200
DIL1200
In-line ventilator kits
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
7”/10”
10”
(25.4 cm)
10”
(25.4 cm)
(17.8/25.4 cm) (17.8/25.4 cm)
10” (24.5 cm)
Exterior duct size
4.2/5.2/8.2
8.0/5.3
4.2/5.2/8.2
8.0/5.3
5.2/8.2
8.0/5.3
10.8
10.8
Interior—Maximum amps
Exterior—Maximum amps
7.8/8.5
7.8/8.5
5.3/7.2
5.3/7.2
5.3/7.2
9.6
10.0
In-Line—Maximum amps
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-
grill. Max duct run is 50 ft (15.2 m).
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m)
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Exterior Ventilator Dimensions
Interior Ventilator Dimensions
(VWH 18”H. Wall Hoods)
(VWH 18”H. Wall Hoods)
Top View
Top View
A
A
A
B
A
B
30”W.
36”W.
42”W.
48”W.
60”W.
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
23-15/16” (60.8 cm)
29-15/16” (76.0 cm)
30”W.
36”W.
42”W.
48”W.
60”W.
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
30”W.
36”W.
42”W.
48”W.
60”W.
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
23-15/16” (60.8 cm)
29-15/16” (76.0 cm)
30”W.
36”W.
42”W.
48”W.
60”W.
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
4-5/8”
(11.7 cm)
5-15/16”
(15.1 cm)
10” (25.4 cm)
dia. duct location
7”(17.8 cm)
dia. duct location
B
B
900 or 1200 CFM Exterior or In-Line Ventilator Installation for all
300 or 600 CFM Interior Ventilator Installation for all Wall Hoods
Top View
Top View
A
A
A
B
A
B
30”W.
36”W.
42”W.
48”W.
60”W.
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
23-15/16” (60.8 cm)
29-15/16” (76.0 cm)
30”W.
36”W.
42”W.
48”W.
60”W.
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
30”W.
36”W.
42”W.
48”W.
60”W.
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
23-15/16” (60.8 cm)
29-15/16” (76.0 cm)
30”W.
36”W.
42”W.
48”W.
60”W.
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
5-15/16”
(15.1 cm)
5-1/2”
(14.0 cm)
10” (25.4 cm)
dia. duct location
10” (25.4 cm)
dia. duct location
B
B
1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all
Wall Hoods
1200 CFM Interior Ventilator Installation for all Wall Hoods
10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions & Specifications
Clearance Dimensions
(VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”)
(VWHO 18”H. Outdoor Wall Hoods)
Seal joints with silicone.
Provided on “T” Series only.
18"
cm)
12”
(30.5 cm)
(45.7
DIM “X”
cm)
+ 4-1/2"
(11.4
6”
(15.2 cm)
18”
(45.7 cm)
27"
cm)
(68.6
66" mín.
(167.6 cm)
A (Hood width)
A
30" mín.
(76. 2 cm)
27”
cm)
(68.6
36”W.
48“W.
60”W.
35-7/8” (91.1 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
a
72" máx.
(182.9 cm)
a
36" máx.
(91.4
cm)
NOTE: Optional duct cover sold separately.
36"
cm)
VWHO 18”H. Outdoor Wall Hoods
(91.4
Description
Duct cover width
Duct cover depth
Duct cover height
Number of filters
36”
48”
47-7/8” (121.6 cm)
12” (30.5 cm)
12” (30.5 cm)
3
60”
35-7/8” (91.1 cm)
59-7/8” (152.1 cm)
2
4
Interior ventilator kits
Exterior ventilator kits
In-line ventilator kits
Interior duct size
VINV1200*
DEV1200*/1500**
DIL1200
VINV1200*
VINV1200*
DEV1200*/1500**
DIL1200
DEV1200*/1500**
DIL1200
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
11.4
Interior—Maximum amps
Exterior—Maximum amps
In-Line—Maximum amps
9.0
6.1/6.8
7.9
11.8
8.8/9.5
10.6
Note: Outdoor Models must be installed in a covered, non-enclosed area, and should be protected from
8.4/9.1
10.2
the elements as much as possible.
The bottom of the hood should be 30” (76.2 cm) to 36” (91.4 cm) above the grill surface. The hood
should be installed 4-1/2” (11.4 cm) plus the distance between the back trim and surface from the
back wall. (Note: There is a 3” minimum clearance from the back trim to non-combustible surfaces,
and a 24” minimum to combustible surfaces.) This will require building the hood out from the wall.
Any combustible material used for this purpose must be covered with locally-supplied stainless
steel. Viking also recommends using a backsplash.
* A 1,200 CFM interior- or exterior-power ventilator should be used with all outdoor models and when indoor models
are installed over range/rangetop with gas char-grill. Max duct run is 50 ft (15.2 m).
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
12
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions & Specifications
Clearance Dimensions
(VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”)
(VCWH Chimney Wall Hoods)
A
A (Duct width)
30”W.
36”W.
42”W.
48“W.
60”W.
66”W.
12“ (30.5 cm)
12“ (30.5 cm)
12“ (30.5 cm)
18“ (45.7 cm)
24“ (61.0 cm)
24“ (61.0 cm)
12”
(30.5 cm)
to
24”
(61.0 cm)
6”
(15.2 cm)
B (Hood width)
18”
30”W.
36”W.
42”W.
48“W.
60”W.
66”W.
29-7/8“ (76.2 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
65-7/8” (167.3 cm)
(45.7 cm)
B
24”
66”min.
(61.0 cm)
(167.6
30”min.
cm)
to
72”max.
NOTE: Optional duct cover sold separately.
(76.2
(182.9
cm)
to
36”max.
cm)
(91.4
cm)
VCWH Chimney Wall Hoods
Description
30”
36”
42”
48”
60”
Duct cover width
12” (30.5 cm) 12” (30.5 cm) 12” (30.5 cm) 18” (45.7 cm) 24” (61.0 cm)
36”
cm)
Duct cover depth
Duct cover height
Number of filters
12” (30.5 cm)
12” (30.5 cm) to 24” (61.0 cm)
(91.4
2
1
2
2
2
3
Heat lamps
1
1
2
3
VINV300/600 VINV300/600
VINV600
VINV1200*
VINV1200*
Interior ventilator kits
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
DIL1200
DIL1200
DIL1200
DIL1200
DIL1200
In-line ventilator kits
Interior duct size
7” (17.8 cm)
7” (17.8 cm)
7” (17.8 cm) 10” (25.4 cm) 10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
4.2/5.2
8.0/5.3
4.2/5.2
8.0/5.3
5.2
10.8
10.8
Interior—Maximum amps
Exterior—Maximum amps
8.0/5.3
7.8/8.5
7.8/8.5
5.3/7.2
5.3/7.2
5.3/7.2
9.6
10.0
In-Line—Maximum amps
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-
grill. Max duct run is 50 ft (15.2 m).
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire
with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
14
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Interior Ventilator Dimensions
Exterior Ventilator Dimensions
(VCWH Chimney Wall Hoods)
(VCWH Chimney Wall Hoods)
Top View
Top View
120V
power
supply
120V
power
supply
12”
(30.5 cm)
1-1/2”
(3.8 cm)
12”
1-1/2”
(30.5 cm)
(3.8 cm)
A
A
A
A
8”
(20.3 cm)
8”
(20.3 cm)
30”W.
36”W.
42”W.
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
30”W.
36”W.
42”W.
14-15/16” (37.9 cm)
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
1-1/2”
(3.8 cm)
1-1/2”
(3.8 cm)
B
B
30”W.
36”W.
42”W.
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
30”W.
36”W.
42”W.
29-7/8” (75.9 cm)
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
10” (25.4 cm) dia.
duct location
7” (17.8 cm) dia.
duct location
B
B
900 or 1200 CFM Exterior or In-Line Ventilator Installation
for 30”, 36”, & 42” models
300 or 600 CFM Interior Ventilator Installation
for 30”, 36”, & 42” models
Top View
Top View
120 V
power
supply
120 V
power
supply
1-1/2”
(3.8 cm)
1-1/2”
(3.8 cm)
C
C
A
A
A
C
A
C
6”
(15.2 cm)
6”
(15.2 cm)
48”W.
60”W.
66”W.
23-15/16” (60.8 cm)
29-15/16” (76.0 cm)
32-15/16” (83.7 cm)
48”W.
60”W.
66”W.
18” (45.7 cm)
24” (61.0 cm)
24” (61.0 cm)
48”W.
60”W.
66”W.
23-15/16” (60.8 cm)
29-15/16” (76.0 cm)
32-15/16” (83.7 cm)
48”W.
60”W.
66”W.
18” (45.7 cm)
24” (61.0 cm)
24” (61.0 cm)
1-1/2”
(3.8 cm)
1-1/2”
(3.8 cm)
B
B
48”W.
60”W.
66”W.
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
65-7/8” (167.3 cm)
48”W.
60”W.
66”W.
47-7/8” (121.6 cm)
59-7/8” (152.1 cm)
65-7/8” (167.3 cm)
10” (25.4 cm) dia.
duct location
10” (25.4 cm) dia.
duct location
B
B
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for 48”, & 60”models
1200 CFM Interior Ventilator Installation
for 48”, & 60”models
16
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions & Specifications
Clearance Dimensions
(VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”)
(VCIH Chimney Island Hoods)
A
A (Duct width)
12” (30.5 cm)
12” (30.5 cm)
18” (45.7 cm)
24” (70.0 cm)
36”W.
42”W.
54”W.
66”W.
6“
cm)
B
(15.2
B (Duct height)
36”W.
42”W.
54”W.
66”W.
12” (30.5 cm)
or
24” (61.0 cm)
or
18”
(45.7 c
36” (91.4 cm)
m)
C (Hood width)
36”W.
42”W.
54”W.
66”W.
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
53-7/8” (136.8 cm)
65-7/8” (167.3 cm)
C
30”
66”mi
(76.2 cm)
(167.6
n.
30”
min.
cm)
to
(182.9
72”m
(76.2
cm)
ax.
to
36”max.
(91.4
NOTE: Optional duct cover sold separately.
cm)
cm)
VCIH Chimney Island Hoods
Description
36”
42”
54”
66”
24” (70.0 cm)
36”
cm)
Duct cover width
12” (30.5 cm)
12” (30.5 cm)
18” (45.7 cm)
(91.4
Duct cover depth
Duct cover height
Number of filters
12” (30.5 cm)
12” (30.5 cm) or 24” (61.0 cm) or 36” (91.4 cm)
4
4
6
8
Heat lamps
N/A
VINV600
DEV900/1200*
DIL1200
VINV600
DEV900/1200*/1500**
DIL1200
VINV1200*
DEV1200*/1500**
DIL1200
VINV1200*
DEV1200*/1500**
DIL1200
Interior ventilator kits
Exterior ventilator kits
In-line ventilator kits
Interior duct size
7” (17.8 cm)
7” (17.8 cm)
10” (25.4 cm)
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
4.2/5.2/8.2
7.4/4.7
5.2/8.2
7.4/4.7/5.5
3.9/5.7
8.9
5.6/6.4
7.4
9.3
6.4/7.4
7.4
Interior—Maximum amps
Exterior—Maximum amps
In-Line—Maximum amps
4.7/6.5
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft (15.2 m).
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire
with ground. An interior or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
18
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Exterior Ventilator Dimensions
Interior Ventilator Dimensions
(VCIH Chimney Island Hoods)
(VCIH Chimney Island Hoods)
Top View
Top View
12”
(30.5 cm)
1-1/8”
(2.9 cm)
12”
(30.5 cm)
1-1/8”
(2.9 cm)
120 V
power
supply
120 V
power
supply
A
A
A
A
36”W.
42”W.
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
36”W.
42”W.
17-15/16” (45.6 cm)
20-15/16” (53.2 cm)
1-1/8”
(2.9 cm)
1-1/8”
(2.9 cm)
6”
(15.2 cm)
6”
(15.2 cm)
B
B
36”W.
42”W.
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
36”W.
42”W.
35-7/8” (91.1 cm)
41-7/8” (106.4 cm)
7” (17.8 cm) dia.
duct location
10” (25.4 cm) dia.
duct location
B
B
600 CFM Interior Ventilator Installation
for all Chimney Island Hoods
900 or 1200 CFM Exterior or In-Line Ventilator Installation
for all Chimney Island Hoods
Top View
Top View
1-1/8”
C
1-1/8”
(2.9 cm)
120 V
C
(2.9 cm)
120 V
power
supply
power
A
A
supply
54”W.
66”W.
26-15/16” (68.4 cm)
32-15/16” (83.7 cm)
A
54”W.
66”W.
26-15/16” (68.4 cm)
32-15/16” (83.7 cm)
A
1-1/8”
(2.9 cm)
1-1/8”
(2.9 cm)
6”
(15.2 cm)
B
6”
(15.2 cm)
B
54”W.
66”W.
53-7/8” (136.8 cm)
65-7/8” (167.3 cm)
54”W.
66”W.
53-7/8” (136.8 cm)
65-7/8” (167.3 cm)
C
C
54”W.
66”W.
18” (45.7 cm)
24” (61.0 cm)
10” (25.4 cm) dia.
duct location
54”W.
66”W.
18” (45.7 cm)
24” (61.0 cm)
10” (25.4 cm) dia.
duct location
B
B
900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for all Chimney Island Hoods
1200 CFM Interior Ventilator Installation
for all Chimney Island Hoods
20
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions & Specifications
Clearance Dimensions
(VBCV Wall Custom Ventilator System 36”, 42”, 48”, & 60”)
(Custom Hood Canopy Cutouts)
Wall Hoods
Custom Hood Canopy Bottom Cutout Dimensions
Description A (Hood Width)
A*
36” W.
42” W.
48” W.
60” W.
33-7/16” (84.9 cm)
39-7/16” (100.2 cm)
45-7/16” (115.4 cm)
57-7/16” (145.9 cm)
(Custom Hood)
Make sure the back
*For best
21-7/16”
(54.5 cm)
wall of the custom
hood canopy is flush
with the cutout so
the ventilator system
may be mounted as
shown on page 25.
results, center
the unit over the
burners of the
cooking product
(front to back;
right to left).
66”min.
(167.6
30”min.
cm)
(76.2 cm)
to
72”max.
(182.9
to
36”max.
(91.4 cm)
cm)
Custom Hood
Canopy
27-7/16”
(54.5 cm)
A
36”
cm)
(91.4
1) Position ventilator
system inside of the
custom hood canopy
and center it front to
back and left to right.
Built-In Ventilator
System
2) Bottom mounting holes
fasten ventilator system
to bottom of custom
hood canopy with the
screws provided.
3) OPTIONAL
Rear mounting holes fasten
ventilator system to rear of
custom hood canopy.
22
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Built-In Wall Custom Ventilator
Clearance Dimensions
System Dimensions
(VBCV Models)
(VBCV Wall Custom Ventilator System)
VBCV Wall Custom Ventilator System
Description
Number of filters
Heat lamps
36”
42”
48”
60”
2
2
3
4
1”
1-1/2”
1-1/2”
7/8”
(2.54 cm)
1
1
2
3
(3.8 cm)
(3.81 cm)
(2.2 cm)
VINV300/
600/1200*
VINV600/ VINV1200* VINV1200*
1200*
Interior ventilator kits
DEV900/
1200*
DIL1200
DEV900/
1200*
DIL900/1200
DEV1200*/ DEV1200*/
Exterior ventilator kits
11-1/2”
1500**
1500**
(29.2 cm)
DIL1200
DIL1200
In-line ventilator kits
Interior duct size
17-1/4”
7”/10”
7”/10”
10”
10”
17-1/4”
(43.8 cm)
(43.8 cm)
(17.8/25.4 cm) (17.8/25.4 cm) (25.4 cm) (25.4 cm)
Exterior duct size
10” (25.4
10.8
6”
(15.2 cm)
6”
4.2/5.2
8.0/5.3
10.8
10.8
Interior—Maximum amps
Exterior—Maximum amps
(15.2 cm)
8.0/5.3
7.8/8.5
7.8/8.5
21-5/16”
(54.1 cm)
21-5/16”
5.3/7.2
5.3/7.2
9.6
10.0
In-Line—Maximum amps
(54.1 cm)
21-7/8”
21-7/8”
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-
grill. Max duct run is 50 ft (15.2 m).
(55.8 cm)
(55.8 cm)
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m).
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
For 300, 600 or 1200 CFM Interior
Ventilator Installation
For 900, 1200 or 1500 CFM Exterior
or In-Line Ventilator Installation
A
D
D
4-5/8”
5-1/2”
(11.7 cm)
(14.0 cm)
7” (17.8 cm)
10” (25.4 cm)
dia. duct location
dia. duct location
9/16” (1.4 cm)
9/16” (1.4 cm)
B
C
900 or 1200 CFM Exterior
or In-Line Ventilator Installation
36”, 42” W. Models
300 or 600 CFM Interior
Ventilator Installation
36”, 42” W. Models
36” W.
42” W.
48” W.
60” W.
A
B
25” (63.5 cm) 25” (63.5 cm) 25” (63.5 cm) 31” (78.7 cm)
D
36” W.
17-1/8” (43.5 cm)
20-1/8” (51.1 cm)
23-1/8” (58.7 cm)
29-1/8” (74.0 cm)
33-1/4”
(84.5 cm)
39-1/4”
(99.75 cm)
45-1/4”
(114.3 cm)
57-1/4”
(144.8 cm)
42” W.
48” W.
60” W.
C
D
34-1/4”
40-1/4”
46-1/4”
58-1/4”
(87.0 cm)
(102.2 cm)
(117.5 cm)
(148.0 cm)
o
o
o
o
20
32
42
49
24
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Built-In Wall Custom Ventilator
Planning Information
System Dimensions
(VBCV Models)
Proper installation of ducting is extremely
important to ensure maximum performance
from any ventilation product.
D
300 or 600 CFM
single blower
interior-power
typical ductwork
Roof cap
7” round duct
5-1/2”
• All CFMs are based on tests at 0.1 static
pressure: without applying static pressure, CFM
would be greatly overstated.
(14.0 cm)
Duct cover or soffit
• Straight runs and gradual turns are best; for
example, each 90º elbow is equivalent to 5-10
feet (1.52-3.05 cm) of straight run.
• Never use flexible duct; it creates back pressure/air
turbulence and greatly reduces performance.
• Proper performance is dependent on proper
ducting; make sure that a qualified and trained
installer is used.
• Check with a qualified and trained installer or
local codes for makeup air requirement, if any.
• Max. amp rating for hoods includes
recommended ventilator kit rating; all products
must be hard wired direct with 2-wire with ground.
Hood
10” (25.4 cm)
dia. duct location
9/16” (1.4 cm)
1200 CFM
Roof cap
10” round duct
single blower
interior power
typical ductwork
C
1200 or 1500 CFM Exterior or In-Line Ventilator Installation
48”, 60” W. Models
Duct cover or soffit
D
Plan where the duct work will be located. Install
proper-sized duct work, and roof or wall cap for the
type of blower you are using. Recommended hood
locations for the most common installations are
shown. Adjust your measurements for various heights
of ceilings, soffits, cabinets, or ranges/rangetops.
Hood
5-1/2”
(14.0 cm)
900, 1200, or
1500 CFM
exterior power
typical ductwork
Exterior blower
10” round duct
Check Framing
Duct cover or soffit
10” (25.4 cm)
dia. duct location
9/16” (1.4 cm)
Hood
C
Wall Installation
exterior power
typical ductwork
1200 CFM Interior Ventilator Installation
36”, 42”, 48”, 60” W. Models
Wall cap
Duct
Duct cover or soffit
Hood
D
C
36” W.
42” W.
48” W.
60” W.
17-1/8” (43.5 cm)
20-1/8” (51.1 cm)
23-1/8” (58.7 cm)
29-1/8” (74.0 cm)
36” W.
42” W.
48” W.
60” W.
34-1/4” (87.0 cm)
40-1/4” (102.2 cm)
46-1/4” (117.5 cm)
58-1/4” (148.0 cm)
NOTE: Because of the weight of the hood make sure
that the mounting screws are driven into the framing
and not just the drywall. It may be necessary to drill
additional holes in the canopy for proper alignment.
NOTE: Wall exhaust must be a minimum of 24” (61.0 cm)
from ground. This may vary depending on local codes
and geographic location.
26
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator)
6
2
1
5/16”
nut driver
5/16”
nut driver
CAUTION: If not using a duct cover, using screws
provided, make sure top mounting screws are secured
into soffit or cabinet framing. Use additional mounting
screws, if necessary.
CAUTION: Secure vent hood to wall using screws
provided. Use additional mounting screws and wall
anchors, if necessary.
Check damper for unrestricted movement, adjust if
necessary.
Attach transition to damper. Seal with aluminum tape.
8
BARE OR GREEN
7
W A R N I N G
3
To reduce the risk of fire, electric shock, or injury
to persons, observe the following:
1
1
• Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
2
GREEN
BLACK
WHITE
• Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.
BLACK
WHITE
Connect black to black, white to white, and the
green/bare wire under the green screw.
NOTE: Housing wiring must be properly installed for
wiring to be correct when wiring unit.
Replace electrical box cover. Make connection to
breaker box.
Flip hood over and remove electrical box cover.
5
10
4
9
1
2
1
1
1
3
3
2
2
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Insert 6” of electrical wiring through the top of vent hood
and secure using wiring restrain. Refer to local codes.
Slide duct over transition and tape around joint.
28
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Duct Cover Option
Installation
(VWH 10” H./12”H. Wall Hoods w/Standard Ventilator)
(VWH 10” H./12”H. Wall Hoods w/Recirculating Kit)
3
4
2
1
2
Attach with screws and lock washers provided.
Attach with screws.
W A R N I N G
5
Measure distance from ceiling to canopy.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
To reduce the risk of fire, electric shock, or injury
to persons, observe the following:
• Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
• Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.
Installation
Remove electrical box cover.
(VWH 12”H. Wall Hoods w/Recirculating Kit)
1
6
2
7
1
5/16”
nut driver
2
Flip hood over. Insert 6” of electrical wiring through
the top of vent hood and secure. Refer to local codes.
CAUTION: Secure vent hood. Make sure mounting
screws are secured into framing. Use additional
mounting screws and wall anchors, if necessary.
Remove damper and discard with transition.
Turn recirculating unit upside down. Place vent hood
upside down on recirculating unit.
30
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
(con’t)
Installation
(VWH 10” H./12”H. Wall Hoods w/Recirculating Kit)
(VWH 18”H. Wall & VCWH Chimney Wall Hoods)
1
BARE OR GREEN
9
8
(4.6 cm
-
1
3
2
1
/
1
6
”
1-1/2”x 3/4”
(3.8 cm) x (1.9 cm)
wood strip
Slot for
wood strip
)
5/16”
nut driver
5/16”
nut driver
1
1
2
GREEN
BLACK
WHITE
BLACK
WHITE
Connect black to black, white to white, and the
green/bare wire under the green screw.
NOTE: Housing wiring must be properly installed for
wiring to be correct when wiring unit.
Replace electrical box cover. Make connection to
breaker box.
Measure down 1-13/16 (4.6 cm) from desired height of
hood and secure 1-1/2” x 3/4” wood strip (provided
locally) to wall using screws provided.
Use additional mounting screws to secure hood to
wood strip.
10
11
3
5/16”
nut driver
1
5/16”
nut driver
3
2
CAUTION: If not using a duct cover, using screws
provided, make sure top mounting screws are secured
into soffit or cabinet framing use additional mounting
screws, if necessary.
CAUTION: Secure vent hood to wall using screws
provided. Use additional mounting screws and wall
anchors, if necessary.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Assemble brackets to baffles and insert charcoal filters.
13
12
5
4
1
1
1
1
3
2
3
2
3
2
2
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Slide spacer front over front lip. Push spacer rear up,
then slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
32
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Duct Cover Option
(VWH 18”H. Wall Hoods)
Duct Cover Option
(VCWH Chimney Wall Hoods)
2
1
2
2
1
Measure distance from ceiling to canopy.
Tape to avoid scratching.
Measure distance from ceiling to canopy.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
3
4
To install ventillation kit
refer to ventillation kit
installation instructions.
2
Place duct cover top inside duct cover base and lower until
desired height is found. Mark height. Use the retaining
nuts and bolts to fasten in place and remove tape.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
34
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
(VCIH Island Hoods)
Installation
(VCIH Island Hoods)
2
1
4
3
5/16”
nut
driver
Run duct work down to bottom edge of duct
cover/soffit and secure in place. Make sure the duct
does not stick down past the cover.
Attach canopy to duct cover/soffit. Seal top of hood to
duct with aluminum tape.
Check framing where cutout will be.
Cut appropriate size hole in ceiling. Either 7” or 10”
depending on your specific unit and ventillator kit.
NOTE: 200 lb. limit.
A1
6
5
Mounting options:
1
1
Using duct cover with ceiling mounting
bracket. (Option A - VCIH only)
Using threaded rod for additional support.
(Option B)
Attaching hood directly to soffit or
duct cover.
(Skip to step 3)
3
3
2
2
Attach duct cover to optional ceiling mounting bracket.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
A2
B1
5/16”
nut
driver
To install ventillation kit
refer to ventillation kit
installation instructions.
Attach duct cover to ceiling. The ceiling bracket can be
hidden by using a locally supplied trim.
Additional support option. Drill holes in all four corners
for threaded rod and run rods from hood to ceiling.
36
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Service & Registration
If service is required, call your dealer or authorized service agency.
The name of the authorized service agency can be obtained from the dealer or distributor in
your area.
Have the following information readily available.
• Model number
• Serial number
• Date purchased
• Name of dealer from whom purchased
Clearly describe the problem that you are having. If you are unable to obtain the name of an
authorized service agency, or if you continue to have service problems, contact Viking Range,
LLC at1-888-(845-4641), online at vikingrange.com or write to:
VIKING RANGE, LLC
PREFERRED SERVICE
111 Front Street
Greenwood, Mississippi 38930 USA
Record the information indicated below. You will need it if service is ever required. The model
and serial number for your hood is located behind the baffle filter on the left side panel in the lower
right corner.
Model no._____________________ Serial no. ________________________
Date of purchase _______________ Date installed ___________________
Dealer’s name __________________________________________________
Address ________________________________________________________
_______________________________________________________________
If service requires installation of parts, use only authorized parts to ensure protection under the
warranty.
THIS MANUAL SHOULD REMAIN WITH THE HOOD FOR FUTURE REFERENCE.