Vicks Air Cleaner HFD 135 User Manual

HFD-135 OM English.qxd 10/14/05 5:35 PM Page 1  
IFDHIGH PERFORMANCE  
AIR PURIFIER  
Model HFD-135  
9. Do not use air purifier where combustible  
gases, vapors or an oxygen rich environment  
are present.  
IMPORTANT SAFETY  
INSTRUCTIONS  
10. Do not expose the air purifier to rain, or use  
near water, in a bathroom, laundry area or  
other damp location.  
READ AND SAVE THESE SAFETY  
INSTRUCTIONS BEFORE USING  
THIS AIR PURIFIER  
11. The air purifier must be used in its upright  
position.  
12. Do not allow foreign objects to enter ventilation  
or exhaust opening as this may cause electric  
shock or damage to the air purifier. Do not  
block air outlets or intakes.  
When using electrical appliances, basic  
precautions should always be followed to  
reduce the risk of fire, electric shock, and  
injury to persons, including the following:  
13. Locate air purifier near the outlet and avoid  
using an extension cord.  
1. Read all instructions before operating the air  
14. This appliance has a polarized plug (one blade  
is wider than the other). To reduce the risk of  
shock, this plug is intended to fit only one way  
in a polarized outlet. If the plug does not fit  
fully in the outlet, reverse the plug. If it still  
does not fit, contact a qualified electrician.  
DO NOT attempt to defeat this safety feature.  
purifier.  
2. Place air purifier where it is not easily knocked  
over by persons in the household.  
3. Always turn the air purifier to the OFF position  
and unplug from the wall outlet when not in  
use.  
15. A loose fit between the AC outlet (receptacle)  
and plug may cause overheating and a  
distortion of the plug. Contact a qualified  
electrician to replace loose or worn outlet.  
4. To disconnect the air purifier, first press the  
Power ( ) button to turn the air purifier off,  
grip the plug and pull it from the wall outlet.  
Never pull by the cord.  
16. Do not sit, stand or place heavy objects on the  
5. Do not use any product with a damaged cord  
or plug or if product malfunctions, is dropped  
or damaged in any manner. Keep the cord  
away from heated surfaces.  
air purifier.  
17. Disconnect power supply before servicing.  
WARNING: To Reduce the risk of fire or electric  
shock, do not use this air purifier with any  
solid-state speed control device.  
6. Do not use air purifier outdoors.  
7. Never use air purifier unless it is fully  
assembled.  
The sealed UV bulbs contain a small amount of  
mercury. Dispose of these items at household  
hazardous waste collection sites only. If the UV  
bulb breaks, do not vacuum or handle with your  
bare hands.  
8. Do not run power cord under carpets, and do  
not cover with throw rugs. Arrange cord such  
that it will not be tripped over.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HFD-135 OM English.qxd 10/14/05 5:35 PM Page 3  
OPERATION  
• Ensure the air purifier is plugged into a working outlet.  
• Touch the Power ( ) button to turn the air purifier On.  
The LCD screen will display the current setting. (Fig. 2).  
Fig. 1  
Power Button  
Speed +/– Buttons  
Filter Reset  
Button  
UV Reset  
Button  
• When first starting the unit, you can hear a change in speed  
and this is normal.  
• To change speeds, press the up (  
) or down (  
)
buttons. The display will indicate the current setting:  
Low ( ), Medium ( ), High ( ).  
Timer Button  
• For best results, set the unit to operate at High ( ) speed.  
For quieter settings, or during sleep, set the unit to Medium  
Timer +/–  
Buttons  
UV Button  
(
) or Low ( ).  
Fig. 2  
Indicates continuous operation  
• Note that during normal operation, the rotating continuous  
operation symbol ( ) will appear in place of timer hours.  
• To turn the unit off, touch the Power ( ) button.  
Timer Operation  
Once the air purifier is turned on, you can program this unit to  
turn off automatically after a set amount of time.  
• Press the Timer button – the LCD screen flashes the number  
18 (Fig. 3).  
Fig. 3  
• Press the timer plus (  
) or timer minus (  
) buttons to  
increase or decrease the desired number of hours (1 to 18).  
The selected number will flash for a few seconds – once it  
stops flashing, the air purifier is in Timer mode.  
(Example: If you want the unit to turn off in 6 hours, touch  
the Timer button, then press the timer minus (  
until the number "6" is displayed.)  
) button  
• The Timer button will be illuminated in Timer mode and the number of hours remaining will be displayed.  
• To turn the Timer mode off, press the Timer button. The continuous operation icon ( ) will appear.  
DUAL UV LAMP OPERATION  
• Press the UV button to turn the Lamps on or off (Fig. 4).  
Fig. 4  
• The Lamps will light and you will see a faint blue glow  
along the top grille of the unit. This is a visual effect. The  
UV bulbs are located in the lower portion of the unit.  
• The UV button will be illuminated on the control panel.  
NOTE: Removing the IFDfilter assembly or UV cover or  
turning the unit off will cancel the UV Lamp function.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
HFD-135 OM English.qxd 10/14/05 5:35 PM Page 4  
REMOVING / CLEANING THE IFDFILTER  
This IFDair purifier is equipped with an electronic filter  
Fig. 5  
indicator to serve as a convenient guideline for cleaning the  
IFDand pre-filter based on the air purifier’s hours of use  
and operating power level. This is beneficial because a  
filter’s life depends on the amount of air and contaminants  
drawn through it. As you operate your IFDAir Purifier, the  
filter bar indicator will fill-up from left to right. The bar will  
continue to fill as you use the unit. Once the bar is  
completely full, the Filter Reset button will illuminate – it is  
time to clean the filters and reset the filter indicator.  
Fig. 7  
Fig. 6  
To reset the filter clean indicator:  
• With the power on, press and hold the Filter Reset button  
for 10 seconds, or until the filter bar clears itself (Fig. 5).  
NOTE: Depending upon your individual usage (environment,  
hours and power level of operation), you may need to check  
and clean the filters more or less frequently.  
To remove the IFDfilter:  
Fig. 8  
Fig. 9  
• Make certain that the air purifier is OFF and the unit is  
unplugged.  
• Remove the rear door panel by turning the rear knob  
counter-clockwise and lifting the panel out and up.  
• Gently tug the filter basket door towards you – the basket  
will first rotate and then slide out of the unit (Fig. 6).  
Fig. 10  
Fig. 11  
• Continue to slide the basket and remove from the filter  
swing arm (Fig. 7).  
• Take the IFDfilter out of the filter basket and clean the  
filter (Fig. 8).  
To clean the IFDfilter:  
• After removing the IFDFilter from the air purifier, gently  
run a vacuum cleaner with a nozzle or brush attachment along the filter to pick-up tiny particles (Fig. 9).  
Repeat on both sides.  
If your IFDfilter appears to have dirt that has not been removed by vacuuming, please follow the steps  
below to wash the IFDfilter.  
• Turn the power off and unplug the air purifier.  
• Remove the IFDfilter from the unit.  
• Fill the sink with lukewarm water and add a few drops of mild dish soap (Fig. 10).  
• Gently swish the filter in the soap solution to clean.  
• Soak the filter for 2-3 minutes. Do not leave for an extended period of time.  
• Rinse the filter with clean tap water.  
• Shake the filter to remove any excess water (Fig. 11).  
• Place the filter with the honeycomb side down on a plush towel.  
Note that the filter may still be discolored even after washing.  
This is acceptable and will not affect performance.  
• Allow the IFDfilter to dry for a few hours or overnight.  
• When the IFDfilter is completely dry, place back into the air purifier.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
HFD-135 OM English.qxd 10/14/05 5:35 PM Page 5  
REMOVING / CLEANING THE IFDFILTER (CONTINUED)  
CAUTION:  
Never place a wet IFDfilter in your air purifier.  
• The IFDFilter is NOT dishwasher safe. Do not place the IFDfilter in a dishwasher or subject it to  
other extreme hot water conditions.  
• Do not use any solvents, strong cleaning agents or flammable liquids to clean the IFDfilter.  
Resetting the Filter Clean Indicator  
After cleaning the IFDfilter, you need to reset the filter monitor.  
• Once the IFDfilter has been checked and cleaned, the filter monitor will need to be reset.  
• With the air purifier unit powered on, press and hold the filter reset button for approximately 10  
seconds or until the LCD display is clear.  
CLEANING THE PRE-FILTER  
The particle pre-filter helps pick-up large airborne particles that enter the filter. The pre-filter can be  
removed and rinsed by hand under warm water. Let the pre-filter dry completely before inserting it back  
into the unit.  
REPLACING THE ULTRAVIOLET (UV) LAMPS  
The UV Reset LED light will illuminate  
when it is time to replace the dual UV  
bulbs. “Replace UV Bulb” will also  
appear in the control panel.  
Fig. 13  
Fig. 14  
Fig. 12  
• Be sure to turn off and unplug your  
air purifier.  
• Remove the UV cover (Fig. 12).  
• Turn the UV bulb tab towards the unlock symbol (  
(Fig. 13).  
)
Fig. 15  
• Gently grasp the top of the tab and pull the bulb cartridge  
straight out of the UV socket (Fig. 14). Do not touch the  
bulb directly with your hands.  
• Do the same for the other bulb and pull the bulb cartridge  
out of the UV socket.  
• Replace the left and right UV bulb sockets with new UV  
lamps (part number 135UV).  
• Discard old UV bulb cartridge(s) only at household hazardous waste collection sites.  
• Place UV cover back in to its place until it clicks in position.  
• Plug the air purifier back into an electrical socket and turn the air purifier on.  
• Press and hold the UV Reset button for 10 seconds to clear the red LED light and “Replace UV Bulb”  
message (Fig. 15).  
NOTE: Bulb and bulb housing are not intended for use with any other product or purpose.  
NOTE: This unit is equipped with a safety interlock. The unit will not operate while the UV cover is  
removed.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
HFD-135 OM English.qxd 10/14/05 5:35 PM Page 6  
INSTALLING THE FILTERS  
Fig. 16  
Please make certain that the unit is OFF and unplugged.  
To install the IFDFilter and pre-filter:  
IFDFilter  
• Insert the pre-filter into the basket first.  
• Place the IFDfilter on top of the pre-filter, making certain that the  
insert arrows match up with the label outside the basket (Fig. 16).  
Pre-filter  
Cartridge  
• Slide the filter basket onto the swing arm and gently push the filter  
basket into the air purifier until it clicks into place.  
• Replace the rear panel door by lining up the tabs on the  
Fig. 17  
Rear  
Door  
bottom portion of the door with the notches on the air  
purifier and then turning the locking knob clockwise  
(Fig. 17).  
• Turn the locking knob clockwise to lock in place  
(Fig. 18).  
IFDFilter  
NOTE: This unit is equipped with a safety interlock. The  
unit will not operate while the Rear Door is removed.  
Notches  
Fig. 18  
CLEANING AND MAINTENANCE  
• Use a clean, dry cloth to wipe the external surfaces of the air purifier. DO NOT USE WATER, GASOLINE,  
POLISH, OR ANY CHEMICAL SOLUTION.  
• The IFDfilter and pre-filter should be cleaned at least once a month, or sooner depending on the air  
quality of the room (See “Removing/Cleaning the IFDFilter” or “Cleaning the Pre-Filter” respectively).  
FREQUENTLY ASKED QUESTIONS  
How often is cleaning required?  
The IFDfilter reset light will illuminate to indicate that the IFDfilter should be cleaned. We  
recommend cleaning the filter about once a month depending on the air quality of the room.  
I just cleaned my filter but the filter indicator bar is still showing it is dirty, what’s wrong?  
Each time you clean your filter you must reset the filter life indicator. It is a timer driven indicator to be  
used as a guideline, but does not represent the actual amount of dirt in the IFDfilter. Press and hold  
the appropriate button for up to 10 seconds and when you let go, the filter indicator bar should be  
reset.  
The filter indicator bar on my unit is completely full but my filter doesn’t really look dirty.  
The filter indicator on your unit is timer-based and does not measure the amount of particles in the  
IFDfilter. It is possible that your filter indicator could indicate that the filter is dirty but some particles  
are so small that they cannot be seen but are present in the filter. We recommend cleaning the IFD™  
filter (see Removing/Cleaning the IFDFilter in the manual).  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
HFD-135 OM English.qxd 10/14/05 5:35 PM Page 7  
FREQUENTLY ASKED QUESTIONS (CONTINUED)  
My filter bar says my filter is still relatively clean but when I checked my filter it was really dirty.  
In conditions where smoke, pets or air with a lot of contaminants are present it is possible that the filter  
could be dirty sooner than indicated on the indicator. The filter life indicator on your unit runs on a  
timer and if there are more particles in your air than in an average home, your filter could capture  
airborne particles sooner than indicated on the display. The indicator is intended to be used as a  
guideline and individual environmental conditions will vary.  
My unit will not turn on.  
The air purifier has a safety feature to ensure that all the covers are in place. The rear cover or the UV  
cover may not be installed correctly. Check to make sure the rear cover is installed flush with the unit  
and is locked. Check that the UV cover is flush with the unit and is snapped into place.  
When do the UV bulbs need to be replaced?  
The “Replace UV Bulb” message and light will turn on after 6 months of continuous use, so the bulbs  
should be replaced at this time.  
Is the IFDAir Purifier considered an ozone generator?  
No. Ozone generators produce large amounts of ozone and the EPA considers these unsafe for  
household use.  
REPLACEMENT FILTERS / UV BULBS  
To order a replacement pre-filter for the IFDAir Purifier model HFD-135, visit our website at  
www.kaz.com or call us at 1-800-477-0457.  
Washable Pre-Filter #60007: $6.25  
Replacement UV bulbs (2-pack), model number 135UV: $44.99  
IMPORTANT NOTE  
The ionizing process used by the air purifier produces small amounts of ozone as a byproduct. The air  
purifier complies with U.S. Government limits for acceptable levels of ozone (less than 50 parts per billion  
by volume of air circulating through the product). People with a history of respiratory problems or  
heart/lung disease should consult a physician prior to using this product.  
CONSUMER RELATIONS  
Mail questions or comments to:  
Kaz, Inc.  
Call us toll-free at: 1-800-477-0457  
Consumer Relations Dept.  
250 Turnpike Road  
Or visit our website at: www.kaz.com  
Southborough, MA 01772  
Please be sure to specify a model number.  
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE  
YOUR WARRANTY. DO NOT RETURN TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO  
OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE  
TO THE AIR PURIFIER OR PERSONAL INJURY.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
HFD-135 OM English.qxd 10/14/05 5:35 PM Page 8  
5 YEAR LIMITED WARRANTY  
YOU SHOULD FIRST READ ALL INSTRUCTIONS  
BEFORE ATTEMPTING TO USE THIS PRODUCT.  
C. This warranty does not cover the IFDfilter or  
pre-filter except for material or workmanship  
defects.  
A. This 5 year limited warranty applies to repair or  
replacement of product found to be defective in D. This warranty does not cover damage resulting  
material or workmanship. This warranty does  
not apply to damage resulting from  
commercial, abusive, unreasonable use or  
supplemental damage. Defects that are the  
result of normal wear and tear will not be  
considered manufacturing defects under this  
warranty.  
KAZ IS NOT LIABLE FOR INCIDENTAL OR  
CONSEQUENTIAL DAMAGES OF ANY NATURE.  
ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A  
PARTICULAR PURPOSE ON THIS PRODUCT IS  
LIMITED IN DURATION TO THE DURATION OF  
THIS WARRANTY.  
Some jurisdictions do not allow the exclusion or  
limitation of incidental or consequential  
damages or limitations on how long an implied  
warranty lasts, so the above limitations or  
exclusions may not apply to you. This warranty  
gives you specific legal rights, and you also  
may have other rights which vary from  
jurisdiction to jurisdiction. This warranty applies  
only to the original purchaser of this product  
from the original date of purchase.  
from any unauthorized attempts to repair or  
from any use not in accordance with the  
instruction manual.  
E. Return defective product to Kaz, Inc. with a  
brief description of the problem. Include proof  
of purchase and a $10 US/$15.50 CAN check  
or money order for handling, return packing  
and shipping charges. Please include your  
name, address and a daytime phone number.  
You must prepay shipping charges. Send to:  
In U.S.A.:  
Kaz, Inc.  
Attn: Returns Department  
4755 Southpoint Drive  
Memphis, TN 38118  
USA  
In Canada:  
Kaz, Inc.  
Attn: Returns Department  
510 Bronte Street South  
Milton, ON L9T 2X6  
Canada  
B. At its option, Kaz will repair or replace this  
product if it is found to be defective in material  
or workmanship. Defective product should be  
returned to the place of purchase in  
accordance with store policy. Thereafter, while  
within the warranty period defective product  
may be returned to Kaz.  
© 2005 Kaz, Incorporated. All Rights Reserved.  
P/N: 31IM0135190  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Texas Instruments Network Card TMS320TCI6486 User Manual
Toshiba CRT Television 14AF41 User Manual
Toshiba DVD VCR Combo SD V593SU User Manual
Toshiba Laptop A135 S2266 User Manual
TP Link Network Card TL PA201 User Manual
Transition Networks Network Card NFXEXXX01 User Manual
Tripp Lite Surge Protector iGuard User Manual
Tripp Lite Surge Protector SPS Series User Manual
Valcom Intercom System VSP V 2925A User Manual
Vivitar Digital Camera V69379M User Manual