Vermont Casting Indoor Fireplace BREF30 BREF36 BREF42 User Manual

INSTALLER/CONSUMER  
SAFETY INFORMATION  
PLEASE READ THIS MANUAL  
BEFORE INSTALLING AND  
USING APPLIANCE.  
Electric Fireplace  
Models:  
BREF30/36/42  
BREF30NH/36NH/42NH  
BREF36R/42R  
WARNING!  
IF THE INFORMATION IN THIS  
MANUAL IS NOT FOLLOWED  
EXACTLY, AN ELECTRICAL  
SHOCK OR FIRE MAY RESULT,  
CAUSING PROPERTY DAMAGE,  
PERSONAL INJURY OR LOSS  
OF LIFE.  
FOR YOUR SAFETY  
SERVICE MUST BE  
PERFORMED BY A QUALIFIED  
SERVICE AGENCY.  
DO NOT STORE OR USE  
GASOLINE OR OTHER  
FLAMMABLE VAPORS AND  
LIQUIDS IN THE VICINITY OF  
THIS OR ANY OTHER  
APPLIANCE.  
Homeowner's Installation &  
Operating Manual  
C
US  
CFM Specialty Home Products  
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777  
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER  
10004758 11/05 Rev. 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
Installation Instructions  
16. Disconnect all power coming to fireplace at main  
service panel before performing any cleaning or  
maintenance.  
General Information  
1. Read all instructions before using this appliance.  
17. Do not install this fireplace on carpet or vinyl floors,  
as discoloration may occur.  
18. SAVE THESE INSTRUCTIONS.  
2. This appliance is hot when in use. To avoid burns, do  
not let bare skin touch hot surfaces. If provided, use  
handles when moving this appliance. Keep combus-  
tible materials, such as furniture, pillows, bedding,  
papers, clothes and curtains at least  
3 feet (1 m) from the front of this appliance.  
CAUTION: Extreme caution is necessary  
when any heater is used by or near chil-  
dren or invalids, and whenever the heater  
is left operating and unattended.  
Wiring  
Ensure the power conversion/switch (if  
equipped) is in the proper position for re-  
quired supply voltage prior to connecting  
the unit to power supply.  
3. Do not operate any heater if the appliance malfunc-  
tions, or if it has been dropped or damaged in any  
manner.  
4. Any repairs to this fireplace should be carried out by  
a qualified service person.  
5. Under no circumstances should this fireplace be  
modified. Parts having to be removed for servicing  
must be replaced prior to operating this fireplace  
again.  
Do not use this fireplace if any part of it  
has been under water. Immediately call a  
qualified service technician to inspect the  
fireplace and replace any part of the elec-  
trical system that has been under water.  
A qualified electrician must perform any  
electrical wiring of this appliance. This wir-  
ing must be done in accordance with local  
codes, and/or in Canada, with the current  
CSA C22.1 Canadian Electrical code; for  
U.S.A. installation, National Electrical Code  
ANSI/NFPA No. 70.  
6. Do not use outdoors.  
7. This heater is not intended for use in bathrooms,  
laundry areas and similar indoor locations. Never  
locate this appliance where it may fall into a bathtub  
or other water container.  
8. This appliance, when installed, must be electrically  
grounded in accordance with local codes, or, in the  
absence of local codes, with the current CSA C22.1  
Canadian Electrical Code; for U.S.A. installations,  
follow local codes and the National Electrical Code,  
ANSI/NFPA NO. 70.  
NOTES: The unit is shipped from the factory config-  
ured for 120 Volt operation.  
Ensure the power conversion switch is in the  
proper position for the required supply voltage.  
All wiring must be completed prior to installing the  
unit.  
9. Do not insert or allow foreign objects to enter any  
ventilation or exhaust opening, as this may cause an  
electric shock or fire, or damage the appliance.  
Electrical Connection  
10. To prevent a possible fire, do not block air intake or  
exhaust in any manner. Do not use on soft surfaces  
(e.g., beds) where openings may become blocked.  
11. This appliance has hot and arcing or sparking parts  
inside. Do not use it in areas where gasoline, paint or  
flammable liquids are used or stored. This fireplace  
should not be used as a drying rack for clothing, nor  
should Christmas stockings or decorations be hung  
in the area of it.  
12. Use this appliance only as described in this manual.  
Any other use not recommended by the manufactur-  
er may cause fire, electric shock or injury to persons.  
13. Do not burn wood or other materials in this fireplace.  
14. Do not strike the fireplace glass.  
1. Loosen the screws securing junction box cover.  
2. Remove knockouts in the box cover to use a cable  
clamp.  
3. Place the unit in position in the opening. Level it with  
shims if necessary, and attach the unit to the frame  
using the nailing flanges provided.  
4. The unit is factory wired for 120 Volt power supply.  
If 208/240 Volt operation is required, flip the switch  
located on junction box and reconfigure the wiring  
as covered on page 7. Wires L1, L2, N, and G are  
located inside the junction box.  
5. Wire a dedicated, properly fused, 20 Amp rated  
circuit for appropriate voltage (120 or 208/240).  
6. Place all connectors inside junction box and replace  
the cover to ensure connections are tight.  
15. Always use a certified electrician for installation.  
10004758  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
Fireplace Dimensions  
Rough  
Opening  
Depth  
H
M
1/2" (13mm)  
5/8" (16mm)  
Recessed  
L
G
Nailing Flange  
O
K Rough Opening Width  
M
5/8" (16mm)  
Rough  
Opening  
Height  
N
E
D
J
B
F
C
3³⁄₄"  
(95mm)  
E
7²⁹⁄₃₂"  
(192mm)  
2¹¹⁄₃₂"  
A
(60mm)  
Fig. 1 Fireplace specifications and framing dimensions.  
Ref.  
A
BREF30/BREF30NH  
BREF36/BREF36NH/BREF36R  
BREF42/BREF42NH/BREF42R  
34”  
36”  
(864 mm)  
(914 mm)  
(762 mm)  
(533 mm)  
(191 mm)  
(502 mm)  
(356 mm)  
(698 mm)  
40"  
36"  
(1016mm)  
(914mm)  
(914mm)  
(533mm)  
(191mm)  
(502mm)  
(356mm)  
(698mm)  
45⁵⁷⁄₆₄"  
36"  
(1166mm)  
(914mm)  
(1067mm)  
(533mm)  
(191mm)  
(502mm)  
(406mm)  
(85mm)  
B
C
30”  
36"  
42"  
D
21”  
21"  
21"  
E
7¹⁄₂”  
19³⁄₄”  
14”  
7¹⁄₂"  
19³⁄₄"  
14"  
7¹⁄₂"  
F
19³⁄₄"  
16"  
G
H
27¹⁄₂”  
27¹⁄₂"  
31¹¹⁄₁₆"  
Framing Dimensions  
J
K
L
36¹⁄₂”  
35”  
(927 mm)  
(889 mm)  
(356 mm)  
(953 mm)  
(1372 mm)  
(686 mm)  
36¹⁄₂"  
41"  
(927mm)  
(1041mm)  
(356mm)  
(953mm)  
1372mm)  
(686mm)  
36¹⁄₂"  
46⁵⁷⁄₆₄"  
16"  
(927mm)  
(1191mm)  
(406mm)  
(1245mm)  
(1765mm)  
(895mm)  
14”  
14"  
M
N
O
37¹⁄₂”  
54”  
37¹⁄₂"  
54"  
49"  
69¹⁄₂"  
35¹⁄₄"  
27”  
27"  
Electrical Specifications  
Voltage:  
Total Amps:  
Total Watts:  
120 Volt  
120 Volt (NH)  
2 Amps  
240 Volt  
13 Amps  
12.9 Amps  
3100 Watts  
2855 Watts  
1550 Watts  
1455 Watts  
240 Watts  
N/A  
Heater Rating:  
4
10004758  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
Mantels  
The height that a combustible mantel is fitted above the  
fireplace is dependent on the depth of the mantel. This  
also applies to the distance between the mantel leg (if  
fitted) and the fireplace.  
For correct mounting height and width, refer to Figure  
2a and 2b.  
J
I
The distances and reference points are not affected by  
the fitting of a bay window front trim kit.  
H
G
F
Noncombustible mantels and legs may be installed at  
any height and width around the appliance.  
Black  
Surround  
Face  
Mantel Leg  
When using paint or lacquer to finish the mantel, such  
paint or lacquer must be heat-resistant to prevent dis-  
coloration.  
CFM164a  
K
L
M
Side of Combustion  
Chamber  
N
O
Mantel Clearances  
V
W
X
Y
Wall  
Z
CFM170  
Mantel  
Leg Depth  
Mantel Leg from Side  
of Comb. Opening  
Ref.  
Ref.  
A
B
C
D
E
F
G
H
I
14" (356 mm)  
12" (305 mm)  
10" (254 mm)  
8" (203 mm)  
1¹⁄₂" (38 mm)  
K
L
M
N
O
14" (356 mm)  
12" (305 mm)  
10" (254 mm)  
8" (203 mm)  
1¹⁄₂" (38 mm)  
J
Fig. 2b Combustible mantel leg minimum installation.  
Framing  
Top of Combustion  
Chamber  
CFM146b  
1. Choose fireplace location.  
2. Place fireplace into position.  
3. Frame in the fireplace with a header across the top.  
It is important to allow for finished face when setting  
the depth of the frame.  
Mantel Shelf  
Depth  
14" (356 mm)  
12" (305 mm)  
10" (254 mm)  
8" (203 mm)  
1¹⁄₂" (38 mm)  
Mantel from Top  
of Comb. Chamber  
Ref.  
Ref.  
V
W
X
Y
Z
A
B
C
D
E
25" (635 mm)  
23" (584 mm)  
21" (533 mm)  
19" (483 mm)  
15" (381 mm)  
Four (4) nailing flanges are supplied with the fireplace  
(found on the fireplace hearth). To level the box and  
secure it firmly in place, remove the nailing flanges from  
the hearth and install at the sides of the fireplace as  
shown in Figure 3.  
Fig. 2a Combustible mantel minimum installation.  
10004758  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
Hearth  
A hearth is not mandatory; however, for aesthetic pur-  
poses, we recommend use of a noncombustible hearth  
that does not obstruct the air openings.  
Cold Climate Installation: To conform to  
applicable insulation codes, it is manda-  
tory the outer walls be insulated when  
installing this unit against a non-insulated  
exterior wall or chase.  
Nail  
side-nailing  
flange  
Cabinet Installations  
FP549  
Cabinets are available from your dealer which allow  
fast, convenient installation of your fireplace against  
existing walls.  
Fig. 3 Adjustable drywall strip (nailing flange).  
Finishing  
Main Power Wall Switch Wiring  
CAUTION: All joints between the finished  
wall and the appliance surround (top and  
sides) may be sealed only with noncom-  
bustible material. Only noncombustible  
material can be applied as facing to  
the appliance surround (the black painted  
face).  
To reduce the risk of fire, electrical shock,  
and personal injury, before attempting  
maintenance or service, disconnect all  
power to the fireplace  
at the main service panel.  
120 Volt Wall Switch Wiring Installation  
A qualified electrician must perform any  
electrical wiring of this appliance. For Ca-  
nadian installations, wiring must be done  
in accordance with local codes, and/or  
the current CSA C22.1 Canadian Electrical  
Code. For U.S.A. installations, wiring must  
be done in accordance with the National  
Electrical Code ANSI/NFPA No. 70.  
When finishing the appliance, never obstruct or  
modify the air inlet/outlet grilles in any manner.  
NOTE: Finish the wall with the material of your  
choice. Refer to Figures 2a and 2b for specific  
clearances when installing a combustible mantel or  
other combustible projection.  
Locating your Electric Fireplace  
NOTE: For 120 Volt installations, use a  
Your new fireplace may be installed into an existing  
masonry or zero-clearance fireplace. It may also be in-  
stalled using a prefabricated cabinet available from your  
dealer, or be built into a wall.  
single-pole, single-throw, 20 Amp-rated wall switch.  
(NH models do not require the 20 Amp switch. A  
regular 15 Amp wall switch may be used.)  
Wiring of the wall switch must be completed prior  
to installing the unit.  
When choosing a location for your new fireplace, en-  
sure that the general instructions are followed. Also, for  
best effect, install the fireplace out of direct sunlight.  
Connect the wall-mounted switch to the fireplace by  
running grounded 2-conductor wire (Min.14 AWG) to  
the switch from the junction box on the side of the unit.  
Clearance to Combustibles  
1. Locate the voltage selection switch under the logset  
on the left front corner of the unit. (Not applicable to  
NH models)  
2. Ensure the switch is in the 120 Volt position. (Not  
applicable to NH models.)  
Sides ......................................................... 0" (0 mm)  
Floor.......................................................... 0" (0 mm)  
Top ........................................................... 0" (0 mm)  
3. Loosen the screws securing the junction box cover,  
and remove the cover.  
4. Remove knockouts in the box cover to use a cable  
clamp.  
5. Pull out two (2) wires: black and white.  
6. Connect the hot wire (black) from the wall switch to  
the L1 (black) wire on the unit, and the other wire  
from the wall switch to the L1 (black) wire on the  
power supply.  
6
10004758  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
120/240 Volt Wall-Mounted  
7. Connect the white wire from the unit to the neutral  
(white) wire on the power supply.  
8. Connect the ground wire from the wall switch to the  
wire grouping from the power supply and the ground  
stud in the junction box.  
9. Make sure the red wire (L2) in the junction box has a  
closed end splice or a wire nut properly applied.  
10.Ensure all connections are tight. Insert all wiring  
inside the junction box and secure the cover.  
Thermostat Wiring  
Before attempting maintenance or ser-  
vice—to reduce risk of fire, electrical  
shock and personal injury—disconnect all  
power to the fireplace at the main service  
panel.  
NOTE: Wiring of the wall thermostat must be com-  
pleted prior to the installation of the unit.  
240 Volt Wall Switch Wiring Installation  
Use a single pole thermostat rated for 120/240 Volt  
operation.  
A qualified electrician must perform any  
electrical wiring of this appliance. For  
Canadian installation, wiring must be done  
in accordance with local codes, and/or  
the current CSA C22.1 Canadian Electrical  
Code. For U.S.A. installation, wiring must  
be done in accordance with the National  
Electrical Code ANSI/NFPA No. 70.  
When installing the wall thermostat, make sure to  
turn the heater control inside fireplace all the way  
clockwise to the highest set point temperature.  
Connect the wall-mounted thermostat to the fireplace  
by running a grounded 2-conductor wire (min. 14 AWG)  
to the thermostat from the junction box on the side of  
the unit.  
1. Loosen the screws securing the junction box cover  
and remove the cover.  
NOTE: For 240 Volt installations, use a double-pole,  
single-throw, 20 Amp, 240V rated wall switch.  
2. Remove knockouts in the box cover to use a cable  
clamp.  
Wiring of the wall switch must be completed prior  
to installing the unit.  
3. Pull out the two (2) brown wires with the closed end  
splice at the end.  
4. Cut off the closed end splice, separate the two wires,  
and strip approximately 5/8" (15mm).  
5. Connect one (1) wire from the thermostat to one (1)  
of the brown wires; connect the other wire from the  
thermostat to the other brown wire.  
Connect the wall-mounted switch to the fireplace by  
running grounded 3-conductor wire (MIN. 14 AWG) to  
the switch from the junction box on the side of the unit.  
1. Locate the voltage selection switch under the logset  
on the left front corner of the unit.  
2. Move the switch from the 120 Volt to the 240 Volt  
position.  
6. Connect the ground wire from the wall thermostat to  
the power supply wire group and the ground stud in  
the junction box.  
7. Ensure all connections are tight. Insert all wiring into  
the junction box and secure the cover.  
3. Loosen the screws securing the junction box cover,  
and remove the cover.  
4. Remove knockouts in the box cover to use a cable  
clamp.  
5. Pull out three (3) wires: black, red, and white.  
6. Connect one (1) wire (black) from the wall switch to  
the L1 (black) wire on the unit, and the other wire  
from the wall switch to the L1 (black) wire on the  
power supply.  
Installation Cautions  
Make sure the power is turned OFF before  
proceeding.  
7. Connect one (1) of the wires from the wall switch to  
the L2 (red) wire on the unit, and the other wire from  
the wall switch to the L2 (red) wire on the power sup-  
ply.  
If repairing or replacing any electrical com-  
ponent or wiring, the original wire routing,  
color coding and securing locations must  
be followed.  
8. Connect the white wire from the unit to the neutral  
(white) wire on the power supply.  
9. Connect the ground wire from the wall switch to the  
wire grouping from the power supply and ground  
stud in the junction box.  
Any electrical repairs or rewiring of this  
unit should be carried out by a licensed  
electrician in accordance with national and  
local codes.  
10. Ensure all connections are tight. Insert all wiring  
inside the junction box and secure the cover.  
10004758  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
120 Volt Unit Installation  
5. Pull out three (3) wires: black, red, and white.  
6. The unit is shipped from factory with a closed end  
splice on the red wire. Cut off this splice and strip  
approximately 5/8" (15mm) wire sheathing.  
1. Locate the switch under the logset on the left front  
corner of the unit.  
7. Connect the black wire from the unit to the L1  
(black) from the power supply. Connect the red wire  
from the unit to the L2 (red) from the power supply.  
Connect the white wire from the unit to the neutral  
(white) from the power supply.  
NOTE: Wiring must be connected to a 20 Amp  
dedicated circuit breaker or fuse in the electrical  
panel of the dwelling.  
2. Check the voltage selection switch position to ensure  
it is in the 120 Volt position.  
3. Loosen the screws securing the junction box cover  
and remove the cover.  
4. Remove knockouts in the box cover to use the cable  
clamp.  
5. Pull out two (2) wires: black and white.  
6. Connect the black wire from the unit to the L1 (black)  
from the power supply. Connect the white wire from  
the unit to the neutral (white) from the power supply.  
NOTE: Wiring must be connected to a 20 Amp  
dedicated circuit breaker or fuse in the electrical  
panel of the dwelling.  
7. Connect the ground wire from the power supply to  
ground stud in the junction box.  
8. Make sure the red wire (L2) in the junction box has a  
closed end splice or a wire nut properly applied.  
8. Connect the ground wire from the power supply to  
ground stud in the junction box.  
9. When the unit has been configured for the appropri-  
ate power supply voltage, ensure all connections  
are tight. Insert all wiring inside the junction box and  
secure the cover.  
10. Turn the power to the unit on at the breaker/fuse  
panel. Place the unit into operation and check to  
make sure the whole system is operating properly.  
9. When the unit has been configured for the appropri-  
ate power supply voltage, ensure all connections  
are tight. Insert all wiring inside the junction box and  
secure the cover.  
10. Turn the power to the unit on at the breaker/fuse  
panel. Place the unit into operation and check to  
make sure the whole system is operating properly.  
Resetting the  
Temperature Cutout Switch  
To reduce the risk of fire, electrical shock,  
and personal injury, before attempting  
maintenance or service, disconnect all  
power to the fireplace at the main service  
panel.  
120 Volt (NH) Unit Installation  
NOTE:The heater on this fireplace is protected with  
a safety limit device to prevent overheating. Should  
the heater overheat, an automatic cutout turns the  
heater OFF; it will not come back ON without being  
manually reset.  
1. Loosen the screws securing the junction box cover  
and remove the cover.  
2. Remove knockouts in the box cover to use the cable  
clamp.  
The safety limit device is located in a cutout at the right  
front top corner by the cover fan/heater. To reset the  
switch, insert a small flat screwdriver into this cutout  
and push the reset button on the safety limit device.  
3. Pull out two (2) wires: black and white.  
4. Connect the black wire from the unit to the L1 (black)  
from the power supply. Connect the white wire form  
the unit to the neutral (white) form the power supply.  
5. Connect the ground wire from the power supply to  
the ground stud in the junction box.  
6. Ensure all connections are tight. Insert all wiring  
inside the junction box and secure the cover.  
Safety Limit Device  
7. Turn the power to the unit on at the breaker/fuse  
panel. Place the unit into operation and check to  
make sure the system is operating properly.  
Cover Fan/  
Heater  
240 Volt Unit Installation  
1. Locate the voltage selection switch under the logset  
on the left front corner of the unit.  
Small Flat Screwdriver  
FP1452  
2. Check the switch position to ensure it is in the  
240 Volt position.  
Fig. 4 Reset the switch with a small flat screwdriver.  
3. Loosen the screws securing the junction box cover  
and remove the cover.  
4. Remove knockouts in the box cover to use the cable  
clamp.  
8
10004758  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
Screen Kit Installation  
1. Remove the plastic bag from each screen.  
(Clip)  
2. Remove the four (4) metal clips, two (2) for each  
side of the fireplace opening.  
3. Slide screen panels against sides of the fireplace  
opening.  
4. Align each metal clip with the hole it was removed  
from, while at the same time, hooking the clip  
through the last wire of the screen. Snap clips into  
place. (Fig. 5)  
5. Pull screens back and forth to ensure they work  
freely.  
FP1041  
Fig. 5 Clip installation.  
Service Instructions  
To reduce the risk of fire, electrical shock  
B111  
B114  
or personal injury, disconnect all power  
coming to the fireplace at the main service  
panel before attempting any maintenance  
or cleaning.  
Maintenance of Motor  
The motors used on the fan and the drum assemblies  
are pre-lubricated for extended bearing life, and require  
no further lubrication. However, periodic cleaning/vacu-  
uming of the fan/heater is recommended.  
B113  
B112  
LG241  
Fig. 6 BREF/BREF36R ceramic log set placement.  
Installation of BREF36/BREF36R  
with Ceramic Log Set  
Installation of BREF42/BREF42R  
with Ceramic Log Set  
1. Turn OFF power to the unit at the main service  
panel.  
1. Turn OFF power to the unit at the main service  
panel.  
2. Open glass (if applicable); open the steel curtain.  
3. Remove logs from packaging.  
2. Open glass (if applicable); open the steel curtain.  
3. Remove logs from packaging.  
NOTE: The ember lava rock is shipped in place;  
no adjustment is necessary.  
NOTE: The ember lava rock is shipped in place;  
no adjustment is necessary.  
4. Fit the right log (B111) onto the plate log support.  
Ensure the bottom holes of B111 are located on the  
two pins of the support.  
4. Place the front center log (G3) on the ember lava  
rock. Use the notches under the center front of the  
log to properly locate the log.  
5. Place the center log (B112) on the ember lava rock.  
Use the notches under the center portion of B112 to  
locate it properly.  
5. Fit the right rear log (G1) on the place support. En-  
sure the bottom holes of G1 are located on the two  
(2) pins of the support; rest the other end of G1 on  
the top back of G3.  
6. Place the bottom left log (B113) into position by rest-  
ing the hole under the center of B113 over the knob  
on center top of B112. The other end of B113 rests  
against the back wall of the plate log support.  
6. Fit the left rear log (G2) on the place support. Ensure  
the bottom holes of G2 are located on the two (2)  
pins of the support.  
7. Fit the top left log (B114) onto the plate log support.  
Ensure the bottom holes of B114 are located on  
the two (2) pins of the support; rest the other end of  
B114 on the top back of B113.  
7. Place the front left log (G4) in position by resting the  
front left back log on the top right log rear left (G2).  
The front of this log will rest against the back wall of  
the log support plate.  
10004758  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
8. Place the right front log (G5) in position on the  
ember lava rock. Use the notches under the log front  
right to have a proper location.  
Cleaning Trim  
Clean the trim using a soft cloth you have slightly damp-  
ened with lemon oil; then buff with a clean soft cloth.  
G2  
G1  
NOTE: You can obtain lemon oil at super-markets  
and hardware stores. Do not use commercially  
made brass polish or household cleaners, as these  
products will damage the trim.  
G5  
G3  
LG324  
G4  
Fig. 7 BREF42/BREF42R ceramic log placement.  
To reduce the risk of fire, electrical shock  
or personal injury, disconnect all power  
coming to the fireplace at the main service  
panel before attempting any maintenance  
or cleaning.  
Replacing Light Bulbs  
This fireplace uses four (4) clear, 120 Volt, 60 Watt,  
E-12 socket base (small base, chandelier candle-type)  
light bulbs. These lights are located under the ember  
bed of the unit.  
Do not exceed 60 Watts per bulb. Use of  
higher-rated bulbs may result in fire, caus-  
ing property damage, personal injury, or  
loss of life.  
NOTE: For the sake of convenience, you may wish  
to consider replacing all the light bulbs if one of  
them burns out.  
1. Turn OFF the power to the unit at the main service  
panel.  
2. If the fireplace has been operating, allow it to cool.  
3. Open glass (if applicable); open steel curtain.  
4. Remove the log. Remove the two (2) screws, one  
on each side of the ember bed/plate support log set  
down. Remove the ember bed/plate support log set.  
5. Examine the bulbs to determine which one(s) need  
to be replaced (if you are not going to replace all).  
7. Install new light bulb(s) by screwing in while holding  
the socket.  
8. Reinstall the ember bed, log set, glass door, and  
steel curtain.  
10  
10004758  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
Electrical Wiring Diagram without Integral Remote Control  
For Units with Ceramic Log Sets (Refer to Figures 6 & 7)  
G
1 WHITE  
REAR  
1
FRONT  
9 RED  
2 WHITE  
14 BLACK  
22 WHITE  
11 RED  
14 BLACK  
15  
4
FAN/HEATER  
MOTOR  
5
2
13 BLACK  
L1  
4 BLACK  
T'S  
3
6
2
13  
5 RED  
3
4
12 BROWN  
5
12 BROWN  
COIL  
20 WHITE  
19 WHITE  
6
1b  
2b  
2
17 WHITE  
1
9
FLAME  
MOTOR  
8 BLACK  
1a  
2a  
8
13  
7 BLACK  
L2  
BLACK  
WHITE  
16 WHITE  
6 BLACK  
BLACK  
WHITE  
12  
N
21 WHITE  
15 WHITE  
7
11  
10  
Component Identification  
1. Heater Element  
2. Limit Control, 175/20 DIF  
3. Relay Switch, 120V 50/60Hz  
4. Fan/Heater Motor  
5. Thermostat  
8. Flame Motor  
9. Light Bulb  
10. Light Socket w/Wiring Assembly  
11. Cable Tie, Nylon 6" - 1¹⁄₂" Black  
12. Bushing Snap, Split 1"  
6. Switch, Rocker  
7. Switch  
13. Closed End Splice, 2/18 Ga.Wire  
14. CFM Wire  
15. Sensor, 230°F, Manual Reset  
FP1449  
Fig. 8 Wiring Diagram for units with ceramic log set. (Refer to Figure 6 & 7)  
10004758  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
Electrical Wiring Diagram with Integral Remote Control  
For Units with Ceramic Log Sets (Refer to Figures 6 & 7)  
G
1 WHITE  
REAR  
1
FRONT  
11 RED  
2 WHITE  
16 BLACK  
13 RED  
22 WHITE  
16 BLACK  
4
15  
4 BLACK  
L1  
FAN/HEATER  
MOTOR  
2
15 BLACK  
5
T'S  
1
3
6
2
5
6 RED  
3
14 BROWN  
4
14 BROWN  
12  
COIL  
21 WHITE  
24 WHITE  
19 WHITE  
8
2b  
2
1b  
1
9
FLAME  
MOTOR  
7
13  
13  
9 BLACK  
6
2a  
1a  
8 BLACK  
3 BLACK  
BLACK  
WHITE  
L2  
25 RED  
10 BLACK  
18 WHITE  
N
23 WHITE  
BLACK  
WHITE  
7 BLACK  
IN  
N
OUT IN  
OUT  
L
N
L
17 WHITE  
16  
11  
10  
Component Identification  
1. Heater Element  
2. Limit Control, 175/20 DIF  
9. Light Bulb  
10. Light Socket w/Wiring Assembly  
3. Relay Switch, 120V, 50/60Hz 11. Cable Tie Nylon 6"-1¹⁄₂" Black  
4. Fan/Heater Motor  
5. Thermostat  
6. Switch, Rocker  
7. Switch  
12. Bushing Snap, Split 1"  
13. Closed End Splice 2/18 Ga.Wire  
14. CFM Wire  
15. Sensor, 230°F Manual Reset  
16. Receiver  
FP1450  
8. Flame Motor  
Fig. 9 Wiring Diagram for units with ceramic log set. (Refer to Figures 6 & 7) BREF36R/BREF42R  
12  
10004758  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
Electrical Wiring Diagram with Heater and Integral Remote Control  
G
1 WHITE  
REAR  
1
FRONT  
11 RED  
4
2 WHITE  
16 BLACK  
13 RED  
22 WHITE  
16 BLACK  
2
15  
4 BLACK  
L1  
FAN/HEATER  
MOTOR  
15 BLACK  
5
T'S  
1
3
6
2
6 RED  
3
14 BROWN  
4
5
14 BROWN  
21 WHITE  
12  
16  
COIL  
24 WHITE  
19 WHITE  
3
1b  
1
2b  
2
9
7
FLAME  
MOTOR  
9 BLACK  
2a  
1a  
13  
8 BLACK  
18 WHITE  
3 BLACK  
10 BLACK  
BLACK  
WHITE  
L2  
N
25 RED  
23 WHITE  
7 BLACK  
BLACK  
17 WHITE  
WHITE  
17  
10  
IN  
N
OUT IN OUT  
L
L
N
Component Identification  
1. Heater Element  
2. Limit Control, 175/20 DIF  
3. Relay Switching, 120V, 50/60Hz  
4. Fan/Heater Motor  
5. Thermostat  
9. Light Bulb  
10. Light Socket w/Wiring Assembly  
12. Bushing Snap, Split 1"  
13. Closed End Splice 2/18 Ga. Wire  
14. CFM Wire Req'd BREF36  
15. Sensor, 230°F Manual Reset  
6. Switch, Rocker  
7. Switch  
8. Flame Motor  
16. Closed End Splice 3/4" 18GA Wire  
17. Receiver  
FP1541  
Fig. 10 Wiring diagram for models with heat.  
10004758  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
Electrical Wiring Diagram without Heater and Integral Remote Control  
G
2
7 WHITE  
MOTOR  
FLAME  
3
1
3
2
N
8 WHITE  
4 BLACK  
O
I
1
3 BLACK  
6 WHITE  
L1  
1 BLACK  
BLACK  
WHITE  
BLACK  
WHITE  
2 BLACK  
5 WHITE  
4
CFM Component Identification  
1. Switch  
2. Flame Motor  
3. Light Bulb  
4. Light Socket w/Wiring Assembly  
6. CFM Wire req'd  
FP1540  
Fig. 14 Wiring diagram for models without heat. (BREF30NH/BREF36NH/BREF42NH)  
14  
10004758  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
Operating Instructions  
For units with ceramic log sets. (Figs. 6 & 7)  
3. Relearn  
This set of instructions applies to units with ceramic log  
sets. (Figs. 6 & 7) The control compartment is located  
inside the fireplace behind the steel curtain near the  
left front corner. To access the controls, simply slide the  
steel curtain open.  
The BREF36R and BREF42R fireplaces with integral  
remote control have pre-programmed, matched-pair  
receiver/transmitters already set with randomly selected  
house codes. It is highly unlikely that the fireplace code  
will ever need to be relearned. If the fireplace needs to  
relearn receiver/transmitter house codes, perform the  
following steps:  
Control Panel  
1. ON/OFF Switch  
3. Learn  
1. Be sure there is power to the fireplace.  
2. Be sure there is a good battery in the transmitter  
(hand-held remote).  
3. Open the battery compartment of the remote.  
4. Press and release the small button located in the top  
left corner. This will randomly select a new house  
code in the remote transmitter.  
5. Close the remote transmitter battery compartment.  
2. Heater Control  
FP1451a  
4. ON/OFF  
6. Press either the ON or OFF button on the remote  
transmitter, and the Learn button on the fireplace at  
the same time. The fireplace is now ready to accept  
commands from the remote transmitter.  
Fig. 12 Control panel.  
1. ON/OFF Switch  
The ON/OFF switch is for supplying power to light ef-  
fects of the fireplace. This switch is normally illuminated  
to indicate there is electrical power to the unit.  
4. ON/OFF  
The ON/OFF button on the fireplace (below the Learn  
button) is to turn the fireplace ON and OFF when the  
battery in remote transmitter is weak, or to manually  
operate the fireplace without the remote transmitter.  
NOTE: The device complies with Part 15 of the FCC  
Rules. Operation is subject to the following two  
condition:  
1. This device may not cause harmful interference,  
and  
2. This device must accept any interference re-  
ceived, including interferences that may cause  
undesired operation.  
2. Heater Control  
The heater control acts to turn the heater ON and OFF,  
as well as setting the comfort level in the room.  
Turn the knob clockwise form the "OFF" position to  
place the heater into operation. The further the knob is  
rotated clockwise, the higher the set point temperature.  
Turn the knob counterclockwise to lower the set point  
temperature. Turn it all the way counterclockwise to turn  
the heater function OFF.  
10004758  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
Operating Instructions  
For all other units.  
2. Heater Control  
The control compartment is located inside the fireplace  
behind the steel curtain near the left front corner. To ac-  
cess the controls, simply slide the steel curtain open.  
The heater control acts to turn the heater ON and OFF,  
as well as setting the comfort level in the room.  
Turn the knob clockwise from the "OFF" position to  
place the heater into operation. The further the knob is  
rotated clockwise, the higher the set point temperature.  
Control Panel  
1. ON/OFF Switch  
Turn the knob counterclockwise to lower the set point  
temperature. Turn it all the way counterclockwise to turn  
the heater function OFF.  
3. Remote Control  
If the unit is equipped with an on/off remote control, this  
feature is to turn the flame effect on and off remotely  
while the switch on the control panel is off. If the control  
panel switch is on, this bypasses the remote control.  
The receiver and transmitter is a matched-pair that  
is pre-programmed and must be replaced together, if  
necessary.  
FP1451  
2. Heater Control  
Fig. 13 Control panel.  
1. ON/OFF Switch  
NOTE: The device complies with Part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions:  
The ON/OFF switch is for supplying power to light ef-  
fects of the fireplace. This switch is normally illuminated  
to indicate that there is electrical power to the unit.  
1. This device may not cause harmful interference,  
and  
2. This device must accept any interference re-  
ceived, including interference that may cause  
undesired operation.  
16  
10004758  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
BREF36/BREF36R  
BREF42/BREF42R  
1d  
1a  
 
 
 
 
1c  
1b  
 
5
4
3
2
8
7
10  
6
12  
15  
13  
16  
18  
14  
17  
CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products  
at any time, without notice.  
BREF36/42, BREF36R/42R Electric Fireplace  
for Units with Ceramic Log Sets  
10004758  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
BREF36/42, BREF36R/42R Electric Fireplace  
for Units with Ceramic Log Sets (continued)  
Ref. Description  
1. Log Set Complete  
BREF36  
10004797  
BREF36R  
10004797  
BREF42  
10004950  
BREF42R  
10004950  
1a. Log  
1b. Log  
1c. Log  
1d. Log  
1e. Log  
2. Heater Element  
10004470 (B111) 10004470 (B111) 10004945 (G1)  
10004471 (B112) 10004471 (B112) 10004946 (G2)  
10004472 (B113) 10004472 (B113) 10004947 (G3)  
10004473 (B114) 10004473 (B114) 10004948 (G4)  
10004945 (G1)  
10004946 (G2)  
10004947 (G3)  
10004948 (G4)  
10004949 (G5)  
10004584  
--  
--  
10004949 (G5)  
10004584  
10004262  
10001393  
10002987  
10004695  
10004720  
10001639  
10004957  
10006386  
10006391  
10004958  
10004847  
10004853  
10003568  
10001172  
--  
10004584  
10004262  
10001393  
10002987  
10004695  
10004720  
10001639  
10004518  
10006386  
10006381  
10004517  
10003350  
10006380  
10003568  
10001172  
--  
10004584  
10004262  
10001393  
10002987  
10004695  
10004720  
10001639  
10004518  
10006389  
10006381  
10004517  
10003350  
10006380  
10003568  
10001172  
10005140  
10005141  
10006382  
3. Motor, AC, w/Terminals  
4. Rocker Switch (Illuminated)  
5. Thermostat - Heater Control  
6. Fan w/Bracket Assembly  
7. Sensor, 230°F Manual Reset  
8. Knob - Flame Speed, Heater Controls  
9. Light Filter - Ember Bed (Not shown)  
10. Plate Control Assembly  
11. Screen Tinted Plastic (Not shown)  
12. Ember Lava Rock  
13. Flame Generator Assembly  
14. Plate Log Support Assembly  
15. Socket Light Bulb Lower Assembly  
16. Limit Control, 175/20 DIF  
17. Transmitter  
10004262  
10001393  
10002987  
10004695  
10004720  
10001639  
10004957  
10006389  
10006391  
10004958  
10004847  
10004853  
10003568  
10001172  
10005140  
10005141  
18. Receiver  
19. CFM Wire Req'd (Not shown)  
--  
--  
10004851  
10004851  
10006382  
18  
10004758  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
BREF30/36, BREF30/36NH  
1
2
3
4
BREF42/BREF42NH  
1
5
8
7
9
6
11  
15  
13  
12  
16  
14  
22  
23  
21  
21  
 
17  
20  
CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products  
at any time, without notice.  
BREF30/36/42, BREF30NH/36NH/42NH Electric Fireplace  
10004758  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
BREF30/36/42, BREF30NH/36NH/42NH Electric Fireplace  
(continued)  
Ref. Description  
BREF30 BREF30NH BREF36 BREF36NH BREF42 BREF42NH  
1. Log Set Complete  
2. Heater Element  
10006532  
10004584  
10004262  
10001393  
10002987  
10004695  
10004720  
10001639  
10007610  
10007612  
10007461  
10003350  
10007434  
10007447  
10006453  
10001172  
10008487  
10008487  
10006382  
7554299  
10006532  
--  
10004262  
10001393  
--  
10006532  
10004584  
10004262  
10001393  
10002987  
10004695  
10004720  
10001639  
10007443  
10007430  
10007461  
10003350  
10007434  
10007447  
10006453  
10001172  
10008487  
10008487  
10006382  
7554338  
10006532  
--  
10004262  
10001393  
--  
10007664  
10004584  
10004262  
10001393  
10002987  
10004695  
10004720  
10001639  
10007443  
10006391  
10007667  
10004847  
10007673  
10007666  
10006453  
10001172  
10008487  
10008487  
10006382  
7554340  
10007664  
--  
10004262  
10001393  
--  
3. Motor, AC, w/Terminals  
4. Rocker Switch (Illuminated)  
5. Thermostat - Heater Control  
6. Fan w/Bracket Assembly  
7. Sensor, 230°F Manual Reset  
8. Knob - Heater Controls  
9. Plate Control Assembly  
10. Screen Tinted Plastic (Not Shown)  
11. Ember Lava Rock  
12. Flame Generator Assembly  
13. Support Plate  
14. Plate Log Support Assembly  
15. Socket Light Bulb Lower Assembly  
16. Limit Control, 175/20 DIF  
17. Transmitter  
--  
--  
--  
--  
--  
--  
--  
--  
--  
10007830  
10007612  
10007461  
10003350  
10007434  
10007447  
10006453  
--  
10007608  
10007430  
10007461  
10003350  
10007434  
10007447  
10006453  
--  
10007608  
10006391  
10007667  
10004847  
10007673  
10007666  
10006453  
--  
--  
--  
--  
--  
--  
--  
18. Receiver  
19. CFM Wire Req'd (not shown)  
20. Screen Assembly  
21. Screen Rod  
22. One Piece Screen Pull (2 per Fireplace) 7554239  
23. Cable Clip (4 per Fireplace) 7512135  
10007639  
7554299  
3993138  
7554239  
7512135  
10007639  
7554338  
10007433  
7554239  
7512135  
10007639  
7554340  
10007433  
7554239  
7512135  
3993138  
10007433  
7554239  
7512135  
10007433  
7554239  
7512135  
NOTE: Items 17 and 18 (Transmitter and Receiver) must be replaced as a set.  
Accessories  
The following accessories for these appliances are  
available from your local CFM Specialty Home Products  
distributor.  
See your CFM Specialty Home Products distributor or  
dealer for other finishing options, such as marble and  
mantels that are available in a wide selection of styles.  
NOTE: Each accessory comes with a separate in-  
stallation instruction for mounting to the particular  
appliance. Be sure to read each instruction thor-  
oughly before installing.  
Accessory  
Description  
Model Number  
Thermostat  
Power Cord  
Refractory Kit  
(not available for  
units with ceramic  
log set)  
Wall Thermostat, electric fireplace  
EBWT  
10003095  
BREF30RK  
BREF36RK  
BREF42RK  
Refractory panels give the appliance  
a realistic brick look  
Bi-fold Glass Doors Glass doors enhance the viewing area Brushed Brass - 30GDKBB, 36GDKBB, 42GDKBB  
of the fireplace  
Black - 30GDKBK, 36GDKBK, 42GDKBK  
Polished Brass - 30GDKDP, 36GDKDP, 42GDKDP  
Pewter - 30GDKS, 36GDKS, 42GDKS  
20  
10004758  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
10004758  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BREF Electric Fireplace  
22  
10004758  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 YEAR WARRANTY  
For MAJESTIC FIREPLACES® Electric Fireplaces  
GARANTIE DE BASE:  
BASIC WARRANTY:  
CFM Specialty Home Products (hereinafter referred to  
collectively as the "Company") warrants that your new  
Majestic Fireplaces® fireplace is free from manufacturing  
and material defects for a period of one year from date of  
installation, subject to the following conditions and limitations.  
CFM Specialty Home Products (aux présentes nommée la  
"Société") garantit votre nouveau foyer électrique Majestic  
Fireplaces® contre tous défauts de fabrication et de matières  
premières pour une période d'un an à compter de la date  
d'installation, sujet aux conditions et limitations suivantes.  
1. Le foyer electrique doit être installé par un entrepreneur de  
service autorisé et compétent. Il doit être installé et utilisé  
en tout temps selon les instructions d'installation et de  
fonctionnement fournies avec le produit. Toute altération,  
abus volontaire, accident ou mauvais usage du produit  
annulera cette garantie.  
2. Cette garantie n'est pas transférable et est offerte à l'acheteur  
au détail d'origine, à condition que l'achat soit effectué par  
l'entremise d'un détaillant autorisé de la Société.  
3. Cette garantie est limitée à la réparation ou au remplacement  
de(des) pièce(s) trouvée(s) défectueuse(s) en matières  
premières ou main-d'oeuvre, à condition que lesdites  
pièces aient été sujettes aux conditions normales d'usage  
et de service, après que ledit défaut a été confirmé par une  
inspection par la Société.  
1. This electric fireplace must be installed and operated at  
all times in accordance with the Installation and Operating  
instructions furnished with the product. Any alteration, willful  
abuse, accident, or misuse of the product shall nullify this  
warranty.  
2. This warranty is non-transferrable, and is made to the original  
owner, provided that the purchase was made through an  
authorized supplier of the Company.  
3. This warranty is limited to the repair or replacement of part(s)  
found to be defective in material or workmanship, provided that  
such part(s) have been subjected to normal conditions of use  
and service, after said defect is confirmed by the Company's  
inspection.  
4. This warranty does not cover the lightbulb(s) included with  
the fireplace  
.
4. Cette Garantie ne couvre pas les ampoules inclus dans le  
foyer électrique.  
5. The Company may, at its discretion, fully discharge all  
obligations with respect to this warranty by refunding the  
wholesale price of the defective part(s).  
6. Any installation, labour, construction, transportation, or other  
related costs/expenses arising from defective part(s), repair,  
replacement, or otherwise of same, will not be covered by  
this warranty, nor shall the Company assume responsibility  
for same. Further, the Company will not be responsible for  
any incidental, indirect, or consequential damages, except as  
provided by law.  
7. All other warranties - expressed or implied - with respect to the  
product, its components and accessories, or any obligations/  
liabilities on the part of the Company are hereby expressly  
excluded.  
8. The Company neither assumes, nor authorizes any third party  
to assume, on its behalf, any other liabilities with respect to the  
sale of this Majestic Fireplaces product.  
5. La Société peut, à sa discrétion, se décharger entièrement  
de toutes obligations se rapportant à cette garantie en  
remboursant le prix de gros de la(des) pièce(s) défectueuse(s).  
6. Tous les frais/dépenses d'installation, de main-d'oeuvre, de  
construction, de transport ou autres causés par une (des)  
pièce(s) défectueuse(s), une réparation, un remplacement ou  
autre, ne seront pas couverts sous cette garantie, et la Société  
n'assume aucune responsabilité pour ceux-ci. De plus, la  
Société ne pourra être tenue responsable pour tous dommages  
fortuits ou indirects sauf la ou prévu par la loi.  
7. Toutes autres garanties, exprimées ou sous-entendues, en ce  
qui a trait au produit, ses composants et accessiores, ou toutes  
obligations/responsabilités de la part de la Société sont aux  
présentes expressment excluses.  
8. La Société n'assume et n'autorise personne à assumer, en son  
nom, toutes responsabilités en ce qui a trait à la vente de ce  
9. The warranties as outlined within this document do not apply  
to non CFM Specialty Home Products accessories used in  
conjunction with the installation of this product.  
This warranty is void if:  
produit Majestic Fireplaces  
.
9. Les garanties, telles que décrites dans ce document, ne  
s'appliquent accessoires non CFM Specialty Home Products  
utilisés conjointement pour l'installation de ce produit.  
10. Cette garantie est nulle si:  
a) The fireplace has been operated in atmospheres  
contaminated by chlorine, fluorine or other damaging  
chemicals.  
b) The fireplace is subjected to prolonged periods of  
dampness or condensation.  
a) Le foyer a été utilisé dans une atmosphère contaminée  
par du chlore, du fluor ou tous autres produits chimiques.  
b) Le foyer est assujetti à de longues périodes d'humidité ou  
de condensation.  
c) Toute altération, abus volontaire, accident ou mauvais  
usage du produit annulera cette garantie.  
c) Any alteration, willful abuse, accident, or misuse of the  
product.  
GLASS DOORS & BRASS PLATED PARTS . . .  
Glass doors are not warranted for breakage due to misuse or  
accident.  
Brass parts should be cleaned with lemon oil only. Brass cleaners  
cannot be used. Mortar mix and masonry cleaners may corrode  
the brass finish. The Company will not be responsible for, nor will it  
warrant any brass parts which are damaged by external chemicals.  
PORTES EN VERRE & PIECES PLAQUEES LAITON . . .  
Les portes en verre ne sont pas garanties contre le bris causé par  
un mauvais usage ou un accident.  
Les pièces en laiton devraient être nettoyées qu'avec de l'essence  
de citron. Les nettoyeurs de laiton ne peuvent pas être utilisés. La  
Société ne sera pas responsable pour, et ne garantit pas les pièces  
en laiton qui sont endommagées par de refoulement.  
IF WARRANTY SERVICE IS NEEDED . . .  
SI UN SERVICE SOUS GARANTIE EST REQUIS . . .  
1) Communiquez avec votre détaillant. Assurez-vous que vous  
avez votre garantie, votre reçu de caisse ainsi que le numéro  
de modèle/série de votre produit CFM Specialty Home  
Products.  
1) Contact your supplier. Make sure you have your warranty,  
your sales receipt, and the model/serial number of your CFM  
Specialty Home Products product.  
2) DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.  
2) NE TENTEZ PAS D'EFFECTUER DES REPARATIONS  
VOUS-MEME.  
10004758  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CFM Specialty Home Products  
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Telex Intercom System WM1000 User Manual
Timex Watch W 102 User Manual
Toshiba CRT Television 27AF62 User Manual
Toshiba Personal Computer SATELLITE PRO A120 User Manual
TRENDnet Switch TK803R User Manual
ViewSonic Computer Monitor VS12939 User Manual
ViewSonic Flat Panel Television Q19wb 2 User Manual
Vulcan Hart Fryer ML 114826 User Manual
Wacom Tablet CTL470 User Manual
Weber Gas Grill 55767 User Manual